JANUARY 2018 DOOR HARDWARE (DESCRIPTIVE SPECIFICATION)
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 1
CAMPUS DOOR ACCESS CONTROL
SECTION 087111 - DOOR HARDWARE (DESCRIPTIVE SPECIFICATION)
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section includes:
1. Mechanical door hardware for the following:
a. Swinging doors.
2. Cylinders for door hardware specified in other Sections.
3. Electrified door hardware.
B. Related Requirements:
1. Section 081213 "Hollow Metal Doors and Frames" for integral intumescent seals provided as part of labeled fire-rated assemblies.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product indicated. Include construction and installation details, material descriptions, dimensions of individual components and profiles, and finishes.
B. Shop Drawings: Details of electrified door hardware, indicating the following:
1. Wiring Diagrams: For power, signal, and control wiring and including the following:
a. Details of interface of electrified door hardware and building safety and security systems.
2. Operation Narrative: Describe the operation of doors controlled by electrified door hardware.
C. Other Action Submittals:
1. Door Hardware Schedule: Prepared by or under the supervision of Installer, detailing fabrication and assembly of door hardware, as well as installation procedures and diagrams. Coordinate final door hardware schedule with doors, frames, and related work to ensure proper size, thickness, hand, function, and finish of door hardware.
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 2
CAMPUS DOOR ACCESS CONTROL
a. Submittal Sequence: Submit door hardware schedule concurrent with submissions of Product Data, Samples, and Shop Drawings. Coordinate submission of door hardware schedule with scheduling requirements of other work to facilitate the fabrication of other work that is critical in Project construction schedule.
b. Format: Comply with scheduling sequence and vertical format in DHI's "Sequence and Format for the Hardware Schedule." Double space entries, and number and date each page.
c. Content: Include the following information:
1) Identification number, location, hand, fire rating, size, and material of each door and frame.
2) Locations of each door hardware set, cross-referenced to Drawings on floor plans and to door and frame schedule.
3) Complete designations, including name and manufacturer, type, style, function, size, quantity, function, and finish of each door hardware product.
4) Description of electrified door hardware sequences of operation and interfaces with other building control systems.
5) Fastenings and other pertinent information.
6) Explanation of abbreviations, symbols, and codes contained in schedule.
7) Mounting locations for door hardware.
8) List of related door devices specified in other Sections for each door and frame.
1.4 INFORMATIONAL SUBMITTALS
A. Qualification Data: For Installer.
B. Product Certificates: For electrified door hardware, from the manufacturer.
C. Warranty: Special warranty specified in this Section.
1.5 CLOSEOUT SUBMITTALS
A. Maintenance Data: For each type of door hardware to include in maintenance manuals. Include final hardware schedule.
1.6 QUALITY ASSURANCE
A. Installer Qualifications: Supplier of products and an employer of workers trained and approved by product manufacturers and an Architectural Hardware Consultant who is available during the course of the Work to consult with Contractor and Government about door hardware and keying.
1. Warehousing Facilities: In Project's vicinity.
2. Scheduling Responsibility: Preparation of door hardware and keying schedules.
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 3
CAMPUS DOOR ACCESS CONTROL
3. Engineering Responsibility: Preparation of data for electrified door hardware, including Shop Drawings, based on testing and engineering analysis of manufacturer's standard units in assemblies similar to those indicated for this Project.
B. Source Limitations: Obtain each type of door hardware from a single manufacturer.
1. Provide electrified door hardware from same manufacturer as mechanical door hardware, unless otherwise indicated. Manufacturers that perform electrical modifications and that are listed by a testing and inspecting agency acceptable to authorities having jurisdiction are acceptable.
C. Electrified Door Hardware: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction.
D. Means of Egress Doors: Latches do not require more than 15 lbf to release the latch. Locks do not require use of a key, tool, or special knowledge for operation.
E. Accessibility Requirements: Comply with applicable provisions in the DOJ's 2010 ADA Standards for Accessible Design, the ABA Standards of the Federal agency having jurisdiction and ICC A117.1 for door hardware on doors in an accessible route.
1. Provide operating devices that do not require tight grasping, pinching, or twisting of the wrist and that operate with a force of not more than 5 lbf.
2. Comply with the following maximum opening-force requirements:
a. Interior, Non-Fire-Rated Hinged Doors: 5 lbf applied perpendicular to door.
3. Bevel raised thresholds with a slope of not more than 1:2. Provide thresholds not more than 1/2 inch high.
4. Closers: Adjust door and gate closer sweep periods so that, from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
5. Spring Hinges: Adjust door and gate spring hinges so that, from an open position of 70 degrees, the time required to move the door to the closed position is 1.5 seconds minimum.
F. Preinstallation Conference: Conduct conference at Project site.
1. Review and finalize construction schedule and verify availability of materials, Installer's personnel, equipment, and facilities needed to make progress and avoid delays.
2. Inspect and discuss preparatory work performed by other trades.
3. Inspect and discuss electrical roughing-in for electrified door hardware.
4. Review sequence of operation for each type of electrified door hardware.
5. Review required testing, inspecting, and certifying procedures.
1.7 DELIVERY, STORAGE, AND HANDLING
A. Inventory door hardware on receipt and provide secure lock-up for door hardware delivered to Project site.
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 4
CAMPUS DOOR ACCESS CONTROL
B. Tag each item or package separately with identification coordinated with the final door hardware schedule, and include installation instructions, templates, and necessary fasteners with each item or package.
1.8 COORDINATION
A. Installation Templates: Distribute for doors, frames, and other work specified to be factory prepared. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.
B. Security: Coordinate installation of door hardware, keying, and access control with Government's security consultant.
C. Electrical System Roughing-In: Coordinate layout and installation of electrified door hardware with connections to power supplies and building safety and security systems.
D. Existing Openings: Where hardware components are scheduled for application to existing construction or where modifications to existing door hardware are required, field verify existing conditions and coordinate installation of door hardware to suit opening conditions and to provide proper door operation.
1.9 WARRANTY
A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of door hardware that fail in materials or workmanship within specified warranty period.
1. Failures include, but are not limited to, the following:
a. Structural failures including excessive deflection, cracking, or breakage.
b. Faulty operation of doors and door hardware.
c. Deterioration of metals, metal finishes, and other materials beyond normal weathering and use.
2. Warranty Period: Three years from date of Substantial Completion, unless otherwise indicated.
a. Electromagnetic Locks: Five years from date of Substantial Completion.
b. Exit Devices: Two years from date of Substantial Completion.
c. Manual Closers: 10 years from date of Substantial Completion.
1.10 MAINTENANCE SERVICE
A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions for Government's continued adjustment, maintenance, and removal and replacement of door hardware.
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 5
CAMPUS DOOR ACCESS CONTROL
PART 2 - PRODUCTS
2.1 SCHEDULED DOOR HARDWARE
A. Provide door hardware for each door as scheduled on Drawings to comply with requirements in this Section.
1. Door Hardware Sets: Provide quantity, item, size, finish or color indicated.
2. Sequence of Operation: Provide electrified door hardware function, sequence of operation, and interface with other building control systems indicated.
B. Designations: Requirements for design, grade, function, finish, size, and other distinctive qualities of each type of door hardware are indicated in Part 3 "Door Hardware Schedule" Article. Products are identified by descriptive titles corresponding to requirements specified in Part 2.
2.2 HINGES
1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following:
a. Baldwin Hardware Corporation.
b. Bommer Industries, Inc.
c. Cal-Royal Products, Inc.
d. Design Hardware.
e. Hager Companies.
f. Ives; an Allegion brand.
g. Lawrence Hardware Inc.
h. McKinney Products Company; an ASSA ABLOY Group company.
i. PBB, Inc.
j. Stanley Commercial Hardware; a division of Stanley Security Solutions.
B. Antifriction-Bearing Hinges:
1. Mounting: Full mortise (butts).
2. Bearing Material: Manufacturer's standard antifriction bearing
3. Grade: Grade 2 (standard weight).
4. Base and Pin Metal.
5. Pins: Non-rising loose unless otherwise indicated.
a. Outswinging Corridor Doors with Locks: Nonremovable.
6. Tips: Flat button.
C. Electrified Antifriction-Bearing Hinges: Full-mortise mounting.
http://www.specagent.com/Lookup?ulid=118 http://www.specagent.com/Lookup?uid=123456981743 http://www.specagent.com/Lookup?uid=123456981744 http://www.specagent.com/Lookup?uid=123456981745 http://www.specagent.com/Lookup?uid=123456981748 http://www.specagent.com/Lookup?uid=123456981746 http://www.specagent.com/Lookup?uid=123456981739 http://www.specagent.com/Lookup?uid=123456981742 http://www.specagent.com/Lookup?uid=123456981741 http://www.specagent.com/Lookup?uid=123456981747 http://www.specagent.com/Lookup?uid=123456981740
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 6
CAMPUS DOOR ACCESS CONTROL
1. Bearing Material: Manufacturer's standard antifriction bearing
2. Grade 2 (standard weight).
3. Base and Pin Metal:
a. Interior Hinges: Steel with steel pin.
4. Pins: Non-rising loose unless otherwise indicated.
a. Outswinging Corridor Doors with Locks: Nonremovable.
5. Tips: Flat button.
6. Corners: Square.
7. Electric Feature: Concealed electric through wires (5-Wire).
2.3 MECHANICAL LOCKS AND LATCHES
A. Lock Functions: As indicated in door hardware schedule.
B. Lock Throw: Comply with testing requirements for length of bolts required for labeled fire doors, and as follows:
1. Bored Locks: Minimum 1/2-inch latchbolt throw.
C. Lock Backset: 2-3/4 inches, unless otherwise indicated.
D. Lock Trim:
1. Description: Match existing.
2. Levers: Match existing.
E. Strikes: Provide manufacturer's standard strike for each lock bolt or latchbolt complying with requirements indicated for applicable lock or latch and with strike box and curved lip extended to protect frame; finished to match lock or latch.
1. Flat-Lip Strikes: For locks with three-piece antifriction latchbolts, as recommended by manufacturer.
F. Bored Locks: BHMA A156.2; Grade 1; Series 4000.
1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following:
a. Arrow USA; an ASSA ABLOY Group company.
b. Best Access Systems; Stanley Security Solutions, Inc.
c. Cal-Royal Products, Inc.
d. Corbin Russwin, Inc.; an ASSA ABLOY Group company.
e. Design Hardware.
f. Falcon; an Allegion Brand.
http://www.specagent.com/Lookup?ulid=123 http://www.specagent.com/Lookup?uid=123456981784 http://www.specagent.com/Lookup?uid=123456981785 http://www.specagent.com/Lookup?uid=123456981786 http://www.specagent.com/Lookup?uid=123456981776 http://www.specagent.com/Lookup?uid=123456981789 http://www.specagent.com/Lookup?uid=123456981777
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 7
CAMPUS DOOR ACCESS CONTROL
g. K2 Commercial Hardware.
h. Marks USA.
i. Medeco Security Locks; an ASSA ABLOY Group company.
j. PDQ Manufacturing.
k. SARGENT Manufacturing Company; ASSA ABLOY.
l. Schlage; an Allegion brand.
m. Weiser Lock Corp.
n. Yale Security Inc; an ASSA ABLOY Group company.
2.4 ELECTROMECHANICAL LOCKS
A. Electromechanical Locks: BHMA A156.25; Grade 1; motor or solenoid driven; with strike that suits frame.
1. Best Access Systems, 45HW-7-DEU-15-H-626-XXX-RQE with Temperature Control Module, or equal.
2. Type: Mortise deadlocking latchbolt.
2.5 EXIT DEVICES AND AUXILIARY ITEMS
A. Exit Devices and Auxiliary Items: BHMA A156.3.
1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following:
a. Arrow USA; an ASSA ABLOY Group company. (Basis of Design: 80 Series Exit Device – 8900 Mortise Lock Exit Device)
b. Best Access Systems; Stanley Security Solutions, Inc.
c. Cal-Royal Products, Inc.
d. Corbin Russwin, Inc.; an ASSA ABLOY Group company.
e. Design Hardware.
f. Falcon; an Allegion Brand.
g. K2 Commercial Hardware.
h. Marks USA.
i. Medeco Security Locks; an ASSA ABLOY Group company.
j. PDQ Manufacturing.
k. SARGENT Manufacturing Company; ASSA ABLOY.
l. Schlage; an Allegion brand.
m. Weiser Lock Corp.
n. Yale Security Inc; an ASSA ABLOY Group company.
B. Panic Exit Devices: Listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for panic protection, based on testing according to UL 305.
C. Mortise Exit Devices: Grade 1.
1. Type: 3.
ADDENDUM 01
http://www.specagent.com/Lookup?uid=123456981778 http://www.specagent.com/Lookup?uid=123456981788 http://www.specagent.com/Lookup?uid=123456981779 http://www.specagent.com/Lookup?uid=123456981787 http://www.specagent.com/Lookup?uid=123456981780 http://www.specagent.com/Lookup?uid=123456981781 http://www.specagent.com/Lookup?uid=123456981782 http://www.specagent.com/Lookup?uid=123456981783 http://www.specagent.com/Lookup?ulid=123 http://www.specagent.com/Lookup?uid=123456981784 http://www.specagent.com/Lookup?uid=123456981785 http://www.specagent.com/Lookup?uid=123456981786 http://www.specagent.com/Lookup?uid=123456981776 http://www.specagent.com/Lookup?uid=123456981789 http://www.specagent.com/Lookup?uid=123456981777 http://www.specagent.com/Lookup?uid=123456981778 http://www.specagent.com/Lookup?uid=123456981788 http://www.specagent.com/Lookup?uid=123456981779 http://www.specagent.com/Lookup?uid=123456981787 http://www.specagent.com/Lookup?uid=123456981780 http://www.specagent.com/Lookup?uid=123456981781 http://www.specagent.com/Lookup?uid=123456981782 http://www.specagent.com/Lookup?uid=123456981783 sstuart Callout M sstuart Line sstuart Text Box
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 8
CAMPUS DOOR ACCESS CONTROL
2. Actuating Bar: Push pad.
3. Material: Stainless steel.
4. Electrified Features:
a. Electric locking and unlocking.
b. Fail secure electrically unlocked lever, exit device latch is always engaged.
Presenting an active credential unlocks the lever trim and relocks automatically.
c. Delayed egress.
d. Alarm built into exit device.
e. Provide a sign that reads PUSH UNTIL ALARM SOUNDS. DOOR CAN BE
OPENED IN 30 SECONDS. Contractor shall coordinate sign location with COR prior to installation.
2.6 LOCK CYLINDERS
A. Lock Cylinders: Tumbler type, constructed from brass or bronze, stainless steel, or nickel silver.
1. Manufacturer: Stanley-Best Access System – 1C Core, 7Pin.
B. Standard Lock Cylinders: BHMA A156.5; Grade 1; permanent cores that are interchangeable;
face finished to match lockset.
C. Construction Master Keys: Provide cylinders with feature that permits voiding of construction keys without cylinder removal. Provide 10 construction master keys.
D. Construction Cores: Provide construction cores that are replaceable by permanent cores.
Provide 10 construction master keys.
2.7 KEYING
A. Keying System: Factory registered, complying with guidelines in BHMA A156.28, Appendix A. Incorporate decisions made in keying conference.
1. Existing System:
a. Master key or grand master key locks to Government’s existing system.
2.8 SURFACE CLOSERS
A. Surface Closers: BHMA A156.4; rack-and-pinion hydraulic type with adjustable sweep and latch speeds controlled by key-operated valves and forged-steel main arm. Comply with manufacturer's written instructions for size of door closers depending on size of door, exposure to weather, and anticipated frequency of use. Provide factory-sized closers, adjustable to meet field conditions and requirements for opening force.
a. Arrow USA; an ASSA ABLOY Group company.
http://www.specagent.com/Lookup?uid=123456981784 sstuart Line sstuart Callout
15 SECONDS
sstuart Polygon sstuart Callout
ADDENDUM 02
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 9
CAMPUS DOOR ACCESS CONTROL
b. Best Access Systems; Stanley Security Solutions, Inc.
c. Cal-Royal Products, Inc.
d. Corbin Russwin, Inc.; an ASSA ABLOY Group company.
e. Design Hardware.
A. Surface Closer with Cover: Grade 1; Modern type with mechanism enclosed in cover.
1. Mounting: Hinge side (Interior Side).
2. Type: Regular arm.
3. Backcheck: Adjustable, effective between 60 and 85 degrees of door opening.
4. Cover Material: Aluminum.
5. Closing Power Adjustment: At least 50 percent more than minimum tested value.
2.9 CONCEALED DOOR GASKETING
A. Door Gasketing: BHMA A156.22; air leakage not to exceed 0.50 cfm per foot of crack length for gasketing other than for smoke control, as tested according to ASTM E 283; with resilient or flexible seal strips that are easily replaceable and readily available from stocks maintained by manufacturer.
1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following:
a. Hager Companies.
b. M-D Building Products, Inc.
c. National Guard Products, Inc.
d. Pemko Manufacturing Co.
e. Reese Enterprises, Inc.
f. Sealeze.
g. Zero International, Inc.
B. Adhesive-Backed Perimeter Gasketing: Vinyl bulb, Sponge silicone, Silicone, Neoprene bulb or Sponge neoprene gasket material applied to frame rabbet with self-adhesive.
C. Door Sweeps: Neoprene gasket material held in place by flat housing or flange; surface mounted to face of door with screws.
1. Housing or Flange Material: Aluminum.
2.10 THRESHOLDS
A. Thresholds: BHMA A156.21; fabricated to full width of opening indicated.
1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
http://www.specagent.com/Lookup?uid=123456981785 http://www.specagent.com/Lookup?uid=123456981786 http://www.specagent.com/Lookup?uid=123456981776 http://www.specagent.com/Lookup?uid=123456981789 http://www.specagent.com/Lookup?ulid=154 http://www.specagent.com/Lookup?uid=123456981993 http://www.specagent.com/Lookup?uid=123456981994 http://www.specagent.com/Lookup?uid=123456981995 http://www.specagent.com/Lookup?uid=123456981991 http://www.specagent.com/Lookup?uid=123456981996 http://www.specagent.com/Lookup?uid=123456981992 http://www.specagent.com/Lookup?uid=123456981997 http://www.specagent.com/Lookup?ulid=111
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 10
CAMPUS DOOR ACCESS CONTROL
a. Hager Companies.
b. M-D Building Products, Inc.
c. National Guard Products, Inc.
d. Pemko Manufacturing Co.
e. Reese Enterprises, Inc.
f. Rixson Specialty Door Controls; an ASSA ABLOY Group company.
g. Sealeze.
h. Zero International, Inc.
2.11 AUXILIARY DOOR HARDWARE
A. Auxiliary Hardware: BHMA A156.16.
1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following:
a. Baldwin Hardware Corporation.
b. Cal-Royal Products, Inc.
c. Don-Jo Mfg., Inc.
d. Hager Companies.
e. Rockwood Manufacturing Company; an ASSA ABLOY Group company.
f. Stanley Commercial Hardware; a division of Stanley Security Solutions.
g. Trimco.
B. Silencers for Metal Door Frames: Grade 1; neoprene or rubber; minimum diameter 1/2 inch;
fabricated for drilled-in application to frame.
2.12 AUXILIARY ELECTRIFIED DOOR HARDWARE
A. Auxiliary Electrified Door Hardware:
1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following:
a. DynaLock Corp.
b. GE Security, Inc.
c. SARGENT Manufacturing Company; ASSA ABLOY.
d. Schlage; an Allegion brand.
e. Securitron Magnalock Corporation; an ASSA ABLOY Group company.
f. Security Door Controls.
B. Boxed Power Supplies: Modular unit in NEMA ICS 6, Type 1 enclosure; filtered and regulated;
voltage rating and type matching requirements of door hardware served; listed and labeled for use with fire alarm systems.
http://www.specagent.com/Lookup?uid=123457091987 http://www.specagent.com/Lookup?uid=123457091988 http://www.specagent.com/Lookup?uid=123457091989 http://www.specagent.com/Lookup?uid=123457091990 http://www.specagent.com/Lookup?uid=123457091991 http://www.specagent.com/Lookup?uid=123457091992 http://www.specagent.com/Lookup?uid=123457091993 http://www.specagent.com/Lookup?uid=123457091994 http://www.specagent.com/Lookup?ulid=160 http://www.specagent.com/Lookup?uid=123456982038 http://www.specagent.com/Lookup?uid=123456982039 http://www.specagent.com/Lookup?uid=123456982040 http://www.specagent.com/Lookup?uid=123456982041 http://www.specagent.com/Lookup?uid=123456982037 http://www.specagent.com/Lookup?uid=123456982036 http://www.specagent.com/Lookup?uid=123456982042 http://www.specagent.com/Lookup?ulid=161 http://www.specagent.com/Lookup?uid=123456982048 http://www.specagent.com/Lookup?uid=123456982047 http://www.specagent.com/Lookup?uid=123456982043 http://www.specagent.com/Lookup?uid=123456982044 http://www.specagent.com/Lookup?uid=123456982045 http://www.specagent.com/Lookup?uid=123456982046
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 11
CAMPUS DOOR ACCESS CONTROL
C. Door and Frame Transfer Devices: Steel housing for mortise in hinge stile of door, with flexible tube for wiring bundle; accommodating doors that swing open to 120 degrees.
2.13 FABRICATION
A. Manufacturer's Nameplate: Do not provide products that have manufacturer's name or trade name displayed in a visible location except in conjunction with required fire-rated labels and as otherwise approved by Contracting Officer.
1. Manufacturer's identification is permitted on rim of lock cylinders only.
B. Base Metals: Produce door hardware units of base metal indicated, fabricated by forming method indicated, using manufacturer's standard metal alloy, composition, temper, and hardness. Furnish metals of a quality equal to or greater than that of specified door hardware units and BHMA A156.18.
C. Fasteners: Provide door hardware manufactured to comply with published templates prepared for machine, wood, and sheet metal screws. Provide screws that comply with commercially recognized industry standards for application intended, except aluminum fasteners are not permitted. Provide Phillips flat-head screws with finished heads to match surface of door hardware, unless otherwise indicated.
1. Spacers or Sex Bolts: For through bolting of hollow-metal doors.
2. Gasketing Fasteners: Provide noncorrosive fasteners for exterior applications and elsewhere as indicated.
2.14 FINISHES
A. Provide finishes complying with BHMA A156.18 as indicated in door hardware schedule.
B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.
C. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are acceptable if they are within one-half of the range of approved Samples. Noticeable variations in the same piece are not acceptable. Variations in appearance of other components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire-rated door assembly construction, wall and floor construction, and other conditions affecting performance.
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 12
CAMPUS DOOR ACCESS CONTROL
B. Examine roughing-in for electrical power systems to verify actual locations of wiring connections before electrified door hardware installation.
C. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Steel Doors and Frames: For surface applied door hardware, drill and tap doors and frames according to ANSI/SDI A250.6.
3.3 INSTALLATION
A. Mounting Heights: Mount door hardware units at heights to comply with the following unless otherwise indicated or required to comply with governing regulations.
1. Standard Steel Doors and Frames: ANSI/SDI A250.8.
B. Install each door hardware item to comply with manufacturer's written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, coordinate removal, storage, and reinstallation of surface protective trim units with finishing work. Do not install surface-mounted items until finishes have been completed on substrates involved.
1. Set units level, plumb, and true to line and location. Adjust and reinforce attachment substrates as necessary for proper installation and operation.
2. Drill and countersink units that are not factory prepared for anchorage fasteners. Space fasteners and anchors according to industry standards.
C. Hinges: Install types and in quantities indicated in door hardware schedule but not fewer than the number recommended by manufacturer for application indicated or one hinge for every 30 inches of door height, whichever is more stringent, unless other equivalent means of support for door, such as spring hinges or pivots, are provided.
D. Lock Cylinders: Install construction cores to secure building and areas during construction period.
1. Government to provide permanent cores for installation.
E. Boxed Power Supplies: Locate power supplies as indicated or, if not indicated, above accessible ceilings. Verify location with Contracting Officer Representative.
1. Configuration: Provide least number of power supplies required to adequately serve doors with electrified door hardware.
F. Perimeter Gasketing: Apply to head and jamb, forming seal between door and frame.
G. Door Bottoms: Apply to bottom of door, forming seal with threshold when door is closed.
NIFC 215 GREAT BASIN CACHE WAREHOUSE 087111 - 13
CAMPUS DOOR ACCESS CONTROL
3.4 ADJUSTING
A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.
1. Door Closers: Adjust sweep period to comply with accessibility requirements and requirements of authorities having jurisdiction.
3.5 CLEANING AND PROTECTION
A. Clean adjacent surfaces soiled by door hardware installation.
B. Clean operating items as necessary to restore proper function and finish.
C. Provide final protection and maintain conditions that ensure that door hardware is without damage or deterioration at time of Substantial Completion.
3.6 DEMONSTRATION
A. Engage a factory-authorized service representative to train Government's maintenance personnel to adjust, operate, and maintain door hardware and door hardware finishes. Refer to Section 018200 "Demonstration and Training."
END OF SECTION 087111
| PART 1 - GENERAL |
| 1.1 RELATED DOCUMENTS |
| A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. |
| 1.2 SUMMARY |
| A. Section includes: |
| B. Related Requirements: |
| 1.3 ACTION SUBMITTALS |
| A. Product Data: For each type of product indicated. Include construction and installation details, material descriptions, dimensions of individual components and profiles, and finishes. |
| B. Shop Drawings: Details of electrified door hardware, indicating the following: |
| C. Other Action Submittals: |
| 1.4 INFORMATIONAL SUBMITTALS |
| A. Qualification Data: For Installer. |
| B. Product Certificates: For electrified door hardware, from the manufacturer. |
| C. Warranty: Special warranty specified in this Section. |
| 1.5 CLOSEOUT SUBMITTALS |
| A. Maintenance Data: For each type of door hardware to include in maintenance manuals. Include final hardware schedule. |
| 1.6 QUALITY ASSURANCE |
| A. Installer Qualifications: Supplier of products and an employer of workers trained and approved by product manufacturers and an Architectural Hardware Consultant who is available during the course of the Work to consult with Contractor and Government about door hardware and keying. |
| B. Source Limitations: Obtain each type of door hardware from a single manufacturer. |
| C. Electrified Door Hardware: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction. |
| D. Means of Egress Doors: Latches do not require more than 15 lbf (67 N) to release the latch. Locks do not require use of a key, tool, or special knowledge for operation. |
| E. Accessibility Requirements: Comply with applicable provisions in the DOJ's 2010 ADA Standards for Accessible Design, the ABA Standards of the Federal agency having jurisdiction and ICC A117.1 for door hardware on doors in an accessible route. |
| F. Preinstallation Conference: Conduct conference at Project site. |
| 1.7 DELIVERY, STORAGE, AND HANDLING |
| A. Inventory door hardware on receipt and provide secure lock-up for door hardware delivered to Project site. |
| B. Tag each item or package separately with identification coordinated with the final door hardware schedule, and include installation instructions, templates, and necessary fasteners with each item or package. |
| 1.8 COORDINATION |
| A. Installation Templates: Distribute for doors, frames, and other work specified to be factory prepared. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements. |
| B. Security: Coordinate installation of door hardware, keying, and access control with Government's security consultant. |
| C. Electrical System Roughing-In: Coordinate layout and installation of electrified door hardware with connections to power supplies and building safety and security systems. |
| D. Existing Openings: Where hardware components are scheduled for application to existing construction or where modifications to existing door hardware are required, field verify existing conditions and coordinate installation of door hardware to suit opening conditions and to provide proper door operation. |
| 1.9 WARRANTY |
| A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of door hardware that fail in materials or workmanship within specified warranty period. |
| 1.10 MAINTENANCE SERVICE |
| A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions for Government's continued adjustment, maintenance, and removal and replacement of door hardware. |
| PART 2 - PRODUCTS |
| 2.1 SCHEDULED DOOR HARDWARE |
| A. Provide door hardware for each door as scheduled on Drawings to comply with requirements in this Section. |
| B. Designations: Requirements for design, grade, function, finish, size, and other distinctive qualities of each type of door hardware are indicated in Part 3 "Door Hardware Schedule" Article. Products are identified by descriptive titles corresponding to requirements specified in Part 2. |
| 2.2 HINGES |
| B. Antifriction-Bearing Hinges: |
| C. Electrified Antifriction-Bearing Hinges: Full-mortise mounting. |
| 2.3 MECHANICAL LOCKS AND LATCHES |
| A. Lock Functions: As indicated in door hardware schedule. |
| B. Lock Throw: Comply with testing requirements for length of bolts required for labeled fire doors, and as follows: |
| C. Lock Backset: 2-3/4 inches (70 mm), unless otherwise indicated. |
| D. Lock Trim: |
| E. Strikes: Provide manufacturer's standard strike for each lock bolt or latchbolt complying with requirements indicated for applicable lock or latch and with strike box and curved lip extended to protect frame; finished to match lock or latch. |
| F. Bored Locks: BHMA A156.2; Grade 1; Series 4000. |
| 2.4 ELECTROMECHANICAL LOCKS |
| A. Electromechanical Locks: BHMA A156.25; Grade 1; motor or solenoid driven; with strike that suits frame. |
| 2.5 EXIT DEVICES AND AUXILIARY ITEMS |
| A. Exit Devices and Auxiliary Items: BHMA A156.3. |
| B. Panic Exit Devices: Listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for panic protection, based on testing according to UL 305. |
| C. Mortise Exit Devices: Grade 1. |
| 2.6 LOCK CYLINDERS |
| A. Lock Cylinders: Tumbler type, constructed from brass or bronze, stainless steel, or nickel silver. |
| B. Standard Lock Cylinders: BHMA A156.5; Grade 1; permanent cores that are interchangeable; face finished to match lockset. |
| C. Construction Master Keys: Provide cylinders with feature that permits voiding of construction keys without cylinder removal. Provide 10 construction master keys. |
| D. Construction Cores: Provide construction cores that are replaceable by permanent cores. Provide 10 construction master keys. |
| 2.7 KEYING |
| A. Keying System: Factory registered, complying with guidelines in BHMA A156.28, Appendix A. Incorporate decisions made in keying conference. |
| 2.8 SURFACE CLOSERS |
| A. Surface Closers: BHMA A156.4; rack-and-pinion hydraulic type with adjustable sweep and latch speeds controlled by key-operated valves and forged-steel main arm. Comply with manufacturer's written instructions for size of door closers depending on size of door, exposure to weather, and anticipated frequency of use. Provide factory-sized closers, adjustable to meet field conditions and requirements for opening force. |
| A. Surface Closer with Cover: Grade 1; Modern type with mechanism enclosed in cover. |
| 2.9 CONCEALED DOOR GASKETING |
| A. Door Gasketing: BHMA A156.22; air leakage not to exceed 0.50 cfm per foot (0.000774 cu. m/s per m) of crack length for gasketing other than for smoke control, as tested according to ASTM E 283; with resilient or flexible seal strips that are easily replaceable and readily available from stocks maintained by manufacturer. |
| B. Adhesive-Backed Perimeter Gasketing: Vinyl bulb, Sponge silicone, Silicone, Neoprene bulb or Sponge neoprene gasket material applied to frame rabbet with self-adhesive. |
| C. Door Sweeps: Neoprene gasket material held in place by flat housing or flange; surface mounted to face of door with screws. |
| 2.10 THRESHOLDS |
| A. Thresholds: BHMA A156.21; fabricated to full width of opening indicated. |
| 2.11 AUXILIARY DOOR HARDWARE |
| A. Auxiliary Hardware: BHMA A156.16. |
| B. Silencers for Metal Door Frames: Grade 1; neoprene or rubber; minimum diameter 1/2 inch (13 mm); fabricated for drilled-in application to frame. |
| 2.12 AUXILIARY ELECTRIFIED DOOR HARDWARE |
| A. Auxiliary Electrified Door Hardware: |
| B. Boxed Power Supplies: Modular unit in NEMA ICS 6, Type 1 enclosure; filtered and regulated; voltage rating and type matching requirements of door hardware served; listed and labeled for use with fire alarm systems. |
| C. Door and Frame Transfer Devices: Steel housing for mortise in hinge stile of door, with flexible tube for wiring bundle; accommodating doors that swing open to 120 degrees. |
| 2.13 FABRICATION |
| A. Manufacturer's Nameplate: Do not provide products that have manufacturer's name or trade name displayed in a visible location except in conjunction with required fire-rated labels and as otherwise approved by Contracting Officer. |
| B. Base Metals: Produce door hardware units of base metal indicated, fabricated by forming method indicated, using manufacturer's standard metal alloy, composition, temper, and hardness. Furnish metals of a quality equal to or greater than that of specified door hardware units and BHMA A156.18. |
| C. Fasteners: Provide door hardware manufactured to comply with published templates prepared for machine, wood, and sheet metal screws. Provide screws that comply with commercially recognized industry standards for application intended, except aluminum fasteners are not permitted. Provide Phillips flat-head screws with finished heads to match surface of door hardware, unless otherwise indicated. |
| 2.14 FINISHES |
| A. Provide finishes complying with BHMA A156.18 as indicated in door hardware schedule. |
| B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping. |
| C. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are acceptable if they are within one-half of the range of approved Samples. Noticeable variations in the same piece are not acceptable. Variations in appearance of other components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast. |
| PART 3 - EXECUTION |
| 3.1 EXAMINATION |
| A. Examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire-rated door assembly construction, wall and floor construction, and other conditions affecting performance. |
| B. Examine roughing-in for electrical power systems to verify actual locations of wiring connections before electrified door hardware installation. |
| C. Proceed with installation only after unsatisfactory conditions have been corrected. |
| 3.2 PREPARATION |
| A. Steel Doors and Frames: For surface applied door hardware, drill and tap doors and frames according to ANSI/SDI A250.6. |
| 3.3 INSTALLATION |
| A. Mounting Heights: Mount door hardware units at heights to comply with the following unless otherwise indicated or required to comply with governing regulations. |
| B. Install each door hardware item to comply with manufacturer's written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, coordinate removal, storage, and reinstallation of surface protective trim units with finishing work. Do not install surface-mounted items until finishes have been completed on substrates involved. |
| C. Hinges: Install types and in quantities indicated in door hardware schedule but not fewer than the number recommended by manufacturer for application indicated or one hinge for every 30 inches (750 mm) of door height, whichever is more stringent, unless other equivalent means of support for door, such as spring hinges or pivots, are provided. |
| D. Lock Cylinders: Install construction cores to secure building and areas during construction period. |
| E. Boxed Power Supplies: Locate power supplies as indicated or, if not indicated, above accessible ceilings. Verify location with Contracting Officer Representative. |
| F. Perimeter Gasketing: Apply to head and jamb, forming seal between door and frame. |
| G. Door Bottoms: Apply to bottom of door, forming seal with threshold when door is closed. |
| 3.4 ADJUSTING |
| A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements. |
| 3.5 CLEANING AND PROTECTION |
| A. Clean adjacent surfaces soiled by door hardware installation. |
| B. Clean operating items as necessary to restore proper function and finish. |
| C. Provide final protection and maintain conditions that ensure that door hardware is without damage or deterioration at time of Substantial Completion. |
| 3.6 DEMONSTRATION |
| A. Engage a factory-authorized service representative to train Government's maintenance personnel to adjust, operate, and maintain door hardware and door hardware finishes. Refer to Section 018200 "Demonstration and Training." |