This document is a Description of Requirement (DOR) for an Environmental Chamber for Soil Additive Testing. The U.S. Army Engineer Research and Development Center (ERDC) Geotechnical and Structures Laboratory (GSL) requires one Cincinnati Sub Zero (CSZ) Model ZPH-8-2-SCT/AC Temperature/Humidity Test Chamber with Tundra system capable of performing extreme temperature and humidity cycling. The chamber must be automated with appropriate data collection software, and shipping and installation costs must be included. The DOR provides detailed specifications for the required equipment, including temperature range, humidity range, pull-down and heat-up performance, and other features.

The related federal contract opportunity is a Request for Quote (RFQ) under Solicitation Number W912HZ22Q1218, issued by the U.S. Army Corps of Engineers ERDC. The requirement is unrestricted under NAICS Code 334519, with a size standard of 600 employees. Offers are due by June 11, 2024, and the Government intends to evaluate offers and award a contract without discussions. The award will be made to the responsible offeror with the Lowest Price that is determined to meet the minimum technical requirements.

View the file

Other files

File Type Posted
Question_Answer.pdf PDF
A02.08_Brand Name Justification.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Description of Requirement

Environmental Chamber for Soil Additive Testing

The Geotechnical and Structures Laboratory (GSL) of the U.S. Army Engineer Research and Development Center (ERDC) at Waterways Experiment Station requires one Cincinnati Sub Zero (CSZ) Model ZPH-8-2-SCT/AC Temperature/Humidity Test Chamber with Tundra system capable of performing extreme temperature and humidity cycling. A complete testing system capable of performing both tests is required. The testing equipment must be automated with appropriate data collection software.

Shipping and installation costs must be included in the proposal.

Basic equipment and ancillary components required for the CSZ Model ZPH-8-2-SCT/AC Temperature/Humidity Test Chamber to meet the above requirements are as follows:

Measurement Components

Quantity 1: Cabinet Items

• One (1) 17.75" (451 mm) high x 10.75" (273 mm) wide fog-free heated viewing window

• Single-handed, lockable door latch

• Heavy duty casters, 3" wheel and leveling legs

• Chamber pressure relief/equalization vent

• Two (2) 4" (102 mm) circular access ports, centered on the right-hand side and left hand-side of the chamber (additional ports optional)

• One (1) adjustable, slide-out stainless-steel shelf with two (2) support brackets on 2" centers (additional shelves optional)

Quantity 1: Electrical Items

• Safety relay to protect your device under test by removing power to it when the chamber is not running.

• UL-508A listed sub-panel.

• Interior Chamber Light

Quantity 1: Refrigeration Items

• 2HP R-410A Tundra Refrigeration System

• Scroll Tundra, Integral Air-Cooled Condenser

• Liquid filled refrigeration gauges and refrigeration service taps for ease of servicing.

Quantity 1: Instrument Items

• EZT-570 7" touch screen controller

• Solid state humidity sensor

Quantity 1: Temperature

• -45°C to +190°C (-49°F to +375°F) Temperature Range

• ±0.5°C (±1°F); ±3% relative humidity at steady state conditions after stabilization.

• Chamber airflow of 315 CFM

• Temperature Performance:

Pull-Down Performance:

+24°C (+75°F) to -18°C (0°F) in 6 minutes +24°C (+75°F) to -34°C (-30°F) in 12 minutes +24°C (+75°F) to -40°C (-40°F) in 18 minutes +85°C (+185°F) to -40°C (-40°F) in 30 minutes Heat-Up Performance:

+24°C (+75°F) to +93°C (+200°F) in 10 minutes +24°C (+75°F) to +190°C (+375°F) in 30 minutes -34°C (-30°F) to +24°C (+75°F) in 10 minutes

Quantity 1: Humidity

10% to 98% relative humidity as limited by a +85°C (+185°F) maximum dry bulb and a +7°C

(+45°F) minimum dewpoint. Approximate humidity consumption: .5 gallon of water per hour dependent upon live load.

Quantity 1: Cabinet

• One (1) 17.75" (451 mm) high x 10.75" (273 mm) wide fog-free heated viewing window

• Single-handed, lockable door latch

• Heavy duty casters, 3" wheel and leveling legs

• Chamber pressure relief/equalization vent

• Two (2) 4" (102 mm) circular access ports, centered on the right-hand side and left hand-side of the chamber.

• One (1) adjustable, slide-out stainless-steel shelf with two (2) support brackets on 2" centers

Quantity 1: Electrical

• Safety relay to protect your device under test by removing power to it when the chamber is not running.

• UL-508A listed sub-panel.

• Interior Chamber Light

Quantity 1: Refrigeration

• 2HP R-410A Tundra Refrigeration System

• Scroll Tundra, Integral Air-Cooled Condenser

• Liquid filled refrigeration gauges and refrigeration service taps for ease of servicing

Quantity 1: Instruments

• EZT-570 7" touch screen controller

• Solid state humidity sensor

Quantity 1: Controller

• Touch Panel 7” (178mm) Ergonomic height

• Program Controller Start parameters for programs: start, stop, pause, delayed autostart, Program ramp steps entering time or °C/min, 99 steps, 1,000 cycles maximum. Profile status view.

• PID controller

Special control algorithms, define/change per output demands.

• Data-Logging Custom file names, batch/lot numbers, operator notes & digital signatures.

• File Management/Email Easily download profiles, alarm files, audit trail files and data files to USB stick. Also import profiles for easy transfer among multiple chambers. Email data, alarm history & audit trail files directly from the controller with a touch of a button.

• Switch Inputs (Digital) 8 inputs for configuring controller functions

• Switch Outputs (Digital) 15 event outputs with connection panel & plug connectors

• Product Control Accelerates temperature cycling of the device under test.

• Password Protection 3 levels of security

• Diagnostic System Fully configurable alarm settings and maintenance alerts

• Communication Control by Ethernet TCP/IP and EIA-232

• Ethernet Interface Remotely monitor and control with VNC Server

• Multi-Language Display Configurable for 10+ different languages

Quantity 1: Add Ons

• Startup and Training

• Shelf

• Customer event option for EZT controller

• Running time meter

• Humidity water demineralizer filtration assembly

• Extra demineralizer cartridge

• Recirculating humidity water supply system that includes humidity water demineralizer filtration system

• EZ-View software

• EZT Monitor package

• Hardcopy manual set, printed and bound

• Emergency Stop Button

• IPPC closed crate

• 2-year parts and labor warranty

Delivery Date: Must be delivered no later than 26 weeks after award

Delivery Location: Engineer Research and Development Center Geotechnical and Structures Laboratory 3909 Halls Ferry Rd

Vicksburg, MS 39180