l;\fll HOUSE 3

SURGE

POND

REARING

PONDS

VEHICLE

ENTRANCE

f

EAST PARKING

LOT

BtllLDiNG G HEATED

STORAGE

SOUTH

PARKING

LOT

CCV SITE PLAN

SCALE: NTS

NEWCAM#1NEWCAM#1

NEWCAM#1NEWCAM#2

mgoede Highlight mgoede Highlight

U P

FISH HOLDING HOUSE

ELEV

UP

UP

UP

UP

A

B

C

CORE

STOR.

MENWOMEN

JAN.

STOR.

PHYS.

BEHAV.

WOMEN MEN

CORE

WEIGH

UP

JAR

WASH

4a

WATER

WATER

CHEM.

4b

FLOWING

ASSAY LAB

EFFICACY

LAB

39A

39L

EFFICACY

LAB

3a

3b

INVERT.

WET LAB

TOXIC

PREP

1a OFFICE

OFFICE

OFFICE

OFFICE

PHYS.

PREP

12b

OFFICE

FLOWING

ASSAY LAB

PHYS.

WET LAB

INVERT.

WET LAB

LAB

16a

INVERT.

PREP

BALN.

ROOM

17a

TOXIC

PREP

BAL.

15b

CHEM.

STOR.

15a

EQUIP.

34a

STATIC

ASSAY LAB

RECEIVING

BOILER

ROOM

GC2 GC1

MECH.

EQUIP.

LIBRARY

JAN.

CONF.

RM

GEN.

ELEV.

EQUIP.

ELEC.

OFFICE

INVERT

LAB

21a

INVERT

LAB

21b

OFFICE

21c

DIAG

LAB

21d

PREP &

STOR.

21e

E

P A N E L S

E

P A N E L S

E L E C

P A N E L S

GC3

PUMP

ROOM

E

P A N E L S

E

P A N E L S

DUCT

MECH

EQUIP

AHU

CONDENSING

UNIT

BC-F1-5X

BC-F1-4

BA-F1-1

BA-F1-2

BB-F1-1

BB-F1-2

BC-F1-2

BC-F1-1

BC-F1-3

BC-F1-7X

BC-F1-6X

SCALE:

T-101

LAB/OFFICE LOWER LEVEL CCV PLAN

3/32" = 1'

1. ALL LOCATIONS SHOWN ARE NOT EXACT

LOCATIONS. ACTUAL MOUNTING HEIGHTS

AND LOCATIONS NEED TO BE FIELD VERIFIED

BEFORE INSTALLATION.

2. ALL EXTERIOR DEVICES WILL REQUIRE AN

EXTERIOR GRADE ENHANCED CAT6 CABLE.

3. ALL EXTERIOR PENETRATIONS ARE TO BE

SEALED WITH CLEAR WEATHERPROOF

SILICON CAULK.

4. TERMINATE EXTERIOR ENHANCED CAT6

CABLE ON DITEK SURGE PROTECTORS.

ROUTE 14AWG GROUND CABLE TO TMGB OR

TGB.

5. ALL CABLES TO BE SUPPORTED BY J-HOOKS

OR EQUIVALENT APPROVED CABLE SUPPORT

SYSTEM.

CONDUIT SLEEVE BETWEEN FLOORS.

CABLES ROUTING BETWEEN OPEN STRUCTURE

BETWEEN FLOORS.

KEYED NOTES:

scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

LAB/OFFICE LOWER

LEVEL CCV PLAN

T-101

SCALE: 3/32" = 1'

1 AS-BUILT DRAWINGS 11/19/2020

GENERAL NOTES:

BC-F1-7X

NEWCAM#3

mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Callout

ELEV

RECEPTION/

EXHIBIT

DN

A

B

C

CORE

CORE

DN

DN

DN

D N

VEST.

SECRETARY

DN

OFFICE

ADMIN. MACHINE

WORK AREA

MECH

EQUIP

AHU 1

MECH

EQUIP

MECH

EQUIP

MECH

EQUIP

AHU 2

DUCT DUCT

DUCTDUCT

MECH

EQUIP

AHU

MECH

EQUIP

AHU

E

P A N E L S

ROOF

HATCH

BA-F2-1

BA-F2-2

BB-F2-2

BB-F2-1

BC-F2-2

BC-F2-3

BC-F2-7

BC-F2-6

BC-F2-1

BC-F2-5

IT ROOM

B-219

IT ROOM

C-212

P

IT ROOM

A-101

BA-F2-3X

BC-F2-8x

BB-F2-3X

BC-F2-4x

BC-F2-9x

SCALE:

T-102

LAB/OFFICE UPPER LEVEL CCV PLAN

3/32" = 1'

1. ALL LOCATIONS SHOWN ARE NOT EXACT

LOCATIONS. ACTUAL MOUNTING HEIGHTS

AND LOCATIONS NEED TO BE FIELD VERIFIED

BEFORE INSTALLATION.

2. ALL EXTERIOR DEVICES WILL REQUIRE AN

EXTERIOR GRADE ENHANCED CAT6 CABLE.

3. ALL EXTERIOR PENETRATIONS ARE TO BE

SEALED WITH CLEAR WEATHERPROOF

SILICON CAULK.

4. TERMINATE EXTERIOR ENHANCED CAT6

CABLE ON DITEK SURGE PROTECTORS.

ROUTE 14AWG GROUND CABLE TO TMGB OR

TGB.

5. ALL CABLES TO BE SUPPORTED BY J-HOOKS

OR EQUIVALENT APPROVED CABLE SUPPORT

SYSTEM.

EXISTING FIBER PATHWAY BETWEEN IT ROOM

C-212 AND B-219.

EXISTING FIBER PATHWAY BETWEEN IT ROOM

C-212 AND D-350b.

EXISTING FIBER PATHWAY BETWEEN IT ROOM

C-212 AND G-116.

EXISTING FIBER PATHWAY BETWEEN IT ROOM

C-212 AND POND STORAGE.

CCV EQUIPMENT LOCATION.

CONDUIT SLEEVE BETWEEN FLOORS.

NEW ENHANCED CAT6 BACKBONE CABLE

BETWEEN IT ROOM A-101 AND IT ROOM B-219.

CABLES ROUTING BETWEEN OPEN STRUCTURE

BETWEEN FLOORS.

EXISTING FIBER PATHWAY BETWEEN IT ROOM

C-212 AND WELL HOUSE 2.

FIBER PATCH CABLE BETWEEN IT ROOM C-214

AND IT ROOM C-212.

EXISTING FIBER PATHWAY BETWEEN IT ROOM

C-212 AND TOX BUILDING.

KEYED NOTES:

scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

LAB/OFFICE UPPER

LEVEL CCV PLAN

T-102

SCALE: 3/32" = 1'

1 AS-BUILT DRAWINGS 11/19/2020

GENERAL NOTES:

T-401

T-401

T-401 5

11 NEWCAM#4

mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight

BD-F1-3

BD-F1-2

BD-F1-1

SCALE:

T-103

BUILDING D LOWER LEVEL CCV PLAN

3/32" = 1'

1. ALL LOCATIONS SHOWN ARE NOT EXACT

LOCATIONS. ACTUAL MOUNTING HEIGHTS

AND LOCATIONS NEED TO BE FIELD VERIFIED

BEFORE INSTALLATION.

2. ALL EXTERIOR DEVICES WILL REQUIRE AN

EXTERIOR GRADE ENHANCED CAT6 CABLE.

3. ALL EXTERIOR PENETRATIONS ARE TO BE

SEALED WITH CLEAR WEATHERPROOF

SILICON CAULK.

4. TERMINATE EXTERIOR ENHANCED CAT6

CABLE ON DITEK SURGE PROTECTORS.

ROUTE 14AWG GROUND CABLE TO TMGB OR

TGB.

5. ALL CABLES TO BE SUPPORTED BY J-HOOKS

OR EQUIVALENT APPROVED CABLE SUPPORT

SYSTEM.

scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

BUILDING D LOWER

LEVEL CCV PLAN

T-103

SCALE: 3/32" = 1'

1 AS-BUILT DRAWINGS 11/19/2020

GENERAL NOTES:

CONDUIT SLEEVE BETWEEN FLOORS.1

KEYED NOTES:

NEWCAM#5

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FE

AutoCAD SHX Text

FEC

mgoede Highlight mgoede Highlight mgoede Highlight

BD-F2-6X

BD-F2-1

BD-F2-5

BD-F2-4

BD-F2-3

BD-F2-2

BD-F2-6

IT ROOM

D-350b

1. ALL LOCATIONS SHOWN ARE NOT EXACT

LOCATIONS. ACTUAL MOUNTING HEIGHTS

AND LOCATIONS NEED TO BE FIELD VERIFIED

BEFORE INSTALLATION.

2. ALL EXTERIOR DEVICES WILL REQUIRE AN

EXTERIOR GRADE ENHANCED CAT6 CABLE.

3. ALL EXTERIOR PENETRATIONS ARE TO BE

SEALED WITH CLEAR WEATHERPROOF

SILICON CAULK.

4. TERMINATE EXTERIOR ENHANCED CAT6

CABLE ON DITEK SURGE PROTECTORS.

ROUTE 14AWG GROUND CABLE TO TMGB OR

TGB.

5. ALL CABLES TO BE SUPPORTED BY J-HOOKS

OR EQUIVALENT APPROVED CABLE SUPPORT

SYSTEM.

GENERAL NOTES:

SCALE:

T-104

BUILDING D UPPER LEVEL CCV PLAN

3/32" = 1'

EXISTING FIBER PATHWAY BETWEEN IT ROOM

C-212 AND B-219.

CCV EQUIPMENT LOCATION.

CONDUIT SLEEVE BETWEEN FLOORS.

KEYED NOTES:

scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

BUILDING D UPPER

LEVEL CCV PLAN

T-104

SCALE: 3/32" = 1'

1 AS-BUILT DRAWINGS 11/19/2020

T-401

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text F.E.

AutoCAD SHX Text

EXG.

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight

SOUTH CHEMICAL

BUNKER

SOUTH CHEMICAL

BUNKER

NORTH CHEMICAL

BUNKER

NORTH CHEMICAL

BUNKER

OFFICEGIS

STORAGE

LOCKER

OFFICES

SPRINKLER

RISER ROOM

BREAK

ROOM STORAGE

COMMONS

CLOSET

OFFICE OFFICE OFFICE OFFICE

CONFERENCE HALL

OFFICE OFFICE OFFICE

OFFICEOFFICEOFFICE

BH-F1-1x

SCALE:

T-105

HEATED STORAGE CCV PLAN

1/8" = 1'

SCALE:

T-105

BUILDING G / CHEMICAL BUNKER CCV PLAN

1/8" = 1'

1. ALL LOCATIONS SHOWN ARE NOT EXACT

LOCATIONS. ACTUAL MOUNTING HEIGHTS

AND LOCATIONS NEED TO BE FIELD VERIFIED

BEFORE INSTALLATION.

2. ALL EXTERIOR DEVICES WILL REQUIRE AN

EXTERIOR GRADE ENHANCED CAT6 CABLE.

3. ALL EXTERIOR PENETRATIONS ARE TO BE

SEALED WITH CLEAR WEATHERPROOF

SILICON CAULK.

4. TERMINATE EXTERIOR ENHANCED CAT6

CABLE ON DITEK SURGE PROTECTORS.

ROUTE 14AWG GROUND CABLE TO TMGB OR

TGB.

5. ALL CABLES TO BE SUPPORTED BY J-HOOKS

OR EQUIVALENT APPROVED CABLE SUPPORT

SYSTEM.

GENERAL NOTES:

CCV EQUIPMENT LOCATION.

EXISTING CONDUIT SLEEVE BETWEEN HEATED

STORAGE AND IT ROOM G-116.

KEYED NOTES:

scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

HEATED STORAGE AND

BLDG G CCV PLAN

T-105

SCALE: 1/8" = 1'

1 AS-BUILT DRAWINGS 11/19/2020

T-401

NEWCAM#6

AutoCAD SHX Text G-5

AutoCAD SHX Text G-1

AutoCAD SHX Text G-6

AutoCAD SHX Text G-4

AutoCAD SHX Text G-2

AutoCAD SHX Text G-7

AutoCAD SHX Text G-24

AutoCAD SHX Text G-23

AutoCAD SHX Text G-22

AutoCAD SHX Text G-21

AutoCAD SHX Text G-8

AutoCAD SHX Text G-9

AutoCAD SHX Text G-10

AutoCAD SHX Text G-11

AutoCAD SHX Text G-20

AutoCAD SHX Text G-19

AutoCAD SHX Text G-12

AutoCAD SHX Text G-13

AutoCAD SHX Text G-14

AutoCAD SHX Text G-16

AutoCAD SHX Text G-17

AutoCAD SHX Text G-18 mgoede Highlight

WH2-F1-2x

WH2-F1-2x

SCALE:

T-106

WELL HOUSE 2 CCV PLAN

3/32" = 1'

1. ALL LOCATIONS SHOWN ARE NOT EXACT

LOCATIONS. ACTUAL MOUNTING HEIGHTS

AND LOCATIONS NEED TO BE FIELD VERIFIED

BEFORE INSTALLATION.

2. ALL EXTERIOR DEVICES WILL REQUIRE AN

EXTERIOR GRADE ENHANCED CAT6 CABLE.

3. ALL EXTERIOR PENETRATIONS ARE TO BE

SEALED WITH CLEAR WEATHERPROOF

SILICON CAULK.

4. TERMINATE EXTERIOR ENHANCED CAT6

CABLE ON DITEK SURGE PROTECTORS.

ROUTE 14AWG GROUND CABLE TO TMGB OR

TGB.

5. ALL CABLES TO BE SUPPORTED BY J-HOOKS

OR EQUIVALENT APPROVED CABLE SUPPORT

SYSTEM.

GENERAL NOTES:

CCV EQUIPMENT LOCATION.

EXISTING UNDERGROUND CONDUIT BETWEEN

BUILDINGS. ROUTE (2) CAT6 CABLE TO

CAMERAS.

KEYED NOTES:

scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

WELL HOUSE 2

CCV PLAN

T-106

SCALE: 3/32" = 1'

1 AS-BUILT DRAWINGS 11/19/2020

T-401 mgoede Highlight

PS-F1-1x PS-F1-2x

PS-F1-3x

TB-F1-2x

TB-F1-1x

SCALE:

T-107

POND STORAGE CCV PLAN

1/8" = 1'

1. ALL LOCATIONS SHOWN ARE NOT EXACT

LOCATIONS. ACTUAL MOUNTING HEIGHTS

AND LOCATIONS NEED TO BE FIELD VERIFIED

BEFORE INSTALLATION.

2. ALL EXTERIOR DEVICES WILL REQUIRE AN

EXTERIOR GRADE ENHANCED CAT6 CABLE.

3. ALL EXTERIOR PENETRATIONS ARE TO BE

SEALED WITH CLEAR WEATHERPROOF

SILICON CAULK.

4. TERMINATE EXTERIOR ENHANCED CAT6

CABLE ON DITEK SURGE PROTECTORS.

ROUTE 14AWG GROUND CABLE TO TMGB OR

TGB.

5. ALL CABLES TO BE SUPPORTED BY J-HOOKS

OR EQUIVALENT APPROVED CABLE SUPPORT

SYSTEM.

GENERAL NOTES:

CCV EQUIPMENT LOCATION.1

KEYED NOTES:

scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

POND STORAGE AND

TOX. BLDG CCV PLAN

T-107

SCALE: 1/8" = 1'

1 AS-BUILT DRAWINGS 11/19/2020

T-401

T-401

SCALE:

T-107

TOX. BUILDING CCV PLAN

1/8" = 1' mgoede Highlight mgoede Highlight mgoede Highlight mgoede Highlight

VE-F1-2x

VE-F1-1x

P

SCALE:

T-108

VEHICLE ENTRANCE POLE DETAIL

1:10

1. ALL LOCATIONS SHOWN ARE NOT EXACT

LOCATIONS. ACTUAL MOUNTING HEIGHTS

AND LOCATIONS NEED TO BE FIELD VERIFIED

BEFORE INSTALLATION.

2. ALL EXTERIOR DEVICES WILL REQUIRE AN

EXTERIOR GRADE ENHANCED CAT6 CABLE.

3. ALL EXTERIOR PENETRATIONS ARE TO BE

SEALED WITH CLEAR WEATHERPROOF

SILICON CAULK.

4. TERMINATE EXTERIOR ENHANCED CAT6

CABLE ON DITEK SURGE PROTECTORS.

ROUTE 14AWG GROUND CABLE TO

ELECTRICAL GROUND.

5. USE EXISTING CABLE AND EQUIPMENT

WHERE APPLICABLE. ONLY USE CABLE THAT

PASSES TIA/EIA CABLE TEST.

scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

VEHICLE ENTRANCE

CCV POLE PLAN

T-108

SCALE: AS NOTED

1 AS-BUILT DRAWINGS 11/19/2020

GENERAL NOTES:

T-108

EXISTING POINT TO POINT BACK TO BUILDING B

NEW PELCO IBP531-1ER

TEST AND USE EXISTING CABLE

IF POSSIBLE

EXISTING POLE MOUNTED

WEATHERPROOF ENCLOSURE

USE EXISTING EQUIPMENT

WHERE APPLICABLE

EXISTING POLE

EXISTING CONCRETE PEDESTAL

FINISHED GRADE

NEW PELCO IBP531-1ER

TEST AND USE EXISTING CABLE

IF POSSIBLE

CAT6 CABLE ROUTED

THROUGH POLE TO ENCLOSURE

USE EXISTING POWER

SUPPLIED BY OTHERS

SCALE:

T-108

VEHICLE ENTRANCE CCV PLAN

3/32" = 1'

(1) ENHANCED CAT6 CABLE ROUTED ABOVE

CEILING TO NEAREST IT CLOSET

J-HOOK CABLE SUPPORT SYSTEM

DROP CEILING

EXTERIOR CAT6

10' ENHANCED

CAT6 SERVICE LOOP

FINISHED FLOOR

CONDUIT SLEEVE W/ BUSHING

BUILDING B

EXISTING STRUCTURE

EXISTING POINT TO POINT

UNIT TO VEHICLE ENTRANCE

SCALE:

T-108

VEHICLE ENTRANCE POINT TO POINT DETAIL

1:10 mgoede Highlight scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

CCV EQUIPMENT

SCHEDULE

T-201

SCALE: NTS

1 AS-BUILT DRAWINGS 11/19/2020

SCALE:

T-201

CCV EQUIPMENT SCHEDULE

NTS

Device Name Building IP Address MAC Address Subnet Mask Gateway Type Model Firmware IDF / MDF Switch # Port # Username Password

A SWITCH BLDG A 192.168.10.3 00:72:78:89:2F:0A 255.255.255.0 192.168.10.1 CISCO SF250-24P A-101 admin umesc_608

BA-F1-1 BLDG A 192.168.10.20 00:04:7D:41:75:BD 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 A-101 A 1 admin umesc608

BA-F1-2 BLDG A 192.168.10.21 00:04:7D:41:52:E7 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 A-101 A 2 admin umesc608

BA-F2-1 BLDG A 192.168.10.22 00:04:7D:41:75:F3 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 A-101 A 3 admin umesc608

BA-F2-2 BLDG A 192.168.10.23 00:04:7D:41:75:BF 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 A-101 A 4 admin umesc608

BA-F2-3x BLDG A 192.168.10.24 00:04:7D:41:70:DD 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 A-101 A 5 admin umesc608

B SWITCH BLDG B 192.168.10.4 00:72:78:89:2E:3F 255.255.255.0 192.168.10.1 CISCO SF250-24P 2.32 A-101 admin umesc_608

BB-F1-1 BLDG B 192.168.10.25 00:04:7D:41:52:E3 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 B-219 B 1 admin umesc608

BB-F1-2 BLDG B 192.168.10.26 00:04:7D:41:75:FD 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 B-219 B 2 admin umesc608

BB-F2-1 BLDG B 192.168.10.27 00:04:7D:41:75:F9 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 B-219 B 3 admin umesc608

BB-F2-2 BLDG B 192.168.10.28 00:04:7D:41:75:C9 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 B-219 B 4 admin umesc608

BB-F2-3x BLDG B 192.168.10.29 00:04:7D:41:71:A2 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 B-219 B 5 admin umesc608

C SWITCH BLDG C 192.168.10.5 00:72:78:89:31:FC 255.255.255.0 192.168.10.1 CISCO SF250-24P C-212 C1 admin umesc_608

C SWITCH 2 BLDG C 192.168.10.6 00:72:78:89:35:F3 255.255.255.0 192.168.10.1 CISCO SF250-24P C-212 C2 admin umesc_608

4 CH SPLITTER BLDG C 92.168.10.12 90:DA:6A:0A:42:5D 255.255.255.0 192.168.10.1 DIGITAL WATCHDOG DW-HDSPOTMOD C-212 admin umesc608

BC-F1-1 BLDG C 192.168.10.30 00:04:7D:41:75:FB 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 8 admin umesc608

BC-F1-2 BLDG C 192.168.10.31 00:04:7D:41:75:FA 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 9 admin umesc608

BC-F1-3 BLDG C 192.168.10.32 00:04:7D:41:75:FC 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 10 admin umesc608

BC-F1-4 BLDG C 192.168.10.33 00:11:35:03:5C:EB 255.255.255.0 192.168.10.1 PELCO EVO-12NJD 2.32 C-212 C1 11 admin umesc608

BC-F1-5x BLDG C 192.168.10.34 00:04:7D:41:71:58 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 C-212 C1 12 admin umesc608

BC-F1-6x BLDG C 192.168.10.47 00:04:7D:41:71:59 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 C-212 C1 4 admin umesc608

BC-F1-7x BLDG C 192.168.10.64 00:04:7D:41:A8:5D 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 C-212 C1 13 admin umesc608

BC-F2-1 BLDG C 192.168.10.35 00:04:7D:41:75:F4 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 14 admin umesc608

BC-F2-2 BLDG C 192.168.10.36 00:04:7D:41:76:04 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 2 admin umesc608

BC-F2-3 BLDG C 192.168.10.37 00:04:7D:41:75:F7 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 15 admin umesc608

BC-F2-4x BLDG C 192.168.10.38 00:04:7D:41:A8:5B 255.255.255.0 192.168.10.1 PELCO IMM12018-1EP 2.13.4.6.8360-A0.0 C-212 C1 16 admin umesc608

BC-F2-5 BLDG C 192.168.10.39 00:04:7D:41:75:C1 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 17 admin umesc608

BC-F2-6 BLDG C 192.168.10.40 00:04:7D:41:75:F5 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 5 admin umesc608

BC-F2-7 BLDG C 192.168.10.41 00:04:7D:41:52:E5 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 C1 18 admin umesc608

BC-F2-8x BLDG C 192.168.10.42 00:04:7D:2A:F3:DF 255.255.255.0 192.168.10.1 PELCO IMM12018-1EP 2.13.4.6.8360-A0.0 C-212 C1 19 admin umesc608

BC-F2-9x BLDG C 192.168.10.43 00:04:7D:41:8E:69 255.255.255.0 192.168.10.1 PELCO IMP531-1ERS 2.32 C-212 C1 3 admin umesc608

NVR BLDG D 192.168.10.2 2C:EA:7F:3E:EE:31 255.255.255.0 192.168.10.1 PELCO VXP-P2-96-6-D D-350b D 24 admin umesc608

D SWITCH BLDG C 192.168.10.7 00:72:78:89:0C:7D 255.255.255.0 192.168.10.1 CISCO SF250-24P D-350b D admin umesc_608

BD-F1-1 BLDG D 192.168.10.44 00:04:7D:41:75:F8 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 5 admin umesc608

BD-F1-2 BLDG D 192.168.10.45 00:04:7D:41:52:E6 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 6 admin umesc608

BD-F1-3 BLDG D 192.168.10.46 00:04:7D:41:75:BE 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 7 admin umesc608

BD-F2-1 BLDG D 192.168.10.48 00:04:7D:41:75:BC 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 8 admin umesc608

BD-F2-2 BLDG D 192.168.10.49 00:04:7D:41:52:E2 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 2 admin umesc608

BD-F2-3 BLDG D 192.168.10.50 00:04:7D:41:75:F6 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 9 admin umesc608

BD-F2-4 BLDG D 192.168.10.51 00:04:7D:41:52:E4 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 10 admin umesc608

BD-F2-5 BLDG D 192.168.10.52 00:04:7D:41:75:F2 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 D-350b D 11 admin umesc608

BD-F2-6X BLDG D 192.168.10.53 00:04:7D:41:70:E1 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 D-350b D 3 admin umesc608

BD-F2-7 BLDG C 192.168.10.65 00:04:7D:41:75:C0 255.255.255.0 192.168.10.1 PELCO IMP531-1IRS 2.32 C-212 D 4 admin umesc608

BG SWITCH HEATED STORAGE 192.168.10.11 00:72:78:89:28:3E 255.255.255.0 192.168.10.1 CISCO SF250-24P G-116 G admin umesc_608

BH-F1-1x HEATED STORAGE 192.168.10.54 00:04:7D:2A:F3:BB 255.255.255.0 192.168.10.1 PELCO IMM12018-1EP 2.13.4.6.8360-A0.0 G-116 G 1 admin umesc608

TB SWITCH TOX BLDG 192.168.10.8 00:72:78:89:25:A3 255.255.255.0 192.168.10.1 CISCO SF250-24P TOX BLDG TS admin umesc_608

TB-F1-1x TOX BLDG 192.168.10.55 00:04:7D:41:71:A3 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 TOX BLDG TS 1 admin umesc608

TB-F1-2x TOX BLDG 192.168.10.56 00:04:7D:41:70:DE 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 TOX BLDG TS 2 admin umesc608

PS SWITCH POND STORAGE 192.168.10.10 00:72:78:89:26:6E 255.255.255.0 192.168.10.1 CISCO SF250-24P POND STORAGE PS admin umesc_608

PS-F1-1x POND STORAGE 192.168.10.57 00:04:7D:41:71:57 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 POND STORAGE PS 1 admin umesc608

PS-F1-2x POND STORAGE 192.168.10.58 00:04:7D:41:71:54 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 POND STORAGE PS 2 admin umesc608

PS-F1-3x POND STORAGE 192.168.10.59 00:04:7dD:2A:F1:4E 255.255.255.0 192.168.10.1 PELCO IMM12018-1EP 2.13.4.6.8360-A0.0 POND STORAGE PS 3 admin umesc608

WH SWITCH WELL HOUSE 2 192.168.10.9 00:72:78:89:2C:6F 255.255.255.0 192.168.10.1 CISCO SF250-24P WELL HOUSE 2 WH2 admin umesc_608

WH-F1-1x WELL HOUSE 2 192.168.10.60 00:04:7D:41:70:DF 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 WELL HOUSE 2 WH2 1 admin umesc608

WH-F1-2x WELL HOUSE 2 192.168.10.61 00:04:7D:41:70:DC 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 WELL HOUSE 2 WH2 2 admin umesc608

VE-F1-1x VEHICLE ENTRANCE 192.168.10.62 00:04:7D:41:70:E0 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 VEHICLE ENTRANCE 1 admin umesc608

VE-F1-2x VEHICLE ENTRANCE 192.168.10.63 00:04:7D:41:71:56 255.255.255.0 192.168.10.1 PELCO IBP531-1ER 2.32 VEHICLE ENTRANCE 2 admin umesc608

APHOST P2P BUILDING B 192.168.10.70 3C:0F:C1:04:47:EE 255.255.255.0 192.168.10.1 KCB WES3 VEHICLE ENTRANCE admin umesc608

CLIENT-DWS VEHICLE ENTRANCE 192.168.10.71 3C:0F:C1:04:47:E2 255.255.255.0 192.168.10.1 KCB WES3 BUILDING B admin umesc608

19" EQUIPMENT CABINET

EXISTING FIBER PANEL

NEW CISCO SF250-24P

PoE NETWORK SWITCH

EXISTING HORIZONTAL

LADDER RACK

NEW PELCO VXP 96TB NVR

EXISTING

NETWORK

EQUIPMENT

NEW APC SMART-UPS X 1000VA

NEW APC SMART-UPS X-SERIES

48V EXTERNAL BATTERY PACK

NEW B040-008-19

KVM CONSOLE

EXISTING VERTICAL

LADDER RACK

CEILING

FINISHED FLOOR

CAT6 CABLE ROUTED TO SECOND

FLOOR CAMERA LOCATIONS

EXISTING SLEEVES

CAT6 CABLE ROUTED TO FIRST

FLOOR CAMERA LOCATIONS

EXISTING SLEEVES BETWEEN FLOORS

EXISTING FIBER BACKBONE CABLE

BETWEEN IT ROOMS D-350b AND C-212

19" EQUIPMENT CABINET

EXISTING FIBER PANEL

NEW CISCO SF250-24P

PoE NETWORK SWITCH

EXISTING

NETWORK

EQUIPMENT

NEW APC SMART-UPS X 1000VA

CEILING

FINISHED FLOOR

CAT6 CABLE ROUTED TO SECOND

FLOOR CAMERA LOCATIONS

EXISTING SLEEVES

EXISTING FIBER BACKBONE CABLE

BETWEEN IT ROOMS

19" EQUIPMENT CABINET

EXISTING FIBER PANEL

NEW CISCO SF250-24P

PoE NETWORK SWITCH

EXISTING

NETWORK

EQUIPMENT

NEW APC SMART-UPS X 1000VA

CEILING

FINISHED FLOOR

ENHANCED CAT6 CABLE ROUTED TO

SECOND FLOOR CAMERA LOCATIONS

EXISTING SLEEVES

EXISTING FIBER BACKBONE CABLE

BETWEEN IT ROOMS B-219 AND C-212

CISCO SF250-24P

PoE NETWORK SWITCH

FINISHED FLOOR

EXISTING UNDERGROUND

CONDUIT

APC BATTERY BACKUP

2' X 2' PLYWOOD BACKBOARD

J-HOOK CABLE SUPPORT SYSTEM

CAT6 CABLE TO CAMERA LOCATIONSCAT6 CABLE TO CAMERA LOCATIONS

CONDUIT STUB UP W/ BUSHING

EXISTING FIBER

ENCLOSURE

EXISTING FIBER BACKBONE

ROUTED TO BUILDING C

IT ROOM C-212

FIBER PATCH CABLE TO NEW CISCO SWITCH

CONDUIT WITH POWER CABLE

TO EXISTING AC OUTLET

EXISTING 120VAC

POWER OUTLET

6U WALL MOUNTED LOCKED

EQUIPMENT ENCLOSURE

1. ALL LOCATIONS SHOWN ARE NOT EXACT

LOCATIONS. ACTUAL MOUNTING HEIGHTS

AND LOCATIONS NEED TO BE FIELD VERIFIED

BEFORE INSTALLATION.

2. ALL EXTERIOR DEVICES WILL REQUIRE AN

EXTERIOR GRADE CAT6 CABLE.

3. ALL EXTERIOR PENETRATIONS ARE TO BE

SEALED WITH CLEAR WEATHERPROOF

SILICON CAULK.

4. TERMINATE EXTERIOR CAT6 CABLE ON DITEK

SURGE PROTECTORS. ROUTE 14AWG

GROUND CABLE TO EXISTING TGB OR TGBM.

5. REPLACE ANY FIRECAULK THAT IS

DISTURBED OR REMOVED FORM EXISTING

SLEEVES.

GENERAL NOTES: scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

CCV EQUIPMENT

DETAILS

T-501

SCALE: AS NOTED

1 AS-BUILT DRAWINGS 11/19/2020

SCALE:

T-401 BUILDING D IT ROOM D-350b EQUIPMENT ELEVATION

1/8" = 1'

SCALE:

T-401

BUILDING C IT ROOM C-212 EQUIPMENT ELEVATION

1/8" = 1'SCALE:

T-401

BUILDING B IT ROOM B-219 EQUIPMENT ELEVATION

1/8" = 1'

SCALE:

T-401

TYPICAL 6U ENCLOSURE ELEVATION

1/8" = 1'

19" EQUIPMENT CABINET

EXISTING FIBER PANEL

NEW CISCO SF250-24P

PoE NETWORK SWITCH

EXISTING HORIZONTAL

LADDER RACK

NEW PELCO VXP 96TB NVR

EXISTING

NETWORK

EQUIPMENT

NEW APC SMART-UPS X 1000VA

NEW APC SMART-UPS X-SERIES

48V EXTERNAL BATTERY PACK

NEW B040-008-19

KVM CONSOLE

EXISTING VERTICAL

LADDER RACK

CEILING

FINISHED FLOOR

CAT6 CABLE ROUTED TO SECOND

FLOOR CAMERA LOCATIONS

EXISTING SLEEVES

CAT6 CABLE ROUTED TO FIRST

FLOOR CAMERA LOCATIONS

EXISTING SLEEVES BETWEEN FLOORS

EXISTING FIBER BACKBONE CABLE

BETWEEN IT ROOMS D-350b AND C-212

19" EQUIPMENT CABINET

EXISTING FIBER PANEL

NEW CISCO SF250-24P

PoE NETWORK SWITCH

EXISTING

NETWORK

EQUIPMENT

NEW APC SMART-UPS X 1000VA

CEILING

FINISHED FLOOR

CAT6 CABLE ROUTED TO SECOND

FLOOR CAMERA LOCATIONS

EXISTING SLEEVES

EXISTING FIBER BACKBONE CABLE

BETWEEN IT ROOMS

19" EQUIPMENT CABINET

EXISTING FIBER PANEL

NEW CISCO SF250-24P

PoE NETWORK SWITCH

EXISTING

NETWORK

EQUIPMENT

NEW APC SMART-UPS X 1000VA

CEILING

FINISHED FLOOR

ENHANCED CAT6 CABLE ROUTED TO

SECOND FLOOR CAMERA LOCATIONS

EXISTING SLEEVES

EXISTING FIBER BACKBONE CABLE

BETWEEN IT ROOMS B-219 AND C-212

CISCO SF250-24P

PoE NETWORK SWITCH

FINISHED FLOOR

EXISTING UNDERGROUND

CONDUIT

APC BATTERY BACKUP

2' X 2' PLYWOOD BACKBOARD

J-HOOK CABLE SUPPORT SYSTEM

CAT6 CABLE TO CAMERA LOCATIONSCAT6 CABLE TO CAMERA LOCATIONS

CONDUIT STUB UP W/ BUSHING

EXISTING FIBER

ENCLOSURE

EXISTING FIBER BACKBONE

ROUTED TO BUILDING C

IT ROOM C-212

FIBER PATCH CABLE TO NEW CISCO SWITCH

CONDUIT WITH POWER CABLE

TO EXISTING AC OUTLET

EXISTING 120VAC

POWER OUTLET

6U WALL MOUNTED LOCKED

EQUIPMENT ENCLOSURE

1. ALL LOCATIONS SHOWN ARE NOT EXACT

LOCATIONS. ACTUAL MOUNTING HEIGHTS

AND LOCATIONS NEED TO BE FIELD VERIFIED

BEFORE INSTALLATION.

2. ALL EXTERIOR DEVICES WILL REQUIRE AN

EXTERIOR GRADE CAT6 CABLE.

3. ALL EXTERIOR PENETRATIONS ARE TO BE

SEALED WITH CLEAR WEATHERPROOF

SILICON CAULK.

4. TERMINATE EXTERIOR CAT6 CABLE ON DITEK

SURGE PROTECTORS. ROUTE 14AWG

GROUND CABLE TO EXISTING TGB OR TGBM.

5. REPLACE ANY FIRECAULK THAT IS

DISTURBED OR REMOVED FORM EXISTING

SLEEVES.

GENERAL NOTES: scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

CCV EQUIPMENT

DETAILS

T-501

SCALE: AS NOTED

1 AS-BUILT DRAWINGS 11/19/2020

SCALE:

T-401 BUILDING D IT ROOM D-350b EQUIPMENT ELEVATION

1/8" = 1'

SCALE:

T-401

BUILDING C IT ROOM C-212 EQUIPMENT ELEVATION

1/8" = 1'SCALE:

T-401

BUILDING B IT ROOM B-219 EQUIPMENT ELEVATION

1/8" = 1'

SCALE:

T-401

TYPICAL 6U ENCLOSURE ELEVATION

1/8" = 1'

1. ALL LOCATIONS SHOWN ARE NOT EXACT

LOCATIONS. ACTUAL MOUNTING HEIGHTS

AND LOCATIONS NEED TO BE FIELD VERIFIED

BEFORE INSTALLATION.

2. ALL EXTERIOR DEVICES WILL REQUIRE AN

EXTERIOR GRADE CAT6 CABLE.

3. ALL EXTERIOR PENETRATIONS ARE TO BE

SEALED WITH CLEAR WEATHERPROOF

SILICON CAULK.

4. TERMINATE CAT6 CABLE ON DITEK SURGE

PROTECTORS. ROUTE 14AWG GROUND

CABLE TO GROUND LUG ON THE BACK OF

THE APC BATTERY BACKUP.

5. ALL CABLES TO BE CABLE SUPPORTED BY

J-HOOKS OR EQUIVALENT APPROVED CABLE

SUPPORT SYSTEM.

GENERAL NOTES: scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

CCV EQUIPMENT

DETAILS

T-501

SCALE: AS NOTED

1 AS-BUILT DRAWINGS 11/19/2020

SCALE:

T-501

INTERIOR CEILING MOUNT DOME CAMERA DETAIL

1:16

(1) CAT6 CABLE ROUTED ABOVE

CEILING TO NEAREST IT CLOSET

J-HOOK CABLE SUPPORT SYSTEM

DROP CEILING

FINISHED FLOOR

PELCO IMP531-1IRS

5MP DOME CAMERA

10' CAT6 SERVICE LOOP

TOGGLEBOLT SUPPORT SCREWS (1) CAT6 CABLE ROUTED ABOVE

CEILING TO NEAREST IT CLOSET

J-HOOK CABLE SUPPORT SYSTEM

DROP CEILING

FINISHED FLOOR

PELCO EVO-12NJD

12MP FISH EYE CAMERA

10' CAT6 SERVICE LOOP

TOGGLEBOLT SUPPORT SCREWS

SCALE:

T-501

INTERIOR CEILING MOUNT FISHEYE CAMERA DETAIL

1:16

(1) CAT6 CABLE ROUTED ABOVE

CEILING TO NEAREST IT CLOSET

J-HOOK CABLE SUPPORT SYSTEM

DROP CEILING

PELCO IBP531-1ER

5MP BULLET CAMERA

10' CAT6 SERVICE LOOP CONDUIT BACKBOX

FINISHED FLOOR

CONDUIT SLEEVE W/ BUSHING

EXISTING STRUCTURE

(1) CAT6 CABLE ROUTED ABOVE

CEILING TO NEAREST IT CLOSET

J-HOOK CABLE SUPPORT SYSTEM

DROP CEILING PELCO IMP531-1IRS

5MP DOME CAMERA

10' CAT6 SERVICE LOOP CONDUIT BACKBOX

FINISHED FLOOR

CONDUIT SLEEVE W/ BUSHING

EXISTING STRUCTURE

PELCO IMP531-1IRS

5MP DOME CAMERA

EXISTING STRUCTURE

PELCO WALL MOUNT

PELCO PENDANT

MOUNT ADPATER

WEATHERPROOF JUNCTION

BOX W/ FLEX CONDUIT

PELCO CORNER MOUNT

SCALE:

T-501

EXTERIOR WALL MOUNT BULLET CAMERA DETAIL

1:16

SCALE:

T-501

EXTERIOR WALL MOUNT DOME CAMERA DETAIL

1:16 SCALE:

T-501

EXTERIOR CORNER MOUNT DOME CAMERA DETAIL

1:16

32" WALL MOUNTED MONITOR

SCALE:

T-501

BUILDING C ROOM C-213 SECURITY MONITORING DETAIL

1:10

HD SPOT MONITOR

HDMI INPUT TO 32" MONITOR

120VAC POWER CABLE

(1) CAT6 CABLE ROUTED

THROUGH WALL TO

ACCESSIBLE CEILING SPACE

10' CAT6 SERVICE LOOP

J-HOOK CABLE SUPPORT SYSTEM

scDataCom

2700 GREGORY ST SUITE 180

SAVANNAH, GA 31405

912-777-5721

CHECKED BY:

DRAWN BY:

DATE:

PROJECT #:

REV DESCRIPTION DATE

THIS DRAWING, AND ALL INFORMATION

CONTAINED HEREIN IS PROPRIETARY AND

IS PROPERTY OF SCDATACOM. ANY USE,

DISSEMINATION OR REPRODUCTION

WITHOUT THE WRITTEN PERMISSION OF

SCDATACOM IS PROHIBITED.

U

PP

ER

M

ID

W

ES

T

EN

VI

R O

N M

EN

TA

L

SC

IE

N

C E

C

EN

TE

R

C C

V U

PG

R

AD

E

F

AN

TA

R

EE

D

R O

AD

LA

C R

O

SS

E, W

I 5

140G0220P0223 07/16/2020

DLM

DLM

CCV RISER

DIAGRAM

T-601

SCALE: NTS

1 AS-BUILT DRAWINGS 11/19/2020

SCALE:

T-601

CCV RISER DIAGRAM

NTS

BUILDING A

IT ROOM A-101

APC BATTERY

BACKUP

CISCO 24 PORT

PoE SWITCH

120VAC POWER

BA-F1-2

BA-F1-2

BUILDING A FIRST

FLOOR CAMERAS

BA-F2-3x

BA-F2-1

BUILDING A SECOND

FLOOR CAMERAS

BA-F2-2

BUILDING A

CAT6 CABLE

BB-F1-1

BB-F1-2

BUILDING B

SECOND

FLOOR CAMERAS

BB-F2-5x

BB-F2-1

BUILDING B FIRST

FLOOR CAMERAS

BB-F2-2

BB-F2-3x

BUILDING B SECOND

FLOOR P2P

BUILDING B

IT ROOM B-219

APC BATTERY

BACKUP

CISCO 24 PORT

PoE SWITCH

120VAC POWER

BUILDING B

FIBER

ENCLOSURE

BUILDING C

IT ROOM C-212

APC BATTERY

BACKUP

CISCO 24 PORT

PoE SWITCH

CAT6

CABLE

BC-F1-1

BC-F1-7x

BUILDING C FIRST

FLOOR CAMERAS

BC-F2-1

BC-F2-2

BUILDING C

BC-F2-3

BC-F2-4x

BC-F2-5

BC-F2-9x

BUILDING C SECOND

FLOOR CAMERAS

BC-F1-6x

BC-F1-5x

BC-F1-4

BC-F1-3

BC-F1-2

BUILDING C

ROOM C-213

32" MONITOR

HD SPOT

MONITOR

APC BATTERY

BACKUP

120VAC POWER CABLE

FIBER

ENCLOSURE

CAT6 CABLE

HDMI CABLE

120VAC POWER CABLE

BUILDING D

IT ROOM D-350b

APC BATTERY

BACKUP

CISCO 24 PORT

PoE SWITCH

CAT6 CABLE BD-F2-1

BUILDING D FIRST

FLOOR CAMERAS

BD-F1-1

BD-F1-2

BUILDING D

BD-F1-3

(2) APC BATTERY

PACK

BUILDING D SECOND

FLOOR CAMERAS

BD-F2-2

BD-F2-3

BD-F2-14

BD-F2-5

BD-F2-6x

KVM

PELCO NVR

TRIPPLITE KVM - PS780 CABLE

120VAC POWER CABLE

FIBER

ENCLOSURE

MM OM1 CAMPUS FIBER

BACKBONE CABLE

LC DUPLEX FIBER CABLE(S)

LC DUPLEX

FIBER CABLE

CAT6 CABLE

CAT6

CABLE

VEHICLE ENTRANCE

POLE

POLE MOUNT ENCLOSURE

NETWORK

SWITCH

VE-F1-1x

VE-F1-2x

VE-F1-3x

VEHICLE

ENTRANCE

P2P

VEHICLE

ENTRANCE

CAMERAS

BUILDING G

IT ROOM G-116

APC BATTERY

BACKUP

CISCO 24 PORT

PoE SWITCH

120VAC POWER

HS-F1-1x

HEATED STORAGE

CAMERA

BUILDING G

FIBER

ENCLOSURE

CAT6 CABLE

LC DUPLEX

FIBER CABLE

6U EQUIPMENT

ENCLOSURE

APC BATTERY

BACKUP

CISCO 24 PORT

PoE SWITCH

120VAC POWER

POND STORGE

FIBER

ENCLOSURE

LC DUPLEX

FIBER CABLE

CAT6

CABLE

PS-F1-2x

PS-F1-1x

POND STORAGE

CAMERAS

6U EQUIPMENT

ENCLOSURE

APC BATTERY

BACKUP

CISCO 24 PORT

PoE SWITCH

120VAC POWER

TOX. BUILDING

FIBER

ENCLOSURE

LC/SC DUPLEX

FIBER CABLE

CAT6

CABLE

TX-F1-2x

TX-F1-1x

TOX BUILDING

CAMERAS

PS-F1-3x

CAT6 CABLE

POINT TO POINT SIGNAL

FIBER

ENCLOSURE

BUILDING C

ROOM C-214

CISCO 24 PORT

PoE SWITCH

WELLHOUSE 2 IDF

APC BATTERY

BACKUP

CISCO 24 PORT

PoE SWITCH

120VAC POWER

WH2-F1-1x

BOAT STORAGE

CAMERA

WELLHOUSE 2

FIBER

ENCLOSURE

CAT6 CABLE

LC DUPLEX

FIBER CABLE

MM OM1 CAMPUS FIBER

BACKBONE CABLE

MM OM1 CAMPUS FIBER

BACKBONE CABLE

MM OM1 CAMPUS FIBER

BACKBONE CABLE

MM OM1 CAMPUS FIBER

BACKBONE CABLE

MM OM1

CAMPUS FIBER

BACKBONE

CABLE

LC DUPLEX FIBER CABLE(S)

TO MM SFP MODULES

EXISTING

UNDERGROUND

CONDUIT

BC-F2-6

BC-F2-7

BC-F2-8x

WH2-F1-2x

LC/SC DUPLEX FIBER CABLE

TO MM SFP MODULES

Pages from Exhibit A _CCTV_Plan
Exhibit A _CCTV_Plan
p2
p3
p4
p5
p6
p7
p8
p9
p10
p11
p12
p13
p14