36C24119R0052-0001007.pdf
PDF 5 MB Posted
- Attached to
- Project # 650-07-102: Pavement Repairs Federal contract opportunity
- Solicitation number
- 36C24119R0052
About this file
36C24119R0052 0001 S02 Drawings_Part5.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24119R0052-0003000.docx | DOCX document | |
| 36C24119R0052-0002000.docx | DOCX document | |
| 36C24119R0052-0002001.pdf | ||
| 36C24119R0052-0001003.pdf | ||
| 36C24119R0052-0001002.docx | DOCX document | |
| 36C24119R0052-0001005.pdf | ||
| 36C24119R0052-0001004.pdf | ||
| 36C24119R0052-0001006.pdf | ||
| 36C24119R0052-013.pdf | ||
| 36C24119R0052-011.pdf | ||
| 36C24119R0052-009.docx | DOCX document | |
| 36C24119R0052-012.pdf | ||
| 36C24119R0052-010.pdf | ||
| 36C24119R0052-000.docx | DOCX document |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STORMWATER DETAILS-1
C-508
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FINAL SUBMISSION
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
AI ENGINEERS INC.
919 MIDDLE STREET
MIDDLETOWN, CT 06457
(860) 635-7740
GEOTECHNICAL ENGINEERING
GEI Consultants, Inc.
44 Winding Brook Drive Glastonbury, CT 06033 860-368-5300
VAMC PROVIDENCE, RI
FCA PAVEMENT REPAIRS
AIR FORCE DRIVE
PROVIDENCE, R.I.
650-07-102
Project Director
2/21/2018 MR/RG MLRevisions: Date:
35% DESIGN 10/13/17
60% DESIGN 12/12/17
100% DESIGN 02/01/18
ELECTRICAL ABBREVIATIONS DIAGRAM SYMBOLS POWER SYMBOLS
LIGHTING SYMBOLS
COMMUNICATION SYMBOLS
SAFETY AND SECURITY SYMBOLS
OC
NOTES
DRAWING SYMBOLS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FINAL SUBMISSION
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
AI ENGINEERS INC.
919 MIDDLE STREET
MIDDLETOWN, CT 06457
(860) 635-7740
GEOTECHNICAL ENGINEERING
GEI Consultants, Inc.
44 Winding Brook Drive Glastonbury, CT 06033 860-368-5300
VAMC PROVIDENCE, RI
FCA PAVEMENT REPAIRS
AIR FORCE DRIVE
PROVIDENCE, R.I.
650-07-102
Project Director
2/21/2018 MR/RG MLRevisions: Date:
35% DESIGN 10/13/17
60% DESIGN 12/12/17
100% DESIGN 02/01/18
ELECTRICAL NOTES,
SYMBOLS & ABBREVIATIONS
E-001
AutoCAD SHX Text 1PH SINGLE PHASE SINGLE PHASE 3PH THREE PHASE THREE PHASE 1/C ONE CONDUCTOR ONE CONDUCTOR 2/C TWO CONDUCTOR TWO CONDUCTOR 3/C THREE CONDUCTOR THREE CONDUCTOR 4/C FOUR CONDUCTOR FOUR CONDUCTOR 4W FOUR WIRE FOUR WIRE 1P ONE POLE ONE POLE 2P TWO POLE TWO POLE 3P THREE POLE THREE POLE 4P FOUR POLE FOUR POLE A/C UNIT AIR CONDITIONING UNIT AIR CONDITIONING UNIT A/E ARCHITECT/ENGINEER ARCHITECT/ENGINEER AC ALTERNATING CURRENT OR ARMORED ALTERNATING CURRENT OR ARMORED CABLE ADDL ADDITIONAL ADDITIONAL ADJ ADJACENT ADJACENT AF AMPERE FRAME AMPERE FRAME AFC ABOVE FINISHED COUNTER ABOVE FINISHED COUNTER AFF ABOVE FINISHED FLOOR ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE ABOVE FINISHED GRADE AHJ AUTHORITY HAVING JURISDICTION AUTHORITY HAVING JURISDICTION AIC AMPERE INTERRUPTING CAPACITY AMPERE INTERRUPTING CAPACITY ALT ALTERNATE ALTERNATE AMB AMBIENT AMBIENT AMP OR A AMPERE AMPERE ARCH ARCHITECT ARCHITECT AT AMPERE TRIP AMPERE TRIP ATS AUTOMATIC TRANSFER SWITCH AUTOMATIC TRANSFER SWITCH AUTO AUTOMATIC AUTOMATIC AV AUDIO VISUAL AUDIO VISUAL BAT BATTERY BATTERY BFF BELOW FINISH FLOOR BELOW FINISH FLOOR BIL BASIC INSULATION LEVEL BASIC INSULATION LEVEL BLDG BUILDING BUILDING BYP BY PASS BY PASS C CONDUIT CONDUIT CATV COMMUNITY ANTENNA TELEVISION COMMUNITY ANTENNA TELEVISION CCTV CLOSED CIRCUIT TELEVISION CLOSED CIRCUIT TELEVISION cd CANDELA CANDELA CD CONSTRUCTION DOCUMENTS CONSTRUCTION DOCUMENTS CHW CHILLED WATER CHILLED WATER CHWP CHILLED WATER PUMP CHILLED WATER PUMP CKT CIRCUIT CIRCUIT C/B CIRCUIT BREAKER CIRCUIT BREAKER CLF CURRENT LIMITING FUSE CURRENT LIMITING FUSE CLG CEILING CEILING COAX COAX CABLE COAX CABLE COMM COMMUNICATION COMMUNICATION CPT CONTROL POWER TRANSFORMER CONTROL POWER TRANSFORMER CRI COLOR RENDERING INDEX COLOR RENDERING INDEX CT CURRENT TRANSFORMER CURRENT TRANSFORMER CTV CABLE TELEVISION CABLE TELEVISION CU COPPER COPPER CF CUBIC FEET CUBIC FEET db DECIBELS DECIBELS DC DIRECT CURRENT DIRECT CURRENT DEG C DEGREES CELSIUS DEGREES CELSIUS DEG F DEGREES FAHRENHEIT DEGREES FAHRENHEIT DEMO DEMOLITION DEMOLITION DISC DISCONNECT DISCONNECT DISTR PNL DISTRIBUTION PANEL DISTRIBUTION PANEL DN DOWN DOWN DPDT DOUBLE POLE, DOUBLE THROW DOUBLE POLE, DOUBLE THROW DPST DOUBLE POLE, SINGLE THROW DOUBLE POLE, SINGLE THROW DS DOOR SWITCH DOOR SWITCH DISC. SW DISCONNECT SWITCH DISCONNECT SWITCH DWG DRAWING DRAWING EL ELEVATION ELEVATION ELEC ELECTRIC OR ELECTRICAL ELECTRIC OR ELECTRICAL ELEV ELEVATOR ELEVATOR EMER EMERGENCY EMERGENCY EMI ELECTROMAGNETIC INTERFERENCE ELECTROMAGNETIC INTERFERENCE EMT ELECTRICAL METALLIC TUBING ELECTRICAL METALLIC TUBING ENCL ENCLOSURE ENCLOSURE EPO EMERGENCY POWER OFF EMERGENCY POWER OFF ER EXISTING TO REMAIN EXISTING TO REMAIN EWC ELECTRIC WATER COOLER ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER ELECTRIC WATER HEATER EXIST EXISTING EXISTING EXP EXPLOSION PROOF EXPLOSION PROOF FA FIRE ALARM FIRE ALARM FAAP FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FIRE ALARM CONTROL PANEL FC FOOTCANDLE FOOTCANDLE FIXT FIXTURE FIXTURE FLA FULL LOAD AMPS FULL LOAD AMPS FMC FLEXIBLE METAL CONDUIT FLEXIBLE METAL CONDUIT FLUOR FLUORESCENT FLUORESCENT FT FEET OR FOOT FEET OR FOOT FVNR FULL VOLTAGE NON-REVERSING FULL VOLTAGE NON-REVERSING FVR FULL VOLTAGE REVERSING FULL VOLTAGE REVERSING G OR GND GROUND GROUND GEN GENERATOR GENERATOR GFCI GROUND FAULT CIRCUIT GROUND FAULT CIRCUIT INTERRUPTER HID HIGH INTENSITY DISCHARGE HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTOMATIC HAND-OFF-AUTOMATIC HP HORSEPOWER HORSEPOWER HT HEIGHT HEIGHT HZ HERTZ HERTZ IESNA ILLUMINATION ENGINEERING SOCIETY ILLUMINATION ENGINEERING SOCIETY OF NORTH AMERICA IMC INTERMEDIATE METAL CONDUIT INTERMEDIATE METAL CONDUIT INCAND INCANDESCENT INCANDESCENT IR INFRARED INFRARED IWH INSTANTANEOUS WATER HEATERINSTANTANEOUS WATER HEATER
AutoCAD SHX Text J-BOX JUNCTION BOX JUNCTION BOX k KILO KILO kV KILOVOLT KILOVOLT kVA KILOVOLT AMPERE KILOVOLT AMPERE kVAH KILOVOLT AMPERE PER HOUR KILOVOLT AMPERE PER HOUR kVAR KILOVOLT AMPERE REACTIVE KILOVOLT AMPERE REACTIVE kW KILOWATT KILOWATT kWH KILOWATT HOUR KILOWATT HOUR LED LIGHT EMITTING DIODE LIGHT EMITTING DIODE LF LINEAR FEET (FOOT) LINEAR FEET (FOOT) LM LUMEN LUMEN LPS LOW PRESSURE SODIUM LOW PRESSURE SODIUM LRA LOCKED ROTOR AMPS LOCKED ROTOR AMPS LTG LIGHTING LIGHTING LTG PNL LIGHTING PANEL LIGHTING PANEL LV LOW VOLTAGE LOW VOLTAGE MATV MASTER ANTENNA TELEVISION MASTER ANTENNA TELEVISION SYSTEM MAX MAXIMUM MAXIMUM MC METAL CLAD CABLE METAL CLAD CABLE MCA MINIMUM CIRCUIT AMPS MINIMUM CIRCUIT AMPS MCB MAIN CIRCUIT BREAKER MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MAIN DISTRIBUTION PANEL MECH MECHANICAL MECHANICAL MH MANHOLE MANHOLE MIN MINIMUM MINIMUM MOCP MAXIMUM OVERCURRENT PROTECTION MAXIMUM OVERCURRENT PROTECTION MLO MAIN LUGS ONLY MAIN LUGS ONLY MTD MOUNTED MOUNTED MTS MANUAL TRANSFER SWITCH MANUAL TRANSFER SWITCH MV MEDIUM VOLTAGE MEDIUM VOLTAGE MVA MEGAVOLT-AMPERE MEGAVOLT-AMPERE MW MEGAWATT MEGAWATT NA NOT APPLICABLE NOT APPLICABLE NEC NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NEUT OR N NEUTRAL NEUTRAL NFPA NATIONAL FIRE PROTECTION NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NOT IN CONTRACT NL NIGHT LIGHT NIGHT LIGHT NO NORMALLY OPEN NORMALLY OPEN NTS NOT TO SCALE NOT TO SCALE OC ON CENTER ON CENTER OD OUTSIDE DIAMETER OUTSIDE DIAMETER OL OVERLOAD OVERLOAD P POLE POLE PA PUBLIC ADDRESS PUBLIC ADDRESS PB PUSHBUTTON PUSHBUTTON PCB POLYCHLORINATED BIPHENYL POLYCHLORINATED BIPHENYL PC PHOTOELECTRIC CELL PHOTOELECTRIC CELL PED PEDESTAL PEDESTAL PEND PENDANT PENDANT PF POWER FACTOR POWER FACTOR PH PHASE PHASE PNL PANEL PANEL PT POTENTIAL TRANSFORMER POTENTIAL TRANSFORMER PVC POLYVINYL CHLORIDE (PLASTIC) POLYVINYL CHLORIDE (PLASTIC) PWR POWER POWER RCP REFLECTED CEILING PLAN REFLECTED CEILING PLAN RE REMOVE EXISTING REMOVE EXISTING REC RECESSED RECESSED RECPT RECEPTACLE RECEPTACLE RL RELOCATE EXISTING RELOCATE EXISTING RM ROOM ROOM RMC/RGS GALVANIZED RIGID METAL CONDUIT GALVANIZED RIGID METAL CONDUIT RMS ROOT MEAN SQUARE ROOT MEAN SQUARE REQ REQUIRED REQUIRED SD SMOKE DETECTOR SMOKE DETECTOR SF SQUARE FOOT (FEET) SQUARE FOOT (FEET) SHT SHEET SHEET SPEC SPECIFICATION SPECIFICATION SPST SINGLE POLE, SINGLE THROW SINGLE POLE, SINGLE THROW SURF SURFACE SURFACE SW SWITCH SWITCH SWBD SWITCHBOARD SWITCHBOARD SWGR SWITCHGEAR SWITCHGEAR TC TIME CLOCK TIME CLOCK TEL TELEPHONE TELEPHONE TP TWISTED PAIR TWISTED PAIR TPS TWISTED PAIR SHIELDED TWISTED PAIR SHIELDED TV TELEVISION TELEVISION TYP TYPICAL TYPICAL UG UNDERGROUND UNDERGROUND UL UNDERWRITERS LABORATORY UNDERWRITERS LABORATORY UON UNLESS OTHERWISE NOTED UNLESS OTHERWISE NOTED UNO UNLESS NOTED OTHERWISE UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY UNINTERRUPTIBLE POWER SUPPLY V VOLT VOLT VFD VARIABLE FREQUENCY DRIVE VARIABLE FREQUENCY DRIVE VOLT VOLTAGE VOLTAGE W WATT WATT WH WATER HEATER WATER HEATER WP WEATHERPROOF WEATHERPROOF XFER TRANSFER TRANSFER XFMR TRANSFORMER TRANSFORMER
AutoCAD SHX Text
SWITCH, MULTIPOSITION
AutoCAD SHX Text
FUSE WITH RATING
AutoCAD SHX Text
NORMALLY CLOSED RELAY CONTACT
AutoCAD SHX Text
NORMALLY OPEN RELAY CONTACT
AutoCAD SHX Text
MOLDED CASE CIRCUIT BREAKER
AutoCAD SHX Text
LOW-VOLTAGE DRAWOUT AIR CIRCUIT BREAKER
AutoCAD SHX Text
HIGH-VOLTAGE DRAWOUT AIR CIRCUIT BREAKER
AutoCAD SHX Text
SWITCH AND FUSE UNIT
AutoCAD SHX Text
FUSED DRAWOUT POTENTIAL TRANSFORMER
AutoCAD SHX Text
MOTOR, SINGLE-PHASE
AutoCAD SHX Text
MOTOR, THREE-PHASE
AutoCAD SHX Text
DELTA CONNECTION
AutoCAD SHX Text
TRANSFORMER
AutoCAD SHX Text
WYE CONNECTION
AutoCAD SHX Text
EARTH GROUND
AutoCAD SHX Text
FUSIBLE LINK
AutoCAD SHX Text
GENERATOR, POWER
AutoCAD SHX Text G
AutoCAD SHX Text
BATTERY
AutoCAD SHX Text
CAPACITOR
AutoCAD SHX Text
LIGHTNING ARRESTOR
AutoCAD SHX Text RELAY 50 = INSTANTANEOUS OVERCURRENT 51 = TIME OVERCURRENT 67 = DIRECTIONAL OVERCURRENT 86 LOCK OUT
AutoCAD SHX Text R
AutoCAD SHX Text
AutoCAD SHX Text
POTHEAD
AutoCAD SHX Text
STRESS CONE
AutoCAD SHX Text
METER
AutoCAD SHX Text
AMMETER
AutoCAD SHX Text
VOLTMETER
AutoCAD SHX Text
WATTMETER
AutoCAD SHX Text
WATT-HOUR METER
AutoCAD SHX Text
TIME CLOCK
AutoCAD SHX Text
TC
AutoCAD SHX Text DISCONNECT SWITCH, FUSED 3 POLE W/SOLID NEUTRAL UON; "20" INDICATES FUSE SIZE; "30" INDICATES FRAME SIZE
AutoCAD SHX Text
DISCONNECT SWITCH, UNFUSED 3 POLE W/SOLID NEUTRAL UON; "30" INDICATES FRAME SIZE
AutoCAD SHX Text COMBINATION MOTOR CONTROLLER WITH FUSED DISCONNECT SWITCH; 3 POLE WITH THERMAL OVERLOADS UON; "2" INDICATES NEMA SIZE; "20" INDICATES FUSE SIZE; "30" INDICATES FRAME SIZE
AutoCAD SHX Text
MOTOR CONTROLLER, 3 POLE WITH THERMAL OVERLOADS UON; "3" INDICATES NEMA SIZE
AutoCAD SHX Text
VENTILATOR OR FAN COIL UNIT OUTLET
AutoCAD SHX Text CONDUIT TERMINATED 6" AFF IN STANDARD BOX FOR EXTENSION TO EQUIPMENT AS DIRECTED.
AutoCAD SHX Text CONDUIT TERMINATED W/COUPLING (FLUSH W/FINISHED FLOOR) FOR EXTENSION TO EQUIPMENT AS DIRECTED.
AutoCAD SHX Text
JUNCTION BOX
AutoCAD SHX Text
TRANSFORMER, CHARACTERISTICS AS SCHEDULED OR AS SHOWN ON THE ONE LINE DRAWING
AutoCAD SHX Text T
AutoCAD SHX Text J
AutoCAD SHX Text
MOTOR, SINGLE-PHASE
AutoCAD SHX Text
MOTOR, THREE-PHASE
AutoCAD SHX Text
EARTH GROUND
AutoCAD SHX Text
BRANCH CIRCUIT HOMERUN.
AutoCAD SHX Text
PB
AutoCAD SHX Text
PULL BOX
AutoCAD SHX Text
FLOOR OUTLET, DATA COMMUNICATION
AutoCAD SHX Text
OUTLET, DATA COMMUNICATION
AutoCAD SHX Text
PUSH BUTTON
AutoCAD SHX Text
DP#__
AutoCAD SHX Text
DISTRIBUTION PANEL
AutoCAD SHX Text
LP
AutoCAD SHX Text
LIGHTING PANEL
AutoCAD SHX Text
PANELBOARD CABINET, FLUSH MOUNTED
AutoCAD SHX Text
PANELBOARD CABINET, SURFACE MOUNTED
AutoCAD SHX Text
RECEPTACLE, CLOCK HANGER
AutoCAD SHX Text
RECEPTACLE, DUPLEX
AutoCAD SHX Text
RECEPTACLE, DUPLEX ON EMERGENCY POWER
AutoCAD SHX Text
RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER
AutoCAD SHX Text
GFI
AutoCAD SHX Text
RECEPTACLE, QUADRAPLEX
AutoCAD SHX Text
RECEPTACLE, SINGLE
AutoCAD SHX Text
RECEPTACLE, SINGLE WITH SWITCH
AutoCAD SHX Text S
AutoCAD SHX Text RECEPTACLE, SPECIAL PURPOSE A = 120V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 5-20R. B = 208V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 6-20R. C = 120V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 5-30R. D = 208V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 6-30R. E = 208V, 60A, 1 PHASE, 3-POLE, 4W, NEMA 14-60R. F = 208V, 30A, 3 PHASE, 3-POLE 4W, NEMA 15-30R. G = 208V, 50A, 3 PHASE, 3 POLE, 4W, NEMA 15-30R. H = 208V, 60A, 3 PHASE, 3 POLE, 4W, NEMA 15-60R.
AutoCAD SHX Text S
AutoCAD SHX Text
RECEPTACLE, SWITCHED DUPLEX
AutoCAD SHX Text
HVS
AutoCAD SHX Text
HI VOLTAGE SWITCH ON CONCRETE PAD
AutoCAD SHX Text DROP CORD, SINGLE CONVENIENCE OUTLET, 3-WIRE, GROUNDING TYPE, 20A, W/#12 CONDUCTORS IN FLEXIBLE CORD (CENTER LINE OF OUTLET: 6'-6" AFF. MINIMUM).
AutoCAD SHX Text SURFACE MTD WIREWAY (OUTLETS ON 2'-0" CENTERS OR AS INDICATED), MTD 3'-6" AFF OR AS INDICATED.
AutoCAD SHX Text
3-GANG COMPARTMENT BOX IN FLOOR FOR TELEPHONE, DATA & RECEPTACLE.
AutoCAD SHX Text SWITCH F = FUSED SWITCH K = KEY OPERATED K = KEY OPERATED L = LOCK LM= LOW VOLTAGE MASTER LM= LOW VOLTAGE MASTER M = MANUAL MOTOR STARTER MC= MOMENTARY CONTACT MC= MOMENTARY CONTACT (W/THERMAL OVERLOADS) P = WITH PILOT LIGHT P = WITH PILOT LIGHT PB= PUSH BUTTON STATION RC= REMOTE CONTROL RC= REMOTE CONTROL WP= WEATHER PROOF X = EXPLOSION PROOFX = EXPLOSION PROOF
AutoCAD SHX Text M
AutoCAD SHX Text VARIABLE FREQUENCY DRIVE W/ DISCONNECT SWITCH, OVERCURRENT PROTECTION & ELECTRONIC OVERLOADS UON; "10" INDICATES HP RATING
AutoCAD SHX Text LIGHT SWITCH BLANK = SINGLE POLE 2 = DOUBLE POLE 2 = DOUBLE POLE 3 = THREE-WAY 4 = FOUR-WAY 4 = FOUR-WAY D = DIMMER K = KEY OPERATED K = KEY OPERATED LV= LOW VOLTAGE L = LOCK L = LOCK LM= LOW VOLTAGE MASTER P = WITH PILOT LIGH P = WITH PILOT LIGH PB= PUSH BUTTON STATION RC= REMOTE CONTRO RC= REMOTE CONTRO T = TIMER OPERATED WP= WEATHER PROOF WP= WEATHER PROOF X = EXPLOSION PROOF OC= OCCUPANCY OC= OCCUPANCY SENSOR
AutoCAD SHX Text
AutoCAD SHX Text
LIGHT FIXTURE, CEILING SURFACE/RECESSED, LETTER INDICATES TYPE
AutoCAD SHX Text
LIGHT FIXTURE, RECESSED, LETTER INDICATES TYPE.
AutoCAD SHX Text
LIGHT FIXTURE, SURFACE MTD, LETTER INDICATES TYPE.
AutoCAD SHX Text
LIGHT FIXTURE, EMERGENCY; LETTER INDICATES TYPE.
AutoCAD SHX Text
LIGHTING, ONE HEAD EMERGENCY BATTERY POWER
AutoCAD SHX Text
LIGHT POLE, ONE LUMINAIRE
AutoCAD SHX Text
LIGHTING, EXTERIOR BUILDING
AutoCAD SHX Text
LIGHTING, TWO HEAD EMERGENCY BATTERY POWER
AutoCAD SHX Text
LIGHTING, THREE HEAD EMERGENCY BATTERY POWER
AutoCAD SHX Text
EXTERIOR FLOOD LIGHT
AutoCAD SHX Text
EXIT SIGN, WALL MOUNTED WITH DIRECTIONAL ARROWS AND FACES AS SHOWN
AutoCAD SHX Text
EXIT SIGN, CEILING MOUNTED WITH DIRECTIONAL ARROWS AND FACES AS SHOWN
AutoCAD SHX Text
LIGHT TRACK WITH HEADS AS SHOWN
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text
LIGHT FIXTURE, STRIP/INDUSTRIAL FLUORESCENT; LETTER INDICATES TYPE.
AutoCAD SHX Text
LIGHT FIXTURE, WALL MOUNTED
AutoCAD SHX Text
LIGHT FIXTURE, BOLLARD
AutoCAD SHX Text
LIGHT POLE, TWO LUMINAIRES
AutoCAD SHX Text
CABLE TELEVISION LINE
AutoCAD SHX Text
CLOSED CIRCUIT TELEVISION LINE, MINIMUM 1" CONDUIT MINIMUM 1" CONDUIT
AutoCAD SHX Text
FIBEROPTICS LINE, MIMIMUM 1" CONDUIT
AutoCAD SHX Text
TELEPHONE LINE, MINIMUM 1" CONDUIT
AutoCAD SHX Text
TELECOMMUNICATIONS MANHOLE
AutoCAD SHX Text
SECURITY ACCESS, ANNUNCIATOR PANEL
AutoCAD SHX Text SECURITY ACCESS, VIDEO CAMERA WITH LENS F = FIXED MOUNT M = MOTION DETECTOR PZ = PAN AND ZOOM PTZ= PAN, TILT, AND ZOOM WP = WEATHERPROOF HOUSING
AutoCAD SHX Text
ALARM, FIRE, COMMUNICATOR
AutoCAD SHX Text ALARM, FIRE, PANEL; LETTERS INDICATE AS FOLLOWS: FACC = CENTRAL CONSOLE FACP = CONTROL PANEL FACP = CONTROL PANEL MFACP= MASTER CONTROL PANEL FAAP = ANNUNCIATOR FAAP = ANNUNCIATOR PANEL
AutoCAD SHX Text
ALARM, FIRE, MANUAL PULL STATION
AutoCAD SHX Text
ALARM, GONG
AutoCAD SHX Text
ALARM, HORN/LIGHT, ONE ASSEMBLY
AutoCAD SHX Text
ALARM, HORN/LIGHT, ONE ASSEMBLY WITH CHIME
AutoCAD SHX Text
ALARM, HORN/LIGHT, SEPARATE ASSEMBLY
AutoCAD SHX Text
ALARM, LAMP LIGHT, SIGNAL LIGHT, STROBE
AutoCAD SHX Text
ALARM, MANUAL CONTROL
AutoCAD SHX Text
ALARM, MINI HORN
AutoCAD SHX Text
ALARM, SPRINKLER SYSTEM WATER FLOW BELL
AutoCAD SHX Text
ALARM, FLOW SWITCH
AutoCAD SHX Text
WB
AutoCAD SHX Text
AP
AutoCAD SHX Text M
AutoCAD SHX Text
PTZ
AutoCAD SHX Text
FAC
AutoCAD SHX Text
FACP
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text ALARM, FIRE; LETTERS INDICATE AS FOLLOWS: BATT = BATTERIES CHR = CHARGER FAR = BATTERIES CHR = CHARGER FAR = CHR = CHARGER FAR = FAR = RECORDER
AutoCAD SHX Text
BATT
AutoCAD SHX Text
ALARM, FIRE, TERMINAL CABINET.TERMINAL CABINET.
AutoCAD SHX Text
FATC
AutoCAD SHX Text
ALARM, FIRE, POST INDICATOR VALVE.POST INDICATOR VALVE.
AutoCAD SHX Text
PIV
AutoCAD SHX Text M
AutoCAD SHX Text
FS
AutoCAD SHX Text
ALARM, TRANSPONDER OR TRANSMITTER
AutoCAD SHX Text
FTR
AutoCAD SHX Text
ALARM, VOICE COMMUNICATION PANEL
AutoCAD SHX Text
CP
AutoCAD SHX Text
AUTOMATIC TRANSFER SWITCH ON CONCRETE PAD
AutoCAD SHX Text T
AutoCAD SHX Text
TRANSFORMER ON CONCRETE PAD
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
DATA LINE, MINIMUM 1" CONDUIT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VFD
AutoCAD SHX Text
HP
AutoCAD SHX Text
HP
AutoCAD SHX Text
ATS
AutoCAD SHX Text
SUPERVISORY SWITCH
AutoCAD SHX Text
SS
AutoCAD SHX Text
ALARM, FIRE, ADDRESSABLE INTERFACE MODULE
AutoCAD SHX Text
AIM
AutoCAD SHX Text
ALARM, FIRE, REMOTE INDICATOR AND TEXT SWITCH
AutoCAD SHX Text
RI
AutoCAD SHX Text
EMERGENCY CALL FOR AID (BLUE LIGHT) STATION.
AutoCAD SHX Text
CR
AutoCAD SHX Text
SECURITY SYSTEM, CARD READER
AutoCAD SHX Text
XX-YY
AutoCAD SHX Text
CEILING MOUNTED OCCUPANCY SENSOR: CONNECT AFTER WALL SWITCH IF PRESENT
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text
FO
AutoCAD SHX Text
CCTV
AutoCAD SHX Text
CATV
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
WH
AutoCAD SHX Text W
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LIGHT FIXTURE, CEILING SURFACE/RECESSED, EMERGENCY; LETTER INDICATES TYPE
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
1. VERIFY EXISTING CONDITIONS ON THE JOB SITE BEFORE VERIFY EXISTING CONDITIONS ON THE JOB SITE BEFORE BEGINNING ANY WORK. COORDINATE DEMOLITION AND NEW CONSTRUCTION WITH THE OWNER PRIOR TO COMMENCEMENT OF WORK. COMMENCEMENT OF WORK SIGNIFIES ACCEPTANCE OF CONDITIONS. 2. EXECUTE DEMOLITION IN A SAFE MANNER. EGRESS, EXITS EXECUTE DEMOLITION IN A SAFE MANNER. EGRESS, EXITS AND FIRE PROTECTION REQUIREMENTS SHALL BE MAINTAINED. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION NECESSARY TO COMPLETE THE WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REMOVAL AND PROPER DISPOSAL, INCLUDING COSTS FOR HAULING AND DUMPING OF ALL MATERIAL DEMOLISHED. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, FIRESTOPPING AND SEALING ALL NEW AND EXISTING WALL, FLOOR OR CEILING PENETRATIONS TO MATCH THE EXISTING CONDITION INCLUDING FIRE RATING. 4. ACCESS TO AND CLEARANCES AROUND ELECTRICAL ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT SHALL CONFORM TO N.E.C. ARTICLES 110. CONSULT ENGINEER WHERE SPACE APPEARS INADEQUATE DUE TO ARCHITECTURAL CHANGES, EQUIPMENT LAYOUT CHANGES, OR FIELD CONDITIONS. DO NOT COVER, OBSCURE OR BLOCK ACCESS TO EQUIPMENT DATA PLATES, ACCESS PANELS OR MAINTENANCE AREAS WITH THE ELECTRICAL WORK. 5. THESE DRAWINGS SHOW EQUIPMENT LOCATIONS ONLY. WIRING THESE DRAWINGS SHOW EQUIPMENT LOCATIONS ONLY. WIRING SHOWN IS SCHEMATIC IN NATURE. REFER TO RISERS AND DETAILS FOR ALL REQUIRED POWER AND CONTROL WIRING. COORDINATE CONDUIT ROUTE IN FIELD WITH OTHER TRADES, EQUIPMENT AND OWNER. VERIFY ALL MOUNTING HEIGHTS WITH OWNER AND ENGINEER PRIOR TO INSTALLATION. 6. UNLESS OTHERWISE NOTED, EXISTING EQUIPMENT SUCH AS UNLESS OTHERWISE NOTED, EXISTING EQUIPMENT SUCH AS LIGHTING FIXTURES, WIRING DEVICES, CONDUITS, PANELS, SWITCHBOARDS, ETC. SHOWN ON PLANS TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY. 7. UNLESS OTHERWISE NOTED, DISCONNECT AND REMOVE ALL UNLESS OTHERWISE NOTED, DISCONNECT AND REMOVE ALL WIRING TO IT'S OVER CURRENT PROTECTIVE DEVICE OR THE FIRST ACTIVE DEVICE OUTSIDE THE AREA OF WORK. REMOVE ALL RELATED CONDUIT AND WIRING WITHIN THE AREA OF WORK. 8. UNLESS OTHERWISE NOTED, CONDUITS THAT EXTEND BEYOND UNLESS OTHERWISE NOTED, CONDUITS THAT EXTEND BEYOND THE AREA OF WORK SHALL BE CUT AND CAPPED AT AREA OF WORK PERIMETER. 9. REMOVE ALL ACCESSIBLE INACTIVE OR ABANDONED WIRING OR REMOVE ALL ACCESSIBLE INACTIVE OR ABANDONED WIRING OR CONDUIT OF ALL TYPES WITHIN THE AREA OF WORK. WHEN DIRECTED TO ABANDON IN PLACE EXISTING WIRING, TERMINATE SUCH WIRING IN A JUNCTION BOX AND LABEL IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE. 10. MAINTAIN ALL EXISTING ACTIVE CONDUITS AND WIRING WITHIN MAINTAIN ALL EXISTING ACTIVE CONDUITS AND WIRING WITHIN THE AREA OF WORK THAT SERVES ADJOINING AREAS OR AS NOTED. THE CONTRACTOR IS RESPONSIBLE REPAIRING AND RESTORING ANY SUCH SERVICES INTERRUPTED BY HIS WORK. 11. AS PART OF THE INSTALLATION OF NEW EQUIPMENT, THE AS PART OF THE INSTALLATION OF NEW EQUIPMENT, THE CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND RELOCATION OF MISCELLANEOUS EXISTING DEVICES AND CONDUIT THAT INTERFERE WITH THE NEW INSTALLATION. THIS INCLUDES DEVICES SUCH AS LIGHT FIXTURES, OUTLETS, JUNCTION BOXES AND CONDUIT. 12. CONTRACTOR SHALL PROVIDE PLANS TO OWNER FOR ALL CONTRACTOR SHALL PROVIDE PLANS TO OWNER FOR ALL SHUTDOWNS AND INTERRUPTIONS WITH A MINIMUM OF 2 WEEKS NOTICE UNLESS NOTED OTHERWISE IN THE CONTRACT DOCUMENTS.
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text H4
AutoCAD SHX Text
DETAIL NUMBER
AutoCAD SHX Text
DRAWING NUMBER WHERE DRAWN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FINAL SUBMISSION
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
AI ENGINEERS INC.
919 MIDDLE STREET
MIDDLETOWN, CT 06457
(860) 635-7740
GEOTECHNICAL ENGINEERING
GEI Consultants, Inc.
44 Winding Brook Drive Glastonbury, CT 06033 860-368-5300
VAMC PROVIDENCE, RI
FCA PAVEMENT REPAIRS
AIR FORCE DRIVE
PROVIDENCE, R.I.
650-07-102
Project Director
2/21/2018 MR/RG MLRevisions: Date:
35% DESIGN 10/13/17
60% DESIGN 12/12/17
100% DESIGN 02/01/18
EXISTING SITE LIGHTING
AND REMOVALS
E1.00
NOTES
AutoCAD SHX Text
GRAVEL AREA
AutoCAD SHX Text
GRAVEL AREA
AutoCAD SHX Text
GRAVEL PARKING AREA
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
BENCHMARK CHISEL SQ 62.46
AutoCAD SHX Text
BENCHMARK NAIL SET 61.78
AutoCAD SHX Text
BENCHMARK XCUT IN LP 85.57'
AutoCAD SHX Text
BENCHMARK X CUT ON N'LY BOLT 29.03'
AutoCAD SHX Text
ELEC HH
AutoCAD SHX Text
ELEC HH
AutoCAD SHX Text
METAL GDR
AutoCAD SHX Text
METAL GDR
AutoCAD SHX Text
METAL GDR
AutoCAD SHX Text
METAL GDR
AutoCAD SHX Text
METAL GDR
AutoCAD SHX Text
METAL GDR
AutoCAD SHX Text
WOODEN GDR
AutoCAD SHX Text
WOODEN GDR
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CURB
AutoCAD SHX Text
CONC
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CURB
AutoCAD SHX Text
CONC
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC
AutoCAD SHX Text
CURB
AutoCAD SHX Text
ELECTRIC MH RIM=80.51'
AutoCAD SHX Text
ELECTRIC MH RIM=80.92'
AutoCAD SHX Text
ELECTRIC MH RIM=82.54'
AutoCAD SHX Text
ELECTRIC MH RIM=81.25'
AutoCAD SHX Text
ELECTRIC MH RIM=81.92'
AutoCAD SHX Text
ELECTRIC MH RIM=81.62'
AutoCAD SHX Text
ELECTRIC MH RIM=70.67'
AutoCAD SHX Text
TELEPHONE MH RIM=73.32'
AutoCAD SHX Text
ELECTRIC MH RIM=77.72'
AutoCAD SHX Text
ELECTRIC MH RIM=79.26'
AutoCAD SHX Text
ELECTRIC MH RIM=78.79'
AutoCAD SHX Text
ELECTRIC MH RIM=76.10'
AutoCAD SHX Text
ELECTRIC MH RIM = 74.37
AutoCAD SHX Text
ELECTRIC MH RIM=76.08
AutoCAD SHX Text
SAN MH RIM=80.59'
AutoCAD SHX Text SAN MH RIM=83.47' INV=79.07'(12" RCP NE) INV=74.43'(8" CLAY SE) INV=61.07'(12" CLAY S) INV=61.00(12" CLAY N)
AutoCAD SHX Text
ELECTRIC MH RIM=83.18'
AutoCAD SHX Text
WG
AutoCAD SHX Text
HYD
AutoCAD SHX Text
ELECTRIC MH RIM=83.61'
AutoCAD SHX Text
TELE MH RIM=83.45'
AutoCAD SHX Text
EMERGENCY CALL BOX
AutoCAD SHX Text
ELECTRIC MH RIM=80.49'
AutoCAD SHX Text
HYD
AutoCAD SHX Text
WG
AutoCAD SHX Text
WG
AutoCAD SHX Text
CONC PAD
AutoCAD SHX Text
TEMP CLF
AutoCAD SHX Text
TEMP CLF
AutoCAD SHX Text
GG
AutoCAD SHX Text
CONC PAD
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
ELECTRIC BOX ON CONC PAD
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
GARDEN AREA
AutoCAD SHX Text
GRAVEL AREA
AutoCAD SHX Text
GDR
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text D
AutoCAD SHX Text
ELEC HH
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
CONC PAD
AutoCAD SHX Text
ELECTRIC HH
AutoCAD SHX Text
ELECTRIC HH
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
DRAIN MH RIM=83.13'
AutoCAD SHX Text
TYPE CL CB RIM=55.54' INV=50.23'(12' RCP NW)
AutoCAD SHX Text
AIR FORCE DRIVE
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
POLICE BLDG T18
AutoCAD SHX Text
EDGE OF PAVE
AutoCAD SHX Text S
AutoCAD SHX Text
3 BOLLARDS
AutoCAD SHX Text
GRASS AREA
AutoCAD SHX Text
EDGE OF PAVE
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text E
AutoCAD SHX Text
ELECTRIC MH RIM=79.09'
AutoCAD SHX Text
EDGE OF PAVE
AutoCAD SHX Text
UNDER WALL & GARDEN
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
HEATING & COOLING AREA
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
H. RAMP
AutoCAD SHX Text
HEATING & COOLING AREA
AutoCAD SHX Text
BLDG #9
AutoCAD SHX Text
BLDG #10
AutoCAD SHX Text
BLDG #11
AutoCAD SHX Text
WOODED AREA
AutoCAD SHX Text
WOODED AREA
AutoCAD SHX Text
WOOD FENCE
AutoCAD SHX Text
WOODED AREA
AutoCAD SHX Text
WOODED AREA
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
CONC RW
AutoCAD SHX Text
WOODED AREA
AutoCAD SHX Text
EDGE OF PAVEMENT
AutoCAD SHX Text
EDGE OF PAVEMENT
AutoCAD SHX Text
LANDSCAPE AREA
AutoCAD SHX Text
BLDG T36
AutoCAD SHX Text
BLDG T35
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text
CP30 DH N:272624.61 E:346636.12
AutoCAD SHX Text
OVERFLOW PARKING LOT 10
AutoCAD SHX Text
BLDG #35
AutoCAD SHX Text
GRAVEL AREA
AutoCAD SHX Text
SHED
AutoCAD SHX Text
SHED
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text S
AutoCAD SHX Text
SAN MH (N/F)
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text S
AutoCAD SHX Text
UNDER CONSTRUCTION
AutoCAD SHX Text
BOLLARD TYP.
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text
SALT SHED OVERHANG
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
SYL
AutoCAD SHX Text
SYL
AutoCAD SHX Text
BIT
AutoCAD SHX Text
BIT
AutoCAD SHX Text
BIT
AutoCAD SHX Text
BIT
AutoCAD SHX Text
BOLLARDS
AutoCAD SHX Text W
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPS
AutoCAD SHX Text B-1
AutoCAD SHX Text B-2
AutoCAD SHX Text B-11
AutoCAD SHX Text B-10
AutoCAD SHX Text B-12
AutoCAD SHX Text B-13
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
ER
AutoCAD SHX Text
RE
AutoCAD SHX Text
RE
AutoCAD SHX Text
RE
AutoCAD SHX Text
RE
AutoCAD SHX Text
RE
AutoCAD SHX Text
RE
AutoCAD SHX Text
RE
AutoCAD SHX Text
RE
AutoCAD SHX Text
RE
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
1. VERIFY EXISTING CONDITIONS ON THE JOB SITE BEFORE BEGINNING ANY VERIFY EXISTING CONDITIONS ON THE JOB SITE BEFORE BEGINNING ANY WORK. COORDINATE DEMOLITION AND NEW CONSTRUCTION WITH THE OWNER PRIOR TO COMMENCEMENT OF WORK. COMMENCEMENT OF WORK SIGNIFIES ACCEPTANCE OF CONDITIONS. 2. EXECUTE DEMOLITION IN A SAFE MANNER. EGRESS, EXITS AND FIRE EXECUTE DEMOLITION IN A SAFE MANNER. EGRESS, EXITS AND FIRE PROTECTION REQUIREMENTS SHALL BE MAINTAINED. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION NECESSARY TO COMPLETE THE WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REMOVAL AND PROPER DISPOSAL, INCLUDING COSTS FOR HAULING AND DUMPING OF ALL MATERIAL DEMOLISHED. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, FIRESTOPPING CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, FIRESTOPPING AND SEALING ALL NEW AND EXISTING WALL, FLOOR OR CEILING PENETRATIONS TO MATCH THE EXISTING CONDITION INCLUDING FIRE RATING. 4. ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT SHALL ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT SHALL CONFORM TO N.E.C. ARTICLES 110. CONSULT ENGINEER WHERE SPACE APPEARS INADEQUATE. 5. EXISTING SITE LIGHTING TO REMAIN. MAINTAIN EXISTING CIRCUITING AND EXISTING SITE LIGHTING TO REMAIN. MAINTAIN EXISTING CIRCUITING AND CONTROLS. PROVIDE TEMPORARY WIRING AND CONDUIT AS REQUIRED TO MAINTAIN FIXTURE OPERATION DURING CONSTRUCTION. 6. ALL SITE LIGHTING FIXTURES AND POLES TO BE REMOVED SHALL BE ALL SITE LIGHTING FIXTURES AND POLES TO BE REMOVED SHALL BE DISASSEMBLED AND PROTECTED AS IF BEING REUSED. HANDOVER SITE LIGHTING FIXTURES AND POLES TO OWNER. 7. EXISTING SITE LIGHTING IS POWERED AND CONTROLLED BY PANEL EXISTING SITE LIGHTING IS POWERED AND CONTROLLED BY PANEL "SL-35" LOCATED AT THE BASEMENT LEVEL OF BLDG 35. IDENTIFY EXISTING CIRCUITS IMPACTED BY REMOVALS AND RETAIN FOR REUSE. DETERMINE CIRCUIT LOAD PRIOR TO SITE LIGHTING DEMOLITION AND AFTER DEMOLITION. PROVIDE LOADS TO VA AND A/E FOR REVIEWS. MAINTAIN PANEL OPERATION AND EXISTING CIRCUITS TO REMAIN THROUGHOUT CONSTRUCTION. 8. EXISTING EMERGENCY CALL BOX AND CONNECTED TO CAMPUS EXISTING EMERGENCY CALL BOX AND CONNECTED TO CAMPUS COMMUNICATIONS BY CAT 6 CABLE TO THE COMMUNICATION ROOM LOCATED AT THE BASEMENT LEVEL OF BLDG 35. 9. EXISTING 2" SITE LIGHTING AND COMMUNICATIONS CONDUITS TO BLDG EXISTING 2" SITE LIGHTING AND COMMUNICATIONS CONDUITS TO BLDG 35 TO BE REMOVED BACK TO EXISTING HANDHOLES. 10. REPLACE EXISTING SITE LIGHTING AND COMMUNICATIONS HANDHOLES AT REPLACE EXISTING SITE LIGHTING AND COMMUNICATIONS HANDHOLES AT THIS LOCATION. MAINTAIN EXISTING SITE LIGHTING CIRCUITS AT THIS LOCATION. 11. REMOVE EXISTING SITE LIGHTING FIXTURES, POLES, POLE BASES AND REMOVE EXISTING SITE LIGHTING FIXTURES, POLES, POLE BASES AND RELATED WIRING. 12. REMOVE EXISTING LIGHT FIXTURES AND POLE AT THIS LOCATION. REMOVE EXISTING LIGHT FIXTURES AND POLE AT THIS LOCATION. MAINTAIN EXISTING CIRCUIT FOR REUSE. 13. REMOVE EXISTING SITE LIGHTING FIXTURE, POLE, POLE BASES AND REMOVE EXISTING SITE LIGHTING FIXTURE, POLE, POLE BASES AND RELATED WIRING. COORDINATE WITH EXISTING MECHANICAL EQUIPMENT AND BURIED PIPING IN THIS AREA. ADVISE VA OF ANY DISCOVERED CONDITIONS PRIOR TO REMOVAL. 14. EXISTING SECURITY CAMERAS MOUNTED ON LIGHT POLE TO BE EXISTING SECURITY CAMERAS MOUNTED ON LIGHT POLE TO BE REMOVED AND RESTORED BY CONTRACTOR FOR REUSE. 15. EXISTING EMERGENCY CALL BOX TO BE REMOVED AND STORED BY EXISTING EMERGENCY CALL BOX TO BE REMOVED AND STORED BY CONTRACTOR FOR REUSE. REFER TO NOTE #8. 16. REMOVE EXISTING COMMUNICATIONS CONDUITS, WIRING AND HANDHOLES REMOVE EXISTING COMMUNICATIONS CONDUITS, WIRING AND HANDHOLES BACK TO POINT SHOWN. REMOVE FIBER OPTIC CABLES BACK TO COMMUNICATIONS ROOM IN BLDG 35.
AutoCAD SHX Text
REFER TO NOTE #11. (TYP.)
AutoCAD SHX Text
REFER TO NOTE #11. (TYP.)
AutoCAD SHX Text
REFER TO NOTE #5. (TYP.)
AutoCAD SHX Text
REFER TO NOTE #5. (TYP.)
AutoCAD SHX Text REMOVE EXISTING SITE LIGHTING FIXTURE, POLE BASE AND ALL RELOCATED WIRING. MAINTAIN CIRCUITS TO REMAINING FIXTURES ON AIR FORCE DRIVE.
AutoCAD SHX Text EXISTING PATH LIGHTING NOT SHOWN. MAINTAIN EXISTING LIGHTING AND RELATED WIRING, CONDUIT AND CONTROLS DURING CONSTRUCTION.
AutoCAD SHX Text EXISTING SITE LIGHTING AND COMMUNICATIONS (CAMERA AND EMERGENCY CALL) HANDHOLES TO REMAIN. MAINTAIN EXISTING SITE LIGHTING CIRCUITS FOR REUSE.
AutoCAD SHX Text EXISTING 2" SITE LIGHTING AND COMMUNICATIONS CONDUITS BACK TO BLDG #35. MAINTAIN FOR REUSE.
AutoCAD SHX Text
COMMUNICATIONS ROOM IN BASEMENT
AutoCAD SHX Text
BLDG #35
AutoCAD SHX Text
SITE LTG PANELS IN BASEMENT. REFER TO NOTE #7.
AutoCAD SHX Text
REFER TO NOTE #10.
AutoCAD SHX Text
REFER TO NOTE #13.
AutoCAD SHX Text
REFER TO NOTE #11. (TYP.)
AutoCAD SHX Text
EXISTING 2" SITE LIGHTING CONDUIT BACK TO BLDG #35 TO REMAIN.
AutoCAD SHX Text
REFER TO NOTE #11. (TYP.)
AutoCAD SHX Text
REMOVE CONDUIT TO 5' FROM POLE BASE.
AutoCAD SHX Text
RE
AutoCAD SHX Text
RE
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
REFER TO NOTE #5. (TYP.)
AutoCAD SHX Text
REFER TO NOTE #15.
AutoCAD SHX Text
REFER TO NOTE #11. (TYP.)
AutoCAD SHX Text
REFER TO NOTE #9. (TYP.)
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRIC MANHOLE; RIM=42.50 REFER TO NOTE #10.
AutoCAD SHX Text
REFER TO NOTE #8 & NOTE #14.
AutoCAD SHX Text
EXISTING SECURITY CAMERA TO REMAIN.
AutoCAD SHX Text
BUILDING 35 BASEMENT PLAN SCALE: 1" = 30 FT.
AutoCAD SHX Text
REFER TO NOTE #8 & NOTE #14.
AutoCAD SHX Text
REFER TO NOTE #1
AutoCAD SHX Text
REFER TO NOTE #8 & NOTE #14.
AutoCAD SHX Text
SCALE: 1" = 30 FT.
AutoCAD SHX Text
EXISTING SITE LIGHTING
AutoCAD SHX Text
REFER TO NOTE #5.
AutoCAD SHX Text
BLDG #35
AutoCAD SHX Text
SCALE: 1" = 30 FT.
AutoCAD SHX Text
PARTIAL PLAN BUILDING 35 BASEMENT
AutoCAD SHX Text
OUTLINE OF BUILDING BASEMENT LEVEL. REFER TO PARTIAL PLAN ON THIS DRAWING.
AutoCAD SHX Text
ELECTRICAL ROOM
AutoCAD SHX Text
COMMUNICATIONS ROOM
AutoCAD SHX Text
REFER TO NOTE #16.
AutoCAD SHX Text
REFER TO NOTE #16 (TYP.)
REFER TO NOTE #16.
S T
O P
S L O
W
S T
O P
STO
P
H
H
H
H
H
C
C
C A
C
A
H
H
C
NEW SITE LIGHTING
E-101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
FINAL SUBMISSION
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
AI ENGINEERS INC.
919 MIDDLE STREET
MIDDLETOWN, CT 06457
(860) 635-7740
GEOTECHNICAL ENGINEERING
GEI Consultants, Inc.
44 Winding Brook Drive Glastonbury, CT 06033 860-368-5300
VAMC PROVIDENCE, RI
FCA PAVEMENT REPAIRS
AIR FORCE DRIVE
PROVIDENCE, R.I.
650-07-102
Project Director
2/21/2018 MR/RG MLRevisions: Date:
35% DESIGN 10/13/17
60% DESIGN 12/12/17
100% DESIGN 02/01/18
NOTES
AutoCAD SHX Text
GRAVEL AREA
AutoCAD SHX Text
GRAVEL AREA
AutoCAD SHX Text
GRAVEL PARKING AREA
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
ELEC HH
AutoCAD SHX Text
ELEC HH
AutoCAD SHX Text
METAL GDR
AutoCAD SHX Text
WOODEN GDR
AutoCAD SHX Text
WOODEN GDR
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CURB
AutoCAD SHX Text
CONC
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CURB
AutoCAD SHX Text
CONC
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
CLF
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
CONC CURB
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
CONC
AutoCAD SHX Text
CURB
AutoCAD SHX Text
ELECTRIC MH RIM=80.51'
AutoCAD SHX Text
ELECTRIC MH RIM=80.92'
AutoCAD SHX Text
ELECTRIC MH RIM=82.54'
AutoCAD SHX Text
ELECTRIC MH RIM=81.25'
AutoCAD SHX Text
ELECTRIC MH RIM=83.06'
AutoCAD SHX Text
ELECTRIC MH RIM=81.92'
AutoCAD SHX Text
ELECTRIC MH RIM=81.62'
AutoCAD SHX Text
ELECTRIC MH RIM=70.67'
AutoCAD SHX Text
TELEPHONE MH RIM=73.32'
AutoCAD SHX Text
ELECTRIC MH RIM=77.72'
AutoCAD SHX Text
ELECTRIC MH RIM=79.26'
AutoCAD SHX Text
ELECTRIC MH RIM=78.79'
AutoCAD SHX Text
ELECTRIC MH RIM=76.10'
AutoCAD SHX Text
ELECTRIC MH RIM = 74.37
AutoCAD SHX Text
ELECTRIC MH RIM=76.08
AutoCAD SHX Text
ELECTRIC MH RIM=83.18'
AutoCAD SHX Text
WG
AutoCAD SHX Text
ELECTRIC MH RIM=83.61'
AutoCAD SHX Text
TELE MH RIM=83.45'
AutoCAD SHX Text
EMERGENCY CALL BOX
AutoCAD SHX Text
ELECTRIC MH RIM=80.49'
AutoCAD SHX Text
HYD
AutoCAD SHX Text
CONC PAD
AutoCAD SHX Text
TEMP CLF
AutoCAD SHX Text
TEMP CLF
AutoCAD SHX Text
GG
AutoCAD SHX Text
CONC PAD
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
ELECTRIC BOX ON CONC PAD
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
GARDEN AREA
AutoCAD SHX Text
GRAVEL AREA
AutoCAD SHX Text
GDR
AutoCAD SHX Text
GDR
AutoCAD SHX Text
GDR
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
CLF
AutoCAD SHX Text
ELEC HH
AutoCAD SHX Text
RET WALL
AutoCAD SHX Text
CONC PAD
AutoCAD SHX Text
ELECTRIC HH
AutoCAD SHX Text
ELECTRIC HH
AutoCAD SHX Text
GRAN CURB
AutoCAD SHX Text
AIR FORCE DRIVE
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
POLICE BLDG T18
AutoCAD SHX Text
EDGE OF PAVE
AutoCAD SHX Text S
AutoCAD SHX Text
3 BOLLARDS
AutoCAD SHX Text
GRASS AREA
AutoCAD SHX Text
EDGE OF PAVE
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text E
AutoCAD SHX Text
ELECTRIC MH RIM=79.09'
AutoCAD SHX Text
EDGE OF PAVE
AutoCAD SHX Text
EDGE OF PAVE
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
HEATING & COOLING AREA
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
HEATING & COOLING AREA
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
BLDG #9
AutoCAD SHX Text
BLDG #10
AutoCAD SHX Text
BLDG #11
AutoCAD SHX Text
WOODED AREA
AutoCAD SHX Text
WOODED AREA
AutoCAD SHX Text
WOOD FENCE
AutoCAD SHX Text
WOODED AREA
AutoCAD SHX Text
WOODED AREA
AutoCAD SHX Text
CONC WALK
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
CONC RW
AutoCAD SHX Text
WOODED AREA
AutoCAD SHX Text
LANDSCAPE AREA
AutoCAD SHX Text
BLDG T36
AutoCAD SHX Text
BLDG T35
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
WOODED AREA
AutoCAD SHX Text
FLOW DRAINAGE SWALE
AutoCAD SHX Text
BLDG #35
AutoCAD SHX Text
GRAVEL AREA FOR PLOWS
AutoCAD SHX Text
GRAVEL AREA
AutoCAD SHX Text
SHED
AutoCAD SHX Text
SHED
AutoCAD SHX Text S
AutoCAD SHX Text
BOILER PLANT
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
H.RAMP
AutoCAD SHX Text
ARMED FORCES BLVD
AutoCAD SHX Text
UNDER CONSTRUCTION
AutoCAD SHX Text
BOLLARD TYP.
AutoCAD SHX Text
GAS METER
AutoCAD SHX Text
SALT SHED OVERHANG
AutoCAD SHX Text
SYL
AutoCAD SHX Text
SYL
AutoCAD SHX Text
SYL
AutoCAD SHX Text
SYL
AutoCAD SHX Text
BOLLARDS
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
1. VERIFY EXISTING CONDITIONS ON THE JOB SITE BEFORE BEGINNING ANY VERIFY EXISTING CONDITIONS ON THE JOB SITE BEFORE BEGINNING ANY WORK. COORDINATE DEMOLITION AND NEW CONSTRUCTION WITH THE OWNER PRIOR TO COMMENCEMENT OF WORK. COMMENCEMENT OF WORK SIGNIFIES ACCEPTANCE OF CONDITIONS. 2. EXECUTE DEMOLITION IN A SAFE MANNER. EGRESS, EXITS AND FIRE EXECUTE DEMOLITION IN A SAFE MANNER. EGRESS, EXITS AND FIRE PROTECTION REQUIREMENTS SHALL BE MAINTAINED. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION NECESSARY TO COMPLETE THE WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REMOVAL AND PROPER DISPOSAL, INCLUDING COSTS FOR HAULING AND DUMPING OF ALL MATERIAL DEMOLISHED. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, FIRESTOPPING CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, FIRESTOPPING AND SEALING ALL NEW AND EXISTING WALL, FLOOR OR CEILING PENETRATIONS TO MATCH THE EXISTING CONDITION INCLUDING FIRE RATING. 4. ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT SHALL ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT SHALL CONFORM TO N.E.C. ARTICLES 110. CONSULT ENGINEER WHERE SPACE APPEARS INADEQUATE DUE. 5. EXISTING SITE LIGHTING PANEL "SL-35" LOCATED IN BLDG 35 EXISTING SITE LIGHTING PANEL "SL-35" LOCATED IN BLDG 35 BASEMENT ELECTRICAL ROOM. 6. EXISTING IT ROOM IN BLDG 35 BASEMENT. RELOCATED EMERGENCY EXISTING IT ROOM IN BLDG 35 BASEMENT. RELOCATED EMERGENCY CALL BOX CONNECTS TO THIS ROOM WITH NEW CAT 6 DATA CABLE. TERMINATE AS DIRECTED BY THE VA. 7. NEW SITE LIGHTING AND COMMUNICATION HANDHOLES. CONNECT TO NEW SITE LIGHTING AND COMMUNICATION HANDHOLES. CONNECT TO EXISTING 2" SITE LIGHTING AND COMMUNICATION CONDUITS. EXTEND NEW CONDUITS AND WIRING SHOWN. 8. NEW SITE LIGHTING FIXTURE AND POLE LETTER INDICATE TYPE: REFER NEW SITE LIGHTING FIXTURE AND POLE LETTER INDICATE TYPE: REFER TO LIGHT FIXTURE SCHEDULE. NUMBER INDICATES CIRCUIT IN PANEL "SL-35". 9. NEW LOCATION FOR EXISTING EMERGENCY CALL FOR AID BOX. NEW LOCATION FOR EXISTING EMERGENCY CALL FOR AID BOX. 10. REINSTALL SINGLE SECURITY CAMERA AND DATA ENCLOSURE ON THIS REINSTALL SINGLE SECURITY CAMERA AND DATA ENCLOSURE ON THIS POLE. MOUNTING HEIGHT AND CAMERA ORIENTATIONS DIRECTED BY VA. 11. REINSTALL TWO SECURITY CAMERAS AND ONE DATA ENCLOSURE ON REINSTALL TWO SECURITY CAMERAS AND ONE DATA ENCLOSURE ON THIS POLE. MOUNTING HEIGHT AND CAMERA ORIENTATIONS DIRECTED BY VA. 12. NEW EMERGENCY CALL BOX. CONNECT TO BLDG 35 FOR POWER AND NEW EMERGENCY CALL BOX. CONNECT TO BLDG 35 FOR POWER AND COMMUNICATIONS. 13. CONTRACTOR SHALL VERIFY AND DOCUMENT CALLBOX AND SECURITY CONTRACTOR SHALL VERIFY AND DOCUMENT CALLBOX AND SECURITY CAMERA OPERATION PRIOR TO ANY WORK. CONTRACTOR SHALL TEST ALL REINSTALLED SECURITY CAMERAS AS WELL AS NEW AND REINSTALLED CALL BOXES TO DEMONSTRATE THAT ORIGINAL PERFORMANCE HAS BEEN MAINTAINED. 14. NEW LIGHTING FIXTURES ARE LABELED AS FIXTURE TYPE WITH CIRCUIT NEW LIGHTING FIXTURES ARE LABELED AS FIXTURE TYPE WITH CIRCUIT NUMBER. THAT IS A#7 WHICH MEANS FIXTURE TYPE A ON CIRCUIT #7. 15. CIRCUIT NUMBERS ARE ARBITRARY LABELS TO SHOW FIXTURE GROUPS. CIRCUIT NUMBERS ARE ARBITRARY LABELS TO SHOW FIXTURE GROUPS. REUSE EXISTING CIRCUITS IN PANEL "SL-35" AND NUMBER APPROXIMATELY ON RECORD DRAWINGS.
AutoCAD SHX Text
REFER TO NOTE #5.
AutoCAD SHX Text
EXISTING SITE LIGHTING AND COMMUNICATIONS HANDHOLES.
AutoCAD SHX Text
BLDG #35
AutoCAD SHX Text
EXISTING 2" SITE LIGHTING AND COMMUNICATIONS CONDUITS BACK TO BLDG 35.
AutoCAD SHX Text
REFER TO NOTE #8 (TYP.)
AutoCAD SHX Text A#7
AutoCAD SHX Text A#7
AutoCAD SHX Text A#9
AutoCAD SHX Text A#11
AutoCAD SHX Text A#11
AutoCAD SHX Text A#9
AutoCAD SHX Text A#8
AutoCAD SHX Text A#10
AutoCAD SHX Text A#1
AutoCAD SHX Text C#12
AutoCAD SHX Text A#3
AutoCAD SHX Text A#3
AutoCAD SHX Text A#3
AutoCAD SHX Text B#5
AutoCAD SHX Text
REFER TO NOTE #8 (TYP.)
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
ER
AutoCAD SHX Text
EMERGENCY CALL BOX REFER TO NOTE #9
AutoCAD SHX Text
REFER TO NOTE #8 (TYP.)
AutoCAD SHX Text
EXISTING 2" SITE LIGHTING CONDUITS AND CIRCUITS BACK TO BLDG 35.
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CONNECT EXISTING SITE LIGHTING CIRCUIT.
AutoCAD SHX Text
SECURITY CAMERA REFER TO NOTE #10.
AutoCAD SHX Text
REFER TO NOTE #7.
AutoCAD SHX Text
2"C-6#6+1#8G +2#6 COMM POWER
AutoCAD SHX Text
NEW EMERGENCY CALL BOX REFER TO NOTE #12.
AutoCAD SHX Text
2"C-1 CAT 6 CABLE.
AutoCAD SHX Text
REFER TO NOTE #7.
AutoCAD SHX Text 2"C-3#6+1#8G
AutoCAD SHX Text 2"C-2#6+1#8G
AutoCAD SHX Text
2"C-3#6+2#6COMM POWER+1#8G.
AutoCAD SHX Text
NEW SITE LIGHTING SCALE 1" = 30 FT.
AutoCAD SHX Text
SCALE: 1" = 30 FT.
AutoCAD SHX Text
PARTIAL PLAN BUILDING 35 BASEMENT
AutoCAD SHX Text
SECURITY CAMERAS. REFER TO NOTE #11.
AutoCAD SHX Text
SECURITY CAMERAS. REFER TO NOTE #11.
AutoCAD SHX Text
REFER TO NOTE #6.
AutoCAD SHX Text
OUTLINE OF BUILDING BASEMENT LEVEL. REFER TO PARTIAL PLAN ON THIS DRAWING.
AutoCAD SHX Text
ELECTRICAL ROOM
COMMUNICATIONS ROOM
S T
O P
S L O
W
S T
O P
STO
P
0.2
0.2
0.2
0.2
0.3
0.3
0.2
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.5
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.5
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.9
0.8
0.8
0.8
0.8
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.8
0.9
0.9
0.9
0.9
0.9
0.8
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.0
0.9
0.9
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.0
1.0
1.0
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.1
1.2
1.2
1.2
1.1
1.1
1.1
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.0
1.0
1.1
1.2
1.3
1.3
1.2
1.2
1.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.1
1.1
1.2
1.2
1.3
1.3
1.2
1.2
1.2
1.2
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.2
1.2
1.2
1.3
1.4
1.3
1.3
1.3
1.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.1
1.1
1.2
1.2
1.3
1.3
1.4
1.5
1.4
1.4
1.4
1.4
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.3
1.4
1.4
1.4
1.5
1.5
1.5
1.5
1.6
1.5
1.5
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.6
1.6
1.6
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.4
1.5
1.6
1.6
1.7
1.8
1.8
1.8
1.8
1.9
1.9
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.5
1.6
1.7
1.7
1.9
2.0
2.0
2.0
2.1
2.1
2.1
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.9
0.9
0.9
0.9
0.9
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.1
2.2
2.2
2.3
2.2
2.2
2.2
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.8
0.8
0.8
0.7
0.7
0.8
0.8
0.8
0.8
0…
This is the start of the file's text. The full file is on GovTribe.