Renovate Specialty Clinics #642-16-106
Solicitation number
36C24418B0288
Issued by

About this file

36C24418B0288 Drawings 29-34.pdf

View the file

Other files

File Type Posted
36C24418C0183-000.docx DOCX document
36C24418B0288-00002000.docx DOCX document
36C24418B0288-00002001.pdf PDF
36C24418B0288-00001000.docx DOCX document
36C24418B0288-00001001.pdf PDF
36C24418B0288-001.docx DOCX document
36C24418B0288-006.pdf PDF
36C24418B0288-002.pdf PDF
36C24418B0288-003.pdf PDF
36C24418B0288-004.pdf PDF
36C24418B0288-007.pdf PDF
36C24418B0288-000.docx DOCX document
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LUMINAIRE SUSPENSION

WIRES (#10 MIN)

ATTACHED TO

STRUCTURE

(TYP EA. CORNER)

3 TWIST MINIMUM

(TYP)

FIXTURE WHIP FROM

JUNCTION BOX

(6FT. LONG MAX.)

LUMINAIRE.

REFER TO

SCHEDULE

LUMINAIRE MANUFACTURER'S

EARTHQUAKE CLIP, (4) PER FIXTURE

AT CORNERS. ATTACH WITH SHEET

METAL SCREW

ACOUSTICAL CEILING

TILE (TYP)

ARCHITECTURAL

CEILING GRID

LUMINAIRE.

REFER TO

SCHEDULE

CEILING HANGER

WIRE, TYP.

RECESSED CAN

LUMINAIRE

ARCHITECTURAL

CEILING GRID

WIRE TIE OR SCREW

BAR HANGER TO

ARCHITECTURAL

CEILING GRID TYP.

LUMINAIRE

BAR HANGERS

12GA. HANGER WIRE AT DIAGONAL

CORNER ATTACHED TO STRUCTURE

ACOUSTICAL

CEILING TILE (TYP)

RECESSED CAN

LUMINAIRE

ARCHITECUTRAL

CEILING GRID

CEILING HANGER WIRE

ARCHITECTURAL

CEILING GRID

ARCHITECTURAL

CEILING GRID

ACOUSTICAL

CEILING

TILE (TYP)

#12 GA. HANGER WIRE THROUGH INTEGRAL

GALVANIZED LIPPED STEEL MOUNTING

CHANNEL & ATTACHED TO STRUCTURE

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

JUNCTION BOX

LOCKING SQUARE

WASHER & NUT

1/4" SCREW

ARCHITECTURAL

CEILING GRID

WIRE TIE THROUGH

MOUNTING CHANNEL &

CROSS BEAM, TYP.

CONDUIT, TYP MINERAL WOOL

(FIRMLY PACKED)

FIRESTOP SEALANT

PER SECTION 07 84 00,

FIRESTOPPING

3/8" MAX

JUNCTION BOX

(SIZE AS REQUIRED)

CONDUIT COMPRESSION

FITTING, TYP.

SPRING

NUT, TYP

INTEGRAL GALVANIZED

LIPPED STEAL MOUNTING

CHANNEL, TYP.

FLOOR SLAB,

TYP.

STEEL EXPANSION

ANCHOR, TYP

NOTES:

FOR VOICE JACKS, PROVIDE ONE (1) 4 PAIR, 24

AWG, UNSHIELDED TWISTED PAIR, CATEGORY

5e CABLE. SPLIT THE 4 PAIRS BETWEEN THE

TWO VOICE JACKS; WHITE/BLUE AND WHITE/

ORANGE PAIRS TERMINATE TO THE TOP JACK,

WHITE/GREEN AND WHITE/BROWN PAIRS

TERMINATE TO THE BOTTOM JACK. CABLING

SHALL BE PROVIDED WITH WHITE OUTER

JACKET

1.

NOTES:

OUTLETS

TELEPHONE

DATA AND

MTD 18" AFF BY EC.

RING RECESSED IN WALL,

4"x 4"x 2 1/2" BACKBOX

W/ SINGLE GANG PLASTER

FLOOR

FINISH CEILING

DATA/PHONE CABLING, BY EC. PROVIDE CABLE

FROM USER JACKS TO TELECOM CLOSET 5B118

VIA NEW WIREWAY. ONCE IN TELECOM ROOM,

PROVIDE 20' OF SLACK CABLING, COILED FOR

ORGANIZING PURPOSES, TO ALLOW EXTENSION

AND TERMINATION OF CABLING, TERMINATIONS

DONE UNDER OTHER CONTRACTS.

REMOVABLE

TYPE CEILING

PROVIDE 1" CONDUIT

TO NEW WIREWAY

SINGLE GANG PLASTER RING BY EC

CATEGORY 5e COMPLIMENT, EIGHT POSITION, RJ-45

NON-KEYED COMMUNICATIONS

OUTLETS (TYPICAL OF FOUR)

OUTLET

NAMEPLATE

LABEL (TYP)

SINGLE GANG PLASTIC

FACEPLATE

JACKS DESIGNATED

FOR VOICE SHALL BE

WHITE IN COLOR WITH

VOICE ICON

UNLESS NOTED OTHERWISE ON THE DRAWINGS, THIS DETAIL APPLIES TO THE SYMBOL

SHOWN ON THE FLOOR PLANS.

DETAIL IS FOR DIAGRAMMATICAL AND

BIDDING PURPOSES ONLY. FIXTURE(S)

SHALL BE INSTALLED AS PER

MANUFACTURERS RECOMMENDATIONS

NOTE:

DETAIL IS FOR DIAGRAMMATICAL AND

BIDDING PURPOSES ONLY. FIXTURE(S)

SHALL BE INSTALLED AS PER

MANUFACTURERS RECOMMENDATIONS

NOTE:

DETAIL IS FOR DIAGRAMMATICAL AND

BIDDING PURPOSES ONLY. FIXTURE(S)

SHALL BE INSTALLED AS PER

MANUFACTURERS RECOMMENDATIONS

NOTE:

1" CONCEALED

CONDUIT BY EC

4"x4"x2-1/2"D OUTLET

BOX BY EC

THREE (3) CATEGORY 5e

CABLING BY EC

TO EACH DATA JACK PROVIDE 4 PAIR,

24 AWG, UNSHIELDED TWISTED PAIR,

CATEGORY 5e CABLES FOR DATA

OUTLETS. CABLING SHALL BE

PROVIDED WITH BLUE OUTER JACKET

8 POSITION, 8 CONDUCTOR,

NON-KEYED RJ-45 CATEGORY

5e JACK BY EC

(TYPICAL OF FOUR SHOWN)

1" CONDUIT BY EC, PROVIDE NEW

CABLING IN RACEWAY FOR ENTIRE

RUN TO TELECOM CLOSET

1. THIS DETAIL APPLIES TO THE SYMBOL SHOWN ON

THE FLOOR PLANS.

2. ALL DATA WIRING SHALL BE INSTALLED IN ACCORDANCE

WITH APPLICABLE CODES AND STANDARDS.

3. ALL DATA WIRING SHALL BE INSTALLED BY A CERTIFIED

INSTALLER.

4. THIS DETAIL IS INTENDED TO ILLUSTRATE THE INTENT OF

THE DATA HORIZONTAL WIRING AND DATA OUTLET

CONFIGURATION ONLY, ACTUAL REQUIREMENTS AND

CONDITIONS MAY VARY. IT SHALL BE THE

RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO

VERIFY SITE CONDITIONS & COORDINATE INSTALLATION

REQUIREMENTS WITH OWNER & ARCHITECT.

5. COORDINATE EXACT INFORMATION OUTLET LOCATION

WITH PLANNED FURNITURE LAYOUT.

6. AT FACEPLATE VOICE JACKS, SPLIT CATEGORY 5e CABLE

SHALL TERMINATE AS FOLLOWS. ON TOP JACK,

WHITE/BLUE PAIR SHALL TERMINATE AT WHITE/BLUE PINS

AND WHITE/ORANGE SHALL TERMINATE AT WHITE/GREEN

PINS. AT BOTTOM JACK, WHITE/GREEN PAIR SHALL

TERMINATE AT WHITE/BLUE PINS AND WHITE/BROWN

PAIR SHALL TERMINATE AT WHITE/GREEN PINS.

7. DATA AND VOICE CABLING SHALL BE TERMINATED AT

DATA JACKS FOLLOWING PIN PAIR ASSIGNMENTS OF

EIA/TIA STANDARD T568A AND 606.

JACKS DESIGNATED

FOR DATA SHALL BE

ORANGE IN COLOR

WITH DATA ICON

FLOOR SLAB PENETRATION DETAIL

NOT TO SCALE

LUMINAIRE MOUNTING - LAY-IN CEILING

NOT TO SCALE

DOWNLIGHT MOUNTING - LAY-IN CEILING

NOT TO SCALE

COMBINATION DATA/TELEPHONE OUTLET AND FACEPLATE DETAIL

NOT TO SCALE

EXIT SIGN MOUNTING - LAY-IN CEILING

NOT TO SCALE

COMBINATION DATA/TELEPHONE OUTLET ELEVATION

NOT TO SCALE

NOTES:

SINGLE GANG PLASTER RING BY EC

JACKS SHALL BE ORANGE IN

COLOR WITH DATA ICON;

CATEGORY 5e COMPLIMENT, EIGHT POSITION, RJ-45

NON-KEYED COMMUNICATIONS

OUTLETS

OUTLET

NAMEPLATE

LABEL (TYP)

SINGLE GANG PLASTIC

FACEPLATE

4"x4"x2-1/2"D OUTLET

BOX BY EC

ONE (1) CATEGORY 5e

CABLING BY EC

TO EACH DATA JACK/VOICE JACK PROVIDE 4

PAIR, 24 AWG, UNSHIELDED TWISTED PAIR,

CATEGORY 5e CABLES FOR DATA/VOICE

OUTLETS. CABLING SHALL BE PROVIDED WITH

BLUE OUTER JACKET

8 POSITION, 8 CONDUCTOR,

NON-KEYED RJ-45 CATEGORY

5e JACK BY EC

1" CONDUIT TO ABOVE

CEILING WIREWAY BY EC

1. THIS DETAIL APPLIES TO THE SYMBOLS , ,

SHOWN ON THE FLOOR PLANS.

2. ALL DATA WIRING SHALL BE INSTALLED IN ACCORDANCE

WITH APPLICABLE CODES AND STANDARDS.

3. ALL DATA WIRING SHALL BE INSTALLED BY A CERTIFIED

INSTALLER.

4. THIS DETAIL IS INTENDED TO ILLUSTRATE THE INTENT OF

THE DATA HORIZONTAL WIRING AND DATA OUTLET

CONFIGURATION ONLY, ACTUAL REQUIREMENTS AND

CONDITIONS MAY VARY. IT SHALL BE THE

RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO

VERIFY SITE CONDITIONS & COORDINATE INSTALLATION

REQUIREMENTS WITH OWNER & ARCHITECT.

5. COORDINATE EXACT INFORMATION OUTLET LOCATION

WITH PLANNED FURNITURE LAYOUT.

6. DATA AND VOICE CABLING SHALL BE TERMINATED AT

DATA JACKS FOLLOWING PIN PAIR ASSIGNMENTS OF

EIA/TIA STANDARD T568A AND 606.

SINGLE OUTLET COMMUNICATIONS DETAIL

NOT TO SCALE

WAP W

1.

NOTES:

WITH CEILING BY EC.

RING MOUNTED FLUSH

4"x 4"x 2 1/2" BACKBOX

W/ SINGLE GANG PLASTER

FLOOR

FINISH CEILING

DATA/PHONE CABLING, BY EC. PROVIDE CABLE

FROM USER JACKS TO TELECOM CLOSET 5B118

VIA NEW WIREWAY. ONCE IN TELECOM ROOM,

PROVIDE 20' OF SLACK CABLING, COILED FOR

ORGANIZING PURPOSES, TO ALLOW EXTENSION

AND TERMINATION OF CABLING, TERMINATIONS

DONE UNDER OTHER CONTRACTS.

REMOVABLE

TYPE CEILING

UNLESS NOTED OTHERWISE ON THE DRAWINGS, THIS DETAIL APPLIES TO THE SYMBOL

SHOWN ON THE FLOOR PLANS.

WIRELESS ACCESS POINT DATA OUTLET ELEVATION

NOT TO SCALE

WAP

1"C. BY EC

PROVIDE 1" CONDUIT

TO NEW WIREWAY

TOP

FRONT SIDE

ISOMETRIC

NOTE:

TRAY DESIGNED PER NEMA VE-1 CSA C22.2 No. 126

WIRE BASKET CABLE TRAY DETAIL

NOT TO SCALE

TV

THIS DETAIL APPLIES TO THE SYMBOL SHOWN

ON THE FLOOR PLANS.

NOTES:

1.

REMOVABLE TYPE

CEILING

FLOOR

FINISH CEILING

POWER DUPLEX

RECEPTACLE

V

T

COAX TV CABLING BY

CABLE INSTALLER

ROUTE 1"C TO AND TERMINATE AT

CLOSET HOUSING CABLE TV TAP PANEL,

SEE DRAWING FOR LOCATION OF CLOSET

2.

EC SHALL PROVIDE ALL OUTLET BOXES,

RACEWAYS, TELEVISION CABLING, AMPS, TAP

PANELS AS NECESSARY.

WITH PULLCORD BY EC

1" CONCEALED CONDUIT

4"x 4"x 2 1/2" BACKBOX BY

EC W/ SINGLE GANG

PLASTER RING RECESSED

IN WALL, MTD 12" BELOW

CEILING OR 18" AFF,

COORDINATE W/

ARCHITECT

TELEVISION WALL OUTLET ELEVATION

NOT TO SCALE

NEW WIREWAY

NEW WIREWAY NEW WIREWAY

2000 Market Street

Philadelphia, PA 19103

Fax (215) 568-2639

Tel (215) 568-8250

F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue

H.F. Lenz Company

Mechanical, Electrical, Fire Protection, and Plumbing Engineer

"FULLY SPRINKLERED BUILDING"

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of

Construction and Facilities

Management on e e igh th inc h = on e f oo t

B

A

C

D

E

F thr ee in ch es on e f oo t

6"

6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t

6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Suite 600

SEAL:

P M

05-JAN-2018

ES401

3900 Woodland Ave, Philadelphia, PA 19104

KEY PLAN

N

TME

RENOVATE

SPECIALTY CLINICS

642-16-106

ELECTRICAL DETAILS

RJD

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

AutoCAD SHX Text

NOTES:

1. SEQUENCE OF OPERATION: IN THIS CONFIGURATION, THE

SINGLE RELAY CONTROLLER DEFAULTS TO MANUAL -

ON/AUTOMATIC OFF. MAXIMUM OF 4 ROOM CONTROLLERS,

CONTROLLING UP TO 8 LOADS.

UNSWITCHED

HOT BLK

120/277

NEUTRAL WHT

WHITE

RED

ISOLATED RELAY INTERFACE

OCCUPANCY SENSOR

COUPLER (IF REQUIRED)

RJ45 (TYPICAL)

LOW VOLTAGE SWITCH

LOW VOLTAGE SWITCH

(AS NEEDED)

SIGNAL FOR ROOM

HVAC CONTROL

CAT 5e

CABLES

(TYPICAL)

CAT 5e

CABLES

(TYPICAL)

CAT 5e

CABLES

(TYPICAL)

SINGLE RELAY ON/OFF

ROOM CONTROLLER

LIGHTING LOAD

NOTES:

1. SEQUENCE OF OPERATION: IN THIS CONFIGURATION, THE

DUAL-RELAY CONTROLLER DEFAULTS TO MULTI-LEVEL

AUTOMATICALLY-ON/AUTOMATIC OFF. LOAD (a) TURNS

AUTOMATICALLY ON AUTOMATICALLY AND LOAD (b)

DEFAULTS TO MANUAL-ON CONTROL; BOTH LOADS TURN

AUTOMATICALLY OFF. MAXIMUM OF 4 ROOM CONTROLLERS,

CONTROLLING UP TO 8 LOADS.

UNSWITCHED

HOT BLK

120/277

NEUTRAL WHT

WHITE

RED

ISOLATED RELAY INTERFACE

OCCUPANCY SENSOR

COUPLER (IF REQUIRED)

RJ45 (TYPICAL)

LOW VOLTAGE SWITCH

LOW VOLTAGE SWITCH

(AS NEEDED)

SIGNAL FOR ROOM HVAC CONTROL

CAT 6

CABLES

(TYPICAL)

CAT 6

CABLES

(TYPICAL)

CAT 6

CABLES

(TYPICAL)

DUAL RELAY ON/OFF

ROOM CONTROLLER

LIGHTING LOAD (a)

YELLOW

LIGHTING LOAD (a)

NOTES:

1. SEQUENCE OF OPERATION: IN THIS CONFIGURATION, THE

DUAL-RELAY CONTROLLER DEFAULTS TO MULTI-LEVEL

AUTOMATIC-ON/AUTOMATIC OFF WITH DIMMING OF ALL LOADS.

LOAD (a) TURNS ON AUTOMATICALLY AND LOAD (b) DEFAULTS TO

MANUAL-ON CONTROL; BOTH LOADS TURN AUTOMATICALLY OFF.

MAXIMUM OF 4 ROOM CONTROLLERS, CONTROLLING UP TO 8

LOADS. DEFAULT DIMMING PARAMETERS ARE ESTABLISHED

INCLUDING: LEVELS FOR PRESETS 1-4; FADE TIMES; AND FADE

AND RAMP RATES. DIMMING AND SYSTEM PARAMETERS MAY

BE CUSTOMIZED.

SIGNAL FOR

ROOM HVAC

CONTROL

CLASS 2 0-10 VOLT

CONTROL WIRING

ISOLATED RELAY INTERFACE

RED

YEL

VIO

GRY

VIO

GRY

DUAL RELAY

ON/OFF/0-110V DIMMING

ROOM CONTROLLER

NEUTRAL WHT

UNSWITCHED

HOT BLK

120/277

DIGITAL

5-BUTTON SCENE

SWITCH

OCCUPANCY SENSOR AND/OR

DAYLIGHTING SENSOR

COUPLER (IF REQUIRED)

CAT 6 CABLE

CAT 6 CABLE

CAT 6 CABLE

V I O

G R

Y

V I O

G R

Y

LIGHTING

LOAD (a)

LIGHTING

LOAD (b)

BLUE LOAD

STATUS LED(S)

ON

TWO (2) RJ45

CONNECTORS

OFF

RED CONFIGURATION

LED

SINGLE BUTTON DIGITAL

SWITCH

1. THIS DETAIL APPLIES WHERE OR IS SHOWN ON THE PLANS.

2. PROVIDE MANUFACTURER RECOMMENDATION LABELING ON

SWITCHES TO DENOTE THE FUNCTION OF THE SWITCH.

NOTES:

L1

BLUE LOAD

STATUS LED(S)

ON/RAISE

TWO (2) RJ45

CONNECTORS

OFF/LOWER

RED CONFIGURATION

LED

SINGLE BUTTON DIGITAL

DIMMER SWITCH

1. THIS DETAIL APPLIES WHERE OR IS SHOWN ON THE PLANS.

2. PROVIDE MANUFACTURER RECOMMENDATION LABELING ON

SWITCHES TO DENOTE THE FUNCTION OF THE SWITCH.

NOTES:

LED DIMMING LEVEL

INDICATOR

L1

D

BLUE LOAD

STATUS LED(S)

ON/OFF/LOAD A ON-OFF

TWO (2) RJ45

CONNECTORS

ON/OFF/LOAD B ON-OFF

RED CONFIGURATION

LED

TWO BUTTON DIGITAL

SWITCH

1. THIS DETAIL APPLIES WHERE OR IS SHOWN ON THE PLANS.

2. PROVIDE MANUFACTURER RECOMMENDATION LABELING ON SWITCHES

TO DENOTE THE FUNCTION OF THE SWITCH.

NOTES:

L2 ab

L2

SINGLE RELAY ROOM LIGHTING CONTROL DIAGRAM

NOT TO SCALE

DOUBLE RELAY ROOM LIGHTING CONTROL DIAGRAM

NOT TO SCALE

DIMMING RELAY ROOM LIGHTING CONTROL DIAGRAM

NOT TO SCALE

SINGLE BUTTON WALL SWITCH

NOT TO SCALE

SINGLE BUTTON WALL SWITCH W/ DIMMING

NOT TO SCALE

TWO BUTTON WALL SWITCH

NOT TO SCALE

WALL SWITCH SENSOR

GREEN

BLACK

LOAD

BLACK

H

N

W/ DUAL TECHNOLOGY

WALL SWITCH SENSOR

GREEN

BLACK

LOAD

BLACK

H

N

W/ DUAL TECHNOLOGY

LINE VOLTAGE WALL SWITCH SENSOR

NOT TO SCALE

AND ON/OFF SWITCH

LINE VOLTAGE DIMMER WALL SWITCH SENSOR

NOT TO SCALE

ON/OFF ROCKER SWITCH

AND 0-10V SLIDE DIMMER

JUNCTION

BOX,

SIZE AS

NEEDED

IAM

J

FINISHED CEILING

3/4"CONDUIT WITH

NYLON PULLCORD

2 #14 - 3/4"CONDUIT

PROVIDE RECESSED 4"x4"

OUTLET BOX MOUNTED ON

ENTRANCE SIDE OF DOOR

FOR SECURITY CARD READER.

CONDUIT FOR ELECTRIC STRIKE.

PROVIDE CONDUIT TO DOOR FRAME,

CAP WITH INSULATED BUSHING.

CONDUIT FOR DOOR CONTACT.

PROVIDE CONDUIT TO DOOR

FRAME, CAP WITH INSULATED

BUSHING

REQUEST TO EXIT MOUNTED ON

EGRESS SIDE OF DOOR. PROVIDE

CONDUIT TO DOOR FRAME, CAP

WITH INSULATED BUSHING

TO FIRE ALARM CONTROL PANEL. DOOR SHALL

UNLOCK UPON ACTIVATION OF FIRE ALARM

SYSTEM ON FLOOR.

FINISHED FLOOR

1. THIS DETAIL APPLIES TO SECURE, SINGLE DOOR

LOCATIONS FLOOR PLANS.

2. COORDINATE FINAL LOCATION OF BOXES WITH

ARCHITECT BEFORE PERFORMING ROUGH-INS.

3. DETAIL SHOWS TYPICAL ARRANGEMENT OF

RACEWAYS AND BOXES REQUIRED FOR EC

PROVIDED DOOR ACCESS EQUIPMENT, REFER TO THE

DRAWINGS FOR ANY SPECIFIC LOCATIONS OF DEVICES.

4. EC SHALL PROVIDE COMPLETE DOOR ACCESS

SYSTEM. SEE PHASE 1 PACS DRAWING FOR MROE

INFORMATION.

NOTES:

J

PROVIDE RECESSED 4"x4" OUTLET

BOX MOUNTED ON EGRESS SIDE

OF DOOR FOR REQUEST TO EXIT

DEVICE.

SINGLE SECURE DOOR ELEVATION DETAIL

NOT TO SCALE

2000 Market Street

Philadelphia, PA 19103

Fax (215) 568-2639

Tel (215) 568-8250

F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue

H.F. Lenz Company

Mechanical, Electrical, Fire Protection, and Plumbing Engineer

"FULLY SPRINKLERED BUILDING"

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of

Construction and Facilities

Management on e e igh th inc h = on e f oo t

B

A

C

D

E

F thr ee in ch es on e f oo t

6"

6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t

6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Suite 600

SEAL:

P M

05-JAN-2018

ES402

3900 Woodland Ave, Philadelphia, PA 19104

KEY PLAN

N

TME

RENOVATE

SPECIALTY CLINICS

642-16-106

ELECTRICAL DETAILS

RJD

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

1ST FLOOR

PIPE BASEMENT

EXISTING SUBSTATION No.3

480/277V

EXISTING

EMERGENCY

LIFE

SAFETY

PANEL

'DEL2'

480/277V

225A MCB

BASEMENT

2ND FLOOR

3RD FLOOR

4TH FLOOR

5TH FLOOR

6TH FLOOR

7TH FLOOR

8TH FLOOR

9TH FLOOR

10'

12'

12'

12'

12'

12'

12'

12'

EXISTING

EMERGENCY

CRITICAL

PANEL

'DEC2'

208/120V

800A MCB

12'

EXISTING

EMERGENCY

CRITICAL

PANEL

'EC5A'

208/120V

EXISTING

EMERGENCY

LIFE

SAFETY

PANEL

'EL7B'

480/277V

EXISTING

EMERGENCY

LIFE

SAFETY

PANEL

'EL8B'

480/277V

EXISTING

EMERGENCY

CRITICAL

PANEL

'EC8A'

208/120V

EXISTING

EMERGENCY

CRITICAL

PANEL

'DEC3'

480/277V

800A MCB

EXISTING

EMERGENCY

CRITICAL

PANEL

'EC7H'

480/277V

EXISTING

EMERGENCY

CRITICAL

PANEL

'EC8H'

480/277V

EXISTING

NORMAL

POWER

PANEL

'7SHA'

480/277V

EX. 112.5kVA

TRANSFORMER

PRI - 480V

SEC - 208/120V

EXISTING

NORMAL

POWER

PANEL

'7SL'

208/120V

EXISTING

NORMAL

POWER

PANEL

'7SLA'

208/120V

EX. 75kVA

TRANSFORMER

PRI - 480V

SEC - 208/120V

EXISTING

NORMAL

POWER

PANEL

'7NL'

208/120V

EXISTING

NORMAL

POWER

PANEL

'7NLA'

208/120V

EXISTING

NORMAL

POWER

PANEL

'8SHA'

480/277V

EXISTING

NORMAL

POWER

PANEL

'8SLA'

208/120V

EXISTING

NORMAL

POWER

PANEL

'8NLA'

208/120V

EXISTING

NORMAL

POWER

PANEL

'5SHA'

480/277V

EXISTING

NORMAL

POWER

PANEL

'5SLA'

208/120V

EXISTING

NORMAL

POWER

PANEL

'5NLA'

208/120V

EXISTING

NORMAL

POWER

PANEL

'7EHA'

480/277V

EX. 75kVA

TRANSFORMER

PRI - 480V

SEC - 208/120V

EXISTING

NORMAL

POWER

PANEL

'7EL'

208/120V

EXISTING

NORMAL

POWER

PANEL

'7ELA'

208/120V

EX. 45kVA

TRANSFORMER

PRI - 480V

SEC - 208/120V

EXISTING

NORMAL

POWER

PANEL

'7ELB'

208/120V

EXISTING

NORMAL

POWER

PANEL

'8EHA'

480/277V

EXISTING

NORMAL

POWER

PANEL

'8ELA'

208/120V

EXISTING

NORMAL

POWER

PANEL

'8ELB'

208/120V

EXISTING

NORMAL

POWER

PANEL

'5EHA'

480/277V

EXISTING

NORMAL

POWER

PANEL

'5ELA'

208/120V

EXISTING

NORMAL

POWER

PANEL

'5ELB'

208/120V

NEW

NORMAL

POWER

PANEL

'8ELB'

100A MCB

225A BUS

208/120V

KEYNOTES ELSEWHERE THIS DRAWING:

NEW PANEL(S) SHALL BE PROVIDED IN SAME LOCATION AS DEMOLISHED PANEL. RECONNECT

EXISTING FEEDERS TO PANEL AND EXISTING BRANCH CIRCUITS TO BREAKERS PROVIDED IN PANEL.

NEW

NORMAL

POWER

PANEL

'8ELA'

100A MCB

225A BUS

208/120V

EXISTING SUBSTATION No.1

480/277V

DISCONNECT EXISTING FEEDER FROM EXISTING PANEL. DEMOLISH EXISTING PANEL AS SHOWN, PROVIDE JUNCTION BOXES FOR EXISTING BRANCH CIRCUITS THAT ARE TO REMAIN, CIRCUITS SHALL

BE RE-CONNECTED TO NEW PANEL. FEEDER SHALL REMAIN FOR RE-CONNECTION TO NEW PANEL.

EXISTING SUBSTATION No.4

480/277V

EXISTING

NORMAL

POWER

PANEL

'PNDP'

480/277V

EXISTING

NORMAL

POWER

PANEL

'PN'

480/277V

EXISTING

NORMAL

POWER

PANEL

'PN1'

480/277V

EXISTING

NORMAL

POWER

PANEL

'PN2'

480/277V

EXISTING

NORMAL

POWER

PANEL

'PN3'

480/277V

EX. 45kVA

TRANSFORMER

PRI - 480V

SEC - 208/120V

EXISTING

NORMAL

POWER

PANEL

'PNA'

208/120V

EXISTING

NORMAL

POWER

PANEL

'PNA1'

208/120V

EXISTING

EMERGENCY

LIFE

SAFETY

PANEL

'EL8B1'

208/120V

EX. 37.5kVA

TRANSFORMER

PRI - 480V

SEC - 208/120V

GENERAL ELECTRICAL NOTES THIS DRAWING:

1. REPLACEMENT OF PANELS SHALL OCCUR OVER WEEKENDS OR OFF-HOUR SHIFTS TO MINIMIZE

DOWN TIME FOR SECTIONS OF FLOOR UN-AFFECTED BY CURRENT PHASE OF CONSTRUCTION.

2. FOR PANELS SHOWN AS DEMOLISHED, REFER TO PANEL SCHEDULES ON DRAWINGS E-601 &

E-602 FOR EXISTING BRANCH CIRCUITS THAT ARE TO REMAIN AND BE RE-CONNECTED TO NEW

PANEL(S)

1 #10 GRD. IN 3/4"C. FROM NORMAL POWER

PANEL GROUND BUS TO

NORMAL/EMERGENCY PANEL GROUND BUS.

2000 Market Street

Philadelphia, PA 19103

Fax (215) 568-2639

Tel (215) 568-8250

F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue

H.F. Lenz Company

Mechanical, Electrical, Fire Protection, and Plumbing Engineer

"FULLY SPRINKLERED BUILDING"

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of

Construction and Facilities

Management on e e igh th inc h = on e f oo t

B

A

C

D

E

F thr ee in ch es on e f oo t

6"

6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t

6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Suite 600

SEAL:

P M

05-JAN-2018

ES501

3900 Woodland Ave, Philadelphia, PA 19104

KEY PLAN

N

TME

RENOVATE

SPECIALTY CLINICS

642-16-106

ELECTRICAL DISTRIBUTION RISER

DIAGRAM - DEMOLITION & NEW WORK

RJD

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

1. DASHED LINEWORK INDICATES EXISTING EQUIPMENT, ALL OTHER

WORK SHOWN IS NEW. ALL SYSTEM WIRE SHOWN IS EXISTING.

SCOPE OF WORK INCLUDES, BUT NOT LIMITED TOO, DEMOLITION OF

EXISTING DEVICES, NEW DEVICES/WIRING ADDED INTO EXISTING

SYSTEM AND SYSTEM REPROGRAMMING REQUIRED. SEE

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

2. BEFORE DEMOLITION OF ANY PART OF THE FIRE ALARM SYSTEM IS

TO OCCUR, THE CONTRACTOR SHALL PROVIDE ANY PERMANENT

AND/OR TEMPORARY FIRE ALARM WIRING THAT WILL BE REQUIRED

TO ALLOW FOR THE FIRE ALARM SYSTEM ON THE EIGHTH FLOOR TO

REMAIN 100% OPERATION DURING CONSTRUCTION.

3. COORDINATE ALL SHUT DOWNS WITH VA COR. PROVIDE VA WITH

MINIMUM SEVEN (7), WORKING DAYS, NOTICE PRIOR TO SHUTDOWN.

4. DEMOLISH DEVICES AS INDICATED FROM EXISTING FIRE ALARM

CIRCUITS, EC SHALL MAINTAIN CONTINUITY OF EXISTING CIRCUIT

DURING ALL PHASES OF WORK.

5. NEW DEVICES SHALL CONNECT TO EXISTING FIRE ALARM CIRCUITS.

PROVIDE JUNCTION BOX AND SPLICE AS REQUIRED.

6. DIAGRAM DEPICTS HOW SYSTEM IS TYPICALLY WIRED, REFER TO

FLOOR PLANS FOR QUANTITY AND LOCATION OF DEVICES REQUIRED.

7. SEE DRAWING ES102 FOR DEVICE LOCATIONS REGARDING FIRE

ALARM SYSTEM DEMOLITION.

FIRE ALARM SYSTEM NOTES:

ADDRESSIBLE INPUT MODULE (IAM)

WIRE AND CONDUIT LEGEND

1 #18 (TWISTED/SHIELDED PAIR)-3/4"C

2 #12 (THHN)-3/4"CB

AM

A

2 #14 (THHN)-3/4"CC

4 #14 (THHN)-3/4"CD

END OF LINE RESISTOR (EOL)

VISUAL NOTIFICATION SIGNAL AMPLIFIER PANEL

NAC

FIRE ALARM RISER DIAGRAM

Not To Scale

N

SA

N

DL

N

E

N

S

N

DL

N

CB

N

RCB

EXISTING NURSE CALL

SYTEM HEAD-END

SERVER

N

E

N

DL

N

SA

NOTES:

SUB-BASEMENT DATA

CENTER ROOM B3A138

FIBER OPTIC BACKBONE CABLE

IN OVERALL ARMORED SHEATH

N

RCB

1. ALL WIRING SHALL BE CAT 6 (UNO) INSTALLED IN MIN 3/4"C. CABLING SHALL NOT

BE RUN IN CABLE TRAY SYSTEM.

2. HOMERUNS SHALL NOT EXCEED 320' IN LENGTH.

3. DIAGRAM IS TO ILLUSTRATE HOW DEVICES ARE TYPICALLY WIRED, REFER TO

FLOOR PLANS FOR QUANTITIES AND LOCATIONS. CABLE TYPES CALLED OUT ARE

FOR BIDDING PURPOSES ONLY. EC SHALL

4. PROVIDE MANUFACTURED RECOMMENDED WIRING TO ALL NURSE SYSTEM DEVICE

LOCATIONS.

5. ALL ROOM CONTROL BOARDS SHALL BE PROVIDED ABOVE CEILING IN METALLIC

OUTLET BOX.

6. PROVIDE QUANTITY OF PoE SWITCHES AS REQUIRED TO SUPPLY POWER TO THE

ENTIRE SYSTEM.

7. PROVIDE WALL MOUNTED RACK TO HOUSE NURSE CALL POE SWITCHES WHERE

NEW EQUIPMENT IS INDICATED ON THE FLOOR PLANS.

NEW NURSE CALL

SYTEM POWER OVER

ETHERNET SWITCH(ES)

NURSE CALL SINGLE LINE DIAGRAM

Not To Scale

READER SIGNAL

W

C

RX

DOOR STATUS

REQUEST TO EXIT

REQUEST TO EXIT

24VDC

TCP/IP CONNECTION

PIV-CLASS

AUTHENTICATION

MODULE

(PAM)

TCP/IP CONNECTION

12/20A VAC

EMER.CKT.

12/20A VAC

EMER.CKT.

FIRE ALARM INPUTPS

TYP. BRIDGE RECTIFIER

TYP. INTEGRAL DUAL SPDT

RELAY IN NORMAL STATE

S

P

M

TYPICAL MAGNETIC LOCK ACCESS CONTROLLED DOOR

J

PHYSICAL

ACCESS CONTROL

SYSTEM

(PACS)

PROCESSOR

DATA GATHERING

PNL (DGP)

READER SIGNAL

W

C

RX

DOOR STATUS

REQUEST TO EXIT

REQUEST TO EXIT

24VDC

TCP/IP CONNECTION

PIV-CLASS

AUTHENTICATION

MODULE

(PAM)

TCP/IP CONNECTION

12/20A VAC

EMER.CKT.

12/20A VAC

EMER.CKT.

FIRE ALARM INPUT PS

TYP. BRIDGE RECTIFIER

TYP. INTEGRAL DUAL SPDT

RELAY IN NORMAL STATE

S

P

M

TYPICAL ELECTRONIC STRIKE ACCESS CONTROLLED DOOR

J

PHYSICAL

ACCESS CONTROL

SYSTEM

(PACS)

PROCESSOR

DATA GATHERING

PNL (DGP)

TCP/IP CONNECTION

EXISTING EIGHTH FLOOR PACS NETWORK EQUIPMENT

ENCLOSURE LOCATED IN TELEPHONE ROOM 8A149

TYPICAL CATEGORY 6 CABLE PROVIDED BY CONTRACTOR

EXISTING CATEGORY 6 PATCH PANEL

TYPICAL CATEGORY 6 PATCH CORD

PROVIDED BY CONTRACTOR

EX FIBER TO COPPER SWITCH

TO EX CORE SWITCH

THIS RISER IS DIAGRAMMATIC ONLY AND HAS BEEN PROVIDED TO INDICATE THE GENERAL CONNECTIVITY. THE CONTRACTOR SHALL PROVIDE ALL

REQUIRED EQUIPMENT, DEVICES, OUTLETS, ETC TO PROVIDE A 100% FULLY OPERATIONAL SYSTEM AS DETAILED ON THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS

J

J

RX

RX

N/O

N/C

N/O

N/C

N/C

N/O

N/C

N/O

N/C

NOTE:

PACS SECURE DOOR WIRING DIAGRAM

Not To Scale

EXISTING FIRE ALARM

TERMINAL CABINET

NAC

AM AM

F

S

F

S

F

S

FF

F

DH

F

DH

FAV FAV FV FA FAV FAV

ELECTRICAL ROOM 8A105

B

C

C

A

2000 Market Street

Philadelphia, PA 19103

Fax (215) 568-2639

Tel (215) 568-8250

F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue

H.F. Lenz Company

Mechanical, Electrical, Fire Protection, and Plumbing Engineer

"FULLY SPRINKLERED BUILDING"

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of

Construction and Facilities

Management on e e igh th inc h = on e f oo t

B

A

C

D

E

F thr ee in ch es on e f oo t

6"

6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t

6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Suite 600

SEAL:

P M

05-JAN-2018

ES502

3900 Woodland Ave, Philadelphia, PA 19104

KEY PLAN

N

TME

RENOVATE

SPECIALTY CLINICS

642-16-106

ELECTRICAL DIAGRAMS

LOW VOLTAGE SYSTEMS

RJD

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

2000 Market Street

Philadelphia, PA 19103

Fax (215) 568-2639

Tel (215) 568-8250

F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue

H.F. Lenz Company

Mechanical, Electrical, Fire Protection, and Plumbing Engineer

"FULLY SPRINKLERED BUILDING"

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of

Construction and Facilities

Management on e e igh th inc h = on e f oo t

B

A

C

D

E

F thr ee in ch es on e f oo t

6"

6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t

6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Suite 600

SEAL:

P M

05-JAN-2018

ES601

3900 Woodland Ave, Philadelphia, PA 19104

KEY PLAN

N

TME

RENOVATE

SPECIALTY CLINICS

642-16-106

PANELBOARD SCHEDULES

RJD

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

2000 Market Street

Philadelphia, PA 19103

Fax (215) 568-2639

Tel (215) 568-8250

F: 814.269.9301 T: 814.269.9300 Johnstown, PA 15904-3314 1407 Scalp Avenue

H.F. Lenz Company

Mechanical, Electrical, Fire Protection, and Plumbing Engineer

"FULLY SPRINKLERED BUILDING"

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of

Construction and Facilities

Management on e e igh th inc h = on e f oo t

B

A

C

D

E

F thr ee in ch es on e f oo t

6"

6" on e a nd on e h alf in ch es on e f oo t on e i nc h = on e f oo t

6" 6" thr ee qu ar ter s i nc h = on e f oo t on e h alf in ch on e f oo t thr ee ei gh ths in ch on e f oo t on e q ua rte r in ch on e f oo t

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Suite 600

SEAL:

P M

05-JAN-2018

ES602

3900 Woodland Ave, Philadelphia, PA 19104

KEY PLAN

N

TME

RENOVATE

SPECIALTY CLINICS

642-16-106

LIGHTING FIXTURE SCHEDULE

RJD

AutoCAD SHX Text Dwg. of

AutoCAD SHX Text

ES401
Sheets and Views
ES401
ES402
Sheets and Views
ES402
ES501
Sheets and Views
ES501
ES502
Sheets and Views
ES502
ES601
Sheets and Views
ES601
ES602
Sheets and Views
ES602