1 - Bill of Material for RFQ-NIAID-2157756.xlsx

XLSX spreadsheet 14 KB Posted

Attached to
Agilent/BioTek Cytation 5 Cell Imaging Multimode Reader
Solicitation number
RFQ-NIAID-2157756
Issued by

View the file

Other files

File Type Posted
4 - FAR 52.212-5 DEC 2022.docx DOCX document
4 - HHSAR 352.docx DOCX document
4 - HHSAR 352.232-71.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Bill of Material for RFQ-NIAID-2157756
This requirement includes an option for trade-in equipment. See below.
Agilent BioTek Cytation 5 Cell Imaging Multi-Mode Reader
https://www.agilent.com/en/product/cell-analysis/cell-imaging-microscopy/cell-imaging-multimode-readers/biotek-cytation-5-cell-imaging-multimode-reader-1623202
#DescriptionCatalogQty
1OBJV 4X WITH HOLDER12205191 each
2CUBE LED 365 ENHANCED ASBY12250071 each
3CUBE IMAGE/FILTER DAPI ASBY12251001 each
4CYT5 WMONO PHASE + WFOV IMAGE configuration: PMT for mono-based system : Low Noise 49984 Software selection : GEN5IPLUS PC:G7 IMAGING CONT ACC W/24-IN MONITOR+ INSTALLCYT5MPW-SN1 each
5AGILENT CYT NORMALIZATION PARTNERSHIPAGCYNP1 each
6Total Shipping & handling11 each
Quote must include FOB destination shipping and Warranty informaiton.
Shipping Destination: Hamilton, Montana 59840
TRADEIN OPTION:
TRADE-IN OFFERS WILL BE TAKEN INTO CONSIDERATION FOR the following equipment:
AGILENT TECHNOLOGIES Spectrometer Mass MODEL G6549ASERIAL# SG2012M001
HEWLETT PACKARD ENTREPRISE Computer CPU model 4QS48UCSERIA# MXL0124LFG
TRAE IN VALUE MUST BE LISTED IN THE QUOTE, IF OFFERING A TRADE.
Vendor will be responible for packaging, shipping, and handling fees to get the trade-in equipment from RML to their facility.
Quotes that offer a trade-in option will be evaluated first. The award decision will be based solely on offers that meet the depreciation value drtermined by NIH Property Management Office of $95,000.00. If the $95,000.00 trade-in valuse/credit is not met, an award may be made without the trade-in option, or procurement may be cancelled entirely.
Quoting Requirements:
Vendor is invited to include past performance references of similar services, including the description of the service, the period of performance, and a client contact name and phone number for that award.
Quote must include response to all minimum service requirements, and all instructions for the quote, for the offer to be accepted as responsive.
Vendor must include Unique Entity ID number from sam.gov registration
Specifications:
Software Compatibility: GEN5IPLUS - Gen5 Microplate Reader and Imager Software included; Gen5 Image+ and Image Prime software available for full image analysis; Gen5 Secure for 21 CFR Part 11 compliance
Type: Cell Imaging Multi-Mode Microplate Reader
Camera: Sony CMOS, 16-bit Gray Scale, Standard or WFOV
Absorbance Range: 230 to 999 nm, 1 nm increments
Dynamic Range:Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades
Contrast Methods: Fluorescence, phase contrast, brightfield, high contrast brightfield, color brightfield and phase contrast
Must include: Wide FOV camera; Fluorescence/brightfield/color brightfield/phase contrast imaging; Monochromator-based UV-Vis absorbance/fluorescence intensity/time resolved fluorescence (secondary)/luminescence
No. of Dispensers: 2 Syringe Pumps
Reading Options: End point, kinetic, spectral scanning and well area scanning
Objectives: 1.25x, 2.5x (2.25x eff), 2.5x (2.75x eff), 4x, 10x, 20x, 40x, 60x
Temperature Range (Metric): 4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C)
Depth: 20.2 in.
Height: 17.5 in.
Width: 16.4 in.
Wattage: 250 W max.
Shaking: Linear, Orbital, Double Orbital
CO2 Concentration Range: 0 to 20%
Accuracy: Monochromator: ±2 nm; Dispenser: ±1 μL or 2%
Dispense Volume: 5 to 1000 μL, 1 μL increments
Plate Type: 6- to 384-well plates; Filters: 6-to 1536 well plates; Imaging: 6-to 1536 well plates; Take3 Plate compatible
Light Source: Xenon Flash; 100 mW 680 nm laser (Alpha Detection)
Identification of the statutory authority permitting other than full and open competition
41 USC 1901(e)(2) and FAR Part 13.106-1(b): Brand Name Only
Due to continuity protocols and compatibility requirements the only known compatible cellular imaging and microplate reader instrument that is compatible with performing assays on our existing Agilent Seahorse XF Pro analyzer and the GEN5IPLUS software is the CELLULAR IMAGING INSTRUMENTATION Mfg. Part No.: CYT5MPW-SN. Compatibility is required as attempts to modify the items currently being used in the development of the next generation vaccine and or therapeutics would result in significant delays and inconsistencies jeopardize the programs mission and goals. This instrument must also be compatible with Gen5 Software.

https://www.agilent.com/en/product/cell-analysis/cell-imaging-microscopy/cell-imaging-multimode-readers/biotek-cytation-5-cell-imaging-multimode-reader-1623202

File details come from the government source that posted it. Updated .