36C24119R0031_1.docx

DOCX document 14 KB Posted

Attached to
PVC Replacement 523A4-19-002 Federal contract opportunity
Solicitation number
36C24119R0031
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1

About this file

36C24119R0031 36C24119R0031_1.docx

View the file

Other files for this federal contract opportunity

Other files attached to PVC Replacement 523A4-19-002, newest first.
File Type Posted
-16028.docx DOCX document
36C24119R0031_0003.docx DOCX document
36C24119R0031_0002.docx DOCX document
36C24119R0031_0001.docx DOCX document
36C24119R0031.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FedBizOpps Presolicitation Notice

CLASSIFICATION CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

RESPONSE DATE (MM-DD-YYYY)

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

* = Required Field FedBizOpps Presolicitation Notice Rev. March 2010 J PVC Replacement on Cooling Tower 02301 36C24119R0031 12-28-2018 N 238220 Department of Veterans Affairs VA Boston Healthcare System Contracting Officer (90C) 940 Belmont Street Brockton MA 02301 Gail Grundy Department of Veterans Affairs VAMC West Roxbury 1400 VFW Parkway West Roxbury, MA 02132

USA

Gail.Grundy@va.gov Contract Specialist Email Provide all labor, material, and equipment necessary to replace fill on both cells of the building 3 Marley Model NC 8309G2 cooling tower, serial number 241518. This work covers both cells being shut down with removal and replacement of existing PVC fill materials, and replacement of all casing panels to restore the towers to their original design cooling capacity to include:

1. Disassembly of cooling tower fill and removal of old material by crane.

1. New material lifted to the roof by crane.

1. Disposal of old material by contractor in contractor provided dumpster.

1. Installation of new Marley MX75 LEV fill to manufactures specifications.

1. Installation of all new supports and new stainless-steel casing panels (16 total).

1. Use of new hardware and sealer.