B09_Solicitation_Amendment_5_Attach_1_NEMA_Box_Specifications_0005.docx

DOCX document 14 KB Posted

Attached to
MORUREPLACE SECURITY GATES Federal contract opportunity
Solicitation number
140P6325Q0011
Issued by
Department of the Interior National Park Service Midwest Region

About this file

This document is a project specification for a NEMA 3 rated enclosure to be installed at Mount Rushmore National Memorial as part of the security gates replacement project. The specification requires a 27" x 22" x 13" marine grade 5052 aluminum enclosure with multiple features including screened airflow vents, dual thermostat/fan combinations, mylar bubble insulation, weathertight rubber door seals, a triangular cam security lock, a removable equipment mounting plate, a built-in sunshade, and a universal pole mounting bracket. The contractor is responsible for rerouting existing network fiber, mounting IT equipment, and ensuring all relocated equipment is properly installed and fully operational in the new enclosure, with the precise installation location to be coordinated with the park in the vicinity of the new gate cabinet.

View the file

Other files for this federal contract opportunity

Other files attached to MORUREPLACE SECURITY GATES, newest first.
File Type Posted
Sol_140P6325Q0011_Amd_0006.pdf PDF
Sol_140P6325Q0011_Amd_0005.pdf PDF
Sol_140P6325Q0011_Amd_0004.pdf PDF
B09_Solicitatoin_Amendment_3_attach_1_Additional_gate_specifications_0003.docx DOCX document
B09_Solicitation_Amendment_3_attach_2_Questions_and_Answers_0003.pdf PDF
Sol_140P6325Q0011_Amd_0003.pdf PDF
Sol_140P6325Q0011_Amd_0002.pdf PDF
Sol_140P6325Q0011_Amd_0001.pdf PDF
Sol_140P6325Q0011.pdf PDF
B08_Solicitation_attach_2_Wage_Determination.pdf PDF
B08_Solicitation_attach_3_Experience_Questionaire.xls XLS spreadsheet
B08_Solicitation_attach_1_SPECS_.docx DOCX document
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Specifications New 27” x 22” x 13” NEMA 3 Contractor shall provide all labor and materials to install a new 27” x 22” x 13” NEMA 3 rated enclosure for IT equipment currently housed in the existing gate cabinet. New enclosure shall be marine grade 5052 aluminum and be equipped with: front and side screened airflow vents, two thermostat/fan combinations, dual layered mylar bubble insulation for enhanced interior climate control, ¼” weathertight rubber door seals, a triangular cam security lock, a removeable and adjustable blank equipment mounting plate, a built-in sunshade that acts as a barrier between the materials of the enclosure and the direct sunlight, and a universal mounting bracket for pole installation. Exact location of pole installation to be coordinated with the park but will be in the immediate vicinity of the new gate cabinet. Contractor shall ensure existing network fiber is rerouted to the new enclosure and all relocated IT equipment in the new enclosure is properly mounted, wired, routed, and fully operable in its designed intent.

File details come from the government source that posted it. Updated .