231101 - DRAWINGS.pdf
PDF 911 KB Posted
- Solicitation number
- 2137043
- Issued by
- St. Lawrence County, New York
About this file
This is a set of construction drawings and bid documents for the State University of New York at Canton related to the upgrade of the electrical panel and uninterruptible power supply system at Southworth Library. The project, numbered 231101 and located at 34 Cornell Drive, Canton, New York, involves the removal and renovation of electrical power and lighting systems. The bid documents include title sheets, general notes with symbols and abbreviations, removal power and lighting plans, renovation power and lighting plans, and partial one-line diagrams prepared by C&S Companies (Project Number 838040001). Sealed bids for this project are due by 2:00 p.m. on August 3, 2026, at French Hall Room 206 on campus, with all work to be completed by February 26, 2027. A mandatory pre-bid walkthrough is scheduled for July 22, 2026, at 10:00 a.m. at the Cooper Service Complex. Complete contract documents are available for download at http://www.canton.edu/procurement/bid_materials.html and may also be examined at the Cooper Service Complex.
Bids must be submitted in duplicate with security required in an amount not less than five percent of the total bid. The State University of New York has established contracting goals for minority and women business enterprises, with a Service-Disabled Veteran-Owned Business goal of 6.00 percent, a Minority Business Enterprise goal of 11.00 percent, and a Women Business Enterprise goal of 19.00 percent. The Disadvantaged Business Enterprise contracting goal is 0.00 percent. No business enterprises have been awarded an identical or substantially similar procurement contract within the past five years. The State University of New York reserves the right to reject any or all bids received.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 231101 - PROJECT MANUAL.pdf | ||
| 231101 - Addendum 1_07.29.2026.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PLAN
NORTH
Copyright ©
BID DOCUMENTS
FOR THE CONSTRUCTION OF
NO ALTERATION PERMITTED HEREON EXCEPT AS PROVIDED UNDER
SECTION 7209 SUBDIVISION 2 OF THE NEW YORK EDUCATION LAW
LOCATION MAP
TO THE BEST OF OUR KNOWLEDGE, INFORMATION AND BELIEF, THE
PLANS AND SPECIFICATIONS FOR THIS PROJECT ARE IN COMPLIANCE
WITH THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEW
YORK STATE AND THE BUILDING CODE OF NEW YORK STATE
UPGRADE ELECTRICAL PANEL &
UNINTERRUPTIBLE POWER SUPPLY-
SOUTHWORTH LIBRARY
STATE UNIVERSITY OF NEW YORK AT CANTON
34 CORNELL DR, CANTON, NY 13617
JUNE 18, 2026
G−001
C&S PROJECT NUMBER: 838040001
SUCF PROJECT NUMBER: 231101
SHEET LIST
SHEET NUMBER SHEET NAME
G-001 TITLE SHEET
E-001 GENERAL NOTES, SYMBOLS, ABBREVIATIONS & LUMINAIRE SCHEDULE
ED-101 REMOVAL POWER PLAN
ED-102 REMOVAL LIGHTING PLAN
E-101 RENOVATION POWER PLAN
E-102 RENOVATION LIGHTING PLAN
E-501 PARTIAL ONE-LINE DIAGRAMS
u N y
CANTON
E9
C®S
COMPANIES®
~'\ G[_<>i 01' 0o"" 'q: 7
IB" ''!\<,~,'/ii, - * I:. ,., = cc
4 \-ss 10\\~ cu cu
CONNECTION POINT OR CABLE SPLICE
TRANSFORMER
CIRCUIT BREAKER
GROUND
ONE-LINE SYMBOLS
PANELBOARD
1. COORDINATE REMOVAL WITH OTHER CONTRACTORS.
2. CONDUCT REMOVAL TO MINIMIZE INTERFERENCE WITH OCCUPIED BUILDING AREAS. SERVICE TO OTHER
PARTS OF BUILDING SHALL REMAIN ACTIVE.
3. DISCONNECT, CAP, AND IDENTIFY DESIGNATED UTILITIES WITHIN REMOVAL AREAS.
4. REMOVE IN AN ORDERLY AND CAREFUL MANNER, PROTECT EXISTING SUPPORTING STRUCTURAL
MEMBERS AND PARTITIONS TO REMAIN.
5. EXCEPT WHERE NOTED OTHERWISE, REMOVE REMOVAL MATERIALS FROM SITE. DO NOT DISPOSE OF
ANY MATERIAL ON SITE.
6. REMOVE REMOVAL MATERIAL FROM SITE AS WORK PROGRESSES. UPON COMPLETION OF WORK LEAVE
AREAS IN CLEAN CONDITION.
7. REMOVAL SHALL INCLUDE REMOVAL OF ALL STRAPS, HANGERS, CLAMPS, CHANNEL, AND OTHER DEVICES
USED FOR SUPPORTING EQUIPMENT.
8. PRIOR TO ENGAGING IN REMOVAL WORK, CONTRACTOR SHALL NOTIFY ENGINEER OF ANY
DISCREPANCIES BETWEEEN EXISTING FIELD CONDITIONS AND PROJECT DRAWINGS.
1. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE, LOCAL, AND NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CHARACTERISTICS SHALL BE VERIFIED WITH EQUIPMENT MANUFACTURER.
3. ITEMS OF SPECIFIC MANUFACTURERS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH
MANUFACTURER'S PRINTED INSTRUCTIONS AND/OR MANUFACTURER'S REPRESENTATIVE'S DIRECTIONS.
4. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS AND DIMENSIONS SHOWN ON DRAWINGS.
5. ALL CONDUIT AND WIRING SCHEDULES SHALL BE VERIFIED BEFORE INSTALLATION.
6. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL EQUIPMENT WITH OTHER
CONTRACTORS.
7. ALL AREAS DISTURBED BY WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN
ORIGINAL AS DETERMINED BY THE ENGINEER.
8. THE CONTRACTOR SHALL PROVIDE RACEWAYS, WIRING, AND CONNECTIONS FOR ALL CONTROL CIRCUITS
AND INTERLOCK.
9. ALL ELECTRICAL CONDUIT AND CONDUCTORS DISCONNECTED AND NOT TO BE REUSED SHALL BE
REMOVED.
10. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS BEFORE STARTING WORK. IF ONLY A PORTION OF AN EXISTING CIRCUIT IS BEING REMOVED FOR DEMOLITION, CONTINUITY SHALL BE
MAINTAINED TO THE REST OF THE REMAINING CIRCUIT.
11. ALL BRANCH CIRCUIT CONDUCTORS SHALL BE #12AWG UNLESS OTHERWISE SHOWN.
12. ALL BRANCH CIRCUITS SHALL CONSIST OF 2 CONDUCTORS PLUS GROUND, UNLESS OTHERWISE SHOWN.
A AMPERE
A/C AIR CONDITIONING
AC ALTERNATE CURRENT
ACCU AIR COOLED CONDENSING UNIT
AF AMPERE FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
A/H AIR HANDLER
AIC AMPERE INTERRUPTING CAPACITY
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AU AT UNIT
AUX AUXILIARY
AWG AMERICAN WIRE GAUGE
BC BARE COPPER
BFG BELOW FINISHED GRADE
BRK BREAKER
BOH BACK OF HOUSE
C CONDUIT
CA CABLE
CAB CABINET
CAT5E CATEGORY-5E
CC CABLED CONDUCTORS
CH CHILLER
CKT CIRCUIT
CLL CONTRACT LIMIT LINE
CMH COMMUNICATION MANHOLE
CO CONDUIT ONLY
COMM COMMUNICATION
CPB COMMUNICATION PULLBOX
CT CURRENT TRANSFORMER
CTR ABOVE COUNTER
CUC COMMON USER CABLE
CUTC COMMON USER TERMINAL CABINET
D DEEP
DC DIRECT CURRENT
DISC DISCONNECT
DN DOWN
DP DISTRIBUTION PANEL
DPST DOUBLE POLE SINGLE THROW
DPDT DOUBLE POLE DOUBLE THROW
EER ELECTRICAL EQUIPMENT ROOM
ELECT ELECTRICAL
ELEV ELEVATION
EMT ELECTRICAL METALLIC TUBING
EQUIP EQUIPMENT
EXIST EXISTING
F FUSE
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FAT FIRE ALARM TERMINATION
FBO FURNISHED BY OWNER
FD/SD FIRE DAMPER / SMOKE DETECTOR
FDR FEEDER
FLA FULL LOAD AMPERES
GFI GROUND FAULT INTERRUPT
GND GROUND
H HIGH
HP HORSEPOWER
HZ HERTZ
I/C INTERCOM
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
IT INFORMATION TECHNOLOGY
JB JUNCTION BOX
KA KILOAMP
KV KILOVOLT
KVA KILOVOLT AMPERES
KW KILOWATT
KWH KILOWATT HOUR
KWHD KILOWATT HOUR DEMAND METER
L LENGTH, LONG
LGT LIGHTING
MA MILLIAMPERES
MBB MONITOR BREAKOUT BOX
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MCM 1000 CIRCULAR MILLS
MECH MECHANICAL
MIC MICROPHONE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MM MULTI MODE
MTD MOUNTED
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASS.
NF NON-FUSED
NFPA NATIONAL FIRE PROTECTION ASS.
NO NORMALLY OPEN
NTS NOT TO SCALE
OLS OVERLOADS
OC ON CENTER
P POLE
PB PULLBOX
PNL PANEL
PR PAIR
PVC POLYVINYL CHLORIDE
PWR POWER
POC POINT OF CONNECTION
POS POINT OF SALES
PT POTENTIAL TRANSFORMER
REF REFERENCE
REM REMARKS
RGS RIGID GALVANIZED STEEL
RM ROOM
RMS ROOT-MEAN-SQUARE
RCPT RECEPTACLE
SBB SOUND BREAKOUT BOX
SDB SOUND DISTRIBUTION BOX
SLC SIGNALING LINE CIRCUIT
SM SINGLE MODE
SPECS SPECIFICATIONS
SPKR SPEAKER
SPST SINGLE POLE SINGLE THROW
SPDT SINGLE POLE DOUBLE THROW
SR SOUND RACK
SST STAINLESS STEEL
ST SHUNT TRIP
SW SWITCH
SWBD SWITCHBOARD
TEL TELEPHONE
TP TWISTED PAIR CABLE
TTB TELEPHONE TERMINAL BOARD
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE PWOER SUPPLY
V VOLT
VFD VARIABLE FREQUENCY DRIVE
W WATT, WIRE, WIDE
WP WEATHERPROOF
XFMR TRANSFORMER
S
EXISTING WORK LINETYPE
DEMOLITION WORK LINETYPE
NEW WORK LINETYPE
SWITCH
PLAN SYMBOLS
A
2'X4' LUMINAIRE, LETTER DENOTES TYPE, SEE LUMINAIRE SCHEDULE
A RECESSED DOWN LIGHT, LETTER DENOTES TYPE, SEE LUMINAIRE SCHEDULE
PANEL BOARD
SCOPE OF WORK BOUNDARY
1. UNIVERSITY TO REMOVE FURNITURE AND ASSOCIATED MATERIALS IN LOCATION INDICATED ON FLOOR PLAN FOR NEW UPS UNIT. THIS SPACE MUST BE CLEAR BEFORE ANY CONSTRUCTION CAN BEGIN. CONTRATOR TO
COORDINATE THIS EFFORT WITH UNIVERSITY.
2. PROVIDE UPGRADES TO "DPHE-1" TO ACCOMMODATE NEW UPS.
3. INSTALL NEW UPS UNIT IN CLEAR SPACE INDICATED ON FLOOR PLAN.
4. PROVIDE CONDUIT AND WIRING TO UPS UNIT AS SHOWN ON DRAWINGS.
5. PROVIDE CONDUIT AND WIRING TO IT DISTRIBUTION BUS BARS AS SHOWN ON DRAWINGS. FINAL TERMINATION
WILL NOT BE MADE UNTIL EXISTING TERMINATIONS FROM EXISTING UNIT ARE REMOVED.
6. DE-ENERGIZE EXISTING UPS.
7. REMOVE EXISTING UPS TERMINATIONS TO BUS BAR AND TERMINATE NEW UPS BRANCH CIRCUITS.
8. ENERGIZE NEW UPS.
9. COMPLETE SWITCH OVER, TESTING AND COMMISSIONING OF NEW UPS UNIT.
10. REMOVE OLD UNIT.
11. COMPLETE CONDUIT AND WIRING REMOVALS BACK TO SOURCE FOR UPS UNIT THAT HAS NOT BEEN REMOVED.
*CONTRACTOR SHALL INCLUDE OFF-HOURS TIME IN ORDER TO COMPLETE WORK ASSOCIATED WITH UPS. WORK THAT
WILL AFFECT CAMPUS OPERATIONS MUST BE PERFORMED DURING OFF-HOURS.
NO ALTERATION PERMITTED HEREON
EXCEPT AS PROVIDED UNDER SECTION
7209 SUBDIVISION 2 OF THE NEW YORK
EDUCATION LAW
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJECT NO:
DATE
DATE:
MARK
REVISIONS
DESCRIPTION
A
1 2 3
1 2 3
C
A
D
B
C
D
B
499 Col. Eileen Collins Blvd Syracuse, New York 13212
Phone: 315-455-2000 Fax: 315-455-9667 www.cscos.com
C&S Engineers, Inc.
Copyright ©
JUNE 18, 2026
C. M. FRANCIS
R. M. GLEASON, PE
R. M. GLEASON, PE
838040001
GENERAL NOTES,
SYMBOLS,
ABBREVIATIONS &
LUMINAIRE SCHEDULE
E-001
U P
G R
A D
E E
L E
C T
R
IC
A L
P A
N E
L
U N
IN
T
E R
R U
P T
IB
L E
P O
W E
R S
U P
P L
Y
S O
U T
H W
O R
T H
L
IB
R A
R Y
S T
A T
E U
N
IV
E R
S
IT
Y O
F N
E W
Y O
R K
A T
C A
N T
O N
C
O R
N E
L L
D R
C
A N
T O
N
N Y
SCALE: NOT TO SCALEA4 ONE-LINE SYMBOLS
SCALE: NOT TO SCALEA2 GENERAL REMOVAL NOTES
SCALE: NOT TO SCALEB2 GENERAL NOTES
SCALE: NOT TO SCALEA3 ABBREVIATIONS
SCALE: NOT TO SCALEB4 PLAN SYMBOLS
SCALE: NOT TO SCALEC2 CONSTRUCTION SEQUENCING PLAN
LUMINAIRE SCHEDULE
FIXTURE
LABEL
MANUFACTURER
MODEL NUMBER
LAMP
TYPE
VOLTS DRIVER
LUMENS
PER UNIT
COLOR TEMP /
CRI
MOUNTING REMARKS
LA1 METALUX 24EN-LD2-67UNV-L835-CD1 LED UNIVERSAL LED 6500 3500 CEILING -
LA2 PORTFOLIO 8LBM2MW LED UNIVERSAL LED 1000 3500 CEILING 1
SCALE: NOT TO SCALED3 LUMINIARE SCHEDULE
REMARKS
1. PROVIDE TRIM RING TO COVER EXISTING APERTURE.
I I r·7 I I
I I I I L _ _J
I -
0 0
\..AAA.)
rYVY"\
J_
T
[I] s s or NE,v '?-'- E Gi_ f'.
eo'- <>i " f l'IM!I~ =:
SSIO
cu cu y
CANTON
DISCONNECT INCOMING SUPPLY CONDUIT AND WIRING TO 50KW UPS. UPS IS SERVED VIA 480V DISTRIBUTION SWITCHBOARD "DPHE-1" LOCATED IN STORAGE ROOM B32. REMOVE CONDUIT AND WIRING FROM UPS TO BE REMOVED BACK TO PANELBOARD DPHE-1. REFER TO CONSTRUCTION SEQUENCING PLAN, E-001, AND ONE-LINE DIAGRAM, E-501, FOR FURTHER DETAILS. CIRCUIT BREAKER SHALL BE MARKED
AS SPARE ONCE REMOVAL WORK IS COMPLETE. UPDATE PANEL SCHEDULE ACCORDINGLY.
DISCONNECT (4) FOUR OUTGOING CIRCUITS FROM 50KVA UPS. EACH CIRCUIT CONSISTS OF 4-#2AWG + 1-#8G IN 1-1/4" CONDUIT. CIRCUITS ARE RESPONSIBLE FOR SERVING 100A BUSWAY LOCATED IN SERVER
ROOM 002. REMOVE CONDUIT AND WIRING FROM BUSWAY RUNNING THROUGH SERVER ROOM 002.
REMOVE 50KW UPS IN ITS ENTIRETY. DISASSEMBLE ACCORDINGLY IN ORDER TO ACCOMMODATE DOOR
AND ELEVATOR CONSTRAINTS.
SCOPE OF WORK BOUNDARY FOR ED-101.
SHOWN FOR REFERENCE ONLY.
BUSWAY ENERGIZATION TO NEW UPS TO OCCUR DURING OFF HOURS. COORDINATE WITH UNIVERSITY AT LEAST TWO WEEKS PRIOR TO PERFORMING WORK. ALL INFRASTRUCTURE SHALL BE IN PLACE PRIOR TO
DE-ENERGIZATION OF EXISTING UPS UNIT.
APPROXIMATE LOCATION OF EXISTING BUSWAY. CONTRACTOR TO CONFIRM ACTUAL BUSWAY SYSTEM
TERMINATION LOCATIONS.
EXISTING UPS
50KW
ELECTRICAL CLOSET
B35
ELECTRICAL CLOSET
B15
STORAGE
B32
STORAGE
B33
SERVER
MM STORAGE
003A
MM EDITING
HD TECH LABS MGR
DPLE-1 DPHE-1
NO ALTERATION PERMITTED HEREON
EXCEPT AS PROVIDED UNDER SECTION
7209 SUBDIVISION 2 OF THE NEW YORK
EDUCATION LAW
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJECT NO:
DATE
DATE:
MARK
REVISIONS
DESCRIPTION
A
1 2 3
1 2 3
C
A
D
B
C
D
B
499 Col. Eileen Collins Blvd Syracuse, New York 13212
Phone: 315-455-2000 Fax: 315-455-9667 www.cscos.com
C&S Engineers, Inc.
Copyright ©
JUNE 18, 2026
C. M. FRANCIS
R. M. GLEASON, PE
R. M. GLEASON, PE
838040001
REMOVAL POWER PLAN
ED-101
U P
G R
A D
E E
L E
C T
R
IC
A L
P A
N E
L
U N
IN
T
E R
R U
P T
IB
L E
P O
W E
R S
U P
P L
Y
S O
U T
H W
O R
T H
L
IB
R A
R Y
S T
A T
E U
N
IV
E R
S
IT
Y O
F N
E W
Y O
R K
A T
C A
N T
O N
C
O R
N E
L L
D R
C
A N
T O
N
N Y
0 16'8'4'
PLAN
NORTH
SCALE: NOT TO SCALEA4 KEYED NOTES-
SCALE: 1/8" = 1'-0"A1 REMOVAL POWER PLAN
[8]
. , .. - s
I I' 71
CT]
I I
[8] CT] [8] [8]
• I I ; I ';=_-----0 ______ __J I
--- I l=========l I I i I I I ~I ~I
I I "' I l';=(---________ __JI
I Q
I 8n-T-,7
I
I I
1==========1 I ______ __J
I I I I I I I ______ _____:
l=========l
Fl ======a!__---'~ i gu_1-_L_J I I
I "-'------1~
¢=~=:::;:::::::I...LJ --- - - - -------[8 [8] [8]
a
0 0 0 0
1--------1--------C----- I-----
0 0 0 0 a
I
I
[8] [8]
-----------1 f ===i===j!
I I l===l===li I
Lr------17 H I
/ '~-HI~ LJ z ~ : ~ I
IT 0
LL
I rbb
,;::======;-;:====='-'====I u u C8J lV\,_________, '::::=::::1=;::::r::
I
I I
I
~=====iii"¾ I
I
I
[8] [8]
I -I
I ~
I I I I I I
L_
I
EB
s or NE,v "'?-'- E Gi_ f'.
eo'- <>i
,~11!,,=-* er cu cu
ESSI
- t-----------1 s y
SERVER
MM STORAGE
003A
MM EDITING
HD TECH LABS MGR
1 DISCONNECT AND REMOVE EXISTING LIGHTING FIXTURE. ASSOCIATED CONDUIT AND WIRING TO REMAIN
FOR INSTALLATION OF NEW LIGHTING FIXTURES.
2 SCOPE OF WORK BOUNDARY FOR ED-102.
NO ALTERATION PERMITTED HEREON
EXCEPT AS PROVIDED UNDER SECTION
7209 SUBDIVISION 2 OF THE NEW YORK
EDUCATION LAW
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJECT NO:
DATE
DATE:
MARK
REVISIONS
DESCRIPTION
A
1 2 3
1 2 3
C
A
D
B
C
D
B
499 Col. Eileen Collins Blvd Syracuse, New York 13212
Phone: 315-455-2000 Fax: 315-455-9667 www.cscos.com
C&S Engineers, Inc.
Copyright ©
JUNE 18, 2026
C. M. FRANCIS
R. M. GLEASON, PE
R. M. GLEASON, PE
838040001
REMOVAL LIGHTING
PLAN
ED-102
U P
G R
A D
E E
L E
C T
R
IC
A L
P A
N E
L
U N
IN
T
E R
R U
P T
IB
L E
P O
W E
R S
U P
P L
Y
S O
U T
H W
O R
T H
L
IB
R A
R Y
S T
A T
E U
N
IV
E R
S
IT
Y O
F N
E W
Y O
R K
A T
C A
N T
O N
C
O R
N E
L L
D R
C
A N
T O
N
N Y
0 16'8'4'
PLAN
NORTH
SCALE: 1/8" = 1'-0"A1 REMOVAL LIGHTING PLAN
SCALE: NOT TO SCALEA4 KEYED NOTES-
11 1
[8]
CT]
I
[8]
I i I or:::-7
L'-,,J I
I or:::-7 I L::::_-,,J
I
I i I I
~I =1' I or:::-7 I L '-,,J
I
I I i o_~ __ o~_ I o~ o~ o~ I
[8 [8] [8]
F p n n 0 0 I-- - - - - - -I-- - - - - - -1-- - - - - -- - - - - -
I-- - - - - - -I-- - - - - - -1-- - - - - -- - - - - -
0 0 0 0
II II
CT]
[8] [8]
I
[8]
, H >--------------.-..-----1
,~ ___ ,HI H
uu / >k'========'=:":::;;;;;;, ~1 (___ I ___,- I rT µ_
I Lb
C8J lV\1r::::==::::'...'::::=:r=:c::
[8] l
H
~_______, H e-c--l ____ ----'--jl ,---,e-c------------"j,---,e-c--1 ------"--jl H - - - - - - - - H t=~,,.----
~""::::'.::::'.:::====:'.J> "" "" LLL.Ll_-------G==~====::::J> - J
H H
;===~V'\=~'
I - I b
I I I I
I - L_
I - [8] [8]
I I
I I
I
EB
s s or NE,v '?-"\ E Gi_ f'.
eo" <>i " f l'IM!I~ =:
SSIO
cu cu
PROVIDE 4-#2AWG + 1-#8G IN 1-1/2" C TO 30KW UPS. UPS IS SERVED VIA 480V DISTRIBUTION SWITCHBOARD "DPHE-1" LOCATED IN STORAGE ROOM B32. PROVIDE 3P, 100A CIRCUIT BREAKER IN SWITCHBOARD TO
MATCH EXISTING CIRCUIT BREAKER CHARACTERISTICS.
PROVIDE (4) FOUR OUTGOING CIRCUITS FROM 30KW UPS. EACH CIRCUIT CONSISTS OF 4-#2AWG + 1-#8G IN 1-1/4" CONDUIT. CIRCUITS ARE RESPONSIBLE FOR SERVING 100A BUSWAY LOCATED IN SERVER ROOM 002.
PROVIDE 30KW UPS, 480V IN, 208/120V OUT (3 WIRE IN, 4 WIRE OUT). UPS SHALL BE EQUIPPED FOR 50KW FRAME CAPACITY. PRIOR TO INSTALLATION, CONTRACTOR SHALL CONFIRM INSTALLATION LOCATION WITH UNIVERSITY REPRESENTATIVE. INSTALLATION LOCATION SHALL CONSIDER MAINTENANCE ACCESSIBILITY, CLEARANCES, ETC.
SCOPE OF WORK BOUNDARY FOR E-101.
SHOWN FOR REFERENCE ONLY.
BUSWAY ENERGIZATION TO NEW UPS TO OCCUR DURING OFF HOURS. COORDINATE WITH UNIVERSITY AT LEAST TWO WEEKS PRIOR TO PERFORMING WORK. ALL INFRASTRUCTURE SHALL BE IN PLACE PRIOR TO
DE-ENERGIZATION OF EXISTING UPS UNIT.
APPROXIMATE LOCATION OF EXISTING BUSWAY. CONTRACTOR TO CONFIRM ACTUAL BUSWAY SYSTEM
TERMINATION LOCATIONS.
REPLACEMENT UPS
30KW
SERVER
MM STORAGE
003A
MM EDITING
HD TECH LABS MGR
ELECTRICAL CLOSET
B35
ELECTRICAL CLOSET
B15
STORAGE
B32
STORAGE
B33
DPLE-1 DPHE-1
NO ALTERATION PERMITTED HEREON
EXCEPT AS PROVIDED UNDER SECTION
7209 SUBDIVISION 2 OF THE NEW YORK
EDUCATION LAW
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJECT NO:
DATE
DATE:
MARK
REVISIONS
DESCRIPTION
A
1 2 3
1 2 3
C
A
D
B
C
D
B
499 Col. Eileen Collins Blvd Syracuse, New York 13212
Phone: 315-455-2000 Fax: 315-455-9667 www.cscos.com
C&S Engineers, Inc.
Copyright ©
JUNE 18, 2026
C. M. FRANCIS
R. M. GLEASON, PE
R. M. GLEASON, PE
838040001
RENOVATION POWER
PLAN
E-101
U P
G R
A D
E E
L E
C T
R
IC
A L
P A
N E
L
U N
IN
T
E R
R U
P T
IB
L E
P O
W E
R S
U P
P L
Y
S O
U T
H W
O R
T H
L
IB
R A
R Y
S T
A T
E U
N
IV
E R
S
IT
Y O
F N
E W
Y O
R K
A T
C A
N T
O N
C
O R
N E
L L
D R
C
A N
T O
N
N Y
0 16'8'4'
PLAN
NORTH
SCALE: NOT TO SCALEA4 KEYED NOTES-
SCALE: 1/8" = 1'-0"A1 RENOVATION POWER PLAN
I
[8] [8] CT]
~ ------------- --- I
I I I I I ~o------~ I j I I i I I
I 1o I I I I
! §~I ! I I /\ I - --- - - - -------I. I
" ' [8 [8] [8] [8] [8]
F p C i -----------1
0 0 0 0 1--- ---- -1-- - -- - ------ ----- ---- [===¾===] 1-- - - - - - -1-- - - - - - -r- - - - - -- - - - - -
-1--------1
6 0 0 0 0
[===¾===] b
I 1.--- 71
I I
CT]
I I
I
I
[8] [8] i===I-~ lb! /
¢==~======l-lJ: 'H I
/l_r--------1'~~,HJ; LJ (__
~ i ~- T _l_
I
,;:::::::':::::==-;::::::=:=-====I uu
~ V\~----==~· ~ 0
HH
[8]
I
I
[8]
I
EB
s or NE,v "'?-'- E GJ. f'.
eo'- <>i " f ~fflJ/, =:
SSIO
cu cu
LA1 LA1 LA1 LA1
LA1 LA1 LA1 LA1
LA1LA1LA1LA1
LA2 LA2 LA2 LA2 LA2 LA2
SERVER
1 UTILIZE EXISTING CONDUIT AND WIRING TO ACCOMMODATE FIXTURE INSTALLATION. EXTEND CONDUIT
AND WIRING AS NEEDED. UTILIZE EXISTING SWITCHING CONFIGURATION.
2 MODIFICATIONS SHALL BE MADE TO EXISTING APERTURE TO ACCOMODATE FIXTURE INSTALLATION.
3 SCOPE OF WORK BOUNDARY FOR E-102.
NO ALTERATION PERMITTED HEREON
EXCEPT AS PROVIDED UNDER SECTION
7209 SUBDIVISION 2 OF THE NEW YORK
EDUCATION LAW
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJECT NO:
DATE
DATE:
MARK
REVISIONS
DESCRIPTION
A
1 2 3
1 2 3
C
A
D
B
C
D
B
499 Col. Eileen Collins Blvd Syracuse, New York 13212
Phone: 315-455-2000 Fax: 315-455-9667 www.cscos.com
C&S Engineers, Inc.
Copyright ©
JUNE 18, 2026
C. M. FRANCIS
R. M. GLEASON, PE
R. M. GLEASON, PE
838040001
RENOVATION LIGHTING
PLAN
E-102
U P
G R
A D
E E
L E
C T
R
IC
A L
P A
N E
L
U N
IN
T
E R
R U
P T
IB
L E
P O
W E
R S
U P
P L
Y
S O
U T
H W
O R
T H
L
IB
R A
R Y
S T
A T
E U
N
IV
E R
S
IT
Y O
F N
E W
Y O
R K
A T
C A
N T
O N
C
O R
N E
L L
D R
C
A N
T O
N
N Y
0 16'8'4'
PLAN
NORTH
SCALE: 1/8" = 1'-0"A1 RENOVATION LIGHTING PLAN
SCALE: NOT TO SCALEA4 KEYED NOTES-
I
[8] [8] rn
I I
I Oe::;J Oe::;J Oe::;J Oe::;J I
I ~I ~I I
! 0 [::;] 0 [::;] '--------'Oe::;J Oe::;J I A I ~I =,I "
I Oe::;J Oe::;J Oe::;J Oe::;J I
I I
- i 8® 8® - ~ 8® 8® 8® i
'-'-------'/'..._ --- - - - -------[8 [8] [8] [8] [8] a C
-----------1
0 0 0 0 ,__ ______ ,__ __ ---- ------f-------
,__ ---- - _,__ -- -- - - ------r------
0 0 0 0 a C rn r -
I I
I
I
[8]
1;1
1;1
1:1
~1:1 =====---___,/'..._
H H
[8]
I
[8]
[8]
_H
H
I ~
I I I I I I
~ L_
EB
I s or NE,v '?-'- E Gi_ f'.
eo'- <>i " f ~fflJ/, =:
SSIO
cu cu
150A/3P100A/3P
125A/3P
PANEL DPHE-1 PANEL DPLE-1
MAINTENANCE BYPASS CABINET
UPS CABINET
BATTERY CABINET
50W UPS,
480V, 3⌀, 3W INPUT,
208/120V, 3⌀, 4W OUTPUT
75KVA, K-13 RATED
TRANSFORMER
'T-1', 480V PRIMARY,
208Y/120V SECONDARY
STORAGE ROOM B32
TO DOUBLE PANEL
100A/3P 100A/3P
UPS-1A (SEC. 1) UPS-1B (SEC. 2)
100A/3P
100A/3P
A SIDE
OF RACK
A SIDE
OF RACK
B SIDE
OF RACK
B SIDE
OF RACK
100A
BUSWAY
100A
BUSWAY
100A
BUSWAY
100A
BUSWAY
FROM ATS-1
SERVER ROOM 002
225A 225A
4-#2AWG + 1-#8G
1-1/4"C
4-#2AWG + 1-#8G
1-1/4"C
4-#2AWG + 1-#8G
1-1/4"C
4-#2AWG + 1-#8G
1-1/4"C
4-#2AWG + 1-#8G
1-1/2"C
150A/3P 100A/3P
125A/3P
PANEL DPHE-1 PANEL DPLE-1
MAINTENANCE BYPASS CABINET
UPS CABINET
BATTERY CABINET
30KW UPS, FRAME CAPACITY FOR 50KW (FUTURE),
480V, 3⌀, 3W INPUT,
208/120V, 3⌀, 4W OUTPUT
75KVA, K-13 RATED
TRANSFORMER
'T-1', 480V PRIMARY,
208Y/120V SECONDARY
STORAGE ROOM B32
TO DOUBLE PANEL
100A/3P 100A/3P
UPS-1A (SEC. 1) UPS-1B (SEC. 2)
100A/3P
100A/3P
A SIDE
OF RACK
A SIDE
OF RACK
B SIDE
OF RACK
B SIDE
OF RACK
100A
BUSWAY
100A
BUSWAY
100A
BUSWAY
100A
BUSWAY
FROM ATS-1
SERVER ROOM 002
225A 225A
100A/3P
4-#2AWG + 1-#8G
1-1/4"C
4-#2AWG + 1-#8G
1-1/4"C
4-#2AWG + 1-#8G
1-1/4"C
4-#2AWG + 1-#8G
1-1/4"C
4-#2AWG + 1-#8G
1-1/2"C
1. REFER TO CONSTRUCTION SEQUENCING PLAN, E-001, FOR FURTHER DETAILS.
BUSWAY ENERGIZATION TO NEW UPS TO OCCUR DURING OFF HOURS. COORDINATE WITH
UNIVERSITY AT LEAST TWO WEEKS PRIOR TO PERFORMING WORK. ALL INFRASTRUCTURE SHALL
BE IN PLACE PRIOR TO DE-ENERGIZATION OF EXISTING UPS UNIT.
NO ALTERATION PERMITTED HEREON
EXCEPT AS PROVIDED UNDER SECTION
7209 SUBDIVISION 2 OF THE NEW YORK
EDUCATION LAW
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJECT NO:
DATE
DATE:
MARK
REVISIONS
DESCRIPTION
A
1 2 3
1 2 3
C
A
D
B
C
D
B
499 Col. Eileen Collins Blvd Syracuse, New York 13212
Phone: 315-455-2000 Fax: 315-455-9667 www.cscos.com
C&S Engineers, Inc.
Copyright ©
JUNE 18, 2026
C. M. FRANCIS
R. M. GLEASON, PE
R. M. GLEASON, PE
838040001
PARTIAL ONE-LINE
DIAGRAMS
E-501
U P
G R
A D
E E
L E
C T
R
IC
A L
P A
N E
L
U N
IN
T
E R
R U
P T
IB
L E
P O
W E
R S
U P
P L
Y
S O
U T
H W
O R
T H
L
IB
R A
R Y
S T
A T
E U
N
IV
E R
S
IT
Y O
F N
E W
Y O
R K
A T
C A
N T
O N
C
O R
N E
L L
D R
C
A N
T O
N
N Y
SCALE: NOT TO SCALEC1 PARTIAL REMOVAL ONE-LINE DIAGRAM
SCALE: NOT TO SCALEA1 PARTIAL RENOVATION ONE-LINE DIAGRAM
SCALE: NOT TO SCALEA4 GENERAL NOTES
SCALE: NOT TO SCALEB4 KEYED NOTES- X
1 1 11
1 1 11
I I
,--------------------------- I -------------------------------------------------7
---->--0 o-+----, ,........._____::J l p p p I
L ___________________________ I _________________________________________________ _J
,--------------------------- I -------------------------------------------------7
I
>--0 0-
------.. ·~ ,-0 - I l.
---- I >--0
I
,-L---. --------'--,' ~
I
0 ,, --
::i d
~ -- -- -- -- -f- - -- ---- -- 1)
I
I
I
I I
I
I
I
I d 0
L ___________________________ I _________________________________________________ _J
I I s s or NE,v '?-'- E Gi_ f'.
eo'- <>i " f l'IM!I~ =:
SSIO
cu cu
| Sheets |
| E-001 - GENERAL NOTES, SYMBOLS, ABBREVIATIONS & LUMINAIRE SCHEDULE |
| E-101 - RENOVATION POWER PLAN |
| E-102 - RENOVATION LIGHTING PLAN |
| E-501 - PARTIAL ONE-LINE DIAGRAMS |
| ED-101 - REMOVAL POWER PLAN |
| ED-102 - REMOVAL LIGHTING PLAN |
| G-001 - TITLE SHEET |
File details come from the government source that posted it. Updated .