PROJECT LOCATION
VICINITY MAP
TRAVEL DIRECTIONS:
SHEET OF
United States Department of Agriculture
Forest Service
INDEX OF SHEETS
SHEET SHEET TITLE DATE
G-01 COVER SHEET 5/21/2019
A-01 SPECIFIC DEMOLITION 5/21/2019
A-02 PLAN VIEW OF ROOF 5/21/2019
A-03 RADIANT EDGE DETAILS 5/21/2019
E-01
GUTTER DOWNSPOUT AND FLOOR
DRAIN DETAILS
5/21/2019
E-02 ELECTRICAL SCHEMATIC 5/21/2019
Head west on I-40 W, use the right lane to take exit 195 for I-17 S toward
AZ-89A S/Phoenix/AZ-89A/Flagstaff, keep right at the fork, follow signs for
I-17 N/AZ-89A N/Flagstaff/Grand Canyon and merge onto I-17 N. Take exit
341 for McConnell Drive.Turn right onto east McConnell Drive. Turn right onto east Pine Knoll Drive. Destination will be on the left.
APPROVED:
STATION ENGINEER
DATE
5/2 1/1
9 1 1:
D
LI
RA
C :\U
SE
RS
\F
MC
AR
TH
UR
\B
OX
\73
F
LA
GS
TA
FF
LA
B\
FY
IC
EM
EL
TS
YS
TE
M\
DR
AW
IN
G
4_
\T
IT
LE
P
AG
E.
DW
G;
SOUTHWEST FORESTRY COMPLEX
FLAGSTAFF ARIZONA
ICE MELT SYSTEM
COLORADO
LARIMER COUNTY
STATION HEADQUARTERS
(S22) ROCKY MTN. RESEARCH STATION
5/22/2019
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
5/2 1/1
9 1 1:
D
LI
RA
C :\U
SE
RS
\F
MC
AR
TH
UR
\B
OX
\73
F
LA
GS
TA
FF
LA
B\
FY
IC
EM
EL
TS
YS
TE
M\
DR
AW
IN
G
4_
\IC
E_
ME
LT
_S
HE
ET
2.
DW
G;
(S22)
ROCKY MTN. RESEASRCH STATION
SOUTHWEST
FORESTRY COMPLEX
FLAGSTAFF ARIZONA
ICE MELT SYSTEM
ROCKY MTN.
RESEARCH STATION
STATION HEADQUARTERS
SPECIFIC DEMOLITION
5/21/2019
*.dwg
D. LIRA
D.LIRA
X.XXX
A-01
006002
REMOVE HEAT TAPE CLIPS
REMOVE HEAT TAPE
NORTH SIDE OF BUILDING
NOTES:
1. DISCONNECT EXISTING HEAT TAPE FROM POWER SOURCE.
2. REMOVE EXISTING HEAT TAPE CONTROLLER INCLUDING ALL SENSORS.
3. REMOVE ALL HEAT TAPE FROM ROOF SURFACE, GUTTERS AND DOWNSPOUTS.
4. REMOVE ALL HEAT TAPE CLIPS FROM GUTTERS, DOWNSPOUTS AND ROOF SURFACE.
5. APPLY ASTM D412 SEALANT TO FASTENER HOES IN GUTTERS AND DOWN SPOUTS.
6. APPLY ASTM D7349 / D7349M TO FASTENER HOLES IN ROOF DECK.
7. FASTENER HOLES WITHIN GUTTERS, DOWNSPOUTS ARE TO BE REUSED IF POSSIBLE IN THE
INSTALLATION OF THE NEW ICE MELT SYSTEM.
8. FASTENER HOLES WITHIN THE ROOF DECK ARE TO BE SEALED AND COVERED WITH THE
INSTALLATION OF THE NEW ICE MELT SYSTEM AND SNOW GUARDS, IF POSSIBLE.
9. CLEAN ALL GUTTERS AND DOWNSPOUTS PRIOR TO INSTALLATION OF NEW ICE MELT SYSTEM.
INSTALL CLIP STYLE SNOW GUARDS AND
FENCE-STYLE SNOW GUARDS AT
LOCATIONS WHERE THE EXISTING
HEATER CABLE CLIPS ARE REMOVED.
TYPICAL HEAT CABLE INSTALLATION ON FIRST ROOF
DECK
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
5/2 1/1
9 1 1:
D
LI
RA
C :\U
SE
RS
\F
MC
AR
TH
UR
\B
OX
\73
F
LA
GS
TA
FF
LA
B\
FY
IC
EM
EL
TS
YS
TE
M\
DR
AW
IN
G
4_
\IC
E_
ME
LT
_S
HH
ET
_3 .D
W G;
(S22)
ROCKY MTN. RESEASRCH STATION
SOUTHWEST
FORESTRY COMPLEX
FLAGSTAFF ARIZONA
ICE MELT SYSTEM
ROCKY MTN.
RESEARCH STATION
STATION HEADQUARTERS
PLAN VIEW OF ROOF
5/21/2019
*.dwg
D. LIRA
D.LIRA
X.XXX
A-02
006003
NORTH
NOTES:
1. INSTALL NEW ICE MELTING SYSTEM IN SHADED AREAS PER MFG. SPECIFICATIONS OVER EXISTING SHINGLED ROOF.
2. REMOVE EXISTING HEATING CABLES IN HATCHED AREA.
3. INSTALL HEAT TAPE IN GUTTERS AND DOWNSPOUTS PER MFG. SPECIFICATIONS.
4. TYPICAL DOWNSPOUT LENGTH IS 45 FEET.
5. INSTALL TWO HEATING CABLES IN GUTTER.
6. INSTALL SINGLE HEATING CABLE IN DOWNSPOUT.
7. HEATING CABLE SHALL BE CONTINUOUS FROM GUTTER TO DOWNSPOUT.
8. HEATING CABLE LENGTH SHALL NOT EXCEED 350 FEET IN LENGTH FOR EACH HEATING ZONE.
9. INSTALL FENCE STYLE 2-RAIL SNOW GUARD PER MFG. SPECIFICATIONS ABOVE RADIANT EDGE ICE MELT SYSTEM.
10. INSTALL 2 ROWS OF SNOW GUARD CLIPS PER MFG. SPECIFICATIONS ABOVE RADIANT EDGE ICE MELT SYSTEM IN AREAS
NOT OCCUPIED WITH FENCE STYLE SNOW FENCE.
11. BUILDING IS SYMMETRICAL.
12. CONTRACTOR TO VERIFY ALL DIMENSIONS.
13. DRAWING IS NOT TO SCALE.
35'
170'
25'
100'
45'
REMOVE HEAT CABLE FROM GUTTER, DOWNSPOUT
AND ROOF
R E
M O
V
X I S
T I N
G
H
E A
T
C A
B L
E
F
R O
M
R
O O
F
65'
SNOW GUARD 2-RAIL
FENCE STYLE
60'
30'
REMOVE HEAT CABLE FROM GUTTER, DOWNSPOUT
AND ROOF
GUTTER
DOWNSPOUT
GUTTER
DOWNSPOUT
A1
A2
A1
A1
BID ITEM # 2-BASE
BID ITEM # 3-BASE
BID ITEM # 4-BASE
A1
A1
BID ITEM ALTERNATE-1
BID ITEM ALTERNATE-2
LEGEND:
PROPOSED UNDER
EVE LOCATION FOR
ELECTRICAL
JUNCTION BOXES
PROPOSED UNDER
EVE LOCATION FOR
ELECTRICAL
JUNCTION BOXES
ICE MELT
SYSTEM
CONTROLLER
ROOM 200
SNOW GUARD 2-RAIL
FENCE STYLE
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
5/2 1/1
9 1 1:
D
LI
RA
C :\U
SE
RS
\F
MC
AR
TH
UR
\B
OX
\73
F
LA
GS
TA
FF
LA
B\
FY
IC
EM
EL
TS
YS
TE
M\
DR
AW
IN
G
4_
\IC
E_
ME
LT
_S
HE
ET
_4 .D
W G;
(S22)
ROCKY MTN. RESEASRCH STATION
SOUTHWEST
FORESTRY COMPLEX
FLAGSTAFF ARIZONA
ICE MELT SYSTEM
ROCKY MTN.
RESEARCH STATION
STATION HEADQUARTERS
RADIANT EDGE
DETAILS
5/21/2019
*.dwg
D. LIRA
D.LIRA
X.XXX
A-03
006004
NOTES:
1. INSTALL BASE PANEL OVER FIRST COURSE OF EXISTING SHINGLES PER MFG. INSTRUCTIONS.
2. TEST HEATER CABLES PRIOR TO INSTALLATION PER MFG. INSTRUCTIONS.
3. INSTALL HEATER CABLES INTO THE UPPER AND LOWER SLOTS.
4. HEATER CABLES ARE NOT TO EXCEED 350 FEET.
5. TEST HEATER CABLES AFTER INSTALLATION INTO THE BASE PLATE SLOTS.
6. INSTALL COVER PER MFG. INSTRUCTIONS.
7. TEST HEATER CABLES AFTER TOP COVER IS INSTALLED BUT BEFORE SEALANT IS APPLIED.
8. SEAL EDGES PER MFG. INSTRUCTIONS.
NOTES:
1. RADIANT EDGE VALLEY IS INSTALLED ON ONE SIDE OF A CLOSED OR WOVEN VALLEY, PREFERABLY THE SIDE WITH LESS
WATERSHED ABOVE.
2. SOUTH SIDE OF BUILDING: INSTALL RADIANT VALLEY ON "EAST" SIDE OF "W" VALLEY FLASHING.
3. NORTH SIDE OF BUILDING: INSTALL RADIANT VALLEY ON "WEST" SIDE OF "W" VALLEY FLASHING.
4. IF NECESSARY, TRIM BACK ADJACENT ROOFING TO ALLOW INSTALLATION.
5. SWEEP VALLEY CLEAN OF ALL DEBRIS AND LOOSE GRANULES.
6. INSTALL VALLEY BASE PANEL ONTO VALLEY USING ADHESIVE PER MFG. INSTRUCTIONS.
7. INSTALL VALLEY BASE PANELS ALL THE WAY DOWN THE VALLEY FLASHING OR BOTTOM OF THE RADIANT EDGE EAVE
PANELS.
8. TEST HEATER CABLES PRIOR TO INSTALLATION PER MFG. INSTRUCTIONS.
9. HEATER CABLES ARE NOT TO EXCEED 350 FEET.
10. INSTALL HEATER CABLES INTO VALLEY BASE PANEL.
11. TEST HEATER CABLES AFTER INSTALLATION PER MFG. INSTALLATION.
12. INSTALL SNAP ON VALLEY PANEL. COVER.
13. TEST HEATER CABLES AFTER PANEL COVER IS INSTALLED.
14. SEAL PER MFG. INSTRUCTIONS.
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
5/2 1/1
9 1 1:
D
LI
RA
C :\U
SE
RS
\F
MC
AR
TH
UR
\B
OX
\73
F
LA
GS
TA
FF
LA
B\
FY
IC
EM
EL
TS
YS
TE
M\
DR
AW
IN
G
4_
\IC
E_
ME
LT
_S
HE
ET
_5 .D
W G;
(S22)
ROCKY MTN. RESEASRCH STATION
SOUTHWEST
FORESTRY COMPLEX
FLAGSTAFF ARIZONA
ICE MELT SYSTEM
ROCKY MTN.
RESEARCH STATION
STATION HEADQUARTERS
GUTTER DOWNSPOUT
AND FLOOR DRAIN
DETAILS
5/21/2019
*.dwg
D. LIRA
D.LIRA
X.XXX
E-01
006005
TYPICAL HEAT CABLE INSTALLATION IN GUTTERS AND DOWNSPOUTS
HEATER CABLE
TEE CONNECTION PER MFG INSTRUCTIONS
TEE CONNECTION PER MFG INSTRUCTIONS
HEATER CABLE
ALLOW 12 INCHES OF HEATER CABLE TO EXIT
DOWNSPOUT AND INSTALL END TERMINATION PER MFG.
INSTRUCTIONS THAN WRAP THE EXCESS BACK ONTO
ITSELF AND SECURE WITH WIRE TIES.
GUTTER
DOWNSPOUT HANGER BEND AT 90
DEGREES AND ATTACH HEATER CABLE
USING PLASTIC TIES PER MFG.
INSTRUCTIONS
DOWNSPOUT HANGER ATTACH HEATER
CABLE USING PLASTIC TIES AND APPLY
ADHESIVE PER MFG. INSTRUCTIONS AND
BOND TO FLOOR OF GUTTER.
NOTES:
1. HEATER CABLE IS NOT TO EXCEED 350 FEET MAXIMUM LENGTH PER HEATING ZONE.
2. SPLICE, TEE CONNECTION AND END TERMINATIONS SHALL BE INSTALLED PER MFG. INSTRUCTIONS.
3. INSTALLATION SHALL USE SEALANTS AND ADHESIVES RECOMMENDED BY MFG.
4. PLASTIC WIRE TIES SHALL BE ULTRA-VIOLET RESISTANT.
5. INSTALLATION SHALL USE MFG. RECOMMENDED SPLICE, POWER AND TERMINATION KITS.
6. TEST HEATER CABLE PRIOR TO INSTALLATION PER MFG. INSTRUCTIONS.
7. TEST HEATER CABLE PER MFG. INSTRUCTIONS AT TEE CONNECTIONS.
8. TEST HEATER CABLE AFTER INSTALLATION PER MFG. INSTRUCTIONS.
9. INSTALL METALLIC RACEWAY TO PROTECT ICE MELT HEATER CABLE PERPENDICULAR TO EXISTING EXTERIOR WALL. AND
ALONG EXTERIOR WALL TO EXISTING OUTLET.
NOTES 10 THROUGH 13 APPLY TO ALTERNATE ITEM #3
10. FLOOR DRAIN HEATING CABLE WILL NOT BE CONNECTED TO THE NEW ICE MELT CONTROLLER.
11. ESTABLISH A 120VAC 20 AMP, GFCI PROTECTED 30 MILLIAMP TRIP RATED CIRCUIT FOR NEW HEATER CABLE.
12. PROVIDE DISCONNECTING MEANS FOR NEW HEATER CABLE THAT IS RESTRICTED ACCESS. PREVENT PUBLIC AND
EMPLOYEES FROM DISCONNECTING.
13. PROVIDE A ELECTRO-MECHANICAL THERMOSTAT FOR ENVIRONMENTAL TEMPERATURE CONTROL. SET POINT FOR
ACTIVATION SHALL BE 32 DEGREES F.
GUTTER
DOWNSPOUT
FLOOR DRAIN FIRST FLOOR
BALCONY
REMOVE EXISTING HEAT CABLE
ALTERNATE ITEM #3
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
5/2 1/1
9 1 1:
D
LI
RA
C :\U
SE
RS
\F
MC
AR
TH
UR
\B
OX
\73
F
LA
GS
TA
FF
LA
B\
FY
IC
EM
EL
TS
YS
TE
M\
DR
AW
IN
G
4_
\IC
E_
ME
LT
_S
HH
ET
_6 .D
W G;
(S22)
ROCKY MTN. RESEASRCH STATION
SOUTHWEST
FORESTRY COMPLEX
FLAGSTAFF ARIZONA
ICE MELT SYSTEM
ROCKY MTN.
RESEARCH STATION
STATION HEADQUARTERS
ELECTRICAL
SCHEMATIC
5/21/2019
*.dwg
D. LIRA
D.LIRA
X.XXX
E-02
006006
TYPICAL CONTROLLER DETAIL
NOTES:
1. ALL WORK PERFORMED SHALL BE PER THE NFPA 70 LATEST EDITION AND THE MFG. INSTRUCTIONS.
2. ALL CONDUCTORS FOR LINE AND LOAD SHALL BE #8 AWG WITH A #10 AWG GROUNDING CONDUCTOR UP TO 200 FEET IN
LENGTH. GREATER THAN 200 FEET IN LENGTH THE CONTRACTOR SHALL CALCULATE THE CONDUCTOR SIZE PER NFPA 70.
3. MAXIMUM VOLTAGE DROP ALLOWED IS 3 PERCENT.
4. ALL HEATER LINE / LOAD CIRCUITS SHALL BE PROTECTED BY A 40 AMP, GFCI BREAKER WITH A 30 MILLIAMP TRIP RATING.
5. CONTRACTOR TO SUPPLY A ICE MELT SYSTEM CONTROLLER WITH A MINIMUM OF 3 SPARE ZONES.
6. MAXIMUM LENGTH OF HEATING CABLE IS 350 FEET PER ZONE.
7. CONTRACTOR TO CALCULATE ALL SUB-PANEL LOAD CALCULATIONS PER NFPA 70 AND SUBMIT AS A SUBMITTAL.
8. THE OUTDOOR TEMPERATURE SENSOR FOR THE CONTROLLER SHALL BE LOCATED ON THE NORTH SIDE OF THE BUILDING.
DO NOT ALLOW ANY SUN ON THE TEMPERATURE SENSOR.
9. THE LINE CIRCUITS CAN BE PROVIDED FROM DIFFERENT SUB-PANELS.
10. CONTRACTOR SHALL MINIMIZE THE LENGTH OF ALL LINE AND LOAD CIRCUITS FROM THE SUB-PANELS TO THE ICE MELTING
SYSTEM CONTROLLER AND FROM THE CONTROLLER TO THE HEATING CABLES.
11. CONTRACTOR SHALL PROVIDE NEMA 3R JUNCTION BOXES ON THE UNDERSIDE OF THE EVES ON THE FIRST ROOF DECK
FOR THE CONNECTIONS FROM THE HEATING CABLE CONDUCTOR TO THE #8 AWG THHN WIRE.
12. CONTRACTOR SHALL REMOVE ALL EXISTING CIRCUITS TO THE EXISTING ICE MELT SYSTEM.
13. CONTRACTOR TO UTILIZE ALL EXISTING CONDUITS AND JUNCTION BOXES OF EXISTING ICE MELT SYSTEM TO EXTERIOR OF
BUILDING IF POSSIBLE.
14. ALL BREAKERS AND CONDUCTORS SHALL BE REMOVED FROM EXISTING ICE MELT SYSTEM. IF THE EXISTING RACEWAYS
ARE NOT USED THEY SHALL BE REMOVED.
15. CAULK ALL PENETRATIONS AS PER THE RATED ASSEMBLIES THAT THE RACEWAYS PASS THROUGH.
16. TEST AND CERTIFY ICE MELT SYSTEM PER MFG. SPECIFICATIONS.
17. LOCATE THE NEW ICE MELT SYSTEM CONTROLLER IN ELECTRICAL ROOM - ROOM 200.
18. PANELS LNU213 AND LNU214 ARE LOCATED IN ROOM 200.
208VAC 40AMP HEATER CABLE ZONE 1
208VAC 40AMP HEATER CABLE ZONE 2
208VAC 40AMP HEATER CABLE ZONE 3
208VAC 40AMP HEATER CABLE ZONE 4
208VAC 40AMP HEATER CABLE ZONE 5
208VAC 40AMP HEATER CABLE ZONE 6
208VAC 40AMP HEATER CABLE ZONE 7 (SPARE)
208VAC 40AMP HEATER CABLE ZONE 8 (SPARE)
208VAC 40AMP HEATER CABLE ZONE 9 (SPARE)
ICE MELT
MULTI-CIRCUIT
ALL-CONTACTOR
DIGITAL
CONTROLLER
208VAC 40AMP LINE ZONE 1
208VAC 40AMP LINE ZONE 2
208VAC 40AMP LINE ZONE 3
208VAC 40AMP LINE ZONE 4
208VAC 40AMP LINE ZONE 5
208VAC 40AMP LINE ZONE 6
208VAC 40AMP LINE ZONE 7 (SPARE)
208VAC 40AMP LINE ZONE 8 (SPARE)
208VAC 40AMP LINE ZONE 9 (SPARE)
120VAC 20AMP LINE CONTROLLER SUPPLY
OUTDOOR TEMPERATURE SENSOR LOCATED ON NORTH SIDE OF BUILDING
DESCRIPTION OF EACH ZONE
1. ZONE 1 - NORTH WEST RADIANT EDGE.
2. ZONE 2 - NORTH WEST GUTTER AND DOWNSPOUT.
3. ZONE 3 - NORTH WEST GUTTER AND DOWN SPOUT.
4. ZONE 4 - NORTH RADIANT EDGE, VALLEY AND GUTTER.
5. ZONE 5 - SOUTH RADIANT EDGE AND VALLEY.
6. ZONE 6 - SOUTH GUTTER AND DOWNSPOUTS
7. ZONE 7 - SPARE
8. ZONE 8 - SPARE
9. ZONE 9 - SPARE
PANEL LNU213 IN ROOM 200
PANEL LNU214 IN ROOM 200
CONTRACTOR SUPPLIED HEATER CABLE ZONES
JUNCTION BOXES ARE LOCATED UNDER THE EVES OF
THE FIRST ROOF DECK.
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
| TITLE PAGE |
| Sheets and Views |
| 17x11 EXPANDED |
| ICE_MELT_SHEET 2 |
| Sheets and Views |
| 17X11 EXPANDED |
| ICE_MELT_SHHET_3 |
| Sheets and Views |
| 17X11 EXPANDED |
| ICE_MELT_SHEET_4 |
| Sheets and Views |
| 17X11 EXPANDED |
| ICE_MELT_SHEET_5 |
| Sheets and Views |
| 17X11 EXPANDED |
| ICE_MELT_SHHET_6 |
| Sheets and Views |
| 17X11 EXPANDED |
File details come from the government source that posted it.