36C24418B0288-005.pdf
PDF 16 MB Posted
- Attached to
- Renovate Specialty Clinics #642-16-106
- Solicitation number
- 36C24418B0288
About this file
36C24418B0288 Drawings 29-34.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24418C0183-000.docx | DOCX document | |
| 36C24418B0288-00002000.docx | DOCX document | |
| 36C24418B0288-00002001.pdf | ||
| 36C24418B0288-00001000.docx | DOCX document | |
| 36C24418B0288-00001001.pdf | ||
| 36C24418B0288-001.docx | DOCX document | |
| 36C24418B0288-006.pdf | ||
| 36C24418B0288-002.pdf | ||
| 36C24418B0288-003.pdf | ||
| 36C24418B0288-004.pdf | ||
| 36C24418B0288-007.pdf | ||
| 36C24418B0288-000.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LUMINAIRE SUSPENSION
WIRES (#10 MIN)
ATTACHED TO
STRUCTURE
(TYP EA. CORNER)
3 TWIST MINIMUM
(TYP)
FIXTURE WHIP FROM
JUNCTION BOX
(6FT. LONG MAX.)
LUMINAIRE.
REFER TO
SCHEDULE
LUMINAIRE MANUFACTURER'S
EARTHQUAKE CLIP, (4) PER FIXTURE
AT CORNERS. ATTACH WITH SHEET
METAL SCREW
ACOUSTICAL CEILING
TILE (TYP)
ARCHITECTURAL
CEILING GRID
LUMINAIRE.
REFER TO
SCHEDULE
CEILING HANGER
WIRE, TYP.
RECESSED CAN
LUMINAIRE
ARCHITECTURAL
CEILING GRID
WIRE TIE OR SCREW
BAR HANGER TO
ARCHITECTURAL
CEILING GRID TYP.
LUMINAIRE
BAR HANGERS
12GA. HANGER WIRE AT DIAGONAL
CORNER ATTACHED TO STRUCTURE
ACOUSTICAL
CEILING TILE (TYP)
RECESSED CAN
LUMINAIRE
ARCHITECUTRAL
CEILING GRID
CEILING HANGER WIRE
ARCHITECTURAL
CEILING GRID
ARCHITECTURAL
CEILING GRID
ACOUSTICAL
CEILING
TILE (TYP)
#12 GA. HANGER WIRE THROUGH INTEGRAL
GALVANIZED LIPPED STEEL MOUNTING
CHANNEL & ATTACHED TO STRUCTURE
INTEGRAL GALVANIZED LIPPED
STEEL MOUNTING CHANNEL
JUNCTION BOX
LOCKING SQUARE
WASHER & NUT
1/4" SCREW
ARCHITECTURAL
CEILING GRID
WIRE TIE THROUGH
MOUNTING CHANNEL &
CROSS BEAM, TYP.
CONDUIT, TYP MINERAL WOOL
(FIRMLY PACKED)
FIRESTOP SEALANT
PER SECTION 07 84 00,
FIRESTOPPING
3/8" MAX
JUNCTION BOX
(SIZE AS REQUIRED)
CONDUIT COMPRESSION
FITTING, TYP.
SPRING
NUT, TYP
INTEGRAL GALVANIZED
LIPPED STEAL MOUNTING
CHANNEL, TYP.
FLOOR SLAB,
TYP.
STEEL EXPANSION
ANCHOR, TYP
NOTES:
FOR VOICE JACKS, PROVIDE ONE (1) 4 PAIR, 24
AWG, UNSHIELDED TWISTED PAIR, CATEGORY
5e CABLE. SPLIT THE 4 PAIRS BETWEEN THE
TWO VOICE JACKS; WHITE/BLUE AND WHITE/
ORANGE PAIRS TERMINATE TO THE TOP JACK,
WHITE/GREEN AND WHITE/BROWN PAIRS
TERMINATE TO THE BOTTOM JACK. CABLING
SHALL BE PROVIDED WITH WHITE OUTER
JACKET
1.
NOTES:
OUTLETS
TELEPHONE
DATA AND
MTD 18" AFF BY EC.
RING RECESSED IN WALL,
4"x 4"x 2 1/2" BACKBOX
W/ SINGLE GANG PLASTER
FLOOR
FINISH CEILING
DATA/PHONE CABLING, BY EC. PROVIDE CABLE
FROM USER JACKS TO TELECOM CLOSET 5B118
VIA NEW WIREWAY. ONCE IN TELECOM ROOM,
PROVIDE 20' OF SLACK CABLING, COILED FOR
ORGANIZING PURPOSES, TO ALLOW EXTENSION
AND TERMINATION OF CABLING, TERMINATIONS
DONE UNDER OTHER CONTRACTS.
REMOVABLE
TYPE CEILING
PROVIDE 1" CONDUIT
TO NEW WIREWAY
SINGLE GANG PLASTER RING BY EC
CATEGORY 5e COMPLIMENT, EIGHT POSITION, RJ-45
NON-KEYED COMMUNICATIONS
OUTLETS (TYPICAL OF FOUR)
OUTLET
NAMEPLATE
LABEL (TYP)
SINGLE GANG PLASTIC
FACEPLATE
JACKS DESIGNATED
FOR VOICE SHALL BE
WHITE IN COLOR WITH
VOICE ICON
UNLESS NOTED OTHERWISE ON THE DRAWINGS, THIS DETAIL APPLIES TO THE SYMBOL
SHOWN ON THE FLOOR PLANS.
DETAIL IS FOR DIAGRAMMATICAL AND
BIDDING PURPOSES ONLY. FIXTURE(S)
SHALL BE INSTALLED AS PER
MANUFACTURERS RECOMMENDATIONS
NOTE:
DETAIL IS FOR DIAGRAMMATICAL AND
BIDDING PURPOSES ONLY. FIXTURE(S)
SHALL BE INSTALLED AS PER
MANUFACTURERS RECOMMENDATIONS
NOTE:
DETAIL IS FOR DIAGRAMMATICAL AND
BIDDING PURPOSES ONLY. FIXTURE(S)
SHALL BE INSTALLED AS PER
MANUFACTURERS RECOMMENDATIONS
NOTE:
1" CONCEALED
CONDUIT BY EC
4"x4"x2-1/2"D OUTLET
BOX BY EC
THREE (3) CATEGORY 5e
CABLING BY EC
TO EACH DATA JACK PROVIDE 4 PAIR,
24 AWG, UNSHIELDED TWISTED PAIR,
CATEGORY 5e CABLES FOR DATA
OUTLETS. CABLING SHALL BE
PROVIDED WITH BLUE OUTER JACKET
8 POSITION, 8 CONDUCTOR,
NON-KEYED RJ-45 CATEGORY
5e JACK BY EC
(TYPICAL OF FOUR SHOWN)
1" CONDUIT BY EC, PROVIDE NEW
CABLING IN RACEWAY FOR ENTIRE
RUN TO TELECOM CLOSET
1. THIS DETAIL APPLIES TO THE SYMBOL SHOWN ON
THE FLOOR PLANS.
2. ALL DATA WIRING SHALL BE INSTALLED IN ACCORDANCE
WITH APPLICABLE CODES AND STANDARDS.
3. ALL DATA WIRING SHALL BE INSTALLED BY A CERTIFIED
INSTALLER.
4. THIS DETAIL IS INTENDED TO ILLUSTRATE THE INTENT OF
THE DATA HORIZONTAL WIRING AND DATA OUTLET
CONFIGURATION ONLY, ACTUAL REQUIREMENTS AND
CONDITIONS MAY VARY. IT SHALL BE THE
RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO
VERIFY SITE CONDITIONS & COORDINATE INSTALLATION
REQUIREMENTS WITH OWNER & ARCHITECT.
5. COORDINATE EXACT INFORMATION OUTLET LOCATION
WITH PLANNED FURNITURE LAYOUT.
6. AT FACEPLATE VOICE JACKS, SPLIT CATEGORY 5e CABLE
SHALL TERMINATE AS FOLLOWS. ON TOP JACK,
WHITE/BLUE PAIR SHALL TERMINATE AT WHITE/BLUE PINS
AND WHITE/ORANGE SHALL TERMINATE AT WHITE/GREEN
PINS. AT BOTTOM JACK, WHITE/GREEN PAIR SHALL
TERMINATE AT WHITE/BLUE PINS AND WHITE/BROWN
PAIR SHALL TERMINATE AT WHITE/GREEN PINS.
7. DATA AND VOICE CABLING SHALL BE TERMINATED AT
DATA JACKS FOLLOWING PIN PAIR ASSIGNMENTS OF
EIA/TIA STANDARD T568A AND 606.
JACKS DESIGNATED
FOR DATA SHALL BE
ORANGE IN COLOR
WITH DATA ICON
FLOOR SLAB PENETRATION DETAIL
NOT TO SCALE
LUMINAIRE MOUNTING - LAY-IN CEILING
NOT TO SCALE
DOWNLIGHT MOUNTING - LAY-IN CEILING
NOT TO SCALE
COMBINATION DATA/TELEPHONE OUTLET AND FACEPLATE DETAIL
NOT TO SCALE
EXIT SIGN MOUNTING - LAY-IN CEILING
NOT TO SCALE
COMBINATION DATA/TELEPHONE OUTLET ELEVATION
NOT TO SCALE
NOTES:
SINGLE GANG PLASTER RING BY EC
JACKS SHALL BE ORANGE IN
COLOR WITH DATA ICON;
CATEGORY 5e COMPLIMENT, EIGHT POSITION, RJ-45
NON-KEYED COMMUNICATIONS
OUTLETS
OUTLET
NAMEPLATE
LABEL (TYP)
SINGLE GANG PLASTIC
FACEPLATE
4"x4"x2-1/2"D OUTLET
BOX BY EC
ONE (1) CATEGORY 5e
CABLING BY EC
TO EACH DATA JACK/VOICE JACK PROVIDE 4
PAIR, 24 AWG, UNSHIELDED TWISTED PAIR,
CATEGORY 5e CABLES FOR DATA/VOICE
OUTLETS. CABLING SHALL BE PROVIDED WITH
BLUE OUTER JACKET
8 POSITION, 8 CONDUCTOR,
NON-KEYED RJ-45 CATEGORY
5e JACK BY EC
1" CONDUIT TO ABOVE
CEILING WIREWAY BY EC
1. THIS DETAIL APPLIES TO THE SYMBOLS , ,
SHOWN ON THE FLOOR PLANS.
2. ALL DATA WIRING SHALL BE INSTALLED IN ACCORDANCE
WITH APPLICABLE CODES AND STANDARDS.
3. ALL DATA WIRING SHALL BE INSTALLED BY A CERTIFIED
INSTALLER.
4. THIS DETAIL IS INTENDED TO ILLUSTRATE THE INTENT OF
THE DATA HORIZONTAL WIRING AND DATA OUTLET
CONFIGURATION ONLY, ACTUAL REQUIREMENTS AND
CONDITIONS MAY VARY. IT SHALL BE THE
RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO
VERIFY SITE CONDITIONS & COORDINATE INSTALLATION
REQUIREMENTS WITH OWNER & ARCHITECT.
5. COORDINATE EXACT INFORMATION OUTLET LOCATION
WITH PLANNED FURNITURE LAYOUT.
6. DATA AND VOICE CABLING SHALL BE TERMINATED AT
DATA JACKS FOLLOWING PIN PAIR ASSIGNMENTS OF
EIA/TIA STANDARD T568A AND 606.
SINGLE OUTLET COMMUNICATIONS DETAIL
NOT TO SCALE
WAP W
1.
NOTES:
WITH CEILING BY EC.
RING MOUNTED FLUSH
4"x 4"x 2 1/2" BACKBOX
W/ SINGLE GANG PLASTER
FLOOR
FINISH CEILING
DATA/PHONE CABLING, BY EC. PROVIDE CABLE
FROM USER JACKS TO TELECOM CLOSET 5B118
VIA NEW WIREWAY. ONCE IN TELECOM ROOM,
PROVIDE 20' OF SLACK CABLING, COILED FOR
ORGANIZING PURPOSES, TO ALLOW EXTENSION
AND TERMINATION OF CABLING, TERMINATIONS
DONE UNDER OTHER CONTRACTS.
REMOVABLE
TYPE CEILING
UNLESS NOTED OTHERWISE ON THE DRAWINGS, THIS DETAIL APPLIES TO THE SYMBOL
SHOWN ON THE FLOOR PLANS.
WIRELESS ACCESS POINT DATA OUTLET ELEVATION
NOT TO SCALE
WAP
1"C. BY EC
PROVIDE 1" CONDUIT
TO NEW WIREWAY
TOP
FRONT SIDE
ISOMETRIC
NOTE:
TRAY DESIGNED PER NEMA VE-1 CSA C22.2 No. 126
WIRE BASKET CABLE TRAY DETAIL
NOT TO SCALE
TV
THIS DETAIL APPLIES TO THE SYMBOL SHOWN
ON THE FLOOR PLANS.
NOTES:
1.
REMOVABLE TYPE
CEILING
FLOOR
FINISH CEILING
POWER DUPLEX
RECEPTACLE
V
T
COAX TV CABLING BY
CABLE INSTALLER
ROUTE 1"C TO AND TERMINATE AT
CLOSET HOUSING CABLE TV TAP PANEL,
SEE DRAWING FOR LOCATION OF CLOSET
2.
EC SHALL PROVIDE ALL OUTLET BOXES,
RACEWAYS, TELEVISION CABLING, AMPS, TAP
PANELS AS NECESSARY.
WITH PULLCORD BY EC
1" CONCEALED CONDUIT
4"x 4"x 2 1/2" BACKBOX BY
EC W/ SINGLE GANG
PLASTER RING RECESSED
IN WALL, MTD 12" BELOW
CEILING OR 18" AFF,
COORDINATE W/
ARCHITECT
TELEVISION WALL OUTLET ELEVATION
NOT TO SCALE
NEW WIREWAY
NEW WIREWAY NEW WIREWAY
2000 Market Street
Philadelphia, PA 19103
Fax (215) 568-2639
Tel (215) 568-8250
F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue
H.F. Lenz Company
Mechanical, Electrical, Fire Protection, and Plumbing Engineer
"FULLY SPRINKLERED BUILDING"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Construction and Facilities
Management on e e igh th inc h = on e f oo t
B
A
C
D
E
F thr ee in ch es on e f oo t
6"
6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t
6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Suite 600
SEAL:
P M
05-JAN-2018
ES401
3900 Woodland Ave, Philadelphia, PA 19104
KEY PLAN
N
TME
RENOVATE
SPECIALTY CLINICS
642-16-106
ELECTRICAL DETAILS
RJD
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
AutoCAD SHX Text
NOTES:
1. SEQUENCE OF OPERATION: IN THIS CONFIGURATION, THE
SINGLE RELAY CONTROLLER DEFAULTS TO MANUAL -
ON/AUTOMATIC OFF. MAXIMUM OF 4 ROOM CONTROLLERS,
CONTROLLING UP TO 8 LOADS.
UNSWITCHED
HOT BLK
120/277
NEUTRAL WHT
WHITE
RED
ISOLATED RELAY INTERFACE
OCCUPANCY SENSOR
COUPLER (IF REQUIRED)
RJ45 (TYPICAL)
LOW VOLTAGE SWITCH
LOW VOLTAGE SWITCH
(AS NEEDED)
SIGNAL FOR ROOM
HVAC CONTROL
CAT 5e
CABLES
(TYPICAL)
CAT 5e
CABLES
(TYPICAL)
CAT 5e
CABLES
(TYPICAL)
SINGLE RELAY ON/OFF
ROOM CONTROLLER
LIGHTING LOAD
NOTES:
1. SEQUENCE OF OPERATION: IN THIS CONFIGURATION, THE
DUAL-RELAY CONTROLLER DEFAULTS TO MULTI-LEVEL
AUTOMATICALLY-ON/AUTOMATIC OFF. LOAD (a) TURNS
AUTOMATICALLY ON AUTOMATICALLY AND LOAD (b)
DEFAULTS TO MANUAL-ON CONTROL; BOTH LOADS TURN
AUTOMATICALLY OFF. MAXIMUM OF 4 ROOM CONTROLLERS,
CONTROLLING UP TO 8 LOADS.
UNSWITCHED
HOT BLK
120/277
NEUTRAL WHT
WHITE
RED
ISOLATED RELAY INTERFACE
OCCUPANCY SENSOR
COUPLER (IF REQUIRED)
RJ45 (TYPICAL)
LOW VOLTAGE SWITCH
LOW VOLTAGE SWITCH
(AS NEEDED)
SIGNAL FOR ROOM HVAC CONTROL
CAT 6
CABLES
(TYPICAL)
CAT 6
CABLES
(TYPICAL)
CAT 6
CABLES
(TYPICAL)
DUAL RELAY ON/OFF
ROOM CONTROLLER
LIGHTING LOAD (a)
YELLOW
LIGHTING LOAD (a)
NOTES:
1. SEQUENCE OF OPERATION: IN THIS CONFIGURATION, THE
DUAL-RELAY CONTROLLER DEFAULTS TO MULTI-LEVEL
AUTOMATIC-ON/AUTOMATIC OFF WITH DIMMING OF ALL LOADS.
LOAD (a) TURNS ON AUTOMATICALLY AND LOAD (b) DEFAULTS TO
MANUAL-ON CONTROL; BOTH LOADS TURN AUTOMATICALLY OFF.
MAXIMUM OF 4 ROOM CONTROLLERS, CONTROLLING UP TO 8
LOADS. DEFAULT DIMMING PARAMETERS ARE ESTABLISHED
INCLUDING: LEVELS FOR PRESETS 1-4; FADE TIMES; AND FADE
AND RAMP RATES. DIMMING AND SYSTEM PARAMETERS MAY
BE CUSTOMIZED.
SIGNAL FOR
ROOM HVAC
CONTROL
CLASS 2 0-10 VOLT
CONTROL WIRING
ISOLATED RELAY INTERFACE
RED
YEL
VIO
GRY
VIO
GRY
DUAL RELAY
ON/OFF/0-110V DIMMING
ROOM CONTROLLER
NEUTRAL WHT
UNSWITCHED
HOT BLK
120/277
DIGITAL
5-BUTTON SCENE
SWITCH
OCCUPANCY SENSOR AND/OR
DAYLIGHTING SENSOR
COUPLER (IF REQUIRED)
CAT 6 CABLE
CAT 6 CABLE
CAT 6 CABLE
V I O
G R
Y
V I O
G R
Y
LIGHTING
LOAD (a)
LIGHTING
LOAD (b)
BLUE LOAD
STATUS LED(S)
ON
TWO (2) RJ45
CONNECTORS
OFF
RED CONFIGURATION
LED
SINGLE BUTTON DIGITAL
SWITCH
1. THIS DETAIL APPLIES WHERE OR IS SHOWN ON THE PLANS.
2. PROVIDE MANUFACTURER RECOMMENDATION LABELING ON
SWITCHES TO DENOTE THE FUNCTION OF THE SWITCH.
NOTES:
L1
BLUE LOAD
STATUS LED(S)
ON/RAISE
TWO (2) RJ45
CONNECTORS
OFF/LOWER
RED CONFIGURATION
LED
SINGLE BUTTON DIGITAL
DIMMER SWITCH
1. THIS DETAIL APPLIES WHERE OR IS SHOWN ON THE PLANS.
2. PROVIDE MANUFACTURER RECOMMENDATION LABELING ON
SWITCHES TO DENOTE THE FUNCTION OF THE SWITCH.
NOTES:
LED DIMMING LEVEL
INDICATOR
L1
D
BLUE LOAD
STATUS LED(S)
ON/OFF/LOAD A ON-OFF
TWO (2) RJ45
CONNECTORS
ON/OFF/LOAD B ON-OFF
RED CONFIGURATION
LED
TWO BUTTON DIGITAL
SWITCH
1. THIS DETAIL APPLIES WHERE OR IS SHOWN ON THE PLANS.
2. PROVIDE MANUFACTURER RECOMMENDATION LABELING ON SWITCHES
TO DENOTE THE FUNCTION OF THE SWITCH.
NOTES:
L2 ab
L2
SINGLE RELAY ROOM LIGHTING CONTROL DIAGRAM
NOT TO SCALE
DOUBLE RELAY ROOM LIGHTING CONTROL DIAGRAM
NOT TO SCALE
DIMMING RELAY ROOM LIGHTING CONTROL DIAGRAM
NOT TO SCALE
SINGLE BUTTON WALL SWITCH
NOT TO SCALE
SINGLE BUTTON WALL SWITCH W/ DIMMING
NOT TO SCALE
TWO BUTTON WALL SWITCH
NOT TO SCALE
WALL SWITCH SENSOR
GREEN
BLACK
LOAD
BLACK
H
N
W/ DUAL TECHNOLOGY
WALL SWITCH SENSOR
GREEN
BLACK
LOAD
BLACK
H
N
W/ DUAL TECHNOLOGY
LINE VOLTAGE WALL SWITCH SENSOR
NOT TO SCALE
AND ON/OFF SWITCH
LINE VOLTAGE DIMMER WALL SWITCH SENSOR
NOT TO SCALE
ON/OFF ROCKER SWITCH
AND 0-10V SLIDE DIMMER
JUNCTION
BOX,
SIZE AS
NEEDED
IAM
J
FINISHED CEILING
3/4"CONDUIT WITH
NYLON PULLCORD
2 #14 - 3/4"CONDUIT
PROVIDE RECESSED 4"x4"
OUTLET BOX MOUNTED ON
ENTRANCE SIDE OF DOOR
FOR SECURITY CARD READER.
CONDUIT FOR ELECTRIC STRIKE.
PROVIDE CONDUIT TO DOOR FRAME,
CAP WITH INSULATED BUSHING.
CONDUIT FOR DOOR CONTACT.
PROVIDE CONDUIT TO DOOR
FRAME, CAP WITH INSULATED
BUSHING
REQUEST TO EXIT MOUNTED ON
EGRESS SIDE OF DOOR. PROVIDE
CONDUIT TO DOOR FRAME, CAP
WITH INSULATED BUSHING
TO FIRE ALARM CONTROL PANEL. DOOR SHALL
UNLOCK UPON ACTIVATION OF FIRE ALARM
SYSTEM ON FLOOR.
FINISHED FLOOR
1. THIS DETAIL APPLIES TO SECURE, SINGLE DOOR
LOCATIONS FLOOR PLANS.
2. COORDINATE FINAL LOCATION OF BOXES WITH
ARCHITECT BEFORE PERFORMING ROUGH-INS.
3. DETAIL SHOWS TYPICAL ARRANGEMENT OF
RACEWAYS AND BOXES REQUIRED FOR EC
PROVIDED DOOR ACCESS EQUIPMENT, REFER TO THE
DRAWINGS FOR ANY SPECIFIC LOCATIONS OF DEVICES.
4. EC SHALL PROVIDE COMPLETE DOOR ACCESS
SYSTEM. SEE PHASE 1 PACS DRAWING FOR MROE
INFORMATION.
NOTES:
J
PROVIDE RECESSED 4"x4" OUTLET
BOX MOUNTED ON EGRESS SIDE
OF DOOR FOR REQUEST TO EXIT
DEVICE.
SINGLE SECURE DOOR ELEVATION DETAIL
NOT TO SCALE
2000 Market Street
Philadelphia, PA 19103
Fax (215) 568-2639
Tel (215) 568-8250
F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue
H.F. Lenz Company
Mechanical, Electrical, Fire Protection, and Plumbing Engineer
"FULLY SPRINKLERED BUILDING"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Construction and Facilities
Management on e e igh th inc h = on e f oo t
B
A
C
D
E
F thr ee in ch es on e f oo t
6"
6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t
6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Suite 600
SEAL:
P M
05-JAN-2018
ES402
3900 Woodland Ave, Philadelphia, PA 19104
KEY PLAN
N
TME
RENOVATE
SPECIALTY CLINICS
642-16-106
ELECTRICAL DETAILS
RJD
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
1ST FLOOR
PIPE BASEMENT
EXISTING SUBSTATION No.3
480/277V
EXISTING
EMERGENCY
LIFE
SAFETY
PANEL
'DEL2'
480/277V
225A MCB
BASEMENT
2ND FLOOR
3RD FLOOR
4TH FLOOR
5TH FLOOR
6TH FLOOR
7TH FLOOR
8TH FLOOR
9TH FLOOR
10'
12'
12'
12'
12'
12'
12'
12'
EXISTING
EMERGENCY
CRITICAL
PANEL
'DEC2'
208/120V
800A MCB
12'
EXISTING
EMERGENCY
CRITICAL
PANEL
'EC5A'
208/120V
EXISTING
EMERGENCY
LIFE
SAFETY
PANEL
'EL7B'
480/277V
EXISTING
EMERGENCY
LIFE
SAFETY
PANEL
'EL8B'
480/277V
EXISTING
EMERGENCY
CRITICAL
PANEL
'EC8A'
208/120V
EXISTING
EMERGENCY
CRITICAL
PANEL
'DEC3'
480/277V
800A MCB
EXISTING
EMERGENCY
CRITICAL
PANEL
'EC7H'
480/277V
EXISTING
EMERGENCY
CRITICAL
PANEL
'EC8H'
480/277V
EXISTING
NORMAL
POWER
PANEL
'7SHA'
480/277V
EX. 112.5kVA
TRANSFORMER
PRI - 480V
SEC - 208/120V
EXISTING
NORMAL
POWER
PANEL
'7SL'
208/120V
EXISTING
NORMAL
POWER
PANEL
'7SLA'
208/120V
EX. 75kVA
TRANSFORMER
PRI - 480V
SEC - 208/120V
EXISTING
NORMAL
POWER
PANEL
'7NL'
208/120V
EXISTING
NORMAL
POWER
PANEL
'7NLA'
208/120V
EXISTING
NORMAL
POWER
PANEL
'8SHA'
480/277V
EXISTING
NORMAL
POWER
PANEL
'8SLA'
208/120V
EXISTING
NORMAL
POWER
PANEL
'8NLA'
208/120V
EXISTING
NORMAL
POWER
PANEL
'5SHA'
480/277V
EXISTING
NORMAL
POWER
PANEL
'5SLA'
208/120V
EXISTING
NORMAL
POWER
PANEL
'5NLA'
208/120V
EXISTING
NORMAL
POWER
PANEL
'7EHA'
480/277V
EX. 75kVA
TRANSFORMER
PRI - 480V
SEC - 208/120V
EXISTING
NORMAL
POWER
PANEL
'7EL'
208/120V
EXISTING
NORMAL
POWER
PANEL
'7ELA'
208/120V
EX. 45kVA
TRANSFORMER
PRI - 480V
SEC - 208/120V
EXISTING
NORMAL
POWER
PANEL
'7ELB'
208/120V
EXISTING
NORMAL
POWER
PANEL
'8EHA'
480/277V
EXISTING
NORMAL
POWER
PANEL
'8ELA'
208/120V
EXISTING
NORMAL
POWER
PANEL
'8ELB'
208/120V
EXISTING
NORMAL
POWER
PANEL
'5EHA'
480/277V
EXISTING
NORMAL
POWER
PANEL
'5ELA'
208/120V
EXISTING
NORMAL
POWER
PANEL
'5ELB'
208/120V
NEW
NORMAL
POWER
PANEL
'8ELB'
100A MCB
225A BUS
208/120V
KEYNOTES ELSEWHERE THIS DRAWING:
NEW PANEL(S) SHALL BE PROVIDED IN SAME LOCATION AS DEMOLISHED PANEL. RECONNECT
EXISTING FEEDERS TO PANEL AND EXISTING BRANCH CIRCUITS TO BREAKERS PROVIDED IN PANEL.
NEW
NORMAL
POWER
PANEL
'8ELA'
100A MCB
225A BUS
208/120V
EXISTING SUBSTATION No.1
480/277V
DISCONNECT EXISTING FEEDER FROM EXISTING PANEL. DEMOLISH EXISTING PANEL AS SHOWN, PROVIDE JUNCTION BOXES FOR EXISTING BRANCH CIRCUITS THAT ARE TO REMAIN, CIRCUITS SHALL
BE RE-CONNECTED TO NEW PANEL. FEEDER SHALL REMAIN FOR RE-CONNECTION TO NEW PANEL.
EXISTING SUBSTATION No.4
480/277V
EXISTING
NORMAL
POWER
PANEL
'PNDP'
480/277V
EXISTING
NORMAL
POWER
PANEL
'PN'
480/277V
EXISTING
NORMAL
POWER
PANEL
'PN1'
480/277V
EXISTING
NORMAL
POWER
PANEL
'PN2'
480/277V
EXISTING
NORMAL
POWER
PANEL
'PN3'
480/277V
EX. 45kVA
TRANSFORMER
PRI - 480V
SEC - 208/120V
EXISTING
NORMAL
POWER
PANEL
'PNA'
208/120V
EXISTING
NORMAL
POWER
PANEL
'PNA1'
208/120V
EXISTING
EMERGENCY
LIFE
SAFETY
PANEL
'EL8B1'
208/120V
EX. 37.5kVA
TRANSFORMER
PRI - 480V
SEC - 208/120V
GENERAL ELECTRICAL NOTES THIS DRAWING:
1. REPLACEMENT OF PANELS SHALL OCCUR OVER WEEKENDS OR OFF-HOUR SHIFTS TO MINIMIZE
DOWN TIME FOR SECTIONS OF FLOOR UN-AFFECTED BY CURRENT PHASE OF CONSTRUCTION.
2. FOR PANELS SHOWN AS DEMOLISHED, REFER TO PANEL SCHEDULES ON DRAWINGS E-601 &
E-602 FOR EXISTING BRANCH CIRCUITS THAT ARE TO REMAIN AND BE RE-CONNECTED TO NEW
PANEL(S)
1 #10 GRD. IN 3/4"C. FROM NORMAL POWER
PANEL GROUND BUS TO
NORMAL/EMERGENCY PANEL GROUND BUS.
2000 Market Street
Philadelphia, PA 19103
Fax (215) 568-2639
Tel (215) 568-8250
F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue
H.F. Lenz Company
Mechanical, Electrical, Fire Protection, and Plumbing Engineer
"FULLY SPRINKLERED BUILDING"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Construction and Facilities
Management on e e igh th inc h = on e f oo t
B
A
C
D
E
F thr ee in ch es on e f oo t
6"
6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t
6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Suite 600
SEAL:
P M
05-JAN-2018
ES501
3900 Woodland Ave, Philadelphia, PA 19104
KEY PLAN
N
TME
RENOVATE
SPECIALTY CLINICS
642-16-106
ELECTRICAL DISTRIBUTION RISER
DIAGRAM - DEMOLITION & NEW WORK
RJD
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
1. DASHED LINEWORK INDICATES EXISTING EQUIPMENT, ALL OTHER
WORK SHOWN IS NEW. ALL SYSTEM WIRE SHOWN IS EXISTING.
SCOPE OF WORK INCLUDES, BUT NOT LIMITED TOO, DEMOLITION OF
EXISTING DEVICES, NEW DEVICES/WIRING ADDED INTO EXISTING
SYSTEM AND SYSTEM REPROGRAMMING REQUIRED. SEE
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
2. BEFORE DEMOLITION OF ANY PART OF THE FIRE ALARM SYSTEM IS
TO OCCUR, THE CONTRACTOR SHALL PROVIDE ANY PERMANENT
AND/OR TEMPORARY FIRE ALARM WIRING THAT WILL BE REQUIRED
TO ALLOW FOR THE FIRE ALARM SYSTEM ON THE EIGHTH FLOOR TO
REMAIN 100% OPERATION DURING CONSTRUCTION.
3. COORDINATE ALL SHUT DOWNS WITH VA COR. PROVIDE VA WITH
MINIMUM SEVEN (7), WORKING DAYS, NOTICE PRIOR TO SHUTDOWN.
4. DEMOLISH DEVICES AS INDICATED FROM EXISTING FIRE ALARM
CIRCUITS, EC SHALL MAINTAIN CONTINUITY OF EXISTING CIRCUIT
DURING ALL PHASES OF WORK.
5. NEW DEVICES SHALL CONNECT TO EXISTING FIRE ALARM CIRCUITS.
PROVIDE JUNCTION BOX AND SPLICE AS REQUIRED.
6. DIAGRAM DEPICTS HOW SYSTEM IS TYPICALLY WIRED, REFER TO
FLOOR PLANS FOR QUANTITY AND LOCATION OF DEVICES REQUIRED.
7. SEE DRAWING ES102 FOR DEVICE LOCATIONS REGARDING FIRE
ALARM SYSTEM DEMOLITION.
FIRE ALARM SYSTEM NOTES:
ADDRESSIBLE INPUT MODULE (IAM)
WIRE AND CONDUIT LEGEND
1 #18 (TWISTED/SHIELDED PAIR)-3/4"C
2 #12 (THHN)-3/4"CB
AM
A
2 #14 (THHN)-3/4"CC
4 #14 (THHN)-3/4"CD
END OF LINE RESISTOR (EOL)
VISUAL NOTIFICATION SIGNAL AMPLIFIER PANEL
NAC
FIRE ALARM RISER DIAGRAM
Not To Scale
N
SA
N
DL
N
E
N
S
N
DL
N
CB
N
RCB
EXISTING NURSE CALL
SYTEM HEAD-END
SERVER
N
E
N
DL
N
SA
NOTES:
SUB-BASEMENT DATA
CENTER ROOM B3A138
FIBER OPTIC BACKBONE CABLE
IN OVERALL ARMORED SHEATH
N
RCB
1. ALL WIRING SHALL BE CAT 6 (UNO) INSTALLED IN MIN 3/4"C. CABLING SHALL NOT
BE RUN IN CABLE TRAY SYSTEM.
2. HOMERUNS SHALL NOT EXCEED 320' IN LENGTH.
3. DIAGRAM IS TO ILLUSTRATE HOW DEVICES ARE TYPICALLY WIRED, REFER TO
FLOOR PLANS FOR QUANTITIES AND LOCATIONS. CABLE TYPES CALLED OUT ARE
FOR BIDDING PURPOSES ONLY. EC SHALL
4. PROVIDE MANUFACTURED RECOMMENDED WIRING TO ALL NURSE SYSTEM DEVICE
LOCATIONS.
5. ALL ROOM CONTROL BOARDS SHALL BE PROVIDED ABOVE CEILING IN METALLIC
OUTLET BOX.
6. PROVIDE QUANTITY OF PoE SWITCHES AS REQUIRED TO SUPPLY POWER TO THE
ENTIRE SYSTEM.
7. PROVIDE WALL MOUNTED RACK TO HOUSE NURSE CALL POE SWITCHES WHERE
NEW EQUIPMENT IS INDICATED ON THE FLOOR PLANS.
NEW NURSE CALL
SYTEM POWER OVER
ETHERNET SWITCH(ES)
NURSE CALL SINGLE LINE DIAGRAM
Not To Scale
READER SIGNAL
W
C
RX
DOOR STATUS
REQUEST TO EXIT
REQUEST TO EXIT
24VDC
TCP/IP CONNECTION
PIV-CLASS
AUTHENTICATION
MODULE
(PAM)
TCP/IP CONNECTION
12/20A VAC
EMER.CKT.
12/20A VAC
EMER.CKT.
FIRE ALARM INPUTPS
TYP. BRIDGE RECTIFIER
TYP. INTEGRAL DUAL SPDT
RELAY IN NORMAL STATE
S
P
M
TYPICAL MAGNETIC LOCK ACCESS CONTROLLED DOOR
J
PHYSICAL
ACCESS CONTROL
SYSTEM
(PACS)
PROCESSOR
DATA GATHERING
PNL (DGP)
READER SIGNAL
W
C
RX
DOOR STATUS
REQUEST TO EXIT
REQUEST TO EXIT
24VDC
TCP/IP CONNECTION
PIV-CLASS
AUTHENTICATION
MODULE
(PAM)
TCP/IP CONNECTION
12/20A VAC
EMER.CKT.
12/20A VAC
EMER.CKT.
FIRE ALARM INPUT PS
TYP. BRIDGE RECTIFIER
TYP. INTEGRAL DUAL SPDT
RELAY IN NORMAL STATE
S
P
M
TYPICAL ELECTRONIC STRIKE ACCESS CONTROLLED DOOR
J
PHYSICAL
ACCESS CONTROL
SYSTEM
(PACS)
PROCESSOR
DATA GATHERING
PNL (DGP)
TCP/IP CONNECTION
EXISTING EIGHTH FLOOR PACS NETWORK EQUIPMENT
ENCLOSURE LOCATED IN TELEPHONE ROOM 8A149
TYPICAL CATEGORY 6 CABLE PROVIDED BY CONTRACTOR
EXISTING CATEGORY 6 PATCH PANEL
TYPICAL CATEGORY 6 PATCH CORD
PROVIDED BY CONTRACTOR
EX FIBER TO COPPER SWITCH
TO EX CORE SWITCH
THIS RISER IS DIAGRAMMATIC ONLY AND HAS BEEN PROVIDED TO INDICATE THE GENERAL CONNECTIVITY. THE CONTRACTOR SHALL PROVIDE ALL
REQUIRED EQUIPMENT, DEVICES, OUTLETS, ETC TO PROVIDE A 100% FULLY OPERATIONAL SYSTEM AS DETAILED ON THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS
J
J
RX
RX
N/O
N/C
N/O
N/C
N/C
N/O
N/C
N/O
N/C
NOTE:
PACS SECURE DOOR WIRING DIAGRAM
Not To Scale
EXISTING FIRE ALARM
TERMINAL CABINET
NAC
AM AM
F
S
F
S
F
S
FF
F
DH
F
DH
FAV FAV FV FA FAV FAV
ELECTRICAL ROOM 8A105
B
C
C
A
2000 Market Street
Philadelphia, PA 19103
Fax (215) 568-2639
Tel (215) 568-8250
F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue
H.F. Lenz Company
Mechanical, Electrical, Fire Protection, and Plumbing Engineer
"FULLY SPRINKLERED BUILDING"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Construction and Facilities
Management on e e igh th inc h = on e f oo t
B
A
C
D
E
F thr ee in ch es on e f oo t
6"
6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t
6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Suite 600
SEAL:
P M
05-JAN-2018
ES502
3900 Woodland Ave, Philadelphia, PA 19104
KEY PLAN
N
TME
RENOVATE
SPECIALTY CLINICS
642-16-106
ELECTRICAL DIAGRAMS
LOW VOLTAGE SYSTEMS
RJD
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
2000 Market Street
Philadelphia, PA 19103
Fax (215) 568-2639
Tel (215) 568-8250
F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue
H.F. Lenz Company
Mechanical, Electrical, Fire Protection, and Plumbing Engineer
"FULLY SPRINKLERED BUILDING"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Construction and Facilities
Management on e e igh th inc h = on e f oo t
B
A
C
D
E
F thr ee in ch es on e f oo t
6"
6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t
6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Suite 600
SEAL:
P M
05-JAN-2018
ES601
3900 Woodland Ave, Philadelphia, PA 19104
KEY PLAN
N
TME
RENOVATE
SPECIALTY CLINICS
642-16-106
PANELBOARD SCHEDULES
RJD
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
2000 Market Street
Philadelphia, PA 19103
Fax (215) 568-2639
Tel (215) 568-8250
F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue
H.F. Lenz Company
Mechanical, Electrical, Fire Protection, and Plumbing Engineer
"FULLY SPRINKLERED BUILDING"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Office of
Construction and Facilities
Management on e e igh th inc h = on e f oo t
B
A
C
D
E
F thr ee in ch es on e f oo t
6"
6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t
6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Suite 600
SEAL:
P M
05-JAN-2018
ES602
3900 Woodland Ave, Philadelphia, PA 19104
KEY PLAN
N
TME
RENOVATE
SPECIALTY CLINICS
642-16-106
LIGHTING FIXTURE SCHEDULE
RJD
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text
| ES401 |
| Sheets and Views |
| ES401 |
| ES402 |
| Sheets and Views |
| ES402 |
| ES501 |
| Sheets and Views |
| ES501 |
| ES502 |
| Sheets and Views |
| ES502 |
| ES601 |
| Sheets and Views |
| ES601 |
| ES602 |
| Sheets and Views |
| ES602 |
File details come from the government source that posted it.