Tab_2_-_Pricing.pdf

PDF 324 KB Posted

Attached to
Roofing Products, Services, and Job-Order-Contracting Services
Contract number
72152601-24-OMNIA-ACS
Issued by
Florida

About this file

This document is a comprehensive pricing tab and contract pricing schedule for RoofConnect National Roofing Services, detailing rates and costs for various roofing, construction, and related services across multiple states. The document appears to be prepared for Region 4 ESC, a cooperative purchasing consortium, and provides detailed pricing coefficients and service rates for numerous roofing and construction activities across almost every U.S. state.

The pricing schedule covers an extensive range of roofing services including water-resistant roofing, insulation installation, roof restoration, masonry work, metal work, woodwork, solar panel installations, and specialized services like asbestos testing and roof inspections. Pricing is structured with unit costs (per square foot, linear foot, or each) for activities ranging from pressure cleaning and coating applications to complex demolition and reconstruction of roof components. The document includes state-specific coefficients for normal and non-normal working hours, a 15% markup on non-prepriced items, and provides granular pricing for specialized services such as skylight replacements, roof ladder installations, and emergency repairs. Additional notable features include warranty options, mileage rates, and detailed pricing for solar panel system components.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Number Unit of Measure

1 SF

2 SF

3 SF

4 SF

5 SF

6 SF

7 SF

8 LF

9 LF

10 LF

11 LF

12 LF

13 LF

14 LF

15 LF

16 LF

17 LF

18 LF

Number Unit of Measure

19 SF

20 SF

21 SF

Backer rod, polyethylene, 1/2” diameter, installed in prepared opening

1.92

Backer rod, polyethylene, 3/4” diameter, installed in prepared opening

1.95

Backer rod, polyethylene, 1” diameter, installed in prepared opening

2.03

Description of Cost Factors Offeror's Bid

Building paper, asphalt felt sheathing paper, 1 ply, 15#, in place

0.26

Building paper, asphalt felt sheathing paper, 1 ply, 40#, in place

36.66

Building paper, red rosin paper, 5 square rolls, 4#, in place

41.93

Non-pigmented synthetic resin, waterproofing, one coat sprayed on

0.47

Caulking: remove existing, clean and prime joint 5.2

Caulking, epoxied urethane compound, 2 component, 1/4” x 1/4”, in place

4.03

Caulking, polyurethane, 1 component, 1/4” x 1/4”, in place

3.09

Caulking, polyurethane, 1 component, 1/2” x 1/2”, in place

3.46

Caulking, silicone rubber, 1 component, 1/4” x 1/4”, in place

5.38

Caulking, epoxied urethane compound, 2 component, 1/4” x 1/4”, in place

4.16

Caulking, silicone rubber, 1 component, 3/4” x 3/8”, in place

7.48

Backer rod, polyethylene, 3/8” diameter, installed in prepared opening

1.9

PRICING TAB

Description of Cost Factors Offeror's Bid

Water Resistant Roofing Pressure cleaning, vertical walls 2.24

Pressure cleaning, horizontal surfaces 2.02

Roof scanning to identify wet or substandard room components to be removed 0.05

Asphalt emulsion coating, waterproofing, brush applied, per coat

0.39

Rubberized coating waterproofing, brush applied, per coat

7.22

Vinyl/acrylic resin, damp proofing, brush applied per coat.

1.53

22 SF

23 SF

24 SF

1 SF

2 SF

3a SF

3b SF

4a SF

4b SF

Number Unit of Measure

5 SF

6 SF

7a SF

7b SF

8a SF

8b SF

8c SF

Hot applications 0.68

Cold applications 0.85

Mechanically attached 1.5

Hot applications 1.03

Cold applications 1.29

Description of Cost Factors Offeror's Bid

Roof deck insulation, Isocyanurate in 4’ x 4’ or 4’ x 8’ sheets, 1” thick, R-6.6, mechanically fastened

1.76

Roof deck insulation, Isocyanurate in 4’ x 4’ or 4’ x 8’ sheets with fiberglass facers, 1 1/2” thick, R-10.0, mechanically fastened

1.95

Roof deck insulation, fiberboard in 4’ x 4’ sheets, 1/2” thick, R-1.39, applied Type IV asphalt

Hot applications 0.72

Cold applications 0.85

Roof deck insulation, fiberboard in 4’ x 8’ sheets, 25/32” thick, R-2.4, installed hot/cold or mechanically attached coated six sides

Vapor retarder; 2-ply inorganic, glass, Type IV, applied in cold adhesive to 4’ x 8’ x 1/4” glass-mat embedded, water resistant gypsum core panel mechanically fastened

3.37

Insulation

Demolition of roof insulation, per inch of depth 0.52

Demolition of lightweight cementitious fills, per inch of depth 1.63

Roof deck insulation, Isocyanurate in 4’ x 4’ or 4’ x 8’ sheets with fiberglass facers, 1” thick, R- 6.6, applied Type IV asphalt

Hot applications 0.87

Cold applications 1

Roof deck insulation, Isocyanurate in 4’ x 4’ or 4’ x 8’ sheets with fiberglass facers, 1 1/2” thick, R-10.0, applied Type IV asphalt

Vapor retarder adhered, 2 ply inorganic, glass Type 15, applied in Type IV (or appropriate type) asphalt, in place

26.83

Vapor retarder, 2 ply organic, Type 15 pound, applied in Type IV asphalt (or appropriate type), in place

35.69

9a SF

9b SF

10 SF

11 SF

12 SF

Number Unit of Measure

13 SF

14 SF

15 SF

16 SF

17 SF

18 SF

19a SF

19b SF

20a SF

20b SF

21a SF

21b SF

22a SF

22b SFSet into adhesive 1.89

Roof Tiles and Shingles

Set into adhesive 1.82

CDX Gypsum, 1/2" x 4' x 8'

Mechanically attached 1.5

Set into adhesive 1.95

CDX Gypsum with fiberglass, facer: 1/4" x 4' x 8'

Mechanically attached 1.3

Set into adhesive 1.63

CDX Gypsum with fiberglass facer: 1/2” x 4’ x 8’

Mechanically attached 1.5

Description of Cost Factors Offeror's Bid

Roof deck insulation, vermiculite at 1/8:12, R-value depending on thickness, per inch of depth 2.68

Roof deck insulation, vermiculite at 1/4:12, R-value depending on thickness, per inch of depth

3.42

Roof deck insulation, gypsum panels, 3” thick 5.07

Roof deck insulation, Isocyanurate (black facer only), tapered, 1/8” per foot slope, Type IV asphalt, per inch of depth

1.37

Roof deck insulation, Isocyanurate (black facer only), tapered, 1/4” per foot slope, Type IV asphalt, per inch of depth

1.5

Cold insulation adhesive 0.91

CDX Gypsum, 1/4" x 4' x 8'

Mechanically attached 1.37

Roof deck insulation, fiberboard in 4’ x 4’, 1” thick, R-2.78, applied Type IV asphalt (or appropriate asphalt), coated six sides

Hot applications 1.17

Cold applications 1.37

Roof deck insulation, fiberboard in 4' x 4' sheets, 1/2” thick, R-1.39, mechanically fastened, coated six sides

0.98

Roof deck insulation, fiberboard in 4’ x 4’, 1” thick, R-2.78, mechanically fastened, coated six sides

1.55

Roof deck insulation, lightweight cellular wire reinforced concrete fill, R- value depending on thickness, per inch of depth

0.78

1 SF

2 SF

Number Unit of Measure

3 SF

4 SF

5 SF

6 SF

7a Each

7b Each

8 SF

1 SF

2 SF

3 SF

4 SF

5 SF

6 SF

7 SF

8 SF

9 SF

10 SF

Number Unit of Measure

11 SF

2 SF

Remove single-ply roof, membrane mechanically attached

0.72

Remove copper sheet roofing 0.49

Base sheet, 3-ply fiberglass, Type IV (or appropriate type) asphalt (17 year roof)

3.12

Base sheet, 4-ply fiberglass, mechanically attached (17-year roof)

3.97

Fiberglass cap finishing membrane 1.11

Base sheet with 2 ply, fiberglass felts, Type IV asphalt (or appropriate type)

3.12

Base sheet with 3 ply, fiberglass felts, Type IV asphalt (or appropriate type)

3.97

Description of Cost Factors Offeror's Bid

Base sheet mechanically attached with 4 ply, Type VI fiberglass felts, Type IV (or appropriate type) asphalt

3.89

3.89Nail base sheet, 3 ply Type VI fiberglass felts, fiberglass cap, Type IV (or appropriate type) asphalt.

Shingles, fiberglass, Class A, 30-year, premium laminated multilayered 2.8

Replace clay or concrete roof tiles 18.2

Replace/repair other shingles 10.4

Self-adhering ice and water shield membrane for shingles, tiles, metal waterways, penetrations, valleys, ridges, edges, etc.

1.5

Roofing and Roof Restoration Remove built-up roof, multi-ply aggregate, non-asbestos, 1" thick or less

1.37

Remove single-ply roof: ballast, and membrane only

0.85

Remove single-ply roof, membrane partially or fully adhered

0.98

Remove composition shingles and felts to decking

0.98

Test for asbestos prior to removal 0.2

Description of Cost Factors Offeror's Bid

Remove clay, concrete, or slate roof tiles to decking

1.89

Remove wood shingles and felts to decking 0.98

Shingles, fiberglass, Class A, 25-year strip shingles, slopes 3:12 or greater 2.41

13 SF

14 SF

15 SF

16 SF

17 SF

18 SF

19 SF

20 SF

21 SF

22 SF

23 SF

24 SF

Number Unit of Measure

25 SF

26 SF

27 SF

28 SF

29 SF

30 SF

31 SF

32 SF

33 SF

Built-up roofing repairs; pitch-based mastic, with fiberglass mesh

2.67

Built-up roofing repairs; elastomeric mastic, with fiberglass mesh

3.56

Built-up roofing restoration, coal tar pitch roofs 1.37

Built-up roofing restoration, odorless, coal tar pitch or asphalt roofs

1.11

Built-up roof, modified bitumen adhesive, added cost per ply per square foot

0.59

Built-up roof, surface with cold asphaltic surfacing adhesive and gravel

1.5

Built-up roof, surface with emulsion and granules

1.29

Description of Cost Factors Offeror's Bid

Built-up roof, surface with emulsion and aluminum coating

1.39

Built-up roof, surface with emulsion and white elastomeric coating

1.46

Built-up roof, surface with aluminum coating or paint

1.5

Built-up roofing, surface with high solids white elastomeric coating

3.64

Built-up roofing repairs; fibered asphalt mastic, brush grade, with fiberglass mesh.

2.67

Base sheet with 4 ply; 2 polyester and 2 fiberglass felts, Type IV (or appropriate type) asphalt (20 year roof)

2.39

Built-up roof, base sheet with 3 ply polyester roofing sheet, Type IV (or appropriate type) asphalt (20 year roof)

2.08

Built-up roof, base sheet with 3 ply Type GS fiberglass, cold process adhesive (20 year roof)

3.61

Built-up roof base sheet plus 4 ply Type G2 fiberglass, cold process adhesive (30 year roof) 3.61

Built-up roof, base sheet, 1 ply Type VI fiberglass, 1 ply modified bitumen sheet, fire rated, Type IV asphalt (15 year roof)

4.88

Built-up roof, base sheet, 2 ply polyester roofing sheet, 1 ply modified bitumen sheet, fire rated, Type IV asphalt (or appropriate type) (20 year roof)

4.88

Built-up roof, base sheet, G-2, 33 lb., mechanically attached

0.72

Built-up roof, base sheet, G-2, 33 lb., Type IV asphalt

0.78

Built-up roof, premium asphalt, added cost per ply per square foot

0.33

34 SF

35 SF

36a SF

36b SF

36c SF

37 SF

38 SF

39 SF

40 SF

41 SF

Number Unit of Measure

42 SF

43 SF

44 SF

45 SF

46 SF

47 SF

48 SF

49 SF

50 SF

51 SF

52 SF

53 SF

54 SF

55 SF

56 SF

57 SF

Single ply roof, TPA Fleece Back, 45 mils fully adhered with hot asphalt

5.07

Single ply roof, 45 mils mechanically attached 3.25

Base sheet mechanically attached with 3 ply fiberglass felts, Type 1 - Coal Tar Pitch 2.28

Base sheet mechanically attached with 3 ply Organic felts, Type 1 - Coal Tar Pitch

2.34

Built-up roof, 4 ply Fiberglass felts, Type 1 Coal Tar Pitch

2.41

Build-up roof, 4 ply Organic felts, Type 1 Coal Tar Pitch

2.41

Additional Polyurethane foam coating 1.37

Single-ply roof, EDPM, 45 mils reinforced, mechanically fastened

2.41

Single-ply roof, EDPM, 60 mils fully adhered 2.54

Built-up roof, base sheet with 3 ply trilaminate ply, cold process adhesive (25 year roof)

3.45

Built-up roof, surface with premium asphalt, and gravel.

0.96

Built-up roof, surface with Fire Retardant Aluminum coating or paint, single coat

1.11

Modified Bitumen roof, base sheet, cap sheet, cold Modified Bitumen Adhesive

4.75

Built-up roof, 3 ply fiberglass felts, Type IV asphalt

3.51

Single ply Roof, 45 mils fully adhered with bonding adhesive

4.23

PVC 2.28

EPDM 2.15

Flashing membrane, 2 ply, Type IV or Type VI fiberglass

1.5

Flashing membrane, 1 ply polyester and 1 ply modified bitumen

2.93

Flashing membrane, 2 ply, polyester 1.63

Flashing membrane, CSPE 1.82

Flashing membrane, CSPE with aluminum coating

2.15

Description of Cost Factors Offeror's Bid

Polyurethane foam roofing 3.97

Single-ply roof, CSPE, 45 mils reinforced, asbestos free, mechanically fastened 2.28

Single-ply roof, CSPE, 60 mils reinforced, asbestos free, mechanically fastened 2.54

Single-ply roofing repairs (CSPE, PVC, and

EPDM)

CSPE 2.28

58 SF

59 SF

Number Unit of Measure

60 SF

61 SF

62 SF

63 SF

1 SF

2 SF

3 SF

4 Each

5 Each

6a

6b Each

6c SF

6d SF

7a SF

7b SF

Number Unit of Measure

7c SF

7d SF

Description of Cost Factors Offeror's Bid

Removal of existing mortar (½” wide by 1½” depth)

5.81

Removal of existing mortar (¾” wide by 1½” depth)

7.4

Coping stones, remove and reset 39.33

Brick, block or coping removal 17.23

Brick, block and brick exterior wall maintenance, repair and application of protective coatings.

Selective Demolition of Concrete Block Masonry Units (CMU) with perimeter saw cutting- swingstage 4”, 6” and 8” block (high-rise)

9.09

Selective Demolition of Brick Masonry Units with perimeter saw cutting - swingstage one, two, and three wythe (high-rise)

24.58

Selective Demolition of Brick Masonry Units with perimeter saw cutting - scaffolding one, two and three wythe (low-rise)

17.45

Selective Demolition of Mortar Joint with Perimeter Sawcutting – Swingstage (high-rise)

Removal of existing mortar ( ½” wide by ¾” depth)

3.17

Removal of existing mortar (¾” wide by ¾” depth)

5.28

Single ply repairs at laps or defects using 2 coats elastomeric coating system with reinforcement 4.23

Single ply roof, TPA fleece back, 60 mils fully adhered with hot asphalt

5.4

Single ply roof 60 mils fully adhered with bonding adhesive

3.97

Built-up roof, 1 ply Trilaminate, 1 ply Modified Bitumen Sheet, fire rated

4.23

Masonry Brick, remove and reset, 1 to 50 sq ft 19.85

Brick, remove and reset, over 50 sq ft 15.26

Block, remove and reset 16.52

Built-up roof, surface with hot Coal Tar Pitch and gravel

2.02

Single ply repairs using 2 coat polyurethane, elastomeric coating system 4.23

Description of Cost Factors Offeror's Bid

8a SF

8b SF

8c SF

8d SF

9a SF

9b SF

9c SF

9d SF

Number Unit of Measure

10a SF

10b SF

10c SF

Furnish and install new mortar (½” wide by ¾” depth)

6.33

Furnish and install new mortar (¾” wide by ¾” depth)

7.19

Furnish and install new mortar (½” wide by 1 ½” depth)

6.97

Furnish and install new mortar (¾” wide by 1 ½” depth)

8.24

Description of Cost Factors Offeror's Bid

New Pointing Work – Scaffolding (low- rise)

Furnish and install new mortar (½” wide by ¾” depth)

5.07

Furnish and install new mortar (¾” wide by ¾” depth)

5.71

Furnish and install new mortar (½” wide by 1 ½” depth)

5.92

Selective Demolition of Mortar Joint with Perimeter Sawcutting – Scaffolding (low-rise)

Removal of existing mortar ( ½” wide by ¾” depth)

5.53

Removal of existing mortar (¾” wide by ¾” depth)

5.59

Removal of existing mortar (½” wide by 1½” depth)

6.05

Removal of existing mortar (¾” wide by 1½” depth)

6.33

New Pointing Work – Swingstage (high- rise)

10d SF

11a SF

11b SF

11c SF

11d SF

Number Unit of Measure

12a SF

12b SF

12c SF

12d SF

13a SF

13b SF

13c SF

13d SF

Removal of 3 wythe brick parapet wall (42” high)

118.73

Removal of 2 wythe brick parapet wall (24” high)

55.47

Removal of 3 wythe brick parapet wall (42” high) 110.93

Reconstruction of Brick Masonry Roof Parapets

– Swingstage (high-rise)

New brick masonry parapet w/stone coping and flashings (3 wythe - 24” high) 288.6

New brick masonry parapet w/stone coping and flashings (3 wythe - 42” high) 364.87

New brick masonry parapet w/stone coping and flashings (2 wythe - 24” high) 214.07

New brick masonry parapet w/stone coping and flashings (2 wythe - 42” high) 266.93

Reconstruction of Brick Masonry Roof Parapets

– Scaffolding (low-rise)

Furnish and install new mortar (¾” wide by 1 ½” depth)

6.77

Removal of Roof Parapets – Swingstage (high-rise)

Removal of 3 wythe brick parapet wall (24” high)

97.07

Removal of 3 wythe brick parapet wall (42” high)

171.6

Removal of 2 wythe brick parapet wall (24” high)

81.47

Removal of 3 wythe brick parapet wall (42” high)

149.93

Description of Cost Factors Offeror's Bid

Removal of Roof Parapets – Scaffolding (low-rise)

Removal of 3 wythe brick parapet wall (24” high)

65.87

14a SF

14b SF

14c SF

14d SF

15a SF

15b SF

15c SF

15d SF

15e SF

16a SF

16b SF

16c SF

16d SF

16e SF

Number Unit of Measure

17a SF

17b SF

18a SF

18b SF

18c SF

18d SF

Description of Cost Factors Offeror's Bid

Drilling and installation of new friction pins with mortar cap

18.2

Drilling and installation of new friction pins for lime stone with mortar cap

28.6

Limestone Removal and Replacement.

Removal of existing deteriorated architectural limestone

65.87

Furnish and install new limestone replacement.

189.8

Replacement of stone with lightweight polymer resin to match

76.27

Minor patching of existing stone to match

121.33

Furnish and install new flashings (Lead coated copper)

23.4

Parging and waterproofing of back-up wall 18.2

New Throughwall Flashings – Scaffolding (low-rise) Removal of 4 courses 1 wythe brick wall w/Temporary Shoring

66.73

Removal and replacement of steel lintel 39

Furnish and install new flashings (Bituthane) 10.4

Furnish and install new flashings (Lead coated copper)

20.8

Parging and waterproofing of back-up wall 14.73

Brick Masonry/Stone Stabilization

Description of Cost Factors Offeror's Bid

New brick masonry parapet w/stone coping and flashings (3 wythe - 24” high)

184.6

b) New brick masonry parapet w/stone coping and flashings (3 wythe - 42” high)

250.47

c) New brick masonry parapet w/stone coping and flashings (2 wythe - 24” high)

131.73

d) New brick masonry parapet w/stone coping and flashings (2 wythe - 42” high)

193.27

New Throughwall Flashings – Swingstage (high-rise) Removal of 4 courses 1 wythe brick wall w/Temporary Shoring

83.2

Removal and replacement of steel lintel 41.6

Furnish and install new flashings (Bituthane) 13

19a SF

19b SF

19c SF

19d SF

20a SF

20b SF

20c SF

20d SF

20e SF

20f SF

20g SF

20h SF

Number Unit of Measure

21a SF

21b SF

21c SF

22a SF

22b SF

22c SF

23a Each

23b SF

23c SF

24a SF

24b SF

24c SF

25a SF

25b SF

25c SF

25d SF

25e SF

Perimeter sawcutting 1.3

Removal of existing concrete (2” depth). 18.2

Removal of existing concrete (3.5” depth). 23.4

New Concrete and Coating

Placement of new high strength patching mortar (2” depth)

65.87

Placement of new high strength patching mortar (3.5” depth).

73.67

Cleaning and coating of concrete surface. 6.07

Sidewalk Bridging. 206.27

Temporary Roof Protection 1.31

Brick Masonry Piers

Isolated repair of existing masonry piers (removal and replacement)

118.73

Reconstruction of isolated areas of pier 106.6

Construction of new masonry piers. 85.8

Crack Repair

Drill and install new stainless steel pins. 19.07

Grouting of open cracks 13

Replacement of cracked bricks 26

Concrete Removal

Reinstallation of existing stones with cleaning 38.13

Furnish and install new coping stones 86.67

Furnish and install new sealants between coping stones.

6.67

Cleaning and coating of existing stones. 6.93

CMU Backup Wall Repair and Waterproofing.

Description of Cost Factors Offeror's Bid

Replacement of Deteriorated CMU Back-up 44.2

Parging of CMU back-up wall 11.27

Waterproofing of back-up wall 6.07

Removal of existing deteriorated architectural Terra Cotta

65.87

Furnish and install new Terra Cotta replacement.

210.6

Replacement of stone with lightweight polymer resin to match

76.27

Minor patching of existing stone to match 121.33

Roof Coping Stones.

Removal of existing roof coping stones (16 inches)

65.87

Removal and parging of existing substrate 14.73

Furnish and install new lead coated copper flashings

20.8

Drilling and epoxy grouting stainless steel pins 19.07

Terra Cotta Removal and Replacement.

26a SF

26b SF

27 SF

27a SF

27b SF

28 LF

28a LF

Number Unit of Measure

28b LF

29 LF

29a LF

29b LF

30 LF

30a LF

30b LF

30c LF

30d LF

31 LF

31a LF

31b LF

31c LF

31d LF

31e Each

31f LF

31g Each

31h Each

31i SF

31j Each

31k SF

Metal splash pan, 16 oz. 23.73

Metal trim, aluminum, .032" thick, painted

5.53

Metal storm collar 31.85

Metal coping, galvanized steel, 24 gauge, standing seam

16.25

Gutter, copper, 16 oz, half round, 6" wide 29.19

Remove metal downspouts 5.79

Downspouts, aluminum, .024" thick, 3" x 4", painted, installed

15.93

Downspouts, GI, 24 gauge 3" x 4" installed

19.83

Downspouts, GI, 24 gauge, 4" round, installed 18.88

Downspouts, copper, 16 oz., 6" round, installed 20.41

Downspouts, strainer 3.25

Metal flashing, apron flashing, 9" wide 8.78

Metal flashing, step flashing 16.25

Description of Cost Factors Offeror's Bid

Counterflashing, copper, 16 oz., 6" width

11.05

Remove metal edge, gravel stop, eave strip, or coping

1.95

Metal edge raised, galvanized steel fascia/eave drip; 6" face, hemmed, continuous cleat, 3" deck flange

6.5

Gravel stop, galvanized steel, 24 gauge, 6" face 6.83

Remove metal gutter 3.25

Gutter, galvanized steel, ASTM 526, with 12.5oz./square foot galvanized coating, 24 gauge, 5" box or ogee style, joints and end caps shall be soldered

19.5

Gutter, aluminum, .050" thick 5" box or ogee, painted, Kynar finish

24.7

Gutter, copper, 16 oz, half round, 5" wide 18.53

Metal Work Remove standard metal decking 1.37

Install metal decking; 1-1/2" deep, 20 gauge, standard profile

5.07

Install steel plate, two sizes 4.55

10 Gauge, standard application 2.28

Extra heavy-duty 1/4th inch 1.63

Remove metal counterflashing 2.34

Counterflashing, galvanized, 24 gauge, 6" width 4.55

31L SF

31m LF

31n SF

31n SF

31o SF

31p SF

31q SF

31r SF

31s SF

32a SF

32b SF

32c SF

32d SF

33a SF

33b SF

33c SF

34a SF

Number Unit of Measure

34b SF

34c SF

35a SF

35b SF

35c SF

Exterior rated gypsum board sheathing and substrate

3.94

Woodwork Demolition of plywood or standard 1” x 6” decking

1.24

Demolition of standard 2” x 6” tongue and groove decking

1.5

Plywood decking, CDX, 1/2” thick (or 15/32" optional)

2.67

Cladding of roof parapet walls with copings.

27.73

New Exterior Insulation and Finish System

(EIFS)

New Exterior Insulation and Finish System

(EIFS)

42.9

New Exterior Insulation Finish System (EIFS) w/o insulation

27.01

New Metal Copings. 23.39

Surface Preparation

Cleaning of existing steel and surface. 3.03

Description of Cost Factors Offeror's Bid

Coating of existing reinforcement 3.72

Parapet wall metal 12.81

Metal edge, anodized finished aluminum, free floating fascia system 8 inches 48.36

Metal edge, high performance fluorocarbon finished aluminum, free floating fascia system 8 inches

21.91

Metal edge, anodized finished aluminum, free floating fascia system 6 inches

19.47

Metal edge, high performance fluorocarbon finished aluminum, free floating fascia system 6 inches

17.03

New Aluminum Metal Cladding

Furnish and install new uninsulated aluminum wall cladding

19.7

Furnish and install new insulated aluminum wall cladding

30.68

Furnish and install new insulated aluminum wall cladding panels (Architecture 41.6

Description of Cost Factors Offeror's Bid

Metal coping, galvanized steel, 24 gauge, with butt plate

16.25

Resolder joints in sheet metal 4.23

Metal edge, aluminum, 0.50 thick 6" face painted

23.08

Metal edge, aluminum, free floating fascia system

26.65

35d SF

35e SF

35f SF

35g SF

35h LF

35i LF

35j LF

35k LF

36a LF

36b LF

36c LF

37a LF

37b LF

38a LF

38b LF

Number Unit of Measure

39a SF

39b LF

39c SF

39d SF

39e Each

39f SF

39g SF

39h LF

39i SF

39j LF

39k LF

40a LF

40b LF

41a Each

Gutter liners 20.54

Flashing 10.99

Expansion joints 26.65

Finishing touches (no additional cost in contract)

Snow retention assemblies 22.75

Self-adhering ice and water shield membrane for shingles, tiles, metal waterways, penetrations, valleys, ridges, edges, etc.

1.5

Roof Specialties and Accessories Remove roof hatch 325

Description of Cost Factors Offeror's Bid

Pre-Engineered SSMRS, products (20- year roof)

45.44

Subpurlins 7.02

Roof panel installation 5.85

Field forming of panels 4.88

Concealed anchor clips 1.63

Vapor retarder installation 1.6

Insulation installation 4.88

Gutters (SSMRS only) 18.19

Curbing, SBX treated wood, 2” x 12” 9.5

Joist, fir

2” x 6” 4.49

2" x 8" optional 4.97

Joist, fir

2" x 10" 5.14

2" x 12" optional 6.11

Standing Seam Metal Roof System (SSMRS) Price Each Specification Using Line Items

Standard 2” x 6” tongue and groove decking 6.31

Cants, wood fiber, trapezoidal, 1 1/2” x 5 5/8” 1.63

Cants, SBX treated wood, 4” x 4” diagonal

5.33

Nailer, SBX treated wood, 1” x 4” 2.93

Nailer, SBX treated wood, 2” x 4” 4.23

Nailer, SBX treated wood

2" x 6" 5.28

2" x 8" optional 6.34

Plywood decking, CDX, 5/8” thick 2.99

Plywood decking, CDX, 3/4” thick 4.62

Standard 1” x 6” decking, tongue and groove 5.66

41b Each

41c SF

41d Each

41e Each

41f Each

41g Each

41h Each

41i Each

41j SF

Number Unit of Measure

41k LF

41L LF

42a LF

42b LF

42c LF

42d Each

42e LF

42f LF

42g Each

42h LF

42i Each

42j Each

43a Each

43b Each

43c LF

43d LF

43e Each

43f Each

44a SF

Expansion joint, butyl or neoprene bellows, galvanized flange

23.39

Expansion joint, CSPE reinforced 20.79

Repair kit for dry repairs 62.39

Repair kit for wet repairs 62.39

Skylights (price each size and lens combination)

Standard 3' x 5', 4' x 4', 4' x 8' with single clear lenses

38.32

Roof ladder, steel, bolted to concrete, up to 20 feet, without cage

97.5

Roof ladder, steel, bolted to concrete, 20 feet and up, with cage; with intermediate landings as required by Code

162.5

Roof ladder, security ladder guard 780

Termination bar, aluminum, 1/4” x 1” 1.95

Pitch pocket, 24 gauge, GI, 6” x 6”, with storm collar hemmed to outside, soldered corners and seams

Pitch pocket, 24 gauge, GI, 8” x 8”, with storm collar, hemmed to oytside, soldered corners and seams

Pitch pocket, resurface top only

8" x 8" 6.23

12" x 12" 7.53

Remove existing walkway, built-up roofs 0.98

Description of Cost Factors Offeror's Bid

Walkway, built-up roofs, desert tan fiberglass 4.75

Walkway, built up roofs, non skid 9.75

Walkway, single ply roof

30" wide roll goods, tape attached 3.58

30" wide roll, hot asphalt attached 3.45

30" wide roll, adhesive attached 3.76

Roof ventilators 195

Roof hatch, aluminum, 2’6” x 3’0” 853.13

Roof hatch, aluminum, larger sizes 120.25

Remove existing roof drain, except plumbing

Install new roof 4" drain, except plumbing 1508

Install new roof 6" drain, except plumbing 1664

Reflash existing roof drain 214.5

Plumbing stack, 4# lead flashing 97.5

Scupper, sheet steel, 24 gauge ASTM A 526, match existing configuration

44b SF

Measure

44c SF

44d SF

45a Each

45b Each

45c Each

45d SF

46a Each

46b Each

46c Each

46d SF

46e Each

46f Each

46g Day

46h SF

46i SF

46j SF

46k Per Project

46L Per Project

Number Unit of Measure

46m Per Project

46n Per Project

46o Per Project

Prime contractor’s warranty, restoration, less than 10,000 sq ft, minimum charge

Prime contractor’s warranty, restoration, over 10,000 sq ft, minimum charge

0.1

Description of Cost Factors Offeror's Bid

Prime contractor’s warranty, re-roof, total system, 15 year, less than 10,000 sq ft, minimum charge (Standard)

Prime contractor’s warranty, re-roof, total system, 15 year, less than 10,000 sq ft, minimum charge (includes 2, 5, 7, 10, 15 year inspections)

0.1

Prime contractor’s warranty, re-roof, total system, 15 year, more than 10,000 sq ft, minimum charge (Standard)

Core analysis, 14” x 14” and patch of existing roof surface

Non destructive roof scan, up to 50,000 sq ft, full service each

Additional foot over 50,000 sq ft

0.04

Non destructive roof scan, up to 50,000 sq ft, limited service

Additional foot over 50,000 sq ft

0.04

Roof inspection services (visual inspection of roofing service/membrane, flashings, counterflashings, copings, parapets, trims, hatches, penetrations, curbs, roof-mounted equipment, etc. with a written report of findings and recommendations

Field/shop drawings, up to 10,000 sq ft 0.07

Field/shop drawings, 10,000-50,000 sq ft 0.07

Field/shop drawings, over 50,000 sq ft 0.07

Skylight lense replacement only, double clear 54.28

Security/fall bars for skylights

3' x 5' 455

4' x 4' 455

4' x 8' 650

Special sizes 37.17

Roof Services Asbestos core testing and patch of existing roof surface

149.5

Standard 3' x 5', 4' x 4', 4' x 8' with clear double lenses

56.85

Description of Cost Factors Offeror's Bid

Skylight lense replacement only, clear 34.62

46p Per Project

46q Per Day

46r Day

46s SF

46t SF

46u Day

47a SF

47b SF

47c SF

47d SF

47e Day

47f Day

47g Each

Number Unit of Measure

47h Each

47i Each

48a % of Discount

48b % of O/P

48c % of discount

48d % to be applied

51 Day

Multiplier/factor to be applied to the R.S. Means costs.

Deducts and add-ons for in lieu products (Place behind Tab 6) Special Rental Equipment (Priced based on

9.11.2 above) Cold and bad weather storage identify extra cost if any

$200

Hourly Services Rates

Minor roof repair calls 650

Difficult access or fall restriction;

surcharge

15%

Description of Cost Factors Offeror's Bid

Excessive hauling 130

Work in secured areas or compounds; surcharge 10%

Additional and occasional supplies, materials, equipment and services Additional and occasional services Roofing supplies Discount off Retail Price List 5%

Alternative Methods of Costing - percent of overhead/markup and profit added to cost 25%

Discounts Offered Off Alternative Costing Methods (cost plus profit and overhead) Less Rate of Discount

5%

Asbestos abatement activities, BUR removal and disposal of waste

27.94

Project site is located 65 or more miles from the contractor's/subcontractor's yard/home location.

1.89

Asbestos site monitoring 650

Annual or semi-annual roof housekeeping-per location Cost once a year per location if less than 20,000

sq. ft.

0.16

Cost per Sq.ft. per year per location if greater than 20,000 sq.ft.

0.1

Cost semi-annual per location if less than 20,000 sq. ft

0.18

Cost per Sq.ft. semi annual per location if greater than 20,000 sq.ft.

0.16

Roof leak investigation 650

Prime contractor’s warranty, re-roof, total system, 15 year, more than 10,000 sq ft, minimum charge (includes 2, 5, 7, 10, 15 year inspections)

0.1

Per diem rate per worker per 24 hour period of time

71.5

Prime contractors per diem/costs for asbestos abatement planning

188.5

53 Per Hour

54 Per Hour

55 Per Hour

56 Per Hour

57a Per Mile

57b Percent

57c Dollar Amount

Number Unit of Measure

58 Solar Panels 58a Per Watt

58b Per Watt

58c Per Watt

58d Per Watt

58e Per Watt

58f Per Watt

Coefficient Non- Normal

Working Hours

Coefficient Normal

Working Hours

Coefficient Non- Normal

Working Hours

1.5 1 1.5

2.58 1.25 1.88

1.5 1 1.5

1.5 1.2 1.8

1.91 1.17 1.76

1.5 1.24 1.86

Arizona 1 Nebraska Arkansas 1 Nevada California 1.27 New Hampshire Colorado 1 New Jersey

**NOTE: Complete and submit line items for this section.

Proposed Pricing Coefficient (s)

Please provide Coefficients for products and services not listed in the provided line items for states that you are proposing to do work in.

COEFFICIENTS NORMAL WORKING HOURS; the priced coefficients for each region that you are willing to work in shall be listed for both regular hours (7A.M. to 6 P.M.)

COEFFICENT NON-NORMAL WORKING HOURS; the priced coefficient for weekends, holidays and hours outside of regular hours. The coefficient must be rounded to the nearest second decimal place, e.g. .793 would be rounded to .79.

Coefficients:

State Coefficient Normal

Working Hours

State

Alabama 1 Missouri Alaska 1.72 Montana

Inverters 0.57

Ground Racking 0.61

Roof racking 0.61

BOS (Electrical wire, boxes, conduit, disconnect etc.) 0.66

Installation Labor

**NOTE: Complete and submit line items for this section.

Value Add/Balance of Line

1.32

General Cost Factors Mileage rate 0.6

Performance and payment bond - bonding rate (percent of project) varies

Bonding capacity - total amount of capacity available varies

Description of Cost Factors Offeror's Bid

System

Solar Modules (panels) Tier 1 0.75

Structural Analysis/engineering services 240.5

Architect/design professional services 240.5

Roofing Consultant 169

Labor Rate for Roofer 115.7

1.95 1 1.5

1.76 1.42 2.13

1.5 1 1.5

1.5 1.18 1.77

1.5 1 1.5

2.58 1 1.5

1.98 1.12 1.68

1.98 1 1.5

1.71 1.21 1.82

1.65 1 1.5

1.5 1 1.5

1.5 1 1.5

1.5 1 1.5

1.65 1 1.5

1.5 1 1.5

1.98 1 1.5

1.5 1.25 1.88

1.5 1.1 1.65

1.5 1.2 1.8

1 1.5

Michigan 1 Washington Minnesota 1 West Virginia Mississippi 1 Wisconsin

Wyoming

Note: Provide coefficients for the state(s) that you would like to be awarded. Region 4 ESC is looking for proposers that can provide service in multiple states.

Provide markup percentage on non-prepriced items 15% .

Kentucky 1 Tennessee Louisiana 1 Texas

Maine 1.1 Utah Maryland 1 Vermont

Massachusetts 1.32 Virginia

Idaho 1.32 Oregon Illinois 1.32 Pennsylvania Indiana 1.14 Rhode Island

Iowa 1.1 South Carolina Kansas 1 South Dakota

Delaware 1.17 New York District of Columbia 1 North Carolina

Florida 1 North Dakota Georgia 1 Ohio Hawaii 1.72 Oklahoma

Connecticut 1.3 New Mexico

File details come from the government source that posted it. Updated .