STATEMENT OF WORK
United States Department of Commerce National Oceanic and Atmospheric Administration, National Ocean Service Center for Operational Oceanographic Products and Services (CO-OPS) Field Operations Division, Atlantic Operations Branch Aluminum Vehicle Shelving Units and Modification June 27th 2022
NC-NT2000-22-01244
1. BACKGROUND
The Center for Operational Oceanographic Products and Services (CO-OPS) collects analyzes and distributes historical and real-time observations and predictions of water levels, coastal currents and other meteorological and oceanographic data. This is part of an integrated National Ocean Service (NOS) program supporting safe maritime navigation, more productive water-borne commerce, and the needs of the National Weather Service, coastal zone management, engineering and surveying communities. The Center manages the National Water Level Observation Network (NWLON) around the coastal United States and the national network of Physical Oceanographic Real-Time Systems (PORTS®) in major U.S. harbors. It conducts its programs through university, industry, Federal and State partnerships as appropriate. CO-OPS resides within NOAA's National Ocean Service.
The Field Operations Division (FOD) installs and maintains a variety of oceanographic and meteorological equipment and provides support services in order to ensure the efficient collection and dissemination of CO-OPS water level and meteorological data. Collection of tidal water level data at most locations requires a variety of differing types on instrumentation such as pressure sensors, gas purges, encoders, microwaves and GPS. There is also other data collected such as air gap, current meters, towers with wind, air temp, relative humidity, barometer and other like ancillary sensors. The data are then provided in real time via several means including by hard phone lines, IP modem and through the GOES satellite system. CO-OPS transmit data from the majority of its NWLON and PORTS stations via the GOES satellite network.
2. OBJECTIVE
CO-OPS use large work vehicles such as Ford 4-Door F-450 Trucks for the installation and maintenance of its temporary and permanent water level stations. In order for these vehicles to be of proper use they must be outfitted accordingly with shelves, bins, drawers, custom interior shelves, emergency lighting, additional standard lighting, roof racks with strapping system, safety steps, safety handles, exterior cabinets for lubricants, cleaners and a designated space for SCUBA tank and equipment storage. It has been determined from previous experience that Reading truck work cabs will stand up to the heavy use and mileage that CO-OPS vehicles are exposed to on a regular basis. Reading Truck Products are heavy duty enough to last the length of the vehicle use. This purchase is for outfitting 2 new Ford F-450 diesel trucks with Reading work cabs and future orders that are custom modified in order to allow for enhanced maintenance of sites for permanent NWLON and PORTS stations as well as temporary installations in support of NOAA hydrography, photogrammetry, V-Datum, and special projects. The 2 recently purchased 4 door Ford F-450 Trucks, stripped chassis orders require work cabs and bumpers be installed and then be DOT certified in order to properly and legally operate.
3. REQUIREMENTS
Both Reading work cabs will be READING CLASSIC 2 ENCLOSED BODY, A&B compartment layout.
· READING MODEL SPM60-108ABDW – 11’ CLASSIC II DW Steel spacemaster body, Enclosed Body (requires custom installation for DEF). 2 Each includes:
· 108” L x 91 1/2” W – 72” inside head clearance
· “A” Compartment Layout – R/S
· “B” Compartment Layout – C/S
· 5” Understructure
· Tapered Spacemaster Top Includes:
· One full length Compartment both sides
· With lift-up doors for outside access
· R/S includes interior drop down doors
· C/S Includes shelf
· Full length shelf above compartments
· Full rear doors – with window in each door
· One (1) permanent window in front bulkhead
· 48.5 “ wide load space – flat diamond plate floor
· Patented hidden hinges on all doors
· SS rotary paddle latches on all doors
· Nitrogen strut door holders all vert doors
· LED rear lights – S/T/T & backup
· E coat immersion primer – PC white finish
· 6 year limited warranty
· Eliminate glass and cut-out in front bulkhead
· Incorporate (1) 10” deep plain permanent shelf with a 2” high lip across front of spacemaster assembly even with upper full length shelves
· Incorporate (1) 18” deep plain permanent shelf with a 2” high lip across front of spacemaster assembly even with top of side compartments
· Incorporate (1) drop down rear access door in rear end panel of spacemaster roadside and curbside
· Incorporate an offset in front vertical compartment curbside for DEF tank clearance
· Body to include masterlocking – spring loaded locking system – roadside/curbside
· Recessed Pooched bumper – powder coat white
· Incorporate shelf in horizontal compartment curbside to be permanent & include a permanent center shelf support
· Furnish and install DEF fill mounting bracket
· Chassis equipped with dual/midship tank configuration. Incorporate offset, curbside front vertical compartment to accommodate DEF tank
· CTECH drawer unit installed in front compartment roadside consisting of (3) 3” high drawers, (2) 5” high and (1) 7” high drawer
· Products model SL-100 chrome plated security lock for rear panel doors
· Four corner strobes – (2) ECCO model 3510 in front grille and (2) truck-lite 4” round amber LED strobes at rear
· Four (4) ECCO model #EW2451 – square LED work lamp with nine (9) 3-watt LED flood beams – measuring 5.2” H x 4.3” W x 3.3” D. Includes black housing & full 360 degree rotation – with on/off switch on light. Also wired into the dash mount switch
· Placard – “work light”
· Furnish and install READING – (3) bar – 50” wide – bolt – on roof mounted ladder rack for enclosed service bodies – including ladder guides. Capacity – 350# evenly distributed powder coat white
· Furnish & install product # FS2797CH – chrome plated cast aluminum large folding step – 7 ¼” x 6 ¾” – conforms to NFPA standards – installed three each side at rear & one each side at front of body to help load ladders, etc from front of body
· Furnish & install # B239918C – 13” x ½” chrome grab handle. (1) each side at rear and (1) each side at front
· Furnish & install false floor in work cab to hold 2 meter and 3 meter survey rods
· Curt #15445 – Class V frame mount hitch – with 2” receiver – 17,000 #WC – 2550# TW
· Hoppy - #40959 – 7 way (flat pin) – 4 way (flat pin) combined trailer receptacle. Includes mounting bracket
· Install OEM factory supplied camera – wiring included. Mount camera to back of unit, includes testing
· Incorporate Spray liner inside cargo area including floor, 4” up each side & front bulkhead, rear bumper, lower 4” of exterior panel doors & complete rear of body from rear doors down
· Include one (1) PR READING logo mudflaps – for DW service body – black
· Generate certification/alteration label and or complete the MSO when applicable
· Generate a weight slip for completed unit
· All required documentation for the finished unit is to be shipped to customer via UPS ground
· Furnish (4) additional dome lights – LED – 5.5” in cargo area wired to existing switch inside right rear door
· Spray liner complete raised portion of spacemaster roof to protect roof from ladders etc
4. DELIVERABLES
4.1 Install Classic 2 Reading Body’s onto F-450’s, complete custom installation of all shelves, drawer, cargo roof racks and other items as listed above.
5. SECURITY REQUIREMENTS
The Certification and Accreditation (C&A) requirements of clause 48 CFR 1352.239-72 do not apply, and thus a Security Accreditation Package is not required.
Page - 2
File details come from the government source that posted it. Updated .