This statement of work specifies requirements for replacing commercial washing machines at the Federal Medical Center in Lexington, Kentucky. The Bureau of Prisons intends to award a single contract to purchase and install two UniMac-UniWash 160 lb washer extractors or approved equal products. The washers must have a capacity of 160 pounds, operate on 208-240/60/3-amp electrical, and meet other specified technical requirements. The contractor will provide startup and training after installation is completed. Utilities will be provided by the Bureau of Prisons, while the contractor is responsible for all other equipment, supplies, and materials to complete the project. Employees must complete a NCIC form and adhere to security and safety requirements while on site.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF1449 Washing Machines.pdf | ||
| Solicitation Cover Letter - washing machine.rtf | RTF text file |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK/SPECIFICATIONS
FMC LEXINGTON - PROJECT 23Z1AL6
Replace Washers
I. SPECIFICATIONS:
A. INTRODUCTION
The Federal Bureau of Prisons (FBOP), Federal Medical Center located at 3301 Leestown Road in Lexington, Kentucky intends to make a single award to a responsible entity that will provide all necessary equipment, materials, and incidentals to purchase two (2) new UniMac-UniWash 160 lb. washer extractor, or an equal product, under no circumstance have no means to have the capability of connecting to the internet. Pricing will include shipping to the above address and installation.
All equipment specified in this statement must be brand name or an equal product. Should your firm choose to submit an equal product, you must submit all technical specification of the equal product to be analyzed and a technical determination issued with acceptance/non-acceptance. The government retains the right to determine technical acceptance for all submitted equal products.
B. SCOPE OF WORK
1. Provide Materials to Replace (2ea) Existing UniMac-UniWash 160 lb:
• The contractor shall be responsible for supplying and installing 2-UniMac-UniWash 160 lb capacity washer/ extractor model #UWT160V40V or approved equal product pending a technical review. Review will verify equipment does not exceed the following specifications:
o Capacity- 160 pounds o 208-240/60/3-amp electrical requirement o Cylinder Diameter-42 inches o Cylinder Depth- 30 inches o Cylinder Volume- 24.1 cubic feet o Height-72.6 inches o Width-47.33 inches o Depth-62.5 inches o Door Opening Size-24.8 inches.
o Door Bottom to floor-30.5 o Motor Size- 12 HP o Drain o Steam connection o Water Inlet Connection
• The vendor will provide Startup/Training after install is completed by institution.
• Awardee will be responsible for all materials, ancillary equipment and tools required for a complete installation of two (2) UniMac 160 lb washers, or equivalent.
D. UTILITIES
The FBOP will provide water, use of restrooms and minimal electricity service (120V) for small hand power tools including battery chargers. The manufacturer’s representative will provide all other equipment, supplies and materials needed to complete this project.
II. CONTRACTOR SECURITY/WORKING REGULATIONS
A. Work Hours:
N/A
B. Delivery of Materials:
All construction materials/equipment required for work on this project is required to be processed by the Contractor and coordinated with the institution COR for temporary storage.
Any construction related deliveries, which are directly shipped to the contractor, can be received between the hours of 7:00 a.m. to 12:00 p.m., Monday through Friday, excluding Federal Holidays. The contractor or his representative must be present to verify and accept the delivery.
Under no circumstances will FMC Lexington or its staff be responsible for the acceptance of any Contractor or company deliveries. The contractor shall be responsible for providing their own means of loading and unloading contractor material or equipment.
The contractor shall not use the institution entry/driveway for the loading, unloading, or storage of any materials and equipment. The contractor will not impede/block the driveway at any time.
C. Storage of Materials and Equipment:
N/A
D. Security Clearance/Contractor Badges:
Employees will be required to complete a NCIC form before being granted entry into FMC Lexington.
E. Safety and Personal Protective Equipment:
The manufacturer’s representative shall have and wear the required personal protective equipment (PPE) prescribed by industry standards at all times while on the job site.
F. Additional Considerations:
1. Contractors will NOT be allowed to bring cell phones, cameras or two-way pagers into FMC Lexington. The Facilities Department maintains a digital camera that will be utilized by BOP staff to document the project work. The Contractor may request copies of these documentation photos for record keeping.
2. Contractor shall not wear shorts, green, khaki-color clothing or any clothing with offensive, suggestive, illicit drug or anti-government slogans.