12024B18R9006_Attachment_3_4-30-2018.pdf

PDF 3 MB Posted

Attached to
National Long-Term Fire Retardant
Solicitation number
12024B18R9006
Issued by

About this file

Attach 3

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Region-Bid Item-Agency-Base Previous Contract Prev # Required Delivery Period Retardant Product

CLIN 0001 - Type A Air Tanker Bases (29 Total) A-R1-01-BLM-Billings, MT Full 1 1 June - 15 September LC95A-R (Lot #: 1051695-C) A-R1-02-FS-Helena, MT Full 2 7 July - 19 September LC95A-R (Lot #: 1051695-C) A-R2-01-FS-Durango, CO Full 4 15 May - 29 September LC95A-R (Lot #: 1051695-C) A-R2-02-BLM-Grand Junction, CO Full 3 12 May - 1 October LC95A-R (Lot #: 1051695-C) A-R2-03-FS-Rapid City, SD Full 5 1 June - 30 September LC95A-R (Lot #: 1051695-C) A-R3-01-FS-Albuquerque, NM Full 6 29 April - 16 July MVP-Fx (Lot #: 0403014-A/B) A-R3-02-FS-Ft. Huachuca, AZ Full 10 15 April - 18 July MVP-Fx (Lot #: 0403014-A/B) A-R3-03-FS Phoenix-Mesa Gateway, AZ Full 9 15 April - 31 July LC95A-R (Lot #: 1051695-C) A-R3-04-FS-Prescott, AZ Full 7 1 May - 29 July LC95A-R (Lot #: 1051695-C) A-R3-05-FS-Winslow, AZ Full 8 3 May - 12 July LC95A-R (Lot #: 1051695-C) A-R4-01-BLM-Battle Mountain, NV Full 17 1 June - 30 September LC95A-R (Lot #: 1051695-C) A-R4-02-FS-Boise, ID Full 12 1 June - 30 September LC95A-R (Lot #: 1051695-C) A-R4-03-BLM-Cedar City, UT Full 19 15 May - 30 September LC95A-F (Lot #: 0381045-B) A-R4-04-FS-Hill AFB, UT Full 15 12 June - 12 October LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) A-R4-05-FS-McCall, ID Full 11 28 June - 30 September LC95A-R (Lot #: 1051695-C) A-R4-06-BLM-Pocatello, ID Full 14 23 June - 7 October LC95A-R (Lot #: 1051695-C) A-R4-07-BLM-Stead, NV Full 16 1 June - 30 September LC95A-R (Lot #: 1051695-C) A-R4-08-BLM-Twin Falls, ID Full 13 15 June - 30 September LC95A-R (Lot #: 1051695-C) A-R4-09-BLM-Winnemuca, NV Full 18 1 June - 30 September LC95A-R (Lot #: 1051695-C) A-R5-01-FS-Castle ATB, CA Full 26 1 June - 30 September MVP-Fx (Lot #: 0403014-A/B) A-R5-02-FS-Chester, CA Full 22 15 June - 15 October MVP-Fx (Lot #: 0403014-A/B) A-R5-03-FS-Fox Field (Lancaster), CA Full 25 1 June - 30 November MVP-Fx (Lot #: 0403014-A/B) A-R5-04-FS-Fresno, CA Full 23 23 May - 31 October MVP-Fx (Lot #: 0403014-A/B) A-R5-05-FS-Redding, CA Full 24 1 June - 31 October MVP-Fx (Lot #: 0403014-A/B) A-R5-06-FS-San Bernadino, CA Full 21 29 May - 3 November MVP-Fx (Lot #: 0403014-A/B) A-R5-07-FS-Santa Maria, CA Full 31 15 May - 15 November MVP-Fx (Lot #: 0403014-A/B) A-R6-01-FS-Medford, OR Full 29 1 June - 15 October LC95A-R (Lot #: 1051695-C) A-R6-02-FS-Moses Lake, WA Full 30 10 June - 24 October LC95A-R (Lot #: 1051695-C) A-R6-03-FS-Redmond, OR Full 28 1 June - 15 October LC95A-R (Lot #: 1051695-C)

CLIN 0002 - Type B Air Tanker Bases (42 Total) B-R1-01-FS-Coeur d'Alene, ID Bulk 3 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R1-02-FS-Grangeville, ID Bulk 4 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R1-03-FS-Missoula, MT Bulk 1 N/A MVP-Fx (Lot #: 0403014-A/B) B-R1-04-FS - W. Yellowstone, MT Bulk 2 N/A MVP-Fx (Lot #: 0403014-A/B) B-R2-01-BLM-Canon City, CO Bulk 21 N/A LC95A-FX (Lot #: 0439-076B) B-R2-02-BLM-Casper, WY Bulk 27 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R2-03-BLM-Cortez, CO Bulk 22 N/A LC95A-FX (Lot #: 0439-076B) B-R2-04-BLM-Craig, CO Bulk 24 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R2-05-BLM-Greybull,WY Bulk 28 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R2-06-FS-Jeffco (Denver), CO Bulk 5 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R2-07-BLM-Kremmling, CO Bulk 25 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R2-08-FS-Pueblo, CO Bulk 42 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R2-09-BLM-Rawlins, WY Bulk 26 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R2-10-BLM-Rifle, CO Bulk 23 N/A LC95A-FX (Lot #: 0439-076B) B-R3-01-FS-Alamogordo, NM Bulk 8 N/A MVP-Fx (Lot #: 0403014-A/B) B-R3-02-BLM-Roswell, NM Bulk 6 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R3-03-BLM-Safford, AZ Bulk 32 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R3-04-BIA-Show Low, AZ Bulk N/A N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R3-05-FS-Silver City, NM Bulk 7 N/A MVP-Fx (Lot #: 0403014-A/B) B-R4-01-BLM-Fillmore, UT Bulk 35 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R4-02-BLM-Jean, NV Bulk 39 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R4-03-BLM-McDermitt, NV Bulk 36 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R4-04-BLM-Mesquite, NV Bulk 40 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R4-05-BLM-Mountain Home, ID Bulk 41 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R4-06-BLM-Nephi, UT Bulk 34 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R4-07-BLM-Panaca, NV Bulk 38 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R4-08-BLM-Tooele, UT Bulk 33 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R4-09-BLM-Wells, NV Bulk 37 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R5-01-FS-Bishop, CA Bulk 10 N/A MVP-Fx (Lot #: 0403014 A/B) B-R5-02-FS-Montague, CA Bulk 12 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R5-03-FS-Porterville, CA Bulk 11 N/A MVP-Fx (Lot #: 0403014-A/B) B-R6-01-BLM-Burns, OR Bulk 30 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R6-02-FS-John Day, OR Bulk 16 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R6-03-FS-Klamath Falls, OR Full 27 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R6-04-FS-La Grande, OR Bulk 14 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R6-05-BLM-Lakeview, OR Bulk 31 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R6-06-BIA-Omak, WA Bulk 13 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R6-07-BLM-Ontario, OR Bulk 29 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) B-R8-01-FS-Chattanooga, TN Bulk 18 N/A MVP-Fx (Lot #: 0403014-A/B) B-R8-02-FS-Fayetteville, AR Bulk 17 N/A MVP-Fx (Lot #: 0403014-A/B) B-R8-03-FS-Lake City, FL Bulk 19 N/A MVP-Fx (Lot #: 0403014-A/B) B-R10-01-BLM-Ft. Wainright, AK Bulk 20 N/A LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C)

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service National Office

J-1 - 1

A-R01-01-BLM-Billings, MT Required Delivery Period 1 June - 15 September VLATs No Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 98,000 gal SEATs Yes Pits 2 MAFFS Yes Simultaneous Pits 2 Offload Capacity 5,000 gal Water Supply BLM hydrant for water supply w/ 5,000 gal water tank Electrical Supply Stand alone electric panel 240/208 volt suppling mix plant operations, loading pits, sheds, and multipl

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 5,000 gal continuous flow water supply tank N/A N/A N/A N/A N/A 3 10,000 gal LC concentrate retardant storage tanks N/A N/A N/A N/A N/A 1 5,000 gal offload/premix tank N/A N/A N/A N/A N/A 1 1,500 gallon poly tank with recirc system N/A N/A N/A N/A N/A 1 Lot, numerous fittings and hose size 2" N/A N/A N/A N/A N/A 1 Lot, Misc tools, wrenches N/A N/A N/A N/A N/A 1 Forklift N/A N/A N/A N/A N/A 2 Mass Flow System N/A N/A N/A N/A N/A 2 Trailers (1) contractor, (1) pilot crew N/A N/A N/A N/A N/A 2 Pumps for evaporation pond N/A N/A N/A N/A N/A 3 Storage sheds for retardant storage N/A N/A N/A N/A N/A 1 Lot, catwalks across tanks N/A N/A N/A N/A N/A

Notes:

No property numbers on any storage tanks.

Cat walk across the top of all tanks.

Printers: Pit 1- S/N 12022265 Model no. DS300S155SU. Pit 2- S/N 12022116 model no. DS300S155SU Trailers: 1 for retardant contractor, 1 for pilot crew rest .

Pipe wrenches: 1 ea 48", 2 ea 36", 1 ea 18".

Must be able to maintain simultaneous retardant loading both pits 1 and 2.

Minimum 400 to 500 GPM utilizing electric pumps with capability to switch pump speed down to load SEATs, along with a back-up gas pump if there is a electric power Ability to continue to monitor and control loading operations remotely at each pit simultaneously. Utilizing wireless remote loading system

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Billings Gorman Rupp 14A2 Marathon CAT 438 Recirc./Off-Load Pum001898 Billings Loading Skates Aluminium Billings Water Meter 4" with Head Micrometer 001892 Billings Wacker PTS4 Briggs & Stratton Vanguard 001362 Billings Wacker PTS4 Briggs & Stratton Vanguard 001985 Billings Blender Canadian 002610 Billings Blender Canadian 002612 Billings MCM 250X Kohler 40HP - CH100 002608 Billings MCM 250X Crown Triton 002609 Billings Variable Speed Elect. Control Mod. 002613 Billings MCM 250X Crown Triton 002611 Billings OSHA Stairs Billings Shade Canopy Billings Shade Canopy

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 2

A-R01-02 FS Helena, MT Required Delivery Period 7 July - 19 September VLATs No Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 70,000 gal SEATs Yes Pits 2 MAFFS Yes Simultaneous Pits 1 Offload Capacity 6,000 gal Water Supply Municipal supply through six inch service, flowing at 500 gpm Electrical Supply 3 phase, 480 volt, 4 wire, 600 amp power panel is located in the plant area.

Storage Small indoor over-winter storage available.

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 20,000 gal water tank N/A N/A N/A N/A N/A 1 Mass Flow System MicroMotion N/A N/A #AG0001655117 Excellent 1 Lot, office space for contractor N/A N/A N/A N/A N/A 1 Lot, warehouse and covered storage for retardant N/A N/A N/A N/A N/A

Notes:

Other Base Needs: Min capacity of 3,000 gal off load tank. 4-50' loading hoses. 1 loading pump, 400 gpm min 500 gpm max. 1 back-up loading pump. 1 off load pump.

The contractor shall be responsible for all conduit, boxes, panels, switching and wiring not already in this panel, as well as the cost.

All equipment at the Helena Tanker Base is 12 years old. Serial # 2446289, The water manifold from the water tank to the edge of pit is FS owned.

The manifold to both pits after the micro motion is FS owned. The under ground water valves are starting to get hard to turn.

*Daily Peak Demand confirmed with ATBM- Jeffrey Jackson

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Helena Deming 3M Marathon 1F284TTFC8026AAS Load Pump 1 001897 Helena Wacker PTS4V Vanguard 305447 Premix Tank Pump 001434 Helena Gorman Rupp 14A2 Baldor M2334T Recirc. Pump 1 002119 Helena Deming 4M Wisconsin V46501 Backup 001899 Helena Gorman Rupp 13D-1 Briggs & Stratton 980925YD Off-Load Pump 3" 001900 Helena Tank Retardant 1 10K steel Helena Tank Retardant 2 10K steel Helena Tank Retardant 3 10K steel

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 3

A-R02-01 FS Durango, CO Required Delivery Period 15 May - 29 September VLATs No Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 45,000 gal SEATs Yes Pits 2 MAFFS Yes Simultaneous Pits 1 Offload Capacity 6,500 gal Water Supply Contractor will need to haul water to the Base for retardant mixing and wash down.

Electrical Supply Agency supplied 3 phase, 227/480 volt, 400 amp. Contractor provide wiring from panel.

Electric meter for mix plant needs to be in contractors name during contract period.

Storage LC storage available. Dry powder storage limited. Room for uncovered expansion.

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

4 10,000 gal retardant tank N/A N/A N/A N/A 1-3 very good, 4?

2 20,000 gal water tank N/A N/A N/A N/A very good 1 7,500 gal off-load tank N/A N/A N/A N/A N/A 1 Mass Flow System MicroMotion N/A CMF300M355N2BAE14254941 Excellent (2011) 1 Mass Flow System MicroMotion N/A 3700A1A05DAEZZX 2503224 Excellent (2015) 1 Electric delivery pump Gorman Rupp T4A60-B M4115T 1216882 Good 1 Gas load delivery pump Gorman Rupp VH4D1/Wisconsin 463636 1120011 Old 1 Gas recirculation delivery pump Gorman Rupp VH4D1/Wisconsin 463636 1120012 Old 1 Offload pump Honda WT30X N/A N/A old 1 Jacuzzi Pump for wash down Jacuzzi 3VB650-4-S2 N/A N/A Good 1 119 gal pre-charged tank for Jacuzzi pump N/A 4P839 N/A N/A N/A 1 Lot, limited dry powder storage N/A N/A N/A N/A N/A

Notes:

Contractor provides plumbing and fittings to match existing configuration that allow for mixing and other operations.

Contractor arranges yearly clean out of sand-oil separator.

The Jacuzzi Pump is required to charge wash down lines on pads 1 & 2. Water source is from the (2) 20,000 gal. water tanks. (Special Note: This water is paid for and shipped Recirc pump should be replaced with an electric pump. Delivery pump should be a 400 - 500 GPM and load SEATS. Require flow switch to drop to idle when port valves are sh ConnexLink 4490 Transmitter by Laird Technologies. Used to send data to Micro Motion Printer. Condition Excellent. 2 years old Thermal Printer by Westrex International, Model # 800, Serial # 8515A00235. Condition Very Good. At least 6 years old Manifold. Condition, Very Good. 12 years old - Joints/valves replaced in 2016 with seismic design replacement

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Durango Blender Valve Canadian first gen none Durango Air Compressor

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 4

A-R02-02 BLM Grand Junction, CO Required Delivery Period 12 May - 1 October VLATs No Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 100,000 gal SEATs Yes Pits 2 MAFFS Yes Simultaneous Pits 2 Offload Capacity 5,000 gal Water Supply Agency supplied water from hydrant off 8" line.

Electrical Supply Agency supplied 3 phase, 400 amp. Contractor supplies all elec. components & expertise.

Storage Storage area for dry powder is limited.

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 5,000 gal off-load tank N/A N/A N/A N/A Fair 2 Mass Flow System MicroMotion N/A N/A N/A N/A 1 Forklift N/A N/A N/A N/A N/A 1 Lot, warehouse and covered storage for retardant N/A N/A N/A N/A N/A

Notes:

An off load tank is NOT required Contractor supplies all elec. components from panel. 2- 3 phase pumps can be operated simultaneously from panel.

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Grand Junc Deming 407100400 Marathon 4VK28TTC802CABS Load Pump 1 001488 Grand Junc Deming 402104710400 Marathon 3AV28TTFC802GABS Load Pump 2 001149 Grand Junc Gorman Rupp 14A2 Marathon 1H2844TTFC802GAARecirc Pump 1 001152/2131 Grand Junc Gorman Rupp 14A2 na NA Recirc. Pump 2 001911 Grand Junc Gorman Rupp 54A2 Wisconsin VF4D Backup Grand Junc Gorman Rupp 13D-1 Briggs & Stratton 192432 Off-Load Pump 001151 Grand Junc Tank Retardant 1 12K steel 1155 Grand Junc Tank Retardant 2 12K steel 1154 Grand Junc Tank retardant 3 12K steel 1153 Grand Junc Tank Retardant 4 5K steel Off Load *1161 Grand Junc Tank Water 10K steel 1156 Grand Junc Check Valve Nibco none Grand Junc Check Valve Nibco Grand Junc Check Valve Nibco Grand Junc Check Valve Nibco Grand Junc Blender Orifice 1767 Grand Junc Blender Orifice 1770 Grand Junc Square D Control Pannel none Grand Junc Square D Control Pannel none Grand Junc Riverside Pump Backup 002695 Grand Junc Electric Panel CP 0009 Grand Junc Electric Panel CP 0007 Grand Junc Electric Panel CP 0008 Grand Junc Air Compressor Husky 30 Gal, 135 PSI Husky Pro 2 HP Air Compressor

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 5

A-R02-03 FS Rapid City, SD Required Delivery Period 1 June - 30 September VLATs No Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 55,000 gal SEATs Yes Pits 1 MAFFS Yes Simultaneous Pits 1 Offload Capacity 5,000 gal Water Supply Municipal supply through six inch service, flowing through a hydrant at 600 gpm Electrical Supply Agency supplied 3 phase 200 amp panel.

Storage 20 x 40 workshop. 8 x 40 shipping container dry cold storage.

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 10,000 gal water tank N/A N/A N/A N/A N/A 2 15,000 gal retardant tank N/A N/A N/A N/A N/A 1 6,000 gal off-load tank N/A N/A N/A N/A N/A 1 Gorman Rupp gas operated pump (back-up) N/A N/A N/A #1093111 N/A - 2001 1 Mass Flow System MicroMotion N/A N/A #14296435 N/A - 2014 1 Mass Flow System MicroMotion N/A N/A #7123554 N/A 1 Lot, Misc fittings and valves N/A N/A N/A N/A N/A 1 Work shop (20 x 40) N/A N/A N/A N/A N/A 1 Con-Ex (8 x 40) retardant storage N/A N/A N/A N/A N/A

Notes:

Contractor supplies all electrical components and expertise for the required mixing and loading from provided panel to pumps and mixers.

3- phase electrical pumps required 2ea 3 phase may be operated at the same time from the panel.

Minimum capacity of 3,000 gal off- load tank; 4-50' loading hoses; 1-loading pump 400 gpm min 500 gpm max; 1-back-up loading pump; 1-off-load pump Daily Peak Demand confirmed with ATBM – Gordon Schafer

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Rapid City Gorman Rupp 14A2 Weg 02018ep3e256t Load Pump 1 001423 Rapid City Gorman Rupp 14A2 Weg 02018ep3e256t Recirc. Pump 1 001422 Rapid City HONDA WT40X HONDA GX340 Off-Load Pump 000122 Rapid City Blender Y Blender 000437 Rapid City Rock Trap Phos-Chek Design 000514

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 6

A-R03-01 FS Albuquerque, NM Required Delivery Period 29 April - 16 July VLATs No Product MVP-Fx (Lot #: 0403014-A/B) LATs Yes Daily Peak Req 100,000 gal SEATs Yes Pits 2 MAFFS Yes Simultaneous Pits 1 Offload Capacity 4,000 gal Water Supply Municipal supply through six inch service, flowing at 500 gpm Electrical Supply 3 phase, 480 volt, 4 wire, 600 amp power panel is located in the plant area Storage No indoor, over-winter storage

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 Mass Flow System MicroMotion N/A N/A #AG0001229364 N/A - 2014 1 Fenced storage area (portion of 50 x 100) N/A N/A N/A N/A N/A

Notes:

The contractor shall be responsible for all conduit, boxes, panels, switching and wiring not already in this panel, as well as the cost 3- phase electrical pumps required 2ea 3 phase may be operated at the same time from the panel.

7,000 gallon water holding tank for washdown of spills & aircraft is available.

Contractor is responsible for above ground plumbing from on-site water source to supply and mix tanks.

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

AlbuquerquDeming 4021 Siemens-Allis N/A Load Pump 1 002147 AlbuquerquPaco N/A Baldor N/A Water Pump 000737 AlbuquerquGorman Rupp 14A2 Electrim S9 Recirc Pump 002146 AlbuquerquGorman Rupp 14C2 Wisconsin backup 002153 AlbuquerquTank Off-load 4K steel AlbuquerquTank Off-load 6K steel AlbuquerquTank Water 10K steel Water Tank AlbuquerquTank Retardant 1 10K steel AlbuquerquTank Retardant 2 10K steel AlbuquerquTank Retardant 4 10K steel AlbuquerquValve Electric 2.5 inch Water AlbuquerquDollies x 29 AlbuquerquEductor 350 GPM AlbuquerquAir Blower Electric AlbuquerquAir Blower Gas AlbuquerquForklift V50D Caterpillar 000408 AlbuquerquElectrical Panel 200 Amp 000736 AlbuquerquWater Meter 4'' Flanged McCrometer 002173 Albuquerqu* Blender Canadian 002106 AlbuquerquMCM 250X Wisconsin V465D 002250 AlbuquerquTrash Pumps

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 7

A-R03-02 FS Ft. Huachuca Required Delivery Period 15 April - 18 July VLATs No Product MVP-Fx (Lot #: 0403014-A/B) LATs Yes Daily Peak Req 100,000 gal SEATs Yes Pits 3 MAFFS No Simultaneous Pits 1 Offload Capacity 3,000 gal Water Supply Agency/Military supplied. Water from 6” water main flowing at 1400gpm.

Electrical Supply Agency/Military supplied 277/480 volt 600 amp available Storage Sufficient for supplies and leftover product

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 Mass Flow System MicroMotion N/A N/A #246949 N/A + 12 years 1 Mass Flow System MicroMotion N/A N/A #232841 N/A + 15 years 1 Forklift N/A N/A N/A N/A N/A 1 Storage ares sufficient for supplies and product N/A N/A N/A N/A N/A

Notes:

Contractor to furnish 4,000 + gallon off load tank w/capability to off load any airtanker. Contractor is responsible for its plumbing and electrical Daily Peak Demand confirmed with ATBM - Gilbert Gil

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Fort Huach Air Blowers Baldor L3506 for parts 002135 Fort Huach Gorman Rupp 84A2 Deutz Diesel D-914-L03 Load Pump 1 N/A Fort Huach Sulzer 2881 Baldor JMM4108T Water Pump 00731 Fort Huach Air Blower Leeson Electric SPARE 001938 Fort Huach Air Blower A.O. Smith electric SPARE 001920 Fort Huach Poly Tank 3K Poly Tank Snyder Offload Tank 002515 Fort Huach Forklift Toyota 7FGU25 propane NA Fort Huach Pump 13D-1 GX 240 Honda gx 240 off load pump 001353 Fort Huach Pump 14D-1 GX390 honda gx 390 transfer pump 001776 Fort Huach Blower Briggs Stratton back up blower NA Fort Huach Blower Baldor L3506 Main blower 001939 Fort Huach Eductor 00580 Fort Huach Water Meter McCrometer 002171 Fort Huach Water Pump 4PETSO Wisconsin VG4D NA Fort Huach Pump Monarch 5BSGF NA Fort Huach Gorman Rupp 14A2B No motor 001923 Fort Huach Hopper / Dust Collector NA Fort Huach 10 K Retardant Tank 1703 Fort Huach 18 K Retardant Tank 0581

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 8

A-R03-03 FS Phoenix - Mesa, AZ Required Delivery Period 15 April - 31 July VLATs *Yes Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 133,000 gal SEATs Yes Pits 2 + 2 Seats MAFFS Yes Simultaneous Pits 2 Offload Capacity 20,000 gal Water Supply Municipal 2 - 2" supply lines Electrical Supply 3-240/480V hook ups. 110 outlets both main pits.

Storage Office area & 300 Square ft of storage

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 19,800 gal off-load tank N/A N/A N/A N/A N/A 1 Forklift N/A N/A N/A N/A N/A 1 Mass Flow System MicroMotion N/A N/A #14243545 N/A + 3 years 1 Mass Flow System MicroMotion N/A N/A #14244589 N/A + 3 years 1 Office and storage space available N/A N/A N/A N/A N/A

Notes:

*VLAT - DC10 primary, 747 most likely loaded on a separate ramp using MRB Daily Peak Demand confirmed with ATBM

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Phoenix Me Gorman Rupp 14A2 World Energy B0204FLF2UK Spare PF 002122 Phoenix Me Gorman Rupp U46B60-B U.S. Electric Motor R068A Load Pump 1 002506 Phoenix Me Tank Water 10K steel NA Phoenix Me Tank Retardant 12K steel 001203 Phoenix Me Tank Retardant 12K steel 001204 Phoenix Me Clay Valve 4" INLET\OUTLET 4 124-01A Water 001200 Phoenix Me Gorman Rupp 84A2-B Marathon Recirc. Pump 1 001960 Phoenix Me Gorman Rupp U4B60-B US Electric R068A 002507 Phoenix Me Gorman Rupp 14A2 Weg 002122 Phoenix Me Gorman Rupp 13D-1 Honda GX240 001354 Phoenix Me Tank Off-load 10K steel 002573 Phoenix Me Wacker PTS4V Briggs & Stratton 16 HP Off-Load Pump 000745 / 001205 Phoenix Me Air Compressor Craftsman none

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 9

A-R03-04 FS Prescott, AZ Required Delivery Period 1 May - 29 July VLATs No Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 75,000 gal SEATs Yes Pits 3 MAFFS Yes Simultaneous Pits 2 Offload Capacity 5,000 gal Water Supply Agency provided through a 4” municipal water main.

Electrical Supply 400 Amp; 480 Volt. Power (gas, electricity, etc.) supplied/ maintained by the Contractor Storage Office area (160 sq. ft.) & outdoor storage shed (14.5’ x 10.5’) for the contractor’s use

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 Retardant manifolds to 3 pits N/A N/A N/A N/A N/A 1 Lot, wash down hoses N/A N/A N/A N/A N/A 1 Mass Flow System MicroMotion N/A N/A #12005377 N/A 1 Mass Flow System MicroMotion N/A N/A N/A N/A 1 Office and storage available N/A N/A N/A N/A N/A

Notes:

The Contractor provides power supply to pumps, 5000 gallon off-load tank, loading hose, with skates, fittings, valves Contractor shall provide their own phone and internet connection.

Drains lead to a diverter box from containment area to direct runoff to the rubber-lined lagoon or to the landscape.

It is the responsibility of the contractor to ensure spills or runoff is diverted to the lagoon during any tank work/ maintenance outside of the MAP.

Fire extinguisher(s) by the contractor’s pumps/tanks/shed & office area must be serviced/maintained by the vendor.

Loading hose required to reach a MAFFS aircraft parked with the loading valve on the opposite side of the retardant manifold.

Retardant lines must be drained prior to the start of the MAP annually. The retardant manifolds have dual containment and were installed in the fall of 2015.

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Prescott Tank 5K steel Off-Load Prescott Tank 5K steel Water Prescott Tank Retardant 10K steel Prescott Tank Retardant 10K steel Prescott Tank Retardant 10K steel Prescott Electrical Panels 90Amp 480 V Prescott Electrical Panels 60 AMP 480 V Prescott Dollies/Skates 18 steel Prescott Deming 4M Marathon Load Pump 1 001948 Prescott Gorman Rupp 13D-19 Briggs & Stratton 199432 Off-Load Pump Prescott Gorman Rupp 14A2 U.S. Electric Recirc. Pump 1 001165 Prescott Deming 4M Wisconsin V465D Backup 001168\001169 Prescott Cutler Hammer Control Pannel Prescott Blender Orifice Prescott Check Valve Nibco Prescott Check Valve Nibco Prescott Homelite TP4V Briggs & Stratton 10 series/190432 002628 Prescott Skates / Dollies 10 + 6 Quantity Aluminum Prescott Riverside Pump TP4V Briggs & Stratton Off Load Pump 002626 Prescott Craftsman BTM56RB34D2M 150 psi Air Compressor none

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 10

A-R03-05 FS Winslow, AZ Required Delivery Period 3 May - 12 July VLATs No Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 100,000 gal SEATs Yes Pits 3 MAFFS No Simultaneous Pits 1 Offload Capacity 3,000 gal Water Supply Municipal supply through six inch service, flowing at 500 gpm Electrical Supply 3 phase, 480 volt, 4 wire, 600 amp power panel is located in the plant area Storage No indoor over-winter storage available. Office/ Restroom and 10x12 storage shed available

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 5,850 gal water tank N/A N/A N/A N/A N/A 1 9,700 gal retardant tank N/A N/A N/A N/A N/A 1 Mass Flow System MicroMotion N/A N/A #12042206 N/A - 6 yrs 1 Manifold N/A N/A N/A N/A N/A 1 Office and storage shed (no long-term product storage) N/A N/A N/A N/A N/A

Notes:

The contractor shall be responsible for all conduit, boxes, panels, switching and wiring not already in this panel, as well as the cost Minimum capacity of 3,000 gal off load tank. 4-50' loading hoses. 1 loading pump, 400 gpm min 500 gpm max. 1 back-up loading pump. 1 off load pump *Daily Peak Demand confirmed with ATBM

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Winslow Tank Retardant 10K steel water Winslow Gorman Rupp 14-C2B HOSTILE ELEC Recirc. Pump 1 001947 Winslow Deming 3M Wisconsin VG4D Backup FT-GE0051 Winslow Deming 3M Hostile elec. FT EM0029 Load Pump 1 FT EM0079 Winslow Gorman Rupp 14C2-B Hostile elec. PC 1704 Recirc. Pump 2 FT#EM0030 Winslow Deming Wisconsin PT5871 Backup FTPP0082 Winslow Gorman Rupp Off-Load Pump FT PU0081 Winslow Tank Retardant 10K steel Tank # 2 FT ST0084 Winslow Tank Retardant 10K steel Tank #1 FT ST0083 Winslow Blender Orifice Winslow Check Valve Nibco Winslow Check Valve NIBCO Winslow Disconnect Pannel Cutler Hammer Winslow Disconnect Pannel Cutler Hammer Winslow Cutler Hammer Control Pannel Winslow Cutler Hammer Control Pannel Winslow Tank Retardant 10K steel Tank #3 FT ST0085 Winslow Tank 3k Steel Off-Load FT ST0086 Winslow Air Compressor 921 Craftsman 150 psi Compressor none Winslow Water Boost Pump Baldor JML 1409 none Winslow Pump MCM 250X 002840

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 11

A-R04-01 BLM Battle Mtn, NV

Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 105,000 gal SEATs Yes Pits 2 MAFFS Yes Simultaneous Pits 2 Offload Capacity 5,000 gal Water Supply Agency well, two-inch service, flowing at 300 gpm Electrical Supply 400 amp; 3- phase, 220 v Storage Space for dry powder storage & mixing operations is limited.

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 Mass Flow System MicroMotion N/A N/A N/A N/A 1 Office space is available N/A N/A N/A N/A N/A 1 Storage space is limited N/A N/A N/A N/A N/A

Notes:

The contractor has been responsible for all conduit, boxes, panels, switching and wiring not already in these panels, this includes associated costs Office/workshop avail. for contractor’s use.

Water storage capacity of 20,000 gallons min to be furnished by contractor for a total of 30,000 gals of water storage.

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Battle Mou Gorman Rupp 14A2 Weg 02018ep3e256t Load Pump 1 001271 Battle Mou Paco 2882/310561 Baldor N/A Load Pump 2 002161 Battle Mou Gorman Rupp 14C2 Wisconsin VH4D Backup Recirc 001896 Battle Mou Gorman Rupp 13A2-AENLD Wisconsin AENLD Off-Load Pump 001787 Battle Mou Gorman Rupp 53H2 Wisconsin VH4G 000158 Battle Mou Wacker PTS4 Seat/Off load pump none Battle Mou Water Tank 1 12k water tank 1656 Battle Mou Water Tank 2 12k water tank 1657 Battle Mou LC Tank 1 10k LC Tank 1658 Battle Mou LC Tank 2 10k LC Tank 1659 Battle Mou LC Tank 3 10k LC Tank 1660 Battle Mou Off Load Tank 4.5k Off Load Tank none Battle Mou Air Compressor Husky 947265 none Battle Mou Water Boost Pump Baldor G & L SSV Water Boost Pump none Battle Mou Gorman Rupp 14A2-B none

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 12

A-R04-02 FS Boise, ID

Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 96,000 gal SEATs Yes Pits 3 MAFFS Yes Simultaneous Pits 1 Offload Capacity 3,000 gal Water Supply Municipal supply through 5 inch service, flowing at 400-500 gpm.

Electrical Supply Agency provided 400 amp 220 volt electrical.

Storage 1000 sq. ft. of covered storage is available

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 Manifold N/A N/A N/A N/A N/A 3 Lot, loading hoses and skates N/A N/A N/A N/A N/A 1 Mass Flow System MicroMotion N/A N/A #AG0001337946 N/A 2014 1 Office and storage space is limited N/A N/A N/A N/A N/A

Notes:

Contractor shall provide own phone. Contractor responsible for their plumbing & wiring.

1,000 sq ft of covered, paved storage is available.

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Boise Gorman Rupp 53H2 Wisconsin VH4D Gas Backup 000163 Boise Paco 3749601G Baldor 310581 Load Pump 002137 Boise Gorman Rupp 14A2 Weg 02018ep3e256t Recirc. Pump 1 002127 Boise Homelite TP3B Briggs & Stratton J1940 Off-Load Pump 002107 Boise Backflow Preventer Water Zurn Backflow 002600 Boise Water Tank 12k tank 002514 Boise Blender Canadian 2640 Boise Wacker PTS4 2672 Boise Gorman Rupp 13D GX 270 2596 Boise Water Boost Pump none Boise LC Tank 20k steel LC tank

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 13

A-R04-03 BLM Cedar City, UT Required Delivery Period 15 May - 30 September VLATs No Product LC95A-F (Lot #: 0381045-B) LATs Yes Daily Peak Req 35,000 gal SEATs Yes Pits 3 MAFFS Yes Simultaneous Pits 2 Offload Capacity 5,000 gal Water Supply Municipal, four inch supply, flowing at 400 gpm Electrical Supply 110 V, 220 V, 277/480 V Storage N/A

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

2 Mass Flow System MicroMotion N/A N/A N/A N/A 2 10,000 gal Water tanks N/A N/A N/A N/A N/A 3 10,000 gal retardant tanks N/A N/A N/A N/A N/A 1 4,000 gal off-load tank - poly N/A N/A N/A N/A N/A

Notes:

8,000 gal water storage tank to fit within existing spill containment - contractor.

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Cedar City Gorman Rupp U4A60-B Toshiba B0204FLF2UM Load Pump 1 Cedar City Gorman Rupp U4A60-B Toshiba B0204FLF2UM Load Pump 2 Cedar City Gorman Rupp 16C2b Teco Westinghouse AEEANE Recirc. Pump 1 Cedar City Gorman Rupp 14A2 Wisconsin VH4D Backup Cedar City Homelite 51457A Homelite 195432 Off-Load Pump Cedar City Tank Water 8k steel Cedar City Blender Valve Blender Cedar City Blender Valve Blenders Cedar City Offload Tank 3k tank Cedar City 10 k LC Tank Cedar City Air Compressor VT 631 Marathon 30 Gallon Compressor none Cedar City Pump Probably Gorman Rupp Cedar City Pump 13D-GX 270 PC 2509

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 14

A-R04-04 FS Hill AFB, UT Required Delivery Period 12 June - 12 October VLATs No Product LC95A-FX (Lot #: 0439-076B) / LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 61,000 gal SEATs Yes Pits 2 MAFFS Yes Simultaneous Pits 2 Offload Capacity 4,000 gal Water Supply Municipal water supply available Electrical Supply Agency supplied power – 3 phase, 200 amp Storage None

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 Mass Flow System MicroMotion N/A N/A #14196955 N/A 2014 1 Mass Flow System MicroMotion N/A N/A #14196957 N/A 2014

Notes:

Other base needs: 4,000 gal off-load tank and manifold pipes from mixing area to loading pits required.

Contractors’ personnel required to obtain ID’s and flightline driver’s licenses.

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Hill Gorman Rupp 54A2-VG4D Wisconsin VH4D Load Pump 1 000403 Hill Paco 310581 BALDOR ELEC. JMM4108T Load Pump 2 002020 Hill Paco 310581 Baldor Elec. JMM4108T Recirc Pump 002003 Hill Monarch 5BSGF-* Briggs & Stratton 133233 Off-Load Pump 002004 Hill Gorman Rupp T4A60-B Baldor M4115T Backup na

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 15

A-R04-05 FS McCall, ID Required Delivery Period 28 June - 30 September VLATs No Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 70,000 gal SEATs Yes Pits 2 MAFFS No Simultaneous Pits 2 Offload Capacity 6,000 gal Water Supply 1 – 13,000 gal. Water Tank, Supplied by municipal water.

Electrical Supply 3 - electric panels Storage 2- Garage Bays; 6-spaces Covered Parking as open air storage.

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 Forklift N/A N/A N/A N/A N/A 4 10,000 gal retardant tank N/A N/A N/A N/A N/A 1 13,000 gal water tank N/A N/A N/A N/A N/A 1 5,000 gal off-load tank N/A N/A N/A N/A N/A 1 10,000 gal waste water containment tank N/A N/A N/A N/A N/A 1 15,000 gal storm water run-off tank N/A N/A N/A N/A N/A 1 Manifold to 2 pits N/A N/A N/A N/A N/A 1 Lot, loading hoses N/A N/A N/A N/A N/A 2 Loading gas pumps Gorman Rupp 84A3B/Wisconsin W4-1770 N/A N/A 2 Electric loading pumps Gorman Rupp TF4676 / Lincoln U4B60B N/A N/A 1 Re-circ pump #1 MCM C286T17FB5C/Leeso N/A N/A N/A 1 Re-circ pump #2 Gorman Rupp 84A3B/Wisconsin W4-1770 N/A N/A 2 Back-up gas pumps N/A N/A N/A N/A N/A 1 Mass Flow System MicroMotion N/A N/A N/A N/A 1 Mass Flow System MicroMotion N/A N/A N/A N/A 1 Lot hardware and banding supplies N/A N/A N/A N/A N/A 1 Lot - 600' washdown hose and reel line N/A N/A N/A N/A N/A 1 Lot - storage and office space N/A N/A N/A N/A N/A

Notes:

Other base needs: 2 – LC Blenders, 4 – back flow valves, 1 – Back-up pump, 1 – Loading Hose.

Electric system is in good condition, but is undersized at capacity. All loading hose end electrical pump switching conduit and load display cables are Agency supplied.

Electrical system wont run all pumps when batch mixing.

Agency does not provide Phone, Computer, Internet Access

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

McCall Blender Canadian 001275 McCall Blender Canadian 001274 McCall Back Check Valve Stainless 001912 McCall Back Check Valve Stainless 001913 McCall Back Check Valve Stainless 002087 McCall Back Check Valve Stainless 002088 McCall Wacker PTS4 Briggs & Stratton Vanguard Off-Load Pump 001964 McCall Tank 20k steel water Water tank McCall Air Compressor Speedaire Briggs & Stratton 3Z430C

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 16

A-R04-06 BLM Pocatello, ID Required Delivery Period 23 June - 7 October VLATs *Yes Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 62,100 gal SEATs Yes Pits 2 MAFFS No Simultaneous Pits 1 Offload Capacity 5,000 gal Water Supply Municipal water supply - 12" service at 500 gpm Electrical Supply Agency supplied 3 phase, 225 amp 120/240 volt at mixing pad.

Storage Some on-site storage during operating season. No winter storage.

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

2 10,000 gal retardant tanks N/A N/A N/A N/A N/A 1 10,000 gal water tank N/A N/A N/A N/A N/A 1 Load pump 1 - 20HP Monarch EP 5KE254AC105B/GE N/A N/A N/A 1 Load pump 2 - 20HP Aurora 411 R8761/US Motor N/A N/A N/A 1 Backup pump - 15HP Crane Deming 3M 4021 N/A N/A N/A 1 Forklift N/A N/A N/A N/A N/A 2 Mass Flow System MicroMotion N/A N/A N/A N/A 1 Lot, hoses and manifold system N/A N/A N/A N/A N/A 1 Storage for operating season N/A N/A N/A N/A N/A

Notes:

* VLAT - DC10 only 5,000 gal offload tank required. Recirc system required.

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Pocatello Wacker PTSV4 Vanguard 303447 Seat/offload 001413 Pocatello Gorman Rupp 14A2B Marathon Electric Recirc Pump 001004/ 2616 (2015) Pocatello Off Load Tank 5k Steel

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 17

A-R04-07 BLM Stead, NV

Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 150,000 gal SEATs Yes Pits 2 MAFFS Yes Simultaneous Pits 2 Offload Capacity 5,000 gal Water Supply Municipal - 3" supply at 200 gpm.

Electrical Supply 400 amp, 3-phase, 220V Storage Limited space for storage

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

2 Mass Flow System MicroMotion N/A N/A N/A N/A 1 sand/oil spearator available for use N/A N/A N/A N/A N/A 1 Lot, storage N/A N/A N/A N/A N/A

Notes:

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Stead Deming Toshiba 80254FFF1A3 Load Pump 1 001646 Stead Deming 40710400 Marathon X3284TT Load Pump 2 001647 Stead Gorman Rupp 14A2 Marathon UE256TTFS Recirc. Pump 1 001669 Stead Gorman Rupp 13D-1 Briggs & Stratton Off-Load Pump 001649 Stead Tank Off-load 6K steel 001655 Stead Blender Valve

Stead Cutler Hammer Control Pannel Stead Wacker PTS4V Vanguard 5918470 2716 Stead Tank Water 10K steel 001654 Stead Reclaim Tank 10K steel 001679 Stead Tank Retardant #1 10K steel 001680 Stead Tank Retardant #2 10K steel 001671 Stead Tank Retardant #3 10K steel 001672 Stead Tank Retardant #4 10K steel 001673 Stead Conex Co 9610560 CAXU-247754 7 Stead Offload Tank 001650 Stead Shed Tuff-Shed

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 18

A-R04-08 BLM Twin Falls, ID Required Delivery Period 15 June - 30 September VLATs No Product LC95A-R (Lot #: 1051695-C) LATs Yes Daily Peak Req 60,000 gal / 10,000 gal concentrate SEATs Yes Pits 2 MAFFS Yes Simultaneous Pits 1 Offload Capacity 10,000 gal Water Supply Municipal supply through six inch service, flowing at 500 gpm Electrical Supply Multiple 3 phase, 480 volt, 4 wire, 600 amp power panels located in the plant area Storage 2 - 5,000 gal, no indoor over-winter storage available. Office area available storage for contractor use

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

2 5,000 gal off-load/storage tank (steel) N/A N/A N/A N/A N/A 1 180,000 gal storage pond N/A N/A N/A N/A N/A 1 Electric off-load/recirc pump w/ motor, 430 gpm Gorman Rupp N/A N/A N/A N/A 1 Diesel pump w/ motor for water load, 350 gpm N/A N/A N/A #RZ00246 N/A 1992 1 Water pump Deutz F31912 Libby Corp N/A N/A N/A 1 Mass Flow System MicroMotion N/A N/A N/A N/A 1 FEMA office trailer N/A N/A N/A #5CH200R34911558 N/A 1 Lot, loading hoses and fittings N/A N/A N/A N/A N/A 6 Mobile Aerial Retardant Operation Trailer Systems MAROTS N/A N/A N/A N/A

Notes:

Require 4 - 10,000 gal tanks, blender system and associate lines Require 1 - 450 GPM electric pump/motor, 1 - 250 GPM gasoline pump/engine, 1 - 300 GPM gasoline reload pump

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Twin Falls Deming 3M Baldor FT EM0006 Load Pump 1 001858 Twin Falls Deming 3M Wisconsin V465D1 FTGE0007 Load Pump 2 001856 Twin Falls Gorman Rupp 14A2 Toshiba b0204flf2uk Backup Recirc 001895 Twin Falls Wacker PTS4V Vanguard 305447 Off-Load Pump 001903 Twin Falls Blender Valve Twin Falls Blender Valve

Twin Falls Check Valve Twin Falls Check Valve Twin Falls Compressor Craftsman 919 2 HP, 33 Gal Twin Falls Tank Retardant 10K steel LC Tank Twin Falls Disconnect Pannel Cutler Hammer Twin Falls Tank Retardant 10K steel LC Tank Twin Falls Tank Retardant 10K steel LC Tank Twin Falls Pump Gorman Rupp 14A2- Landmark 4020TX Recirc. Pump 1 Twin Falls Trash Pump Multi Quip QP3TH Honda gx 240 Water Pump none Twin Falls Water Tank 10k steel water tank Twin Falls Tank Off load 4k steel

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 19

A-R04-09 BLM Winnemucca, NV

Product LC95A-R (Lot #: 1051695-C) LATs No Daily Peak Req 30,000 gal SEATs Yes Pits 1 MAFFS No Simultaneous Pits 1 Offload Capacity 3,000 gal Water Supply Agency provided, 200 GPM Electrical Supply 220V Storage Limited storage

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

2 5,000 gal poly water tanks N/A N/A N/A N/A N/A 1 Mass Flow System MicroMotion N/A N/A N/A N/A 1 Lot, office, workshop and WiFi available N/A N/A N/A N/A N/A

Notes:

Office, workshop and WiFi available for contractor Contractor provides pumps, hoses, valves, recirc system, off load system, plumbing for water system

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Winnemuc * HONDA 4F0YV1 HONDA GX340 Load Pump 1 002170 Winnemuc * Gorman Rupp 14A2 Wisconsin VH4D Recirc. Pump 1 001493 Winnemuc * HONDA QP-3TH HONDA GX242 Backup 002169 Winnemuc HONDA 4f0yv1 Honda GX340MAX-337 Off Load / Back Up P 2606 * Winnemuc * Tank Retardant 8k steel 001644 Winnemuc 12k LC Tank LC Tank Winnemuc Wacker PTS4V Vanguard Briggs Stratton 16HPLoad Pump 1 2163 Winnemuc Blender Similar to Canadian Blender 2599 Winnemuc Recirc Pump Riverside TP4V Vanguard Briggs Stratton 16HPRecirc Pump Winnemuc Offload Tank 2600 Gallon Poly Winnemuc Air Compressor Campbell Hausfeld 200 PSI none Winnemuc Water Tank 4500 Gallon Poly

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 20

A-R05-01 FS Castle AFB, CA Required Delivery Period 1 June - 30 September VLATs *Yes Product MVP-Fx (Lot #: 0403014-A/B) LATs Yes Daily Peak Req 130,000 + gal SEATs Yes Pits 2 MAFFS Yes Simultaneous Pits 2 Offload Capacity 12,000 gal Water Supply Municipal water supply (Min 350 GPM) Electrical Supply 400 amp; 220 volt Storage No indoor over-winter retardant storage avail. Office area and Tough storage shed avail.

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 Mass Flow Meter System MicroMotion N/A N/A N/A N/A 1 Mass Flow Meter System MicroMotion N/A N/A N/A N/A 2 Mass Flow Water Meter N/A N/A N/A N/A N/A 1 Lot storage N/A N/A N/A N/A N/A

Notes:

* VLAT - DC10 and 747 Castle has been operated with a reduced price Portable VLAT system for several years on the Full Service contract.

Other needs: 2-25K Gallon Steel Tanks w/recirc sys; 350 GPM Eductor Mix System; Containment berm; 2-mechanical pumps (500GPM to 2 pits simult.); forklift

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Castle Poly Tank 3500 Castle Storage Tanks 10k Castle Storage Tanks 10k Castle Air Blowers Honda GX160-5.5HP SPARE 002216 Castle Gorman Rupp 04A13-F3L Deutz Diesel F3912 002668 Castle Gorman Rupp 04A13-F3L Deutz Diesel F3912 002669 Castle Forklift Catipiller

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 21

A-R05-02 FS Chester, CA Required Delivery Period 15 June - 15 October VLATs No Product MVP-Fx (Lot #: 0403014-A/B) LATs Yes Daily Peak Req 30,000 gal SEATs Yes Pits 3 MAFFS No Simultaneous Pits 3 Offload Capacity 6,500 gal Water Supply Utility District owned from 8” metered main on containment area. Water by contractor Electrical Supply 3 phase, 400 amps, 480 volts Storage Some covered storage available for winter and 40’ X 100’ uncovered area at mix plant

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 Forklift N/A N/A N/A N/A N/A 1 5,000 gal off-load tank N/A N/A N/A N/A N/A 1 Mass Flow System MicroMotion N/A N/A #14254932 N/A 2011 1 Mass Flow System MicroMotion N/A N/A #14255681 N/A 2011 1 Mass Flow System MicroMotion N/A N/A #14254934 N/A 2011 1 sand/oil separator available N/A N/A N/A N/A N/A 1 Lot storage N/A N/A N/A N/A N/A

Notes:

Contractor to provide 2 - 25,000 gal storage tanks, educator & transfer pumps w/1 gas powered back up pump and off-load pump Agency owned 3 Model 8000 Westrex Printers, S/N’s 8515A00238, 8515A00240, 8515A00237

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Chester Deming 4021 US Electric a4898-00171 Load Pump * /Recirc 002246 Chester Deming 4021 US Electric a4898-00171 Load Pump 3 001130 Chester Deming 4021 Wisconsin V465D1 Load Pump 4 # Backu002151 Chester Gorman Rupp 53H2 Wisconsin VF4D Water 000483 Chester Eductor 001674 Chester Water Meter Micrometer 001675 Chester Tank Retardant 25K Steel 001126 Chester Tank Retardant 25K Steel 001127 Chester Control Panel Chester Cutler Hammer Control Pannel Chester Forklift Clark CGP25 Chester Wacker PG3 Honda GX160 001416 Chester Air Blowers Honda GX160 001009 Chester Forklift CATVC600 No Number Chester Deming 4021 2247 Chester McCrometer 000624 Chester Air Blowers Baldor 001010 Chester Hopper Mixer #1 002527 Chester Hopper Mixer #2 002528 Chester Super-Sac Horse? 002518 Chester Steps to Hopper 002524 Chester Wilkins 375A Backflow preventer On Water Main X26775 Chester Dust collector? 002518 Chester Deming 4021 Wisconsin VG4D Mix Pump (New 2015000524 Chester

Solicitation No. 12024B18R9006 National Long-Term Fire Retardant Attachment 3 - Section J-1

US Forest Service

J-1 - 22

A-R05-03 FS Fox Field (Lancaster), CA Required Delivery Period 1 June - 30 November VLATs No Product MVP-Fx (Lot #: 0403014-A/B) LATs Yes Daily Peak Req 120,000 gal SEATs Yes Pits 5 MAFFS Yes Simultaneous Pits 5 Offload Capacity 2,000 gal Water Supply Agency provided. 6” main, 4” supply to mix area Electrical Supply Agency provided 3 phase, 184/92 amp, 230/460 volt, 60hp 3 phase 100/50 amps Storage Limited covered storage area available. Unlimited open area storage

Government Furnished Equipment Qty Description Manufacturer Part Number Model Number Serial Number Condition

1 Forklift N/A N/A N/A N/A N/A 1 3,000 gal off-load tank N/A N/A N/A N/A N/A 2 40,000 gal retardant storage tank N/A N/A N/A N/A N/A 1 10,000 gal water storage tank N/A N/A N/A N/A N/A 1 2,000 gal offload tank N/A N/A N/A N/A N/A 1 75 hp Electric loading pump N/A N/A N/A N/A N/A 1 Mass Flow Meter System MicroMotion N/A N/A N/A N/A 1 Mass Flow Meter System MicroMotion N/A N/A N/A N/A 1 Mass Flow Meter System MicroMotion N/A N/A N/A N/A 1 Mass Flow Meter System MicroMotion N/A N/A N/A N/A 1 Mass Flow Meter System MicroMotion N/A N/A N/A N/A 1 Lot, water supply plumbing N/A N/A N/A N/A N/A 1 Lot, plumbing from storage tanks to off-load tanks N/A N/A N/A N/A N/A 1 lot, underground plumbing N/A N/A N/A N/A N/A 1 lot, storage N/A N/A N/A N/A N/A

Notes:

Contractor to provide 3 - electric loading pumps (60 hp), 1 - Gas loading pump for emergency back-up and hoses, skates, fittings, valves Contractor provides all connections from power supply to pumps.

ICL Owned Equipment:

location Pump Make Pump Model Motor Brand Motor Model category serial num pc

Fox Paco 310581 Baldor JMM4108T Load Pump Fox Deming 4021 US Electric a4898-00171 Load Pump 1 001128 Fox Gorman Rupp 66B2B Leeson C364T17DB7E Load Pump 1 002160 Fox Paco 11-50757-045205 Marathon xd326ttff8026a Load Pump 2 002123 Fox Gorman Rupp 55A2-B Reliance A205476 Load Pump 4 002158 Fox Gorman Rupp 54J20 Reliance 34284BB Load Pump 5 002157 Fox Gorman Rupp 13D-19 Briggs & Stratton 190432 Off-Load Pump 002156 Fox…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.