36C10G19Q0075-004.docx

DOCX document 31 KB Posted

Attached to
NX EQ Pulse Oximeters (VA-19-00032743)
Solicitation number
36C10G19Q0075
Issued by

About this file

36C10G19Q0075 Attachment D Minimum Salient Characteristics- Pulse Oximeters.docx

View the file

Other files

File Type Posted
36C10G19Q0075-0001001.xlsx XLSX spreadsheet
36C10G19Q0075-0001000.docx DOCX document
36C10G19Q0075-0001002.docx DOCX document
36C10G19Q0075-005.docx DOCX document
36C10G19Q0075-006.xlsx XLSX spreadsheet
36C10G19Q0075-002.docx DOCX document
36C10G19Q0075-001.xlsx XLSX spreadsheet
36C10G19Q0075-003.docx DOCX document
36C10G19Q0075-000.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NONIN Brand or Equal

This requirement will be IAW FAR clause 52.211-6, “Brand Name or Equal” which requires that the vendor indicate each product that is being offered as an “equal” product. For each equal product, the vendor must include a description reflecting the characteristics and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified below. The vendor must clearly identify the item by brand name (if any) and make/model number. The vendor must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the contracting officer.

VENDORS SUBMITTING AN "OR EQUAL" QUOTE MUST MEET ALL THE MINIMUM SALIENT CHARACTERISTICS LISTED BELOW.

Minimum Salient Characteristics (SC) for Literature Review

CLIN
MFG
Part Number
Description

NONIN

EM-9509-3150

WristOx2, Mode 3150, Wrist worn Pulse Oximeter

SC
SALIENT CHARACTERISTICS
METHOD OF EVALUATION

SC 1

Must be small, lightweight and wearable

Literature Review

SC 2

Must be able to transfer data securely, via Bluetooth wireless or USB

SC3

Must have minimum of 12 hours battery life

SC 4

Must have an accurate response for capturing events in challenging conditions such as motion and low perfusion

SC 5

Must have minimum (1) one-year warranty

SC 6

Must have Oxygen Saturation display range of 0% to 100% SpO2

SC 7

Must have minimum pulse rate range of 25 to 240 pulses per minute

SC 8

Must have a three-digit numeric display and a pulse strength bar graph

CLIN
MFG
Part Number
Description

0002-0005

EM-9509-9590

EM-9509-959B

EM-9509-959R

EM-9509-959P

Onyx Vantage 9590 Finger Pulse Oximeter Black Onyx Vantage 9590 Finger Pulse Oximeter Blue Onyx Vantage 9590 Finger Pulse Oximeter Red Onyx Vantage 9590 Finger Pulse Oximeter Purple

SC
SALIENT CHARACTERISTICS
METHOD OF EVALUATION

Must be able to read SpO2 and pulse rate from any angle, in all lighting conditions, day or night

Must supply pulse quality indicator for quick assessment of pulse quality

Must automatically adjust to each patient from pediatric to adult

Must turn on and off automatically with insertion of digit

Must allow for minimum of 1800 spot checks or minimum of 30 hours of continuous operation, using two 2-AAA alkaline batteries

Must have a minimum 2-year warranty

Must have Oxygen Saturation display range of 0% to 100% SpO2

Must have a minimum pulse rate range of 30 to 240 pulses per minute

SC 9

Must have an oxygen saturation declared accuracy of 70-100%

CLIN
MFG
Part Number
Description

EM-9510-7500

7500 Series Tabletop Pulse Oximeter

SC
SALIENT CHARACTERISTICS
METHOD OF EVALUATION

Must be able to monitor neonate to adult patients in acute care to homecare environments

Must be flexible to be used as standalone device or interface with other equipment

Must have color coded Pulse Strength Bar Graph with audible tone with each tone

Must have a Pulse Quality Indicator

Must have a Sensor Fault Indicator that indicates when a sensor has become disconnected

Must have a min. of 70 hours memory

Must have at least a one-year warranty

Must have Oxygen Saturation display range of 1% to 100% SpO2

SC 9

Must have pulse rate range of 25 to 240 pulses per minute

SC 10

Must have an oxygen saturation declared accuracy of 70-100%