1572- Addendum 1_UPDATED.pdf

PDF 5 MB Posted

Attached to
CCC & UH ED Weapons Detection and Pressure Monitor Replacement
Solicitation number
2137890
Issued by
Onondaga County, New York

About this file

Summary of Addendum 1 for CCC & UH ED Weapon Detection System and Pressure Monitor Replacement

This document is Addendum 1 to the Contract Documents for SUNY Upstate Medical University's project 151299/1572, issued by the Design and Construction department on August 13, 2026. The addendum modifies the original Project Manual dated July 23, 2026, and includes revisions to administrative and quality requirements sections, fire suppression piping specifications, HVAC system specifications, and electrical systems. The addendum comprises 123 total pages, including two pages of modifications, four revised drawings, and 27 updated specification sections. Key revisions include modifications to Section 013000 (Administrative Requirements) regarding project coordinator responsibilities and section 3.01.C.5 regarding personnel designation, revisions to Section 014000 (Quality Requirements) addressing sprinkler layout coordination with ceiling installation and hydraulic calculations, and formatting updates to 23 additional specification sections covering fire protection hangers and supports, HVAC piping, ductwork, controls, and equipment. The drawing revisions update the sheet list and rename sheets G-107 to "Logistics Plan" and G-108 to "RPM Waste Logistics Plans," with detailed logistics plans provided for emergency department work, waste removal routes, elevator usage, and temporary staging areas. No questions were received regarding the addendum. The Project Team includes Ben Obrist as Project Manager, Mohamed M. Razak as Architecture, Timothy Howe as Plumbing/Mechanical/Fire Protection, and Scott Beeman as Electrical.

The addendum must be acknowledged on the Form of Proposal and becomes part of the Contract Documents as though originally included. Bidders are required to review all 123 pages of addendum materials, including detailed logistics plans showing site constraints, dumpster locations, material delivery restrictions (Monday-Friday before 8 a.m. or after 4 p.m.), elevator routes for waste removal, and construction coordination requirements with hospital operations. The logistics plans identify specific elevator banks for different building areas (University Hospital, Concentrated Care Center, East Tower, and Computer Warehouse), restricted parking areas, ambulance traffic requirements that cannot be interrupted, and restricted parking of contractor vehicles along Elizabeth Blackwell Drive. The addendum specifies strict operational requirements including night-hour work scheduling (7 p.m. to 7 a.m.) for work interrupting emergency department operations, locked staging areas, and coordination with the hospital regarding dumpster pickup and material delivery. All mechanical, electrical, and plumbing work inside the emergency department requires prior approval from the Campus Project Manager and Emergency Department Director regarding times, dates, and work locations.

View the file

Other files

File Type Posted
2. Notice to Bidders_121625.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

151299/1572 CCC & UH ED Weapon Detection System and Pressure Monitor Replacement

ADDENDUM 1

Project: 151299/1572

CCC & UH ED Weapon Detection System and Pressure Monitor Replacement

Addendum 1

Upstate Medical University

Prepared By:

Design and Construction

SUNY Upstate Medical University

750 East Adams Street

Syracuse, NY 13210

(315) 464-3810

Date of Addendum: August 13, 2026

The following addendum adds to, modifies, or deletes from the drawings and specifications issued in accordance with the

Project Manual dated July 23, 2026. This addendum is hereby made a part of the Contract Documents as though it were originally included therein and must be acknowledged on the Form of Proposal.

This Addendum is two (2) pages with four (4) drawings and twenty seven (27) specifications for a total of one hundred and twenty three (123) pages.

PROJECT MANUAL:

1. 013000 - ADMINISTRATIVE REQUIREMENTS – REVISE section 1.04.B to read “Cooperate with the Project

Coordinator in allocation of mobilization areas of site; for field offices and sheds, for access, traffic, and parking facilities.” REVISE section 3.01.C.5 to read “Designation of personnel representing the parties to Contract and

Architect..”

2. 014000 - QUALITY REQUIREMENTS – REVISE section 1.03.2 to read: “Sprinkler Layout: Coordinate with ceiling installation, detailed pipe layout, and hydraulic calculations as described in Section 211313 - Wet-Pipe

Sprinkler Systems.”

3. 210529 - HANGERS AND SUPPORTS FOR FIRE SUPPRESSION PIPING AND EQUIPMENT – REVISED formatting.

4. 210553 - IDENTIFICATION FOR FIRE-SUPPRESSION PIPING AND EQUIPMENTMEN – REVISE Part 1 -

GENERAL section and formatting.

5. 211313 - WET-PIPE SPRINKLER SYSTEMS – REVISE section 2.1.A.1.c reference to “U of R” and formatting

6. 230517 - SLEEVES AND SLEEVE SEALS FOR HVAC PIPING – REVISE Part 1 - GENERAL section and formatting.

7. 230518 - ESCUTCHEONS FOR HVAC PIPING – REVISE Part 1 - GENERAL section and formatting.

8. 230519 - METERS AND GAGES FOR HVAC PIPING – REVISED formatting.

9. 230523.12 - BALL VALVES FOR HVAC PIPING – REVISED formatting.

10. 230529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT – REVISED formatting.

11. 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT – REVISED formatting.

12. 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC – REVISED formatting.

13. 230713 - DUCT INSULATION – REVISED formatting.

14. 230719 - HVAC PIPING INSULATION – REVISED formatting.

15. 230800 - COMMISSIONING OF HVAC – REVISED formatting.

16. 230923 - DIRECT DIGITAL CONTROL (DDC) SYSTEM FOR HVAC – REVISED formatting.

17. 230923.11 - CONTROL VALVES – REVISED formatting.

18. 232113 - HYDRONIC PIPING – REVISED formatting.

151299/1572 CCC & UH ED Weapon Detection System and Pressure Monitor Replacement

19. 232116 - HYDRONIC PIPING SPECIALTIES – REVISED formatting.

20. 233113 - METAL DUCTS – REVISED formatting.

21. 233300 - AIR DUCT ACCESSORIES – REVISED formatting.

22. 233346 - FLEXIBLE DUCTS – REVISED formatting.

23. 233433.13 - COMMERCIAL AIR CURTAINS – REVISED formatting.

24. 233713.13 - AIR DIFFUSERS – REVISED formatting.

25. 233713.23 - REGISTERS AND GRILLES – REVISED formatting.

26. 238113.11 - PACKAGED TERMINAL AIR-CONDITIONERS, THROUGH-WALL UNITS – REVISED

formatting.

27. 238216.11 - HYDRONIC AIR COILS – REVISED formatting.

DRAWINGS:

1. REVISED sheet list on cover sheet to change the naming of sheets G-108, E-112 and E-113.

2. REVISED title of sheet G-107 to “LOGISTICS PLAN”.

3. REVISED title of sheet G-108 to “RPM WASTE LOGISTICS PLANS”.

4. REVISED drawing E-000 to show the correct sheet list.

QUESTIONS RECEIVED: None.

ATTACHMENTS: Drawing and specifications

End of Addendum

Stantec Project Number:

Client Project Number: 151299 / 1572

The professional's seal on the cover sheet represents that the information on the cover sheet is accurate in designer's professional opinion but does not assume professional responsibility for documents sealed by others that are referenced on the cover sheet.

All professionals sealing drawings as a part of the design are professionally responsible for their own sealed documents.

750 E Adams St, Syracuse, NY 13210

ADDENDUM 1

2026.08.07

CCC & UH ED

WEAPON

DETECTION SYSTEM AND

PRESSURE MONITOR

REPLACEMENT

191506670

PROJECT TEAM

UPSTATE PROJECT MANAGER

BEN OBRIST

SUNY UPSTATE MEDICAL UNIVERSITY

650 S. SALINA STREET

SYRACUSE, NY 13202

OFFICE: (315) 464-1788

CELL: (315) 956-1754

OBRISTB@UPSTATE.EDU

ARCHITECTURE

MOHAMED M. RAZAK AIA LEED AP BD+C

RAZAK ASSOCIATES

255 EAST AVE #306

ROCHESTER, NY 14604

P: (585) 506-2126

F: (585) 388-6712

MRAZAK@RAZAK.NET

PLUMBING

TIMOTHY HOWE, PE

STANTEC CONSULTING SERVICES INC.

61 COMMERCIAL STREET SUITE 100

ROCHESTER NY 14614-1009

OFFICE: 585-281-3223

TIMOTHY.HOWE@STANTEC.COM

STANTEC PROJECT MANAGER

TIMOTHY HOWE, PE, CCP, LEED AP

STANTEC CONSULTING SERVICES INC.

61 COMMERCIAL STREET SUITE 100

ROCHESTER NY 14614-1009

CELL: (585) 281-3223

TIMOTHY.HOWE@STANTEC.COM

MECHANICAL

TIMOTHY HOWE, PE

STANTEC CONSULTING SERVICES INC.

61 COMMERCIAL STREET SUITE 100

ROCHESTER NY 14614-1009

OFFICE: 585-281-3223

TIMOTHY.HOWE@STANTEC.COM

FIRE PROTECTION

TIMOTHY HOWE, PE

STANTEC CONSULTING SERVICES INC.

61 COMMERCIAL STREET SUITE 100

ROCHESTER NY 14614-1009

OFFICE: 585-281-3223

TIMOTHY.HOWE@STANTEC.COM

ELECTRICAL

SCOTT BEEMAN

WATSON ENGINEERING, PC

4500 STATE ROUTE 434

APALACHIN, NY 13732

OFFICE: 607-223-4334

CELL: 607-738-9955

SCOTT@WATSON-ENGINEER.COM

TRUE

NORTH

AREA MAP LOCATION MAP

E ADAMS ST

IN

T

E R

S T

A T

E I

-8

A

LM

O N

D S

T

S A

R A

H L

O U

G E

N S

T

E

LI

Z A

B E

T H

B

LA

C K

W E

LL

S

T

MONROE ST

IR

V

IN

G

A V

E

FA-201 FIRE ALARM NEW WORK ENLARGED RCP - CCC 2ND FLOOR

FAD-201 FIRE ALARM DEMOLITION ENLARGED RCP - CCC 2ND FLOOR

FIRE ALARM

E-502 ELECTRICAL SCHEDULES

E-501 ELECTRICAL DETAILS

E-202 ELECTRICAL NEW WORK ENLARGED RCP – CCC 2ND FLOOR

E-201 ELECTRICAL NEW WORK ENLARGED PLAN – CCC 2ND FLOOR

E-113 ELECTRICAL POWER PLAN – UH 8TH FLOOR

E-112 ELECTRICAL POWER PLAN – UH 7TH FLOOR

E-111 ELECTRICAL POWER PLAN – UH 6TH FLOOR

E-110 ELECTRICAL POWER PLAN – UH 4TH FLOOR

P-100 PLUMBING DEMOLITION PLAN - CCC 2ND FLOOR E-109 ELECTRICAL POWER PLAN – VE 12TH FLOOR

P-000 PLUMBING LEAD SHEET E-108 ELECTRICAL POWER PLAN – VE 11TH FLOOR

E-107 ELECTRICAL POWER PLAN – VE 10TH FLOORPLUMBING

E-106 ELECTRICAL POWER PLAN – VE 9TH FLOOR

FP-500 FIRE PROTECTION DETAILS AND SCHEDULES E-105 ELECTRICAL POWER PLAN – VE 8TH FLOOR

FP-100 FIRE PROTECTION PLAN - CCC 2ND FLOOR E-104 ELECTRICAL POWER PLAN – CCC 6TH FLOOR

FPD-100 FIRE PROTECTION DEMOLITION PLAN - CCC 2ND FLOOR E-103 ELECTRICAL POWER PLAN – CCC 5TH FLOOR

FP-000 FIRE PROTECTION LEAD SHEET E-102 ELECTRICAL POWER PLAN – CCC 3RD FLOOR

E-101 ELECTRICAL POWER PLAN – CCC 2ND FLOORFIRE PROTECTION

ED-202 ELECTRICAL DEMOLITION ENLARGED RCP – CCC 2ND FLOOR

A-940 WINDOW TYPES AND DETAILS ED-201 ELECTRICAL DEMOLITION ENLARGED PLAN – CCC 2ND FLOOR

A-931 FINISH SCHEDULE ED-101 ELECTRICAL DEMOLITION PLAN – CCC 2ND FLOOR

A-930 DOOR SCHEDULE AND DETAILS E-001 ELECTRICAL LEAD SHEET (2 OF 2)

A-923 WINDOW REPLACEMENT E-000 ELECTRICAL LEAD SHEET (1 OF 2)

A-922 TEMPORARY VESTIBULE 2

A-921 TEMPORARY VESTIBULE

ELECTRICAL

A-920 STAFF CHARTING AND RADIO ROOM ELEVATIONS M-703 MECHANICAL CONTROLS

A-901 AUTOMATIC SLIDING ENTRANCE DETAILS M-702 MECHANICAL CONTROLS

A-900 CONSTRUCTION DETAILS M-701 MECHANICAL CONTROLS

A-800 INTERIOR ELEVATIONS M-700 MECHANICAL CONTROLS

A-700 FINISH FLOOR AND WALL PLAN M-600 MECHANICAL SCHEDULES

A-600 PARTITION TYPES M-501 MECHANICAL DETAILS

A-200 REFLECTED CEILING PLAN AND DETAILS M-500 MECHANICAL DETAILS

A-101 PROPOSED FFE PLANS M-115 MECHANICAL FLOOR PLANS - UH 8TH FLOOR

A-100 PROPOSED CONSTRUCTION PLAN M-114 MECHANICAL FLOOR PLAN - UH 7TH FLOOR

AD-101 DEMOLITION PLANS REFLECTED CEILING PLAN M-113 MECHANICAL FLOOR PLAN - UH 6TH FLOOR

AD-100 DEMOLITION PLAN M-112 MECHANICAL FLOOR PLAN - UH 5TH FLOOR

A-004 ICRA PLAN 3 M-111 MECHANICAL FLOOR PLAN - UH 4TH FLOOR

A-003 ICRA PLAN 2 M-110 MECHANICAL FLOOR PLAN - VE 12TH FLOOR

A-002 ICRA PLAN 1 M-109 MECHANICAL FLOOR PLAN - VE 11TH FLOOR

A-001 EXISTING CONDITIONS REFLECTED CEILING PLAN M-108 MECHANICAL FLOOR PLAN - VE 10TH FLOOR

A-000 EXISTING CONDITIONS M-107 MECHANICAL FLOOR PLAN - VE 9TH FLOOR

M-106 MECHANICAL FLOOR PLAN - VE 8TH FLOORARCHITECTURE

M-105 MECHANICAL FLOOR PLAN - CCC 6TH FLOOR

G-108 RPM WASTE LOGISTICS PLANS M-104 MECHANICAL FLOOR PLAN - CCC 5TH FLOOR

G-107 LOGISTICS PLAN M-103 MECHANICAL FLOOR PLAN - CCC 3RD FLOOR

G-106 PHASING PLANS 2 M-102 MECHANICAL FLOOR PLAN - CCC 2ND FLOOR

G-105 PHASING PLANS 1 M-101 MECHANICAL PIPING PARTIAL PLAN - CCC 2ND FLOOR

G-104 LIFE SAFETY PLANS M-100 MECHANICAL HVAC PARTIAL PLAN - CCC 2ND FLOOR

G-103 GENERAL NOTES MD-101 MECHANICAL PIPING DEMOLITION PLAN - CCC 2ND FLOOR

G-102 CODE ANALYSIS MD-100 MECHANICAL HVAC DEMOLITION PLAN - CCC 2ND FLOOR

G-101 SYMBOLS & ABBREVIATIONS M-000 MECHANICAL LEAD SHEET

GENERAL MECHANICAL

SHEET NUMBER SHEET NAME SHEET NUMBER SHEET NAME

SHEET LIST

E

F

D

1 2 3

G

AREA OF

WORK

6' LOCKABLE

GATE IN

FENCING

40 YARD

DUMPSTER

22' -0" X 8'-0" X 8'-0"

DESIGNATE A

TEMPORARY SPOT

NEXT TO STAGING

AREA FOR THE

DURATION OF

CONSTRUCTION FOR

THE CONTRACTOR.

M A

IN

T

A

IN

A M

B U

LA

N

C E

P A

R K

IN

G

A R

E A

D U

R

IN

G T

H E

D U

R A

T

IO

N O

F

C

N S

T R

U C

T

IO

N

SIDEWALK

AREA OF

WORK IN

WAITING

ROOM

EXISTING

BOLLARDS

TO REMAIN

U.O.N.

EMERGENCY DEPARTMENT

ENTRANCE MUST BE FREE

OF ANY OBSTRUCTIONS

FOR THE DURATION OF THE

PROJECT

DECONTAM

SHOWER

E2617

WC

STOR

E2616 STORAGE

E2610

TRAUMA

E2608

VESTIBULE

E2615

CORRIDOR

E2604A

EMS

ENTRY

E2618

WALK-IN

ENTRY

E2620

EXAM

ROOM

E2619

RADIO

ROOM

E2665

ISOLATION

E2663

EXAM

E2661

RECEPTION

E2625

WAITING

ROOM

E2624

SECURITY

OFFICE

E2662

PROVIDE FENCED IN

STAGING AREA

SUPPORTED BY

SAND BAGS FOR

GENERAL STORAGE

AND DUMPSTER

LOCATION

STAGING

AREA

OS 3

6'

-6

7'-9"

'-0

E X

IS

T

IN

G

P U

B

LI

C S

ID

E

W A

LK

E A

S T

A D

A M

S T

R E

E T

(O N

E W

A Y

T R

A F

F

IC

EXISTING PARKING LOT

AMBULANCE TRAFFIC INTO

AND OUT OF EMERGENCY

DEPARTMENT PARKING SHALL

NOT BE REDUCED OR

RESTRICTED FOR THE

DURATION OF CONSTRUCTION

6'

- 1

1/

18'-4"

EXISTING BOLLARD TO

BE REMOVED FOR

TEMPORARY PARTITION

AND CONSTUCTION

VESTBULE ENTRANCE

CONTRACTOR

PROVIDED

DUMPSTER

LOGISTICS NOTES

1. CONTRACTOR TO PROVIDE AN OPERATIONS PLAN, SAFETY PLAN AND

SCHEDULES FOR ALL REQUIRED STEPS IN CONSTRUCTION. THIS PLAN WILL

INCLUDE INFORMATION RELATED TO FENCING, WORK AREA, STORAGE STAGING

AREA

2. OPERATIONS AND SAFETY PLAN SHALL BE COORDINATED WITH THE HOSPITAL

AND TO BE APPROVED PRIOR TO ANY WORK TAKING PLACE.

3. INTERIOR MECHANICAL, ELECTRICAL, PLUMBING WORK INSIDE THE EMERGENCY

DEPARTMENT IS TO BE CLOSELY COORDINATED WITH CAMPUS PROJECT

MANAGER AND EMERGENCY DEPARTMENT DIRECTOR. THE TIMES, DATES AND

LOCATION OF WORK SHALL BE SUBMITTED TO THE CAMPUS FOR PRIOR

APPROVAL.

4. ANY MECHANICAL, ELECTRICAL, PLUMBING WORK INSIDE THE EMERGENCY

DEPARTMENT THAT INTERRUPTS OPERATIONS WILL BE PERFORMED DURING NIGHT

HOURS BETWEEN 7PM - 7AM. CONTRACTOR TO COORDINATE WITH OWNER.

5. CONSTRUCTION FENCING TO BE PORTABLE BALLASTED CHAINLINK FENCE

PANELS, 6'-0" HIGH WITH CONSTRUCTION SCREEN FABRIC.

6. STAGING FENCE TO BE LOCKED WHEN NOT IN USE

7. THERE WILL BE NO PARKING OR STAGING OF WORK VEHICLES, DELIVERY

VEHICLES OR EQUIPMENT ALONG ELIZABETH BLACKWELL DRIVE AT ANY TIME.

8. TWO WAY AMBULANCE TRAFFIC INTO AND OUT OF EMERGENCY DEPARTMENT

PARKING LOT SHALL NOT BE REDUCED OR RESTRICTED FOR THE DURATION OF

THE PROJECT.

9. MATERIAL DELIVERIES ARE TO OCCUR ONLY MONDAY - FRIDAY BEFORE 8 AM

AND AFTER 4PM. CONTRACTOR TO COORDINATE WITH OWNER.

10. DELIVERIES NEED TO BE TAKEN DIRECTLY TO AREA OF WORK U.O.N.

DELIVERIES TO BE REDIRECTED TO EAST WATER STREET AND S CROUSE

AVE IF DROP OFF AT AREA OF WORK IS NOT POSSIBLE.

11. AREA DESIGNATED FOR STAGING MAY GROW AT THE SOLE DISCRETION OF THE

OWNER.

12. DUMPSTER WILL BE PROVIDED BY THE CONTRACTOR.

13. DUMPSTER SHALL NOT BLOCK UTILITY MANHOLES OR UNDERGROUND ACCESS

POINTS. DUMPSTER PICK UP TIME TO BE COORDINATED WITH THE HOSPITAL. OFF

HOUR PICKUPS MAY BE REQUIRED

14. CONTRACTOR WILL BE ALLOTTED 1 PARKING SPACE IN THE EMERGENCY

DEPARTMENT PARKING LOT, AND 4 PARKING SPACES FOR DUMPSTER AREA.

LEGEND

FENCE

AREA NOT IN CONTRACT SCOPE

AREA OF FOCUS

ALL LARGE LAYDOWN

STORAGE AND EQUIPMENT

TO BE STORED HERE:

-EAST WATER STREET AND

S CROUSE AVE

-EAST WATER STREET AND

IRVING AVE.

NOTE:

PROVIDE FENCED IN

STAGING AREA AROUND

THE DESIGNATED

LOCATION, COORDINATED

WITH THE OWNER.

AREA OF

WORK

E W

A T

E R

S T

UNIVERSITY AVE

S CROUSE AVE

IRVING AVE

FORMAN AVE

ALMOND ST

E W

A S

H

IN

G T

O N

S T

E F

A Y

E T

T E

S T

E G

E N

E S

E E

S T

M A

D

IS

O N

S T

H A

R R

IS

O

N S

T

E A

D A

M S

T

ELIZABETH

BLACKWELL ST

M O

N R

O E

S T

ED 2ND FLOOR

TRUE

NORTH

Th e

C o p yr ig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c

R e p ro d u c tio n o r u se f o r a n y p u rp o se o th e r th a n t h a t a u th o ri ze d b y S ta n te c is f o rb id d e n

Th e

C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.

D

O N

O T sc a le t h e d ra w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o

S ta n te c w ith o u t d e la y

C o p yr ig h t R e se rv e d

ORIGINAL SHEET - ARCH D

Is su e d

/R e v is io n

B y

A p p d

Y Y

Y Y

.M M

.D D

A

2 3 4 5

B

C

D

C o n su lt a n ts

Permit/Seal

Revision:

Project No.:

Title

Scale:

Drawing No.

A R C H

IT

E C

TU

R E

R A

ZA

K

A

SS

O C

IA

TE

S

E

A

ST

A V

E

R O

C H

ES

TE

R N

Y

E L E C

TR

IC

A L

W A

TS

N

EN

G

IN

EE

R

IN

G P

C

S

TA

TE

R

O U

TE

A P

A

LA

C H

IN

N Y

Key Plan

Is su e d f o r B id R

A

ZA

K

.0 7.

A

D D

E N

D U

M

R A

ZA

K

.0

8.

/1

/2

:3

:2

A

M

As indicated

151299 / 1572 CCC &

UH ED Weapon Detection System and Pressure Monitor Replacement

UPSTATE MEDICAL

UNIVERSITY

750 E Adams St, Syracuse, NY 13210

191506670

G-107

LOGISTICS PLAN

1/8" = 1'-0"

EMERGENCY DEPARTMENT LOGISTIC PLAN

1" = 1'-0"

STORAGE LOCATION

D a te

C L OCKER C L OCKER C L OCKER

BL ANKET

W ARM ER

(3 0 "W x 26 .5"D 7 4 .5"H)

OM NICEL L

PYXIS W /

M ONITOR

PYXIS W /

FRIDGE ON

TOP

OM NICEL L

ATMATM

SECUR RM

JANITOR

ELEC.

SOIL LINEN

PRISONEER HLDING

AUX. STORAGE

TELE.

STOR. SACRISTRY STG

TELECOMOFFICE

SPRTUAL CARE OFC

OFFICE

CLIN DATA RVW RM

STAIR #2

JAN.

RN ADMIN ASSTNT

VENDINGCOPY

OPEN OFFICE

STOR.

NEUROLOGY OFC

NEUROLOGY OFC

CHAPLIN INTERNS

SPIRTUAL CARE

CNL OFFICECNL OFFICE

SOUND RM

STAIR #3

ENVIR SERV

STORAGE

CORRIDOR

CHAPEL

WOMEN

TOILET

MEN

TOILET

CARE

SPIRITUAL

ATM ROOM

LOBBYELEVATOR LOBBY

HOSPITAL LOBBY

CHASE

CORRIDOR

REG SUPT

CLIN. DATA

ELEV. #2

ELEV. #1

ELEV. #3 ELEV. #4 ELEV. #5 ELEV. #6 ELEV. #7 ELEV. #8

CORRIDOR

CARE

SPIRITUAL

CARE

SPIRITUAL

OFFICE SPRTUAL

OFFICE

FIRE CONTROL PANELS

RN SUPERVSR OFC

NURSNG CLASS RM

OFFICE

OFFICE

CORRIDOR

ELEC. CLST

LINEN CHUTE

FAC OFC

PSYCH FAC OFC

HALLWAY

JANITOR

TOILET

RN FLOAT OFC

ELEC.

OFC

SOCIAL WRK DIR

TOILET

OFFICE

CORRIDOR

RECEPTION

OPHTMAL

MANAGER'S OFFICE

STAIR #4

AP1 FLUM RM

TOILET

CHASE CHASEELEV. #9 ELEV. #10 ELEV. #11

ELEVATOR LOBBY

WOMEN

TOILET

MEN'S

VEST

VESTIBULE

CORRIDOR

CORRIDOR

CORRIDOR

AP1 COAT RM

ELEV. #

STAIR #

OPEN STAIR

G

IF

T S

H O

P S

T O

R

GIFT SHOP

ELEV. MECH

SECURITY/

AMBASSADORS

GREET RM

EXAM RM

RN SUPPORT

REG OFC

OUTPTNT

OUTPTNT

PSYCH

FAC OFC

PSYCH

C O

R R

ID

O

R

TELECOM

MRI WAITING

ADA TOILET

CHANGE

MRI RECEPTION

CAFE

STORAGE

PHARMACY

PHARMACY

WAITING

CONSULTATION

CORRIDOR

ELEC

ENTRANCE TO CANCER

CENTER

VESTIBULE

BADGE INFO

PARKING OFFICE

PARKING

MANAGER

SOIL LINEN

PRISONEER HLDING

STOR.

STORAGE

MECH.

CLIN DATA RVW RM

ADVANCE PARACTICEOFFICE

OFFICE

QUALITY

TRANS CARE

NURSNG ADMIN OFC

ADMIN FILE AREA

RN ADMIN ASSTNT

COPY

HOSPITAL ADMIN

OFFICE

NURSNG ADMIN OFC

HOSPITAL ADMIN

RN ADMIN SUPPORT

NURSNG ADMIN OFC

RN ADMIN SUPPORT

NURSNG ADMIN OFC

NURSNG ADMIN OFC

ELEC.

VESTIBULE

UH CNO OFFICE INCIDNT CMD CNT

UH COO OFFICE

UH ADMIN SUPPRT

UH ADMIN CONF RM

UH CEO OFFICE

UH CAO OFFICE

NURSING PRACTICE

STOR.

SOCIAL WORK

WOMEN

MEN

HOSP ADM

CLOSET

HOSP ADM SUPPORT

NURSING PRACTICE

CLIN DATA OFCCLIN DATA OFC

EMG RECEPTION

UH CFO OFFICE

UH ADMINSTOR OFC

WAITING

CLEAN STORAGE

HOLDING

EMG EXAM RM # 1

EMG FACULITY OFC

EMG EXAM RM # 2EMG EXAM RM # 3

EMG EXAM RM # 4

PT TOILET

EMG EXAM RM # 5

STAIR #1

PULMO FUNCT WAIT

PULMO FUNCT SOIL

PULMO

EMG WORK RM

EEG READ RM

EEG READ RMPULMO FNCT EXAM

BATH

PULMO FUNCT TEST

PULMO FNCT STG

PULMO FUNCT OFC

SPIRITUAL CARE

CHASE

CORRIDOR

STORAGE

ENVIR SERV

STORAGE

CORRIDOR

WOMEN

TOILET

MEN

TOILET

ENTRY

STORAGE

E M

G V

E

ST

IB

U

L E

EMG

CORRIDOR

CORRIDOR

CORRIDOR

ELEV. #2

ELEV. #1

OPN WORK AREA

CHUTE

LINEN

TOILET

TOILET

LINEN CHUTE

PSYCH FAC OFC

PSYCH FAC OFC

PSYCH SECY AREA

RAD OFC

RAD OFC

RAD OFC

RAD OFC

RAD FILE ROOM RAD OFC

RAD OFCRAD OFC

RAD OFC

/OSTOM

CONSTR OFC

GERIATRICS OFC

HALLWAY

OFC

VOL COFFEE CART

SOC SERV OFC

FLDRN OFC

HANDY MAN OFC

PLANT CARP SHOP

PLANT CARP SHOP

PLANT ELECT SHOP

ELECT OFC

PAINT SINK

STAIR #7

ELEVATOR LOBBY

RN SUPRT SRV OFC

SRV OFC

OFFICE

ELEC.

MECHANICAL RM.

PLANT CARP OFC

HALLWAY

MAIL RM.

PLANT ADMIN OFC

PLANT ADMIN OFC

PLANT ADMIN OFC

PLANT MOC OFC

PLANT DIR OFC

PLANT ADMIN OFC

PLANT SECY OFC

STG RM

PLANT PLAN OFC

PLUMBERS CLOSET

PLANT PAINT STG

ELECTRICAL STOR.

W TOILET

PLANT KEY SHOP

ED COMM STORAGE

STAIR #5

CORRIDOR

SOC SVCS OFC

PLANT CARP STG

PLANT ELECT SHOP

ELEV. #12

ELEV. #13

ELEV. #14

CORRIDOR

PLANT ADMIN OFC

M TOILET

CLOSET

CORRIDOR

CHASE

STAIR #6

RAD COPY RM

CORRIDOR

AP-1 PATIENT RM

AP-1 PATIENT RM AP-1 PATIENT RM

A P

-1 R

N S

T A

T

IO

N

AP-1 PATIENT RM

AP-1 PATIENT RM

AP-1 PANTRY

AP-1 DIRTY UTILY

AP-1 PATIENT RM

AP-1 PATIENT RM

AP-1 PATIENT RM

AP-1 PATIENT RM

TOILET

TOILET

TOILET

C O

R R

ID

O

R

VESTIBULE

HALLWAY

CLIN. DATA

CORRIDOR

N U

R S

E S

S T

A T

IO

N

CLEAN SUPPLY RM

AP-1 STAFF LOUNG

PANTRY

RECOVERY

TOILET

CLOSET

ELECTRICAL

KITCHENETTE

RECEPTION

WAITING

CONS

UNIV

LINEN SOIL

NURSING PRACTICE

OFFICE

QUAILTY

SERVICES

VOLUNTR

PAIN/WOUND

PLANT

RN SUPRT

SRV OFC

RN SUPRT SRV OFC

RN SUPRT

SRV OFC

RN SUPRT

PLANT

OFFICE

RAD/SOC SERV

RAD OFC

ELECTRONICS OFFICE

ELECTRONICS SHOP

PLUMBING OFFICE

PLUMBING LOUNGE

PLUMBING

WORKSHOP

PLANT PAINT SHOP

PLANT PAINT

LOUNGE

STORAGE

ADA TOILET

ADA CHANGE

CHANGE

GOWNED WAITING

VESTIBULE

MRI WAITING

MRI RECEPTION

WAITING ROOM

CORRIDOR

ENTRANCE TO CANCER

CENTER

ENTRANCE TOWARDS

GAMMA KNIFE

PHARMACY

CORRIDOR

INFO DESK

MAIN WAITING

RECORDS

DISPATCH CENTER

VOLUNTEER SERVICES

WORKROOMPATIENT

RELATIONS AREA

O P

E N

A R

E A

W A

Y

COUNSELOR #2COUNSELOR #1CONF./BREAK

EDQA

SUP

ED REG

MAN

INSUR

SUP

ADMITING

REGISTRATION

OFFICE

REGISTRATION

STORAGE

ADMIN

ASSISTANT

DIRECTOR PAT.

RELATIONS

CHIEF EXPERIENCE

OFFICER

TOILET

BREAK

VESTIBULE

ENTRANCE INTO

GAMMA KNIFE

HANDY-MAN

OFFICE

HANDY-MAN

WORKSHOP

VESTIBULE

DUMB WAITER

OFFICE

STAFF

TOILET

MECHANICAL

CHANGING POS

EXAM 1

POS

EXAM 2

EXAM 3

EXAM 4

EXAM 5

EXAM 6

EXAM 7

EXAM 8

FAMILY

CONSULT

PRIVATE

OFFICE

PRIVATE

OFFICE

STORAGE

STAFF

BREAK

POS

TOILET

SOILED

WORKROOM

CLEAN

WORK/MED

PREP

ROOM

PATIENT

TOILETHSK

REGISTRATION

WAITING

ROOM

EQUIPMENT/

LINEN

CHART

EQUIPMENT/

LINEN

CHART

EQUIPMENT/

LINEN

CHART

EQUIPMENT

EQUIPMENT

HYPERBARIC

CHANGING

SUB-WAITING

NURSE

STATION

HOLDING

CORRIDOR

TELECOM

OFFICE

REGISTRATION

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CONFERENCE ROOM

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

CORRIDOR

CLINICAL COLLABORATION

CENTER / LOUNGE

NEUROLOGYHOSPITAL ADMIN.

OFFICE

CENTER

FAMILY SERVICE

MANAGER

ADMITTING

CORRIDOR

WAITING AREA

PICK UP /

STORAGE

WORK

STAND UP

COUNSELOR

OFFICE

STORAGE

COUNSELOR #3

SERVICES

VOLUNTEER

MAN.

SERVICES

VOLUNTEER

DIRECTOR

BREAK ROOM

CAFE

OFFICE

OPEN OFFICE

NURSING PRACTICE

OPEN OFFICE

HOSPITAL ADMIN.

OFFICE

HOSPITAL ADMIN.

OFFICE

HOSPITAL ADMIN.

OFFICE

HOSPITAL ADMIN.

OFFICE OFFICE

NURSING ADMIN.

OFFICE

OFFICE

QUAILTY

OFFICE

OFFICE

NURSING PRACTICE

PATIENT FINANCIAL

OFFICE

HOSPITAL ADMIN

OFFICE

MECH.

PASSAGE

1218A

1219A 1219B

1120X

1216B

1216A

1216C

12301229

1313 1315

1229X

1229F

1229Y

1220B

1321G

1321H

1118A

1293Z 1294Z 1295Z 1296Z 1297Z 1298Z

1224A

1319A

1224B 1224C 1224D

1321J

1326A

1328B

1701A

1702A

1702D

1403C

1407C

14211420

1516Y 1515Y1509Z 1510Z 1511Z

1516X

1516A

1522A

1522B

1319Z

1350X

1319X

A

1407A

1407D

1543A

1314B

1600A

1103B 1103C

1102X

11071103A

1105A

1102Y

1111A 1113A 1114A

111OA

1110C

1110F

1110D

1218A

1219A

1300 1302

1307A

1307B 1307C

1307D

1307E

1307F 1307G

1310A

1310B

1310C

1310M

1310D

1310E

1310F1310G

1310H 1310I

1310L

1312A

1312B

1312D 1312E

1312F1312G

1312H

1312I

1312J

1312K

1312L

1313A

1328A

1118B 1118C

1292Z

1291Z

1310J

1203A

1230A

1700X

1702B

1702C

1703A

1703B

1703C

1703D 1703E

1703F

1704A

1704B 1704C

1704D

1706A

1707A

1707B

1707C

1707G 1707D

1707E

1707F

1710A

1710B

1711B

1711A 1713X

1712Z

1713Z

1714Z

1804A

1804B

18071806D

1806C 1806B

1810A

1814B

1814C

1816B

1816A

1816C

1816D

1816E

1713A

1714Y

1706X

1703G

14211420

1637A 1637B

1637F

H

1642A

1637G

1637C

1100D

1100C

1100B

1100A

1100F

1100E

1820A

1814A

1818A

1818B

1547A

Y

1403B1403A1507

1321C

1321D

1321E

1320A

1320B

1321A

1511B

1511B

1321K

1321F

1319B

1801C

1218Z

1714V

1424B

1449A

1449B

1424C1555A

1441B

1441A

1435B

1435A

1429B

1429A

1556A

1424A

1556B

1449D

1543A

1449C

1312C

12151206

1212C

1321B

1314C

1314A

1500A

1402D

1403D

1402A

1402B

1402C

1314D

1130V1120A

ADD WALL

1108A

1/ 16"

ELECTRICAL RM.

CHNG.

CHNG.

CHNG.

ELEC.

CONTROL ROOM CONTROL ROOM

CATSCANCATSCAN

TOILET CHNG.

TOILET

LAUNDRY

BATH

LOUNGE

S T A

IR

A

READING ROOM

DARK ROOM

OFFICE

JAN.

OFFICE

STORAGE

OFFICE

OFFICE

IV PROCEDURE

NURSES STATION

OFFICE

WAITING ROOM

ELEVATOR LOBBY

ELEVATOR LOBBY

CORRIDOR

HALLWAY

TOILET

TOILET

CORRIDOR

CORRIDOR

STRETCHER

CORRIDOR

LN CHUTE

PANTRY

T E

L E

C O

M

TOILET

MEN'S LOCKER

MONITOR RM

JANITOR

CORRIDOR

ELEVATOR

LOBBY

ELEVATOR

#E1

ELEVATOR

#E2

ELEVATOR

#E4

ELEVATOR

#E3

ELEVATOR

#E5

ELEVATOR

#E6

ELEVATOR

#E7

ELECTRICAL

TELECOM

TELECOM

CYLINDER

STORAGESCOPE STORAGE

DIRTY SCOPE

HOLDING

ENDO ROOM

RECOVERY

RECEPTION

INTAKE

HANDICAP

TOILET

STORAGEENDO ROOM

INTERVANT

RADIOLOGY ROOM

OFFICE

DICTATION

CORRIDOR

SCOPE

STORAGE

ENDO ROOM

CORRIDOR

CORRIDORVESTIBULE

JANITOR

VESTIBULE

DICTATION

NURSES STATION

CORRIDOR

TRASH CART

ALCOVE

SOIL

STAGING

SUPERVISING

PHARMACIST

CHEMO

PREPARATION

IV COMPOUNDING

LEVEL 3

IV COMPOUNDING

LEVEL 1

CONFERENCE

ROOM

1 '- 7 3 /4"

1 0'-3"

STAIR #3

PACU #6

PACU #7PACU #8PACU #9PACU 10PACU 11PACU 12PACU GPACU F

CONFERENCE TOILET PACU 16TOILET

SOIL RM

CLN RM

LOCKERS

JAN CLST

ALCOVE

PACU # F

MED RM

CHLD SUR LOUNGE

CHLD SUR LOUNGE

PACU #5

TOILET

PACU # 4 PACU # 3 PACU # 2

STAIR #2

PACU # 1

TOILET

STATION

OFCOFFICE

OFFICE

COFC

CHD SUR WAITING

CNSLT

TELECOM CLST

PRE OP

ELEC RM

JAN CLST

RAD OFFICE

LINEN CHUTE

TRASH RM

CHASE

ELEV. #3 ELEV. #4 ELEV. #5 ELEV. #6 ELEV. #7 ELEV. #8

VESTIBULE

RN STN

LOBBY

FAX/COPY

PACU STG

RN STN

CLN RM

NOURISHMENT

TOILET

WOMEN

TOILET

MEN

CHASE

ELEV. #1

ELEV. #2

CORRIDORCORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CHASE

EQPM ALCOVE

PACU # C PACU # B PACU # A

CHASE

RAD ANGIO NEURO

PYXIS

CHLD SURCHLD SURCHLD SURCHLD SURCHLD SURCHLD SURCHLD SURCHLD SUR

CHLD SUR

CCS

CHLD SUR

CHD SUR CHD SUR CHD SUR CHD SUR

CHD SUR CHD SUR CHD SUR

CHLD SUR CHLD SUR

CHLD SUR

CHLD SUR

CHLD SUR

CHD SUR

CHLD SUR CHD SUR

CHD SUR

CHLD SUR

CHLD SUR

CHLD SUR

HOSP ADMINCHD SUR

IMT SUPPORT

CHLD SUR

CHLD SUR

CHLD

CHLD

PATHOLOGY OFFICECLINICAL

PATHOLOGY

SECRETARY

CLINICAL

PATHOLOGY

CONFERENCE

ROOM

LOCKER

CLINICAL

PATHOLOGY

MECH

3293Z 3294Z 3295Z 3296Z 3297Z 3298Z

N3142 N3143 N3144

N3145

N3139

N3136

N3111 N3112 N3113 N3114 N3115 N3116 N3117 N3118 N3141

N3311

N3216

N3217

N3219

N3218 N3221

N3221C N3221D

N3220F

N3119 N3123N3124N3125

N3126

N3128

N3129

N3121

N3122 N3120

N3130

N3131

N3132

N3340Y

N3340X

N3313 N3314 N3315 N3316 N3317

N3318

N3319

N3325

N3326

N3327

N3328N3220Y

N3220X

N3140

N3140A

3291Z

3292Z

N3340 N3332

N3151

N3225

N3230

N3350

N3221Y

N3312C N3312B N3312A

N3327Y

3700C

3800B

N3221V

3700B

DN

UP

UP

DOWN

UP

UP

TUNNEL

UP

STAIR #4

OFFICE

STG

/REPR

SAFETY OFC

RAD SAFETY LAB

SAFETY LAB

SAFETY STG

RAD SAFETY OFC

OFC SAFETY OFC

OFC

OFC

ONCL OFC

CLIN ENG SUPPORT

CT SIMULATOR

RAD ONCL RN DESK

SUPPORT

ONCLTREATMT

CT MECH. SPACE

TREATMT

CTRL RM

CT CNTRL RM

MECHANICAL RM

ELEC RM

CNTR CNSOL

HVAC OFC

MECH EQP RM

HVAC FIRE CONTRL

LOCKER RM.

JANITOR

TOILET

ELEC RM

LOCKER RM.

STAIR #3

/STOR.

CENT DIST STG

CENT DIST STK RM

CENT DIST STK RM

ELEV

HVAC MEETING ROOM

LOUNGE

WORK RM

SERV OFC

DIR OFC

HVAC OFFICEHVAC OFFICE

DISTRB

RMSTAFF OFFICE

BREAK RM.

RM

ELEC.

CENT DIST STG

CENT DIST STG

PHARMACY

SERV OFC

TOILET

TELECOM OFFICE

MECHANICAL RM

OFFICE

TELECOM STORE RM

OFFICE

CONF RM

CORRIDOR

CORRIDOR

STORAGE ROOM

VESTIBULE

STORE ROOM

NEURO STG

NEURO STG

NEURO STG

NEURO

CONF RM

VESTIBULE

GEAR RM

ELEV. PIT

CORRIDOR

LOBBY

ELEV. #3 ELEV. #4 ELEV. #5 ELEV. #6 ELEV. #7 ELEV. #8

CHASE

TOILET

TOILET

TOILET

SWITCH GEAR RM

WOMEN

LOBBY

CORRIDOR

WORK RM

MEN'S

MEN'S

WOMEN

LOBBY

ELEV. #9 ELEV. #10 ELEV. #11

TOILET

MEN'S

TOILET

WOMEN

CORRIDOR

COR

BATHROOM

RT SUPPORT RM

OFFICE

OFFICE

OFFICE OFFICE

OFFICE

RESPIRATORY THERAPY

CORRIDOR

SUPPORT

OFFICE

MEN'S

TOILET

WOMEN

CORRIDOR

RECPT AREA

CHASE CHASE

JAN CLST

ELEV. PIT

OFFICE

VEST.

VESTIBULE

CURTAIN

SWITCH

ENVIRONMENTAL

MECH EQP

INTROP

INTROP

INTROP

INTROP

NUC NED

TELECOM

STG

HVAC

CLIN ENG

CLIN ENG

EQUIP

CLIN EN

CLIN ENG

CLIN

RAD ONCL

RAD ONCL

RAD

RAD

RAD

RAD ONCL RAD

RAD ONCL

RAD ONCL

RADRAD ONCL

RAD SAFETY

PREP

RAD CENT

ELECTRICAL

MECHANICAL

RT CYLINDER

RT CLEANIG

CLIN DATA

EQUIP

PHARMACY STOCK ROOM

SERV SPPT.

EQUIP

ROOM

MECHANICAL

VESTIBULE

CENT DIST STG

OR STORE ROOM OR STOCK ROOMOR STOCK ROOM

PHYSICAL PLANT

OFFICE

PHYSICAL PLANT

OFFICE

PHYSICAL PLANT

OFFICE

PHYSICAL PLANT

OFFICE

PHYSICAL PLANT

CONF./PRINT

ROOMPHYSICAL PLANT

OFFICE

INTAKE /

DISCHARGE

WAITING

CORRIDOR

DECON

PUMP CORRIDOR

TREATMENT EXAM

VITAL 1

VITAL 2

NOOK

PATIENT TOILET

JANITOR CLOSET

CORRIDOR

CLEAN SUPPLIES

SOIL HOLDING

EXAM

EXAM

EXAM

CORRIDOR

CONS / OFFICE

CONS / OFFICE

RESIDENT'S

OFFICE

BREAK / LOUNGE

LOCKER

STORAGE

CLOSET

OFFICE

NURSES STATION

BURN / EXAM

TEL TRIAGE

ELECTRICAL

CLOSET

SUPPLY

CHAIN

MGMT

OFFICE

INTERPRETERS OFFICE

ADVANCE

PRACTICE

OFFICE

ADVANCE

PRACTICE

OFFICE

ADVANCE

PRACTICE

OFFICE

ADVANCE

PRACTICE

OFFICE

INTERPRETERS

OFFICE

SOCIAL

WORKS

OFFICE

OFFICE

OFFICE

0120C

0120B

0120A

0119A

0119B

0119C

0231Y

0293Z 0294Z 0295Z 0296Z 0297Z 0298Z

0504A

0402A 0402B

0402Z

0235F

0235X

04030403F

0403E

0403A

0403C

0403B

0504X

0505Y0507Y 0509Z 0510Z 0511Z

0509 0508 0506X

0628A

0640A

0636A

0635E

0635D

0635C

0635A0635B

0635G

0411A

0514A

0516A 0516B

0516F

0516E 0516D 0516C

0524H

0524G

0524F

0524B

0522A

0410B

0410A

0408B0408C

0408A

0404A

0801X

0504B

0291Z

0292Z

0524I

0405A

0803A

0115A 01170115

0524E

0524D

0524H

0524J

0524A 0524C

0316A

0320 0319

0329 0604

0601A

0601B

0315A

0613B

0613A

0329A

0220A

BATTERY

CHARGING

MECH EQUIP

RM

CLINICAL

ENGINEERING

SHEET METAL

SHOP

LOCKERS

WOMENS

JANITOR

CLOSET

CORRIDOR

CORRIDOR

STORES

OFFICE

MAINTENENCE

STORES

CONSTRUCTION

CREW

WOMENS

PLUMBING

SHOP

PLUMBING

SHOP

CORRIDOR

STAIRWAY

#1CHASE

MENS

TOILET

ELEVATOR

#23

FREIGHT

ELEVATOR

#22

CORRIDOR

LOCKER

RM.

HVAC

STORAGE

O F F

IC

E

C O N S T.

C R E W

TOILET

STORES

STORAGE

ENVIR.

SERVICES

STORAGE

GROUNDS

LABORERS

G R O U N D S

LA

B O R E R S

B R E A K

R O O M

PLUMBING

OFFICE

SWITCHGEAR

ROOM

006B

006A

009A

B

A

013 002

001A

018Z

015X 015Y

016A

A

006C

F.E.CF.E.C

Fridge

Fridge

36x72 Table

U.C.

D.WASHER

36x72 Table

36x72 Table

36x72 Table

36x72 Table

SCALE

DN

UP

COMPRESSED

GAS

CORRIDOR

MECHANICAL

ROOM

COMPRESSED

GASFLAMMABLE

MATERIALS

FLAMMABLE

MATERIALS

CORRIDOR

LINEN

STORAGE

LINEN

STORAGE

LINEN

OFFICE

CLEAN

LINEN

DIRTY

LINEN

LINEN

STORAGE

TRASH

ROOM

BREAK

ROOM

MEN'S

ROOM

WOMEN'S

ROOM

LOADING

DOCK

SORTING

RECEIVING

RECEIVING

OFFICE

BULB

STORAGE

CHEMO

STORAGE

CONFIDATA

ROOM

MAIL ROOM

OFFICE

MAIL

ROOM

REC. MGR.

OFFICE

PHARMA

WASTE

C H

A S

E

STAIRWELL #1

LOBBY

ELEVATOR

#22

ELEVATOR

#23

102A

117A

121A

121B

100 1 Y

118X

118Z

101Z

USE THIS FREIGHT ELEVATOR BANK

FOR RPM SCOPE OF WORK IN EAST

SIDE OF THE HOSPITAL. TAKE

ELEVATORS DOWN TO BASEMENT

ACCESS ROUTE TO DUMPSTER.

COORDINATE SPECIFIC CAB TO BE

USED WITH THE OWNER.

USE THIS ELEVATOR BANK FOR RPM

SCOPE OF WORK IN WEST SIDE OF

THE HOSPITAL. TAKE ELEVATORS

DOWN TO BASEMENT TO ACCESS

ROUTE TO DUMPSTER. COORDINATE

SPECIFIC CAB TO BE USED WITH THE

OWNER.

TRAVEL ROUTE:

ROUTE TO UNIVERSITY

HOSPITAL FREIGHT

ELEVATOR FOUND ON 3RD,

5TH AND 6TH FLOOR

USE THIS ELEVATOR BANK

FOR RPM SCOPE IN

CONCENTRATED CARE

CENTER AND EAST TOWER.

TAKE ELEVATORS DOWN TO

THE 3RD, 5TH OR 6TH FLOOR

AND CROSS OVER TO

UNIVERSITY HOSPITAL.

USE THIS FREIGHT ELEVATOR BANK

FOR RPM SCOPE IN THE UNIVERSITY

HOSPITAL. TAKE ELEVATORS DOWN

TO BASEMENT ACCESS ROUTE TO

DUMPSTER. COORDINATE SPECIFIC

CAB TO BE USED WITH THE OWNER.

LEGEND

VERTICAL TRANSPORTATION

1. THERE IS AN ELEVATOR CORE IN EACH BUILDING THAT CAN BE USED FOR

MOVING CONSTRUCTION MATERIALS AND WASTE WITHIN THE BUILDING. SEE

ELEVATOR LOCATION PLANS FOR LOCATION OF ELEVATOR TO USE.

ROUTE

LOCATION OF ELEVATORS

2. TRAVEL ROUTES ARE DIAGRAMMATIC.

3. ONLY USE ELEVATORS AS INDICATED. COORDINATE WITH OWNER ON SPECIFIC CAB

TO BE USED

DUMPSTER LOCATION

4. COORDINATE WITH OWNER FOR ALL CARD ACCESS REQUIREMENTS

FREIGHT ELEVATOR BANK

LOCATED IN EAST SIDE OF

THE HOSPITAL

TRAVEL ROUTE:

TAKE TUNNEL FROM

UNIVERSITY HOSPITAL TO

BASEMENT OF

COMPUTER WAREHOUSE

ELEVATOR BANK LOCATED

IN WEST SIDE OF THE

HOSPITAL

TUNNEL ACCESS TO

COMPUTER WAREHOUSE

ELEVATOR BANK LOCATED IN

COMPUTER WAREHOUSE, TAKE UP

TO 1ST FLOOR.

TRAVEL ROUTE:

TUNNEL FROM UNIVERSITY HOSPITAL

TO COMPUTER WAREHOUSE

BASEMENT

TRAVEL ROUTE:

FROM ELEVATOR TO

DUMPSTER

CARD ACCESS.

COORDINATE

WITH OWNER

CARD ACCESS.

COORDINATE

WITH OWNER

UPSTATE PROVIDED

DUMPSTERS

ELEVATOR

BANK

1" = 50'-0"

UNIVERSITY HOSPITAL ELEVATOR LOCATION

1/32" = 1'-0"

PARTIAL CONCENTRATED CARE CENTER AND EAST TOWER FLOOR WASTE REMOVAL LOGISTIC PLAN

1/32" = 1'-0"

PARTIAL BASEMENT UNIVERSITY HOSPITAL WASTE REMOVAL LOGISTIC PLAN

1/32" = 1'-0"

COMPUTER WAREHOUSE BASEMENT

1/32" = 1'-0"

COMPUTER WAREHOUSE 1ST FLOOR

CW

UH

ET

TRUE

NORTH

Th e

C o p yr ig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c

R e p ro d u c tio n o r u se f o r a n y p u rp o se o th e r th a n t h a t a u th o ri ze d b y S ta n te c is f o rb id d e n

Th e

C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.

D

O N

O T sc a le t h e d ra w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o

S ta n te c w ith o u t d e la y

C o p yr ig h t R e se rv e d

ORIGINAL SHEET - ARCH D

Is su e d

/R e v is io n

B y

A p p d

Y Y

Y Y

.M M

.D D

A

2 3 4 5

B

C

D

C o n su lt a n ts

Permit/Seal

Revision:

Project No.:

Title

Scale:

Drawing No.

A R C H

IT

E C

TU

R E

R A

ZA

K

A

SS

O C

IA

TE

S

E

A

ST

A V

E

R O

C H

ES

TE

R N

Y

E L E C

TR

IC

A L

W A

TS

N

EN

G

IN

EE

R

IN

G P

C

S

TA

TE

R

O U

TE

A P

A

LA

C H

IN

N Y

Key Plan

Is su e d f o r B id R

A

ZA

K

.0 7.

A

D D

E N

D U

M

R A

ZA

K

.0

8.

/1

/2

:3

:0

A

M

As indicated

151299 / 1572 CCC &

UH ED Weapon Detection System and Pressure Monitor Replacement

UPSTATE MEDICAL

UNIVERSITY

750 E Adams St, Syracuse, NY 13210

191506670

G-108

RPM WASTE LOGISTICS

PLANS

D a te

WORK DEFINITION

EXISTING (E)

REMOVE EXISTING (D)

NEW WORK (N)

FUTURE

REMOVE EXISTING EQUIPMENT (D)

KEY NOTE###

EQUIPMENT IDENTIFICATION (SIZE MAY VARY)

CONNECTION TO EXISTING

DISCONNECT (CUT AND CAP)

RELOCATE (R)(R)

TEMPORARY, AS NOTED

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

C op yr ig ht R es er ve d

ORIGINAL SHEET - ARCH D

Iss ue d/ Re vis io n By

Ap pd

YY

YY

.M M

.D D

A

2 3 4 5

B

C

D

C on su lta nt s

Permit/Seal

Revision:

Project No.:

Title

Scale:

Drawing No.

AR

CH

ITE

CT

UR

E

RA

ZA

K

AS

SO

C

IA

TE

S

EA

ST

A

VE

RO

C

HE

ST

ER

, N Y

EL

EC

TR

IC

AL

W

AT

SO

N

EN

G

IN

EE

RI

NG

, P C

S

TA

TE

R

O

UT

E

AP

AL

AC

HI

N, N Y

Key Plan

8/ 7/

0:

:1

A

M

St an te c

C on su ltin g Se rv ic es In c.

C om m er ci al

St re et Su ite

Ro ch es te r, NY

-1

Te l: (

5)

-1 w w w

.st an te c.

co m

151299 / 1572 CCC &

UH ED WEAPON

DETECTION SYSTEM AND

PRESSURE MONITOR

REPLACEMENT

UPSTATE MEDICAL

UNIVERSITY

750 E ADAMS STREET

SYRACUSE, NY 13210

191506670

E-000

ELECTRICAL LEAD SHEET

(1 of 2)

ELECTRICAL NOTES

GENERAL

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

INFORMATION SHOWN ON THE ELECTRICAL LEAD SHEETS THAT ARE NOT

REFERENCED ELSEWHERE IN THE CONTRACT DOCUMENTS MAY NOT BE

PERTINENT TO THIS PROJECT, HOWEVER, ADDITIONAL SYMBOLS MAY BE

SPECIFIED WITHIN THE CONTRACT DOCUMENTS.

THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS

FROM AUTHORITIES HAVING JURISDICTION AND PAY ALL ASSOCIATED FEES.

CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO

BEGINNING WORK.

LOCATE JUNCTION AND PULL BOXES AS REQUIRED TO ALLOW ACCESS AFTER

EQUIPMENT AND APPURTENANCES ARE INSTALLED. COORDINATE EXACT

LOCATIONS WITH THE OTHER TRADES. COORDINATE LOCATIONS AND

ELEVATIONS OF ELECTRICAL DEVICES WITH ALL DESIGN DRAWINGS AND

OTHER TRADES PRIOR TO INSTALLATION.

PROTECT PERMANENT BUILDING FINISHES FROM DAMAGE DURING

CONSTRUCTION PERIOD. PROVIDE PLYWOOD OR SIMILAR MATERIAL UNDER

EQUIPMENT OR MATERIALS STORED ON FLOORS, AND IN AREAS WHERE

CONSTRUCTION MAY DAMAGE FINISHES. SURFACES OR FINISHES DAMAGED

DURING CONSTRUCTION SHALL BE REPLACED AT THE COST OF THE

CONTRACTOR AT FAULT.

CONTRACTORS SHALL COORDINATE LOCATIONS OF FIXTURES AND

ELECTRICAL DEVICES INSTALLED IN OR ON THE CEILING WITH

ARCHITECTURAL REFLECTED CEILING PLAN. CEILING MOUNTED ELECTRICAL

DEVICES SHALL BE MOUNTED IN THE CENTER OF THE CEILING TILES, UNLESS

OTHERWISE NOTED.

WHERE DIRECTED TO USE OR RETAIN EXISTING CIRCUITS, AND THE CIRCUIT

NUMBERS DIFFER FROM THE DRAWING, UPDATE DIRECTORIES AND RECORD

DRAWINGS.

PROPERLY SUPPORT CABLING NOT IN CONDUIT PER CODE. IN AREAS SUCH

AS CORRIDORS DESIGNATED FOR NEW CEILINGS AND FINISHES, SUPPORT

EXISTING ELECTRICAL DEVICES AND EQUIPMENT IN AND ABOVE THE CEILING,

INCLUDING CONDUIT AND CABLING. PROVIDE PROPER PERMANENT SUPPORT

AS NEEDED TO COMPLY WITH CODE AND TAKE WEIGHT OFF CEILING

SUPPORTS. CABLING LOCATED IN EXPOSED STRUCTURE (CEILING) AREAS

SHALL BE INSTALLED IN RACEWAY SYSTEM (OR LOOSE IF APPLICABLE) AND

ROUTED TIGHT TO STRUCTURAL MEMBERS AND AS HIGH AS POSSIBLE. ALL

CABLING, LOOSE CABLING (NOT WITHIN A RACEWAY SYSTEM) OR WITHIN

RACEWAY, SHALL BE INSTALLED GROUPED, FOLLOWING THE

ARCHITECTURAL BUILDING LINES AND IN A PROFESSIONAL AND SKILLFUL

MANNER.

REMOVE AND REINSTALL ELECTRICAL DEVICES AND EQUIPMENT AS NEEDED

FOR PAINTING, WALL COVERINGS, CEILINGS, AND FINISH WORK. REFER TO

ARCHITECTURAL DRAWINGS.

WHERE PROJECT PHASING IS INDICATED IN ANY PART OF THE WORKING

DOCUMENT PACKAGE, ELECTRICAL CONTRACTOR IS TO PLAN WORK SO AS

TO FACILITATE SUCH PHASING.

FOR BRANCH CIRCUITS OVER 75 ’ (25 METERS) IN LENGTH (TOTAL ONE WAY)

FROM THE PANEL, THE ELECTRICAL CONTRACTOR SHALL CALCULATE THE

VOLTAGE DROP AND PROVIDE AN APPROPRIATE CONDUCTOR SIZE TO

ACHIEVE NO MORE THAN 3% MAXIMUM ALLOWABLE VOLTAGE DROP.

DO NOT SCALE THE DRAWINGS. BECAUSE OF THE SCALE OF THE DRAWINGS,

IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS OR OTHER SIMILAR

ITEMS WHICH MAY BE REQUIRED TO MAKE A COMPLETE OPERATING SYSTEM.

CAREFULLY INVESTIGATE CONDITIONS AFFECTING WORK AND INSTALL WORK

IN SUCH MANNER THAT INTERFERENCES BETWEEN PIPES, CONDUITS, DUCTS,

EQUIPMENT, ARCHITECTURAL AND STRUCTURAL FEATURES SHALL BE

AVOIDED.

CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO

BEGINNING WORK.

ALL AREAS OF THE BUILDING AFFECTED BY ELECTRICAL DEMOLITION WORK

SHALL BE PATCHED AND REPAIRED TO MATCH ADJACENT FINAL FINISHES

AND REQUIRED FIRE RATING. THE REPAIR WORK SHALL BE DONE TO THE

OWNER'S SATISFACTION.

COORDINATE WITH MECHANICAL CONTRACT DOCUMENTS FOR ADDITIONAL

SCOPE OF WORK FOR SYSTEMS TO BE REMOVED OR RETAINED TO EXTENT

REQUIRED TO PERFORM NEW CONSTRUCTION ACTIVITIES INDICATED. PATCH

BUILDING FINISHES WHERE ELECTRICAL ITEMS ARE REMOVED AND

ADJACENT EXISTING FINISH IS TO REMAIN.

DEMOLITION

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

ANY EXISTING WIRING SERVING DEVICES TO REMAIN IN SERVICE, AND WHICH IS

INTERRUPTED BY WORK PERFORMED UNDER THIS CONTRACT, SHALL BE

REROUTED TO MAINTAIN CIRCUIT CONTINUITY. CONTRACTOR SHALL ASSUME THE

RISK OF MAINTAINING EXISTING SYSTEMS EXCEPT RELOCATION OF WIRING OF #2

AWG AND LARGER SHALL BE CONSIDERED AN ADDITIONAL COST IF NOT SHOWN TO

BE RELOCATED. IF SUCH WIRING IS FOUND THE CONTRACTOR SHALL NOTIFY THE

OWNER OF WIRING LOCATION, INDICATE THE REASON IT MUST BE REMOVED AND

COST OF RELOCATION AND RECEIVE THE OWNER'S APPROVAL BEFORE

PROCEEDING WITH THE WORK. PRIOR TO COMMENCING WITH DEMOLITION,

IDENTIFY ALL POWER, LIGHTING, COMMUNICATION, AND SIGNAL CIRCUITS PASSING

THROUGH THE DEMOLITION AREA OR EXTENDING BEYOND THE DEMOLITION AREA.

COORDINATE WITH DEMOLITION WORK OF OTHER TRADES.

THE EXISTING BUILDING MUST BE KEPT IN OPERATION AT ALL TIMES. MAINTAIN

ELECTRICAL SERVICES AND SYSTEMS AT ALL TIMES TO AREAS BEYOND THE

CONSTRUCTION AREA AND MAINTAIN CONTINUITY OF FIRE ALARM, LIFE SAFETY

AND SECURITY SYSTEMS TO ALL OCCUPIED AREAS OF THE BUILDING

THROUGHOUT THE CONSTRUCTION PERIOD. PROVIDE TEMPORARY WIRING AND

BRANCH CIRCUITING AS NECESSARY TO MAINTAIN OPERATION OF EXISTING

CIRCUITS AND SYSTEMS EXTENDING BEYOND REMODEL AREA. RECONNECT ANY

SERVICES WHICH ARE TO REMAIN, AND WHICH HAVE BEEN DISCONNECTED DURING

DEMOLITION OR CONSTRUCTION. ARRANGE WORK IN SUCH A MANNER THAT

INTERRUPTIONS IN SERVICES OCCUR ONLY AT PRE-SCHEDULED TIMES. CARRY

OUT THE WORK WITH A MINIMUM OF NOISE, DUST AND DISTURBANCE.

PERMANENTLY REMOVE ABANDONED ELECTRICAL EQUIPMENT, LIGHTING

FIXTURES, ELECTRICAL DEVICES, POWER AND SIGNALING WIRING DEVICES AND

ASSOCIATED WIRE, RACEWAYS, AND/OR JUNCTION BOXES. THE REMOVAL OR

RELOCATION OF EXISTING ELECTRICAL EQUIPMENT PRESENTLY CONCEALED IN

EXISTING CONSTRUCTION SHALL BE COORDINATED WITH THE OWNER PRIOR TO

REMOVAL OR RELOCATION. RACEWAYS AND CONDUCTORS SHALL BE REMOVED

BACK TO THE SOURCE OR NEAREST REMAINING JUNCTION BOX OR DEVICE AS FAR

AS PRACTICAL, OR WHERE COMPLETE REMOVAL NOT PRACTICAL, RENDERED

PERMANENTLY SAFE.

ANY EXISTING SYSTEM OUTAGES SHALL BE OF MINIMUM DURATION AND AT A TIME

ACCEPTABLE TO THE OWNER, ARRANGED A MINIMUM OF 10 WORKING DAYS IN

ADVANCE. LONGER NOTICES AND/OR ADDITIONAL RESTRICTIONS PERTAINING TO

OUTAGES MAY BE REQUIRED IN SOME INSTANCES, AS PER SPECIFICATIONS.

VERIFY PROTOCOL WITH ALL PROJECT STAKEHOLDERS INCLUDING OWNER,

TENANT, CONSTRUCTION MANAGER AND/OR USER GROUP(S) AS APPLICABLE.

IN THE EVENT THAT DEMOLITION WORK AFFECTS THE STRUCTURAL SUPPORT OF

EXISTING ELECTRICAL EQUIPMENT THAT IS TO REMAIN IN SERVICE, IT SHALL BE

RE-SUPPORTED IN ACCORDANCE WITH ALL APPLICABLE CODES. PROVIDE

TEMPORARY SUPPORTS WHERE REQUIRED.

UNUSED FLUSH MOUNTED DEVICES, OUTLET AND OTHER BOXES IN FINISHED

AREAS SHALL BE REMOVED FROM WALL AND THE REMAINING HOLE PATCHED TO

MATCH ADJACENT WALL SURFACES. UNUSED RACEWAYS AND SLEEVES SHALL BE

CUT FLUSH AT CEILING, FLOOR OR WALL AND FILLED WITH GROUT OR REQUIRED

FIRE SEALANT. UNUSED RACEWAYS ABOVE ACCESSIBLE CEILINGS SHALL BE

REMOVED.

ELECTRICAL MATERIAL SCHEDULED FOR REMOVAL IS TO BE REMOVED FROM THE

SITE AND PROPERLY DISPOSED OF AS PART OF THIS CONTRACT. ANY ELECTRICAL

MATERIAL THE OWNER WISHES TO RETAIN TO BECOME THE PROPERTY OF THE

OWNER AND TO BE REMOVED AND PLACED AT A LOCATION ON THE SITE AS

DIRECTED BY THE OWNER.

THE DEMOLITION DRAWINGS SHOW THE GENERAL SCOPE OF THE DEMOLITION AND

NOT EXACT DETAILS OR TOTAL EXTENT. FOR EXACT DETAILS AND TOTAL EXTENT,

EACH SYSTEM MUST BE CAREFULLY CHECKED ON SITE. BEFORE REMOVING

SYSTEMS FOLLOW THE SERVICE THROUGH TO ENSURE OTHER AREAS OF THE

BUILDING ARE NOT AFFECTED.

ALL AREAS OF THE BUILDING AFFECTED BY ELECTRICAL DEMOLITION WORK SHALL

BE PATCHED AND REPAIRED TO MATCH ADJACENT FINAL FINISHES. THE REPAIR

WORK SHALL BE DONE TO THE OWNER REPRESENTATIVE'S SATISFACTION.

DEMOLITION WORK SHALL INCLUDE REMOVAL OF EXISTING BUILDING

CONSTRUCTION TO EXTENT REQUIRED TO PERFORM NEW CONSTRUCTION

ACTIVITIES INDICATED.

THE DEMOLITION PROCEDURES SHALL PROVIDE FOR SAFE CONDUCT OF THE

WORK, PROTECTION OF PERSONNEL, CAREFUL REMOVAL AND OTHER DISPOSITION

OF MATERIALS SPECIFIED TO BE SALVAGED. PROTECTION OF PROPERTY TO

REMAIN UNDISTURBED, COORDINATION WITH OTHER WORK IN PROGRESS, AND

TIMELY DISCONNECTION OF UTILITY SERVICES.

EXISTING WORK SHALL BE CUT, DRILLED, ALTERED, REMOVED, OR TEMPORARILY

REMOVED AND REPLACED FOR PERFORMANCE OF WORK UNDER THE CONTRACT.

WORK REPLACED SHALL MATCH SIMILAR EXISTING WORK. STRUCTURAL MEMBERS

OF CONCRETE OR STRUCTURAL STEEL SHALL NOT BE CUT OR ALTERED, EXCEPT

AS SHOWN, WITHOUT AUTHORIZATION OF THE ENGINEER. WORK REMAINING IN

PLACE DAMAGED OR DEFACED DURING THIS CONTRACT SHALL BE RESTORED TO

THE CONDITION AT TIME OF AWARD OF CONTRACT. CUT, ALTER, REMOVE, OR

TEMPORARILY REMOVE AND REPLACE EXISTING WORK FOR INSTALLATION OF

ELECTRICAL WORK.

UNLESS SPECIFIED OTHERWISE, ALL PIPING, WIRING, CONDUIT, AND OTHER

DEVICES ASSOCIATED WITH THE EQUIPMENT NOT RE-USED IN THE NEW WORK

AREA SHALL BE COMPLETELY DEMOLISHED AND REMOVED FROM THE PROPERTY.

THIS INCLUDES ALL CONCRETE PADS, PIPE, VALVES, FITTINGS, INSULATION, AND

ALL HANGERS, INCLUDING THE TOP CONNECTION AND ANY FASTENINGS TO

BUILDING STRUCTURAL SYSTEMS. ALL OPENINGS SHALL BE SEALED AFTER

REMOVAL OF EQUIPMENT, PIPES, DUCTS, AND OTHER PENETRATIONS IN ROOF,

WALLS, FLOORS, IN AN APPROVED MANNER. STRUCTURAL INTEGRITY OF THE

BUILDING SYSTEM SHALL BE MAINTAINED.

ANY CAT 5 CABLES TO BE DEMOLISHED SHALL BE CUT AT THE BOX AND COILED

ABOVE THE CEILING FOR FUTURE USE.

ALL WALL MOUNTED DEVICES INSTALLED ON EXISTING WALLS TO BE REMOVED

SHALL ALSO BE REMOVED.

ALL CEILING MOUNTED DEVICES INSTALLED ON CEILINGS TO BE REMOVED SHALL

ALSO BE REMOVED.

IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN CIRCUIT CONTINUITY OF

ALL EQUIPMENT, FIXTURES, OUTLETS, AND THE LIKES THAT ARE EXISTING TO

REMAIN UNLESS OTHERWISE NOTED.

ABBREVIATIONS

#/C MULTI-CONDUCTOR, # INDICTATES QUANTITY

(D) DEMOLISH

(E) EXISTING

(N) NEW

(R) EXISTING TO BE RELOCATED

1/C SINGLE CONDUCTOR

A AMPS

A/C AIR CONDITIONING UNIT

AC ALTERNATING CURRENT

ACH ABOVE COUNTER HEIGHT

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

ADJ ADJUSTABLE

AF AMP FRAME, AMP FUSE

AFC ABOVE FINISHED CEILING

AFCI ARC FAULT CIRCUIT INTERRUPTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

AIC AMPERE INTERRUPTING CAPACITY

AL ALUMINUM

ALD ASSISTED LISTENING DEVICE

ALT ALTERNATE

ARCH ARCHITECTURAL

AS AMP SWITCH

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

AVG AVERAGE

AWG AMERICAN WIRE GAUGE

BC BONDING CONDUCTOR

BCU BARE COPPER

BFC BELOW FINISHED CEILING

BFG BELOW FINISHED GRADE

BKR BREAKER

BLDG BUILDING

BOF BOTTOM OF FIXTURE

BOH BACK OF HOUSE

BTM BOTTOM

C CONDUIT

C/W COMPLETE WITH

CAP CAPACITY

CATV COMMUNITY ANTENNA TELEVISION

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CEC CANADIAN ELECTRIC CODE

CFOI CONTRACTOR FURNISHED, OWNER INSTALLED

CIRC CIRCULATING

CKT CIRCUIT

CL CENTERLINE

CLG CEILING

CM CEILING MOUNTED

CMU CONCRETE MASONRY UNIT

CO CONDUIT ONLY

COMM COMMUNICATIONS

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACTOR

CPT CONTROL POWER TRANSFORMER

CPU CENTRAL PROCESSING UNIT

CR CRITICAL BRANCH

CT CURRENT TRANSFORMERS

CTR CENTER

CU COPPER

CUH CABINET UNIT HEATER

D DEDICATED

DALI DIGITAL ADDRESSABLE LIGHTING INTERFACE

DC DIRECT CURRENT

DET DETAIL

DIA DIAMETER

DIM DIMENSION

DISC DISCONNECT

DIV DIVISION

DL DAMP LOCATION

DMX DIGITAL MULTIPLEX

DMX-RDM DIGITAL MULTIPLEX REMOTE DEVICE

MANAGEMENT

DN DOWN

DP DISTRIBUTION PANEL

DPDT DOUBLE POLE, DOUBLE THROW

DPR DAMPER

DPST DOUBLE POLE, SINGLE THROW

DWG DRAWING

DWH DOMESTIC WATER HEATER

EA EACH

EC ELECTRICAL CONTRACTOR

EF EXHAUST FAN

ELEC ELECTRICAL

ELEV ELEVATOR

EM EMERGENCY

EM GEN EMERGENCY GENERATOR

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EP ELECTRIC-PNEUMATIC

EPO EMERGENCY POWER OFF

EQ EQUIPMENT BRANCH

EQUIP EQUIPMENT

ABBREVIATIONS

ETD EMERGENCY TRANSFER DEVICE

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXP EXPLOSION PROOF

EXTER EXTERIOR

F&I FURNISHED AND INSTALLED

FA FIRE ALARM

FAA FIRE ALARM ANNUNCIATOR

FACP FIRE ALARM CONTROL PANEL

FB FLOOR BOX

FCU FAN COIL UNIT

FF FUSE FRAME

FLR FLOOR

FLUOR FLUORESCENT

FO FIBER (FIBRE) OPTIC

FOH FRONT OF HOUSE

FP FIRE PROTECTION

FPC FORWARD PHASE CONTROL

FS FUSIBLE SWITCH

FSCS FIRE FIGHTER SMOKE CONTROL STATION

FVNR FULL VOLTAGE NON REVERSING

FVR FULL VOLTAGE REVERSING

G, GND GROUND

G/Y GREEN YELLOW

GA GAUGE

GAL GALLONS

GC GENERAL CONTRACTOR

GEN GENERATOR

GFCI GROUND FAULT (CIRCUIT) INTERRUPTER

GFI GROUND FAULT INDICATOR

H HOT CONDUCTOR

HC HORIZONTAL CROSS CONNECT

HD HAND DRYER

HFF HANDS FREE FIXTURE

HH HANDHOLE

HID HIGH INTENSITY DISCHARGE

HK HOUSE KEEPING PAD

HM HORIZONTALLY MOUNTED

HOA HAND-OFF-AUTO

HOR HORIZONTAL

HP HORSEPOWER

HT HEIGHT

HTG HEATING

HV HIGH VOLTAGE

HVCB HIGH VOLTAGE CIRCUIT BREAKER

HW HOT WATER

HZ HERTZ

IC INTERMEDIATE CROSS CONNECT

ID INSIDE DIAMETER

IDF INTERMEDIATE DISTRIBUTION FRAME

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

INST INSTANTANEOUS

IP INTERNET PROTOCOL

JB JUNCTION BOX

K KIRK KEY INTERLOCK

KAIC KILO-AMPS INTERRUPTING CAPACITY

KV KILOVOLT

KVA KILOVOLT-AMPERES

KW KILOWATT

LED LIGHT EMITTING DIODE

LR LEGALLY REQUIRED

LS LIFE SAFETY BRANCH

LSIG LONG TIME, SHORT TIME, INSTANTANEOUS,

GROUND FAULT

LTG LIGHTING

LV LOW VOLTAGE

MAU MAKE UP AIR UNIT

MAX MAXIMUM

MC METAL CLAD CABLE

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MCCB MOLDED CASE CIRCUIT BREAKER

MCP MOTOR CIRCUIT PROTECTOR

MCT MAIN CROSS CONNECT

MDF MAIN DISTRIBUTION FRAME

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MET MAIN EARTHING TERMINAL

MFR MANUFACTURER

MH MAINTENANCE HOLE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUG ONLY

MM MULTIMODE FIBER (FIBRE) OPTIC STRAND

MSB MAIN SWITCHBOARD

MTD MOUNTED

MTG MOUNTING

MTS MAIN TERMINAL SPACE

MV MEDIUM VOLTAGE

MVCB MEDIUM VOLTAGE CIRCUIT BREAKER

MW MICROWAVE OVEN

N NEUTRAL

NAC NOTIFICATION APPLIANCE CIRCUIT

NC NORMALLY CLOSED

NEC NATIONAL ELECTRIC CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

ABBREVIATIONS

NO NORMALLY OPEN

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED

OFE OWNER FURNISHED EQUIPMENT

OH OVERHEAD

OL OVERLOAD

OS OCCUPANCY SENSOR, OPTIONAL STANDBY

OSP OUTSIDE PLANT

P POLE

PA PUBLIC ADDRESS

PB PULL BOX

PD PUNCHDOWN

PF POWER FACTOR

PH, Ø PHASE

PMH PRIMARY MAINTENANCE HOLE

PNL PANEL

POE POINT OF ENTRANCE

POS POINT OF SERVICE

PR PAIR

PT POTENTIAL TRANSFORMERS

PTS PNEUMATIC TUBE STATION

PTZ PAN/TILT/ZOOM

PV PHOTOVOLTAIC

PVC POLYVINYL CHLORIDE

PWR POWER

RA RETURN AIR

REC RECESSED

RECP RECEPTACLE

REQD REQUIRED

REX REQUEST TO EXIT

RM ROOM

RNC RIGID NON-METALLIC CONDUIT

RO RACEWAY ONLY

RPC REVERSE PHASE CUT

RSC, RGS RIGID STEEL CONDUIT

SCCR SHORT CIRCUIT CURRENT RATING

SEC SECURITY

SECT SECTION

SIM SIMILAR

SM SINGLE MODE FIBER OPTIC STRAND

SMH SECONDARY MAINTENANCE HOLE

SMR SURFACE MOUNTED RACEWAY

SPD SURGE PROTECTED DEVICE

SPDT SINGLE POLE DOUBLE THROW

SPECS SPECIFICATIONS

SPST SINGLE POLE SINGLE THROW

SS STAINLESS STEEL

ST SHUNT TRIP

STD STANDARD

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

SYS SYSTEM

TBB TELECOMMUNICATIONS BACKBONE

TC TEMPERATURE CONTROL OR TERMINAL

CABINET

TE TELECOMMUNICATIONS ENCLOSURE

TELE TELEPHONE

TELECOM TELECOMMUNICATIONS

TEMP TEMPERATURE

TERM TERMINAL

TGB TELECOMMUNICATIONS GROUND BAR

TMGB TELECOMMUNICATIONS MAIN GROUND BAR

TMH TELECOMMUNICATIONS MAINTENANCE HOLE

TOF TOP OF FIXTURE

TP TAMPER RESISTANT

TR TELECOMMUNICATIONS ROOM

TSP TWISTED SHIELDED PAIR

TSTAT THERMOSTAT

TTB TELECOM TERMINAL BOARD

TV TELEVISION

TYP TYPICAL

UG UNDERGROUND

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

UNV UNIVERSAL VOLTAGE

UPS UNINTERRUPTIBLE POWER SUPPLY

USB UNIVERSAL SERIAL BUS

UTP UNSHIELDED TWISTED PAIR

UV UNIT VENTILATOR

V VOLTS

VA VOLT-AMPS

VAV VARIABLE AIR VOLUME

VC VOLUME CONTROL

VDT VISUAL DISPLAY TERMINAL

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VIF VERIFY IN FIELD

VOL VOLUME

VT VAPOR TIGHT

W WIRE, WATT

WAP WIRELESS ACCESS POINT

WG WIREGUARD

WL WET LOCATION

WP WEATHERPROOF

WT WATERTIGHT

XFMR TRANSFORMER

ELECTRICAL NOTES

CONTROL PANELS

AMP AMPLIFIER RACK

ARCM AREA OF REFUGE COMMUNICATION MASTER UNIT

ARCR AREA OF REFUGE COMMUNICATION REMOTE UNIT

ACU AUTONOMOUS CONTROL UNIT

AUX AUXILIARY EQUIPMENT PANEL

BATT BATTERY CABINET

CRT CATHODE RAY TUBE

HVAC

CONTROL PANEL FOR HEATING (H), VENTILATION (V),

AIR CONDITIONING (AC), EXHAUST (E),

STAIRWELL PRESSURIZATION (P)

DACR DIGITAL ALARM COMMUNICATOR RECEIVER

DACT DIGITAL ALARM COMMUNICATOR TRANSMITTER

ESR ELEVATOR STATUS RECALL

ECCU EMERGENCY COMMUNICATIONS CONTROL UNIT

FAA FIRE ALARM ANNUNCIATOR

FACP FIRE ALARM CONTROL PANEL

(LEGACY SYMBOL FOR FACU)

FACU FIRE ALARM CONTROL UNIT;

INCLUDE A 'D' SUBSET IF IT IS DEDICATED UNIT

FADC FIRE ALARM DOCUMENTATION CABINET

WKST FIRE ALARM SYSTEM WORKSTATION

FATC FIRE ALARM TERMINAL CABINET

TPRn FIRE ALARM TRANSPONDER n=TRANSPONDER NUMBER

FFI FIREFIGHTER INTERFACE

FSCP

FIRE SUPPRESION CONTROL PANEL

(LEGACY SYMBOL FOR FSCU)

xx DENOTES SUPPRESION TYPE

FSCU FIRE SUPPRESION CONTROL UNIT

xx DENOTES SUPPRESION TYPE

GAP GRAPHIC ANNUNCIATOR PANEL

LCD LCD ANNUNCIATOR / DISPLAY

MFACU MASTER FIRE ALARM CONTROL UNIT

NACn

NOTIFICATION CIRCUIT POWER BOOSTER,

EXTENDER PANEL

n=UNIT NUMBER

POWER PANEL

PRE PREACTION SYSTEM / CONTROL UNIT

PRN PRINTER

PPCU PROTECTED PREMISES CONTROL UNIT (LOCAL)

PP PURGE PANEL

RP RELAY PANEL

RSFACU RELEASING SERVICE FIRE ALARM CONTROL UNIT

MIC REMOTE VOICE EVACUATION MICROPHONE

EVACn REMOTELY LOCATED EVACUATION AMPLIFIER CABINET

SCP SMOKE CONTROL PANEL

SAP SPRINKLER ALARM PANEL

UPS UNITERRUPTIBLE POWER SUPPLY

EVAC VOICE ECAVUATION CONTROL UNIT

WCU WIRELESS CONTROL UNIT

RSFACU AEROSOL

xx xx

A

RSFACU CARBON DIOXIDECO2

RSFACU CLEAN AGENTCA

RSFACU DELUGE FIRE SPRINKLERDL

RSFACU DRY CHECMICALDC

FIRE ALARM CONTROL INTERFACEFACI

FIRE PUMP CONTROLLERFPC

FOAM

HALON

HYBRID (WATER AND INERT GAS)

FIRE-EXTINGUISHING SYSTEM

MASS NOTIFICATION SYSTEM INTERFACEMNS

OPERATING CONTROL UNITOCU

WATER MIST

WET CHECMICAL

RSFACU FO

RSFACU HL

RSFACU HY

RSFACU WM

RSFACU WC

SPECIALTY SYMBOLS

CONTROLS

FUSED SAFETY SWITCH, FUSE RATING INDICATED

NON-FUSED SAFETY SWITCH

COMBINATION MOTOR STARTER AND FUSED SAFETY

SWITCH, FUSE RATING INDICATED

MOTOR STARTER

MANUAL MOTOR STARTER

ENCLOSED CIRCUIT BREAKER

ENCLOSED CONTACTOR

AUTOMATIC DOOR PUSHPLATE

EMERGENCY SHUTDOWN

DEAD FRONT GFCI

DIRECT DIGITAL CONTROL PANEL

RELAY

THERMOSTAT

TIME CLOCK

VARIABLE FREQUENCY DRIVE

PUSH BUTTON CONTROL STATION

DDC

R

TC

VFD

TOGGLE SWITCH, MOTOR RATEDM

T

TOUCHLESS AUTOMATIC DOOR OPENER

TRUE

NORTH

PROJECT

NORTH

GENERAL

DETAIL NUMBER

SHEET NUMBER

DETAIL CALLOUT

SIM#

Sht#

Sht#

EXTERIOR ELEVATION CALLOUT

#REF

Sht# INTERIOR ELEVATION CALLOUT

#REF

#R

EF

#R

EF#REF

Sht#

Sht#

BUILDINGS SECTION CALLOUT

Sht#

SIMSIM

Sht#

WALL SECTION CALLOUT

SIM

LEVEL CALLOUT

NAME

ELEVATION

NORTH ARROW

DRAWING REVISION

MATCH LINE

*SIM=SIMILAR, INDICATING THAT THE REFERENCED

DETAIL IS SIMILAR TO ANOTHER ONE BUT NOT

EXACTLY THE SAME, MEANING IT MIGHT HAVE SLIGHT

VARIATIONS THAT WARRANT A SEPARATE CALLOUT

BUT ARE CLOSE ENOUGH TO BE REFERENCED WITH

THIS LABEL.

# BUILDINGS SECTION CALLOUT

WITH BACK REFERENCE

Sht#1

SIMSIM

Sht#2 Sht#1 Sht#2

RACEWAYS

RACEWAY CONCEALED IN CEILING OR WALL. EXPOSED

RACEWAY IS ALLOWED ONLY WHERE NOTED.

RACEWAY BELOW SLAB OR UNDERGROUND

RACEWAY UP

RACEWAY DOWN

RACEWAY STUB-OUT WITH BUSHING

RACEWAY CONTINUATION

JUNCTION BOX, CEILING OR ABOVE CEILING MOUNTED

PULL BOX

JUNCTION BOX, WALL MOUNTED

J

PB

J

JUNCTION BOX, IN-GROUNDJ

SURFACE RACEWAY (HORIZONTAL/VERTICAL)

CONTROL PANEL; LETTER INDICATES AS FOLLOWS:

M=MOUNT

C-CEILING D-DESK F-FLUSH H-HIDDEN M-MULLION

P-PEDESTAL R-RACK S-SURFACE W-WALL

T=TECHNOLOGY/TYPE

B-BURGLAR D-DOOR F-FIRE P-PERIMETER

M

T

ISS

UE

D

FO

R

BI

D

SR

B

JW

E

.0 7.

AD

DE

ND

UM

SR

B

JW

E

.0

8.

FA-201 FIRE ALARM NEW WORK ENLARGED RCP - CCC 2ND FLOOR

FAD-201 FIRE ALARM DEMOLITION ENLARGED RCP - CCC 2ND FLOOR

FIRE ALARM

E-502 ELECTRICAL SCHEDULES

E-501 ELECTRICAL DETAILS

E-202 ELECTRICAL NEW WORK ENLARGED RCP - CCC 2ND FLOOR

E-201 ELECTRICAL NEW WORK ENLARGED PLAN - CCC 2ND FLOOR

E-113 ELECTRICAL POWER PLAN - UH 8TH FLOOR

E-112 ELECTRICAL POWER PLAN - UH 7TH FLOOR

E-111 ELECTRICAL POWER PLAN - UH 6TH FLOOR

E-110 ELECTRICAL POWER PLAN - UH 4TH FLOOR

E-109 ELECTRICAL POWER PLAN - VE 12TH FLOOR

E-108 ELECTRICAL POWER PLAN - VE 11TH FLOOR

E-107 ELECTRICAL POWER PLAN - VE 10TH FLOOR

E-106 ELECTRICAL POWER PLAN - VE 9TH FLOOR

E-105 ELECTRICAL POWER PLAN - VE 8TH FLOOR

E-104 ELECTRICAL POWER PLAN - CCC 6TH FLOOR

E-103 ELECTRICAL POWER PLAN - CCC 5TH FLOOR

E-102 ELECTRICAL POWER PLAN - CCC 3RD FLOOR

E-101 ELECTRICAL POWER PLAN - CCC 2ND FLOOR

ED-202 ELECTRICAL DEMOLITION ENLARGED RCP - CCC 2ND FLOOR

ED-201 ELECTRICAL DEMOLITION ENLARGED PLAN - CCC 2ND FLOOR

ED-101 ELECTRICAL DEMOLITION PLAN - CCC 2ND FLOOR

E-001 ELECTRICAL LEAD SHEET (2 of 2) E-000 ELECTRICAL LEAD SHEET (1 of 2)

ELECTRICAL

SHEET NUMBER SHEET NAME

SHEET LIST

151299/1572

ADDENDUM 1

AUGUST 13, 2026

Administrative Requirements 013000 - 1

SECTION 013000 - ADMINISTRATIVE REQUIREMENTS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. General administrative requirements.

B. Electronic document…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .