10GB ADDITIONAL TECH SG25OCT227873.pdf
PDF 37 KB Posted
- Solicitation number
- HC101323QA113
- Issued by
-
Defense Information Systems Agency
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Vendor Block Diagram Sample and Maps.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDITIONAL TECHNICAL SPECIFICATIONS
1. VENDOR MUST MEET SVC DATE.
2. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS: (A) FIBER TERMINATION: SINGLE-
MODE INTERFACE REQUIREMENT/INTERFACE DATA RATE: LINE CODING, FRAME FORMAT,
PHYSICAL CONNECTOR, 10 GBPS, NRZ, SCRAMBLED PER ANSI T1.104-1991 (R2003). ALL
OPTIONS DEFINED SC CONNECTOR, SINGLE-MODE FIBER PER ANSI T1.105.06-2002 (SR-0,
SR-1, IR-1, IR-2, LR-1, LR-2, LR-3). (B) LINE MUST REMAIN FULLY OPERATIONAL AND
AVAILABLE TO USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, AT LEAST 99.5% OR
BETTER. (C) ONE-HOUR RESPONSE TIME TURN-AROUND MUST OCCUR TO REPAIR ONCE
TROUBLE-CALL HAS BEEN REPORTED. (D) GFE CLOCKING: VENDOR ESFU (OR
EQUIVALENT) NOT TO BE ENGINEERED INTO CIRCUIT. (E) SINGLE MODE FIBER
TERMINATIONS "SC" CONNECTORS. (F) NO NETWORK INTERFACE UNIT. (G) DEDICATED
PATH. (H) CARRIER REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT
OUTAGES. (I) THE VENDOR MUST CONDUCT A 72 HOUR SATISFACTORY END TO END TEST
ON THE 10GB WAVE SERVICE IAW ITU STANDARD M.2101. ADDITIONALLY, THE VENDOR
TEST SET/SETS MUST HAVE THE ABILITY TO PRINT THE TEST RESULTS AND THOSE
RESULTS MUST BE EMAILED TO THE ACCEPTING AUTHORITY FOR REVIEW. (J) VENDOR
MUST HAVE A 24X7 NETWORK OPERATIONAL CENTER. (K) THE COMMERCIAL CIRCUIT
WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT BY THE DGOC: PRI POC: DISA
GLOBAL CASA INFRASTRUCTURE INTEGRATION LEASE BB TEAM PHONE: (C) 618-418-9813,
(D) 418-9813 EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-INTEGRATION-
LEAS E-BB-T@MAIL.MIL ALT POC: ORGANIZATIONAL NUMBER (CASA RF CIRCUIT
ACTIVATIONS) PHONE: (C) 618-418-8691, (D) 418-8691 EMAIL: DISA.SCOTT.GLOBAL.MBX.RF-
CIRCUIT-ACTIVATIONS@MAIL.MIL (L) THE VENDOR MUST PROVIDE THE LONG HAUL
CIRCUIT NUMBER AND THE 1-800 TROUBLE REPORT NUMBER TO THE ACCEPTING
AUTHORITY PRIOR TO THE GOVERNMENT ACCEPTING SERVICE. INSIDE WIRING MUST BE
COMPLETED AND TESTED PROPERLY IAW THE ORDER PRIOR TO TURN-UP TO THE
GOVERNMENT.
3. VENDOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE
FIBER IAW UNIQUE INSTALLATION FACTORS.
4. INSIDE WIRING IS AUTHORIZED IAW WITH THE UNIQUE INSTALLATION FACTORS.
5. VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO
REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS.
6. FOR UNSATISFACTORY SERVICE OR TO REPORT EQUIPMENT AND/OR CIRCUIT
PROBLEMS INVOLVING DISA PROVIDED TRANSPORT AND/OR P. REMARKS CONTINUED:
EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT CENTER (DCCC) SCOTT
AFB, IL. TOLL FREE: 1-855-868-9500, COML: 618-418-9500, DSN: 312-418-9500.
File details come from the government source that posted it. Updated .