E-Unit_Roof_Drawings.pdf
PDF 2 MB Posted
- Attached to
- Replace E-Unit Inmate Housing Roof Federal contract opportunity
- Solicitation number
- 15B41520Q00000008
About this file
This solicitation package seeks proposals to replace the roof on an inmate housing unit at the Federal Correctional Institution in Waseca, Minnesota. The Department of Justice Bureau of Prisons is requesting roof replacement services including removal of the existing roofing system, installation of new insulation and roofing membrane, repair of any damaged brick, and provision of a 20-year system warranty. Proposals are due by January 15, 2023 with work to be completed within 120 calendar days of award. The incumbent contractor is responsible for disposing of the existing rock ballast and inspecting drain liters to identify any needing replacement.
Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 15B41520Q00000008 Pre-Bid Site Visit Meeting.pdf | ||
| Wage_Determination_MN_20190100.pdf | ||
| Example_Cost_Breakdown.docx | DOCX document | |
| RFQ_15B41520Q00000008.pdf | ||
| BP_A0660_Criminal_History_Check.pdf | ||
| Instructions_to_Offerors_15B41520Q00000008.pdf | ||
| E-Unit_Roof_Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FCI WASECA
LAYOUT
C -U
N
IT
U
PP
ER
F
LO
O
R
AutoCAD SHX Text
S.HUFFORD
AutoCAD SHX Text 11/1/2018
AutoCAD SHX Text
AutoCAD SHX Text 4C6K
AutoCAD SHX Text
AREA TO BE
AutoCAD SHX Text
RENOVATED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RENOVATION
AutoCAD SHX Text 10,000
AutoCAD SHX Text
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
FREEZER
AutoCAD SHX Text
LOCATED WITHIN THE SECURE PERIMETER
AutoCAD SHX Text
SEE SHEET 4 ACM
AutoCAD SHX Text
ROOF MEASUREMENTS
AutoCAD SHX Text
ROOF PENETRATIONS
AutoCAD SHX Text
ACM
AutoCAD SHX Text
ANCHORS
AutoCAD SHX Text
ANCHOR LOCATIONS
AutoCAD SHX Text
EDPM
AutoCAD SHX Text
CURB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
COVERSHEET
AutoCAD SHX Text
PROJECT 4C6K 19 REPLACE E-UNIT ROOF
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
AutoCAD SHX Text
CURRENT CONDITIONS
AutoCAD SHX Text bop01832 Text Box Approved for Bidding
AutoCAD SHX Text 2019 Sq.Ft.
AutoCAD SHX Text 3044 Sq.Ft.
AutoCAD SHX Text 4563 Sq.Ft.
AutoCAD SHX Text
APP/1.5" BALLASTED ROCK
AutoCAD SHX Text
APP/1.5" BALLASTED ROCK
AutoCAD SHX Text 2019 Sq.Ft.
AutoCAD SHX Text 3044 Sq.Ft.
AutoCAD SHX Text 4563 Sq.Ft.
AutoCAD SHX Text
APP/1.5" BALLASTED ROCK
AutoCAD SHX Text
S.HUFFORD
AutoCAD SHX Text 11/1/2018
AutoCAD SHX Text
AutoCAD SHX Text 4C6K
AutoCAD SHX Text
ROOF MEASUREMENTS
ROOF MEASUREMENTS
5 STEP LADDER-UP
AutoCAD SHX Text
PAVERS
AutoCAD SHX Text
10 STEP LADDER-UP
AutoCAD SHX Text
5 STEP LADDER-UP
AutoCAD SHX Text
PAVERS
AutoCAD SHX Text
PAVERS
AutoCAD SHX Text
S.HUFFORD
AutoCAD SHX Text 11/1/2018
AutoCAD SHX Text
AutoCAD SHX Text 4C6K
AutoCAD SHX Text
ROOF ACCESS
AutoCAD SHX Text
VENT
AutoCAD SHX Text
CURB
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
DRAIN LITER
AutoCAD SHX Text
NOTE: THIS PENETRATION NO LONGER IN USE REMOVE.
AutoCAD SHX Text
DRAIN LITER
AutoCAD SHX Text NOTE: : ALL DRAIN LITERS ARE 4". DURING PREPARATION PHASE THESE ARE TO BE INSPECTED BY COR TO IDENTIFY IF REPLACEMENT IS REQUIRED.
AutoCAD SHX Text
ROOF PENETRATIONS
AutoCAD SHX Text
VENT
AutoCAD SHX Text
ROOF PENETRATIONS
S.HUFFORD
AutoCAD SHX Text 11/1/2018
AutoCAD SHX Text
AutoCAD SHX Text 4C6K
AutoCAD SHX Text ACM LOCATION AND REMOVAL 5% CHRYSOTILE NOTED ON ACM FIELD TESTING LOCATION #5 IN MARCH 2018 FOR SILVER COATING ON METAL FLASHING. ALL OTHER FIELD TESTS ARE NEGATIVE FOR ACM. CONTRACTOR WILL BE RESPONSIBLE FOR REMOVAL OF ACM. CONTRACTOR MUST PROVIDE A MANIFEST WITH AMOUNTS TOTALS TO THE COR UPON DISPOSAL OF ACM. CONTRACTOR MUST ADHERE TO ALL FEDERAL AND STATE LAW IN REGARDS TO ACM ABATEMENT. REPORT FROM FIELD TESTS PERFORMED IN MARCH 2018 PROVIDED WITH ABATEMENT SPECIFICATIONS.
AutoCAD SHX Text
E UNIT EAST
AutoCAD SHX Text
AutoCAD SHX Text
E-STAFF OFFICES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
E UNIT WEST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text TESTING LOCATIONS: : 1. FIELD NONE DETECTED FIELD NONE DETECTED NONE DETECTED 2. FLASHING NONE DETECTED FLASHING NONE DETECTED NONE DETECTED 3. FLASHING DEEP NONE DETECTED FLASHING DEEP NONE DETECTED NONE DETECTED 4. FIELD NONE DECTED FIELD NONE DECTED NONE DECTED 5. FLASHING (SILVER COAT) 5% CHRYSOTILE FLASHING (SILVER COAT) 5% CHRYSOTILE 5% CHRYSOTILE 6. FLASHING DEEP NONE DETECTED FLASHING DEEP NONE DETECTED NONE DETECTED 7. FIELD NONE DETECTED FIELD NONE DETECTED NONE DETECTED 8. FLASHING NONE DETECTED FLASHING NONE DETECTED NONE DETECTED 9. FLASHING DEEP NONE DETECTED FLASHING DEEP NONE DETECTED NONE DETECTED DETECTED
AutoCAD SHX Text
ASBESTOS CONTAINING MATERIAL ABATEMENT
AutoCAD SHX Text
ACM
3"
PENETRATION
PRE-MOLDED PIPE FLASHING
12" SEAM
12" SEAM
ROOF SLOPE
NOTES:
1. APPLY LAP
SEALANT
AROUND
ENTIRE
PERIMETER
OF
FLASHING.
2. 12" SEAM
OVERLAPS
3" (76 mm)
AT CENTER
OF
PENETRATION.
CONTINUOUS BEAD OF LAP SEALANT
AutoCAD SHX Text
S.HUFFORD
AutoCAD SHX Text 11/1/2018
AutoCAD SHX Text
AutoCAD SHX Text 4C6K
AutoCAD SHX Text
NOTE: 12" MINIMUM D-RING HEIGHT FROM FINISHED LAYER.
AutoCAD SHX Text CONCRETE ANCHOR DETAIL FALL PROTECTION TIE DOWN POINTS FOR WORKING ALONG-SIDE ROOF EDGE. MUST MEET OSHA STANDARDS FOR FALL PROTECTION. EXAMPLE ONLY. SEE STATEMENT OF WORK. 2'X2' BASE. 12" OR GREATER HEIGHT.
AutoCAD SHX Text NOTE: ANCHORS ARE TO BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. ANCHORS INSTALLED TO CONCRETE DECK MUST MEET OSHA REQUIREMENTS FOR FALL PROTECTION.
AutoCAD SHX Text
FALL PROTECTION ANCHORS
AutoCAD SHX Text
ANCHORS
S.HUFFORD
AutoCAD SHX Text 11/1/2018
AutoCAD SHX Text
AutoCAD SHX Text 4C6K
AutoCAD SHX Text NOTE: : FALL PROTECTION ANCHORS ARE TO BE INSTALLED BY THE CONTRACTOR PER MANUFACTURERS SPECIFICATIONS. LOCATIONS SHOWN ARE APPROXIMATE. IT IS THE CONTRACTORS RESPONSIBILITY TO DETERMINE PROPER LOCATIONS FOR INSTALLATION. A TOTAL OF EIGHT (8) ANCHORS WILL BE INSTALLED. SEE STATEMENT OF WORK FOR DETAILED SPECIFICATIONS.
AutoCAD SHX Text
FALL PROTECTION ANCHOR LOCATIONS
AutoCAD SHX Text
FALL PROTECTION ANCHOR
AutoCAD SHX Text
ANCHOR LOCATIONS
EPDM MEMBRANE ROOFING:
INSTALLED TO MANUFACTURERS
SPECIFICATIONS. SEE BASIS OF DESIGN IN
STATEMENT OF WORK. VARIOUS TYPES OF
EPDM MEMBRANE ROOFING ARE AVAILABLE,
TO INCLUDE HOW EACH TYPE IS TO BE
AFFIXED. NEW INSTALLATION MUST BE 90 MIL
EPDM. EPDM ROOF IS CURRENTLY ROCK
BALLASTED. NEW ROOF IS TO BE A
NON-BALLASTED SYSTEM. SYSTEM IS TO BE
INSPECTED BY MANUFACTURER TO ENSURE
INSTALLATION IS COMPLETED TO
MANUFACTURERS SPECIFICATIONS FOR
WARRANTY.
1. REMOVE ALL EXISTING ROOFING,
BALLAST, EPDM, BUILT-UP, ROOF
INSULATION, CURB, WALL, METAL
FLASHING, FASCIA AND EDGE
MATERIAL.
2. LAY NEW INSULATION, TAPERD
INSULATION AND COVERBOARD.
3. INSTALL NEW NAILERS AND BLOCKING
WHERE REQUIRED.
4. INSTALL NEW EPDM MEMBRANE
ROOFING, VAPOR BARRIER, TAPERED
INSULATION, CURB, WALL, FALL
PROTECTION ANCHORS, METAL
FLASHING AND EDGE MATERIAL.
5. REPAIR ANY DAMAGED BRICK AT WALL
TERMINATIONS.
6. CREATE SHOP DRAWING FOR OWNER
RECORDS.
7. INSTALL NEW PAVERS.
8. PROVIDE 20 YEAR SYSTEM WARRANTY.
9. PROVIDE 2 YEAR LABOR AND MATERIAL
WARRANTY FROM LICENSED
INSTALLER.
INSULATION
PRIMER
.090" EPDM MEMBRANE
.090" EPDM MEMBRANE
SUBSTRATE
BONDING ADHESIVE
1/8" (3 mm) TO 1/2" (13 mm)
NOTE:
1. END LAPS OF SEAM SPLICE TAPE MUST OVERLAP A
MINIMUM OF 1" (25 mm).
2. END LAPS OF 5" SEAM FLASHING MUST OVERLAP A MINIMUM
OF 3" (76 mm).5" SEAM FLASHING CENTERED
OVER LAP SPLICE
3" SEAM SPLICE TAPE
AutoCAD SHX Text
S.HUFFORD
AutoCAD SHX Text 11/1/2018
AutoCAD SHX Text
AutoCAD SHX Text 4C6K
AutoCAD SHX Text
EDPM INSTALLATION DETAILS
AutoCAD SHX Text
EDPM
INSULATION
SUBSTRATE
WALL / CURB
.090" EPDM MEMBRANE
SEAM STRIP
PRIMER
SEAM STRIP MUST EXTEND
1/2" (13 mm) BEYOND BATTEN STRIP
BONDING ADHESIVE
USE APPROPRIATE
TERMINATION
BATTEN FASTENED WITH
FASTENERS 12" (305 mm)O.C. MAX.
(SEALANT OVER FASTENER HEADS)
ADHESIVE
WALL
ANCHOR CLIP
COPING
BONDING ADHESIVE
1/2" (13 mm) MIN.
USE APPROPRIATE BASE TIE-IN
1/2" (13 mm) MIN.
11-1/2" MAX
1-3/4" 5d STAINLESS STEEL RING SHANK NAILS AT 24" (610 mm) O.C. MAX.
.090"EPDM MEMBRANE
1-3/4" 5d STAINLESS STEEL RING SHANK NAILS AT 8" (203 mm) O.C. MAX.
WOOD NAILER
COPING COVER FASTENER
12" O.C. (305 mm)(SUPPLIED W/ COPING)
COPING SYSTEM
3" REAR FACE, FIXED
COPING SYSTEM 6" MAX FACE
AutoCAD SHX Text
S.HUFFORD
AutoCAD SHX Text 11/1/2018
AutoCAD SHX Text
AutoCAD SHX Text 4C6K
AutoCAD SHX Text
CURB AND FLASHING DETAIL
AutoCAD SHX Text
CURB
COMPRESSION RING
STRAINER BASKET
1/2" (13 mm) MIN.
BONDING ADHESIVE
INSULATION
INSULATION
SUBSTRATE
12" (305 mm)
6" MAX.
(152 mm)
SUBSTRATE
NOTES:
1. HOLE IN MEMBRANE SHOULD EXTEND A MINIMUM OF
1/2" (13 mm) BEYOND CLAMPING RING AND SHOULD NOT BE SMALLER
THAN THE DIAMETER OF THE LEADER PIPE.
2. INSULATION ADJACENT TO DRAIN TO BE APPROPRIATE FIRESTONE
INSULATION WITH APPROPRIATE BONDING SURFACE.
3. WATERBLOCK MIN. OF 1/2 OF 10 OZ (295 ml) TUBE PER 4" DRAIN. USE
ADDITIONAL WATERBLOCK FOR LARGER DRAINS.
4. IN REROOF APPLICATIONS:
- REMOVE EXISTING FLASHINGS DOWN TO METAL BOWL
- REPAIR OR REPLACE BROKEN DRAIN COMPONENTS
- DRILL AND TAP BROKEN DRAIN BOLTS AND REPLACE IF NECESSARY.
CONTINUOUS BEAD OF FIRESTONE
.090"EPDM MEMBRANE
AutoCAD SHX Text
S.HUFFORD
AutoCAD SHX Text 11/1/2018
AutoCAD SHX Text
AutoCAD SHX Text 4C6K
AutoCAD SHX Text
ROOF DRAIN DETAILS
AutoCAD SHX Text
ROOF DRAIN
5 STEP LADDER-UP
AutoCAD SHX Text
PAVERS
AutoCAD SHX Text
10 STEP LADDER-UP
AutoCAD SHX Text
5 STEP LADDER-UP
AutoCAD SHX Text
PAVERS
AutoCAD SHX Text
PAVERS
AutoCAD SHX Text
S.HUFFORD
AutoCAD SHX Text 11/1/2018
AutoCAD SHX Text
AutoCAD SHX Text 4C6K
AutoCAD SHX Text
ROOF ACCESS
AutoCAD SHX Text
VENT
AutoCAD SHX Text
CURB
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
DRAIN LITER
AutoCAD SHX Text
NOTE: THIS PENETRATION NO LONGER IN USE REMOVE.
AutoCAD SHX Text
DRAIN LITER
AutoCAD SHX Text NOTE: : ALL 3 ROOF SECTIONS ARE CURRENTLY BALLASTED BY ROCK. IT IS THE CONTRACTORS RESPONSIBILITY TO REMOVE AND DISPOSE OF ROCK BALLAST. EPDM ALONG EDGES AND FLASHING HAS PULLED AWAY DUE TO AGE. MUCH OF THE EXISTING INSULATION IS SATURATED. DRAIN LITERS MAY BE IN DISREPAIR AND WILL BE INSPECTED BY THE CONTRACTOR AND THE COR TO IDENTIFY IF REPLACEMENT IS REQUIRED.
AutoCAD SHX Text
CURRENT CONDITIONS
AutoCAD SHX Text
VENT
AutoCAD SHX Text
AutoCAD SHX Text
CURRENT CONDITIONS
APP/1.5" BALLASTED ROCK
| Sheets and Views |
| 4C6K 19 Replace E-Unit Roof with Coversheet UPDATED-COVERSHEET |
| 4C6K 19 Replace E-Unit Roof with Coversheet UPDATED-ROOF MEASUREMENTS |
| 4C6K 19 Replace E-Unit Roof with Coversheet UPDATED-PENETRATIONS |
| 4C6K 19 Replace E-Unit Roof with Coversheet UPDATED-ACM |
| 4C6K 19 Replace E-Unit Roof with Coversheet UPDATED-ANCHORS |
| 4C6K 19 Replace E-Unit Roof with Coversheet UPDATED-ANCHOR LOCATIONS |
| 4C6K 19 Replace E-Unit Roof with Coversheet UPDATED-EDPM |
| 4C6K 19 Replace E-Unit Roof with Coversheet UPDATED-CURB |
| 4C6K 19 Replace E-Unit Roof with Coversheet UPDATED-DRAIN |
| 4C6K 19 Replace E-Unit Roof with Coversheet UPDATED-CURRENT |
| 2018-12-06T11:34:07-0600 | |
| CAROL IDEN |