This document is a specification sheet for the FireWorks Incident Management Platform. The FireWorks system provides mass notification, life safety, and incident management capabilities. It includes hardware, software, and networking components to support graphical command and control interfaces across up to 30 client workstations. The system integrates with EDWARDS life safety panels and is also interoperable with third-party equipment. Key features include dynamic event-driven user interfaces across five configurable viewports, facility mapping, live video feeds, audio channels, and remote system access. The document provides detailed specifications for server and workstation hardware, software options including redundant server configurations for up to 50 seats, VESDA aspirated smoke detection interfaces, third-party integration modules, and networking equipment. Ordering information is included for all system components, software licenses, installation and maintenance items.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Abstract of Offers.pdf | ||
| Amendment 0001.pdf | ||
| PreBid Meeting Minutes and Sign in Sheet.pdf | ||
| Questions and Answers - Elkton Replace Fire Alarm 1.pdf | ||
| Updated Wage Determination 8-4-2023.pdf | ||
| Solicitation.pdf | ||
| Wage Determination.pdf | ||
| SF-24 Bid Bond Form.pdf | ||
| Instructions to Bidders.pdf | ||
| Criminal History Check Form.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Page 1 of 8 D A T A S H E E T E85006-0068 Not to be used for installation purposes. Issue 2.3
EDWARDS® Catalog u Incident Management and Annunciation
03.31.22
L I F E S A F E T Y & I N C I D E N T M A N A G E M E N T
FireWorks®
Incident Management Platform
7300-1657:
S3424
COA 6228
Overview FireWorks is an incident management command and control platform that comprises hardware, software, and networking components that together provide a powerful and cohesive Mass Notification and Life Safety solution. Sophisticated networking technology allows it to integrate seamlessly with EDWARDS life safety solutions, yet FireWorks remains fully interoperable with third-party equipment, making it ideal for system upgrades or new installations alike.
FireWorks can automatically trigger programmed responses to facility events, or it can act as an operator interface for manual control. The FireWorks user interface provides a clear, concise, and coordinated view of any situation by presenting information strategically.
Five configurable graphical viewports offer simultaneous insight into different aspects of an incident, while the underlying software dynamically manages content in each viewport based on real-time events and user interaction. Facility maps, live video feeds, audio channels, protocol information, and fingertip control over vital equipment all come together instantly within view of an operator facing events that require solid information and split-second timing.
Supporting every FireWorks workstation is a sophisticated network backbone—strong enough to handle coordinated critical control functions from as many as 30 client workstations and many other devices, yet flexible enough to manage integration with third-party mass notification systems.
Redundant server options eliminate risk of communications breakdowns by providing alternate data paths that regenerate communications in the event of signal loss. FireWorks can operate on an existing local area network, or provide facility access from anywhere in the world via secured Virtual Private Network (VPN) connections.
Standard Features
• Widely listed to prevailing Mass Notification and Life Safety standards
Readily adopted for standalone or remote applications
• Listed for UUKL Graphical FSCS Applications Cost-effective and scalable graphical smoke control station
• Dynamic event-driven user interface Easy-to-follow notification and control protocols
• Software-only standalone versions Cost-effective annunciation where agency listings are not required
• Highly Sensitive Smoke Detector (HSSD) support Full command and control integration with VESDAnet detectors
• FW-FAST Automatic System Configuration Generate interactive floorplans from engineering drawings and EDWARDS SDU files.
• Email event notification to multiple recipients Instant communication with off-site personnel
• Powerful HTTP/HTTPS communication engine Compatible with DRMNS and many other third-party systems
• Password-defined user access and event filtering Control who sees what
• Use native graphic formats to create event maps Import most standard graphic formats—no conversion required
• Multilingual operation Supports English (UK, AUS, and US), Chinese (Simplified and Traditional), French (Canada), Polish, Russian, Spanish, Turkish, Portuguese (Brazil), Arabic and Hebrew
• Real-time Remote Client Access system information from anywhere in the world
• Cybersecurity Hardening While no system can claim 100% protection, Edwards continues to leverage best practices in security testing to ensure protection. Cybersecurity is a constant threat and system hardening will continue beyond this release so you can feel confident now and going forward. The following are highlights of our new cybersecurity enhancements:
• Compliance: RMF with P2P CIA High baseline with 800-53R4 controls
• Penetration Testing: We have utilized external pen testing with APPLUS and internal penetration testing to discover and fix critical vulnerabilities.
• Static Analysis: FireWorks’ code was scanned for CWEs to improve cybersecurity
Page 2 of 8 D A T A S H E E T E85006-0068
FireWorks systems can send certain UL 2572 V1, Technical Category TC1, TC2, TC3 and TC4 outputs to third-party systems by way of the MN-FVPN VoIP, MN-NETRLY4 and/or Signature Series modules. The EDWARDS APS6A and APS10A can be easily configured to support most third-party interfaces.
Flexible Email Messaging
To enhance off-premise notification, FireWorks supports connection to a Simple Mail Transfer Protocol (SMTP) mail server, allowing event information to be emailed.
This provides the ability to get event information automatically, efficiently and inexpensively to the people who need to know about events in facilities.
Email messages can be configured based on individual events, event categories and more.
Certain people can receive all system events, others can receive only alarm conditions, while still others can receive only specific events—the options are easy to configure and also to change.
Valuable Reporting Functions
FireWorks report functionality allows the system administrator or other authorized user to create and retrieve panel reports.
Reports include Panel Status, Disabled Points and Sensitivity. Meanwhile, a full history report generator allows the review of historical panel events.
FireWorks has a versatile Devices Test Report. This report allows for devices that have been tested as part of a Service Group to be included in a National Fire Protection Association (NFPA) Fire Alarm And Signaling Code (NFPA 72) formatted report.
Event Action Viewport:
This screen is used to provide instructions on how to respond to the selected event, and also to acknowl-edge that these instructions have been carried out.
Map Viewport:
This gives the user an overview of the event’s location in the context of its sur-roundings and the en-tire facility.
Browser Viewport:
When the FireWorks work-station is provided with an Internet/network connec-tion, the Browser Viewport can be configured to automatically connect to emergency information sites, network accessible building automation, video streams, and other third-party systems.
Image Viewport:
Displays images relevant to the occurrence. Any event, any device, or any combination of devices and events can retrieve instant graphical information that is relevant to the occurrence and can be understood at a glance.
Event List Viewport:
Upon receipt of a change of state, the event information is displayed in the Event List Viewport. If several events are received, all events are displayed in the Event List viewport and are color-coded by priority.
Each operator can customize the system to have anywhere from two to five viewports visible.
Dynamic Viewports
Application Scalable Third-party Integration
FireWorks is equipped with a powerful HTML/HTTP/HTTPS/XML Command Processor that supports integration for Distributed Recipient Mass Notification Systems (DRMNS) and many other third-party systems. It can also receive information from third-party systems by way of the FW-DARCOM (with Bosch D6600/D6100 option and/or with the MN-NETRLY4 input/output modules.
Powerful Network Capabilities
• Up to 15 Graphical Command/Control WorkStations with Non-Redundant Server option
• Up to 30 Graphical Command/Control WorkStations with Redundant Server option
• Up to 15 concurrent Text-Only Remote Clients
• Up to 25 EST4 panel networks
• Up to 125 EST3(X) panel networks
• Up to 800 MN-FVPN Voice over Internet Protocol (VoIP) or MN-NETRLY4 Input/Output modules
• Up to 1,000 iO Series panel connections via FW-IPMON 1000 and FW-DARCOM with up to 1000 points per system for up to 1,000,000 points from iO systems
• DACR accounts with FW-DARCOM and Bosch D6600/6100 supports 3,200 Dial-up or 500 IP Contact ID accounts
• Up to 20 VESDAnet networks with each network having up to 61 detectors in life safety mode (1,220 detectors) or 100 detectors in process monitoring mode (2,000 detectors) (Non-UL system may exceed 20 HLI/
FW-HSSX1)
Page 3 of 8 D A T A S H E E T E85006-0068
• Utilizes Microsoft configuration requirements
• System will support up to 15 client workstations
• All connections are supervised and will post faults across the network
• The network must have a dedicated VLAN with priority signaling
• Network switches must have UPS power
• System will support up to 30 client workstations
• System will have Primary, Backup, and Witness servers with automatic transfer from Primary to Backup
• Servers require a quorum to operate
• All connections are supervised and will post faults across the network
• The network must have a dedicated VLAN with priority signaling
• Network switches must have UPS power
Redundant Network: up to 30 Client Workstations
Non-redundant Network: up to 15 Client Workstations
Example UL Listed Mass Notification: Scalable Third-party Integration
FireWorks Networks Topologies
• Large network capacity for global and enterprise-wide connectivity
• Compatible with third-party networks
• UL/ULC Listed for Mass Notification
• Easy-to-navigate event-driven viewport display
• Software-only versions do not require UL listed hardware
• Internet/WAN connectivity
• Monitor and control for single or multi-line networks
• HTTP/HTTPS communications engine
• Automatic email notification to multiple recipients
• Context-sensitive event action instructions
• Create event maps with standard graphic formats
• Digital Alarm Receiver connectivity
EDWARDS Control Panels Third-party Control Panels
Non-dedicated Network
FireWorks Client Workstation
Ethernet Switch
DACT
T R A N S M I T T E R
DACR
R E C I E V E R
VOIP
V O I C E O V E R I P
VOIP
V O I C E O V E R I P
DACT
T R A N S M I T T E R
Local Operations Console
VOIP
V O I C E O V E R I P
VOIP
V O I C E O V E R I P
Ethernet Switch
FireWorks Server
EST4 Panel Network 2
Client Workstation 1 Client Workstation 2
Backup Server
Witness Server
Client Workstation 3
Primary Server
EST4 Panel Network 1 EST4 Panel Network 3
Ethernet Network (Class X)
Optional VESDAnet HSSD Interfaces
Client Workstation 1 Client Workstation 2
Client Workstation X Client Workstation 3
System Server
EST4 Panel 1
EST4 Panel 2
EST4 Panel 3
Ethernet Network (Class B)
MN-COM1S
Optional VESDAnet HSSD Interface
MN-COM1S
Optional VESDAnet HSSD Interface
MN-COM1S
TO PRIMARY SVR
4-FWAL
TO SERVER
MN-COM1S
TO SERVER
4-FWAL
TO SERVER
4-FWAL
TO SERVER
4-FWAL
TO PRIMARY SVR
4-FWAL
TO BACKUP SVR
4-FWAL
TO PRIMARY SVR
4-FWAL
TO BACKUP SVR
4-FWAL
TO PRIMARY SVR
4-FWAL
TO BACKUP SVR
MN-COM1S
TO BACKUP SVR
High Power Speaker Array (not UL Listed)
VOIP
V O I C E O V E R I P
Page 4 of 8 D A T A S H E E T E85006-0068
Network Options
FW-FAST: Automatic System Configuration
FireWorks Assimilation Systems Technology can significantly reduce the time and expense of programming or modifying a FireWorks system database. This unique and powerful option reads properly formatted AutoCAD® and EDWARDS System Definition Utility (SDU) files to automatically create floorplans with device locations, and panel renderings with pseudo point touch-sensitive areas. Floorplans and panel renderings can then easily be inserted into the FireWorks system.
Note: Only Available for EST4, EST3, and EST3X.
FW-HSSX1: Aspirated Detection Interface
FireWorks Highly Sensitive Smoke Detector (HSSD) interface provides UL Listed/FM Approved digital command/control integration with Xtralis VESDA® Series smoke detectors for very early fire detection. FireWorks can respond to individual sector/pipe conditions, detector events, as well as minor and major faults across 20 VESDA nodes encompassing as many as 2,000 VESDA detectors. It can also reset and perform certain other control functions of the VESDAnet detectors.
FW-DARCOM: FX Conventional and Third-Party Interoperability
This option allows for a FireWorks system to support Digital Alarm Communicator Receiver (DACR) operation. The DACR can be any Bosch® D6600/D6100 DACR that can receive Security Industry Association (SIA) Contact ID or 4/2, or the cost-effective FW- IPMON1000 option.
FW-IPMON1000: Life Safety Integration
When used in conjunction with FW-DARCOM software, this option supports digital connection to up to a total of 1,000 EDWARDS iO and FX Series control panels for receive-only Contact ID operation.
Each individual zone or addressable device can display on the FireWorks system.
Remote Clients: Global VPN Communications
FireWorks systems support an optional real-time Remote Client remote read-only text viewing feature that can be accessed from anywhere in the world via a secured Virtual Private Network (VPN) connection, or local network connection. Remote Client events mirror the FireWorks system Event List and Event Action viewports. These events are prioritized and color-coded for easy identification by type and source. Events may also be filtered at the Remote Client, and sound files can be added per alarm, supervisory, trouble or monitor event category.
Any number of remote clients can be deployed by FireWorks. The number of concurrent connections possible is determined by the software license option. The Remote Client can also run many reports for the remote workstation and print them to a local printer or output them to a .csv file.
Hardware Options
Workstations
The FireWorks FW-UL6WW10 Workstation is a UL 864/ULC S527 Listed and hardened industrial workstation that can be used for any Workstation or Witness Server application.
FW-UL6WW10 is also UL 864 UUKL/UUKL7 listed for graphical FSCS functionality. The FW-UL6WW10 cannot be used as a Redundant or Non-Redundant System Server.
The FW-UL6WW10 has the following specifications:
• i7 4770S processor
• 3.9 GHz
• 8 MB Cache
• QPI speed of 5 GT/S
• 4 core, multi-threaded to 8
• 32 GB RAM
• Standard RAID 1 (dual) 1 TB Solid State Drives
• 2 Network Interface Ports
Servers
The FireWorks FW-UL6SW10 Server is a UL 864/ULC S527 Listed hardened industrial workstation that can be used for any FireWorks—Server, Workstation or Witness Server. FW-UL6SW10 is also UL 864 UUKL/UUKL7 listed for graphical FSCS functionality. The FW-UL6SW10 has the following specifications:
• Dual Xeon capable
• Standard single processor Xeon 2680
• 3.6 GHz
• QPI speed of 8 GT/S
• 10 core, multi-threaded to 20
• 25 MB Cache
• 128 GB RAM per processor
• Standard RAID 1 (dual) 1 TB Solid State Drives
• Standard Hot-swappable dual power supplies
• 4 Network Interface Ports
Monitors
The FireWorks solution family offers 2 UL/ULC Listed/FM Approved monitor options, 22" and 42" touchscreens. Each FireWorks Workstation can support multiple monitors.
The FW-22LCDWTS is a touch screen unit with:
• Up to 1920 x 1080 video
• Built-in speakers
• DVI/VGA input
• Desktop mounting
The FW-42LCDWTS is a touch screen unit with:
• Up to 1920 x 1080 video
• Built-in speakers
• DVI/VGA input
• Single horizontal wall-mounting option
Page 5 of 8 D A T A S H E E T E85006-0068
• CAN/ULC-S527-11 Standard for Control Units for Fire Alarm Systems, 2nd edition
• CAN/ULC-S559-04 Standard for Equipment for Fire Signal Receiving Centres and Systems, 1st edition
• CSA C22.1-12 Canadian Electrical Code, Part 1
• UL 864 Standard for Control Units and Accessories for Fire Alarm Systems, 10th edition
• UL 2017 Standard for General- Purpose Signaling Devices and Systems, 2nd edition
• UL 2572 Standard for Mass Notification Systems, 1st edition
• NFPA 11 Standard for Low- Expansion Foam Systems, 2010 edition
• NFPA 11A Standard for Medium- and High-Expansion Foam Systems, 2010 edition
• UL 864 UUKL/UUKL7 Graphical Firefighter Smoke Control Station
• UL 864 BSIU Building System Information Unit (FW-UL6W only)
• NFPA 12 Standard on Carbon Dioxide Extinguishing Systems, 2011 edition
• NFPA 12A Standard on Halon 1301 Fire Extinguishing Systems, 2009 edition
• NFPA 12B Standard on Halogenated Fire Extinguishing Agent Systems Halon 1211
• NFPA 13 Standard for the Installation of Sprinkler Systems, 2013 edition
• NFPA 15 Standard for Water Spray Fixed Systems for Fire Protection, 2012 edition
• NFPA 16 Standard for the Installation of Foam-Water Sprinkler and Foam-
Water Spray Systems, 2011 edition
• NFPA 17 Standard for Dry Chemical Extinguishing Systems, 2013 edition
• NFPA 17A Standard for Wet Chemical Extinguishing Systems, 2013 edition
• NFPA 70 National Electrical Code
• NFPA 72 National Fire Alarm Signaling Code
• NFPA 2001 Standard on Clean Agent Fire Extinguishing Systems, 2012 edition
• UL 2572 security and data protection
• For UL 2572 first edition applications only
• Approved Security Function for FIPS PUB 140-2: No encryption employed
• Communication Security: Level 1
• Stored Data Security: Level 0
• Access Control Security: Level 2
• Physical Security: Level 1
• Audit Control: Not provided
• FM Approved
• FDNY
• CSFM
Agency Listing The UL6W, UL6WW10, UL6S, UL6SW10 have been investigated against, and found to be in compliance with, the following standards:
MN-FNS8C2F3 Managed Ethernet Switch
DATA SHEET E85010-0153
FireWorks can operate on dedicated (recommended) or non-dedicated Ethernet networks.
EDWARDS offers one of the most robust and powerful UL/ULC Listed/FM Approved Managed Ethernet Networking solutions available. MN-FNS Series Managed Ethernet Solutions are powered by Cisco® technologies. Layer 2 and Layer 3 switches/ routers are available, along with interface modules that support single or multimode fiber optic media.
Class B, Class X, Mesh and Hybrid topologies are fully supported.
UL/ULC Listed/FM Approved MN-FVPN Voice over Internet Protocol (VoIP), MN-NETRLY4 input/ output and MN-COM1S Communication Modules are all supported by the FireWorks platforms.
Network Accessories
MN-FVPN
Data Sheet E85010-0143
MN-NETRLY4
Data Sheet E85010-0149
MN-COM1S
Data Sheet E85010-0155
FireWorks, along with the EST3(X)/ EST4, can control the crystal-clear and powerful HyperSpike High and Medium Power Speaker Arrays.
See DATA SHEET E85001-0637 for more information.
Always consult the latest Agency Standards, Consensus Standards/Codes and with the Local Authority Having Jurisdiction for system application and installation requirements.
See Ordering Information List for FireWorks Hardware Accessory information and descriptions.
Page 6 of 8 D A T A S H E E T E85006-0068
Ordering Information System Software
FW-CGS
Standalone FireWorks Color Graphics Software PIN letter. Allows full 5 view port display.
Includes FW-FIREKEYUSB. No common control.
FW-CGSUL
Standalone FireWorks Color Graphics Software PIN letter. Allows full 5 view port display.
Includes FW-FIREKEYUSB. With common control.
FW-NCZZFP
Non-Redundant Server Client license. One Hasp PIN Code. Requires one new FW-CGSUL base package, ordered separately.
FW-NSZ5FP
5 seat non-redundant server. One Hasp PIN codes for server only. Order Workstation Client licenses separately. Requires one new FW-CGSUL base package, ordered separately.
FW-NS15FP
15 seat non-redundant server. One Hasp PIN code for server only. Order Workstation Client licenses separately. Requires one new FW-CGSUL base package, ordered separately.
FW-RCZZFP
Redundant Server Client license. Requires one new FW-CGSUL base package, ordered separately.
FW-RSZ5FP
5 seat redundant server for new installations.
Two Hasp PIN codes, two Microsoft SQL licenses for servers only. Order Workstation Client licenses separately. Requires one new FW-CGSUL base package, ordered separately.
FW-RS15FP
15 seat redundant server for new installations.
Two Hasp PIN codes, and two Microsoft SQL licenses for servers only. Order Workstation Client licenses separately. Requires one new FW-CGSUL base package, ordered separately.
FW-RS25FP
25 seat redundant server for new installations.
Two Hasp PIN codes and two Microsoft SQL licenses for servers only. Order Workstation Client licenses separately. Requires one new FW-CGSUL base package, ordered separately.
FW-RS50FP
30 seat redundant server for new installations kit.
Two Hasp PIN codes and two Microsoft SQL licenses for servers only. Order Workstation Client licenses separately. Requires one new FW-CGSUL base package, ordered separately.
Upgrade Software
FW-NCZZWP
Upgrade existing FW-CGSUL license to Non-Redundant Client license. One Hasp PIN Code.
FW-NCZZXP
Upgrade existing FW-CGS license to Non-Redundant Client license. One Hasp PIN Code. Includes one FW-CGSUL base package.
FW-RCZZUP
Upgrade existing Non-Redundant Server Client to Redundant Server Client upgrade. One Hasp PIN code.
FW-RCZZWP
Upgrade existing FW-CGSUL license to Redundant Server Client license. One Hasp PIN Code.
FW-RSZ5UP
Upgrade existing 5 Seat non-redundant server to 5 seat redundant server cluster. Two Hasp PIN codes and two Microsoft SQL licenses for servers only. Order Workstation Client licenses separately.
FW-RS15UP
Upgrade existing 15 Seat non-redundant server to 15 seat redundant server cluster. Two Hasp PIN codes and two Microsoft SQL licenses for servers only. Order Workstation Client licenses separately.
FW-SQL5UP
Upgrading FireWorks Redundant system from existing 5 seat SQL to 5 seat SQL 2019
FW-SQL15UP
Upgrading FireWorks Redundant system from existing 15 seat SQL to 15 seat SQL 2019
FireWorks Software - Options
FW-1S One Seat Remote Client.
FW-4S Four Seat Remote Client (Requires FW-1S).
FW-10S Ten Seat Remote Client (Requires FW-1S & FW-4S).
FW-DARCOM
Pin Code for Communication to DACRs and/or
IPMON1000.
FW-FAST
Pin Code for FireWorks Assimilation System Technology (FAST) AutoCAD® reader and panel building option for FireWorks Server or Stand-alone system. Reads AutoCAD ® files and correlates with project SDU to create or update FireWorks database.
FW-HSSD5
Pin Code for Single VESDA HLI Interface software PIN code. Enables connection of one (1) to five (5) VESDA HLI (FW-HSSX1) to FireWorks as nodes. Requires one FW-HSSX1 High Level Interface for each VESDA network if using Stadalone or Non Redundant Server and two if using Redundant FireWorks Servers. Each server must have it’s own separate FW-HSSX1.
FW-HSSD20
Pin Code for Single VESDA HLI Interface software PIN code. Enables connection of one (1) to twenty
(20) VESDA HLI (FW-HSSX1) to FireWorks as nodes.
Requires one FW-HSSX1 High Level Interface for each VESDA network if using Stadalone or Non Redundant Server and two if using Redundant FireWorks Servers.
Each server must have it’s own separate FW-HSSX1.
FW-IPMON1000
Pin Code for IP Monitoring for 1000 connections to iO Series panels. Requires companion software option
FW-DARCOM.
Servers, Workstations
FW-UL6SW10
FireWorks Server or Workstation. Single Xeon processor, 128 GB Server RAM. Windows 10 LTSC Professional OS (64 bit). With RAID1 500GB array (dual drives) and dual power supplies.
FW-UL6WW10
FireWorks Workstation. Single i7 Intel processor. 32 GB RAM. Windows 10 LTSC Professional OS (64 bit) RAID1 configuration with dual 500 GB SSD. Single power supply.
Servers, Workstations Options
FW-HSSX1
FireWorks to VESDA High Level Interface Module with enclosure. Requires FW-HSSD5 or FW-HSSD20 software. UL/ULC for command/control. Maximum 61 VESDA detectors for Life Safety applications or up to 100 VESDA detectors for process control (non-Life Safety) per FW-HSSX1. 24 VDC.
FW-SP4I
Isolated Serial Port card for FW-UL6WW10 Workstations. Provides four serial ports. Cannot be used on FW-UL6S and FW-UL6SW10 Servers.
PT-1S+ System Printer - Desk Top Style.
Page 7 of 8 D A T A S H E E T E85006-0068
Servers, Workstations Installation Accessories
BP1
Blank Panel for 19 inch Enclosure, 1 panel space -
1.75 inch x 19 inch.
BP2
Blank Panel for 19 inch Enclosure, 2 panel spaces -
3.5 inch x 19 inch.
BP3
Blank Panel for 19 inch Enclosure, 3 panel spaces -
5.25 inch x 19 inch.
BP6
Blank Panel for 19 inch Rack /w 2.5 FP spaces, 6 panel spaces - 10.5 inch x 19 inch.
FW-RACKKB
Keyboard Rack mount kit - Black - 2 EIA panel spaces required.
FW-RACKPC Workstation Rack mount kit for FW-UL6 - Black.
MFC-A
Fire Control Accessory, Multi-Function Enclosure, 8" X 14" X 3.5", Red.
RKU-61-24B
19 inch Black Rack Mount Cabinet, 24" deep for FW-UL6SW10 or FW-UL6WW10.
VP-1 Ventilation Panel 1-3/4".
VP-3 Ventilation Panel 3-1/2".
Monitors, Monitor Accessories
FW-22LCDWTS
22" 16:9 LCD 115 Vac 1680x1050 resolution capacitive touch screen with integral speakers. Comes with desk stand cable set and driver disk.
FW-42LCDHMK1 42" wall mount bracket kit - single display, horizontal.
FW-42LCDWTS
42" 16:9 LCD 115 Vac 1920x1080 resolution surface acoustic wave SAW touch screen. Comes with cable set and driver disk. Requires mounting bracket kit.
Network Modules, Accessories
MN-ABPM
Audio Bridge, panel mount - Mounts on MN-BRKT1 or MN-BRKT3.
MN-COM1S
UL 864 Listed FireWorks Communications Ethernet Port, Command & Control. Comes with power and RS232 data cables.
MN-FVPN
Voice Over Internet Protocol (VoIP) encoder/decoder, includes power and audio cable.
MN-NETRLY4
Ethernet controllable multi I/O module. 4 unsupervised inputs & 4 unsupervised outputs. Comes with one
MN-NRKB1.
MN-NRBK1
Replacement mounting bracket with end caps for single
MN-NETRLY4.
MN-NRMP
Mounting plate to allow up to 2 MN-NETRLY4 modules to be mounted on a MN-BRKT1 bracket.
MN-PASM2
Preamp audio supervision module. Provides Form C dry contact for audio or module failure.
MN-TK10
10 Position, 4 pole terminal kit for use with MN-NETRLY4 or MN-FVPN.
Upgrade and Update Kits
FW-UL6WW10UK-9.1
Thumb Drive to upgrade FW-UL6W from Windows 7 to Windows 10
FW-UL6SW10UK-9.1
Thumb Drive to upgrade FW-UL6S from Windows 7 to Windows 10
FW-UL6WW10UD-9.1
Workstation operating system security updates for FW-UL6WW10 (myEddie download required for V9.1)
FW-UL6SW10UD-9.1
Server operating system security updates for FW-UL6SW10 (myEddie download required for V9.1)
Page 8 of 8 D A T A S H E E T E85006-0068
03.31.22
LIFE SAFETY & INCIDENT MANAGEMENT
Contact us
Phone: 800-655-4497 (Option 4) Email: edwards.fire@carrier.com Website: edwardsfiresafety.com
8985 Town Center Pkwy Bradenton, FL 34202
©2022 Carrier All Rights Reserved.
mailto:edwards.fire%40carrier.com?subject= https://www.edwardsfiresafety.com
File details come from the government source that posted it. Updated .