This document contains Questions and Answers related to the federal contract opportunity for "Supply Continuous Panels for Bison Corral Update" with Solicitation Number 140PS124Q0019.

The key details are:

  • The contract is to supply materials to replace 70 continuous fence panels and supporting materials for the update of the Bison Corrals at Badlands National Park.
  • The contractor needs to provide 42-foot long straight pipe and rail connectors to make the panels continuous. The rail connectors are approximately 8 inches long and fit inside the pipe ends to connect the panels.
  • The contractor is only required to cut the 42-foot pipes to size and ship them; no other preparation is needed.
  • Pictures of the required clips/fasteners are provided in attachments 4 and 5.
  • The contracting agency is the Department of the Interior, National Park Service.

View the file

Other files

File Type Posted
Attachment_3_CLIPS_0001.jpg JPG image
Attachment_2_CLIPS_0001.jpg JPG image
Sol_140PS124Q0019_Amd_0001.pdf PDF
Attachment_4_Rail_Connector_Picture_0001.jpg JPG image
Sol_140PS124Q0019.pdf PDF
A04__Bison_Corral_SOW_(updated).docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1 Bison Fence Panels, Badlands National Park, South Dakota

140PS124Q0019

QuestionsAnswers
In reference to the rail connectors to make panels "continuous". Is there a photo or drawing of these or is this something that is up to us to design? I see the existing panels are leaned up against the wood poles and they don't connect well together so I imagine you're trying to fix that issue, correct?Rail connector it is about 8 inches long and it fix's inside the pipe end of the panel you are connecting.. There is a dent in the middle so it only slides half way in on each panel it is connecting. There are 7 per panel (see picture in attachemnt number 3)

We can definitely cut the Qty: 70 of 42' pipe. Is there anything else we need to do with those or are those only needing saw cut and then shipped? Just need cut and shipped. 3 inch new strait pipe 70 of them 42 foot long

In reference to the Clips/ Fasteners - Is there a drawing of these or is this up to us to design as well? Pictures of CLIPS are in attachment 4 and 5.