This is a request for quote for local voice and data circuits. The solicitation requires quotes for all circuits listed in an attached statement of work for Aberdeen Proving Ground, Maryland. Quotes are due by the specified date and time and must come from facilities-based incumbent or competitive local exchange carriers certified to provide services in Maryland. The award will be made on an all-or-none basis to the responsible offeror with the most advantageous offer considering price and technical capability, past performance, and price factors. The performance period covers installation and five one-year ordering periods. Pricing must be held firm for 90 days and include all applicable taxes. The contractor must provide the services and meet all requirements described in the attached statement of work, including quantities and locations of circuits, features, administration, and regulations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 24Q0003 Price Quotation.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work
1.0 Scope. This Statement of Work (SOW) requires a Contractor to provide local exchange access services, analog and digital access transport services, and an inter/intra-Local Access Transport Area (LATA) interconnect functions. The Contractor shall provide all transmission facilities, equipment, materials, maintenance, test equipment, and design needed to perform and provide local access and transport services to designated demarcation point and destinations specified in Appendix 10. Access to the local exchange shall include operator assistance, directory assistance, and emergency E911 services. These services shall be limited to official Government services and shall not include any unofficial services such as residential or business services for non-Government entities or contractors.
2.0 Documents. The documents referenced in this SOW are intended to be commercial and industrial references for the purpose of developing a baseline of performance and some measure of quality for the local exchange access, data and transport services and functions. The contractor must obtain and follow all the latest revision(s) and/or addition(s) to the referenced documents and/or all other applicable regulations.
2.1 Competitive IntraLATA Technologies, Interface, and Services Reference Manuals. Copies of the documents listed under Paragraph 2.1 and supplemental paragraphs may be purchased from Ericsson at the following website https://telecom-info.njdepot.ericsson.net/site-cgi/ido/docs2.pl?ID=&page=home .
2.1.1 Functional Requirements (Common Sections)
| SR-3065 | LSSGR Guide |
| GR-505 | Call Processing |
GR-1364 Switch Processing Time GRs, Section 5.6
| GR-506 | Signaling for Analog Interfaces |
| GR-606 | Common Channel Signaling |
| GR-317 | Switching System GRs for Call Control Using ISDN User Part (ISDNUP) |
| GR-507 | Transmission |
| GR-508 | Automatic Message Accounting (AMA) |
GR-2932 Database Functionalities GR-478 Measurements and Data Generation GR-2963 OTGR Sec 2.2 Network Element Configuration Mgmt - Software Mgmt
| GR-510 | System Interfaces |
| GR-782 | SONET Digital Switch Trunk Interface Criteria |
| GR-518 | Synchronization |
| GR-511 | Service Standards |
| GR-512 | Reliability |
| GR-513 | Power |
| GR-63 | NEBS Requirements: Physical Protection |
GR-1089 Electromagnetic Compatibility and Electrical Safety - Generic Criteria for Network Telecommunications Equipment
| GR-477 | Network Traffic Management |
| GR-517 | Traffic Capacity and Environment |
| GR-815 | GRs for Network Element/Network System (NE/Ns) Security |
| GR-454 | Generic Requirements for Supplier-Provided Documentation |
| GR-839 | Generic Requirements for Supplier-Provided Training |
| GR-840 | Supplier Support Generic Requirements |
| GR-540 | Tandem Supplement |
2.1.2 Residence and Business Customer Features (FSD 00 and 01 Series)
| GR-520 | Features Common to Residence and Business Customers I |
| GR-219 | CLASS Feature: Distinctive Ringing/Call Waiting |
| GR-560 | Individual Line |
| GR-561 | Two-Party Line |
| GR-562 | Manual Line Features |
| GR-563 | Denied Termination |
| GR-564 | Code Restriction and Diversion |
| GR-565 | Voice/Data Protection |
| GR-218 | CLASS Feature: Selective Call Rejection |
| GR-568 | Series Completion |
| GR-569 | Multiline Hunt Service |
| GR-31 | CLASS Feature: Calling Number Delivery |
| GR-216 | CLASS Feature: Customer Originated Trace |
| GR-391 | CLASS Feature: Calling Identity Delivery Blocking Features |
| GR-567 | CLASS Feature: Anonymous Call Rejection |
GR-1188 CLASS Feature: Calling Name Delivery Generic Requirements
| GR-575 | CLASS Feature: Calling Identity Delivery on Call Waiting |
| GR-570 | Speed Calling |
| GR-571 | Call Waiting |
| GR-572 | Cancel Call Waiting |
| GR-573 | Business Group Call Waiting |
| GR-416 | CLASS Feature: Call Waiting Deluxe |
GR-1517 CLASS Feature: Outside Calling Area Alerting
| GR-574 | Business Group Automatic Callback |
| GR-215 | CLASS Feature: Automatic Callback |
GR-2948 Prompted Automatic Callback
| GR-227 | CLASS Feature: Automatic Recall |
| GR-577 | Three-Way Calling |
| GR-578 | Usage-Sensitive Three-Way Calling |
| GR-579 | Add-On Transfer and Conference Calling Features |
| GR-580 | Call Forwarding Variable |
| GR-581 | Remote Call Forwarding |
| GR-217 | CLASS Feature: Selective Call Forwarding |
| GR-586 | Call Forwarding Subfeatures |
| GR-588 | Customer Premises Message Registers |
GR-1401 Visual Message Waiting Indicator Generic Requirements GR-1512 Call Screening GR-3006 Class Feature: Audible Voice Identity Delivery GR-1520 Ring Control GR-2913 Generic Requirements for Call Park GR-590 Call Pickup Features
2.1.3 Private Facility Features (FSD 02 Series)
| GR-600 | Private Facility Access |
| GR-601 | Outward Wide Area Telecommunications Service |
| GR-602 | Customer Control |
| GR-603 | Outgoing Facility Group Queuing |
| GR-604 | Automatic Flexible Routing |
| GR-605 | Auth. Codes for AFR & Account Codes for Basic Business Group & AFR |
| GR-610 | Message Detail Recording (MDR) |
| GR-615 | GRs for Message Detail Recording (MDR) Access Interfaces |
| GR-621 | Traffic Data Provision Features |
| GR-32 | CLASS Feature: Bulk Calling Line Identification |
2.1.4 Customer Access Interfaces (FSD 04 and 05 Series)
| GR-524 | Attendant & Customer Switching System Features & Customer Interface |
| GR-30 | Voiceband Data Transmission Interface |
GR-1273 ADSI SPCS/Server Generic Requirements GR-1193 GRs for a Dedicated Data Link Interface bet.an End Office SPCS and CPE GR-283 Simplified Message Desk Interface (SMDI)
2.1.5 Public Telecommunications Features (FSD 10 Series)
GR-528 Public Telecommunications Service
2.1.6 Public Safety Features (FSD 15 Series)
GR-529 Public Safety GR-2931 High Probability of Completion Network Capability GR-2973 Lawful Access Feature: Switching Generic Requirements
2.1.7 Loop Capabilities (FSD 20-02 Series)
| GR-666 | Universal Pair Gain Systems |
| GR-672 | Bridge Services on an IDLC System |
2.1.8 Tone and Announcement Systems (FSD 20-06 Series)
| GR-674 | Special Information Tones |
| GR-675 | Expanded Announcement System |
2.1.9 Reverting Call Service (FSD 20-10 Series)
GR-677 Reverting Service
2.1.10 Nail-Up Circuits (FSD 20-16 Series)
GR-679 Nail-Up of Non-Switched Circuits on a Local Switch
2.1.11 Local Exchange Access Interfaces (FSD 20-24 Series)
| GR-690 | Exchange Access Interconnection |
| GR-691 | Facility/Service Selective Dialing Switching and Signaling Requirements |
| GR-692 | Exchange Access Operator Services System Signaling |
| GR-693 | Presubscription Indication |
| GR-695 | Integrated Multiple Access Switched Services |
| GR-697 | Feature Group A |
| GR-698 | Feature Group B |
2.1.12 Interoffice Features (FSD 25 Series)
GR-1083 Generic Requirements for Exchange Access AMA GR-1504 Generic Requirements for Wireless Service Provider AMA
| GR-394 | Switching System GRs for ICI Using The ISDN User Part (ISDNUP) |
| GR-531 | Interoffice |
2.1.13 Call Processing Features (FSD 30 Series)
| GR-532 | Call Processing Features |
| GR-220 | CLASS Feature: Screening List Editing |
GR-1436 CLASS Feature: Visual Screening List Editing GR-1251 CLASS Feature: Numbering Plan Area Split Management GR-2857 RTPFR: Generic Requirements for the Signaling System 7 (SS7) Release to Pivot (RTP) Phase I Network Capability GR-2970 Service Provider Identification Capability Specification
2.1.14 Database Services (FSD 31 Series)
GR-533 Database Services - Service Switching Points
2.1.15 Data Services (FSD 32 Series)
GR-534 Public Switched Digital Service
2.1.16 Test Arrangements (FSD 40 Series)
GR-536 Trunk, Line, and Special Service Circuit Test
2.1.17 Administration Features (FSD 45 Series)
| GR-730 | Provisioning-Driven Memory Administration (PDMA) |
| GR-738 | Local Point-to-Point Data Collection |
| TR-740 | Stored Program Control System/Operations System (SPCS/OS) - Network Data Collection Operations System (NDC OS) Interface |
| GR-741 | Network Administration Center (NAC) Input/Output (I/O) Channel |
| GR-745 | Service Specific Call Gapping |
| TR-746 | Stored Program Control System/Operations System (SPCS/OS) - Network Traffic Management Operations System (NTM OS) Interface via a Network Data Collection Operations System (NDC OS) |
| GR-747 | An Alternative Implementation of an SPCS to NTM OS Interface via an NDC OS |
2.1.18 Other LSSGR References.
| TR-NWT-000682 | Automatic Number Identification (ANI) and Operator Number |
| Identification (ONI) FSD 20-20-000 | |
| TR-TSY-000685 | Flexible ANI Information Digit Assignment FSD 20-20-0100 |
| GR-853 | ISDN Call Forwarding |
| TR-TSY-000854 | ISDN Call Pickup |
| TR-TSY-000855 | ISDN Automatic Callback |
| TR-TSY-000859 | ISDN Multiline Hunt Group |
| TR-TSY-00060 | ISDN Calling Number Identification (CNI) Services |
| GR-1188 | ISDN Call Name Delivery |
| TR-NWT-00119 | ISDN Automatic Recall |
| GR-1242 | ISDN Selective Call Rejection |
| GR-1326 | ISDN Calling Name Identification |
| TR-NWT-001187 | ISDN Calling Number Identification Services for PRI |
| GR-1367-CORE | ISDN Calling Name Identification for PRI |
| TR-NWT-000335 | Voice Grade Special Access Service Transmission Parameter Limits |
| and Interface Combinations offers by LEC to Customer | |
| GR-303 | Integrated Digital Loop Carrier Generic Requirements, Objectives, |
| and Interface | |
| GR-268 | ISDN Access Call Control Switching And Signaling Requirements |
| TA-TSY-000041 | Characterization of Subscriber Loop for Voice and ISDN Services |
| TR-NWT-000393 | Generic Requirements for ISDN Basic Access Digital Subscriber |
| Lines | |
| TR-NWT-000397 | ISDN Basic Access Transport System Requirement |
| TR-TSY-000752 | ISDN Primary Rate Access Transport System |
| GR-253 | Synchronous Optical Network (SONET) Transport Systems: |
| Common Generic Criteria | |
| GR-496 | SONET Add-Drop Multiplex Equipment |
| GR-2842 | ATM Service Access Multiplexer Generic Requirements |
| TR-TSY-000009 | Asynchronous Digital Multiplexes, Requirements and Objectives |
2.1.19 Other Reference Manuals.
ANSI T1X1.590-113, Synchronous Optical Network (SONET): Operations, Administration, Maintenance, and Provisioning.
ANSI T1.105-1991, Digital Hierarchy - Optical Interface Rates and Format Specifications.
ANSI T1.P64-199x and T1P1.3/92-002R2, Digital Processing of Video Signals - Video Coder/Decoder for Audiovisual Services at 56 to 1536 Kbps, T1/LB-255, T1Y1/90-077.
BELLCORE TR-TSY-000020, General requirements for Optical Fiber and Optical Fiber Cable, Issue 9.
BELLCORE GR-2845-CORE, Issue 1, Generic Requirements for ATM Network and Element Management Layers.
BELLCORE GR-1111-CORE, Issue 1, B-ISDN Access Signaling Generic Requirements.
BELLCORE GR-1113-CORE, Issue 1, ATM and ATM Adapter Layer (AAL) Protocols.
BELLCORE GR-1118-CORE, Issue 1, Broadband Interswitching System Interface Generic Requirements.
BELLCORE TR-NWT-001112, Broadband ISDN User to Network Interface and Network Node Interface Physical Layer Generic Criteria.
2.1.20 Safety and Health Standards. The OSHA documents may be obtained from the Superintendent of Documents, US Government Printing Office, Washington DC, 20402. ANSI and NFPA documents may be obtained from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
OSHA CFR 29 Occupational Safety and Health Standards Part 1910
OSHA CFR 29 Hazardous Waste Operation & Emergency Response Part 1910.120 OSHA CFR 29 Confined Spaces Part 1910.146
OSHA CFR 29 Telecommunication Part 1910.268
| OSHA CFR 29 | Asbestos, Tremolite, Anthophyllite and Actinolite |
| Part 1910.1001 | (Labor) |
OSHA CFR 29 Hazard Communication Part 1910.1200 OSHA CFR 29 Excavation Part 1926, Subpart P (650,651 & 652
| OSHA CFR 29 | Asbestos, Tremolite, Anthopyllite, & Actinolite | |
| Part 1926.58 | (Construction) |
ANSI C2 National Electric Safety Code (NESC)
NFPA 70 National Electrical Code (NEC)
| EPA CFR Parts 261, | Hazardous Waste Generation & | |
| 262, & 263 | Transportation |
EPA Clean Air Act
| National Environmental | Code of Federal Regulations Parts |
| Protection Act, Title 40 | 1500 -1508 |
| DODI 5000-2, Part 6 | System Safety, Health Hazards & | |
| Environment Impact |
3.0 Requirements.
a. Appendix 10 identifies all services required, including characteristics, quantities and locations.
b. The Contracting Officer’s Representative (COR) is responsible for monitoring and accepting all services identified in Appendix 10. The Contractor shall coordinate with the COR before installing, removing or changing equipment.
c. The Government will provide rack space and electrical power for the installation of the Contractor’s transmission equipment. This rack space will be limited to two relay racks, 19 to 23 inches wide by 7 to 9 feet tall, if ceiling height permits at the designated demarcation. If additional rack space is required to support future Government requirements, the Contractor shall coordinate with the COR to determine if space is available.
d. The Contractor’s equipment shall be upgradeable or expandable to support changes in service requirements. To meet expansion requirements, the Contractor’s equipment shall be modularly expandable or reducible to permit growth or to migrate to higher or lower order services without requiring forklift upgrades.
3.1 Local Commercial Communications Services.
3.1.1 Installation and Cutover. The Contractor shall provide the Contracting Officer (KO) with an installation and cutover plan on the first day of the cut-over performance period (CLIN 0001). The Contractor shall not commence on-site installation and cutover until the Contractor receives notice that the Government has accepted the service installation and cutover plan. Installation and cutover shall be completed no later than 120 calendar days after Government acceptance of the cut-over plan. The Contractor will be responsible for issuing disconnect orders to the incumbent provider after successful activation and testing of each circuit.
3.1.2 Commercial Subscriber Lines & Exchange Access Trunks. Local exchange access, as applicable shall include commercial subscriber lines and off premise extensions, CENTREX, exchange access trunks and transport services.
3.1.2.1 Commercial Subscriber Lines. The Contractor shall provide subscriber lines as specified in Appendix 10. Local exchange access, as applicable, shall include commercial subscriber lines and foreign exchange lines.
3.1.2.2 Commercial Subscriber Line Basic Services. Basic services of a line, as a minimum, shall include the following:
· dial tone
· direct inward dialing
· direct outward dialing
· Dual Tone Multi-Frequency (DTMF) capability for local exchange and long distance access
· equal access
· call blocking for Numbering Area Plan (NPA) 900 and NPA 976
· Block Operator Assistance (0+ & 00+)
· E911/911 services in all cases and 311 services where available
· non-published directory number
· service disconnect with referral service of at least three (3) months after a customer’s number has been changed or disconnected
· block Directory Assistance Call Completion (DACC) and Directory Assistance.
· block third-party billing
· block 10-10 dialing
· block Collect Calls
· block Automatic Call Return Feature
3.1.2.3 Commercial Subscriber Line Additional Features. The Contractor shall make available to commercial subscribers additional line features as specified in Appendix 10. An additional feature may be an individual feature or a group of features.
3.1.2.4 CENTREX Features. CENTREX Basic Feature Package (CBFP) shall be as specified in Appendix 10. Minimum Centrex backups must be maintained for emergency E911 services to Defense Emergency Services (DES).
3.1.2.5 Subscriber Line Relocation. The Government will perform subscriber line relocation unless otherwise specified in the SOW. The Contractor shall perform database updates for address changes for emergency E911 service purposes when required by the SOW.
3.1.2.6 Exchange Access Trunks. The Contractor shall provide local exchange access service circuits for local trunks as specified in Appendix 10.
3.1.2.7 Exchange Access Trunks Basic Services. Basic services of an (local or foreign exchange) access trunk, as a minimum, shall include the following, as applicable:
· direct inward dialing
· direct outward dialing
· two-way dialing
· channelization of digital trunks (as specified by work order)
· trunk busy tones
· DTMF MF 2/6 and dial pulse address signaling
· access services
· block DACC
· trunk and/or trunk group establishment
· automatic trunk member selection (sequential, linear, most idle, etc.)
· automatic trunk group alternate route selection
· block third-party billing
· Access to 1-800 calling
· Access to Government Emergency Telephone System (GETS)
· Caller ID
3.1.3 Transport Services. The Contractor shall provide local exchange transport channel services as specified in Appendix 10. Local transport channel services include transport channel termination and transmission support, as applicable, for analog lines, ISDN lines, alarm circuits, data circuits up to 64 Kbps or aggregate N x 64 Kbps, Primary Rate ISDN, Broadband-ISDN, High Capacity Data Subscriber Line (HDSL), Digital Signal level 1 (DS-1), DS-3, Optical Carrier Signal level 1 (OC-1), OC-3, and may be expanded to OC-12, and OC-48.
3.1.4 Circuit Termination. Circuit termination at the Government installation includes the Main Distribution Frame (MDF) for analog signals and metallic cable pairs, DSX-1 patch and cross connect panel for T-1 circuits, DSX-3 for electrical T-3 circuits, fiber optic patch and cross connect panels for optical interface equipment such as the optical carrier or SONET systems, optical multiplexer equipment, and Cat 3/5 RJ-45 jack fields. Other wall-mounted, punch-down, terminal blocks are used for isolation and termination of Contractor metallic facilities. The Contractor shall ensure that all circuits are clearly tagged in a permanent manner with the circuit identification number or telephone number assigned to the circuit, and the work order number.
3.1.4.1 Analog and Low Data Rates. The Contractor shall terminate the analog and lower rate data circuits to the Contractor’s terminal blocks. The Government shall provide space for installation of Contractor’s blocks. All outside plant copper cables entering the demarcation location must be electrically protected (grounded, terminated on protector modules, etc.).
3.1.4.2 High Data Rates. The Contractor shall properly terminate digital circuits to the Contractor provided DSX-1, DSX-3, or fiber optic patch panel.
3.1.4.3 Circuit Testing. The Contractor shall test circuits after installation and provide test results to the COR in writing. The Contractor shall document the circuit characteristics in the Customer Service Records.
3.1.5 Local Exchange Access and Service Areas. The Contractor shall provide local services for both subscriber lines and trunks within the local calling areas. The local access service areas shall, as a minimum, include the areas/zones coverage as currently defined by the local service provider(s) and/or the applicable State Public Utilities Commission (PUC). The local and foreign exchange access service areas shall be, as a minimum, bounded by geographic city areas/zones and/or surrounding areas. The access areas shall not be limited by prefixes that may change. The local service areas/zones/boundaries shall not be reduced. If the contractor determines that the local/foreign exchange access service areas are different than defined, the Contractor shall coordinate with the COR and the KO for approval. When the Contractor provides services to a Government installation, the LATA boundary shall not be limited or restricted to a Contractor’s service area. Connection to intra-LATA exchange areas and with inter-LATA exchange carriers is an essential part of the local exchange access.
3.1.5.1 Long-Distance Access/Service. The contractor shall designate the primary interchange carrier (PIC) for all long-distance in accordance with the Letter of Agency (LOA) issued by the Contracting Officer as either NETWORX or the current long-distance provider for the Department of Defense as determined by DISA.
3.1.6 Number Portability. The Contractor shall provide number portability for commercial subscriber lines and local exchange direct-in-dial (DID) directory numbers. The consistent use of the same prefix exchange and directory numbers provides the Government installation with its commercial identity. The Contractor shall provide an additional block of DID directory numbers within the existing assigned NXX prefix exchanges to the installation until exhausted. The Government installation is also serviced by other Government switched networks, FTS 2001 and the Defense Switched Network (DSN). These networks provide DID trunks and are directly dependent on the mutually assigned DID numbers to terminate into stations on the installation. Local exchange number portability and DID number growth is a critical factor in the ability of a Government installation to support its personnel and its missions. The Contractor shall comply with the Federal Communications Commission (FCC) and the State Public Utility Commission (PUC) mandates for number portability.
3.1.7 Demarcation. The Government will designate the demarcation point (location) for Contractor equipment installation and termination of transport facilities. The typical location of the primary demarcation point is the Government Dial Central Office (DCO).
3.1.7.1 Circuit Extension. The Government may extend a service or circuit beyond the established demarcation to a Government termination point. When local exchange access requirements indicate the Contractor requires circuit extension, the Contractor shall provide circuit extension through circuit termination and/or Contractor owned/leased transport cable.
3.1.7.2 Government Cable. When Government cable is available, the Contractor shall provide circuit termination for a circuit extension. Circuit termination shall include transmission equipment, termination hardware, and circuit conditioning equipment required to extend a circuit to a user location.
3.1.7.3 Contractor Owned/Leased Transport Cable. When Government cable is not available, the Contractor shall provide the circuit transport.
3.1.8 Contractor Equipment and Cable Installation. The Contractor shall provide and install all transmission equipment and cables to provide services to the demarcations. The Contractor shall coordinate with the COR for equipment and cable installation. The Contractor shall install equipment and cables in accordance with all applicable safety codes. The Contractor shall be responsible for wiring and connecting to Government power connection points, ground master connection points, and termination frames for terminal blocks.
3.1.9 Restoration of Service and Maintenance. The Contractor shall provide a point of contact (POC) for the Government to report all service outages. The POC shall be available 24 hours a day, 7 days per week. The Government will classify outages as either “Catastrophic,” “Emergency,” “Serious,” or “Routine,” depending on the impact on Government services. The COR will notify the Contractor of the classification when reporting the outage. The Contractor shall respond to and correct service outages within the time limits specified. If the Contractor determines the restoration time frames cannot be met, the Contractor shall immediately notify the COR. The Contractor shall respond to the Government within one (1) hour of notification.
3.1.9.1 Catastrophic Outage. Restore service within four (4) hours from the time the Contractor responds to the Government’s notification.
3.1.9.2 Emergency Outage. Restore service within eight (8) hours from the time the Contractor responds to the Government’s notification.
3.1.9.3 Serious Outage. Restore service within twenty-four (24) hours from the time the Contractor responds to the Government’s notification.
3.1.9.4 Routine Outage. Restore service within two (2) calendar days from the time the Contractor responds to the Government’s notification.
3.1.10 Diversity/Diverse Routing. The Contractor shall provide diversity for local communications services as required in the Appendix 10. Diversity is primarily considered to be designed redundant paths, rings, etc., along with the electronic systems in the path that permit transport channels to reach their destination demarcation point in the local exchange without interruption in the event of the failure of one path.
3.1.11 Operator Assistance. The Contractor shall provide operator assistance for local exchange and access services, including, as a minimum but not limited to, subscriber line verification, barge-in, call extension, and assistance with other exchange access functions.
3.1.13 E911/311 Services. The Contractor shall provide access to enhanced 911 services, if available, through the local emergency services organization, to include transmission of all 911 and E911 ANI/ALI information to the applicable PSAP. The contractor shall update the Master Street Address Guide (MSAG) with updates provided periodically by the Government. All outgoing city trunks must provide Automatic Number Identification (ANI) of the caller to the local city enhanced 911 network in the proper format to enable Automatic Location Identification (ALI) to be properly retrieved by the primary and back-up enhanced 911 Public Safety Answering Points (PSAPs). Emergency service assistance shall be provided for the hearing impaired. The Contractor shall provide access to 911 or enhanced 911 services, where available, through the local city or county emergency services organization
3.2 Future Services. The Contractor shall provide future services as required by Appendix 10. After acceptance of a contract modification, the Contractor shall complete the installation or disconnection of services within the time frames defined below.
3.2.1 Emergency Services. The time frame is one calendar day.
3.2.2 Priority Services. The time frame is five calendar days.
3.2.3 Routine Services. The time frame is 10 calendar days.
3.2.4 Traffic Analysis. The Contractor shall perform traffic measurement and traffic analysis as required.
3.3 Customer and Communications Service Records. The Contractor shall be responsible for creating and updating the local service records. The local service records shall include customer service records and communications service records and shall be provided to the COR and/or the Contracting Officer upon request.
The Contractor shall update Customer and Communications service records not later than 10 working days after a service has been activated or deactivated.
3.4 Contract Management.
3.4.1 Meetings. The Contractor’s project manager shall be available Monday to Friday, between 7:00 a.m. to 5:00 p.m. local time, to meet the COR on-site for technical interchange discussions. The Contractor’s project manager shall have full authority to effect service changes requested by the Government.
3.4.2 Support. The Contractor shall assist the COR with testing and implementation of a new service circuit or expansion to existing circuits. The Contractor shall cooperate with the COR or other vendors that may be interconnecting with other related services. When expansion services entail Contractor support that requires additional equipment or testing to activate a circuit, the Contractor shall develop the installation and activation plans with the COR.
3.4.3 Point-of-Contact. The Contractor shall provide a 24-hour point-of-contact telephone number for the notification of telephone/circuit outages and services prior to service cutover.
3.5 Regulations and Policies. The Contractor shall follow all base regulations and policies regarding security, safety, and environmental, and federal, state and local regulations, as applicable.
3.5.1 Safety Training and Education. The Contractor must have a safety and health plan for the employees that complies with all applicable Federal, State, local and Army requirements.
3.5.2 Safety and Health. The Contractor shall meet with civil engineering, safety and bioenvironmental personnel before beginning work surveys in areas that may contain asbestos and/or other hazardous materials or may result in hazardous wastes. The Contractor shall follow Army procedures as outlined by personnel in these offices, including procedures for disposal of residue hazardous materials and empty hazardous materials containers.
3.5.3 Hazardous Material Reporting on Federal Installations. The Contractor is required to provide Material Safety Data Sheets (MSDS) on each hazardous material/compound that will be used in performing this contract. The Contractor will provide the MSDS to the federal facilities Environmental Management Office for approval before using any hazardous materials (paints, solvents, cleaners, encapsulating compounds, etc.). Hazardous materials are not permitted on any federal facility until the local Environmental Management Office has approved their use. There are no exceptions to this requirement, and the Contractor shall ensure compliance whether the Contractor or a subcontractor performs the work.
3.5.4 Ozone Depletion. No ozone-depleting chemicals or compounds shall be used during the performance of work.
3.5.5 Work Clearance Request. The Contractor shall obtain clearance from the Directorate of Engineering and Housing (DEH) or the Department of Public Works (DPW) before trenching, digging, or modifying a facility. The Contractor shall ensure that all the following requirements are met. All open trenches and open holes must be properly protected by use of barricades and warning signs. Trenches, pits, and holes that employees have to enter must be protected from excavated materials or equipment that could fall or roll into the excavated area. Therefore, all excavated materials and equipment must be a minimum of two feet from the edge of the trench, pit, or hole. Shoring will not be required for trenches, pits and holes less than 5 feet deep. Exceptions will depend on the type of soil and the amount of rain in the area (Ref OSHA 1926 Appendix A to Subpart P, Soil Classification). Employee protection for working in a trench, pit, or hole can also be accomplished by sloping and/or benching (Ref OSHA 1926.652 for configurations). Excavations that are next to sidewalks and roadways shall be guarded by barricades with flashing lights. Excavations that go under sidewalks shall be guarded with handrails on both sides and supported to keep from collapsing. Excavations under roadways shall have support structures installed to support the roadway. Support structures will be approved by DEH or DPW, as applicable. All excavated areas shall be back filled and/or restored to the original condition when the work has been completed. Confined spaces entry (i.e., entering manholes, tunnels, and unvented vaults) shall be coordinated with the local safety and health offices prior to entry. Confined spaces atmospheric testing shall be accomplished by testing oxygen levels, toxic levels, and combustible levels consistent with local base procedures for entering and working in confined spaces. If work is being performed in a confined space, then forced air ventilation is required. Under no circumstances shall the Contractor handle, transport, or dispose of hazardous waste materials. This is solely the facility owner’s responsibility.
3.5.6 Accident/Incident Reporting and Investigation. The Contractor shall record and report to the COR all available facts relating to each instance of accidental damage to Government property or injury to either Contractor or Government personnel. The Contractor shall secure the accident scene and/or wreckage until released by the COR or contracting officer. The Contractor shall cooperate fully with any investigation and assist the investigators in any way necessary.
3.5.7 Section 508 Compliance. Services within the Statement of Work are exempt under FAR 39.204(d).
APPENDIX 10
REQUIRED LOCAL COMMERCIAL COMMUNICATIONS SERVICES AT CUTOVER
10.0 Local services required from the Contractor, are initial installation and cutover service requirements for the Government under the scope of this contract. The Contractor shall provide the following baseline of local commercial communications services at cutover. The quantity of these requirements will be incorporated into the Pricing Schedule.
· Verizon is currently providing the local exchange access services at the Aberdeen Proving Ground (Aberdeen and Edgewood Areas), Aberdeen Proving Ground, Maryland.
· The Aberdeen Area of Aberdeen Proving Ground is serviced by an AVAYA S8720 and an AVAYA S8710 switching system with software release Communication Manager 4.02. The demarcation points in the Aberdeen Area for all commercial circuits (except where noted in the table below) is Building 311 at 6851 Civil Road, Aberdeen Proving Ground, Maryland 21005.
· The Edgewood Area of Aberdeen Proving Ground is serviced by an AVAYA S8720 switching system with software release Communication Manager 4.02. The demarcation points in the Edgewood Area for all commercial circuits (except where noted in the table below) is Building E5103 at 8276 Rouse Road, Aberdeen Proving Ground, Maryland 21010.
· The official primary inter-LATA and intra-LATA service provider for local and long-distance service is NETWORX. The Primary Interchange Carrier (PIC) will be NETWORX for all services under this contract.
10.1 Direct-In-Dial Directory Numbers. Aberdeen Area:
| NPA- NXX-XXXX |
| DID Directory Numbers |
| 410-278-0000 to 0799 |
| 800 |
| 410-278-0820 to 8019 |
| 7200 |
| 410-278-8500 to 8859 |
| 360 |
| 410-278-8880 to 9999 |
| 1120 |
| 410-306-0000 to 4999 |
| 5000 |
| 410-306-8780 to 8799 |
| 20 |
| 410-306-8700 thru 8719 TLI 410-306-8845 |
| 20 |
| 443-395-0000 to 9999 |
| 10000 |
| 443-861-0000 to 9999 |
| 10000 |
| TOTAL |
| 34,520 |
10.1.1 Direct-In-Dial Directory Numbers. Edgewood Area:
| NPA- NXX-XXXX |
| DID Directory Numbers |
| 410-436-0000 to 9999 |
| 10,000 |
| 410-417-0000 to 4999 |
| 5,000 |
| TOTAL |
| 15,000 |
10.2 Commercial Subscriber Lines.
10.2.1 Commercial Subscriber Lines, Aberdeen Area.
| # |
| NPA-NXX-XXXX |
| Type |
| Features |
| Demarcation |
| Description |
410-272-8842
Analog, Loop, 2- wire
Voice
| Service address 500 Edgewood Rd |
| DSHE – Bldg E5183 |
(Environmental Hotline – phone forwarded to E5183 on 410-417-2035)
410-272-0424 Analog, Loop, 2- wire
Voice
| Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005 |
| ATC – Bldg 358 |
Lanyard Road
410-272-1335 Analog, Loop, 2- wire
Modem, hunting, Bldg 400, Bsmt-Range Control - Mulberry Point Road, Aberdeen Proving Ground, MD 21005 ATC, Mulberry Point, Aberdeen Proving Ground
410-272-1474 Analog, Loop, 2-wire
Modem Mulberry Point Road, Aberdeen Proving Ground, MD 21005
ATC, Mulberry Point, Aberdeen Proving Ground
410-272-1339
| Analog, Loop, 2- wire |
| Modem In hunt group behind 410-273-1335 |
| Bldg 400, Bsmt-Range Control - Mulberry Point Road, Aberdeen Proving |
ATC, Mulberry Point, Aberdeen Proving Ground
410-272-1471
| Analog, Loop, 2- wire |
| Modem In hunt group behind 410-273-1335 |
| Bldg 400, Bsmt-Range Control - Mulberry Point Road, Aberdeen Proving |
ATC, Mulberry Point, Aberdeen Proving Ground
410-272-1390
| Analog, Loop, 2- wire |
| Modem In hunt group behind 410-273-1335 |
| Bldg 400, Bsmt-Range Control - Mulberry Point Road, Aberdeen Proving |
ATC, Mulberry Point, Aberdeen Proving Ground
410-272-1688
Dialup Modem, (Noise Monitoring Circuit)
| Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005 |
| ATC - Tower at Mulberry Point, near Bldg 646 (GPS |
Coordinates:
39.26.44N / 76.06.10W)
410-272-3266 Analog, Loop, 2- wire
Voice
| Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005 |
| ATC – Trailer Park (#103) |
410-272-6606 Analog, Loop, 2- wire
Voice
| Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005 |
| ATC - Bldg 400, Rm F-1 (SAD: 399 |
Mulberry Point)
410-273-0256 Analog, Loop, 2- wire
Voice Bldg 3400 - 6444 Aberdeen Blvd, Aberdeen Proving Ground, MD 21005 DECA – Bldg 3400 (Commissary)
410-273-0482 Analog, Loop, 2- wire
Voice Bldg 3400 - 6444 Aberdeen Blvd, Aberdeen Proving Ground, MD 21005 DECA – Bldg 3400 (Commissary)
410-273-6443 Analog, Loop, 2- wire
Dialup Modem
| Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005 |
| RNEC – Bldg 311 |
410-273-7529
Dialup Modem, (Noise Monitoring Circuit)
| Pole located at Water Treatment Plant, 411 South Old Post Road, Aberdeen, MD |
| ATC – Noise Monitoring on Pole at Water Treatment Plant, 411 S. Old |
Post Road, Aberdeen, MD
410-273-7782
| Dialup Modem, (Noise Monitoring Circuit) |
| Pole located at Michaelsville Rd Perryman, MD; GPS Coordinates |
39.28.03 North/76.12.15
West ATC - Perryman, MD
410-275-1287
| Dialup Modem (Noise Monitoring Circuit) |
| Pole located at Grove Neck Rd/New, Hampshire Ave, Grove Point, MD; GPS coordinates 39.23.46 |
North/76.02.14 West ATC - Grove Point, MD
410-275-2384
| Dialup Modem, (Noise Monitoring Circuit) |
| Pole located at 4th St & Beachwood Ave., Crystal Beach, MD. GPS |
coordinates 39.26.41 North/75.58.19 West ATC - Crystal Beach, MD
410-278-5201 Analog, Loop, 2- wire
| Voice Caller ID |
| Bldg 311 – 6851 Civil |
Road, Aberdeen Proving Ground, MD 21005 RNEC – Bldg 311, Main Installation Number (ADAS)
410-287-8283
| Dialup Modem, (Noise Monitoring Circuit) |
| 150 Bayview Blvd, Red Point Rd., Charlestown, MD; GPS coordinates |
39.31.32 North/75.58.49
ATC - Charlestown, MD
410-287-8401
| Dialup Modem, (Noise Monitoring Circuit) |
| Pole located at Water St., Conestoga, Charlestown, MD; GPS coordinates |
39.34.14 North/75.58.23
ATC - Charlestown, MD
410-335-1960
| Analog, Loop, 2- wire |
| Dialup Modem, (Noise |
Monitoring Circuit) Pole located at Bay Drive, Middle River MD; GPS coordinates 39.18.05 North/76.22.35 West ATC – Middle River, MD
410-348-2211
| Analog, Loop, 2- wire |
| Dialup Modem, (Noise |
Monitoring Circuit) Pole located at Idlewhile Ave., Betterton, MD; GPS coordinates 39.22.10 North/76.04.02 West ATC - Betterton, MD
410-457-4159
No address available Deer Creek Water Station, Darlington, MD 21034; GPS coordinates Lat 39°37'02.8", long 76°11'30.7" per Google DPW - Darlington, MD
410-457-4307
Deer Creek Pumping Station, No address available Darlington Rd, Darlington, MD 21034; GPS coordinates Lat 39°37'02.8", long
ATC - Darlington, MD
410-457-4980
Deer Creek Pumping Station, No address available Darlington Rd, Darlington, MD 21034; GPS coordinates Lat 39°37'02.8", long
ATC - Darlington, MD *USGS Deer Creek Flow
410-676-1631
| Dialup Modem, (Noise Monitoring Circuit) |
| Pole located at Harford Sq Drive, Edgewood, MD 21040; GPS coordinates |
39.25.11 North/76.19.16
ATC - Edgewood, MD
410-676-6443
| Analog, Loop, 2- wire |
| Voice, (Noise Monitoring Circuit) |
| Pole located at Long Bar Harbor Rd, Abingdon, MD; |
GPS coordinates 39.27.22 North/76.15.00 West ATC - Abingdon, MD
410-734-5950 Analog, Loop, 2- wire
Voice
| 775 Priestford Rd., Bldg 10301, Churchville, MD. |
| ATC – Bldg 10301 |
410-734-6511 Analog, Loop, 2-wire
Voice Churchville Test Area, 775 Priestford Rd, Bldg 10301, Churchville, MD ATC – Bldg 10301
410-734-7040 Analog, Loop, 2- wire
Voice
| Bldg 10301, 775 Priestford Rd, Churchville, MD |
| ATC – Bldg 10301 |
410-734-7647 Analog, Loop, 2- wire
Voice
| Churchville Test Area, 775 Priestford Rd, Bldg 10301, Churchville, MD |
| ATC – Bldg 10301 |
410-778-9023
| Analog, Loop, 2- wire |
| Dialup Modem, (Noise Monitoring |
Circuit) Pole 21 located at Elm St. Tolchester, MD; GPS coordinates 39.13.34 North/76.13.56 West ATC Tolchester, MD
410-778-9024
| Analog, Loop, 2- wire |
| Dialup Modem, (Noise |
Monitoring Circuit) Pole located at Handy Point Rd., Stoops Point, MD;
GPS coordinates 39.16.47 North/76.11.59 West ATC - Stoops Point, MD
410-778-9025
| Analog, Loop, 2- wire |
| Dialup Modem, (Noise |
Monitoring Circuit) Pole located at Smithfield Rd., Worton Point, MD;
GPS coordinates 39.18.08 North/76.11.07 West ATC - Worton Point, MD
410-810-0350
| Analog, Loop, 2- wire |
| Dialup Modem, (Noise |
Monitoring Circuit) Pole located at Howell Pt Rd., Howell Point, MD;
GPS coordinates 39.21.38 North/76.06.59 West ATC - Howell Point, MD
410-734-7042 Analog, Loop, 2- wire
Voice 775 Priestford Road , Bldg 10301, Churchville, Md 21028 ATC – Bldg 10301
410-734-5951 Analog, Loop, 2-wire
Voice
| 775 Priestford Rd., Bldg 10301, Churchville, MD. |
| ATC – Bldg 10301 |
410-734-5952 Analog, Loop, 2-wire
Voice
| 775 Priestford Rd., Bldg 10301, Churchville, MD. |
| ATC – Bldg 10301 |
410-273-6193 Analog, Loop, 2- wire
Voice Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005 DES - Bldg 2200, Dispatch
410-273-6196 Analog, Loop, 2- wire
Voice
| Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005 |
| DPW - Bldg 4304 |
410-939-5258
| Voice, (Noise Monitoring Circuit) |
| Pole located Concord / Alliance St., Havre de Grace, MD; GPS coordinates 39.32.28 |
North/76.05.06 West ATC - Havre de Grace, MD
410-734-6125
Analog
| Voice (Monitoring) |
| 775 Priestford Road , Bldg 10301, Churchville, Md |
DES – Churchville, MD
410-734-6239
Analog
| Voice (Monitoring) |
| 775 Priestford Road , Bldg 10301, Churchville, Md |
DES – Churchville, MD
410-273-8975
Analog
Voice (POTS) Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005 DES – Bldg 2478 ( E911 Center)
10.2.2 Commercial Subscriber Lines, Edgewood Area.
| # |
| NPA-NXX-XXXX |
| Type |
| Features |
| Demarcation |
| Description |
410-676-1364 Analog, Loop, 2-wire
Voice Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010 ECBC – Bldg E3401
410-676-1365 Analog, Loop, 2- wire
Voice Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010 ECBC – Bldg E3401
410-612-5981 Analog, Loop, 2- wire
Voice
| Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010 |
| ECBC – Bldg E3401 |
410-612-5982 Analog, Loop, 2-wire
Voice Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010 ECBC – Bldg E3401
410-612-5983 Analog, Loop, 2- wire
Voice Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010 ECBC – Bldg E3401
410-612-0577
1 ARMY CHEMICAL CTR GUNPOWDER,
Aberdeen Proving Ground, MD 21010 (Edgewood Area) Aberdeen Proving Ground, MD (Edgewood Area)
410-612-0656 Analog, Loop, 2- wire
Voice
1 ARMY CHEMICAL CTR GUNPOWDER,
Aberdeen Proving Ground, MD (Edgewood)
410-612-0923
1 ARMY CHEMICAL CTR GUNPOWDER,
Aberdeen Proving Ground, MD 21010 (Edgewood Area) Aberdeen Proving Ground, MD (Edgewood Area)
410-612-0951
1 ARMY CHEMICAL CTR GUNPOWDER,
Aberdeen Proving Ground, MD (Edgewood Area)
410-676-0960 Analog, Loop, 2-wire
Voice B ldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010 DES – Bldg E5180 (APGFD Commercial 911)
410-676-1246
1 ARMY CHEMICAL CTR GUNPOWDER,
Aberdeen Proving Ground, MD 21010 (Edgewood Area) Aberdeen Proving Ground, MD (Edgewood Area)
410-671-6147 Analog, Loop, 2-wire
Voice Bldg E6110 – 1126 Edgewood Road, Edgewood, MD 21040 DPW – Bldg E6110 (Van Bibber)
410-676-0143 Analog, Loop, 2-wire
Voice (Modem) Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010 RNEC – Bldg E5103 (Remote Dial Up)
410-676-0876 Analog, Loop, 2- wire
Voice (Modem) Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010 RNEC – Bldg E5103 (Remote Dial Up)
410-671-7231 Analog, Loop, 2- wire
Fax Bldg E6110 – 1126 Edgewood Road, Edgewood, MD 21040 DPW – Bldg E6110 (Van Bibber)
410-612-8088
2-wire
| Water Level Monitoring Circuit |
| Bldg E6110 – 1126 |
Edgewood Road, Edgewood, MD 21040 DPW – Bldg E6110 (Van Bibber), Otter Point Creek US Geological Survey
410-616-6106
Analog
Voice (POTS)
| Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010 |
| DES – E4224, E911 |
Center
10.2.3 E911 CAMA /ALI AND 311 Trunk/Lines.
| # |
| Circuit ID |
| Type |
| Rate |
| Demarcation |
| Description |
CAMA - 1: 91.EMNT.410.91
1.2720
Analog Circuits
Voice Grade data circuit
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
DES – E4224, E911
Center. APG MD EMS
APG MD-VRZN ABDN C0-VRZN
Pikesville / Ellicott City MD- MD PSAP
CAMA - 2: 91.EMNT.410.91
1.2721
DES – E4224, E911
Center. APG MD EMS
CAMA - 3: 91.EMNT.410.91
1.2722
DES – E4224, E911
Center. APG MD EMS
CAMA- 4: 91.EMNT.410.91
1.2723
DES – E4224, E911
Center. APG MD EMS
ALI - 1: 91.DRYZ.200205. MD
DES – E4224, E911
Center. APG MD EMS
APG MD-VRZN ABDN C0-VRZN
ALISA Fairland MD/ Freehold NJ- MD PSAP
ALI - 2: 91.DRYZ.100.773
.MD
DES – E4224, E911
Center. APG MD EMS
ALISA Fairland MD/ Freehold NJ- MD PSAP
CAMA-1
Analog Circuit
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010 DES – E4224, E911 Center. APG MD EMS APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP
CAMA-2
DES – E4224, E911 Center. APG MD EMS APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP
CAMA-4
DES – E4224, E911 Center. APG MD EMS APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP
CAMA-4
DES – E4224, E911 Center. APG MD EMS APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP
ALI-1
DES – E4224, E911 Center. APG MD EMS APG MD-VRZN ABDN C0-VRZN ALISA Fairland MD/ Freehold NJ- MD PSAP
ALI-2
DES – E4224, E911 Center. APG MD EMS APG MD-VRZN ABDN C0-VRZN ALISA Fairland MD/ Freehold NJ- MD PSAP
10.3 Local Exchange Digital (ISDN PRI) Trunks. Estimated usage 40,100 minutes per PRI. All B-Channels are 2 Way. All PRIs must provide caller ID.
10.3.1 ISDN PRI Trunks, Aberdeen Area.
| # |
| ISDN PRI Circuit ID |
| D- |
Channel
| B-Channels & Signaling |
| Demarcation |
| 1 |
| 38IPZD.103158.1 MD |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 2 |
| 38IPZD.103158.-02 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 3 |
| 38IPZD.103158.-03 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 4 |
| 38IPZD.103158.-04 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 5 |
| 38IPZD. 103158.-05 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 6 |
| 38IPZD. 103158.-06 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 7 |
| 38IPZD. 103158.-07 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 8 |
| 38IPZD. 103158.-08 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 9 |
| 38IPZD. 103158.09 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 10 |
| 38IPZD.103158.-10. |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 11 |
| 38IPZD. 103158.-11 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 12 |
| 38IPZD. 103158.-12 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 13 |
| 38IPZD. 103158.-13 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 14 |
| 38IPZD. 103158.-14 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 15 |
| 38IPZD. 103158.-15 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 16 |
| 38IPZD. 103158.-16 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
| 17 |
| 38IPZD.103412.1.MD TLI 410-306-8845 |
| 1 |
| 23, Caller ID, DTMF, |
Loop Start
LAB LCMC CECOM 6010 APG MD
10.3.2. ISDN PRI Trunks, Edgewood Area.
| # |
| ISDN PRI Circuit ID |
| D- |
Channel
| B Channels & Signaling |
| Demarcation |
| 1 |
| 38IPZD330506.001 |
| 1 |
| 23, DTMF, Caller ID, |
Hunting, Loop Start E5103, Bond Road APG
| 2 |
| 38IPZD330506.002 |
| 1 |
| 23, DTMF, Caller ID, |
Hunting, Loop Start E5103, Bond Road APG
| 3 |
| 38IPZD330506.003 |
| 1 |
| 23, DTMF, Caller ID, |
Hunting, Loop Start E5103, Bond Road APG
| 4 |
| 38IPZD330506.004 |
| 1 |
| 23, DTMF, Caller ID, |
Hunting, Loop Start E5103, Bond Road APG
| 5 |
| 38IPZD330506.005 |
| 1 |
| 23, DTMF, Caller ID, |
Hunting, Loop Start E5103, Bond Road APG
| 6 |
| 38IPZD330506.006 |
| 1 |
| 23, DTMF, Caller ID, |
Hunting, Loop Start E5103, Bond Road APG
10.4 Foreign Exchange (FX) Trunks. Not applicable.
10.5 Transport Channels. Not Applicable.
10.6 Data Point-to-Point Circuits.
| # |
| Circuit ID/Name |
| Rate (Kbps) |
| A_Location |
| Z_Location |
| Description |
| 38.RTNJ.306173..CM. |
| Voice Grade |
| Bldg 311, Longs Corner Rd, Aberdeen Proving Ground |
| Bldg 10301, Rd, Churchville, MD |
| ATC |
| 38.RTNJ.306174..CM |
| Voice Grade |
| Bldg 311, Longs Corner Rd, Aberdeen Proving |
Ground
| Bldg 10301, Rd, Churchville, MD |
| ATC |
| 38.RTNJ.321359..CM |
| Voice Grade |
| Bldg 311, Longs Corner Rd, Aberdeen Proving |
Ground
| Bldg 10301, Rd, Churchville, MD |
| ATC |
38.LADA.100290..MD
2-wire
1122 Edgewood Road, Edgewood, MD 21040
| 1601 Hanson Road, Edgewood, MD 21040 |
| DPW, Van Bibber Water Treatment Plant and Hanson Reservoir. |
TBD
10M Ethernet Bldg 311, Longs Corner Rd, Aberdeen Proving Ground 775 Priestford Rd, Churchville, Md 21028
ATC
10.7 OPX Lines
| # |
| Circuit ID/Name |
| Type |
| Rate (Kbps) |
| A_Location |
| Z_Location |
| Circuit Description |
38.OSNJ.306479..CM
Extended line connection off premise
Voice Grade
| Bldg 311, Longs Corner Rd, Aberdeen Proving Ground |
| BLDG 10306 |
Churchville Road, Aberdeen, Md Connection of circuit to customer provided equipment
38.OSNJ.306480..CM
Extended line connection off premise
Voice Grade
| Bldg 311, Longs Corner Rd, Aberdeen Proving Ground |
| BLDG 10306 |
Churchville Road, Aberdeen, Md Connection of circuit to customer provided
38.OSNJ.306481..CM
Extended line connection off premise
Voice Grade
| Bldg 311, Longs Corner Rd, Aberdeen Proving Ground |
| BLDG 10306 |
Churchville Road, Aberdeen, Md Connection of circuit to customer provided
56OSNP143
| Circuit connection OPX Line |
| Voice Grade |
| 775 Priestford Road, Churchville, MD |
| Churchville Test Area, Bldg 10301, Churchville, MD |
| Line extended |
38.OSNJ.259962..CM
Extended line connection- off premises OPX 278-
Voice Grade
| 775 Priestford Road, Churchville, MD |
| Bldg 10301, Rd, Churchville, MD |
| Extended line connection-off premises |
38.OSNJ.259964..CM
Ext. line connection- off premises OPX 278-
Voice Grade
| 775 Priestford Road, Churchville, MD |
| Bldg 10301, Rd, Churchville, MD |
| Extended line connection-off premises |
55MS58
Circuit Speed/ckt type Unknown
Voice Grade Bldg 311, Longs Corner Rd, Aberdeen Proving Ground Bldg 300, Aberdeen Proving Ground
96FDDJ2047
Circuit connection, Half duplex Analog Data 9600 Baud
Voice Grade
| Bldg E5103, Longs Corner Rd, Aberdeen Proving Ground |
| Bldg E5126, Aberdeen Proving Ground (Edgewood Area) |
| Line extended; 2-wire 3122 channel |
38.OSNA.336479 CM
PBX station line- extended- signaling Speed/ckt type Unknown
Bldg E5103, Bond Road, Aberdeen Proving Ground, MD 21010
1224 Everette Road, Aberdeen Proving Ground (Edgewood Area)
Line-extended Intraexchange Local Channel Off Prem Ext To PBX
38.OSNJ.287938 CM
PBX station line- extended- signaling Speed/ckt type Unknown
Bldg 1472E Aberdeen Proving Ground (Edgewood Area)
38.OSNJ.289175 CM
PBX station line- extended- signaling Speed/ckt type Unknown
Rt 755 & Rt 40 Van Bibber Pump Station, Edgewood
10.8 Diversity.
Currently both Government switches are connected via separate COs with Government fiber connecting the switches. Two separate physical paths off Aberdeen Proving Ground to two separate commercial offices must be maintained for this proposal. The Government requires a diversity solution connecting the Government switches in Building 311, Longs Corner Road (Aberdeen) and Building E5103, Bond Road (Edgewood). The solution must include connectivity to two separate central offices. The Government has identified its current solution as an OC-12 SONET.
Appendix 20
Example Diagram of Network Connectivity.
APPENDIX 30
DEFINITIONS
This Appendix provides the basic definitions and service functions of local communications services under the scope of this contract. The Government requires the Contractor to abide by the performance level and functionality of the local exchange, access, and transport services defined by standard network levels for lines, trunks, and…