This document is a Sources Sought notice from the Department of Veterans Affairs (VA) Connecticut Healthcare System (VACHS) for fire door field inspections and labeling services. The VACHS is seeking qualified sources to provide all labor, materials, transportation, parts, disposal, and expertise necessary to inspect and label fire doors and smoke doors at the West Haven and Newington campuses per NFPA 80 and NFPA 101 requirements. The period of performance is 120 calendar days from the notice to proceed. Interested parties are invited to submit capability statements by August 9, 2024 at 5:00 PM EST. The VA may set aside this requirement for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs), Veteran-Owned Small Businesses (VOSBs), or small businesses, or procure through full and open competition based on the responses. Respondents should provide information on their qualifications, socioeconomic status, and ability to meet the requirements in the attached Statement of Work.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VA Connecticut Healthcare System Fire Door Inspection and Labeling

SUBJECT*
Fire Door Field Labeling (VA-24-00094711)

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
03104
SOLICITATION NUMBER*
36C24124Q0803
RESPONSE DATE/TIME/ZONE
08-09-2024 17:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
15 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
J042
NAICS CODE*
541990
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

VAMC Manchester

718 Smyth Road Manchester NH 03104

POINT OF CONTACT*

Contract Specialist Nathan Langone Nathan.Langone@va.gov 603-340-0102

PLACE OF PERFORMANCE

ADDRESS
VAMC West Haven

950 Campbell Ave

West Haven CT

POSTAL CODE
06516
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

Sources Sought Notice Sources Sought Notice

DESCRIPTION

*= Required Field
Sources Sought Notice

Sources Sought Notice

This is a Sources Sought notice only. This is not a request for quotes and no contract will be awarded from this announcement. The Government will not provide any reimbursement for responses submitted in response to this Source Sought notice. Respondents will not be notified of the results of the evaluation.

If a solicitation is issued it shall be announced at a later date, and all interest parties must response to that solicitation announcement separately. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation The purpose of this announcement is to perform market research to gain knowledge of potential qualified sources and their size classification relative to NAICS 541990 (All other professional, scientific, and technical services) SBA size standard $19.5 Million. VA Connecticut Healthcare System West Haven and Newington Campuses require Fire Door compliance verification and Field Labeling of Fire Doors and Frames. VACHS is currently seeking services for all labor, materials, transportation, parts, disposal, and expertise necessary to provide required Fire Door Field Inspections and Labeling of the VACHS inventory per NFPA 80, NFPA 101. The full SOW is attached below for reference.

This Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the requirement described below. Vendors are encouraged to submit information relative to their capabilities to fulfill this requirement, in the form of a statement that addresses the specific requirement identified in this Sources Sought. Information received from this Sources Sought shall be utilized to facilitate the Contracting Officer’s review of the market base, for acquisition planning, size determination, and procurement strategy.

Submission Instructions: Interested parties who consider themselves qualified to perform the services are invited to submit a response to this Sources Sought Notice by 17:00 EST, 9th of August 2024. All responses under this Sources Sought Notice must be emailed to Nathan.Langone@va.gov with Sources Sought # 36C24124Q0803 in the subject line. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.

Interested parties should complete the attached Sources Sought Worksheet. Parties may submit additional information related to their capabilities, provided it contains all the requirements contained in the Sources Sought Worksheet. Responses to this Sources Sought shall not exceed 8 pages. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe PDF format.

Attachment 1 Sources Sought Worksheet

QUALIFICATION INFORMATION:

Company / Institute Name: _______________________________________________________ Address: ______________________________________________________________________ Phone Number: ________________________________________________________________ Point of Contact: _______________________________________________________________ E-mail Address: ________________________________________________________________ Unique Entity Identifier (UEI) #: ___________________________________________________ CAGE Code: __________________________________________________________________ SAM Registered: (Y / N) Other available contract vehicles applicable to this sources sought (GSA/FSS/NASA SEWP/ETC): __________________________________________________________________

SOCIO-ECONOMIC STATUS:

VIP Verified SDVOSB: (Y / N) VIP Verified VOSB: (Y / N) 8(a): (Y / N) HUBZone: (Y / N) Economically Disadvantaged Women-Owned Small Business: (Y / N) Women-Owned Small Business: (Y / N) Small Business: (Y / N) NOTE: Respondent claiming SDVOSB and VOSB status shall be registered and Center for Veterans Enterprise (CVE) verified in VetBiz Registry www.vetbiz.gov.

BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION.

CAPABILITY STATEMENT:

Provide a brief capability and interest in providing the service as listed in Attachment 2 Statement of Work with enough information to determine if your company can meet the requirement. The capabilities statement for this Sources Sought is not a Request for Quotation, Request for Proposal, or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach, but rather the Government is requesting a short statement regarding the company’s ability to provide the services outlined in the SOW. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement. This synopsis is for information and planning purposes only and is not to be construed as a commitment by the Government. The Government will not pay for information solicited. Respondents will not be notified of the results of the evaluation.

STATEMENT OF WORK

FIRE DOOR AND SMOKE DOOR

FIELD LABELING

BACKGROUND

VA Connecticut Healthcare System West Haven and Newington Campuses require Fire Door compliance verification and Field Labeling of Fire Doors and Frames. VACHS is currently seeking services for all labor, materials, transportation, parts, disposal, and expertise necessary to provide required Fire Door Field Inspections and Labeling of the VACHS inventory per NFPA 80, NFPA 101.

JUSTIFICATION

Veterans Health Administration (VHA) seeks to continue to improve the operational capabilities by establishing services that result in few operational delays, improved communications, increased efficiency within the facility and improve the quality of services to veterans as required by VHA Directives.

LOCATION OF SERVICES

VA Connecticut Healthcare System VACHS Fire Door and Smoke Door Field Labeling

VA Medical Center West Haven 950 Campbell Avenue West Haven, CT 06516

VA Medical Center Newington 555 Willard Avenue Newington, CT 06111

Page 1 of

PERIOD OF PERFORMANCE

The period of performance is 120 calendar days from NTP.

QUALIFICATIONS

To be considered eligible for consideration, potential bidders shall provide upon request, documentation of certified service/maintenance training on the specific equipment under the terms of this contract. The Contracting Officer and/or Contracting Officer’s Representative (COR) specifically reserve the right to reject any of the Service Provider’s personnel and refuse them permission to work on the equipment outlined herein, based upon credentials provided.

SCOPE OF WORK

The service provider shall furnish all labor, materials, equipment, tools, supervision, disposal, and all incidentals to complete the work for the services described in this document including verification and compliance of Fire Door and Smoke Door labels on existing door frames and fire doors and smoke doors identified herein Fire Door Field Labeling/Re-Labeling, and on-site training of VACHS Maintenance & Operations and Safety Department staff required per NFPA 101 and NFPA 80 (2021).

Scheduled Fire Door Field Labeling shall be completed Monday through Friday in non-critical/non-patient contact areas and buildings during regular business hours as coordinated; or Monday through Saturday outside of regular business hours after 5:00 p.m. and before 6:00 a.m. or as coordinated with the VA COR for Sunday. A minimum notice of seven (7) calendar days is required. No work shall be performed on Government Holidays unless an emergency status has been indicated by the Contracting Officer.

US Federal Holidays:

Page 1 of

New Year’s Day Martin Luther King Jr. Day President’s Day Memorial Day Juneteenth Independence Day Labor Day Columbus Day Veterans Day Thanksgiving Day Christmas Day VA Connecticut Healthcare System VACHS Fire Door Field Labeling

Service Provider shall coordinate with VA COR and Safety & Outage Coordinator to ensure that no patients are within critical patient areas and/or receiving treatment before performing work.

Work in Canteen storage areas requires coordination with Canteen Service for access and escort personnel. Areas of the Operating Room, Sterile Processing Service, and other areas considered to be Sterile may require the Service Provider to wear disposable shoe covers, overalls, and head cover.

Work in Animal Research, Pharmacy, and other Laboratory areas require coordination with designated department POC’s and requires coordination and escort personnel. Access to certain areas in laboratory and research shall be accessed by a limited number of contractors and may require completion of a confidential health questionnaire submitted to VACHS Occupational Health and the VACHS Research Department.

Operation of Fire Doors and Smoke Doors engaging or activating a local door alarm, wander guard, or fire alarm require coordination with the FMS Safety and Outage Coordinator and VA Medical Center Safety Service in Newington and West Haven.

Description of Services:

1. Service Provider shall schedule and coordinate all work with VA COR and VA Safety Designee.

2. Any required outages shall follow proper coordination and notification through the VA COR and Safety & Outage Coordinator.

3. All LOTO requests and procedures shall be in compliance with the VA Connecticut Healthcare System Medical Center Policy 138-075.

4. Service provider shall locate all fire doors and smoke doors, and once located, verify the Fire Door, Smoke Door, Frame, and any applicable labels are present. Remove any labels that are not legible, damaged, or are not deemed compliant by the inspector.

a. Apply appropriate Fire Door and Smoke Door Label(s) per NFPA 80.

b. In the event the service provider identifies inoperable latches, egress hardware, incorrect labeling, etc., the service provider shall notify the VA Contracting Officer and COR and provide a report of deficiencies identified.

c. Include a quantity of five (5) additional Fire Door and Smoke Door Labels should additional Fire Door inventory be identified by the Service Provider or the Medical Center.

5. Service provider shall recommend any updates to the Door and Hardware Schedule as required; and include fire and/or smoke doors and hardware that are not included in the base inventory if identified.

6. Service provider shall identify all fire doors that are missing labels and apply a label attached to the fire door and frame as required by NFPA 80 Section 4.2.

7. Service Provider shall perform and provide safety, supervision, PPE, and cleanup associated with completing the referenced Fire Door and Smoke Door labeling.

8. Work shall be completed in accordance with industry standard and comply with VA Regulations and code requirements to include but not limited to OSHA and NFPA.

9. A safe environment shall be always maintained. Tools, equipment, and work area shall be secure. Do not leave work site (tools, equipment, etc.) unattended or accessible by the public.

10. Prohibited equipment: Work area is within an active medical center. Equipment that uses hydrocarbon fuel, flammable fuel, and/or produces carbon monoxide exhaust are prohibited from use within the medical center or where fumes can be introduced into the medical center. At its option the Service Provider shall use either electric or electric pneumatic tools to perform the required work, if required.

11. Means of egress: Do not block any exit, discharge, or path of travel from occupied buildings.

SUBMITTALS/DELIVERABLES

1. Prior to the start of work, provide the following:

a. Site Specific Safety Plan

b. Schedule of Work Plan

c. When Hours Work Plan and Request

d. Infection Control Plan (if required)

2. Hospital furnished databases and plans shall be used as a guide for location of all Fire Doors.

a. VACHS shall furnish a current inventory of West Haven Fire Door Labeling Deficiencies Inventory.

b. VACHS shall furnish an electronic Door and Hardware Schedule for West Haven and Newington Campuses.

c. VACHS shall furnish electronic record drawings for West Haven and Newington Campuses. No current labeling deficiencies inventory is available for Newington.

3. Service Provider shall provide shop drawing(s) of both electronic and physical sample(s) of the proposed labels to be used.

4. Service Provider shall provide a written, hard copy and electronic report of inventory completed with frame and fire door and smoke door labeling. (Collectively, “Inspection Services” and “Labeling Services” reference NFPA 80, 2021).

5. Service Provider shall provide a written, hard copy and electronic report of any deficiencies discovered to the VA COR and Contracting Officer. Repairs and replacements identified in the generated report shall not be considered for modification or inclusion into this contract.

6. Service Provider shall provide two (2) hours of certified NFPA Fire and Smoke Door Inspection Training to VA Connecticut Staff at Newington and West Haven campuses.

a. on-site first shift training, two (2) one-hour onsite training sessions to be coordinated with Safety and Outage Coordinator and VACHS Safety Department for a maximum of eight (8) staff (four (4) staff at each location).

West Haven Campus Buildings Building 1: Clinical Building 2: Clinical Building 2A: NIC Building 3: NIC Building 4: NIC Building 5: NIC Building 6: NIC Building 7: NIC Building 8: NIC Building 8A: NIC Building 9: NIC Building 10: NIC

Building 11: NIC Building 11A: NIC Building 12: NIC Building 12A: NIC Fisher House: NIC Building 14A: NIC Building 15: NIC Building 15A: NIC Building 16: NIC Building 19: NIC Building 21: NIC Building 22: NIC

Building 24: NIC Building 27: NIC Building 32: NIC Building 34: NIC Building 35: NIC Building 35A: NIC Building 36: NIC Building 36A: NIC Building 38: NIC Building 39: NIC Building 50: NIC

PER

FISHER HOUSE

West Haven Campus Map: Not to Scale

West Haven Deficiencies

Bldg
Floor
Room/Location
1
1
SG
SG-178 DBL wood doors across from Mason Cage.
2
1
SG
Alarm activated doors by freight elevators.
3
1
SG
Stairwell #7 behind MRI
4
1
1st
Alarm activated DBL doors into kitchen by G286
5
1
1st
Alarm activated DBL doors by G285
6
1
1st
Exterior door by G220
7
1
2nd
Magnetic hold open doors 2155
8
1
2nd
Magnetic hold open DBL doors elevator, loppy (North)
9
1
2nd
Freight elevator doors
10
1
2nd
2212-A back of break room stair to OR
11
1
3rd
freight elevator doors
12
1
3rd
Alarm activated doors by Scrub rm 4+6 OR
13
1
4th
DBL doors next to 4212
14
1
4th
Freight elevators doors 4th Floor
15
1
5th
Freight elevators doors 5th Floor
16
1
5th
Alarm activated doors next to stair #3 5 (East)
17
1
5th
Magnetic hold open DBL doors by 5156
18
1
5th
DBL doors by 5187 (West)
19
1
5th
DBL doors by 5187 (West)
20
1
6th
Freight elevators doors
21
1
6th
Magnetic hold open DBL doors by 6104
22
1
7th
Freight elevators doors
23
1
8th
DBL door w/magnetic hold open by 8119
24
1
8th
DBL door w/magnetic hold open by 8132
25
1
8th
DBL door w/magnetic hold open by 8121
26
1
8th
DBL door w/magnetic by elevator p5
27
1
9th
Freight elevator doors
28
1
9th
Entry into 9 East by 9101
29
1
9th
Stair #3
30
1
9th
Alarm activated door by 9128 (East)
31
2
Ground
Bld 2- Opposite G143C (Labor shop)
32
2
Ground
Alarm activated doors at the bottom of comp from Bld 4
33
2
Ground
Dialysis entry way.
34
2
Ground
Stair #3- below main revolving door entry.
35
2
Ground
Adjacent to G1438 stair exit.
36
2
Ground
Passenger elevator lobby, GF adjacent to G138
37
2
Ground
G143A
38
2
Ground
G142B-2. SPD storage.
39
2
Ground
G145A- Inside g145 load center
40
2
Ground
G-104-2
41
2
Ground
G-127H-2
42
2
Ground
Stair #2, Police locker room
43
2
1st
Stair #3 (Near revolving entry lobby, opposite of Audiology)
44
2
1st
Audiology
45
2
1st
Audiology rear exit. Stair way #6 egress
46
2
1st
Adjacent to blood draw+cashier
47
2
1st
Near 1302, next to old PIV office area.
48
2
1st
Near 1321-2. Next door to police office.
49
2
1st
Rehab clinic entry way
50
2
1st
Rehab rear door.
51
2
1st
Room 1004, stair # 4 exit rear courtyard egress.
52
2
1st
Room 1263+barbershop
53
2
1st
Next to 1204 Exam room (for West side of firm A)
54
2
1st
Bld 2- first floor DF
55
2
1st
Near triage nurse station, adjacent to 1124
56
2
1st
1st floor main off corridor inside old phych ER
57
2
1st
1122-2 Audiology
58
2
1st
1175-1
59
2
1st
1162A- Behind triage
60
2
1st
1151-2- Med ER
61
2
1st
1149- Med ER
62
2
1st
1141-2
63
2
1st
1336-2
64
2
1st
1337-2
65
2
1st
1338- b-2
66
2
1st
1340-2
67
2
1st
1331-2
68
2
1st
1292-2 Physical Therapy
69
2
1st
1187-2
70
2
1st
Firm A
71
2
1st
Firm A
72
2
1st
1253-2
73
2
1st
1269-2
74
2
1st
1273-2
75
2
1st
1279 A
76
2
2nd
Opening 2107-Main entrance to Donaldson Center
77
2
2nd
2001A Stair #3. 2nd floor door
78
2
2nd
Stair #6- 2nd floor. Donaldson- adjacent to 2107 D
79
2
2nd
2001A Stair #3
80
2
2nd
Stair #2. 2nd floor near 2243 Vision close to service elevator.
81
2
2nd
Stair #2 2nd floor near TB lab next to 2214
82
2
2nd
Bld 2 2nd floor near 2229 by firm B
83
2
2nd
Bld 2 2nd fl near 2205 by ramp
84
2
2nd
Stair #7 2nd floor firm B back office b/t 2180-2163
85
2
2nd
Bld 2, 2nd fl near Pharmacy next to 2122 (passanger close to elevators)
86
2
2nd
2001 stair #1- bld 2, 2nd floor in Pharmacy.
87
2
2nd
2102-2
88
2
2nd
2107 D-2 Donaldson
89
2
2nd
2107 C A- Donaldson
90
2
2nd
2104 F-2 Pharmacy
91
2
2nd
2120-2 Dental
92
2
2nd
2116-2 Dental
93
2
2nd
2145 A
94
2
2nd
2183-2
95
2
2nd
2185 A
96
2
2nd
2230 B-2
97
2
2nd
2202-2
98
2
2nd
2220 A TB lab
99
2
2nd
2207-2 by wellness center.
100
2
2nd
2189 Firm B
101
2
3rd
Stair #4
102
2
3rd
Near 3100
103
2
3rd
Stair #5
104
2
3rd
Stair #2
105
2
3rd
Adjacent to 3161
106
2
3rd
Stair #2
107
2
3rd
Stair#3
108
2
3rd
3238-2
109
2
3rd
3228 A
110
2
3rd
3133-2
111
2
3rd
3109-2
112
2
3rd
3132-2
113
2
3rd
3170-2
114
2
3rd
3186-2
115
2
3rd
3196-2
116
2
3rd
3213-2
117
2
3rd
3236-2
118
2
4th
Bld 2 4th floor- stair #4 opposite of 4132
119
2
4th
4th floor double doors leading into west exam area opposite electric closet 4195
120
2
4th
4168-2
121
2
4th
4169-2 soiled utility room
122
2
4th
4165-2
123
2
4th
4213-2
124
2
4th
4222-2
125
2
4th
4100-2
126
2
4th
4151-2
127
2
4th
4150-2
128
2
4th
4109-2
129
2
4th
4123-2
130
2
5th
Adjacent to 5190 cancer center
131
2
5th
Stair #1
132
2
5th
Adjacent to 5212 North
133
2
5th
Adjacent to 5182
134
2
5th
5222-2
135
2
5th
5218-2
136
2
5th
5165-2
137
2
5th
5224-2
138
2
7th
7230-2
139
2
7th
7160-2
140
2
7th
7166-2
141
2
7th
7131-2
142
2
7th
7125-2
143
2
7th
7227-2
144
2
8th
Passenger elevator lobby.
145
2
8th
8145-2
146
2
8th
8132-2
147
2
8th
8138-2
148
2
8th
8102 airshafts

Newington Campus Buildings

Building 1: Clinical Building 2C: Clinical Building 2E: Admin/Clinical Building 2W: Clinical Building 3: Engineering Building 4: NIC Building 6: NIC Building 7: NIC Building 8: NIC Building 11: Engineering Building 12: Engineering Building 14: NIC Building 21: NIC Building 30: NIC Building 32: Admin

Building 33: NIC Building 34: NIC Building 42: NIC Building 46: NIC Building 50: NIC Building 64: NIC Building 65: NIC Building 168: NIC

Page 1 of

Victory Gardens Not in Contract )Newington Campus Map: Not to Scale

SPECIAL INSTRUCTIONS

All Service Provider personnel, sub-contractors and representatives visiting VA sites will be required to sign in upon arrival at Building 15 in West Haven and/or the 3rd Floor of Building 3 in Newington and/or retain a temporary VA badge. Each visiting individual be required to enter their name, their company’s name, VA project title, reason for visit, and the times of arrival and departure. Arrangements for after normal hour working site visits must be made in advance and during normal working hours.

A. General: The Contracting Officer reserves the right to terminate any services, without payment for services completed, if such services are not needed or are not being adequately completed.

B. Approved Plans and Permits: Prior to the start of work, submit to VA copies of all required permits.

C. Site Visits: Day to day administration will be performed by the COR. Periodic reviews, tests, and other field observation by the Government are not to be interpreted as superintendence nor as resulting in any approval of the Service Provider’s apparent progress toward meeting the Government’s objectives; but are intended to discover any information that the Contracting Officer may be able to call to the Service Provider’s attention to prevent costly misdirection of effort.

The Service Provider shall provide VA with a copy of all inspection reports for inspections conducted by local, regional, and state code authorities from the start of construction through issuance of the certificate of occupancy or completion.

D. The Service Provider shall develop and provide to the VA the following:

a. Safety Plan: The Service Provider shall produce work in accordance with the latest editions of all applicable VHA guidelines (e.g. Standards, Master Specifications, Standard Details, Special Design Criteria to meet Hospital Joint Commission (TJC) requirements), NFPA, Federal and State codes pertinent to the project scope.

b. Schedule of Work Plan.

c. When Hours Work Plan and Request.

d. Infection Control Plan.

E. All applicable personnel on site are required to obtain an Occupational Safety and Health Administration (OSHA) 10 hour certification, and the site competent person for the Service Provider must obtain an OSHA 30 hour construction certification.

F. Per VA Directive 1805, smoking vaping, and smokeless tobacco are prohibited on the grounds of VA facilities, including in vehicles. This Directive applies to all Service providers and their employees.

G. No photography of VA premises is allowed without written permission of the contracting officer. Patients and staff are not to be photographed at any time.

H. Parking for Service provider and its employees shall be in designated areas only. Service provider to coordinate with COR.

I. The Service provider shall confine all operations (including storage of materials) on government premises to areas authorized or approved by the VA Contracting Officer. The Service provider shall hold and save the government, its officers, and agents, free and harmless from liability of any nature occasioned by the Service provider’s performance. Working space and space available for storing materials shall be as determined by the COR. Workers are subject to the rules of the Medical Center applicable to their conduct. Execute work in such a manner as to reduce impacts with work being done by others.

J. Billing: Provide COR with a report or statement of work completed and include statements with request for payment. Statement should include service completed and the date each service item was completed. Labor charges shall be billed hourly, and any unused labor totals will be credited back to the VA Medical Center on the next billing cycle, upon receipt of the service report.

Safety Codes / Certification / Licensing:

Environmental abatement work, if necessary, is to be performed by Service Provider under supervision and monitoring for the VA by a Certified Industrial Hygienist.

The Service Provider shall comply with all codes as described above, as well as codes customarily applied in VA construction jobs such as NFPA fire code, OSHA, VA Design Guides, etc. Labs used by the Service Provider shall be licensed as required by any applicable governing agencies, and their certifications and licenses shall be included in the reports.

Travel:

Service Provider and/or subcontractors will travel from their place of business to the West Haven and Newington VA Medical Center of the VA Connecticut Healthcare Syste image1.emf image2.emf

File details come from the government source that posted it. Updated .