1-3016-LC3_Rev._1.pdf

PDF 57 KB Posted

Attached to
Competitive Selection OH|DOT07526-9
Contract number
DOT07526-9
Issued by
Ohio

About this file

This document is a detailed engineering drawing for a 60' Extra Heavy Tilt Tower, specifically designed for the Ohio DOT (Department of Transportation), prepared by Western Towers located in San Angelo, Texas. The technical schematic is marked as "USE FOR CONSTRUCTION" and provides comprehensive structural specifications for a telecommunications tower with specific design parameters, including base reactions, design load details, and technical components.

The tower is designed with specific technical specifications, including a 60' nominal height, 65' actual height, and engineered to withstand wind speeds of 110 MPH with an ice load of 50 MPH (1" ice). The total estimated shipping weight is 4,750 lbs, with hot-dipped galvanized structural steel meeting ASTM A123 standards. The design includes multiple components such as (2) airMAX NANOBEAM 5AC and PTX-MIC IP STARLIGHT 7100i equipment, with precise measurements and mounting details. The tower is classified with a TIA standard of 222-H, a risk category of 2, and is designed to hold the design load of connecting members at 45% of tower capacity usage.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0"

3'-6 1/2"

5'-5 7/16"

62'-2 5/16"

33'- 3/16"

64'-7 5/16" 2"

SITE NAME: OHIO DOT 1

HEIGHT: 60' NOMINAL

(65' ACTUAL)

TIA STANDARD: 222-H

WIND: 110 MPH

ICE.: 50 MPH (1" ICE)

EXPOSURE CAT.: C

TOPOGRAPHIC

CAT.: 1

RISK CAT.: 2

***USE FOR CONSTRUCTION***

DESIGN NOTES:

POLE STEEL MEETS THE 1.

REQUIREMENTS OF THE TIA

STANDARD LISTED BELOW.

POLE STEEL: A500B2.

FLANGE STEEL: A572-50

PIPE STEEL: A53-B

ALL OTHER STEEL: 36 KSI MINIMUM

ALL STRUCTURAL STEEL IS HOT DIPPED 3.

GALVANIZED PER ASTM A123.

ALL CONNECTIONS ARE DESIGNED 4.

TO HOLD THE DESIGN LOAD OF THE

CONNECTING MEMBERS.

TOWER CAPACITY USAGE = 45%5.

BASE REACTIONS:

AXIAL = 4900 LBS

SHEAR = 2300 LBS

MOMENT = 61000 LB-FT

ADD-ON ITEM

NO.

PART

NUMBER DESCRIPTION QTY

1 3016 60' EXTRA HEAVY TILT 1

2 1239-1 PL 1/2" X 4" X 1'-10 1/8" - 13# CW 1

3 1239-2 PL 3/8" X 4" X 1'-10 1/8" - 10# CW 1

4 5102-3 1/2" FLAT WASHER 3

5 5103-3 1/2" LOCK WASHER 3

6 5041-3 1/2"-13 X 2" FULL THREAD BOLT 3

* 7 4002-1 GROUNDING SYSTEM - (2) CAD WELDED PIGTAILS 1

8 1606-1 LOCK GUARD BENT PLATE 1

* 9 2260 P.O.E. REINFORCEMENT WELDMENT 1

10 2008-2 ANTENNA PIPE WELDMENT W/ MALE NPT THREADS 1

TOTAL ESTIMATED SHIPPING WEIGHT W/GALVANIZING: 4750 LB

DESIGN LOAD TABLE

ELEV. ITEM

64' (2) airMAX NANOBEAM 5AC 64' PTX - MIC IP STARLIGHT 7100i

REVISIONS

REV. DESCRIPTION DATE BY

1 ADDED ITEM NOS. "8", "9", & "10" 3/25/2025 JB

1DEGREE: 10/30/2024SHEET 1 OF 2

TITLE:PROJECTION:

TOLERANCES ARE:

SPG

TOWER - OHIO DOT

3016-LC3

BY:

SPECIFIC 1

WESTERN TOWERS. FOR USE

DATE:

1/8BY WESTERN TOWERS ONLY. FRACTIONAL:

60' EXTRA HEAVY TILT

UNLESS OTHERWISE NOTED,

DIMENSIONS ARE IN INCHES

SCALE: 1:30

SHEET SIZE:

B

DWG. NO.

DECIMAL: (325) 658 - 6539 0.1

PROPRIETARY DRAWINGS

CONFIDENTIAL

INFORMATION WHICH

CANNOT BE ISSUED,

COPIED, OR USED BY

OTHERS WITHOUT WRITTEN

AUTHORIZATION BY

320 W. 26TH - SAN ANGELO, TEXAS 76903

WESTERN TOWERS

REPLACES 2008 FROM 301610

A

B

B

46 5

SCALE 1 : 8

DETAIL A

(3 PLCS)

DRILL AND TAP

FOR 1/2"-13 UNC

2 5/16"

9 9/16"

2 PLCS

3'-6 1/2"

0"

5'-5 7/16"

62'-2 5/16"

33'- 3/16"

64'-7 5/16" 2"

SHEET 2 OF 2

(325) 658 - 6539

3016-LC3

WESTERN TOWERS. FOR USE

SPG

SPECIFIC 1

TOWER - OHIO DOT

BY:SCALE: 1:30

DWG. NO.

B

SHEET SIZE:

UNLESS OTHERWISE NOTED,

DATE:

60' EXTRA HEAVY TILT

TOLERANCES ARE:

BY WESTERN TOWERS ONLY.

PROJECTION: TITLE:

FRACTIONAL:

10/30/2024 1

DIMENSIONS ARE IN INCHES

DEGREE:

0.1DECIMAL:

1/8

PROPRIETARY DRAWINGS

CONFIDENTIAL

INFORMATION WHICH

CANNOT BE ISSUED,

COPIED, OR USED BY

OTHERS WITHOUT WRITTEN

AUTHORIZATION BY

320 W. 26TH - SAN ANGELO, TEXAS 76903

WESTERN TOWERS

SECTION C-C

SCALE 1 : 8

9 REF.

1 1/2"

WELD PIGTAILS ON INSIDE OF BASE TUBE

ITEM NO. "9"

(P.O.E. COVER NOT SHOWN)

1/2"

SCALE 1 : 8

SECTION B-B

96 1/8" X 10 1/8" CUTOUT FOR

1'-11 5/8"

C

C

File details come from the government source that posted it. Updated .