25-0603_L2 Board Room AV Set.pdf
PDF 1 MB Posted
- Attached to
- BWC AV Upgrades State and local contract opportunity
- Solicitation number
- SRC0000031686
- Issued by
- Franklin County, Ohio
About this file
This document is a set of architectural and engineering plans for a Board Room Renovation project at the William Green Building, located at 30 W. Spring Street in Columbus, Ohio, for the Bureau of Workers' Compensation (BWC). The project involves renovating Room 3 (Room 02104) on Level 2, with a scope of work that includes monitor installation, electrical work, and speaker replacement. The project area will be unoccupied during renovation, while other areas of Level 2 will remain open for BWC and public use. Work is permitted during normal business hours, with any after-hours work requiring coordination with the project coordinator.
The renovation includes installing a 75" and a 65" LG monitor with dedicated electrical and mounting, removing existing speakers, and updating the ceiling grid and tiles. Specific technical requirements include running all data and electrical cabling below the floor, installing new data outlets in pairs, and connecting HDMI cables back to a sound booth. The project involves precise mounting specifications, using Sanus Elite Full Motion Wall Mounts, and ensuring all electrical and data installations are concealed and do not interfere with mount installations. The project contacts include Haley Grunkemeyer (Project Coordinator), Kevin Smith (Assistant Director of Facilities), and Jeff Pitt (Building Manager) from the Bureau of Workers' Compensation.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| 25-0603_L2 Board Room AV Scope.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
UP
1 1
N
E F
WILLIAM GREEN BUILDING LEVEL 2 BOARD ROOM RENOVATION
CS COVER SHEET
E-1 ELECTRICAL PLAN
E-2 MONITOR ELEVATIONS
RCP-1 REFLECTED CEILING DEMOLITION PLAN
RCP-2 NEW REFLECTED CEILING PLAN
30 W. SPRING STREET, B2
COLUMBUS, OH 43215
DRAWING INDEX GENERAL NOTES
BWC FACILITIES
HALEY GRUNKEMEYER, PROJECT COORDINATOR
E: HALEY.G.2@BWC.OHIO.GOV
P: (614) 752-5991
KEVIN SMITH, ASSISTANT DIRECTOR OF FACILITIES
E: KEVIN.S.3@BWC.OHIO.GOV
P: (614) 644-7939
BUILDING MANAGEMENT
JEFF PITT, BUILDING MANAGER
E: JEFF.P.12@BWC.OHIO.GOV
P: (614) 402-4813
PROJECT CONTACTS
EXISTING CONDITIONS TO BE SURVEYED PRIOR
TO WORK. ANY DISCREPANCIES BETWEEN
DRAWN AND BUILT CONDITIONS ARE TO BE MADE
KNOWN TO THE BWC PROJECT COORDINATOR.
WORK IS PERMITTED DURING BWC NORMAL
BUSINESS HOURS. WORK IS NOT TO START PRIOR
TO 7AM. IF PART OF SCOPE NEEDS TO BE
COMPLETED AFTER NORMAL HOURS,
COORDINATION WITH THE PROJECT
COORDINATOR IS REQUIRED.
PROJECT AREA WILL BE UNOCCUPIED FOR THE
DURATION OF THIS PROJECT. ALL OTHER AREAS
OF LEVEL 2 WILL BE OPEN FOR BWC AND PUBLIC
USE. ALL MEANS OF EGRESS MUST BE
MAINTAINED.
WORK SHALL BE COMPLETED IN ACCORDANCE
WITH THE SCHEDULE SET FORTH BY BWC AND
COLEMAN-SPOHN.
REMOVAL OF DEBRIS SHALL BE THE
RESPONSIBILITY OF CONTRACTOR. DEMOLITION
AND CONSTRUCTION DEBRIS SHALL BE REMOVED
IN ACCORDANCE WITH BWC BUILDING
MANAGEMENT.
CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
A CLEAN AND USEABLE WORK AREA AT
COMPLETION OF EACH DAY.
CONTRACTOR IS RESPONSIBLE FOR REPAIRING
EXISTING CONDITIONS THAT ARE DAMAGED AS A
RESULT OF CONSTRUCTION.
SCOPE OF WORK
THIS PROJECT INCLUDES, BUT IS NOT LIMITED TO,
THE FOLLOWING SCOPES OF WORK:
· MONITOR INSTALLATION
· ELECTRICAL
· SPEAKER REPLACEMENT
AREA OF WORK
L-2 KEY PLAN
SCALE: N.T.S.
WILLIAM GREEN BUILDING SITE PLAN
SCALE: N.T.S.
ELECTRICAL
CLOSET
AutoCAD SHX Text P
ROOM 3
02104
E E
E
B
E
B
E
BE T
E
B
E
E
E
E
E
B ET
E
B
E E
E
B EF
E
B
E
B
E T
" M
O N
IT
O
R
" M O
N
IT
O R
" M
O N
IT
O
R R F
A E-2
B E-2
" M
O N
IT
O
R
L-
B O
A R
D R
O O
M R
EN
O
VA
TI
O N
EL
EC
TR
IC
A L
PL
A
N
REVISIONS
DATE:
E-1
06/03/2025
WILLIAM GREEN
BUILDING
30 W. SPRING STREET
COLUMBUS, OH 43215
NUM. DATE
DRAWN BY: HG
LEGEND
EXISTING WALL
NEW WALL
EXISTING DOOR
CASEWORK
DUPLEX OUTLET
CODED NOTES
INSTALL 75" LG MONITOR, MOUNT,
AND DEDICATED ELECTRICAL.
INSTALL 65" LG MONITOR, MOUNT,
AND DEDICATED ELECTRICAL.
QUAD OUTLET
WALL DATA
B BLANK PLATE
F FIRE STROBE
T THERMOSTAT
EXISTING, NEW, RELOCATEE, N, R
GENERAL NOTES
1. CONTRACTOR TO INSTALL NEW
ELECTRICAL FOR A/V MONITOR.
REFERENCE SHEET E-2.
2. CONTRACTOR MAY RE-USE
EXISTING HDMI CABLES IN CEILING
WHERE PROJECTOR WAS
REMOVED, IF APPLICABLE.
F I R E
5' -8
/2
C
EN
TE
R O
F M
O N
IT
O
R
C L
4' -4
BO
TT
O
M O
F M
O N
IT
O
R
4' -8
C
EN
TE
R O
F
EL
EC
TR
IC
AL
C L
1 2 3
5' -9
C
EN
TE
R O
F M
O U
N T
C L
7' -1
TO
P O
F M
O N
IT
O
R
4' -5
C
EN
TE
R O
F
EL
EC
TR
IC
AL
C L
5' -6
C
EN
TE
R O
F M
O N
IT
O
R
C L
3' -1
1"
BO
TT
O
M O
F M
O N
IT
O
R
1 2 3
5'
-8
C
EN
TE
R
O F
M O
U N
T
C L
7' -1
TO
P O
F M
O N
IT
O
R
L-
B O
A R
D R
O O
M R
EN
O
VA
TI
O N
A /V
E
LE
VA
TI
O N
S
REVISIONS
DATE:
E-2
06/03/2025
WILLIAM GREEN
BUILDING
30 W. SPRING STREET
COLUMBUS, OH 43215
NUM. DATE
DRAWN BY: HG
65" MONITOR INSTALL ELEVATION
SCALE: 3/8" = 1'-0"A
75" MONITOR INSTALL ELEVATION
SCALE: 3/8" = 1'-0"B
CODED NOTES
NEW QUAD ELECTRIC OUTLET
NEW HDMI OUTLET
NEW DATA OUTLET
1 PRIMARY, 1 SECONDARY
SANUS ELITE FULL MOTION WALL
MOUNT, BLACK BRUSHED METAL
65" MONITOR
75" MONITOR
GENERAL NOTES
1. INSTALL ELECTRICAL FOR MONITOR
IN A MANNER SO IT'S CONCEALED
FROM VIEW AND DOES NOT
INTERFERE WITH MOUNT
INSTALLATION.
2. ALL NEW DATA IS TO BE PROVIDED
IN PAIRS. PAIR = 1 PRIMARY, 1
SECONDARY
3. CONTRACTOR TO INSTALL CAT6
HOMERUNS FROM PATCH PANEL TO
FACEPLATES. TERMINATE WITH
RJ45 JACKS PER BWC
SPECIFICATIONS.
4. ALL DATA & ELECTRICAL CABLING IS
TO BE RUN BELOW THE FLOOR. NO
CABLING IS TO BE RUN ON TOP OF
THE FLOOR.
5. ALL A/V EQUIPMENT TO BE FED
FROM SOUND BOOTH AT ENTRY.
BWC TO PROVIDE HDMI SPLITTER.
CONTRACTOR TO INSTALL NEW
HDMI BACK TO SOUND BOOTH FOR
EACH MONITOR LOCATION.
S
S
S
WAP
S
S S
S
S
S
S
S
S
E
CM
E
CM
TYP
TYP
L-
B O
A R
D R
O O
M R
EN
O
VA
TI
O N
C
EI
LI
N
G D
EM
O
LI
TI
O N
P
LA
N
REVISIONS
DATE:
RCP-1
06/03/2025
WILLIAM GREEN
BUILDING
30 W. SPRING STREET
COLUMBUS, OH 43215
NUM. DATE
DRAWN BY: HG
LEGEND
EXISTING WALL
NEW WALL
EXISTING DOOR
CASEWORK
CODED NOTES
REMOVE SPEAKER, TYP. OF (10)1
GENERAL NOTES
1. RE-USE EXISTING WIRING FOR
SPEAKERS, IF APPLICABLE. PULL
ANY UN-USED WIRES BACK TO
THE NEAREST JUNCTION BOX.
2. CONTRACTOR MAY RE-USE
EXISTING HDMI CABLES IN
CEILING WHERE PROJECTOR WAS
REMOVED, IF APPLICABLE.
2x4 FIXTURE
DOWNLIGHT
2x2 DIFFUSER
S SPEAKER
EXISTING 2X2 GRID
SPRINKLER HEAD
WAP INTERNET
DUPLEX OUTLET
HVAC VENT
WAP S
S
E
CM
E
CM
TYP
2 2
TYP
L-
B O
A R
D R
O O
M R
EN
O
VA
TI
O N
N
EW
C
EI
LI
N
G P
LA
N
REVISIONS
DATE:
RCP-2
06/03/2025
WILLIAM GREEN
BUILDING
30 W. SPRING STREET
COLUMBUS, OH 43215
NUM. DATE
DRAWN BY: HG
LEGEND
EXISTING WALL
NEW WALL
EXISTING DOOR
CASEWORK
CODED NOTES
NEW 2x2 TILE SPEAKER, TYP OF (8)
REPLACE CEILING TILE WHERE
SPEAKER WAS REMOVED ENTIRELY
GENERAL NOTES
1. RE-USE EXISTING WIRING FOR
SPEAKERS, IF APPLICABLE. PULL
ANY UN-USED WIRES BACK TO
THE NEAREST JUNCTION BOX.
2x4 FIXTURE
DOWNLIGHT
2x2 DIFFUSER
S SPEAKER
EXISTING 2X2 GRID
SPRINKLER HEAD
WAP INTERNET
DUPLEX OUTLET
HVAC VENT
2x2 SPEAKER TILE
| Sheets and Views |
| 25-0602_L2 Board Room AV-COVER SHEET |
| 25-0602_L2 Board Room AV-E-1 |
| 25-0602_L2 Board Room AV-E-2 |
| 25-0602_L2 Board Room AV-RCP-1 |
| 25-0602_L2 Board Room AV-RCP-2 |
File details come from the government source that posted it. Updated .