100 percent Drawings Compiled 2023 03 24.pdf

PDF 17 MB Posted

Attached to
Bathroom Deficiency Remediation Project No. 539-22-207
Solicitation number
36C25023B0054
Issued by

About this file

This document provides details on a federal contract opportunity from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 for bathroom deficiency remediation project number 539-22-207. The solicitation number is 36C25023B0054 and seeks bids to complete bathroom repairs and upgrades at a VA facility. Key requirements include addressing deficiencies in bathrooms through activities such as plumbing repairs and replacements, fixture replacements, and accessibility upgrades. The project scope and related 100 percent drawings are available for review in the attached 17MB PDF file. The response due date and anticipated award date are not specified.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

DN

UP

UP

UP UP

UP

UP

DN

UP

UP

DN

UP

UP

UP

DN

UP

UP

UP

DN

UP

DN

UPDN

UP

DN

UP

UP

UP

UP

EXTERIOR ELEVATION

INTERIOR ELEVATION

SECTION/DETAIL NUMBER

DRAWING NUMBER

EQUIPMENT TAG

COLUMN GRID

NOTE

WINDOW OPENING

DOOR OPENING

ROOM NAME

ROOM NUMBER

WALL TYPE

CEILING HEIGHT

FINISH DESIGNATION

X

10'-8"

X

X

XX.X-X

XX

X

1/A101

X

A101

XX

TOILET ACCESSORY TAGX SIGNAGE TAG

A101

SIM

X

Ludlow Ave.

C lif to n A v e

CINCINNATI

STATE

TECH.

Hopple St.

M.L.K. Dr.

McMillan St.

UNIV. OF

CINCINNATI

W.H.T Rd.

VAMC

3200 VINE ST.

M.L.K. Dr.

V in e

S t.

ZOO

Jefferson A ve.

UNIV.

HOSPITAL

Mitchell Ave.

R ea di ng

R d.

V ic to ry

P kw

y. XAVIER

UNIV.

PHASE 2

AREA OF WORK

(Bid Item #4- Delete Phase 2 Work) A004C - Men Toilet A004D - H.A.C.

A004E - Women Toilet

PHASE 3

AREA OF WORK

B010 - Men Toilet

B008 - Unisex Toilet

PHASE 1

AREA OF WORK

A025 - H.A.C.

A026 - Men Toilet A026A - Women Toilet A026B - Locker Room

(Bid Item #3- Delete Work in Room B008)

(Bid Item #2- Delete Lockers)

(Bid Item #2- Delete Lockers)

(Bid Item #2- Delete Lockers)

JASON

H.

ROSS

2118221

IO

HO

FOET

A T

S

R E G I S

E T

R

ED RA

C H

TI

E C T

VA Project No.

RDC/JPA Project No.

Department of Veterans Affairs Medical Center

HEAPY ENGINEERING

MECHANICAL ELECTRICAL COMMISSIONING TECHNOLOGY

1400 WEST DOROTHY LANE

DAYTON, OH 45409

937.224.0861 P

ARCHITECTURE PLANNING INTERIOR DESIGN

524 FERNWOOD AVENUE

ALTAMONTE SPRINGS, FLORIDA 32701

407.830.6522 P

RDC / JOHN POE ARCHITECTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

TERRACON CONSULTING, INC.

ENVIRONMENTAL

611 LUNKEN PARK DRIVE

CINCINNATI, OH 45226

513.321.5816 P

/2

/2

:0

:4

P

M

VA Cincinnati Bathroom Deficiency Remediation

03/24/2023

COVER SHEET

G001

JWKR

539-22-207

Cincinnati, OH

VA Cincinnati Bathroom Deficiency Remediation

3200 Vine Street Cincinnati, OH 45220 PROJECT #: 539-22-207

Kristina Amin

100% Bid Documents 22034.00

G001 COVER SHEET

G100 CODE DATA - BASEMENT

A101 NEW WORK PLAN - PHASE 1

A102 NEW WORK PLAN - PHASE 2

A103 NEW WORK PLAN - PHASE 3

A311 WALL SECTIONS

A401 INTERIOR ELEVATIONS

A402 INTERIOR ELEVATIONS

A601 SCHEDULES, SECTIONS & DETAILS

F001 ABBREVIATIONS, LEGEND & DRAWING INDEX

P001 ABBREVIATIONS, LEGEND & DRAWING INDEX

FX100 PARTIAL FLOOR PLANS - FIRE SUPPRESSION

PP101 NEW WORK PLANS - PHASE 1

PP102 NEW WORK PLANS - PHASE 2

PP103 NEW WORK PLANS - PHASE 3

P601 SCHEDULES, DETAILS & SWV DIAGRAMS

P602 DOMESTIC WATER DIAGRAMS

M001 ABBREVIATIONS, LEGEND & DRAWING INDEX

MD100 PARTIAL BASEMENT PLANS - REMOVALS

MH100 PARTIAL BASEMENT PLANS - NEW WORK

M501 SCHEDULES & DETAILS

E001 ABBREVIATIONS, LEGEND & DRAWING INDEX

ED100 PARTIAL BASEMENT PLANS - REMOVALS

EE100 PARTIAL BASEMENT PLANS - NEW WORK

E601 SCHEDULES & DIAGRAMS

E602 PANEL SCHEDULES

GENERAL CONSTRUCTION NOTES

7. CONTRACTOR IS RESPONSIBLE TO VERIFY SIZES OF ALL EQUIPMENT, ETC. TO

BE INSTALLED AS PART OF THIS PROJECT, AND WHERE NECESSARY, MAKE

SPECIAL PROVISIONS TO INSTALL EQUIPMENT THAT IS TOO LARGE TO FIT

THROUGH FINISHED OPENINGS.

8. CONTRACTOR SHALL PROVIDE WOOD BLOCKING AT TOILET ACCESSORIES,

HAND RAILS, BUMPER RAILS, SHELVING, CASEWORK, MOUNTING BRACKETS

AND OTHER WALL MOUNTED ITEMS, AS INDICATED IN THE CONTRACT

DOCUMENTS AND AS RECOMMENDED BY PRODUCT MANUFACTURERS. ALL

WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED.

9. ALL EXPOSED NEW WORK IS TO RECEIVE NEW FINISHES UNLESS

SPECIFICALLY NOTED OTHERWISE. iF NO FINISH IS INDICATED AT A

PARTICULAR SURFACE, CONTRACTOR SHALL PROVIDE FINISH(S) AS

INDICATED AT SIMILAR CONDITIONS.

10. CONTRACTOR SHALL PROVIDE COMPLETE AND FULLY OPERATIONAL

SYSTEMS WHICH COMPLY WITH STATED CODES AND REGULATIONS. WHERE

THE OMISSION OF A PART OR ELEMENT OF A SYSTEM WOULD RESULT IN THE

NON-OPERATION, OR INCORRECT OPERATION OF A SYSTEM, CONTRACTOR

SHALL INCLUDE SAID PART OR ELEMENT AS PART OF THE WORK.

11. ALL PENETRATIONS THROUGH NEW AND/OR EXISTING SMOKE OR FIRE RATED

WALLS SHALL BE SMOKE/FIRE STOPPED AS REQUIRED BY THE RATING OF

THE WALL.

12. FIRE PROTECTION CONTRACTOR'S SPRINKLER DESIGN WILL BE SUBJECT TO

AN INDEPENDENT REVIEW BY A CERTIFIED FIRE PROTECTION ENGINEER

RETAINED BY THE OWNER. THE FIRE PROTECTION CONTRACTOR IS

RESPONSIBLE FOR MAKING ANY REQUIRED CHANGES TO THE DESIGN AS

IDENTIFIED BY THE OWNER'S FIRE PROTECTION ENGINEER AS NECESSARY

FOR COMPLIANCE WITH SPECIFIED NFPA REQUIREMENTS.

* PLEASE NOTE THAT THE TERM PROJECT ENGINEER REFERS TO THE

CONTRACTING OFFICER'S REPRESENTATIVE (C.O.R.).

1. ALL WORK SHALL COMPLY WITH THE LATEST NFPA 101 LIFE SAFETY CODE,

INTERNATIONAL BUILDING CODE, AND OTHER COES AS IDENTIFIED IN VHA

PROGRAM GUIDE PG-18-3, TOPIC 01, CODES, STANDARDS AND EXECUTIVE

ORDERS WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERAN AFFAIRS,

TECHNICAL INFORMATION LIBRRARY WEBSITE.

2. ALL WORK SHALL COMPLY WITH REQUIREMENTS OF THE LATEST

ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS) AND

DEPARTMENT OF VETERANS AFFAIRS BARRIER FREE DESIGN GUIDE PG-18-13

WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERANS AFFAIRS

TECHNICAL INFORMATION LIBRARY WEBSITE.

3. CONTRACTOR IS RESPONSIBLE TO VISIT THE SITE, EXAMINE AND ACCEPT

EXISTING CONDITIONS PRIOR TO BIDDING. SITE VISITS TO BE COORDINATED

WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.

4. CONTRACTOR IS RESPONSIBLE TO REPAIR AND/OR REFINISH, TO MATCH

ADJACENT EXISTING SURFACES, ANY EXISTING MATERIALS TO REMAIN THAT

ARE DAMAGED DURING THE COURSE OF DEMOLITION OR NEW WORK.

5. WHERE REMOVAL OF EXISTING WORK IS REQUIRED FOR INSTALLATION OF

NEW WORK, CONTRACTOR SHALL REPAIR EXISTING CONSTRUCTION TO

REMAIN OR PROVIDE NEW CONSTRUCTION TO MATCH EXISTING ADJACENT

SURFACES TO REMAIN.

6. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL CONDITIONS AND

DIMENSIONS PRIOR TO ORDERING, FABRICATING OR INSTALLING NEW

MATERIALS.

DRAWING INDEX

GRAPHIC SYMBOLS

N.T.S.Scale:

VICINITY MAP

KEYPLAN - Basement

Revisions Date

1 95% Resubmittal 03/09/2023

0-HR Smoke Partition - [OBC 710] / NFPA 101-8.4

1/2-HR Smoke Barrier - [OBC 710] / NFPA 101-8.4

1-HR Smoke Barrier - [OBC 709] / NFPA 101-8.5

2-HR Smoke Barrier - [OBC 709] / NFPA 101-8.5

1-HR Fire Barrier - [OBC 706] / NFPA 101-8.3

2-HR Fire Barrier - [OBC 706] / NFPA 101-8.3

Hazardous Area

Means of Egress

Existing Wall to Remain

New Wall

Emergency Lighting

Fire Extinguisher

Exit Sign

Exit

Suite Designation

CODE LEGEND

EX

PHASE 3:

B008 -Unisex Toilet B010 - Men Toilet/Shower

PHASE 1:

A025 - H.A.C.

A026 - Men Toilet A026A - Women Toilet/Shower A026B - Locker Room

PHASE 2:

A004C - Men Toilet/Shower A004D - H.A.C.

A004E - Women Toilet/Shower

JASON

H.

ROSS

2118221

IO

HO

FOET

A T

S

R E G I S

E T

R

ED RA

C H

TI

E C T

VA Project No.

RDC/JPA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

/2

/2

:0

:5

P

M

VA Cincinnati Bathroom Deficiency Remediation

03/24/2023

CODE DATA - BASEMENT

G100

JWKR

539-22-207

Cincinnati, OH

Kristina Amin

100% Bid Documents 22034.00

N Scale: 1/16" = 1'-0"

B01 - BASEMENT - Life Safety Plan

Code: NFPA 101 Life Safety Code (2021 Edition)

Construction Type: Type II (222)

Occupancy: Health Care Occupancy

Area of Work: 1,409 SF - VA Cincinnati Bathroom Deficiency Remediation

Protection: Fully Suppressed

Chapter 4 - General

• 4.4.2.2 -Prescriptive-based life safety design meeting the requirements of Chapters 1 thru 3, Sections 4.5 thru 4.8, and

Chapters 6 thru 43 of this Code shall be deemed to satisfy the provisions of Sections 4.1 and 4.2.

• 4.4.2.3 -Where req’ts in Chapters 11 thru 43 differ from req’ts in Chapters 1 thru 4 and 6 thru 10, the req’ts of Chapters 11 thru 43 shall govern.

• 4.6.1.1 -The authority having jurisdiction (AHJ) shall determine whether the provisions of this Code are met.

• 4.6.7.1 -Rehabilitation category per 43.2.2.1.2 Renovation.

Chapter - 6 Classification of Occupancy and Hazard of Content

• 6.1.5 - Health Care Occupancy - (No Change)

• 6.2.2.1 -Hazard classification = Ordinary - (No Change)

Chapter 7 - Means of Egress

• 7.1.3.1 - Exit Access Corridors: 1/2 hr. fire rating is required for corridor walls per 19.3.6.2.2

• 7.3.1.2 – Occupant Load:

Basement Floor (Renovation):

HC - Inpatient treatment Dept: 994 sf @ 240 sf/occ = 5 occup (NO CHANGE in area or occupant load) Storage: 145 sf @ 300 sf/occ = 1 occup (NO CHANGE in area or occupant load) Total: 1,139 sf

Chapter 8 - Features of Fire Protection:

• Table 8.3.3.2.2 – Min Fire Protection for Openings in Fire-rated Assemblies:

Component Walls Fire Drs Vision Panel (size) FR Vision Panel FR Window Vert. shafts 2 hr 1-1/2 hr Max tested D-H-90 NP (stairs, exits):

Fire Barriers: 2 hr 1-1/2 hr Max tested D-H-90 NP

1 hr 3/4 hr Max tested D-H-45 3/4 hr Smoke Barriers: 1 hr 1/3 hr Max tested D-20 3/4 hr

1/2 hr 1/3 hr Max tested D-20 1/3 hr Smoke Part'ns: 1 hr 1/3 hr Max tested D-20 3/4 hr

1/2 hr 1/3 hr Max tested D-20 1/3 hr

• 8.3.4.2.1 – Firestop Systems – Penetrations that pass thru a fire barrier shall be protected by a firestop system or device.

• 8.3.4.2.2 – The firestop system or device shall be tested in accordance with ASTM E814 or UL 1479.

• 8.3.4.8 – Openings thru fire barriers for air-handling ductwork or air movement shall be protected per 9.2.1.

• 8.4.1 - Smoke Partitions shall limit the transfer of smoke.

• 8.5.1 - Smoke Barriers shall restrict the transfer of smoke and have 1/2 hour fire resistance rating per 19.3.7.3 (1 hour provided).

• 8.5.3 - Fire Barriers that meet requirements of Section 8.5 shall be permitted to be used as a smoke barrier.

Chapter 9 - Building Service and Fire Protection Equipment

• 9.6.1.3 – Fire Alarm System req’d for life safety shall be per NFPA 70 (2020) and 72 (2019).

• 9.7.1.1 – Supervised automatic sprinkler system as req’d by 9.7.1 and 19.3.5.3 and shall comply with NFPA 13 (2019).

Chapter 10 – Interior Finish, Contents, and Furnishings

• 10.2.2- Interior Finish Classification Limitations

Table A.10.2.2 - Interior Finish Classification Limitations: Health Care (Existing) Exit Access Corridors: Class A or B.

Other Spaces: Class A or B.

• 10.2.3.1.1 - Interior wall and ceiling finish materials shall be classified in accordance with NFPA 286 and comply with 10.2.3.2.

• 10.2.3.1.2 - Materials tested in accordance with 10.2.3.1.1 and complying with 10.2.3.2 shall also be considered to comply with the requirements of Class A in accordance with 10.2.3.3.

• 10.2.3.3 – Wall and Ceiling – Classifications characteristics:

(1) Class A: Flame spread: 0-25; Smoke dev.: 0-450.

(2) Class B: Flame spread: 26-75; Smoke dev.: 0-450.

(3) Class C: Flame spread: 76-200; Smoke dev.: 0-450.

• 10.2.3.3.1 – Existing interior finish exempt from smoke dev. criteria.

• 10.2.7.2 – Floor finish other than carpet: Min. Rad flux: .1 W/ cm².

• 10.2.8.1 – Wall and Ceiling finishes, where sprinkled:

Class C permitted in any location where Class B is req’d.

Class B permitted in any location where Class A is req’d.

• 10.2.8.2 – Floor finishes, where sprinkled:

Class II permitted in any location where Class I is req’d.

Provisions of 10.2.7.2 shall apply where Class II is req’d.

Chapter 19 - Existing Health Care Occupancies

• 19.1.1.1.4 - The area of work is an existing hospital and therefore falls under Chapter 19.

• 19.1.1.4.3.1 - For the purpose of the provisions of this chapter the following shall apply:

1. A minor rehabilitation shall involve the modification of not more than 50%, and not more than 4,500 s.f. of the area of the smoke compartment.

• 19.1.6.1 - Construction Type Limitations (Table 19.1.6.1): Type II (222), sprinklered, no story limitations. (No Change)

• 19.1.7 - Occupant Load per Table 7.3.1.2. (NO CHANGE)

• 19.3.4.1 - Health care occupancies shall be provided with a fire alarm system per Section 9.6.

• 19.3.5.3 - Building containing hospitals shall be protected throughout by approved, supervised automatic sprinkler systems per Section 9.7.

• 19.3.6.2.2 - Corridor walls shall have min. 1/2 hour fire resistance rating. (NO CHANGE)

• 19.3.6.2.3 - Corridor walls shall form a barrier to limit the transfer of smoke but are not required to be smoke barriers or smoke partitions.

• 19.3.6.3.1 - Corridor doors shall be doors constructed to resist the passage of smoke.

OCCUPANCY COUNT:

533 - TOTAL OCCUPANTS

267/MALE

267/FEMALE

FIXTURES NEEDED:

14 - TOTAL FIXTURES

7/MALE

7/FEMALE

EXISTING FIXTURE COUNT:

17 - TOTAL FIXTURES

8/MALE (6 STAFF / 2 PUBLIC)

6/FEMALE (4 STAFF / 2 PUBLIC)

3/UNISEX (1 STAFF / 2 PUBLIC)

PROPOSED FIXTURE COUNT:

18 - TOTAL FIXTURES

7/MALE (5 STAFF / 2 PUBLIC)

8/FEMALE (6 STAFF / 2 PUBLIC)

3/UNISEX (1 STAFF / 2 PUBLIC)

UP

UP

UP UP

UP

UP

DN

UP

UP

DN

UP

UP

UP

DN

UP

UP

UP

DN

UP

DN

UPDN

UP

DN

UP

UP

UP

UP

Toilet-Male

A026

H.A.C.

A025

Locker Room

A026B

Toilet-Female

A026A

A401

B13

A401

A

A401

A

A

A

A401

A401

A

A401

A

A401

A

A401

A401

A401

C

S1.0

S2.0

S2.0 S2.0S2.0

S2.0

S1.0S1.1

S1.0S2.0 S1.0

S2.0

S1.0

S2.0S2.0

S2.0

S2.0

S1.0

S2.0

S1.0

S1.0

3' - 8"

/8

1' - 4"5' - 8" 11' - 5 1/8"

5' - 9 7/8"

/4

6' - 0"

2' - 9 5/8" 2' - 9 5/8" 4' - 4" 3' - 0"

/8

4' - 7"3' - 11 1/4"

1' - 4"

5' - 0"

10' - 3 1/2"

/2

3' - 3 1/2"

1' - 9"

1' - 7 3/4"

/4

/4

/8

/8

/4

A026 A026A

A025

Existing Locker Count: 92 (Unisex) New Locker Count: 44 (Unisex) Half-height

2' - 6"

S2.0S1.0

4"

S2.0S1.0S1.0

9.35

S3.0S3.0

" 1

/4

S2.0

8'-0"

8'-0" 8'-3"

7'-6"

H.A.C.

A025

Toilet-Male

A026 Toilet-Female

A026A

Locker Room

A026B7'-6"

7'-5"

8'-0"

9.29

ACT-2

ACT-2

ACT-2

ACT

9.28

ACT-2

GYP

9.22

Locker Room

A026B

Toilet-Female

A026AToilet-Male

A026

H.A.C.

A025

PT-1

PT-1

PT-1PT-1

VCT-1VCT-1

VCT

H.A.C.

A025

Toilet-Male

A026 Toilet-Female

A026A

Locker Room

A026B

PT-2

PT-2

PTB-1

PTB-1

PTB-1

RB-1

P-1 P-1

PHASE 1

AREA OF WORK

A025 - H.A.C.

A026 - Men Toilet A026A - Women Toilet A026B - Locker Room

DEMOLITION LEGEND

Block wall to be demolished

Existing wall to remain

Door and frame to be demolished

2.55

2.59 2.60

2.60 2.61

2.57

2.57

2.572.57 2.572.57 2.572.57

2.572.57

2.58

2.592.59

2.55

2.55

2.61

2.60

A025 A026 A026B

A026A

2.54

2.72

2.54

2.72

2.53

2.72

2.542.54 2.53

2.10

2.10

2.58

1.038.05

1.03

8.05

2.07

2.07

2.53 2.72

2.07

2.07

2.07

2.72

2.07

2.04

2.16

9.31

2.63

2.07

2.52 2.52

9.31

REFLECTED CEILING PLAN LEGEND

Recessed downlight fixture

Supply Air Diffuser

Return Air Grille

2' x 4' light fixture

2' x 2' acoustical tile ceiling

Gypsum board / portland cement plaster ceiling / soffit - painted

Chain-hung light fixture

Exhaust Grille

2' x 2' light fixture

JASON

H.

ROSS

2118221

IO

HO

FOET

A T

S

R E G I S

E T

R

ED RA

C H

TI

E C T

VA Project No.

RDC/JPA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

/2

/2

:0

:5

P

M

VA Cincinnati Bathroom Deficiency Remediation

03/24/2023

NEW WORK PLAN - PHASE 1

A101

JWKR

539-22-207

Cincinnati, OH

Kristina Amin

100% Bid Documents 22034.00

N Scale: 1/4" = 1'-0"2

PHASE 1 NEW WORK PLAN - Basement A025, A026, A026A, A026B

N Scale: 1/4" = 1'-0"3

PHASE 1 NEW WORK RCP - Basement A025, A026, A026A, A026B

N Scale: 1/4" = 1'-0"5

PHASE 1 FLOOR FINISH PLAN - Basement A025, A026, A026A, A026B

N Scale: 1/4" = 1'-0"4

PHASE 1 WALL FINISH PLAN - Basement A025, A026, A026A, A026B

KEYPLAN - Basement

N Scale: 1/4" = 1'-0"1

PHASE 1 DEMOLITION PLAN - Basement A025, A026, A026A, A026B

1.03 Temporary Construction Barrier.

2.04 Existing floor finish to remain. Protect in place during construction.

2.07 Demolish existing block wall from floor to deck.

2.10 Remove existing toilet partitions.

2.16 Existing to remain.

2.52 Remove existing wall covering.

2.53 Remove existing ceramic tile flooring and coved base. Prep floor to receive new finishes.

2.54 Remove existing VCT floor finish and rubber base. Prep floor to receive new finishes.

2.55 Remove floor mounted plumbing fixture. Repair floor penetrations. Prep floor to receive new finishes.

2.57 Remove existing metal lockers.

2.58 Remove existing shower surround and shower base. Prepare subfloor for new schedule finish and base.

2.59 Remove wall-mounted plumbing fixture.

2.60 Remove and salvage all existing wall-mounted grab bars and toilet room accessories.

2.61 Remove existing mirror.

2.63 Remove existing door and door frame.

2.72 Remove existing ACT ceiling.

8.05 Temporary construction entrance door and frame with locking hardware.

9.22 Gypsum board header. See Detail.

9.28 Gypsum board bulkhead. See Detail.

9.29 Gypsum board ceiling.

9.31 Ceramic [porcelian] wall tile.

9.35 Solid Surface sill.

A. Remove all existing partitions shown with dashed line. Repair wall and floor finishes to match adjacent surfaces at areas of removal or scheduled new surfaces as required.

B. See Plumbing, HVAC and Electrical Drawings for removal work associated with those trades.

C. Computer and communication cables and/or other wiring, piping, tubing, etc.

serving other areas and functions located above ceiling or in walls of area to be remodeled shall be maintained during demolition/construction process.

D. Repair existing walls to match adjacent undisturbed wall where cabinets, countertops, etc. are shown to be removed.

E. Prepare walls and floor slabs as required to receive new fininsh materials where existing finish is indicated to be removed.

F. Prepare existing floor surface throughout the entire area of demolition and construction for new covering. Pour cementitious topping to fill voids, feather all edges to match adjacent floor elevations and correct low areas. Review and coordinate new floor drain locations and any floor slopes prior to slab prep.

G. Protect existing structure, adjacent windows, doors, and other building elements during demolition.

H. Provide tile substrate as follows: All shower stalls and tiled surfaces will receive Cementious backer units. All Bathrooms, Restrooms, HAC will receive Water-resistant gyp. board.

KEYNOTES

GENERAL DEMO NOTES

GENERAL NOTES

A. All dimensions are taken to face of gypsum wallboard or unit masonry.

B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.

C. All wood blocking to be fire retardent treated.

D. First floor level 100'-0" equals 728'-0".

E. All partitions shall be type 'S1.0' unless noted otherwise.

A. All wood blocking shall be fire retardant.

B. Light fixtures, sprinkler heads, speakers, and HVAC devices shall be located as close as possible to the center of acoustical ceiling panels.

Confirm any deviation from this with the Project Engineer.

C. See P, M, E and FP drawings for additional information regarding final information and quantites of fixtures/devices to be installed in ceiling.

D. All ACT ceilings in bathrooms to be Clean Room Type Washable ACT system.

D. See Electrical Drawings for lighting specifications.

E. All gypsum board ceilings to be painted P-4 unless noted otherwise.

F. Ceiling height as noted on plan.

GENERAL RCP NOTES

N

(BID ITEM #2- Delete Lockers)

(BID ITEM #2- Delete Lockers)

UP

UP

UP UP

UP

UP

DN

UP

UP

DN

UP

UP

UP

DN

UP

UP

UP

DN

UP

DN

UPDN

UP

DN

UP

UP

UP

UP

Toilet-Male

A004C

Toilet-Female

A004E

Existing Locker Count: 6 (Men) + 6 (women) = 12 New Locker Count: 8 (Unisex) Half-height

HAC

A004D

Locker Alcove

A004G

A401

A

A

A401

A401

A401

A

A

A

A401

A401

A401

A401

S1.0

S2.0S1.0

S1.0

S2.0

S2.0

S1.0

S2.03

/4

10' - 5"

7' - 1 5/8"

/2

4' - 4"

/4

3' - 0"

Corridor

C*B*2

/8

S1.0

3' - 0"

3' - 3 3/4" 7' - 1 1/4"

A004C A004E

S3.0

S3.0

A601

9.35

9.35

9"

S2.0

S2.0

12.1012.10

12.10

23.01

A311

E1.0

7'-8"

7'-8"

7'-8"

Toilet-Male

A004C

HAC

A004D

Toilet-Female

A004E

Locker Alcove

A004G

Corridor

C*B*2

7'-7"

7'-7"

9.29

7'-7"

9.29

ACT-2

ACT

ACT-2

9.28

9.28

9.28

GYP

GYP

9.25

ACT-2

7'-8"

ACT

7'-8"

Toilet-Male

A004C

HAC

A004D

Locker Alcove

A004G

Toilet-Female

A004E

Corridor

C*B*2

PT-2

PT-2

RB-1

RB-1

PTB-1

PTB-1

?CG-1

CG-1

CG-1

CG-1CG-1

PT-1

Toilet-Male

A004C

HAC

A004D

Toilet-Female

A004E

Locker Alcove

A004G

Corridor

C*B*2

PT-1

VCT-1

VCT

PHASE 2

AREA OF WORK

A004C - Men Toilet A004D - H.A.C.

A004E - Women Toilet

DEMOLITION LEGEND

Block wall to be demolished

Existing wall to remain

Door and frame to be demolished

A004C

A004D

A004E

A004F 2.592.61

2.57

2.60

2.55

2.57

2.59

2.55

2.60

2.16

2.10

2.10

Corridor

C*B*2

2.58 2.58

1.038.05

2.07 2.07

2.72

2.53 2.53

2.042.04

2.072.07

2.07

2.072.07

2.07

2.54

2.72

2.65

2.72

2.06

2.08

2.52 2.52 9.31

2.71

2.642.64

REFLECTED CEILING PLAN LEGEND

Recessed downlight fixture

Supply Air Diffuser

Return Air Grille

2' x 4' light fixture

2' x 2' acoustical tile ceiling

Gypsum board / portland cement plaster ceiling / soffit - painted

Chain-hung light fixture

Exhaust Grille

2' x 2' light fixture

JASON

H.

ROSS

2118221

IO

HO

FOET

A T

S

R E G I S

E T

R

ED RA

C H

TI

E C T

VA Project No.

RDC/JPA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

/2

/2

:0

:0

P

M

VA Cincinnati Bathroom Deficiency Remediation

03/24/2023

NEW WORK PLAN - PHASE 2

A102

JWKR

539-22-207

Cincinnati, OH

Kristina Amin

100% Bid Documents 22034.00

N Scale: 1/4" = 1'-0"2

PHASE 2 NEW WORK PLAN - Basement A004C, A004D, A004E

N Scale: 1/4" = 1'-0"3

PHASE 2 NEW WORK RCP - Basement A004C, A004D, A004E

N Scale: 1/4" = 1'-0"4

PHASE 2 WALL FINISH PLAN -Basement A004C, A004D, A004E

N Scale: 1/4" = 1'-0"5

PHASE 2 FLOOR FINISH PLAN - Basement A004C, A004D, A004E

KEYPLAN - Basement

N Scale: 1/4" = 1'-0"1

PHASE 2 DEMOLITION PLAN - Basement A004C, A004D, A004E

1.03 Temporary Construction Barrier.

2.04 Existing floor finish to remain. Protect in place during construction.

2.06 Existing suspended ceiling system, fixtures, and devices to remain.

2.07 Demolish existing block wall from floor to deck.

2.08 Remove existing half height wall tile.

2.10 Remove existing toilet partitions.

2.16 Existing to remain.

2.52 Remove existing wall covering.

2.53 Remove existing ceramic tile flooring and coved base. Prep floor to receive new finishes.

2.54 Remove existing VCT floor finish and rubber base. Prep floor to receive new finishes.

2.55 Remove floor mounted plumbing fixture. Repair floor penetrations. Prep floor to receive new finishes.

2.57 Remove existing metal lockers.

2.58 Remove existing shower surround and shower base. Prepare subfloor for new schedule finish and base.

2.59 Remove wall-mounted plumbing fixture.

2.60 Remove and salvage all existing wall-mounted grab bars and toilet room accessories.

2.61 Remove existing mirror.

2.64 Remove and salvage existing acoustical ceiling tile and grid, light fixtures, and other ceiling mounted devices for reinstallation following above-ceiling work.

2.65 Remove and salvage existing Shower Mixing Valve for reinstallation in new location.

2.71 Remove existing Gyp ceiling.

2.72 Remove existing ACT ceiling.

8.05 Temporary construction entrance door and frame with locking hardware.

9.25 ACT ceiling system.

9.28 Gypsum board bulkhead. See Detail.

9.29 Gypsum board ceiling.

9.31 Ceramic [porcelian] wall tile.

9.35 Solid Surface sill.

12.10 Locker room bench wall mounted.

23.01 New exhaust louver location. See Mechanical Drawings.

A. Remove all existing partitions shown with dashed line. Repair wall and floor finishes to match adjacent surfaces at areas of removal or scheduled new surfaces as required.

B. See Plumbing, HVAC and Electrical Drawings for removal work associated with those trades.

C. Computer and communication cables and/or other wiring, piping, tubing, etc.

serving other areas and functions located above ceiling or in walls of area to be remodeled shall be maintained during demolition/construction process.

D. Repair existing walls to match adjacent undisturbed wall where cabinets, countertops, etc. are shown to be removed.

E. Prepare walls and floor slabs as required to receive new fininsh materials where existing finish is indicated to be removed.

F. Prepare existing floor surface throughout the entire area of demolition and construction for new covering. Pour cementitious topping to fill voids, feather all edges to match adjacent floor elevations and correct low areas. Review and coordinate new floor drain locations and any floor slopes prior to slab prep.

G. Protect existing structure, adjacent windows, doors, and other building elements during demolition.

H. Provide tile substrate as follows: All shower stalls and tiled surfaces will receive Cementious backer units. All Bathrooms, Restrooms, HAC will receive Water-resistant gyp. board.

KEYNOTES

GENERAL DEMO NOTES

GENERAL NOTES

A. All dimensions are taken to face of gypsum wallboard or unit masonry.

B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.

C. All wood blocking to be fire retardent treated.

D. First floor level 100'-0" equals 728'-0".

E. All partitions shall be type 'S1.0' unless noted otherwise.

A. All wood blocking shall be fire retardant.

B. Light fixtures, sprinkler heads, speakers, and HVAC devices shall be located as close as possible to the center of acoustical ceiling panels.

Confirm any deviation from this with the Project Engineer.

C. See P, M, E and FP drawings for additional information regarding final information and quantites of fixtures/devices to be installed in ceiling.

D. All ACT ceilings in bathrooms to be Clean Room Type Washable ACT system.

D. See Electrical Drawings for lighting specifications.

E. All gypsum board ceilings to be painted P-4 unless noted otherwise.

F. Ceiling height as noted on plan.

GENERAL RCP NOTES

N

(BID ITEM #4 - Delete Phase 2 Work)(BID ITEM #2- Delete Lockers) (BID ITEM #4 - Delete Phase 2 Work)

(BID ITEM #4 - Delete Phase 2 Work)

(BID ITEM #4 - Delete Phase 2 Work)

(BID ITEM #4 - Delete Phase 2 Work) (BID ITEM #2- Delete Lockers)

UP

UP

UP UP

UP

UP

DN

UP

UP

DN

UP

UP

UP

DN

UP

UP

UP

DN

UP

DN

UPDN

UP

DN

UP

UP

UP

UP

A402

D

Toilet-Unisex

B008

S2.0-SS2.0-SS2.0-S

2' - 4"5' - 2 1/8" 3' - 0"

S1.0 S2.0 S1.0

S2.0

S2.0

/2

B008

S3.0 9.35

8'-0"

8'-0"

Toilet-Male

B010

7'-11"

7'-0"

8'-0"

7'-11"

9.29

ACT-2

ACT-2

ACT-2

9.28

GYP

A601

9.22

9.28

Toilet-Unisex

B008

PT-2

PTB-1

RB-1

P-1

Toilet-Unisex

B008

PT-1

VCT

Toilet-Male

B010

PT-1

VCT-1

VCT-1

VCT

Toilet-Male

B010

PT-2

PTB-1

CG-1CG-1

RB-1P-1

P-1

RB-1

PTB-1

P-1

PHASE 3

AREA OF WORK

B008 - Unisex Toilet B010 - Women Toilet

DEMOLITION LEGEND

Block wall to be demolished

Existing wall to remain

Door and frame to be demolished

B010

2.55

2.61

2.612.612.61

2.60

2.16

2.59 2.53

2.55

2.56

2.502.502.502.50

2.102.10

1.03

8.05

2.072.072.07

2.72

2.10

9.319.319.31

A601

B008

2.55

2.60

2.582.58 2.59

1.038.05

2.532.53

2.07

2.72

2.07 9.31

Toilet-Male

B010

A402

E

S1.0

S1.0

S2.0

S1.0

S1.0

S2.0S2.0 S2.0

S2.0

S2.0

10'-11 3/8"

4' - 3"

/8

5' - 6"

5' - 4 3/8"

2' - 6 1/8"2' - 6"3' - 0"

1' - 0 3/8"

TP

B010

Existing Locker Count: 0 (Men) + 0 (Women) = 0 New Locker Count: 6 (Unisex) Half-height

S2.0

S1.0

S2.0

S2.0

S2.0

S3.0

S3.0

S3.0

S3.0

A601

9.35

12.10

8'-0"

Toilet-Unisex

B008

7'-11"

9.29

ACT-2

GYP

9.284

A601

REFLECTED CEILING PLAN LEGEND

Recessed downlight fixture

Supply Air Diffuser

Return Air Grille

2' x 4' light fixture

2' x 2' acoustical tile ceiling

Gypsum board / portland cement plaster ceiling / soffit - painted

Chain-hung light fixture

Exhaust Grille

2' x 2' light fixture

JASON

H.

ROSS

2118221

IO

HO

FOET

A T

S

R E G I S

E T

R

ED RA

C H

TI

E C T

VA Project No.

RDC/JPA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

/2

/2

:0

:1

P

M

VA Cincinnati Bathroom Deficiency Remediation

03/24/2023

NEW WORK PLAN - PHASE 3

A103

JWKR

539-22-207

Cincinnati, OH

Kristina Amin

100% Bid Documents 22034.00

N Scale: 1/4" = 1'-0"2 PHASE 3 NEW WORK PLAN - Basement B008, B010

N Scale: 1/4" = 1'-0"3 PHASE 3 NEW WORK RCP - Basement B008, B010

N Scale: 1/4" = 1'-0"4 PHASE 3 WALL FINISH PLAN - Basement B008, B010

N Scale: 1/4" = 1'-0"5 PHASE 3 FLOOR FINISH PLAN - Basement B008, B010

KEYPLAN - Basement

N Scale: 1/4" = 1'-0"1 PHASE 3 DEMOLITION PLAN - Basement B008, B010

1.03 Temporary Construction Barrier.

2.07 Demolish existing block wall from floor to deck.

2.10 Remove existing toilet partitions.

2.16 Existing to remain.

2.50 Remove existing masonry block walls.

2.53 Remove existing ceramic tile flooring and coved base. Prep floor to receive new finishes.

2.55 Remove floor mounted plumbing fixture. Repair floor penetrations. Prep floor to receive new finishes.

2.56 Remove existing shower base. Prepare subfloor for new schedule finish and base.

2.58 Remove existing shower surround and shower base. Prepare subfloor for new schedule finish and base.

2.59 Remove wall-mounted plumbing fixture.

2.60 Remove and salvage all existing wall-mounted grab bars and toilet room accessories.

2.61 Remove existing mirror.

2.72 Remove existing ACT ceiling.

8.05 Temporary construction entrance door and frame with locking hardware.

9.22 Gypsum board header. See Detail.

9.28 Gypsum board bulkhead. See Detail.

9.29 Gypsum board ceiling.

9.31 Ceramic [porcelian] wall tile.

9.35 Solid Surface sill.

12.10 Locker room bench wall mounted.

A. Remove all existing partitions shown with dashed line. Repair wall and floor finishes to match adjacent surfaces at areas of removal or scheduled new surfaces as required.

B. See Plumbing, HVAC and Electrical Drawings for removal work associated with those trades.

C. Computer and communication cables and/or other wiring, piping, tubing, etc.

serving other areas and functions located above ceiling or in walls of area to be remodeled shall be maintained during demolition/construction process.

D. Repair existing walls to match adjacent undisturbed wall where cabinets, countertops, etc. are shown to be removed.

E. Prepare walls and floor slabs as required to receive new fininsh materials where existing finish is indicated to be removed.

F. Prepare existing floor surface throughout the entire area of demolition and construction for new covering. Pour cementitious topping to fill voids, feather all edges to match adjacent floor elevations and correct low areas. Review and coordinate new floor drain locations and any floor slopes prior to slab prep.

G. Protect existing structure, adjacent windows, doors, and other building elements during demolition.

H. Provide tile substrate as follows: All shower stalls and tiled surfaces will receive Cementious backer units. All Bathrooms, Restrooms, HAC will receive Water-resistant gyp. board.

KEYNOTES

GENERAL DEMO NOTES

GENERAL NOTES

A. All dimensions are taken to face of gypsum wallboard or unit masonry.

B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.

C. All wood blocking to be fire retardent treated.

D. First floor level 100'-0" equals 728'-0".

E. All partitions shall be type 'S1.0' unless noted otherwise.

A. All wood blocking shall be fire retardant.

B. Light fixtures, sprinkler heads, speakers, and HVAC devices shall be located as close as possible to the center of acoustical ceiling panels.

Confirm any deviation from this with the Project Engineer.

C. See P, M, E and FP drawings for additional information regarding final information and quantites of fixtures/devices to be installed in ceiling.

D. All ACT ceilings in bathrooms to be Clean Room Type Washable ACT system.

D. See Electrical Drawings for lighting specifications.

E. All gypsum board ceilings to be painted P-4 unless noted otherwise.

F. Ceiling height as noted on plan.

GENERAL RCP NOTES

FINISH LEGEND

FINISH CATEGORY CODE FINISH TYPE MANUFACTURER PRODUCT / COLOR COMMENTS

06 41 16 PLASTIC LAMINATE CLAD ARCHITECTURAL CABINETS

06 41 16 PLASTIC LAMINATE CLAD

ARCHITECTURAL CABINETS

PL-1 PLASTIC LAMINATE WILSONART HD Laminate, Ashbee Oak #17000K-57, Aligned Texture, AEON Scratch Resistant

Bathroom Aprons

09 30 13 CERAMIC PORCELAINTILING

09 30 13 CERAMIC PORCELAINTILING PT-1 PORCELAIN TILE CROSSVILLE Empire #VS75 White White UN Unpolished, 12x24 Grout 02 Pewter

09 30 13 CERAMIC PORCELAINTILING PT-2 PORCELAIN TILE CROSSVILLE Empire #VS75 Cadet White White PO Polished, 12x24 Grout 01 Alabaster

09 30 13 CERAMIC PORCELAINTILING PTB-1 PORCELAIN TILE

BASE

CROSSVILLE Empire #VS75 White White UN Unpolished, 6x12 Grout 02 Pewter

09 51 00 ACOUSTICAL CEILING

09 51 00 ACOUSTICAL CEILING ACT-1 CEILING FINISHES ARMSTRONG Ultima Part 1910, Size 24” x 24”, Color: White Acoustic Ceiling Tile 24 x 24

09 51 00 ACOUSTICAL CEILING ACT-2 CEILING FINISHES ARMSTRONG Clean Room VL 868B, 24" x 24"x 5/8"; White Grid

09 65 13 RESILIENT BASE AND ACCESSORIES

09 65 13 RESILIENT BASE AND

ACCESSORIES

RB-1 RUBBER BASE JOHNSONITE Rubber Cove Base 6", Color: #80 Fawn

09 65 13 RESILIENT BASE AND

ACCESSORIES

VCT-1 RESILIENT

FLOORING

TBD New Flooring Match the Existing

09 91 00 PAINTING

09 91 00 PAINTING P-1 INTERIOR PAINT BENJAMIN MOORE TBD Semi Gloss - All Walls To Be Painted P-1 Unless Noted Otherwise.

09 91 00 PAINTING P-2 PAINT(DOOR

FRAMES)

BENJAMIN MOORE TBD High Gloss Enamel - Door Frames

10 21 13 TOILET COMPARTMENTS

10 21 13 TOILET COMPARTMENTS TP-1 TOILET PARTITION TBD Stainless Steel Toilet Partitions

10 26 00 WALL AND DOOR PROTECTION

10 26 00 WALL AND DOOR

PROTECTION

CG-1 CORNER GAURD TBD Stainless Steel Match the Existing

10 26 00 WALL AND DOOR

PROTECTION

HR-1 HAND RAIL INPRO Match the Existing

12 36 61.16 SOLID SURFACING COUNTERTOPS

12 36 61.16 SOLID SURFACING

COUNTERTOPS

SS-1 SOLID SURFACE WILSONART Hot Stone #9201GS Bathroom Countertops N

(BID ITEM #3- Delete Rm# B008 Work)

(BID ITEM #2- Delete Lockers)

(BID ITEM #3- Delete Rm# B008 Work)

(BID ITEM #3- Delete Rm# B008 Work)

(BID ITEM #3- Delete Rm# B008 Work)

(BID ITEM #3- Delete Rm# B008 Work)

(BID ITEM #2- Delete Lockers)

S1.0

4 7/8"

9.219.21

9.02

9.80

7.82

7.82

STRUCTURE ABOVE

FIN. CEILING

FLOOR SLAB

9.04

S1.1

9.219.21

9.03

9.80

7.82

7.82

7 1/4"

9.04

S2.0

9.02

9.02

7.82

7.82

4 1/4"

9.80

@ INTERIOR WALL

LOCATIONS

9.21

9.04

S2.0-S

NON-RATED

SMOKE PARTITION

9.21

5.06

9.80

7.82

7.82

4 1/4"

9.04

T1.0

9.21

9.02

9.80

4 1/4"

9.16

1-HR RATED

FIRE BARRIER

U.L. #U465

S3.0

5/8"

9.23

E1.0

4.13

4 1/2"

4.16

7.12

7 5/8"

1' - 1 1/8"

FLOOR SLAB

E1.0

5.05

5.04

23.02

23.01

4.17

4.17

2.49

JASON

H.

ROSS

2118221

IO

HO

FOET

A T

S

R E G I S

E T

R

ED RA

C H

TI

E C T

VA Project No.

RDC/JPA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

/2

/2

:0

:1

P

M

VA Cincinnati Bathroom Deficiency Remediation

03/24/2023

WALL SECTIONS

A311

JWKR

539-22-207

Cincinnati, OH

Kristina Amin

100% Bid Documents 22034.00

2.49 Remove existing 4-1/2" thick stone panel (Approx. size 30"x30") and 8" CMU.

4.13 8" concrete masonry unit.

4.16 Stone Veneer

4.17 Masonry tie.

5.04 Steel lintel.

5.05 Steel lintel plate.

5.06 3-5/8" cold formed metal framing @ 16" O.C.

7.12 Rigid thermal wall insulation.

7.82 Continuous acoustic sealant @ non-rated walls / fire-rated sealant @ rated walls each side.

9.02 3 5/8" non-structural metal framing @ 16" o.c.

9.03 6" non-structural metal framing @ 16" o.c.

9.04 Deflection track.

9.16 Plastic sheeting

9.21 5/8" Type 'X" gypsum board. Painted finish.

9.23 5/8" Type "X" gypsum board laminated to existing wall face.

Extend to above finished ceiling.

9.80 Acoustic insulation

23.01 New exhaust louver location. See Mechanical Drawings.

23.02 Duct. See Mechanical Drawings.

SECTION NOTES

N.T.S.Scale:

Exterior Louver

X

X

Toilet Accessory

Equipment

Signage

Keynote

Material Finish

SYMBOL LEGEND

A

A401

A401

A401

A

A

A

A401

A401

A401

A401

Toilet-Male

A004C

Toilet-Female

A004EHAC

A004D

Locker Alcove

A004G

Corridor

C*B*2

K

I

C

LA

J

22.06

22.06

C

L A

M

I

10.51 B

B

A601

A311

PT-2

O I

K

PL-1SS-1

C

B8 2'-9"

H

C

G

A

26.01

PTB-1

P-1

N

C

A

H

10.12

9.35

12.10

1' - 10"

" 3

22.05 J

L

B

A

P-1 PT-2

C

N A

CC

10.12

22.05

PL-1

PT-2

SS-1

I

M

O

2'-9"

B8

H

C

10.12

G

A

26.01

12.10

2' - 6"1

A311

A

B

L

PTB-1

P-1P-1

10.51

P-1

10.53

10.52

10.52

12.10

PTB-1

P-1

1' - 10"

P-1

RB-1

HR-1

P-1 P-1A

HR-1

A CG-1CG-1

CG-1

RB-1 RB-1

ACG-1

4' - 4"

P-1

A

10.53

10.52 1' - 10" 12.10

RB-1

10.54

A401

A

A401

A

A

A

A401

A401

A

A401

A

A401

Toilet-Male

A026

Toilet-Female

A026A

Locker Room

A026B

A401

I

M

I

I

K

K

A B

C

B CA

JJ

JJ

22.06

L

L

L

22.06

22.06

10.03

10.0310.03

10.03

AC

PTB-1

P-1

M

P-1

I

PTB-1

PT-2

PTB-1

PL-1

SS-1

O

2'-9"

B8

26.01

PTB-1

B

A

L

10.11

PT-2

C

I

O

PTB-1

P-1

PL-1

SS-1

I

K

B8

4'-0"

P-1

H

C

G

A

26.01

C

PT-2

P-1 N

PTB-1

A

C

H

10.12

22.05

P-1P-1

PTB-1

B

A

PL-1

SS-1

J

B8

2'-6"

10.11

O

26.01

P-1 P-1

10.51

10.53

10.52

P-1

10.51

10.53

10.5210.52

P-1

10.51

10.53

10.52

12.10

10.53

10.51

10.52

10.54

A

A401

H.A.C.

A025

22.04

10.04

22.04

10.04

10.02

PT-2

PTB-1

22.04

PL-1

W1

2'-0"

PT-2

JASON

H.

ROSS

2118221

IO

HO

FOET

A T

S

R E G I S

E T

R

ED RA

C H

TI

E C T

VA Project No.

RDC/JPA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

/2

/2

:0

:3

P

M

VA Cincinnati Bathroom Deficiency Remediation

03/24/2023

INTERIOR ELEVATIONS

A401

BMKR

539-22-207

Cincinnati, OH

Kristina Amin

100% Bid Documents 22034.00

A. See sheet A101 detail 5/ A102 detail 5/ A103 detail 5 for Floor Finish Plan.

B. See sheet A511 for Casework Details.

C. See sheet A103 for Finish Materials Legend.

D. Provide tile substrate as follows: All shower stalls and bathroom walls will receive Cementious backer units. All Bathrooms, Restrooms, HAC will receive Water-resistant gyp. board.

9.35 Solid Surface sill.

10.02 Utility cabinet.

10.03 Surface mounted garment hook

10.04 Mop and broom holder.

10.11 Toilet partition overhead bracing.

10.12 Solid surface standard shower enclosure system.

10.51 Metal lockers match the existing

10.52 Metal trim panel. Paint to match lockers.

10.53 Sloped top by locker manufacturer.

10.54 Adjustable leveling feet.

12.10 Locker room bench wall mounted.

22.04 Mop sink

22.05 Shower controls.

22.06 Undermount solid surface sink bowl.

26.01 Light fixture. See Electrical Drawings.

ELEVATION NOTES

GENERAL INT. ELEVATION NOTES

A2 13456

B1314151617

Scale: 1/4" = 1'-0"

PHASE 2 - Basement A004C, A004D, A004E

Scale: 1/4" = 1'-0"

PHASE 1 - Basement A026, A026A, A026B

2122232425

Scale: 1/4" = 1'-0"

Basement A025

C2627

SIGNAGE SCHEDULE

Type Mark Count

MOUNTING

HEIGHT

A 9 51" A.F.F. TO

BOTTOM

(BID ITEM #2- Delete Lockers)

(BID ITEM #4 - Delete Phase 2 Work)(BID ITEM #2- Delete Lockers)

X

Toilet Accessory

Equipment

Signage

Keynote

Material Finish

SYMBOL LEGEND

Toilet-Unisex

B008

A

A402

A

A402

22.06

G

C

A

10.12

L

A

B

I

M

A

A402

A402

A

Toilet-Male

B010

BC

L

KI 22.06 10.51

10.03

GC A

10.12

10.01

10.01

10.01

A601

B8 2'-6"

PL-1

P-1

O

SS-1

M

26.01

PTB-1

PT-2

C

P-1

H

C

A

10.12

A

B

L

PTB-1

10.03

H

C

P-1 P-1P-1

G

A

10.12

PTB-1

P-1P-1

10.51

A

10.52

10.01

10.53

RB-1RB-1

" 3

PT-2

PL-1 SS-1

P-1

C

O

B8 2'-6"

H

C

G

A

C

10.12 10.1126.01

22.05

P-1

2.16

PTB-1

3' - 6"

12.10

PTB-1

1'-0"

3'-3"

P-1

PTB-1

B

A

L

1' - 0"

3' - 3"

Note: Flush valve located on accessible side

6"

B

A

M

IN

D

C

Note:

Beginning of reflective surface

MIN.

7"

O

T o D is p e n s e r

O p e n in g

A D

A /A

B A

A S

A c c e s s ib le

T o

O p e ra b le

M e c h a n is m

I

N

F

A

/8

H

E

M

K

J L

1'-6"

D

8"

"m a x m in

Shower control space

2' - 3"max

Shower control space

3' - 0" 3' - 0"

1' - 6"

TILE TO PAINTED GYP. TILE COVE-SHAPED PROFILETILE OUTSIDE CORNER EDGE PROFILE

9.31

9.31

9.67

9.31

9.66

9.31

9.33

9.65 9.33

9.52

9.68

9.36

9.38

9.37

JASON

H.

ROSS

2118221

IO

HO

FOET

A T

S

R E G I S

E T

R

ED RA

C H

TI

E C T

VA Project No.

RDC/JPA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

/2

/2

:0

:4

P

M

VA Cincinnati Bathroom Deficiency Remediation

03/24/2023

INTERIOR ELEVATIONS

A402

BMKR

539-22-207

Cincinnati, OH

Kristina Amin

100% Bid Documents 22034.00

TOILET ACCESSORIES SCHEDULE

MARK ITEM JSN #

PROVIDED

BY

INSTALLED

BY

O W

N E

R

C O

N T

R A

C T

O R

O W

N E

R

C O

N T

R A

C T

O R

A GRAB BAR 18" LENGTH B-6806 X 18 X X

B GRAB BAR 42" LENGTH B-6806 X 42 X X

C GRAB BAR 36" LENGTH B-6806 X 36 X X

G Shower Seat X X

H Shower Curtain Rod X X

I Soap Dispenser BY OWNER X X

J Sanitary Napkin Dispenser BY OWNER X X

K Paper Towel Dispenser BY OWNER X X

L Toilet Tissue Dispenser B-2888 X X

M Paper Towel-Waste Combo-Partial Recess X X

N Robe Hook X X

O Mirror - 24" x 36" B-290 2436 X X

A. See sheet A101 detail 5/ A102 detail 5/ A103 detail 5 for Floor Finish Plan.

B. See sheet A511 for Casework Details.

C. See sheet A103 for Finish Materials Legend.

D. Provide tile substrate as follows: All shower stalls and bathroom walls will receive Cementious backer units. All Bathrooms, Restrooms, HAC will receive Water-resistant gyp. board.

ELEVATION NOTES

GENERAL INT. ELEVATION NOTES

Scale: 1/4" = 1'-0"

PHASE 3 - Basement B008

D

E

Scale: 1/4" = 1'-0"

PHASE 3 - Basement B010

2.16 Existing to remain.

9.31 Ceramic [porcelian] wall tile.

9.33 Porcelian floor tile.

9.36 .0625" Silicone Adhesive

9.37 Full mortar bed (min. 1/8").

9.38 Waterproofing / crack isolation membrane.

9.52 Existing VCT.

9.65 Anodized aluminum type edge strips embedded in tile setting bed shall be used at all horizontal unfinished edges of wall tile and base. Size and profile to be used with appropriate tile thickness.

9.66 Anodized aluminum type edge strips embedded in tile setting bed shall be used at all floor to wall tile intersections. Size and profile to be consistent with tile thickness.

9.67 Anodized aluminum type edge strips embedded in tile setting bed shall be used at all exterior corners. Size and profile to be consistent with tile thickness.

9.68 Metal [stainless steel] edge trim.

10.01 Corner protection.

10.03 Surface mounted garment hook

10.11 Toilet partition overhead bracing.

10.12 Solid surface standard shower enclosure system.

10.51 Metal lockers match the existing

10.52 Metal trim panel. Paint to match lockers.

10.53 Sloped top by locker manufacturer.

12.10 Locker room bench wall mounted.

22.05 Shower controls.

22.06 Undermount solid surface sink bowl.

26.01 Light fixture. See Electrical Drawings.

01_Typical Mounting Heights - Toilet Accessories

Tile Transitions Flooring Transition VCT - PT

(BID ITEM #2- Delete Lockers)

(BID ITEM #3- Delete Rm# B008 Work)

SEE PLAN

1/2" 1/2"

H1 J1

8.02

9.21

9.80

8.02

9.09

9.21

9.80 8.04

S1

9.08

7.82 7.82 1/2" 1/2"

2"

SEE

SCHED. 2"

S E

E S

C H

E D

U L E

SEE SCHED.

S E

E S

C H

E D

U L E

F

9.30

9.18

9.29

9.02

Varies

9.02

9.309.30

9.21

9.18

Drywall to extend 6" above finished ceiling.

/8

/8

Slope 1/4"-1/8" : 12" max

9.34

9.35

9.34

9.33

9.28

9.30

26.01

9.34

9.02

9.29

22.05

/2

Shower controls to be min 1-1/2" above grab bars, not to exceed 48" A.F.F.

A

C

H

Controls 27" max

A601

Sim

9.34

9.39

9.36

9.02

Air Gap

Gap 3/16"

22.08

7.01

7.02

9.33

9.35

9.55

9.37

22.09

/2

M

A X

9.42

B8

Sink

2'-1"

/4

/4

1"

11" 5" 8"

12.27

12.20

22.06

12.19

W1

1'-2" 1"

26.01

12.29

12.30

12.31

12.22

12.21

9.27

JASON

H.

ROSS

2118221

IO

HO

FOET

A T

S

R E G I S

E T

R

ED RA

C H

TI

E C T

VA Project No.

RDC/JPA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

/2

/2

:0

:4

P

M

VA Cincinnati Bathroom Deficiency Remediation

03/24/2023

SCHEDULES, SECTIONS & DETAILS

A601

JWKR

539-22-207

Cincinnati, OH

Kristina Amin

100% Bid Documents 22034.00

DOOR SCHEDULE

DOOR

DOOR DESCRIPTION FRAME DESCRIPTION

Sill Detail

FIRE

RATING

HDWE

SET REMARKSTYPE MAT'L

SIZE

TYPE MAT'L HEAD JAMB# W H T

A004C F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H-1 J-1 S-1 N/A HW-2

A004E F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H-1 J-1 S-1 N/A HW-2

A025 F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H-1 J-1 S-1 N/A HW-1 Knock-down frame required

A026 F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H-1 J-1 S-1 N/A HW-4

A026A F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H-1 J-1 S-1 N/A HW-4

B008 F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H-1 J-1 S-1 N/A HW-2

B010 F WD 1 3'-0" 7'-0" 1 3/4" 1 HM H-1 J-1 S-1 N/A HW-3

7.01 Waterproofing membrane.

7.02 Extend waterproof membrane past shower pan. Top of

membrane must be above top of drain.

7.82 Continuous acoustic sealant @ non-rated walls / fire-rated sealant @ rated walls each side.

8.02 Temporary hollow metal frame.

8.04 Hospital stops @ all interior hollow metal frames.

9.02 3 5/8" non-structural metal framing @ 16" o.c.

9.08 Metal framing box header.

9.09 Double metal framing at jambs, typ.

9.18 5/8" Type "X" gypsum board.

9.21 5/8" Type 'X" gypsum board. Painted finish.

9.27 Gypsum board soffit.

9.28 Gypsum board bulkhead. See Detail.

9.29 Gypsum board ceiling.

9.30 Clean Room type washable ACT system.

9.33 Porcelian floor tile.

9.34 3/4" Solid Surface.

9.35 Solid Surface sill.

9.36 .0625" Silicone Adhesive

9.37 Full mortar bed (min. 1/8").

9.39 Cementitious Backer Board

9.42 Add tapered floor fill to ensure 1/2" maximum transition between finished surfaces.

9.55 Existing Concrete Slab

9.80 Acoustic insulation

12.19 Integral solid surface backsplash.

12.20 Solid surface material over 3/4" plywood, with 1/4" eased edge.

12.21 Plastic laminate over 3/4" particle board.

12.22 Adjustable shelf. Plastic laminate over 3/4" particle board.

12.27 Removable panel with concealed fasteners: Plastic laminate over 3/4" plywood.

12.29 4" wire pull. [Recessed pull.]

12.30 Self-latching, key-operated lock.

12.31 Concealed hinge.

22.05 Shower controls.

22.06 Undermount solid surface sink bowl.

22.08 Shower drain. See Plumbing Drawings.

22.09 Shower Receptor/Base.

26.01 Light fixture. See Electrical Drawings.

N.T.S.Scale:

H.M. Frame Details

N.T.S.Scale:

H.M. Frame Types N.T.S.Scale:

Door Types

DETAIL NOTES

N.T.S.Scale:

Typical Bulkhead Detail N.T.S.Scale:

Typical Header Detail N.T.S.Scale:

Typical Shower Detail Scale: 1 1/2" = 1'-0"7 Shower Waterproofing and Drain

A. See interior elevations on sheet A401-A404 for further information.

GENERAL CASEWORK NOTES

N.T.S.Scale:

Casework Sections N.T.S.Scale:

Casework Sections

ABBREVIATIONS

AC - AIR COMPRESSOR

ACC - ACCESS

AD - ACCESS DOOR

ADB - ACID DILUTION BASIN

ADJ - ADJUSTABLE

AFF - ABOVE FINISHED FLOOR

AFG - ABOVE FINISHED GRADE

ALT - ALTERNATE

AP - ACCESS PANEL

APPROX - APPROXIMATE

ARCH - ARCHITECT OR ARCHITECTURAL

ASSY - ASSEMBLY

BFP - BACKFLOW PREVENTER

BLDG - BUILDING

BOB - BOTTOM OF BEAM

BOD - BOTTOM OF DUCT

BOE - BOTTOM OF EQUIPMENT

BOF - BOTTOM OF FOOTING

BOG - BOTTOM OF GRILLE

BOP - BOTTOM OF PIPE

BOT - BOTTOM

BTWN - BETWEEN

CA - COMPRESSED AIR

CFCI - CONTRACTOR FURNISHED CONTRACTOR

INSTALLED

CLG - CEILING

CONN - CONNECT OR CONNECTION

CONTR - CONTRACTOR

COR - CONTRACTING OFFICER'S REPRESENTATIVE

CORR - CORRIDOR

CTR - CENTER

CWS - COMBINATION WATER SERVICE

D - DEPTH

DET - DETAIL

DIA - DIAMETER

DIM - DIMENSION

DN - DOWN

DS - SPRINKLER (DRY)

DWG - DRAWING

EA - EACH

EC - ELECTRICAL (DIVISION 26)

EJ - EXPANSION JOINT

ELEC - ELECTRICAL

ELEV - ELEVATOR

EQ - EQUAL

EQUIP - EQUIPMENT

ETR - EXISTING TO REMAIN

EQS - EQUIPMENT SUPPLIER

EXP - EXPANSION

EXT - EXTERIOR

EX - EXISTING

F - FIRE SUPPRESSION (STANDPIPE/SPRINKLER MAIN)

FCE - FIRE CONTROL EQUIPMENT

FCO - FLOOR CLEANOUT

FD - FLOOR DRAIN

FDC - FIRE DEPARTMENT CONNECTION

FDV - FIRE DEPARTMENT VALVE

FF - FINISHED FLOOR ELEVATION

FHC - FIRE HOSE CABINET

FLR - FLOOR

FPM - FEET PER MINUTE

FR - FIRE RISER

FS - FIRE SERVICE

FSC - FIRE SUPPRESSION (DIVISION 21)

FT - FEET

FTG - FOOTING

GA - GAUGE

GAL - GALLON

GALV - GALVANIZED

GC - GENERAL TRADES

GPM - GALLONS PER MINUTE

HC - HVAC (DIVISION 23)

HD - HUB DRAIN

HP - HORSEPOWER OR HIGH POINT

HR - HOSE REEL

HT - HEAT TRACE

HVAC - HEATING, VENTILATING, AND AIR CONDITIONING

ID - INSIDE DIAMETER

INV - INVERT ELEVATION

IN - INCHES

JS - JANITOR SINK

L - LENGTH

LBS - POUNDS

MAX - MAXIMUM

MB - MOP BASIN

MC - MECHANICAL (DIVISION 23)

MEZZ - MEZZANINE

MFR - MANUFACTURER

MIN - MINIMUM

MISC - MISCELLANEOUS

MTD - MOUNTED

MTG - MOUNTING

N/C - NORMALLY CLOSED

NIC - NOT IN CONTRACT

N/O - NORMALLY OPEN

NOM - NOMINAL

NPT - NATIONAL PIPE THREAD

NTS - NOT TO SCALE

OA - OUTDOOR AIR

OD - OUTSIDE DIAMETER

OFCI - OWNER FURNISHED CONTRACTOR

INSTALLED

OFOI - OWNER FURNISHED OWNER INSTALLED

PC - PLUMBING (DIVISION 22)

OR PUMPED CONDENSATE RETURN

PIV - POST INDICATOR VALVE

PLBG - PLUMBING

PS - PRE-ACTION/DELUGE SPRINKLER

PRESS - PRESSURE

PRV - PRESSURE REGULATING VALVE

PSF - POUNDS PER SQUARE FOOT

PSI - POUNDS PER SQUARE INCH

PSV - PRESSURE SUSTAINING VALVE

PSIG - POUNDS PER SQUARE INCH GAUGE

RAD - RADIUS

REC - RECESSED

REQD - REQUIRED

RI - ROUGH IN

RPM - REVOLUTIONS PER MINUTE

S - SPRINKLER (WET)

SCH - SCHEDULE

SD - SPRINKLER DRAIN

SHT - SHEET

SK - SINK

SPEC - SPECIFICATIONS

SQ - SQUARE

STD - STANDARD

STRUC - STRUCTURAL OR STRUCTURE

SUC - SITE UTILITY CONTRACTOR

TEMP - TEMPERATURE

TOB - TOP OF BEAM

TOD - TOP OF DUCT

TOE - TOP OF EQUIPMENT

TOF - TOP OF FOOTING

TOJ - TOP OF JOIST

TOP - TOP OF PIPE

TOS - TOP OF SLAB OR TOP OF STEEL

TYP - TYPICAL

UNO - UNLESS NOTED OTHERWISE

VEL - VELOCITY

VIB - VALVE IN BOX

VOL - VOLUME

W/ - WITH

W/O - WITHOUT

WIV - WALL INDICATOR VALVE

WS - WATER SERVICE

VALVES AND FITTINGS

T

P

FOB

FOT

CONCENTRIC PIPE REDUCER

ECCENTRIC PIPE REDUCER

GAUGE - PRESSURE

GAUGE - TEMPERATURE OR THERMOMETER

UNION

CLEANOUT

STRAINER

STRAINER - WITH A BLOW DOWN VALVE AND HOSE

CONNECTION

VALVE - DRAIN WITH HOSE END CONNECTION

VALVE - PRESSURE REGULATING

VALVE - SAFETY RELIEF. PIPE DISCHARGE AIR

GAPPED TO FLOOR DRAIN UNLESS NOTED

OTHERWISE.

PLUG - PRESSURE AND TEMPERATURE TEST

TRAP PRIMER

GAUGE - VACUUM WITH STOP

CLEANOUT - TO GRADE OR FINISHED FLOOR

END CAP

MIXING FAUCET

PLUG

HOSE BIB

WALL HYDRANT

VALVE - PLUG

VALVE - SHUTOFF AND BOX

VALVE - SHUTOFF ON RISER

V

VB

TP

CO

VALVE - SOLENOID

S

P/T VALVE - PRESSURE AND TEMPERATURE SAFETY

RELIEF. PIPE DISCHARGE AIR GAPPED TO

FLOOR DRAIN UNLESS NOTED OTHERWISE.

VALVE - CHECK

VALVE - SHUTOFF: BALL, GATE, BUTTERFLY VALVE

(REFER TO SPECIFICATIONS FOR REQUIRED TYPE

BASED ON APPLICATIONS)

AUTOMATIC FLOW CONTROLLER WITH P/T PLUG IN

AND OUT

VALVE - COMBINATION SHUTOFF AND

BALANCING (REFER TO SPECIFICATIONS FOR

REQUIRED TYPE BASED ON APPLICATIONS)

A1

P1 P1OR

A1

OH

P2

B

P2

GENERAL FLOOR PLAN NOTES

RISER OR STACK NUMBER

DETAIL: B = DETAIL DESIGNATION

P2 = SHEET WHERE DETAIL IS LOCATED

FIRE SUPPRESSION HAZARD CLASSIFICATION AND

HAZARD CLASSIFICATION GROUP

SECTION: 1 = SECTION DESIGNATION

P2 = SHEET WHERE DETAIL IS LOCATED

EQUIPMENT REFERENCE. LETTER DESIGNATION

VARIES. REFER TO SCHEDULES.

EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK.

LETTER DESIGNATIONS REFER TO SCHEDULES.

CONNECT TO EXISTING

PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH

IT IS SHOWN UNLESS NOTED OTHERWISE.

DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.

"UP TO" SYMBOL (ITEM ON FLOOR ABOVE)

EXISTING PIPE TO REMAIN

EXISTING PIPE TO BE REMOVED

EXPANSION JOINT

WATER METERM

PIPING SYMBOLS

BOTTOM CONNECTION (45°)

BRANC…