36C24219Q0659-002.docx
DOCX document 16 KB Posted
- Attached to
- Blood Parameter Monitoring System Federal contract opportunity
- Solicitation number
- 36C24219Q0659
About this file
36C24219Q0659 36C24219Q0659_3.docx
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24219Q0659-003.docx | DOCX document | |
| 36C24219Q0659-001.pdf | ||
| 36C24219Q0659-000.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FedBizOpps Amendment to a Previous Combined Solicitation
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
BASE NOTICE TYPE
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Amendment to a Previous Combined Solicitation Rev. March 2010 Blood Parameter Monitoring System 14227 36C24219Q0659 05-08-2019 N 334510 Department of Veterans Affairs Network Contracting Office (NCO) 2 2875 Union Road Suite 3500 Cheektowaga NY 14227
STATEMENT OF WORK (SOW)
as of 5/07/19
Contract Number:
Task Order Number:
IFCAP Tracking Number:
Follow-on to Contract and Task Order Number:
1. Contracting Officer’s Representative (COR):
| Name: |
| Dr. Wiam Khadra |
| Section: |
| Cardiothoracic Surgery |
| Address: |
| 3495 Bailey Avenue, Buffalo, NY 14215 |
| Phone Number: |
| 716-862-8728 |
| Fax Number: |
| 716-862-8709 |
| E-Mail Address: |
| Wiam.Khadra@va.gov |
2. Contract Title:
VA WNYHS procurement of Terumo Blood Parameter Monitoring System for the Buffalo VA Medical Center Operating Room.
3. Background:
The Buffalo VA Medical Center requires two (2) new Blood Parameter Monitoring Systems for the Operating Room. The new Blood Parameter Monitoring Systems will be replacing older units. The new Blood Parameter Monitoring Systems are needed to manage patient Hemostasis and gases on a continuous base during Bypass period.
4. Scope:
The Buffalo VAMC is seeking to purchase two (2) new Blood Parameter Monitoring Systems that meet the clinical, functional, and performance specifications specified in this Statement of Work (SOW). The Buffalo VAMC shall only consider new, latestgeneration Blood Parameter Monitoring Systems. Refurbished or remanufactured will not meet the needs of the Buffalo VAMC. All proposals must be reviewed by clinical staff prior to award for acceptance.
5. Specific Technical Elements: The proposed Blood Parameter Monitoring Systems shall meet the following Buffalo VA Medical Center technical requirements.
5.1 The proposed CDI Blood Parameter Monitoring Systems shall be a Terumo Blood Parameter Monitoring System 550 or equivalent.
5.2 The proposed CDI Blood Parameter Monitoring System shall provide a one-year warranty.
5.3 The proposed Blood Parameter Monitoring System must use optical fluorescence technology to measure pH, pCO2, pO2, and K+ in blood.
5.4 The proposed Blood Parameter Monitoring System must include a shunt sensor with four microsensors to measure pH, pCO2, pO2, and K+ and a thermistor to measure temperature.
5.5 The proposed Blood Parameter Monitoring System must provide measurements of pH, pCO2 and pO2 every second during use.
5.6 The proposed Blood Parameter Monitoring System must provide measurements of K+ every 6 seconds during use.
5.7 The proposed Blood Parameter Monitoring System must provide measurements of SO2, Hct, and Hgb every 18 milliseconds during use.
5.8 The proposed Blood Parameter Monitoring System must include a continuous display of the measurements of pH, pCO2, pO2, and K+ in blood.
| Description |
| Item # |
| QTY |
| Terumo CDI 550 Monitor with ART/HS |
| 550AHCT |
| 2 |
| Terumo CDI Monitor Pole Clamp 7” |
| CDI517 |
| 2 |
| Terumo CDI CABLE HEAD BRACKET |
| CDI519 |
| 2 |
| Terumo CDI GAS BOTTLE A |
| CDI506 |
| 1 |
| Terumo CDI GAS BOTTLE B |
| CDI507 |
| 1 |
| Terumo CDI 540 CALIBRATOR |
| 540 |
| 1 |
6. Performance Monitoring: The offering vendor shall meet the following Buffalo VA Medical Center Terms and Conditions.
*Offering vendors shall provide complete, detailed responses to each of the following Terms and Conditions in their bid proposals.
6.1 The offering vendor shall provide two copies of the operator’s manual for the proposed Blood Parameter Monitoring System. The offering vendor shall provide any other operator (End-user) training media with the purchase of the Blood Parameter Monitoring System.
6.2 The offering vendor shall provide a listing of all Recalls, Safety Alerts and Field Engineering Change notices pertaining to the proposed Blood Parameter Monitoring System over the past 24 months.
6.3 A standard 1-year warranty shall be included with the bid proposal. Other warranty options may be detailed (offering vendors not required to do so) but should only be listed as potential options in the bid proposal.
7. Place of Performance:
The place of performance for this contract is the Buffalo VAMC.