Main Office Restrooms and contractor parking Plant Storage Seed house
North JCPMC Facility Map
Seedhouse Roof Skylight layout
North
Seed house North and East elevation view
Plant Storage skylight layout and elevation views
Metal Roofing R panel and fastener details
Structure Removal, Steel Frame Loft
Remove loft west half of building
Seed house rolling sheet door and opener
Install rolling sheet door and opener
Plant Storage Building Door Opener
Door Opener and hand chain location Door Opener control station location
Plant Storage Building Structure Removal existing lighting
Plant Storage building LED light layout
First Floor Second Floor
Attach 3 LED lights on East side of building to underside of existing loft framing in pattern and location shown.
Locate switch by entry door Electric Panel
Attached 4 LED lights on East side of building loft to building framing in pattern and location shown.
Locate switch at top and bottom of stairs Attach 4 high bay LED lights on West side of building to framing Locate switch by entry door
Seed house 120 volt convenience outlets and Main disconnect switch
Install 8 inch girt 4 feet above floor as shown.
Install 6 120 volt duplex outlets 5-20R as shown
Circuit breaker panel location. Install new
Main disconnect/safety switch. Remove and install new.
North
Install 2 240 volt 50 amp NEMA 6-50R outlets as shown approximately 4 feet above floor.
Seed house 240 volt outlets
Seed house exhaust fan location
Replace exhaust fan at location shown
Plant Storage building exhaust fan location
Replace exhaust fan at location shown.