2-Addendum 1 0011-081525 City Hall HVAC Construction Management complete.pdf

PDF 9 MB Posted

Attached to
City Hall HVAC Construction Management State and local contract opportunity
Solicitation number
RFP0011-081525
Issued by
Hillsborough County, New Hampshire

About this file

This document is an Addendum for Request for Proposal (RFP) 0011-081525 issued by the City of Nashua Purchasing Department for City Hall HVAC Construction Management. The addendum, dated August 8, 2025, includes responses to questions from potential bidders and modifies the original RFP. The project involves HVAC construction management for the City Hall, with a completion date goal of December 31, 2025. The current HVAC system includes an HO Smith boiler and a mix of Mitsubishi, Carrier, and Trane climate control equipment. A pre-bid meeting was held on July 30, 2025, with multiple construction and mechanical firms in attendance.

The project is fully funded, though the specific budget is to be determined. The scope includes specifying new boilers, obtaining three quotes for equipment and subcontractors, and potentially addressing asbestos-containing materials identified in a partial assessment. The City's energy manager will handle rebates, and bidders are expected to provide vendor descriptions, project teams, and detailed estimates at different design stages. The project may involve renovations to flooring, black foam pipe sealer in basement areas, and potential modifications to fire alarm and sprinkler systems. A previous asbestos survey revealed asbestos-containing materials in some areas, including floor tiles, pipe insulation, and exterior window glazing, which will need to be addressed according to state and federal regulations.

View the file

Other files for this state and local contract opportunity

Other files attached to City Hall HVAC Construction Management, newest first.
File Type Posted
1-RFP0011-081525 City Hall HVAC Construction Management.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

City of Nashua Purchasing Department

Administrative Services Division 229 Main Street - Nashua, NH 03060

229 Main Street • Nashua, New Hampshire 03061 • Phone (603) 589-3330 • Fax (603) 589-3233

(603) 589-3330 Fax (603) 594-3233

Addendum 1

RFP 0011-081525 City Hall HVAC Construction Management

August 8, 2025

Information included in this document becomes a part of the original RFP

If you are submitting a paper bid, please sign below to indicate receipt of this additional information and include this page with your bid submittal. If you are submitting a proposal via Bonfire please be sure to acknowledge the addendum on the website before submitting your proposal.

Addendum 1 is being issued to modify the bidding documents to include questions and answers received from potential bidders with the initial RFP

All other aspects of the original document remain the same.

Please sign and return this page with your submitted proposal. Failure to acknowledge the addendum will result in the bid submittal being disqualified.

I acknowledge that Addendum 1 has been received and incorporated into bid submittal for RFP 0011-081525 City Hall HVAC Construction Management.

Authorized Signature

Date

Name of Firm

Addendum 1

RFP 0011-081525 City Hall HVAC Construction Management

Questions and Answers

Question Answer

1. Do you have a budget for the project? The project is fully funded and the budget is tbd

2. What is the current brand(s) used for the system? HO Smith boiler and a mix of Mitsubishi, Carrier and Trane providing climate control

3. Is there other equipment on gas that will require updating besides the boilers?

Not that we’re aware of at this time

4. Is this underground or at the meter? At the meter

5. Will you spec the boilers? Yes.

6. When you say you have 3 prices, do you mean you will have 3 mfrs prices?

Three quotes need to be obtained for equipment and any subcontractor.

7. Do you know if there was a hazardous assessment done? Yes. There is a partial assessment that is attached. Further testing may be required.

8. What is the completion date goal? December 31, 2025

9. Are there any subs that worked in the building in the past that we should be aware of? Is there a rigging company?

There is no rigging company. Viking Controls and Denron Hall have worked in the building.

10. Will we be able to look at the existing equipment Yes

11. Are fire alarm modifications part of this scope of work? TBD during design. It is not anticipated.

12. Are sprinkler modifications part of this scope of work? TBD during design. It is not anticipated.

13. Is the roof under warranty? If yes, is there a preferred roofing contractor that we need to use to maintain the warranty of the roof?

There is no preferred contractor or warranty.

14. When we provide the “Vendor Description and Project Team”, (Pg. 9, Section - Proposal Document List) are you looking for the vendors that we will source the boilers from, or for the sub-contractor team we plan to use for the project – Mechanical, Electrical, etc.?

Both

15. For the Project Team (Pg. 9, Section - Proposal Document List), are you looking for our internal company Project Team including Project Executive, Estimator, Project Manager, and Project Superintendent, or our preferred sub-contractors that we plan to include in the project team?

The internal team to your company

16. Which companies attended the pre-bid meeting? See the attached pre-bid meeting attendance list.

17. Please provide clarification on the Pg. 10, Section - Scope and Pricing of Services, where it says, “Provide three estimates at the completion of schematic design, design development, construction documents stages.” Will these 3 estimates be pricing from 3 separate mechanical contractors, or 3 prices for the boiler equipment that will be specified in the design documents?

It will be pricing for the whole project. Equipment and labor for the install.

18. Should we plan to engage the NHSaves program for boiler rebates or will the City of Nashua file for these rebates?

No. The City’s energy manager will handle the rebates.

Mr. Ross Dugas, Safety /Loss Prevention Analyst

City of Nashua

229 Main Street

Nashua, New Hampshire 03062-2019

Re: Pre-Renovation Asbestos Inspection, Nashua City Hall

Motor Vehicles Dept., Tax Offices, Assessing Dept., & City Clerk

TLG Job Number 20-18266

Prepared By: Stephen McPherson

Report Date: August n, 2020

The

LAWSON

GROUP

Thinking. Without the Box.

Introduction:

On July 28, 2020, Stephen McPherson, Senior Safety & Health Professional with The Lawson Group (TLG), performed a Limited Pre-Renovation Survey for Asbestos Containing Building Materials (ACM/ACBM) and Lead Based Paint (LBP). The Survey was performed at City of Nashua, Nashua City Hall in the following Departments:

• Motor Vehicle & Tax Office

• Assessing

• City Clerk

The laboratory results for the bulk Asbestos samples are included in Appendix Al, and All. Paint Sample laboratory results are in Appendix B.

Discussion:

Asbestos Survey:

The survey was conducted to document the presence of ACM in Ceiling Tiles that may be impacted during scheduled renovations/demolition of the building. Based on the analytical results for the bulk samples collected and our visual observations, ACM was identified in some of the building materials sampled in the Motor Vehicle, Tax Office, and the Assessing Departments. ACM was not identified in the City Clerk Area.

During the survey, 48 samples were collected following guidelines in the Asbestos Hazard Emergency Response Act (AHERA), however, the survey was performed to comply with the Environmental Protection Agency (EPA), National Emission Standards for Hazardous Air Pollutants (NESHAP), and State of New Hampshire Department of Environmental Services (NH DES) Env-A 1804.01 regulations, which require a thorough inspection for ACBM be conducted prior to any demolition/renovation of a facility.

Samples were delivered to a National Voluntary Laboratory Accreditation Program (NVLAP)-accredited laboratory for the analysis of bulk Asbestos samples by PLM. According to Federal and State regulations, materials containing greater than one percent (> 1%) Asbestos by dry weight are Asbestos containing.

The survey was performed at select departments in Nashua City Hall in Nashua NH; TLG performed only limited exploratory demolition in representative locations to identify areas where hidden ACM may be present. Since not all these types of locations could be accessed, additional ACM may be present in these areas, and care should be utilized when opening wall or ceiling chases.

Mr. Ross Dugas, Safety I Loss Prevention Analyst - City of Nashua Re: Pre-Renovation Asbestos Inspection, Nashua City Hall, Page 1

City Clerk Area

Non-Asbestos Materials:

Asbestos was not detected in the following materials that were sampled and analyzed during the survey.

Material General Location

Pipe and Fitting Insulation

Ceiling Tiles Throughout

Cove base and adhesive

Gypsum Wall Board/Joint Compound

The survey was performed from the interior of the building which would be impacted by scheduled renovation of the City Hall Department. TLG did not disassemble mechanical, plumbing, or electrical components or perform inspections of all wall cavities or below grade. If a suspect material not identified and sampled as part of this survey is found, it should be assumed to be Asbestos containing until further sampling and analysis can be performed and will have to be removed in accordance with State and Federal Asbestos Regulations prior to renovation of the structure.

ACM must be abated in accordance with the State of New Hampshire and Federal requirements prior to activities such as renovation or demolition, which may directly disturb these materials.

Mr. Ross Dugas, Safety I Loss Prevention Analyst - City of Nashua Re: Pre-Renovation Asbestos Inspection, Nashua City Hall, Page 4

Asbestos Bulk Analysis Report

Client:

Report Number:

Project/Test Address:

Client Number:

Reported Date:

Received Date:

Analyzed Date:

The Scott Lawson Group Ltd. 07/30/2020

201023

08/03/2020

20-07-04404

7469 Whitepine Rd

Telephone: 800.347.4010

Richmond, VA 23237

Environmental Hazards Services, L.L.C.

20-18066; City Hall Renovation

Laboratory Results Fax Number:

603-228-3871

20 Chenell Drive Concord, NH 03301

07/31/2020

Layer Type AsbestosClient Sample Number

Other Materials

Lab Gross DescriptionLab Sample Number

Off White Granular;

Homogeneous

20-07-04404-001 B01A 100% Non-FibrousNAD

Off White Granular;

Homogeneous

20-07-04404-002 B01B 100% Non-FibrousNAD

Brown Beige Adhesive;

Homogeneous

20-07-04404-003 B02A 100% Non-FibrousNAD

Brown Beige Adhesive;

Homogeneous

20-07-04404-004 B02B 100% Non-FibrousNAD

White Granular;

Homogeneous

20-07-04404-005 B03A 100% Non-FibrousNAD

1 of 5Page

White Granular;

Homogeneous

20-07-04404-006 B03B 100% Non-FibrousNAD

Gray Granular;

Homogeneous

20-07-04404-007 B04A 2% Cellulose 98% Non-Fibrous

NAD

Gray Granular;

Homogeneous

20-07-04404-008 B04B 2% Cellulose 98% Non-Fibrous

NAD

White Paint; Gray Fibrous;

Inhomogeneous

20-07-04404-009 B05A 55% Cellulose 25% Fibrous Glass 20% Non-Fibrous

NAD

White Paint; Gray Fibrous;

Inhomogeneous

20-07-04404-010 B05B 55% Cellulose 25% Fibrous Glass 20% Non-Fibrous

NAD

Gray Powdery; Brown Fibrous; Inhomogeneous

20-07-04404-011 B06A 32% Cellulose 2% Fibrous Glass 66% Non-Fibrous

NAD

Gray Powdery; Brown Fibrous; Inhomogeneous

20-07-04404-012 B06B 32% Cellulose 2% Fibrous Glass 66% Non-Fibrous

NAD

Tan Fibrous; Black Tar like Fibrous; Inhomogeneous

20-07-04404-013 B07 82% Cellulose 14% Non-Fibrous

4% Chrysotile

Chrysotile present throughout sample.

4%Total Asbestos:

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:201023 20-07-04404

20-18066; City Hall Renovation

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample Number

2 of 5Page

Gray Fibrous;

Homogeneous

20-07-04404-014 B08 25% Cellulose 39% Non-Fibrous

36% Chrysotile

36%Total Asbestos:

Gray/Tan Fibrous;

Inhomogeneous

20-07-04404-015 B09 35% Cellulose 15% Non-Fibrous

50% Chrysotile

Chrysotile present throughout sample.

50%Total Asbestos:

Gray Fibrous;

Homogeneous

20-07-04404-016 B10 15% Cellulose 27% Non-Fibrous

58% Chrysotile

58%Total Asbestos:

Tan Black; Homogeneous20-07-04404-017A B11 86% Non-FibrousTar 14% Chrysotile

14%Total Asbestos:

Gray Granular;

Homogeneous

20-07-04404-017B B11 100% Non-FibrousPlaster NAD

White Paint; Brown Fibrous; Inhomogeneous

20-07-04404-018 B12A 92% Cellulose 8% Non-Fibrous

NAD

White Paint; Brown Fibrous; Inhomogeneous

20-07-04404-019 B12B 92% Cellulose 8% Non-Fibrous

NAD

Gray Powdery; Brown Fibrous; Inhomogeneous

20-07-04404-020 B13A 18% Cellulose 4% Fibrous Glass 78% Non-Fibrous

NAD

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:201023 20-07-04404

20-18066; City Hall Renovation

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample

3 of 5Page

Gray Powdery; Brown Fibrous; Inhomogeneous

20-07-04404-021 B13B 18% Cellulose 4% Fibrous Glass 78% Non-Fibrous

NAD

Gray Powdery; Brown Fibrous; Inhomogeneous

20-07-04404-022 B14A 20% Cellulose 4% Fibrous Glass 76% Non-Fibrous

NAD

Gray Powdery; Brown Fibrous; Inhomogeneous

20-07-04404-023 B14B 3% Cellulose 4% Fibrous Glass 93% Non-Fibrous

NAD

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:201023 20-07-04404

20-18066; City Hall Renovation

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample

4 of 5Page

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:201023 20-07-04404

20-18066; City Hall Renovation

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample Number

Missy Kanode

1% Asbestos

Analyst:

Reporting Limit:

Method:

QC Blank:

QC Sample:

Sami Hosn

EPA Method 600/R-93/116, EPA Method 600/M4-82-020

QA/QC Clerk

Reviewed By Authorized Signatory:

48-M12017-2

SRM 1866 Fiberglass

NAD = no asbestos detectedLEGEND:

The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0 VELAP 460172. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.

Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy (TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.

400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.

* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.

5 of 5Page

Asbestos Bulk

Client:

Report Number:

Project/Test Address:

Client Number:

Reported Date:

Received Date:

Analyzed Date:

The Scott Lawson Group Ltd. 07/30/2020

201023

08/04/2020

20-07-04408

7469 Whitepine Rd

Telephone: 800.347.4010

Richmond, VA 23237

Environmental Hazards Services, L.L.C.

20-18066; City Hall Renovations; City Clerk

Laboratory Results Fax Number:

603-228-3871

20 Chenell Drive Concord, NH 03301

07/30/2020

Layer Type AsbestosClient Sample Number

Other Materials

Lab Gross DescriptionLab Sample Number

Beige Powdery; Fibrous;

Homogeneous

20-07-04408-001 B01A 20% Cellulose 5% Fibrous Glass 75% Non-Fibrous

NAD

Beige Powdery; Fibrous;

Homogeneous

20-07-04408-002 B01B 15% Cellulose 10% Fibrous Glass 75% Non-Fibrous

NAD

White Powdery; Chalky;

Brown Fibrous;

Inhomogeneous

20-07-04408-003 B02A 18% Cellulose 82% Non-Fibrous

NAD

White Powdery;

Homogeneous

20-07-04408-004 B02B 3% Cellulose 2% Fibrous Glass 95% Non-Fibrous

NAD

Gray Rubbery Vinyl-Like;

Homogeneous

20-07-04408-005 B03 100% Non-FibrousNAD

1 of 3Page

Pale Yellow Pliable Adhesive; Homogeneous

20-07-04408-006 B04 8% Cellulose 92% Non-Fibrous

NAD

Beige Fibrous; White Paint; Homogeneous

20-07-04408-007 B05A 65% Cellulose 20% Fibrous Glass 15% Non-Fibrous

NAD

Beige Fibrous; White Paint; Homogeneous

20-07-04408-008 B05B 65% Cellulose 20% Fibrous Glass 15% Non-Fibrous

NAD

Environmental Hazards Services, L.L.C

Project/Test Address:

Client Number: Report Number:201023 20-07-04408

20-18066; City Hall Renovations; City Clerk

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample

2 of 3Page

Project/Test Address:

Client Number: Report Number:201023 20-07-04408

20-18066; City Hall Renovations; City Clerk

Other Materials

AsbestosLab Sample Number

Layer Type Lab Gross DescriptionClient Sample Number

Missy Kanode

1% Asbestos

Analyst:

Reporting Limit:

Method:

QC Blank:

QC Sample:

Kay Harris

EPA Method 600/R-93/116, EPA Method 600/M4-82-020

QA/QC Clerk

Reviewed By Authorized Signatory:

44-M12018-4

SRM 1866 Fiberglass

NAD = no asbestos detectedLEGEND:

The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Each distinct component in an inhomogeneous sample was analyzed separately and reported as a composite. Results represent the analysis of samples submitted by the client. Sample location, description, area, volume, etc., was provided by the client. This report cannot be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714 NVLAP #101882-0 VELAP 460172. All information concerning sampling location, date, and time can be found on Chain-of-Custody. Environmental Hazards Services, L.L.C. does not perform any sample collection.

Environmental Hazards Services, L.L.C. recommends reanalysis by point count (for more accurate quantification) or Transmission Electron Microscopy (TEM), (for enhanced detection capabilities) for materials regulated by EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by polarized light microscopy (PLM). Both services are available for an additional fee.

400 Point Count Analysis, where noted, performed per EPA Method 600/R-93/116 with a Reporting Limit of 0.25%.

* All California samples analyzed by Polarized Light Microscopy, EPA Method 600/M4-82-020, Dec. 1982.

3 of 3Page

Client:

Project/Test Address:

The Scott Lawson Group Ltd.

7469 Whitepine Rd

Telephone: 800.347.4010 Richmond, VA 23237

Environmental Hazards Services, L.L.C.

20-18266; City of Nashua City Hall

Client Number:

201023

Fax Number:

603-228-3871Laboratory Results

Analyzed Date:

Client Sample Number

Lab Sample Number

Pb (ug/g) ppm

Lead Paint Chip

08/04/2020

07/30/2020

20-07-04409

Reported Date:

Received Date:

Report Number:

20 Chenell Drive Concord, NH 03301

Narrative

ID

08/03/2020

Collection Location % Pb by Wt.

07/28/2020Collection Date:

P0120-07-04409-001 1800 0.18

P0220-07-04409-002 350 0.035

P0320-07-04409-003 29000 2.9

P0420-07-04409-004 400 0.040

Page 2of1

Report Number:

Project/Test Address:

Client Number: 20-07-04409

20-18266; City of Nashua City Hall 201023

Collection LocationClient Sample Number

Lab Sample Number

% Pb by Wt.

Narrative

ID

Pb (ug/g) ppm

Missy Kanode QA/QC Clerk

Analysis Method: EPA SW846 7000B

The HUD lead guidelines for lead paint chips are 0.50% by Weight, 5000 ppm, or 1.0 mg/cm². The Reporting Limit (RL) for samples prepared by ASTM E-1979-17 is 10.0 ug Total Pb. The RL for samples prepared by EPA SW846 3050B is 25.0 ug Total Pb. Paint chip area and results are calculated based on area measurements determined by the client. All internal quality control requirements associated with this batch were met, unless otherwise noted.

LEGEND Pb= lead ug = microgram ppm = parts per million ug/g = micrograms per gram Wt. = weight

Reviewed By Authorized Signatory:

Preparation Method: ASTM E-1979-17

The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the client. Sample location, description, area, etc., was provided by the client. Results reported above in mg/cm3 are calculated based on area supplied by client. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C.

ELLAP Accredtitation through AIHA-LAP, LLC (100420), NY ELAP #11714.

Page 2of2

Addendum_1_0011-081525 City Hall HVAC Construction Management.pdf (p.1-3)
Asbestos Report_MVR, Assessing, Tax, City Clerk.pdf (p.4-28)
20101108_Asbestos Survey_SLGL.pdf (p.29-61)
0011-081525_Pre-Bid Sign In Sheet.pdf (p.62-63)

File details come from the government source that posted it. Updated .