36C24119Q0386-000.docx
DOCX document 22 KB Posted
- Attached to
- Certus Ablation System West Haven CT
- Solicitation number
- 36C24119Q0386
About this file
36C24119Q0386 36C24119Q0386.docx
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FedBizOpps Sources Sought Notice
CLASSIFICATION CODE
SUBJECT
CONTRACTING OFFICE'S
ZIP-CODE
SOLICITATION NUMBER
RESPONSE DATE (MM-DD-YYYY)
ARCHIVE
DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
SET-ASIDE
NAICS CODE
CONTRACTING OFFICE
ADDRESS
POINT OF CONTACT
(POC Information Automatically Filled from User Profile Unless Entered)
DESCRIPTION
See Attachment
AGENCY'S URL
URL DESCRIPTION
AGENCY CONTACT'S EMAIL
ADDRESS
EMAIL DESCRIPTION
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
GENERAL INFORMATION
PLACE OF PERFORMANCE
* = Required Field FedBizOpps Sources Sought Notice Rev. March 2010 Certus Ablation System West Haven CT 05009 36C24119Q0386 06-24-2019 N 334510 Department of Veterans Affairs VAMC White River Junction 215 North Main Street White River Junction VT 05009 Mary K. (Kathy) Bosch 802-296-5114 Mary.Bosch@va.gov West Haven VAMC 950 Campbell Avenue West Haven, CT 06516-2770
Justification and Approval for:
Other than Full and Open Competition The West Haven VA Medical Healthcare System intends to negotiate on a sole source basis pursuant to FAR 6.302‐1 ‐‐ Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements with Neuwave Medical or its authorized dealers for the purchase of a Certus 140 2.45GHZ Ablation System.
1 CERTUS 140 -2.45GHZ ABLATION SYSTEM 1 EA
BRAND NAME OR EQUAL TO:
Certus 140 - 2.45GHz Ablation System
Salient Characteristics
The ablation system shall contain the following Features:
- Ablation Confirmation-Imaging processing software to assist physicians in identifying ablation targets, assessing proper ablation probe placement and confirming ablation zones post-procedure.
- 2.45 GHz Wavelength
- Synchronized Energy Delivery Components
- Tissue-Loc technology to prevent probe migration and with real time temperature feedback
- Cooling System: CO2 -Probe ports per microwave unit: 3 total. One to Three probes can be Activated independently or simultaneously with one system.
-Max power total probes: 195W -Max power single probe: 140W -17 gauge probes: 15cm and 20cm Lengths. 13 gauge surgical probes 25cm length
- Tissue-specific probes: Liver/Kidney, Lung, Precision Precision Probe (PR): Forward weighted ablation zone, emitting 1cm back from tip.
- Active, real time temperature feedback on each probe, displayed on the touch screen monitor -Cauterize mode for track ablation.
-Touch Screen monitor -Call Home: Real time diagnostics, probe inventory management
- Bed mounted Power Distribution Module
- Triaxial probe design
Preference will be given to SDVOSB, VOSB Vendors/Contractors who are currently verifiable in the Vets First Verification Program of the Vetbiz Registry.
This Notice of Intent is NOT a request for competitive proposals. Parties may identify their interest, accompanied by supporting literature, to the Contract Specialist no later than June 24, 2019 at 12:00 p.m. Responses should be sent to Mary.Bosch@va.gov. Information received will used to determine whether or not to conduct a competitive procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.