Exhibit_A__CCTV_Plan_R_0001.pdf
PDF 4 MB Posted
- Attached to
- UMESC CCTV - INSPECTION, PM & UPGRADES Federal contract opportunity
- Solicitation number
- 140G0223Q0114
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140G0223Q0114_Amd_0002.pdf | ||
| Sol_140G0223Q0114_Amd_0001.pdf | ||
| Capture2_0001.PNG | PNG image | |
| Sol_140G0223Q0114.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
l;\fll HOUSE 3
SURGE
POND
REARING
PONDS
VEHICLE
ENTRANCE
f
EAST PARKING
LOT
BtllLDiNG G HEATED
STORAGE
SOUTH
PARKING
LOT
CCV SITE PLAN
SCALE: NTS
NEWCAM#1NEWCAM#1
NEWCAM#1NEWCAM#2
mgoede Highlight mgoede Highlight
U P
FISH HOLDING HOUSE
ELEV
UP
UP
UP
UP
A
B
C
CORE
STOR.
MENWOMEN
JAN.
STOR.
PHYS.
BEHAV.
WOMEN MEN
CORE
WEIGH
UP
JAR
WASH
4a
WATER
WATER
CHEM.
4b
FLOWING
ASSAY LAB
EFFICACY
LAB
39A
39L
EFFICACY
LAB
3a
3b
INVERT.
WET LAB
TOXIC
PREP
1a OFFICE
OFFICE
OFFICE
OFFICE
PHYS.
PREP
12b
OFFICE
FLOWING
ASSAY LAB
PHYS.
WET LAB
INVERT.
WET LAB
LAB
16a
INVERT.
PREP
BALN.
ROOM
17a
TOXIC
PREP
BAL.
15b
CHEM.
STOR.
15a
EQUIP.
34a
STATIC
ASSAY LAB
RECEIVING
BOILER
ROOM
GC2 GC1
MECH.
EQUIP.
LIBRARY
JAN.
CONF.
RM
GEN.
ELEV.
EQUIP.
ELEC.
OFFICE
INVERT
LAB
21a
INVERT
LAB
21b
OFFICE
21c
DIAG
LAB
21d
PREP &
STOR.
21e
E
P A N E L S
E
P A N E L S
E L E C
P A N E L S
GC3
PUMP
ROOM
E
P A N E L S
E
P A N E L S
DUCT
MECH
EQUIP
AHU
CONDENSING
UNIT
BC-F1-5X
BC-F1-4
BA-F1-1
BA-F1-2
BB-F1-1
BB-F1-2
BC-F1-2
BC-F1-1
BC-F1-3
BC-F1-7X
BC-F1-6X
SCALE:
T-101
LAB/OFFICE LOWER LEVEL CCV PLAN
3/32" = 1'
1. ALL LOCATIONS SHOWN ARE NOT EXACT
LOCATIONS. ACTUAL MOUNTING HEIGHTS
AND LOCATIONS NEED TO BE FIELD VERIFIED
BEFORE INSTALLATION.
2. ALL EXTERIOR DEVICES WILL REQUIRE AN
EXTERIOR GRADE ENHANCED CAT6 CABLE.
3. ALL EXTERIOR PENETRATIONS ARE TO BE
SEALED WITH CLEAR WEATHERPROOF
SILICON CAULK.
4. TERMINATE EXTERIOR ENHANCED CAT6
CABLE ON DITEK SURGE PROTECTORS.
ROUTE 14AWG GROUND CABLE TO TMGB OR
TGB.
5. ALL CABLES TO BE SUPPORTED BY J-HOOKS
OR EQUIVALENT APPROVED CABLE SUPPORT
SYSTEM.
CONDUIT SLEEVE BETWEEN FLOORS.
CABLES ROUTING BETWEEN OPEN STRUCTURE
BETWEEN FLOORS.
KEYED NOTES:
scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
LAB/OFFICE LOWER
LEVEL CCV PLAN
T-101
SCALE: 3/32" = 1'
1 AS-BUILT DRAWINGS 11/19/2020
GENERAL NOTES:
BC-F1-7X
NEWCAM#3
mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Callout
ELEV
RECEPTION/
EXHIBIT
DN
A
B
C
CORE
CORE
DN
DN
DN
D N
VEST.
SECRETARY
DN
OFFICE
ADMIN. MACHINE
WORK AREA
MECH
EQUIP
AHU 1
MECH
EQUIP
MECH
EQUIP
MECH
EQUIP
AHU 2
DUCT DUCT
DUCTDUCT
MECH
EQUIP
AHU
MECH
EQUIP
AHU
E
P A N E L S
ROOF
HATCH
BA-F2-1
BA-F2-2
BB-F2-2
BB-F2-1
BC-F2-2
BC-F2-3
BC-F2-7
BC-F2-6
BC-F2-1
BC-F2-5
IT ROOM
B-219
IT ROOM
C-212
P
IT ROOM
A-101
BA-F2-3X
BC-F2-8x
BB-F2-3X
BC-F2-4x
BC-F2-9x
SCALE:
T-102
LAB/OFFICE UPPER LEVEL CCV PLAN
3/32" = 1'
1. ALL LOCATIONS SHOWN ARE NOT EXACT
LOCATIONS. ACTUAL MOUNTING HEIGHTS
AND LOCATIONS NEED TO BE FIELD VERIFIED
BEFORE INSTALLATION.
2. ALL EXTERIOR DEVICES WILL REQUIRE AN
EXTERIOR GRADE ENHANCED CAT6 CABLE.
3. ALL EXTERIOR PENETRATIONS ARE TO BE
SEALED WITH CLEAR WEATHERPROOF
SILICON CAULK.
4. TERMINATE EXTERIOR ENHANCED CAT6
CABLE ON DITEK SURGE PROTECTORS.
ROUTE 14AWG GROUND CABLE TO TMGB OR
TGB.
5. ALL CABLES TO BE SUPPORTED BY J-HOOKS
OR EQUIVALENT APPROVED CABLE SUPPORT
SYSTEM.
EXISTING FIBER PATHWAY BETWEEN IT ROOM
C-212 AND B-219.
EXISTING FIBER PATHWAY BETWEEN IT ROOM
C-212 AND D-350b.
EXISTING FIBER PATHWAY BETWEEN IT ROOM
C-212 AND G-116.
EXISTING FIBER PATHWAY BETWEEN IT ROOM
C-212 AND POND STORAGE.
CCV EQUIPMENT LOCATION.
CONDUIT SLEEVE BETWEEN FLOORS.
NEW ENHANCED CAT6 BACKBONE CABLE
BETWEEN IT ROOM A-101 AND IT ROOM B-219.
CABLES ROUTING BETWEEN OPEN STRUCTURE
BETWEEN FLOORS.
EXISTING FIBER PATHWAY BETWEEN IT ROOM
C-212 AND WELL HOUSE 2.
FIBER PATCH CABLE BETWEEN IT ROOM C-214
AND IT ROOM C-212.
EXISTING FIBER PATHWAY BETWEEN IT ROOM
C-212 AND TOX BUILDING.
KEYED NOTES:
scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
LAB/OFFICE UPPER
LEVEL CCV PLAN
T-102
SCALE: 3/32" = 1'
1 AS-BUILT DRAWINGS 11/19/2020
GENERAL NOTES:
T-401
T-401
T-401 5
11 NEWCAM#4
mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight
BD-F1-3
BD-F1-2
BD-F1-1
SCALE:
T-103
BUILDING D LOWER LEVEL CCV PLAN
3/32" = 1'
1. ALL LOCATIONS SHOWN ARE NOT EXACT
LOCATIONS. ACTUAL MOUNTING HEIGHTS
AND LOCATIONS NEED TO BE FIELD VERIFIED
BEFORE INSTALLATION.
2. ALL EXTERIOR DEVICES WILL REQUIRE AN
EXTERIOR GRADE ENHANCED CAT6 CABLE.
3. ALL EXTERIOR PENETRATIONS ARE TO BE
SEALED WITH CLEAR WEATHERPROOF
SILICON CAULK.
4. TERMINATE EXTERIOR ENHANCED CAT6
CABLE ON DITEK SURGE PROTECTORS.
ROUTE 14AWG GROUND CABLE TO TMGB OR
TGB.
5. ALL CABLES TO BE SUPPORTED BY J-HOOKS
OR EQUIVALENT APPROVED CABLE SUPPORT
SYSTEM.
scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
BUILDING D LOWER
LEVEL CCV PLAN
T-103
SCALE: 3/32" = 1'
1 AS-BUILT DRAWINGS 11/19/2020
GENERAL NOTES:
CONDUIT SLEEVE BETWEEN FLOORS.1
KEYED NOTES:
NEWCAM#5
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FE
AutoCAD SHX Text
FEC
mgoede Highlight mgoede Highlight mgoede Highlight
BD-F2-6X
BD-F2-1
BD-F2-5
BD-F2-4
BD-F2-3
BD-F2-2
BD-F2-6
IT ROOM
D-350b
1. ALL LOCATIONS SHOWN ARE NOT EXACT
LOCATIONS. ACTUAL MOUNTING HEIGHTS
AND LOCATIONS NEED TO BE FIELD VERIFIED
BEFORE INSTALLATION.
2. ALL EXTERIOR DEVICES WILL REQUIRE AN
EXTERIOR GRADE ENHANCED CAT6 CABLE.
3. ALL EXTERIOR PENETRATIONS ARE TO BE
SEALED WITH CLEAR WEATHERPROOF
SILICON CAULK.
4. TERMINATE EXTERIOR ENHANCED CAT6
CABLE ON DITEK SURGE PROTECTORS.
ROUTE 14AWG GROUND CABLE TO TMGB OR
TGB.
5. ALL CABLES TO BE SUPPORTED BY J-HOOKS
OR EQUIVALENT APPROVED CABLE SUPPORT
SYSTEM.
GENERAL NOTES:
SCALE:
T-104
BUILDING D UPPER LEVEL CCV PLAN
3/32" = 1'
EXISTING FIBER PATHWAY BETWEEN IT ROOM
C-212 AND B-219.
CCV EQUIPMENT LOCATION.
CONDUIT SLEEVE BETWEEN FLOORS.
KEYED NOTES:
scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
BUILDING D UPPER
LEVEL CCV PLAN
T-104
SCALE: 3/32" = 1'
1 AS-BUILT DRAWINGS 11/19/2020
T-401
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text F.E.
AutoCAD SHX Text
EXG.
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FEC
mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight
SOUTH CHEMICAL
BUNKER
SOUTH CHEMICAL
BUNKER
NORTH CHEMICAL
BUNKER
NORTH CHEMICAL
BUNKER
OFFICEGIS
STORAGE
LOCKER
OFFICES
SPRINKLER
RISER ROOM
BREAK
ROOM STORAGE
COMMONS
CLOSET
OFFICE OFFICE OFFICE OFFICE
CONFERENCE HALL
OFFICE OFFICE OFFICE
OFFICEOFFICEOFFICE
BH-F1-1x
SCALE:
T-105
HEATED STORAGE CCV PLAN
1/8" = 1'
SCALE:
T-105
BUILDING G / CHEMICAL BUNKER CCV PLAN
1/8" = 1'
1. ALL LOCATIONS SHOWN ARE NOT EXACT
LOCATIONS. ACTUAL MOUNTING HEIGHTS
AND LOCATIONS NEED TO BE FIELD VERIFIED
BEFORE INSTALLATION.
2. ALL EXTERIOR DEVICES WILL REQUIRE AN
EXTERIOR GRADE ENHANCED CAT6 CABLE.
3. ALL EXTERIOR PENETRATIONS ARE TO BE
SEALED WITH CLEAR WEATHERPROOF
SILICON CAULK.
4. TERMINATE EXTERIOR ENHANCED CAT6
CABLE ON DITEK SURGE PROTECTORS.
ROUTE 14AWG GROUND CABLE TO TMGB OR
TGB.
5. ALL CABLES TO BE SUPPORTED BY J-HOOKS
OR EQUIVALENT APPROVED CABLE SUPPORT
SYSTEM.
GENERAL NOTES:
CCV EQUIPMENT LOCATION.
EXISTING CONDUIT SLEEVE BETWEEN HEATED
STORAGE AND IT ROOM G-116.
KEYED NOTES:
scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
HEATED STORAGE AND
BLDG G CCV PLAN
T-105
SCALE: 1/8" = 1'
1 AS-BUILT DRAWINGS 11/19/2020
T-401
NEWCAM#6
AutoCAD SHX Text G-5
AutoCAD SHX Text G-1
AutoCAD SHX Text G-6
AutoCAD SHX Text G-4
AutoCAD SHX Text G-2
AutoCAD SHX Text G-7
AutoCAD SHX Text G-24
AutoCAD SHX Text G-23
AutoCAD SHX Text G-22
AutoCAD SHX Text G-21
AutoCAD SHX Text G-8
AutoCAD SHX Text G-9
AutoCAD SHX Text G-10
AutoCAD SHX Text G-11
AutoCAD SHX Text G-20
AutoCAD SHX Text G-19
AutoCAD SHX Text G-12
AutoCAD SHX Text G-13
AutoCAD SHX Text G-14
AutoCAD SHX Text G-16
AutoCAD SHX Text G-17
AutoCAD SHX Text G-18 mgoede Highlight
WH2-F1-2x
WH2-F1-2x
SCALE:
T-106
WELL HOUSE 2 CCV PLAN
3/32" = 1'
1. ALL LOCATIONS SHOWN ARE NOT EXACT
LOCATIONS. ACTUAL MOUNTING HEIGHTS
AND LOCATIONS NEED TO BE FIELD VERIFIED
BEFORE INSTALLATION.
2. ALL EXTERIOR DEVICES WILL REQUIRE AN
EXTERIOR GRADE ENHANCED CAT6 CABLE.
3. ALL EXTERIOR PENETRATIONS ARE TO BE
SEALED WITH CLEAR WEATHERPROOF
SILICON CAULK.
4. TERMINATE EXTERIOR ENHANCED CAT6
CABLE ON DITEK SURGE PROTECTORS.
ROUTE 14AWG GROUND CABLE TO TMGB OR
TGB.
5. ALL CABLES TO BE SUPPORTED BY J-HOOKS
OR EQUIVALENT APPROVED CABLE SUPPORT
SYSTEM.
GENERAL NOTES:
CCV EQUIPMENT LOCATION.
EXISTING UNDERGROUND CONDUIT BETWEEN
BUILDINGS. ROUTE (2) CAT6 CABLE TO
CAMERAS.
KEYED NOTES:
scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
WELL HOUSE 2
CCV PLAN
T-106
SCALE: 3/32" = 1'
1 AS-BUILT DRAWINGS 11/19/2020
T-401 mgoede Highlight
PS-F1-1x PS-F1-2x
PS-F1-3x
TB-F1-2x
TB-F1-1x
SCALE:
T-107
POND STORAGE CCV PLAN
1/8" = 1'
1. ALL LOCATIONS SHOWN ARE NOT EXACT
LOCATIONS. ACTUAL MOUNTING HEIGHTS
AND LOCATIONS NEED TO BE FIELD VERIFIED
BEFORE INSTALLATION.
2. ALL EXTERIOR DEVICES WILL REQUIRE AN
EXTERIOR GRADE ENHANCED CAT6 CABLE.
3. ALL EXTERIOR PENETRATIONS ARE TO BE
SEALED WITH CLEAR WEATHERPROOF
SILICON CAULK.
4. TERMINATE EXTERIOR ENHANCED CAT6
CABLE ON DITEK SURGE PROTECTORS.
ROUTE 14AWG GROUND CABLE TO TMGB OR
TGB.
5. ALL CABLES TO BE SUPPORTED BY J-HOOKS
OR EQUIVALENT APPROVED CABLE SUPPORT
SYSTEM.
GENERAL NOTES:
CCV EQUIPMENT LOCATION.1
KEYED NOTES:
scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
POND STORAGE AND
TOX. BLDG CCV PLAN
T-107
SCALE: 1/8" = 1'
1 AS-BUILT DRAWINGS 11/19/2020
T-401
T-401
SCALE:
T-107
TOX. BUILDING CCV PLAN
1/8" = 1' mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight
VE-F1-2x
VE-F1-1x
P
SCALE:
T-108
VEHICLE ENTRANCE POLE DETAIL
1:10
1. ALL LOCATIONS SHOWN ARE NOT EXACT
LOCATIONS. ACTUAL MOUNTING HEIGHTS
AND LOCATIONS NEED TO BE FIELD VERIFIED
BEFORE INSTALLATION.
2. ALL EXTERIOR DEVICES WILL REQUIRE AN
EXTERIOR GRADE ENHANCED CAT6 CABLE.
3. ALL EXTERIOR PENETRATIONS ARE TO BE
SEALED WITH CLEAR WEATHERPROOF
SILICON CAULK.
4. TERMINATE EXTERIOR ENHANCED CAT6
CABLE ON DITEK SURGE PROTECTORS.
ROUTE 14AWG GROUND CABLE TO
ELECTRICAL GROUND.
5. USE EXISTING CABLE AND EQUIPMENT
WHERE APPLICABLE. ONLY USE CABLE THAT
PASSES TIA/EIA CABLE TEST.
scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
VEHICLE ENTRANCE
CCV POLE PLAN
T-108
SCALE: AS NOTED
1 AS-BUILT DRAWINGS 11/19/2020
GENERAL NOTES:
T-108
EXISTING POINT TO POINT BACK TO BUILDING B
NEW PELCO IBP531-1ER
TEST AND USE EXISTING CABLE
IF POSSIBLE
EXISTING POLE MOUNTED
WEATHERPROOF ENCLOSURE
USE EXISTING EQUIPMENT
WHERE APPLICABLE
EXISTING POLE
EXISTING CONCRETE PEDESTAL
FINISHED GRADE
NEW PELCO IBP531-1ER
TEST AND USE EXISTING CABLE
IF POSSIBLE
CAT6 CABLE ROUTED
THROUGH POLE TO ENCLOSURE
USE EXISTING POWER
SUPPLIED BY OTHERS
SCALE:
T-108
VEHICLE ENTRANCE CCV PLAN
3/32" = 1'
(1) ENHANCED CAT6 CABLE ROUTED ABOVE
CEILING TO NEAREST IT CLOSET
J-HOOK CABLE SUPPORT SYSTEM
DROP CEILING
EXTERIOR CAT6
10' ENHANCED
CAT6 SERVICE LOOP
FINISHED FLOOR
CONDUIT SLEEVE W/ BUSHING
BUILDING B
EXISTING STRUCTURE
EXISTING POINT TO POINT
UNIT TO VEHICLE ENTRANCE
SCALE:
T-108
VEHICLE ENTRANCE POINT TO POINT DETAIL
1:10 mgoede Highlight scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
CCV EQUIPMENT
SCHEDULE
T-201
SCALE: NTS
1 AS-BUILT DRAWINGS 11/19/2020
SCALE:
T-201
CCV EQUIPMENT SCHEDULE
NTS
Device Name Building IP Address MAC Address Subnet Mask Gateway Type Model Firmware IDF / MDF Switch # Port # Username Password
A SWITCH BLDG A 192.168.10.3 00:72:78:89:2F:0A 255.255.255.0 192.168.10.1 CISCO SF250-24P A-101 admin umesc_608
BA-F1-1 BLDG A 192.168.10.20 00:04:7D:41:75:BD 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 A-101 A 1 admin umesc608
BA-F1-2 BLDG A 192.168.10.21 00:04:7D:41:52:E7 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 A-101 A 2 admin umesc608
BA-F2-1 BLDG A 192.168.10.22 00:04:7D:41:75:F3 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 A-101 A 3 admin umesc608
BA-F2-2 BLDG A 192.168.10.23 00:04:7D:41:75:BF 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 A-101 A 4 admin umesc608
BA-F2-3x BLDG A 192.168.10.24 00:04:7D:41:70:DD 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 A-101 A 5 admin umesc608
B SWITCH BLDG B 192.168.10.4 00:72:78:89:2E:3F 255.255.255.0 192.168.10.1 CISCO SF250-24P 2.32 A-101 admin umesc_608
BB-F1-1 BLDG B 192.168.10.25 00:04:7D:41:52:E3 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 B-219 B 1 admin umesc608
BB-F1-2 BLDG B 192.168.10.26 00:04:7D:41:75:FD 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 B-219 B 2 admin umesc608
BB-F2-1 BLDG B 192.168.10.27 00:04:7D:41:75:F9 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 B-219 B 3 admin umesc608
BB-F2-2 BLDG B 192.168.10.28 00:04:7D:41:75:C9 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 B-219 B 4 admin umesc608
BB-F2-3x BLDG B 192.168.10.29 00:04:7D:41:71:A2 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 B-219 B 5 admin umesc608
C SWITCH BLDG C 192.168.10.5 00:72:78:89:31:FC 255.255.255.0 192.168.10.1 CISCO SF250-24P C-212 C1 admin umesc_608
C SWITCH 2 BLDG C 192.168.10.6 00:72:78:89:35:F3 255.255.255.0 192.168.10.1 CISCO SF250-24P C-212 C2 admin umesc_608
4 CH SPLITTER BLDG C 92.168.10.12 90:DA:6A:0A:42:5D 255.255.255.0 192.168.10.1 DIGITAL WATCHDOG DW-HDSPOTMOD C-212 admin umesc608
BC-F1-1 BLDG C 192.168.10.30 00:04:7D:41:75:FB 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 8 admin umesc608
BC-F1-2 BLDG C 192.168.10.31 00:04:7D:41:75:FA 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 9 admin umesc608
BC-F1-3 BLDG C 192.168.10.32 00:04:7D:41:75:FC 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 10 admin umesc608
BC-F1-4 BLDG C 192.168.10.33 00:11:35:03:5C:EB 255.255.255.0 192.168.10.1 PELCO EVO-12NJD 2.32 C-212 C1 11 admin umesc608
BC-F1-5x BLDG C 192.168.10.34 00:04:7D:41:71:58 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 C-212 C1 12 admin umesc608
BC-F1-6x BLDG C 192.168.10.47 00:04:7D:41:71:59 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 C-212 C1 4 admin umesc608
BC-F1-7x BLDG C 192.168.10.64 00:04:7D:41:A8:5D 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 C-212 C1 13 admin umesc608
BC-F2-1 BLDG C 192.168.10.35 00:04:7D:41:75:F4 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 14 admin umesc608
BC-F2-2 BLDG C 192.168.10.36 00:04:7D:41:76:04 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 2 admin umesc608
BC-F2-3 BLDG C 192.168.10.37 00:04:7D:41:75:F7 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 15 admin umesc608
BC-F2-4x BLDG C 192.168.10.38 00:04:7D:41:A8:5B 255.255.255.0 192.168.10.1 PELCO IMM12018-1EP 2.13.4.6.8360-A0.0 C-212 C1 16 admin umesc608
BC-F2-5 BLDG C 192.168.10.39 00:04:7D:41:75:C1 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 17 admin umesc608
BC-F2-6 BLDG C 192.168.10.40 00:04:7D:41:75:F5 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 5 admin umesc608
BC-F2-7 BLDG C 192.168.10.41 00:04:7D:41:52:E5 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 18 admin umesc608
BC-F2-8x BLDG C 192.168.10.42 00:04:7D:2A:F3:DF 255.255.255.0 192.168.10.1 PELCO IMM12018-1EP 2.13.4.6.8360-A0.0 C-212 C1 19 admin umesc608
BC-F2-9x BLDG C 192.168.10.43 00:04:7D:41:8E:69 255.255.255.0 192.168.10.1 PELCO IMP531-1ERS 2.32 C-212 C1 3 admin umesc608
NVR BLDG D 192.168.10.2 2C:EA:7F:3E:EE:31 255.255.255.0 192.168.10.1 PELCO VXP-P2-96-6-D D-350b D 24 admin umesc608
D SWITCH BLDG C 192.168.10.7 00:72:78:89:0C:7D 255.255.255.0 192.168.10.1 CISCO SF250-24P D-350b D admin umesc_608
BD-F1-1 BLDG D 192.168.10.44 00:04:7D:41:75:F8 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 5 admin umesc608
BD-F1-2 BLDG D 192.168.10.45 00:04:7D:41:52:E6 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 6 admin umesc608
BD-F1-3 BLDG D 192.168.10.46 00:04:7D:41:75:BE 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 7 admin umesc608
BD-F2-1 BLDG D 192.168.10.48 00:04:7D:41:75:BC 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 8 admin umesc608
BD-F2-2 BLDG D 192.168.10.49 00:04:7D:41:52:E2 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 2 admin umesc608
BD-F2-3 BLDG D 192.168.10.50 00:04:7D:41:75:F6 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 9 admin umesc608
BD-F2-4 BLDG D 192.168.10.51 00:04:7D:41:52:E4 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 10 admin umesc608
BD-F2-5 BLDG D 192.168.10.52 00:04:7D:41:75:F2 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 11 admin umesc608
BD-F2-6X BLDG D 192.168.10.53 00:04:7D:41:70:E1 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 D-350b D 3 admin umesc608
BD-F2-7 BLDG C 192.168.10.65 00:04:7D:41:75:C0 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 D 4 admin umesc608
BG SWITCH HEATED STORAGE 192.168.10.11 00:72:78:89:28:3E 255.255.255.0 192.168.10.1 CISCO SF250-24P G-116 G admin umesc_608
BH-F1-1x HEATED STORAGE 192.168.10.54 00:04:7D:2A:F3:BB 255.255.255.0 192.168.10.1 PELCO IMM12018-1EP 2.13.4.6.8360-A0.0 G-116 G 1 admin umesc608
TB SWITCH TOX BLDG 192.168.10.8 00:72:78:89:25:A3 255.255.255.0 192.168.10.1 CISCO SF250-24P TOX BLDG TS admin umesc_608
TB-F1-1x TOX BLDG 192.168.10.55 00:04:7D:41:71:A3 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 TOX BLDG TS 1 admin umesc608
TB-F1-2x TOX BLDG 192.168.10.56 00:04:7D:41:70:DE 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 TOX BLDG TS 2 admin umesc608
PS SWITCH POND STORAGE 192.168.10.10 00:72:78:89:26:6E 255.255.255.0 192.168.10.1 CISCO SF250-24P POND STORAGE PS admin umesc_608
PS-F1-1x POND STORAGE 192.168.10.57 00:04:7D:41:71:57 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 POND STORAGE PS 1 admin umesc608
PS-F1-2x POND STORAGE 192.168.10.58 00:04:7D:41:71:54 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 POND STORAGE PS 2 admin umesc608
PS-F1-3x POND STORAGE 192.168.10.59 00:04:7dD:2A:F1:4E 255.255.255.0 192.168.10.1 PELCO IMM12018-1EP 2.13.4.6.8360-A0.0 POND STORAGE PS 3 admin umesc608
WH SWITCH WELL HOUSE 2 192.168.10.9 00:72:78:89:2C:6F 255.255.255.0 192.168.10.1 CISCO SF250-24P WELL HOUSE 2 WH2 admin umesc_608
WH-F1-1x WELL HOUSE 2 192.168.10.60 00:04:7D:41:70:DF 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 WELL HOUSE 2 WH2 1 admin umesc608
WH-F1-2x WELL HOUSE 2 192.168.10.61 00:04:7D:41:70:DC 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 WELL HOUSE 2 WH2 2 admin umesc608
VE-F1-1x VEHICLE ENTRANCE 192.168.10.62 00:04:7D:41:70:E0 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 VEHICLE ENTRANCE 1 admin umesc608
VE-F1-2x VEHICLE ENTRANCE 192.168.10.63 00:04:7D:41:71:56 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 VEHICLE ENTRANCE 2 admin umesc608
APHOST P2P BUILDING B 192.168.10.70 3C:0F:C1:04:47:EE 255.255.255.0 192.168.10.1 KCB WES3 VEHICLE ENTRANCE admin umesc608
CLIENT-DWS VEHICLE ENTRANCE 192.168.10.71 3C:0F:C1:04:47:E2 255.255.255.0 192.168.10.1 KCB WES3 BUILDING B admin umesc608
19" EQUIPMENT CABINET
EXISTING FIBER PANEL
NEW CISCO SF250-24P
PoE NETWORK SWITCH
EXISTING HORIZONTAL
LADDER RACK
NEW PELCO VXP 96TB NVR
EXISTING
NETWORK
EQUIPMENT
NEW APC SMART-UPS X 1000VA
NEW APC SMART-UPS X-SERIES
48V EXTERNAL BATTERY PACK
NEW B040-008-19
KVM CONSOLE
EXISTING VERTICAL
LADDER RACK
CEILING
FINISHED FLOOR
CAT6 CABLE ROUTED TO SECOND
FLOOR CAMERA LOCATIONS
EXISTING SLEEVES
CAT6 CABLE ROUTED TO FIRST
FLOOR CAMERA LOCATIONS
EXISTING SLEEVES BETWEEN FLOORS
EXISTING FIBER BACKBONE CABLE
BETWEEN IT ROOMS D-350b AND C-212
19" EQUIPMENT CABINET
EXISTING FIBER PANEL
NEW CISCO SF250-24P
PoE NETWORK SWITCH
EXISTING
NETWORK
EQUIPMENT
NEW APC SMART-UPS X 1000VA
CEILING
FINISHED FLOOR
CAT6 CABLE ROUTED TO SECOND
FLOOR CAMERA LOCATIONS
EXISTING SLEEVES
EXISTING FIBER BACKBONE CABLE
BETWEEN IT ROOMS
19" EQUIPMENT CABINET
EXISTING FIBER PANEL
NEW CISCO SF250-24P
PoE NETWORK SWITCH
EXISTING
NETWORK
EQUIPMENT
NEW APC SMART-UPS X 1000VA
CEILING
FINISHED FLOOR
ENHANCED CAT6 CABLE ROUTED TO
SECOND FLOOR CAMERA LOCATIONS
EXISTING SLEEVES
EXISTING FIBER BACKBONE CABLE
BETWEEN IT ROOMS B-219 AND C-212
CISCO SF250-24P
PoE NETWORK SWITCH
FINISHED FLOOR
EXISTING UNDERGROUND
CONDUIT
APC BATTERY BACKUP
2' X 2' PLYWOOD BACKBOARD
J-HOOK CABLE SUPPORT SYSTEM
CAT6 CABLE TO CAMERA LOCATIONSCAT6 CABLE TO CAMERA LOCATIONS
CONDUIT STUB UP W/ BUSHING
EXISTING FIBER
ENCLOSURE
EXISTING FIBER BACKBONE
ROUTED TO BUILDING C
IT ROOM C-212
FIBER PATCH CABLE TO NEW CISCO SWITCH
CONDUIT WITH POWER CABLE
TO EXISTING AC OUTLET
EXISTING 120VAC
POWER OUTLET
6U WALL MOUNTED LOCKED
EQUIPMENT ENCLOSURE
1. ALL LOCATIONS SHOWN ARE NOT EXACT
LOCATIONS. ACTUAL MOUNTING HEIGHTS
AND LOCATIONS NEED TO BE FIELD VERIFIED
BEFORE INSTALLATION.
2. ALL EXTERIOR DEVICES WILL REQUIRE AN
EXTERIOR GRADE CAT6 CABLE.
3. ALL EXTERIOR PENETRATIONS ARE TO BE
SEALED WITH CLEAR WEATHERPROOF
SILICON CAULK.
4. TERMINATE EXTERIOR CAT6 CABLE ON DITEK
SURGE PROTECTORS. ROUTE 14AWG
GROUND CABLE TO EXISTING TGB OR TGBM.
5. REPLACE ANY FIRECAULK THAT IS
DISTURBED OR REMOVED FORM EXISTING
SLEEVES.
GENERAL NOTES: scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
CCV EQUIPMENT
DETAILS
T-501
SCALE: AS NOTED
1 AS-BUILT DRAWINGS 11/19/2020
SCALE:
T-401 BUILDING D IT ROOM D-350b EQUIPMENT ELEVATION
1/8" = 1'
SCALE:
T-401
BUILDING C IT ROOM C-212 EQUIPMENT ELEVATION
1/8" = 1'SCALE:
T-401
BUILDING B IT ROOM B-219 EQUIPMENT ELEVATION
1/8" = 1'
SCALE:
T-401
TYPICAL 6U ENCLOSURE ELEVATION
1/8" = 1'
19" EQUIPMENT CABINET
EXISTING FIBER PANEL
NEW CISCO SF250-24P
PoE NETWORK SWITCH
EXISTING HORIZONTAL
LADDER RACK
NEW PELCO VXP 96TB NVR
EXISTING
NETWORK
EQUIPMENT
NEW APC SMART-UPS X 1000VA
NEW APC SMART-UPS X-SERIES
48V EXTERNAL BATTERY PACK
NEW B040-008-19
KVM CONSOLE
EXISTING VERTICAL
LADDER RACK
CEILING
FINISHED FLOOR
CAT6 CABLE ROUTED TO SECOND
FLOOR CAMERA LOCATIONS
EXISTING SLEEVES
CAT6 CABLE ROUTED TO FIRST
FLOOR CAMERA LOCATIONS
EXISTING SLEEVES BETWEEN FLOORS
EXISTING FIBER BACKBONE CABLE
BETWEEN IT ROOMS D-350b AND C-212
19" EQUIPMENT CABINET
EXISTING FIBER PANEL
NEW CISCO SF250-24P
PoE NETWORK SWITCH
EXISTING
NETWORK
EQUIPMENT
NEW APC SMART-UPS X 1000VA
CEILING
FINISHED FLOOR
CAT6 CABLE ROUTED TO SECOND
FLOOR CAMERA LOCATIONS
EXISTING SLEEVES
EXISTING FIBER BACKBONE CABLE
BETWEEN IT ROOMS
19" EQUIPMENT CABINET
EXISTING FIBER PANEL
NEW CISCO SF250-24P
PoE NETWORK SWITCH
EXISTING
NETWORK
EQUIPMENT
NEW APC SMART-UPS X 1000VA
CEILING
FINISHED FLOOR
ENHANCED CAT6 CABLE ROUTED TO
SECOND FLOOR CAMERA LOCATIONS
EXISTING SLEEVES
EXISTING FIBER BACKBONE CABLE
BETWEEN IT ROOMS B-219 AND C-212
CISCO SF250-24P
PoE NETWORK SWITCH
FINISHED FLOOR
EXISTING UNDERGROUND
CONDUIT
APC BATTERY BACKUP
2' X 2' PLYWOOD BACKBOARD
J-HOOK CABLE SUPPORT SYSTEM
CAT6 CABLE TO CAMERA LOCATIONSCAT6 CABLE TO CAMERA LOCATIONS
CONDUIT STUB UP W/ BUSHING
EXISTING FIBER
ENCLOSURE
EXISTING FIBER BACKBONE
ROUTED TO BUILDING C
IT ROOM C-212
FIBER PATCH CABLE TO NEW CISCO SWITCH
CONDUIT WITH POWER CABLE
TO EXISTING AC OUTLET
EXISTING 120VAC
POWER OUTLET
6U WALL MOUNTED LOCKED
EQUIPMENT ENCLOSURE
1. ALL LOCATIONS SHOWN ARE NOT EXACT
LOCATIONS. ACTUAL MOUNTING HEIGHTS
AND LOCATIONS NEED TO BE FIELD VERIFIED
BEFORE INSTALLATION.
2. ALL EXTERIOR DEVICES WILL REQUIRE AN
EXTERIOR GRADE CAT6 CABLE.
3. ALL EXTERIOR PENETRATIONS ARE TO BE
SEALED WITH CLEAR WEATHERPROOF
SILICON CAULK.
4. TERMINATE EXTERIOR CAT6 CABLE ON DITEK
SURGE PROTECTORS. ROUTE 14AWG
GROUND CABLE TO EXISTING TGB OR TGBM.
5. REPLACE ANY FIRECAULK THAT IS
DISTURBED OR REMOVED FORM EXISTING
SLEEVES.
GENERAL NOTES: scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
CCV EQUIPMENT
DETAILS
T-501
SCALE: AS NOTED
1 AS-BUILT DRAWINGS 11/19/2020
SCALE:
T-401 BUILDING D IT ROOM D-350b EQUIPMENT ELEVATION
1/8" = 1'
SCALE:
T-401
BUILDING C IT ROOM C-212 EQUIPMENT ELEVATION
1/8" = 1'SCALE:
T-401
BUILDING B IT ROOM B-219 EQUIPMENT ELEVATION
1/8" = 1'
SCALE:
T-401
TYPICAL 6U ENCLOSURE ELEVATION
1/8" = 1'
1. ALL LOCATIONS SHOWN ARE NOT EXACT
LOCATIONS. ACTUAL MOUNTING HEIGHTS
AND LOCATIONS NEED TO BE FIELD VERIFIED
BEFORE INSTALLATION.
2. ALL EXTERIOR DEVICES WILL REQUIRE AN
EXTERIOR GRADE CAT6 CABLE.
3. ALL EXTERIOR PENETRATIONS ARE TO BE
SEALED WITH CLEAR WEATHERPROOF
SILICON CAULK.
4. TERMINATE CAT6 CABLE ON DITEK SURGE
PROTECTORS. ROUTE 14AWG GROUND
CABLE TO GROUND LUG ON THE BACK OF
THE APC BATTERY BACKUP.
5. ALL CABLES TO BE CABLE SUPPORTED BY
J-HOOKS OR EQUIVALENT APPROVED CABLE
SUPPORT SYSTEM.
GENERAL NOTES: scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
CCV EQUIPMENT
DETAILS
T-501
SCALE: AS NOTED
1 AS-BUILT DRAWINGS 11/19/2020
SCALE:
T-501
INTERIOR CEILING MOUNT DOME CAMERA DETAIL
1:16
(1) CAT6 CABLE ROUTED ABOVE
CEILING TO NEAREST IT CLOSET
J-HOOK CABLE SUPPORT SYSTEM
DROP CEILING
FINISHED FLOOR
PELCO IMP531-1IRS
5MP DOME CAMERA
10' CAT6 SERVICE LOOP
TOGGLEBOLT SUPPORT SCREWS (1) CAT6 CABLE ROUTED ABOVE
CEILING TO NEAREST IT CLOSET
J-HOOK CABLE SUPPORT SYSTEM
DROP CEILING
FINISHED FLOOR
PELCO EVO-12NJD
12MP FISH EYE CAMERA
10' CAT6 SERVICE LOOP
TOGGLEBOLT SUPPORT SCREWS
SCALE:
T-501
INTERIOR CEILING MOUNT FISHEYE CAMERA DETAIL
1:16
(1) CAT6 CABLE ROUTED ABOVE
CEILING TO NEAREST IT CLOSET
J-HOOK CABLE SUPPORT SYSTEM
DROP CEILING
PELCO IBP531-1ER
5MP BULLET CAMERA
10' CAT6 SERVICE LOOP CONDUIT BACKBOX
FINISHED FLOOR
CONDUIT SLEEVE W/ BUSHING
EXISTING STRUCTURE
(1) CAT6 CABLE ROUTED ABOVE
CEILING TO NEAREST IT CLOSET
J-HOOK CABLE SUPPORT SYSTEM
DROP CEILING PELCO IMP531-1IRS
5MP DOME CAMERA
10' CAT6 SERVICE LOOP CONDUIT BACKBOX
FINISHED FLOOR
CONDUIT SLEEVE W/ BUSHING
EXISTING STRUCTURE
PELCO IMP531-1IRS
5MP DOME CAMERA
EXISTING STRUCTURE
PELCO WALL MOUNT
PELCO PENDANT
MOUNT ADPATER
WEATHERPROOF JUNCTION
BOX W/ FLEX CONDUIT
PELCO CORNER MOUNT
SCALE:
T-501
EXTERIOR WALL MOUNT BULLET CAMERA DETAIL
1:16
SCALE:
T-501
EXTERIOR WALL MOUNT DOME CAMERA DETAIL
1:16 SCALE:
T-501
EXTERIOR CORNER MOUNT DOME CAMERA DETAIL
1:16
32" WALL MOUNTED MONITOR
SCALE:
T-501
BUILDING C ROOM C-213 SECURITY MONITORING DETAIL
1:10
HD SPOT MONITOR
HDMI INPUT TO 32" MONITOR
120VAC POWER CABLE
(1) CAT6 CABLE ROUTED
THROUGH WALL TO
ACCESSIBLE CEILING SPACE
10' CAT6 SERVICE LOOP
J-HOOK CABLE SUPPORT SYSTEM
scDataCom
2700 GREGORY ST SUITE 180
SAVANNAH, GA 31405
912-777-5721
CHECKED BY:
DRAWN BY:
DATE:
PROJECT #:
REV DESCRIPTION DATE
THIS DRAWING, AND ALL INFORMATION
CONTAINED HEREIN IS PROPRIETARY AND
IS PROPERTY OF SCDATACOM. ANY USE,
DISSEMINATION OR REPRODUCTION
WITHOUT THE WRITTEN PERMISSION OF
SCDATACOM IS PROHIBITED.
U
PP
ER
M
ID
W
ES
T
EN
VI
R O
N M
EN
TA
L
SC
IE
N
C E
C
EN
TE
R
C C
V U
PG
R
AD
E
F
AN
TA
R
EE
D
R O
AD
LA
C R
O
SS
E, W
I 5
140G0220P0223 07/16/2020
DLM
DLM
CCV RISER
DIAGRAM
T-601
SCALE: NTS
1 AS-BUILT DRAWINGS 11/19/2020
SCALE:
T-601
CCV RISER DIAGRAM
NTS
BUILDING A
IT ROOM A-101
APC BATTERY
BACKUP
CISCO 24 PORT
PoE SWITCH
120VAC POWER
BA-F1-2
BA-F1-2
BUILDING A FIRST
FLOOR CAMERAS
BA-F2-3x
BA-F2-1
BUILDING A SECOND
FLOOR CAMERAS
BA-F2-2
BUILDING A
CAT6 CABLE
BB-F1-1
BB-F1-2
BUILDING B
SECOND
FLOOR CAMERAS
BB-F2-5x
BB-F2-1
BUILDING B FIRST
FLOOR CAMERAS
BB-F2-2
BB-F2-3x
BUILDING B SECOND
FLOOR P2P
BUILDING B
IT ROOM B-219
APC BATTERY
BACKUP
CISCO 24 PORT
PoE SWITCH
120VAC POWER
BUILDING B
FIBER
ENCLOSURE
BUILDING C
IT ROOM C-212
APC BATTERY
BACKUP
CISCO 24 PORT
PoE SWITCH
CAT6
CABLE
BC-F1-1
BC-F1-7x
BUILDING C FIRST
FLOOR CAMERAS
BC-F2-1
BC-F2-2
BUILDING C
BC-F2-3
BC-F2-4x
BC-F2-5
BC-F2-9x
BUILDING C SECOND
FLOOR CAMERAS
BC-F1-6x
BC-F1-5x
BC-F1-4
BC-F1-3
BC-F1-2
BUILDING C
ROOM C-213
32" MONITOR
HD SPOT
MONITOR
APC BATTERY
BACKUP
120VAC POWER CABLE
FIBER
ENCLOSURE
CAT6 CABLE
HDMI CABLE
120VAC POWER CABLE
BUILDING D
IT ROOM D-350b
APC BATTERY
BACKUP
CISCO 24 PORT
PoE SWITCH
CAT6 CABLE BD-F2-1
BUILDING D FIRST
FLOOR CAMERAS
BD-F1-1
BD-F1-2
BUILDING D
BD-F1-3
(2) APC BATTERY
PACK
BUILDING D SECOND
FLOOR CAMERAS
BD-F2-2
BD-F2-3
BD-F2-14
BD-F2-5
BD-F2-6x
KVM
PELCO NVR
TRIPPLITE KVM - PS780 CABLE
120VAC POWER CABLE
FIBER
ENCLOSURE
MM OM1 CAMPUS FIBER
BACKBONE CABLE
LC DUPLEX FIBER CABLE(S)
LC DUPLEX
FIBER CABLE
CAT6 CABLE
CAT6
CABLE
VEHICLE ENTRANCE
POLE
POLE MOUNT ENCLOSURE
NETWORK
SWITCH
VE-F1-1x
VE-F1-2x
VE-F1-3x
VEHICLE
ENTRANCE
P2P
VEHICLE
ENTRANCE
CAMERAS
BUILDING G
IT ROOM G-116
APC BATTERY
BACKUP
CISCO 24 PORT
PoE SWITCH
120VAC POWER
HS-F1-1x
HEATED STORAGE
CAMERA
BUILDING G
FIBER
ENCLOSURE
CAT6 CABLE
LC DUPLEX
FIBER CABLE
6U EQUIPMENT
ENCLOSURE
APC BATTERY
BACKUP
CISCO 24 PORT
PoE SWITCH
120VAC POWER
POND STORGE
FIBER
ENCLOSURE
LC DUPLEX
FIBER CABLE
CAT6
CABLE
PS-F1-2x
PS-F1-1x
POND STORAGE
CAMERAS
6U EQUIPMENT
ENCLOSURE
APC BATTERY
BACKUP
CISCO 24 PORT
PoE SWITCH
120VAC POWER
TOX. BUILDING
FIBER
ENCLOSURE
LC/SC DUPLEX
FIBER CABLE
CAT6
CABLE
TX-F1-2x
TX-F1-1x
TOX BUILDING
CAMERAS
PS-F1-3x
CAT6 CABLE
POINT TO POINT SIGNAL
FIBER
ENCLOSURE
BUILDING C
ROOM C-214
CISCO 24 PORT
PoE SWITCH
WELLHOUSE 2 IDF
APC BATTERY
BACKUP
CISCO 24 PORT
PoE SWITCH
120VAC POWER
WH2-F1-1x
BOAT STORAGE
CAMERA
WELLHOUSE 2
FIBER
ENCLOSURE
CAT6 CABLE
LC DUPLEX
FIBER CABLE
MM OM1 CAMPUS FIBER
BACKBONE CABLE
MM OM1 CAMPUS FIBER
BACKBONE CABLE
MM OM1 CAMPUS FIBER
BACKBONE CABLE
MM OM1 CAMPUS FIBER
BACKBONE CABLE
MM OM1
CAMPUS FIBER
BACKBONE
CABLE
LC DUPLEX FIBER CABLE(S)
TO MM SFP MODULES
EXISTING
UNDERGROUND
CONDUIT
BC-F2-6
BC-F2-7
BC-F2-8x
WH2-F1-2x
LC/SC DUPLEX FIBER CABLE
TO MM SFP MODULES
| Pages from Exhibit A _CCTV_Plan |
| Exhibit A _CCTV_Plan |
| p2 |
| p3 |
| p4 |
| p5 |
| p6 |
| p7 |
| p8 |
| p9 |
| p10 |
| p11 |
| p12 |
| p13 |
| p14 |
File details come from the government source that posted it. Updated .