05 - Bldg 1510 Final Drawings - Dated August 09-2021.pdf

PDF 7 MB Posted

Attached to
BLDG 1510 FIRE PROTECTION IMPROVEMENTS Federal contract opportunity
Solicitation number
N4008022B9500
Issued by
Department of the Navy

About this file

This document package includes construction drawings and specifications for fire protection upgrades to Building 1510 at Naval Support Facility Dahlgren in Virginia. The project involves installing a new fire alarm and mass notification system, modifying existing sprinkler systems, demolishing old equipment, and related work. The Navy is soliciting bids under solicitation number N4008022B9500 to complete this work in accordance with the specifications and drawings provided. Key aspects of the project include installing a new addressable fire alarm panel for the building along with devices such as strobes, speakers, duct detectors, and air sampling detectors. The drawings show zoning plans, device locations, and details. Modifications to sprinkler systems on the first and second floors are also specified. Bidders should review all drawings and specifications to understand the full scope of the upgrades and properly price their proposals.

View the file

Other files for this federal contract opportunity

Other files attached to BLDG 1510 FIRE PROTECTION IMPROVEMENTS, newest first.
File Type Posted
B1510 Fire Protection Upgrades Site Pictures Group 1.pdf PDF
B1510 Fire Protection Upgrades Site Pictures Group 3.pdf PDF
B1510 Fire Protection Upgrades - Section 01 31 23.13 20.pdf PDF
B1510 Fire Protection Upgrades - Section 01 58 00.pdf PDF
B1510 Fire Protection Upgrades - Bid Schedule.pdf PDF
B1510 Fire Protection Upgrades - Site Visit Attendance Log.pdf PDF
B1510 Fire Protection Upgrades - Section 01 57 19.01 20.pdf PDF
B1510 Fire Protection Upgrades RFIs and Government Responses.pdf PDF
B1510 Fire Protection Upgrades Site Pictures Group 2.pdf PDF
B1510 Fire Protection Upgrades - Section 01 78 24.00 20.pdf PDF
B1510 Fire Protection Upgrades ADDENDUM 2.pdf PDF
B1510 Fire Protection Upgrades - Amendment 0002.pdf PDF
B1510 Fire Protection Upgrades Shunt Trip Breaker Schedule.pdf PDF
Addendum 1 Bldg 1510 Fire Protection Upgrades.pdf PDF
Amendment 0001 N4008022B9500 BLDG 1510 FIRE PROTECTION.pdf PDF
BLDG 1510 FIRE PROTECTION IMPROVEMENTS SOLICITATION PACKAGE.pdf PDF
06 - Bldg 1510 Specifications - Dated August 09-2021.pdf PDF
BLANK VETTING FORM SECNAV_5512_1_11787 APPROVED AC PASS ID FORM 05282014.pdf PDF
Expected Visitor Form- Blank -- NEW (002).doc DOC document
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B

L

A

N

D

Y

V

D

H

I G

L

E

Y

R

O

A

D

8 4

C

G

A

T

E

424T

C

O

N

I

C

S

H

O

K

T

U

F

C

I

L

I

T

Y

B

E

N

N

I

N

A

D

F O

S T

A

D

"B" GATE

U

V

E

R

N

M

E

N

C

E

TL-5

TL-6

T

B

L

B

M

A

R

P

A

D

P

O

O

L

S

C

H

O

O

L

A

B

C

H

A

P

E

L

D A

H L G

R E

N

R

O A

D

H

A

A

D

SAMPSON CIRCLE

CAFFEE CIRCLE

SAMPSON

R

O

A

D

ADMINISTRATION

C

O

M

O

B

O

Q

W

E

L

A

D

T

H

E

A

T

E

R

B

E

Q

F

I R

E

S

T

A

T

I O

N

T L

TL-2

TL-1

T L -4

T L -8

POST OFFICE

TL-7

V

A

U

M

I

CASKEY ROAD

P

I E

R

R

E

C

R

E

A

T

I O

N

G

I

L

M

O

R

E

ROAD

SECURITY OFFICE

R

O

A

D

T

I S

D

A

L

E

TOWER

MAIN RANGE

M

HOUSING

PUBLIC WORKS DEPT (W)

R E

C E

IV

IN

G

404T

COMPT

T

CASEY

ROAD

D

A

H

L

G

R

A

D

B

C

Q

T

M

C

V

A

Y

R

O

A

D

120B

POTOMAC RIVER

E

D

E

R

I C

K

S

B

U

R

G

C

H

M

O

N

D

B R

O N

S O

N R

O A

D

U

S

G

O

V

E

R

N

M

E

N

C

E

PROJECT LOCATION

MAIN GATE

FI

LE

N

AM

E:

OU

RE

F:

PL

OT

D

AT

E:

8/1

4/2

9 1 0:5

0:1 8 A

M

1.1

G-

1.D W

G

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

DA

HL

GR

EN

, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

W

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T

S

O U

P

T

O M

A C

N A

V A

L

S

U P

P O

C

I L I T

Y

D

A H

L G

R E

N

V

A

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

KU WP KU

4 5

C O

V E

R

S

H E

E T

G-001

SHEET

NUMBER SHEET TITLE NAVFAC

DWG NO.

G-001 COVER SHEET 13112628

A-001 ARCHITECTURAL SYMBOLS - DETAILS 13112629

AD-101 REFLECTED CEILING PLAN - FIRST FLOOR 13112630

AD-102 REFLECTED CEILING PLAN - SECOND FLOOR 13112631

FA-001 FIRE ALARM NOTES & LEGEND 13112632

FA-002 FIRE ALARM ABOVE FLOOR ZONING PLAN 13112633

FA-003 FIRE ALARM ABOVE FLOOR ZONING PLAN 13112634

FA-004 FIRE ALARM UNDER FLOOR ZONING PLAN 13112635

FA-101 FIRE ALARM 1ST FL. DEMOLITION PLAN - AREA-A 13112636

FA-102 FIRE ALARM 1ST FL. DEMOLITION PLAN - AREA-B & C 13112637

FA-103 FIRE ALARM 1ST FL. UNDER FL. DEMO PLAN - AREA-A 13112638

FA-104 FIRE ALARM 1ST FL. UNDER FL. DEMO PLAN - AREA -

B&C 13112639

FA-105 FIRE ALARM 2ND FL. DEMOLITION PLAN - AREA-A 13112640

FA-106 FIRE ALARM 2ND FL. DEMOLITION PLAN - AREA-B & C 13112641

FA-107 FIRE ALARM 2ND FL. UNDER FL. DEMO PLAN -

AREA-A 13112642

FA-108 FIRE ALARM 2ND FL. UNDER FL. DEMO PLAN - AREA -

B&C 13112643

FA-121 FIRE ALARM 1ST FL. NEW WORK PLAN - AREA-A 13112644

FA-122 FIRE ALARM 1ST FL. NEW WORK PLAN - AREA-B & C 13112645

FA-123 FIRE ALARM 1ST FL. UNDER FL. NEW PLAN - AREA-A 13112646

FA-124 FIRE ALARM 1ST FL. UNDER FL. NEW PLAN - AREA - B

& C 13112647

FA-125 FIRE ALARM 2ND FL. NEW WORK PLAN - AREA-A 13112648

FA-126 FIRE ALARM 2ND FL. NEW WORK PLAN - AREA-B & C 13112649

FA-127 FIRE ALARM 2ND FL. UNDER FL. NEW PLAN - AREA-A 13112650

FA-128 FIRE ALARM 2ND FL. UNDER FL. NEW PLAN - AREA-B

& C 13112651

FA-129 FIRE ALARM 3RD FL. NEW WORK PLAN - AREA-A 13112652

FA-201 FIRE ALARM ENLARGED PLANS 13112653

FA-501 FIRE ALARM DETAILS 13112654

SHEET

NUMBER SHEET TITLE NAVFAC

DWG NO.

FA-502 FIRE ALARM DETAILS 13112655

FA-503 FIRE ALARM DETAILS 13112656

FA-504 FIRE ALARM GRAPHIC ANNUNCIATOR 13112657

FA-601 FIRE ALARM SCHEDULES 13112658

FA-602 FIRE ALARM RISER DIAGRAM 13112659

FX-001 FIRE SUPPRESSION NOTES & LEGEND 13112660

FX-002 FIRE SUPPRESSION ZONING PLAN 13112661

FX-101 FIRE SUPPRESSION 1ST FL. DEMO PLAN - AREA-A 13112662

FX-102 FIRE SUPPRESSION 1ST FL. DEMO PLAN - AREA-B&C 13112663

FX-105 FIRE SUPPRESSION 2ND FL. DEMO PLAN - AREA-A 13112664

FX-106 FIRE SUPPRESSION 2ND FL. DEMO PLAN - AREA-B&C 13112665

FX-121 FIRE SUPPRESSION 1ST FL. NEW WORK PLAN -

AREA-A 13112666

FX-122 FIRE SUPPRESSION 1ST FL. NEW WORK PLAN -

AREA-B & C 13112667

FX-125 FIRE SUPPRESSION 2ND FL. NEW WORK PLAN -

AREA-A 13112668

FX-126 FIRE SUPPRESSION 2ND FL. NEW WORK PLAN -

AREA-B & C 13112669

FX-201 FIRE SUPPRESSION DETAILS & SECTIONS 13112670

FX-202 FIRE SUPPRESSION DETAILS & SECTIONS 13112671

FX-203 FIRE SUPPRESSION DETAILS & SECTIONS 13112672

FX-204 FIRE SUPPRESSION DETAILS & SECTIONS 13112673

FX-501 FIRE SUPPRESSION DETAILS 13112674

FX-502 FIRE SUPPRESSION DETAILS 13112675

FX-601 FIRE SUPPRESSION RISER DIAGRAM 13112676

E-001 SYMBOLS - ABBREVIATIONS 13112677

E-101 ELECTRICAL PANEL LAYOUT - FIRST FLOOR 13112678

E-102 ELECTRICAL PANEL LAYOUT - SECOND FLOOR 13112679

CONSTRUCTION CONTRACT NO.

FIRE PROTECTION UPGRADES IN BUILDING 1510

DAHLGREN, VIRGINIA

WORK ORDER NO.

LOCATION MAP DRAWING INDEX NOTICES

NAVAL SUPPORT FACILITY DAHLGREN DIVISION, SOUTH POTOMAC

1558920

N

VICINITY MAP

N 1 52 13112628

AutoCAD SHX Text

DAHLGREN

AutoCAD SHX Text

NAVSWC

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

RICHMOND

AutoCAD SHX Text

AutoCAD SHX Text

RAPPAHANNOCK RIVER

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

RIVER

AutoCAD SHX Text

POTOMAC

AutoCAD SHX Text

FREDERICKSBURG

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ALEXANDRIA

AutoCAD SHX Text

ARLINGTON

AutoCAD SHX Text

WASHINGTON D.C.

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/1

4/2

9 1 0:5

0:2 1 A

M

1.1

A-

1.D W

G

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

DA

HL

GR

EN

, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T

S

O U

T

O M

A C

N A

V A

L

S

U P

P O

C

I L I T

Y

D

A H

L G

R E

N

V

A

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

KU WP KU

4 5

A R

C H

I T

E C

T U

R A

L

S

Y M

B O

E T

A I L

S

A-001

5"x7" BRUSHED ALUMINUM

WITH FINISHED EDGES

AND FRONT CORNERS EASED

COUNTER SUNK FLAT

HEAD MACHINE SCREW

DETAIL

NOT TO SCALE

STAINLESS STEEL COVER PLATE

SURFACE MOUNTED DEVICE

DEMOLITION

NOT TO SCALE

DETAIL

ACT. OR PLASTER

CEILING

REMOVE EXPOSED CONDUIT WITH

WIRING

REMOVE WALL MOUNTED

JUNCTION BOX

REMOVE SURFACE MOUNTED

DEVICE

EXISTING PLASTER OR GYPSUM

TO REMAIN. CLEAN AFFECTED

AREA COMPLETELY. PATCH AND

REPAIR HOLES RESULTING FROM

REMOVAL OF DEVICES. PAINT

PARTITION TO MATCH SURFACES

FROM BREAK TO BREAK.FLEXIBLE METAL CONDUIT

FISHED IN EXISTING WALL

CUT EXISTING GYPSUM BOARD

FLUSH WITH SURFACE

WALL AND MOUNT DEVICE BOX

PROVIDE SURFACE MOUNTED

PATCH AROUND CABLE

EXISTING GYPSUM BOARD WALL

JUNCTION BOX ABOVE CEILING

CUT HOLE IN EXISTING WALL AND

EXISTING CEILING TILE

CONDUIT TO NEXT DEVICE

FIRE ALARM DEVICE RECESSED

IN EXISTING GYPSUM WALL

NOT TO SCALE

DETAIL

NOTIFICATION DEVICE ON

EXISTING CONCRETE OR

NOT TO SCALE

DETAIL

CEILING SLAB

SURFACE MOUNT FIRE ALARM DEVICE AS

EXISTING MASONARY OR CONCRETE WALL

NOTED ON FIRE ALARM PANS

WITH TWO ANCHORS

MOUNT JUNCTION BOX TO WALL

3/4" CONDUIT TO FIRE ALARM SYSTEM

INDICATING DEVICE

TO NEXT FIRE ALARM

SYSTEM DEVICE

CONDUIT STRAP

SURFACE MOUNT PULL STATION

AS INDICATED ON FIRE ALARM DETAILS

MASONARY WALL

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. DETAILS ARE TYPICAL AND APPLY TO ALL DEVICE DEMOLITION AND

INSTALLATION FOR FA SERIES DRAWINGS.

PROVIDE BLANK COVER PLATE AS INDICATED ON RECESSED DEVICES

BOXES ABANDONED AS A RESULT OF FIRE ALARM DEMOLITION.

SYMBOLS

MD CEILING MOUNTED MOTION DETECTOR.

2' x 2' LIGHT FIXTURE

2' x 4' LIGHT FIXTURE

CEILING MOUNTED PUBLIC ANNOUNCEMENT SPEAKER.P

NOTIFICATION DEVICE ON

EXISTING CONCRETE OR

NOT TO SCALE

DETAIL

CEILING SLAB

SURFACE MOUNT FIRE ALARM DEVICE AS

EXISTING CMU WALL

NOTED ON FIRE ALARM PANS

WITH TWO ANCHORS

MOUNT JUNCTION BOX TO WALL

3/4" CONDUIT TO FIRE ALARM SYSTEM

INDICATING DEVICE

TO NEXT FIRE ALARM

SYSTEM DEVICE

CONDUIT STRAP

SURFACE MOUNT PULL STATION

AS INDICATED ON FIRE ALARM DETAILS

MASONARY WALL WITH CEILING

NOTCHED CEILING TILE FOR THE CONDUIT

TO BE ROUTED ABOVE THE CEILING.

2 52 13112629

HI

GH

D

EN

SI

TY

SH

EL

VI

NG HI

GH

D

EN

SI

TY

SH

EL

VI

NG

HIGH DENSITY

HIGH DENSITY

MAIN SW

GR

ELEC

115B

MECH

115A

MECH

LAB

MECH

LAB

LAB

LAB

VAULT

114A

NMCI

JAN

OFFICE

135A

OFFICE

OFFICE

LIBRARY

CORR.

OFFICE

OFFICE CORR.

132D

LAB

132A

LAB

BREAK

MEN

WOMEN

140A

MECH

MECH

LAB 155

LAB

LAB

108A

LAB

LAB

STORAGE

STORAGE

SECURITY

102A

SECURITY

V101 101

LOBBY

OFFICE CORR.

MECH

E101 S101

H101

H102 H103

LAB136A

LAB

H104 H105

S103 160A

MECH

S104

E102

173A

ELEC

170A

MECH

V102

LIBRARY

LOBBY

OFFICE

STORAGE

174A

STORAGE

LAB

LAB

LAB

LAB

130A

LAB

S102

H104

EQUIP

EQUIP

P

PP

P

P

P

P

P

P

P

PP

PP

P

P

P

P

P

P

P

P

P

PPP

P P P

P

P P P

P P P

P P P

P P P

P

P

P P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P P

P P

P

P

PP

P P

P

PP

P P

P

P

P

P

P

P

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/1

4/2

9 1 0:5

0:2 4 A

M

1.1

AD

-1

.D

W G

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

DA

HL

GR

EN

, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T

S

O U

T

O M

A C

N A

V A

L

S

U P

P O

C

I L I T

Y

D

A H

L G

R E

N

V

A

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

KU WP KU

4 5

R E

F L

E C

T E

D

C

E I L

I N

G

P

L A

N

F

I R

O

O R

AD-101

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT

AND COORDINATE ALL WORK PRIOR TO THE START OF

CONSTRUCTION.

GENERAL NOTES

NOTES

1. TEMPORARILY SUPPORT ALL CEILING MOUNTED DEVICES FROM

THE STRUCTURE ABOVE INCLUDING BUT NOT LIMITED TO: LIGHT

FIXTURES, FIRE ALARM STROBES/HORNS, DIFFUSERS, GRILLES,

SPEAKERS, AND FIRE ALARM DEVICES. REMOVE AND STORE

CEILING TILE TO FACILITATE SPRINKLER WORK. UPON

COMPLETION OF WORK INSTALL CEILING TILE RETAINED. BASE

BID ON REPLACEMENT OF 10% OF TILES DUE TO BREAKAGE AND

DAMAGE.

2. DEMOLISH EXISTING CEILING. TURN OVER CEILING TILES TO

FACILITY MANAGER FOR ATTIC STOCK. PROVIDE CEILING TO

MATCH EXISTING 4" HIGHER THAN PREVIOUS CEILING LEVEL TO

ALLOW FOR PROPER SPRINKLER INSTALLATION.

REFLECTED CEILING PLAN - FIRST FLOOR

SCALE: 3/32'' = 1' - 0''

GRAPHIC SCALE

CAUTION: IF THIS DRAWING IS A REDUCTION,

8' 4' 0 24'8' 16'

3/32"=1'-0"

GRAPHIC SCALES MUST BE USED.

N

LEGEND

LIMITS OF CEILING TO BE REPLACED.

NOTES CONTINUED

3. DEMOLISH EXISTING CEILING. CAREFULLY REMOVE EXISTING

TILES AND TURN OVER TO FACILITY MANAGER FOR ATTIC STOCK.

PROVIDE CEILING TO MATCH EXISTING AND LOCATE AT 9'-6" AFF

TO ALLOW FOR SPRINKLER INSTALLATION.

4. PROVIDE GYPSUM SOFFIT IN AREA INDICATED TO ALLOW FOR

ACOUSTICAL CEILING TO BE RAISED WHILE MAINTAINING

EXISTING CEILING HEIGHT BELOW MECHANICAL UNIT IN THIS

AREA.

5. RELOCATE EXISTING LIGHT FIXTURE TO POSITION INDICATED.

6. PROVIDE FIRE STOP IN ALL PENETRATIONS, RATED TO ONE

HOUR.

3 52 13112630

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

UP

STORAGE

10 SF

DESKS

DESK

EQUIPMENT

DESK

BREAK

LAB

LAB

LAB

LAB 214

CONFERENCE

RESTROOM

RESTROOM

JANITOR

E201

COPY

ROOM

CONFERENCE

H201

S201

H202

STORAGE

ROOF AREA

LOW ROOF

LOW ROOFS202

236A

LAB

LAB

HALLWAY

241B

OFFICE

241A

OFFICE

233A

OFFICE 233

OFFICE

MECH

S203 240A

OFFICE

242A

OFFICE

CORR.

OFFICE

CORR.

HALLWAY

244A

OFFICE

OFFICE

CORR.

246B

OFFICE246C

OFFICE

246D

OFFICE

H207

OFFICE

246A

OFFICE

250C

OFFICE

250B

OFFICE

250A

OFFICE250

OFFICE

OFFICE

OFFICE

STORAGE

E202

S204

OFFICE

CORR.

H205

OFFICE

CORR.

KITCHEN

CONFERENCE

OFFICE CORR.

267A

OFFICE

CORR.

CLOSET

MEN

WOMEN

JAN.

0B

OF

FI

CE

H204

4A

ST

OR

AG

E

2A

ST

OR

AG

E

METAL

STAIRS

WITH

HANDRAILS

T-1

MDP-1

STORAGE

EQUIP

SERVERS

SERVERS

SERVERS

SERVERS

SERVERS

SERVERS

SERVERS

EQ

UI

P

EQ

UI

PEQ

UI

P

EQ

UI

P

EQ

UI

P

EQ

UI

P

EQUIP

DESKS

DESKS

DESKS

SERVERS

SERVERS

DESKS

DESKS

DESKS

SERV

SERVERS

DESKS

DESKS

TV W

ALL

DESKS

DESKS DESKS

DESK

TV'S

EQU

EQU

PP

PP

P

P

P

P

P P

P

P

P

PP

P

P P

P

P

P

P

P

PPP

P

PP

P

PP

P P

P P

PP

P P

P

P

P

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/1

4/2

9 1 0:5

0:2 6 A

M

1.1

AD

-1

.D

W G

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER:ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

DA

HL

GR

EN

, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T

S

O U

T

O M

A C

N A

V A

L

S

U P

P O

C

I L I T

Y

D

A H

L G

R E

N

V

A

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

KU WP KU

4 5

R E

F L

E C

T E

D

C

E I L

I N

G

P

L A

N

S

E C

O N

D

F

L O

O R

AD-102

REFLECTED CEILING PLAN - SECOND FLOOR

SCALE: 3/32'' = 1' - 0''

GRAPHIC SCALE

CAUTION: IF THIS DRAWING IS A REDUCTION,

8' 4' 0 24'8' 16'

3/32"=1'-0"

GRAPHIC SCALES MUST BE USED.

N

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT

AND COORDINATE ALL WORK PRIOR TO THE START OF

CONSTRUCTION.

GENERAL NOTES

NOTES

1. TEMPORARILY SUPPORT ALL CEILING MOUNTED DEVICES FROM

THE STRUCTURE ABOVE INCLUDING BUT NOT LIMITED TO: LIGHT

FIXTURES, FIRE ALARM STROBES/HORNS, DIFFUSERS, GRILLES,

SPEAKERS, AND FIRE ALARM DEVICES. REMOVE AND STORE

CEILING TILE TO FACILITATE SPRINKLER WORK. UPON

COMPLETION OF WORK INSTALL CEILING TILE RETAINED. BASE

BID ON REPLACEMENT OF 10% OF TILES DUE TO BREAKAGE AND

DAMAGE.

2. PROVIDE FIRE STOP IN ALL PENETRATIONS, RATED TO ONE

HOUR.

4 52 13112631

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

DOWN

DOWN

XXX #'-#"

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/8

/20

9:

:17 A

M

1.5

4_

FA

-0

.D

W G

MCP ACJ MTS

F I R

E

A

L A

T

G

E N

D

13112632

FA-001

1. THE SCOPE OF WORK FOR THIS BUILDING INCLUDES PROVIDING A COMPLETE, BUILDING VOICE FIRE ALARM AND DETECTION SYSTEM AND MASS NOTIFICATION SYSTEM FOR NAVAL SUPPORT FACILITY (NSF) DAHLGREN, BUILDING 1510.

THE SYSTEM MUST INCLUDE ALL WIRING, RACEWAYS, PULL BOXES, TERMINAL CABINETS, OUTLET AND MOUNTING BOXES, CONTROL EQUIPMENT, ALARM AND SUPERVISORY SIGNALS, INITIATING DEVICES, ALARM NOTIFICATION APPLIANCES, NOTIFICATION APPLIANCE BOOSTER PANELS, AMPLIFIERS, INTERFACE EQUIPMENT, AND ALL OTHER ACCESSORIES AND MISCELLANEOUS ITEMS INCLUDING SOFTWARE, SYSTEM PROGRAMMING, TESTING AND CONSTRUCTION PERMITS REQUIRED FOR A COMPLETE OPERATING SYSTEM EVEN THOUGH EACH ITEM IS NOT SPECIFICALLY MENTIONED OR DESCRIBED. PROVIDE SYSTEM COMPLETE AND READY FOR OPERATION. PROVIDE A KING FISHER RADIO TRANSMITTER, INCLUDING ANTENNAE, TRANSIENT VOLTAGE SURGE SUPPRESSOR, CONDUIT, WIRING, AND PROGRAMMING REQUIRED TO PROVIDE A REPORTING SYSTEM COMPLETE AND READY FOR OPERATION. PROVIDE A FEDERAL SIGNAL MASS NOTIFICATION TRANSMITTER FOR BUILDING 1510 TO PROVIDE VOICE MESSAGES FROM THE EXISTING GIANT VOICE SYSTEM. THE SYSTEM MUST COMPLY WITH UFC 1-200-01 (9/1/2013, CHANGE 1), UFC 3-600-01 (11/28/2016), UFC 3-600-10N (8/2007) & UFC 4-021-01 (1/2010), NFPA STANDARDS 70 (2017), 72 (2016), AND 75 (2017). IN ADDITION, THE EQUIPMENT PROVIDED MUST BE FROM A SINGLE MANUFACTURER AND MUST BE LISTED FOR THE INTENDED PURPOSE BY A NATIONAL RECOGNIZED TESTING

LABORATORY.

2. REMOVE THE EXISTING FIRE ALARM AND HALON SYSTEMS IN BUILDING 1510 INCLUDING ALL FIRE ALARM EQUIPMENT AND APPLIANCES. IN ADDITION, REMOVE EXISTING FIRE ALARM CABLES, INCLUDING CONDUIT. PATCH AND PAINT DISTURBED AREAS TO MATCH EXISTING CONDITIONS. SALVAGE THE KING FISHER PANELS AND RETURN TO THE GOVERNMENT.

SALVAGE ALL FIRE ALARM PANELS, EQUIPMENT, INITIATING DEVICES AND NOTIFICATION DEVICES AND DELIVER TO THE

BASE FIRE ALARM SHOP IN BUILDING 480.

3. MAINTAIN EXISTING FIRE ALARM SYSTEMS FULLY OPERATIONAL UNTIL THE NEW FIRE ALARM SYSTEM HAS BEEN INSTALLED, TESTED AND ACCEPTED BY THE NAVFAC FIRE PROTECTION ENGINEER. AS NEW FIRE ALARM EQUIPMENT AND APPLIANCES ARE INSTALLED, THEY SHALL BE LABELED "NOT IN SERVICE" UNTIL THE NEW FIRE ALARM SYSTEM IS ACCEPTED. AFTER THE NEW SYSTEM IS ACCEPTED REMOVE LABELS FROM NEW FIRE ALARM EQUIPMENT AND APPLIANCES, AND LABEL EXISTING

FIRE-ALARM EQUIPMENT "NOT IN SERVICE" UNTIL REMOVED.

4. ALL WIRING MUST BE FROM APPLIANCE TERMINAL TO APPLIANCE TERMINAL. CONDUCTORS THAT ARE TERMINATED, SPLICED, OR OTHERWISE INTERRUPTED IN ANY ENCLOSURE, CABINET, MOUNTING, OR JUNCTION BOX MUST BE CONNECTED TO SCREW-TYPE TERMINAL BLOCKS. WIRE NUTS AND SIMILAR DEVICES ARE PROHIBITED.

5. ALL FIRE ALARM CIRCUITS MUST BE SUPERVISED AS FOLLOWS IN ACCORDANCE WITH NFPA 72:

INITIATING DEVICE CIRCUITS (IDC) - CLASS B

NOTIFICATION APPLIANCE CIRCUITS (NAC) - CLASS B (SEE CONTRACT FOR BID OPTION FOR NAC TO BE CLASS A), SYNCHRONIZED

SIGNALING LINE CIRCUITS (SLC) - CLASS A

6. PROVIDE VISUAL WARNING STROBE/AUDIBLE NOTIFICATION APPLIANCES TO ACHIEVE MAXIMUM AUDIBILITY, INTELLIGIBILITY AND VISIBILITY IN ACCORDANCE WITH NFPA 72 GUIDELINES AND REQUIREMENTS OF UFC 04-021-01. PROVIDE CARE IN LOCATING VISUAL WARNING STROBE APPLIANCES TO ENSURE VISIBILITY AND AVOID OBSTRUCTIONS. PROVIDE GENERAL

EVACUATION FOR BUILDING 1510.

7. PROVIDE STROBE NOTIFICATION APPLIANCE CIRCUIT POWER REQUIREMENTS AND CONDUCTOR SIZES AS NOT TO EXCEED A 15% (3.6v) VOLTAGE DROP. EACH VISUAL NOTIFICATION APPLIANCE CIRCUIT MUST NOT EXCEED 75% OF ITS RATED OUTPUT WHICH ASSUMES THE MAXIMUM AVAILABLE LOAD IS DISTRIBUTED EQUALLY OVER 4 CIRCUITS. PROVIDE 70.7 VRMS AUDIO VOICE NAC CIRCUITS AND CONDUCTOR SIZES TO NOT ALLOW MORE THAN 0.5 dB (12.5%) LOSS.

8. UNLESS NOTED OTHERWISE PROVIDE INTERIOR SPEAKER APPLIANCES AT ¼-WATT TAP AND EXTERIOR SPEAKERS AT 2-WATT TAP. IN ADDITION, INDIVIDUAL SPEAKER AMPLIFIER/CIRCUIT MUST NOT BE LOADED MORE THAN 70% OF RATED

AMPLIFIER POWER OUTPUT.

9. COORDINATE LOCATION OF LED TEXT SIGN WITH THAT OF EXISTING BUILDING FEATURES SUCH AS EXIT SIGNS, CONDUIT

AND PIPE.

10. LABEL ALL ADDRESSABLE INPUT/OUTPUT FIRE ALARM COVER PLATES AND APPLIANCES (INCLUDING SPEAKERS, STROBES, SMOKE SENSORS, MANUAL PULL STATIONS AND ADDRESSABLE MODULES) WITH THEIR ADDRESS UTILIZING A LABELING MACHINE. DO NOT USE HAND WRITTEN LABELS. PROVIDE NAC OR SLC NUMBER FOLLOWED BY APPLIANCE NUMBER. MATCH

EACH SLC FIELD APPLIANCE ADDRESS WITH THE FIRE ALARM DISPLAY ADDRESS.

11. PROVIDE ALL FIRE ALARM APPLIANCES IN LAT OR SUSPENDED CEILINGS CENTER OF TILE. PROVIDE STEEL TILE BRIDGE TO SUPPORT DEVICE. COORDINATE FIRE ALARM APPLIANCE LOCATIONS WITH CEILING GRID, LIGHTS AND DIFFUSERS.

12. UNO, PROVIDE ELECTRICAL METALLIC TUBING (EMT) THROUGHOUT THE PROJECT. REFERENCE TO CONDUIT IS EQUIVALENT TO STATING EMT. PROVIDE ALL WIRING IN CONDUIT. FLEXIBLE METAL CONDUIT IS LIMITED TO 6 FEET AND MUST BE

SECURED PER THE NATIONAL ELECTRIC CODE.

13. PROVIDE CONDUIT AS UNOBTRUSIVELY AS POSSIBLE, AS CLOSE AS POSSIBLE TO FLOOR/ CEILING SLAB AND PARALLEL AND AT RIGHT ANGLES TO STRUCTURAL STEEL OR CONCRETE ELEMENTS. THESE DRAWINGS ARE DIAGRAMMATIC TO SHOW

DESIGN INTENT ONLY.

14. PROVIDE ELECTRICAL BOXES AS FOLLOWS: U.N.O. PROVIDE CAST METAL BELL TYPE BOXES WITH THREADED HUBS ON EXPOSED WORK, EXCEPT WHERE FACTORY BOXES ARE PROVIDED. CONCEALED BOXES MAY BE STAMPED STEEL BOXES.

PROVIDE TERMINAL CABINETS OF SOLID WALL CONSTRUCTION WITH NO FACTORY CONDUIT KNOCK OUTS.

15. CORE DRILL WITH A CORE BIT ANY PENETRATIONS IN MASONRY WALLS AND FLOOR/CEILING SLABS.

16. AFTER CONDUIT INSTALLATION, CLEAN AND PROTECT PENETRATIONS IN FIRE RESISTIVE WALLS AND FLOOR/CEILING AND ROOF SLABS WITH A COMPLETE, TESTED THROUGH-PENETRATION ASSEMBLY SYSTEM OF EQUAL OR GREATER FIRE RESISTANCE TO THE ASSEMBLY BEING PENETRATED. LABEL EACH SYSTEM TO IDENTIFY FIRESTOP UL SYSTEM NUMBER, FIRESTOP RATING, DATE OF INSTALLATION AND CONTRACTOR'S NAME. RESTORE ALL PENETRATIONS THROUGH SLAB OR

CUTTING OF FIRE RATED ASSEMBLIES TO THEIR ORIGINAL FIRE RATING.

17. SECURE ALL NECESSARY CONSTRUCTION PERMITS, INSPECTIONS AND FINAL SYSTEM ACCEPTANCE.

18. CONTRACT DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY AND MUST BE USED IN CONJUNCTION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. COORDINATE ALL DRAWINGS AND SPECIFICATIONS PRIOR TO COMMENCING WORK. QUESTIONS REGARDING DESIGN INTENT OR SYSTEM OPERATION MUST BE PROMPTLY BROUGHT TO THE

CONTRACTING OFFICER.

19. AVOID ALL CONFLICTS WITH LIGHT FIXTURES, HVAC DIFFUSERS, GRILLS, DUCTS, CONDUIT AND OTHER PIPING OR OTHER OBSTRUCTIONS ENCOUNTERED. COORDINATE ALL WORK WITH FIELD CONDITIONS. CONTRACTOR MUST PROMPTLY NOTIFY CONTRACTING OFFICER PRIOR TO INITIATING WORK IF ANY MOUNTING LOCATIONS ARE OBSTRUCTED AND/OR IF ANY

MOUNTING CONFLICTS OR PROBLEMS ARE DISCOVERED.

20. BOTH EXPOSED AND CONCEALED CONDUIT INCLUDING RISERS UP TO 2 INCHES IN DIAMETER MUST UTILIZE COMPRESSION

TYPE STEEL FITTINGS AND CONNECTORS. UNLESS NOTED OTHERWISE PROVIDE ALL CONDUIT 3

4-INCH MINIMUM TRADE

SIZE. PROVIDE VERTICAL RISERS ONE INCH DIAMETER MINIMUM. PROVIDE PLENUM RATED WIRING CONDUCTORS (TYPE FPLP) WHEN FLEX CONDUIT IS UTILIZED. UNLESS SPECIFIED DIFFERENTLY BY FIRE ALARM EQUIPMENT MANUFACTURER PROVIDE SOLID COPPER WIRING CONDUCTORS INSTALLED IN CONDUIT FOR THE FOLLOWING CIRCUITS (AT MINIMUM):

INITIATION - 14/2 AWG

SIGNALING LINE CIRCUIT - 18/2 AWG TWISTED SHIELDED PAIR

VISUAL NOTIFICATION APPLIANCES (STROBES) - 14/2 AWG

VISUAL NOTIFICATION APPLIANCES (FOR TEXT SIGNAGE) - 14/2 AWG

AUDIO NOTIFICATION APPLIANCES - 16/2 AWG TWISTED SHIELDED PAIR

120 VAC - PRIMARY POWER - NO. 12 AWG, THHN/THWN 600VAC INSULATED

ALL WIRING MUST BE UL LISTED FOR ITS INTENDED USE.

21. VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE BEFORE PROCEEDING WITH WORK TO VERIFY THE LOCATION OF ALL SYSTEM COMPONENTS. REPORT ANY DISCREPANCIES WITH THESE DRAWINGS TO THE CONTRACTING OFFICER

IMMEDIATELY.

22. DO NOT CUT, DRILL OR BURN ANY STRUCTURAL MEMBERS UNLESS PREVIOUSLY APPROVED BY THE CONTRACTING

OFFICER.

23. COORDINATE ALL WORK WITH THE CONTRACTING OFFICER, INCLUDING ACCESS TO THE BUILDING. SCHEDULE WORK TO MINIMIZE DISRUPTION TO OCCUPANTS OF THE BUILDING. BEFORE THE EXISTING FIRE ALARM SYSTEM IS SHUTDOWN, NOTIFY THE CONTRACTING OFFICER 14 DAYS IN ADVANCE.

24. MAINTAIN CLEAR EGRESS PATHS IN BUILDING DURING CONSTRUCTION IF AREA IS TO REMAIN OCCUPIED. WHEN OCCUPIED, WORK AREAS MUST BE ROPED OFF. CONSTRUCTION WORK WHICH BLOCKS OR OTHERWISE IMPEDES AN EGRESS PATH

MUST ONLY BE PERFORMED DURING HOURS WHEN THE BUILDING IS UNOCCUPIED.

25. PREPARE A DETAILED WRITTEN PHASING PLAN AND SUBMIT FOR APPROVAL TO THE CONTRACTING OFFICER. NO WORK SHALL START UNTIL THIS PLAN IS APPROVED. REPORT CHANGES TO THE CONTRACTING OFFICER ON A WEEKLY BASIS.

26. "PROVIDE" MEANS CONTRACTOR MUST FURNISH NEW AND INSTALL COMPLETE AND READY FOR INTENDED USE.

27. "REMOVE" MEANS CONTRACTOR MUST DISCONNECT, REMOVE FROM SITE AND LEGALLY DISPOSE.

28. DAHLGREN FIRE ALARM AND SPRINKLER OUTAGE PROCEDURES

ALL REQUIRED OUTAGES OF THE SPRINKLER AND FIRE ALARM SYSTEM SHALL BE COORDINATED THROUGH THE

CONTRACTING OFFICER NOT LESS THAN 15 WORKING DAYS IN ADVANCE.

A FIRE WATCH, AT CONTRACTOR'S COST, WILL BE CONDUCTED CONTINUOUSLY THROUGHOUT THE DURATION OF THE OUTAGE IN ALL AREAS AFFECTED BY THE OUTAGE. FINDINGS/COMMENTS WILL BE DOCUMENTED HOURLY ON FIRE WATCH FORMS PROVIDED BY THE DAHLGREN FIRE PREVENTION DIVISION. DOCUMENTATION OF FINDINGS WILL BE MADE AVAILABLE TO THE DAHLGREN FIRE DEPARTMENT OFFICIALS UPON THEIR REQUEST. IN ACCORDANCE WITH PROCEDURES

OUTLINED IN OPNAVINST 11320.23G.

OUTAGE TIME DURATIONS WILL NOT BE PERMITTED TO SPAN THE ENTIRE DURATION OF THE PROJECT. OVERNIGHT OUTAGES WILL NOT BE PERMITTED UNLESS WORK IS BEING DONE DURING THAT TIME PERIOD AND THE SPRINKLER/FIRE ALARM SYSTEM IS PUT BACK INTO SERVICE WITHIN AN HOUR FROM COMPLETION OF WORK. OUTAGE SHALL BE LIMITED TO

8 HOURS INCLUDING TIME FOR DRAINING AND REFILLING.

BOTH THE SPRINKLER AND FIRE ALARM SYSTEMS ARE NOT PERMITTED TO HAVE AN OUTAGE FOR MORE THAN AN HOUR BEFORE STARTING WORK. THE FIRE ALARM AND SPRINKLER SYSTEM SHALL BE RESTORED WITHIN AN HOUR OF COMPLETION OF WORK. THE CONTRACTOR CANNOT LEAVE THE CONSTRUCTION SITE UNPROTECTED. THE SPRINKLER

SYSTEM SHALL BE FILLED WITHIN AN HOUR OF COMPLETION OF WORK.

29. FIRE ALARM

CONTRACTOR MUST OBTAIN THE SERVICES OF THE NAVFAC DAHLGREN FIRE ALARM TECHNICIAN RESPONSIBLE FOR MAINTAINING DAHLGREN FIRE ALARM SYSTEMS, TO PERFORM OUTAGES OF THE EXISTING FIRE ALARM SYSTEMS. ALL FIRE ALARM SYSTEMS ARE MAINTAINED BY NAVFAC DAHLGREN FIRE ALARM TECHNICIANS AND ONLY THESE CONTRACTORS CAN PERFORM THE SHUTDOWN AND RESTARTING OF SAID SYSTEMS. CONSTRUCTION GENERAL CONTRACTOR MUST REQUEST THAT A TICKET BE SUBMITTED FOR THE NAVFAC DAHLGREN FIRE ALARM TECHNICIAN TO PERFORM THE OUTAGE.

THE NAVFAC DAHLGREN FIRE ALARM TECHNICIAN WILL IDENTIFY TO THE CONTRACTOR WHAT CIRCUITS HAVE BEEN TAKEN OUT OF SERVICE ONCE THE OUTAGE HAS BEEN MADE. OUTAGES DO NOT INCLUDE CONNECTION OF NEW FIRE ALARM DEVICES, AND/OR WIRING TO EXISTING SYSTEMS, OR PROGRAMMING CHANGES NECESSARY TO ACCOMMODATE NEW

WORK.

CONTRACTOR MUST OBTAIN THE SERVICES, AT CONTRACTORS COST, OF THE EXCLUSIVE GOVERNMENT CONTRACTOR RESPONSIBLE FOR MAINTAINING BASE WIDE MASS NOTIFICATION SYSTEMS, TO PERFORM TIE IN OF NEW WORK AND/OR

REPROGRAMMING OF EXISTING BASE WIDE MASS NOTIFICATION SYSTEMS.

FIRE ALARM NEW WORK LINETYPE

FIRE ALARM EXISTING TO REMAIN LINETYPE

FIRE ALARM DEMOLITION LINETYPE

FIRE ALARM ZONE BOUNDARY

SECURE AREA BOUNDARY, DO NOT PENETRATE

1 HR RATED WALL

FIRE ALARM/MASS NOTIFICATION STROBE, WALL

MOUNTED; XX=CANDELA RATING

FIRE ALARM/MASS NOTIFICATION STROBE,

CEILING MOUNTED; XX=CANDELA RATING

FIRE ALARM/MASS NOTIFICATION

SPEAKER/STROBE APPLIANCE; X=MOUNT,

XX=CANDELA, SA=SELF-AMPLIFIED

FIRE ALARM/MASS NOTIFICATION SPEAKER;

X=MOUNT LOCATION

HORN W/ FIRE ALARM STROBE (EXISTING TO BE

REMOVED); X=MOUNT, XX=CANDELA

FIRE ALARM BELL

SMOKE SENSOR SIGNALING DEVICE; X=LOCATION

A= ABOVE CEILING MOUNT

C= CEILING MOUNT

U= UNDERFLOOR MOUNT

E= ELEVATOR

AIR SAMPLING PORT LOCATION ON CPVC PIPING

NETWORK; X=LOCATION

DUCT SMOKE DETECTOR

MANUAL PULL STATION

VALVE TAMPER SWITCH, CONNECTION ONLY

PRESSURE SWITCH, CONNECTION ONLY

WATER FLOW SWITCH CONNECTION

MULTI-VOLTAGE RELAY

GRAPHIC ANNUNCIATOR PANEL

FIRE ALARM TERMINAL CABINET

GAS DETECTOR, CARBON MONOXIDE

REMOTE TEST STATION

KING FISHER ANTENNA

COMBINATION SMOKE HEAT DETECTOR (EXISTING

TO BE REMOVED); X = MOUNT

FEDERAL SIGNAL ANTENNA

ADDRESSABLE INPUT MODULE

ADDRESSABLE OUTPUT MODULE

HALON ABORT BUTTON (EXISTING TO BE

REMOVED)

120 VAC, 20AMP POWER CIRCUIT

FIRE ALARM/MASS NOTIFICATION CONTROL

PANEL

TRANSIENT VOLTAGE SURGE SUPPRESSOR

REMOTE ANNUNCIATOR PANEL (EXISTING TO BE

REMOVED)

REMOTE ANNUNCIATOR PANEL (LCD DISPLAY)

LOCAL OPERATION CONTROL

NOTIFICATION APPLIANCE PANEL

LED TEXT SIGN

ELEVATOR RECALL TERMINAL CABINET

AMPLIFIER PANEL

ELECTRICAL PANEL (FOR INFORMATION ONLY)

KING FISHER FIRE ALARM REPORTING

TRANSMITTER

FEDERAL SIGNAL MASS NOTIFICATION

TRANSMITTER

ELECTRONIC EQUIPMENT AREA SHUNT TRIP

TERMINAL CABINET (REFER TO DETAIL A1

AND A2 ON SHEET FA-503)

AIR SAMPLING SMOKE DETECTOR

AIR SAMPLING SMOKE DETECTOR POWER

SUPPLY PANEL

CIRCUIT BREAKER

KEY NOTE INDICATOR

FIRE ALARM ZONE IDENTIFIER

DETAIL NUMBER

DETAIL IDENTIFICATION BUBBLE

SHEET DETAIL IS SHOWN ON

SECTION NUMBER

SECTION IDENTIFICATION BUBBLE

SHEET SECTION IS SHOWN ON

AHU

AFF

AHJ

AI

AMP

AR

AWG

BM

C

CKT

CMU

CONC

DN

EG

EMT

EOL

EQUIP

(EX)

FL

FT

GYP

HVAC

IDC

I/F

IN

LAT

LOC

MC

MECH

NEC

NFAC

NFPA

NIC

NO

NTS

OA

P R

RCP

RM

RMC

S

SA

SLC

TYP

UNO

UON

VAC

VDC

W

WP

ZN

AIR HANDLER UNIT

ABOVE FINISHED FLOOR

AUTHORITY HAVING JURISDICTION

ADDRESSABLE INTERFACE

AMPERE

ADDRESSABLE RELAY

AMERICAN WIRE GAUGE

BEAM

CEILING

CIRCUIT

CONCRETE MASONRY UNIT

CONCRETE

DOWN

EQUIPMENT GROUND

ELECTRICAL METALLIC TUBING

END OF LINE SUPERVISION DEVICE

EQUIPMENT

EXISTING

FLOOR

FEET

GYPSUM BOARD

HEATING VENTILATION AIR CONDITIONING

INITIATING DEVICE CIRCUIT

INTERFACE

INCH

LAY-IN ACOUSTICAL TILE

LOCAL OPERATION CONTROL

METAL CLAD

MECHANICAL

NATIONAL ELECTRICAL CODE - NFPA 70

NATIONAL FIRE ALARM CODE - NFPA 72

NATIONAL FIRE PROTECTION ASSOCIATION

NOT IN CONTRACT

NUMBER

NOT TO SCALE

OUTSIDE AIR

PLENUM

RETURN

REMOTE CONTROL PANEL

ROOM

RIGID METAL CONDUIT

SUPPLY

SELF-AMPLIFIED

TERMINAL CABINET

TYPICAL

UNLESS NOTED OTHERWISE

UNLESS OTHERWISE NOTED

VOLTS ALTERNATING CURRENT

VOLTS DIRECT CURRENT

WALL

WEATHERPROOF

ZONE

X

F

FMCP

X

XX

XX

X

XX

VS

XX

S

X

TVSS

LOC

NAP

TEXT

ERTC

ZONE ID

B

AMP

GENERAL NOTES

ABBREVIATION

SYMBOL LIST

AIM

AOM

ELEC

PS

CEILING TYPE LEGEND

CON

GYP

LAT

PSB

SBJ

STL

CONCRETE SLAB AND BEAMS

GYPSUM BOARD ON WOOD OR JOIST

LAY-IN ACOUSTICAL TILE - SUSPENDED

PRESSBOARD

STEEL GRATING ON BAR JOIST OR STEEL

BEAM

STEEL DECK

CEILING TYPE INDICATOR

CEILING HEIGHT

CEILING TYPE - SEE ABBREVIATIONS

AS

X

KING

FEDSIG

ASDP

PSP

A K

A F

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

SO

UT

H

PO

TO

MA

C, D

AH

LG

RE

N, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T W

A S

H I N

G T

V

Y

Y

A R

D

W

A S

H I N

G T

O N

D

C

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

2809 Boston St., Suite 7

Baltimore, MD USA

T 1 443 708 4096

W www.ghd.com

GHD Inc.

4 5

WF

ESTC

MVR

GAP

LCD

FATC

CO

RTS

X

FAA

http://www.ghd.com/

D

EN

SI

TY

SH

EL

VI

NG HI

GH

D

EN

SI

TY

SH

EL

VI

NG

HIGH DENSITY

HIGH DENSITY

ELEC

115B

MECH

115A

MECH

LAB

MECH

LAB

LAB

LAB

VAULT

114A

NMCI

JAN

OFFICE

135A

OFFICE

OFFICE

LIBRARY

CORR.

OFFICE

OFFICE

CORR.

132D

LAB

132A

LAB

BREAK

MEN

WOMEN

140A

MECH

MECH

LAB 155

LAB

LAB

108A

LAB108

LAB

STORAGE

STORAGE

OFFICE

102A

SECURITY

V101 101

LOBBY

OFFICE CORR.

MECH

E101 S101

H101

H102 H103

LAB136A

LAB

H104 H105

S103 160A

MECH

S104

E102

173A

MECH

170A

MECH

V102

LIBRARY

LOBBY

OFFICE

STORAGE

174A

STORAGE

LAB

LAB

LAB

LAB

130A

LAB

S102

H104

OFFICE

CAC-39

CAC-41

CAC-22

CAC-38

CAC-21

CAC-7 CAC-6

CAC-02

CACCAC

CAC

CAC-10

EXTERIOR MECHANICAL YARD

ZONE 1-1

ZONE 1-1

STORAGE

10 SF

BREAK

LAB

LAB

LAB

LAB 214

CONFERENCE

RESTROOM

RESTROOM

JANITOR

E201 206

COPY

ROOM

CONFERENCE

H201

S201

H202

STORAGE

ROOF AREA

LOW ROOF

LOW ROOFS202

236A

LAB

LAB

HALLWAY

241B

OFFICE

241A

OFFICE

233A

OFFICE

OFFICE

MECH

S203 240A

OFFICE

242A

OFFICE

CORR.

OFFICE

CORR.

HALLWAY

244A

OFFICE

OFFICE

CORR.

246B

OFFICE

246C

OFFICE

246D

OFFICE

H207

OFFICE

246A

OFFICE

250C

OFFICE

250B

OFFICE

250A

OFFICE

OFFICE

OFFICE

OFFICE

STORAGE

E202

S204266

OFFICE

CORR.

H205

OFFICE

CORR.

KITCHEN

CONFERENCE

OFFICE CORR.

267A

OFFICE

CORR.

CLOSET

MEN

WOMEN

JAN.

0B

OF

FI

CE

H204

4A

ST

OR

AG

E

2A

ST

OR

AG

E

METAL

STAIRS

WITH

HANDRAILS

T-1

MDP-1

STORAGE

CA

C-

CAC-32

CAC-33

CA

C-

CRU-6

CRU-1 CRU-2 CRU-3

CRU-4

ZONE 2-1

ZONE 2-2

ZONE 2-1

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/8

/20

9:

:27 A

M

1.5

4_

FA

-0

.D

W G

MCP ACJ MTS

F I R

E

A

L A

O

V

O

Z

N

I N

G

P

L A

N

13112633

FA-002

SCALE: NOT TO SCALE

FIRE ALARM FIRST FLOOR ZONING PLAN

SCALE: NOT TO SCALE

FIRE ALARM SECOND FLOOR ZONING PLAN

FIRE ALARM ZONE BOUNDARY

FIRE ALARM ZONE IDENTIFIER

LEGEND:

SHEET NOTES

1. ZONING PLANS ILLUSTRATE THE SIZE AND BOUNDARIES OF

EACH FIRE ALARM SYSTEM ZONE AFTER NEW WORK.

2. ELECTRONIC EQUIPMENT ROOMS WILL HAVE A DEDICATED

FIRE ALARM ZONE. REFER TO FLOOR PLANS FOR THE

LOCATION OF EQUIPMENT.

ZONE ID

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

SO

UT

H

PO

TO

MA

C, D

AH

LG

RE

N, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T W

A S

H I N

G T

V

Y

Y

A R

D

W

A S

H I N

G T

O N

D

C

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

2809 Boston St., Suite 7

Baltimore, MD USA

T 1 443 708 4096

W www.ghd.com

GHD Inc.

4 5

D

EN

SI

TY

SH

EL

VI

NG HI

GH

D

EN

SI

TY

SH

EL

VI

NG

HIGH DENSITY

HIGH DENSITY

ELEC

115B

MECH

115A

MECH

LAB

MECH

LAB

LAB

LAB

VAULT

114A

NMCI

JAN

OFFICE

135A

OFFICE

OFFICE

LIBRARY

CORR.

OFFICE

OFFICE

CORR.

132D

LAB

132A

LAB

BREAK

MEN

WOMEN

140A

MECH

MECH

LAB 155

LAB

LAB

108A

LAB108

LAB

STORAGE

STORAGE

OFFICE

102A

SECURITY

V101 101

LOBBY

OFFICE CORR.

MECH

E101 S101

H101

H102 H103

LAB136A

LAB

H104 H105

S103 160A

MECH

S104

E102

173A

MECH

170A

MECH

V102

LIBRARY

LOBBY

OFFICE

STORAGE

174A

STORAGE

LAB

LAB

LAB

LAB

130A

LAB

S102

H104

OFFICE

CAC-39

CAC-41

CAC-22

CAC-38

CAC-21

CAC-7 CAC-6

CAC-02

CACCAC

CAC

CAC-10

EXTERIOR MECHANICAL YARD

ZONE 1-E1

ZONE 1-E2

ZONE 1-E3

ZONE 1-E4

ZONE 1-E5

ZONE 1-E6

STORAGE

10 SF

BREAK

LAB

LAB

LAB

LAB 214

CONFERENCE

RESTROOM

RESTROOM

JANITOR

E201 206

COPY

ROOM

CONFERENCE

H201

S201

H202

STORAGE

ROOF AREA

LOW ROOF

LOW ROOFS202

236A

LAB

LAB

HALLWAY

METAL

STAIRS

WITH

HANDRAILS

T-1

MDP-1

STORAGE

CA

C-

CAC-32

CAC-33

CA

C-

CRU-6

CRU-1 CRU-2 CRU-3

CRU-4

ZONE 2-E2

ZONE 2-E3

ZONE 2-E4

ZONE 2-E5

ZONE 2-E1

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/8

/20

9:

:32 A

M

1.5

4_

FA

-0

.D

W G

MCP ACJ MTS

F I R

E

A

L A

O

V

O

N

I N

G

P

L A

N

13112634

FA-003

SCALE: NOT TO SCALE

FIRE ALARM FIRST FLOOR ABOVE FLOOR AIR SAMPLING DETECTION ZONING PLAN

SCALE: NOT TO SCALE

FIRE ALARM SECOND FLOOR ABOVE FLOOR AIR SAMPLING DETECTION ZONING PLAN

FIRE ALARM ZONE BOUNDARY

NON-HATCHED AREA REPRESENTS FIRE ALARM

ZONE OF NON-ELECTRONIC EQUIPMENT ROOMS

HATCHED AREA REPRESENTS FIRE ALARM ZONE OF

AN ELECTRONIC EQUIPMENT ROOM

FIRE ALARM ZONE IDENTIFIER

LEGEND:

SHEET NOTES

1. ZONING PLANS ILLUSTRATE THE SIZE AND BOUNDARIES OF

EACH FIRE ALARM SYSTEM ZONE AFTER NEW WORK.

2. ELECTRONIC EQUIPMENT ROOMS WILL HAVE A DEDICATED

FIRE ALARM ZONE. REFER TO FLOOR PLANS FOR THE

LOCATION OF EQUIPMENT.

ZONE ID

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

SO

UT

H

PO

TO

MA

C, D

AH

LG

RE

N, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T W

A S

H I N

G T

V

Y

Y

A R

D

W

A S

H I N

G T

O N

D

C

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

2809 Boston St., Suite 7

Baltimore, MD USA

T 1 443 708 4096

W www.ghd.com

GHD Inc.

D

EN

SI

TY

SH

EL

VI

NG HI

GH

D

EN

SI

TY

SH

EL

VI

NG

HIGH DENSITY

HIGH DENSITY

ELEC

115B

MECH

115A

MECH

LAB

MECH

LAB

LAB

LAB

VAULT

114A

NMCI

JAN

OFFICE

135A

OFFICE

OFFICE

LIBRARY

CORR.

OFFICE

OFFICE

CORR.

132D

LAB

132A

LAB

BREAK

MEN

WOMEN

140A

MECH

MECH

LAB 155

LAB

LAB

108A

LAB108

LAB

STORAGE

STORAGE

OFFICE

102A

SECURITY

V101 101

LOBBY

OFFICE CORR.

MECH

E101 S101

H101

H102 H103

LAB136A

LAB

H104 H105

S103 160A

MECH

S104

E102

173A

MECH

170A

MECH

V102

LIBRARY

LOBBY

OFFICE

STORAGE

174A

STORAGE

LAB

LAB

LAB

LAB

130A

LAB

S102

H104

OFFICE

CAC-39

CAC-41

CAC-22

CAC-38

CAC-21

CAC-7 CAC-6

CAC-02

CACCAC

CAC

CAC-10

EXTERIOR MECHANICAL YARD

ZONE 1-U1

ZONE 1-U2

ZONE 1-U3

ZONE 1-U4

STORAGE

10 SF

BREAK

LAB

LAB

LAB

LAB 214

CONFERENCE

RESTROOM

RESTROOM

JANITOR

E201 206

COPY

ROOM

CONFERENCE

H201

S201

H202

STORAGE

ROOF AREA

LOW ROOF

LOW ROOFS202

236A

LAB

LAB

HALLWAY

METAL

STAIRS

WITH

HANDRAILS

T-1

MDP-1

STORAGE

CA

C-

CAC-32

CAC-33

CA

C-

CRU-6

CRU-1 CRU-2 CRU-3

CRU-4

ZONE 2-U3

ZONE 2-U1

ZONE 2-U2

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/8

/20

9:

:36 A

M

1.5

4_

FA

-0

.D

W G

MCP ACJ MTS

F I R

E

A

L A

U

D

O

N

I N

G

P

L A

N

13112635

FA-004

SCALE: NOT TO SCALE

FIRE ALARM FIRST FLOOR UNDER FLOOR AIR SAMPLING DETECTION ZONING PLAN

SCALE: NOT TO SCALE

FIRE ALARM SECOND FLOOR UNDER FLOOR AIR SAMPLING DETECTION ZONING PLAN

FIRE ALARM ZONE BOUNDARY

NON-HATCHED AREA REPRESENTS FIRE ALARM

ZONE OF NON-ELECTRONIC EQUIPMENT ROOMS

HATCHED AREA REPRESENTS FIRE ALARM ZONE OF

AN ELECTRONIC EQUIPMENT ROOM

FIRE ALARM ZONE IDENTIFIER

LEGEND:

SHEET NOTES

1. ZONING PLANS ILLUSTRATE THE SIZE AND BOUNDARIES OF

EACH FIRE ALARM SYSTEM ZONE AFTER NEW WORK.

2. ELECTRONIC EQUIPMENT ROOMS WILL HAVE A DEDICATED

FIRE ALARM ZONE. REFER TO FLOOR PLANS FOR THE

LOCATION OF EQUIPMENT.

ZONE ID

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

SO

UT

H

PO

TO

MA

C, D

AH

LG

RE

N, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T W

A S

H I N

G T

V

Y

Y

A R

D

W

A S

H I N

G T

O N

D

C

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

2809 Boston St., Suite 7

Baltimore, MD USA

T 1 443 708 4096

W www.ghd.com

GHD Inc.

HIGH DENSITY

ELEC

115B

MECH

115A

MECH

LAB

MECH

LAB

LAB

LAB

VAULT

114A

NMCI

JAN

OFFICE

135A

OFFICE

OFFICE

LIBRARY

CORR.

OFFICE

OFFICE

CORR.

132D

LAB

132A

LAB

BREAK

MEN

WOMEN

140A

MECH

MECH

LAB

LAB

108A

LAB108

LAB

STORAGE

STORAGE

OFFICE

102A

SECURITY

V101 101

LOBBY

OFFICE CORR.

MECH

E101 S101

H101

H102 H103

H104

LAB

130A

LAB

S102

H104

C

CC

C

C

C C

C

C

C

C

C

C

C

C

W

C

C

CC

C

CC

C

C

W

W W

W

W W W

F

PAD-3 FACP KING MXL

K I N

G

FAA

W

VSVS

VS

VS

WF

WF

DUAL

AIM

DUAL

AIM

W

W W

W

W

C

C

C

C

C

C

C

C C

C C

CC

CC

C

F

F

FACP

C C

C C

C C

C

C

C

C

C

C

C

C

C

C

C

C

C

CCC

CCC

CCC

A

L O

N

W

H A

L

BB

B F

C

C

C

C

C

CC

CC

C

C

C

C

C

C C

C

W

HALON

PS

PSVS

B

FAA

AIM

AIM

AIM

AIM

AIM

AIM

VS

WF

VS

WF

AK

VS

WF

AIM

AIM

MATCHLINE

MATCHLINE

M A

T C

H L I N

E M

A T

C H

L I N

E M

A T

C H

L I N

E

M A

T C

H L I N

E M

A T

C H

L I N

E

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/8

/20

9:

:42 A

M

1.5

4_

FA

-1

.D

W G

MCP ACJ MTS

F I R

E

A

L A

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

13112636

FA-101

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

SO

UT

H

PO

TO

MA

C, D

AH

LG

RE

N, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T W

A S

H I N

G T

V

Y

Y

A R

D

W

A S

H I N

G T

O N

D

C

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

2809 Boston St., Suite 7

Baltimore, MD USA

T 1 443 708 4096

W www.ghd.com

GHD Inc.

4 5

GRAPHIC SCALE

GRAPHIC SCALES MUST BE USED.

CAUTION: IF THIS DRAWING IS A REDUCTION,

8'8' 4' 0 16' 1/8"=1'-0"

SHEET NOTES

N

SCALE: 1/8" = 1' - 0"

FIRE ALARM FIRST FLOOR DEMOLITION PLAN - AREA-A

1. ALL EXISTING FIRE ALARM DEVICES SHALL

REMAIN IN SERVICE DURING

INSTALLATION OF THE NEW FIRE ALARM

EQUIPMENT. THE EXISTING SYSTEM

SHALL REMAIN IN SERVICE UNTIL THE

NEW SYSTEM HAS BEEN INSTALLED,

PROGRAMMED, TESTED AND APPROVED.

2. ONCE THE NEW SYSTEM HAS BEEN

PLACED INTO SERVICE, REMOVE ALL

EXISTING FIRE ALARM DEVICES AS

INDICATED ON THE DRAWINGS.

DISCONNECT AND REMOVE ALL WIRING

AND RACEWAYS THAT SERVE EXISTING

FIRE ALARM COMPONENTS.

3. PATCH AND PAINT DISTURBED AREAS TO

MATCH EXISTING CONDITIONS.

KEYPLAN

A

C

D

EN

SI

TY

SH

EL

VI

NG HI

GH

D

EN

SI

TY

SH

EL

VI

NG

LAB

H105

S103 160A

MECH

S104

E102

173A

MECH

170A

MECH

V102

LIBRARY

LOBBY

OFFICE

STORAGE

174A

STORAGE

LAB

LAB

LAB

H104

OFFICE

EXTERIOR MECHANICAL YARD

C

A

L O

N

W

H A

L

F

VS

WF

C

C C

C

C

C

C

W

HALON

W

HALON

H

B

FAA

HALON

FACP

C C

C C

C

C

C C

C C

C C

C C

C C

C C

C C

C C

W

HALON

B

W

H A

L O

N

H A

L O

N

W

HALON

W

HALON

HALON

VS

WF

VS

WF

B

C

C

C

C

C

C

AIM

AIM

AIM

AIM

AIM

AIM

AIM

AIM

AIM ERTC

C

M A

T C

H L I N

E M

A T

C H

L I N

E M

A T

C H

L I N

E

M A

T C

H L I N

E M

A T

C H

L I N

E

LAB136A

LAB

CC

F

C

C

C

C

W W

MATCHLINE

MATCHLINE

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/8

/20

9:

:46 A

M

1.5

4_

FA

-1

.D

W G

MCP ACJ MTS

F I R

E

A

L A

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

13112637

FA-102

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

SO

UT

H

PO

TO

MA

C, D

AH

LG

RE

N, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T W

A S

H I N

G T

V

Y

Y

A R

D

W

A S

H I N

G T

O N

D

C

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

2809 Boston St., Suite 7

Baltimore, MD USA

T 1 443 708 4096

W www.ghd.com

GHD Inc.

4 5

GRAPHIC SCALE

GRAPHIC SCALES MUST BE USED.

CAUTION: IF THIS DRAWING IS A REDUCTION,

8'8' 4' 0 16' 1/8"=1'-0"

SHEET NOTES

N

SCALE: 1/8" = 1' - 0"

FIRE ALARM FIRST FLOOR DEMOLITION PLAN - AREA-B

1. ALL EXISTING FIRE ALARM DEVICES SHALL

REMAIN IN SERVICE DURING

INSTALLATION OF THE NEW FIRE ALARM

EQUIPMENT. THE EXISTING SYSTEM

SHALL REMAIN IN SERVICE UNTIL THE

NEW SYSTEM HAS BEEN INSTALLED,

PROGRAMMED, TESTED AND APPROVED.

2. ONCE THE NEW SYSTEM HAS BEEN

PLACED INTO SERVICE, REMOVE ALL

EXISTING FIRE ALARM DEVICES AS

INDICATED ON THE DRAWINGS.

DISCONNECT AND REMOVE ALL WIRING

AND RACEWAYS THAT SERVE EXISTING

FIRE ALARM COMPONENTS.

3. PATCH AND PAINT DISTURBED AREAS TO

MATCH EXISTING CONDITIONS.

KEYPLAN

A

C

B

N

SCALE: 1/8" = 1' - 0"

FIRE ALARM FIRST FL. DEMOLITION PLAN - AREA-C

ELEC

115B

MECH

115A

MECH

LAB

MECH

LAB

LAB

LAB

VAULT

114A

NMCI

JAN

OFFICE

135A

OFFICE

OFFICE

LIBRARY

CORR.

OFFICE

OFFICE

CORR.

132D

LAB

132A

LAB

BREAK

MEN

WOMEN

140A

MECH

MECH

LAB

LAB

108A

LAB108

LAB

STORAGE

STORAGE

OFFICE

102A

SECURITY

V101 101

LOBBY

OFFICE CORR.

MECH

E101 S101

H101

H102 H103

H104

LAB

130A

LAB

S102

H104

MATCHLINE

MATCHLINE

M A

T C

H L I N

E M

A T

C H

L I N

E M

A T

C H

L I N

E

M A

T C

H L I N

E M

A T

C H

L I N

E

U

U

U U

U

U U U

U

U

U

U

U U U U

U U U U

U U U U

U U U U

U U U U

UU

UU

UU

UU

U U U

UU

U

U

U U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U

U U

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/8

/20

9:

:51 A

M

1.5

4_

FA

-1

.D

W G

MCP ACJ MTS

F I R

E

A

L A

U

N D

D

E M

O

P

L A

N

A

R E

A

13112638

FA-103

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

SO

UT

H

PO

TO

MA

C, D

AH

LG

RE

N, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T W

A S

H I N

G T

V

Y

Y

A R

D

W

A S

H I N

G T

O N

D

C

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

2809 Boston St., Suite 7

Baltimore, MD USA

T 1 443 708 4096

W www.ghd.com

GHD Inc.

4 5

GRAPHIC SCALE

GRAPHIC SCALES MUST BE USED.

CAUTION: IF THIS DRAWING IS A REDUCTION,

8'8' 4' 0 16' 1/8"=1'-0"

SHEET NOTES

N

SCALE: 1/8" = 1' - 0"

FIRE ALARM FIRST FLOOR UNDERFLOOR DEMOLITION PLAN - AREA-A

1. ALL EXISTING FIRE ALARM DEVICES SHALL

REMAIN IN SERVICE DURING

INSTALLATION OF THE NEW FIRE ALARM

EQUIPMENT. THE EXISTING SYSTEM

SHALL REMAIN IN SERVICE UNTIL THE

NEW SYSTEM HAS BEEN INSTALLED,

PROGRAMMED, TESTED AND APPROVED.

2. ONCE THE NEW SYSTEM HAS BEEN

PLACED INTO SERVICE, REMOVE ALL

EXISTING FIRE ALARM DEVICES AS

INDICATED ON THE DRAWINGS.

DISCONNECT AND REMOVE ALL WIRING

AND RACEWAYS THAT SERVE EXISTING

FIRE ALARM COMPONENTS.

3. PATCH AND PAINT DISTURBED AREAS TO

MATCH EXISTING CONDITIONS.

KEYPLAN

A

C

D

EN

SI

TY

SH

EL

VI

NG HI

GH

D

EN

SI

TY

SH

EL

VI

NG

LAB

H105

S103 160A

MECH

S104

E102

173A

MECH

170A

MECH

V102

LIBRARY

LOBBY

OFFICE

STORAGE

174A

STORAGE

LAB

LAB

LAB

H104

OFFICE

EXTERIOR MECHANICAL YARD

M

A T

C H

L I N

E M

A T

C H

L I N

E M

A T

C H

L I N

E

M A

T C

H L I N

E M

A T

C H

L I N

E

LAB136A

LAB

MATCHLINE

MATCHLINE

UU

U U

U U

U U

U U

U

U

U

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/8

/20

9:

:56 A

M

1.5

4_

FA

-1

.D

W G

MCP ACJ MTS

F I R

E

A

L A

U

N D

D

E M

O

P

L A

N

A

R E

A

13112639

FA-104

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

SO

UT

H

PO

TO

MA

C, D

AH

LG

RE

N, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T W

A S

H I N

G T

V

Y

Y

A R

D

W

A S

H I N

G T

O N

D

C

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

2809 Boston St., Suite 7

Baltimore, MD USA

T 1 443 708 4096

W www.ghd.com

GHD Inc.

4 5

GRAPHIC SCALE

GRAPHIC SCALES MUST BE USED.

CAUTION: IF THIS DRAWING IS A REDUCTION,

8'8' 4' 0 16' 1/8"=1'-0"

SHEET NOTES

N

SCALE: 1/8" = 1' - 0"

FIRE ALARM FIRST FLOOR UNDERFLOOR DEMOLITION PLAN - AREA-B

1. ALL EXISTING FIRE ALARM DEVICES SHALL

REMAIN IN SERVICE DURING

INSTALLATION OF THE NEW FIRE ALARM

EQUIPMENT. THE EXISTING SYSTEM

SHALL REMAIN IN SERVICE UNTIL THE

NEW SYSTEM HAS BEEN INSTALLED,

PROGRAMMED, TESTED AND APPROVED.

2. ONCE THE NEW SYSTEM HAS BEEN

PLACED INTO SERVICE, REMOVE ALL

EXISTING FIRE ALARM DEVICES AS

INDICATED ON THE DRAWINGS.

DISCONNECT AND REMOVE ALL WIRING

AND RACEWAYS THAT SERVE EXISTING

FIRE ALARM COMPONENTS.

3. PATCH AND PAINT DISTURBED AREAS TO

MATCH EXISTING CONDITIONS.

KEYPLAN

A

C

B

N

SCALE: 1/8" = 1' - 0"

FIRE ALARM FIRST FLOOR UNDERFLOOR

DEMOLITION PLAN - AREA-C

KEY NOTES

NO EXISTING UNDER FLOOR DETECTION

LOCATED WITHIN THIS SPACE.

BREAK

LAB

LAB

LAB

LAB 214

CONFERENCE

RESTROOM

RESTROOM

JANITOR

E201 206

COPY

ROOM

CONFERENCE

H201

S201

H202

STORAGE

ROOF AREA

LOW ROOF

LOW ROOFS202

HALLWAY

241B

OFFICE

MEN

MDP-1

STORAGE

MATCHLINE

MATCHLINE

M A

T C

H L I N

E M

A T

C H

L I N

E M

A T

C H

L I N

E

M A

T C

H L I N

E M

A T

C H

L I N

E

CC

CC

CC

CC

CC

W W

W

W

W W

W

W

W

W W

C C

C C

C C

C C

C C

C C

C C

C

C

C

C

C

CC

CCC

WFVS

WF

VS

WF

VS

WF

VS

WFVS

WFVS

WFVS

C

C

RTS

AIM

RTS

AIMAIMAIMAIM

A I M

R T

S

C C

AIM

AIM

AIM

AIM

AIM AIM

AIM AIM

AIM AIM

AIM

AIM

AIM

AIM

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/8

/20

9:

:02 A

M

1.5

4_

FA

-1

.D

W G

MCP ACJ MTS

F I R

E

A

L A

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

13112640

FA-105

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

SO

UT

H

PO

TO

MA

C, D

AH

LG

RE

N, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T W

A S

H I N

G T

V

Y

Y

A R

D

W

A S

H I N

G T

O N

D

C

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

2809 Boston St., Suite 7

Baltimore, MD USA

T 1 443 708 4096

W www.ghd.com

GHD Inc.

4 5

GRAPHIC SCALE

GRAPHIC SCALES MUST BE USED.

CAUTION: IF THIS DRAWING IS A REDUCTION,

8'8' 4' 0 16' 1/8"=1'-0"

SHEET NOTES

N

SCALE: 1/8" = 1' - 0"

FIRE ALARM SECOND FLOOR DEMOLITION PLAN - AREA-A

1. ALL EXISTING FIRE ALARM DEVICES SHALL

REMAIN IN SERVICE DURING

INSTALLATION OF THE NEW FIRE ALARM

EQUIPMENT. THE EXISTING SYSTEM

SHALL REMAIN IN SERVICE UNTIL THE

NEW SYSTEM HAS BEEN INSTALLED,

PROGRAMMED, TESTED AND APPROVED.

2. ONCE THE NEW SYSTEM HAS BEEN

PLACED INTO SERVICE, REMOVE ALL

EXISTING FIRE ALARM DEVICES AS

INDICATED ON THE DRAWINGS.

DISCONNECT AND REMOVE ALL WIRING

AND RACEWAYS THAT SERVE EXISTING

FIRE ALARM COMPONENTS.

3. PATCH AND PAINT DISTURBED AREAS TO

MATCH EXISTING CONDITIONS.

KEYPLAN

A

C

241B

OFFICE

241A

OFFICE

233A

OFFICE

OFFICE

MECH

S203 240A

OFFICE

242A

OFFICE

CORR.

OFFICE

CORR.

HALLWAY

244A

OFFICE

OFFICE

CORR.

246B

OFFICE

246C

OFFICE

246D

OFFICE

H207

OFFICE

246A

OFFICE

250C

OFFICE

250B

OFFICE

250A

OFFICE

OFFICE

OFFICE

OFFICE

STORAGE

E202

S204266

OFFICE

CORR.

H205

OFFICE

CORR.

KITCHEN

CONFERENCE

OFFICE CORR.

267A

OFFICE

CORR.

CLOSET

MEN

WOMEN

JAN.

0B

OF

FI

CE

H204

4A

ST

OR

AG

E

2A

ST

OR

AG

E

C

C

C

C

C

C C

C

C

C

C

C

C

C

C

R T

S

R T

S

WF

VS

AIM

AIM

C

M A

T C

H L I N

E M

A T

C H

L I N

E M

A T

C H

L I N

E

M A

T C

H L I N

E M

A T

C H

L I N

E

CONFERENCE

236A

LAB

LAB

C

C

C

C

C

C

C

W

W

W

RTS

AIM

RTS

AIMAIMAIMAIM

A I M

A I M

A I M

A I M

RTS RTS RTS RTS

R T

S

MATCHLINE

MATCHLINE

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/8

/20

9:

:07 A

M

1.5

4_

FA

-1

.D

W G

MCP ACJ MTS

F I R

E

A

L A

D

E M

O L

I T

I O

N

P

L A

N

A

R E

A

13112641

FA-106

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

SO

UT

H

PO

TO

MA

C, D

AH

LG

RE

N, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T W

A S

H I N

G T

V

Y

Y

A R

D

W

A S

H I N

G T

O N

D

C

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

2809 Boston St., Suite 7

Baltimore, MD USA

T 1 443 708 4096

W www.ghd.com

GHD Inc.

4 5

GRAPHIC SCALE

GRAPHIC SCALES MUST BE USED.

CAUTION: IF THIS DRAWING IS A REDUCTION,

8'8' 4' 0 16' 1/8"=1'-0"

SHEET NOTES

N

SCALE: 1/8" = 1' - 0"

FIRE ALARM SECOND FLOOR DEMOLITION PLAN - AREA-B

1. ALL EXISTING FIRE ALARM DEVICES SHALL

REMAIN IN SERVICE DURING

INSTALLATION OF THE NEW FIRE ALARM

EQUIPMENT. THE EXISTING SYSTEM

SHALL REMAIN IN SERVICE UNTIL THE

NEW SYSTEM HAS BEEN INSTALLED,

PROGRAMMED, TESTED AND APPROVED.

2. ONCE THE NEW SYSTEM HAS BEEN

PLACED INTO SERVICE, REMOVE ALL

EXISTING FIRE ALARM DEVICES AS

INDICATED ON THE DRAWINGS.

DISCONNECT AND REMOVE ALL WIRING

AND RACEWAYS THAT SERVE EXISTING

FIRE ALARM COMPONENTS.

3. PATCH AND PAINT DISTURBED AREAS TO

MATCH EXISTING CONDITIONS.

KEYPLAN

A

C

B

N

SCALE: 1/8" = 1' - 0"

FIRE ALARM SECOND FL. DEMOLITION PLAN - AREA-C

BREAK

LAB

LAB

LAB

LAB 214

CONFERENCE

RESTROOM

RESTROOM

JANITOR

E201 206

COPY

ROOM

CONFERENCE

H201

S201

H202

STORAGE

ROOF AREA

LOW ROOF

LOW ROOFS202

HALLWAY

241B

OFFICE

MEN

MDP-1

STORAGE

MATCHLINE

MATCHLINE

M A

T C

H L I N

E M

A T

C H

L I N

E M

A T

C H

L I N

E

M A

T C

H L I N

E M

A T

C H

L I N

E

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U U

U

U U

U U

U

U

U

U U

UU

U U

U U

FI

LE

N

RE

F:

PL

OT

D

AT

E:

8/8

/20

9:

:12 A

M

1.5

4_

FA

-1

.D

W G

MCP ACJ MTS

F I R

E

A

L A

U

N D

D

E M

O

P

L A

N

A

R E

A

13112641

FA-107

A

B

C

D

2 3 4 5

1 2 3

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

OF

EPROJECT NO.:

AS NOTED

1558920

<<PM/DM>> DMITRIYEV E. EASLEY

BRANCH MANAGER: ARTHUR V. LOVING

CHIEF ENG/ARCH: ARTHUR V. LOVING

<<XX>>

D E

P A

R T

M E

T

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

NA

VA

L S

UP

PO

RT

F

AC

ILI

TY

D

AH

LG

RE

N

SO

UT

H

PO

TO

MA

C, D

AH

LG

RE

N, V

A

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

A S

H I N

G T

O N

P U

B L

R

P

A R

T M

E N

T W

A S

H I N

G T

V

Y

Y

A R

D

W

A S

H I N

G T

O N

D

C

F I R

E

P

R O

T E

C T

I O

N

U

P G

R A

D E

S

I N

B U

I L

D I N

G

7900 Westpark Dr. | Suite A405 | McLean, VA 22102

(703) 556-8820 | www.summerconsultants.com

SUMMER

CONSULTANTS

I N C O R P O R A T E D

2809 Boston St., Suite 7

Baltimore, MD USA

T 1 443 708 4096

W www.ghd.com

GHD Inc.

4 5

GRAPHIC SCALE

GRAPHIC SCALES MUST BE USED.

CAUTION: IF THIS DRAWING IS A REDUCTION,

8'8' 4' 0 16' 1/8"=1'-0"

SHEET NOTES

N

SCALE: 1/8" = 1' - 0"

FIRE ALARM SECOND FLOOR UNDERFLOOR DEMOLITION PLAN - AREA-A

1. ALL EXISTING FIRE ALARM DEVICES SHALL

REMAIN IN SERVICE DURING

INSTALLATION OF THE NEW FIRE ALARM

EQUIPMENT. THE EXISTING SYSTEM

SHALL REMAIN IN SERVICE UNTIL THE

NEW SYSTEM HAS BEEN INSTALLED,

PROGRAMMED, TESTED AND APPROVED.

2. ONCE THE NEW SYSTEM HAS BEEN

PLACED INTO SERVICE, REMOVE ALL

EXISTING FIRE ALARM DEVICES AS

INDICATED ON THE DRAWINGS.

DISCONNECT AND REMOVE ALL WIRING

AND RACEWAYS THAT SERVE EXISTING

FIRE ALARM COMPONENTS.

3. PATCH AND PAINT DISTURBED AREAS TO

MATCH EXISTING CONDITIONS.

KEYPLAN

A

C

241A

OFFICE

233A

OFFICE

OFFICE

MECH

S203 240A

OFFICE

242A

OFFICE

CORR.

OFFICE

CORR.

HALLWAY

244A

OFFICE

OFFICE

CORR.

246B

OFFICE

246C

OFFICE

246D

OFFICE

H207

OFFICE

246A

OFFICE

250C

OFFICE

250B

OFFICE

250A

OFFICE

OFFICE

OFFICE

OFFICE

STO…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .