Development of a modular, drive-by-wire, haptic controlled, reusable colonoscope system - the united states faces a critical gastroenterology workforce shortage with a projected deficit of 1,630…
Active Project Grant Awarded Last action
- Award ID
- R44EB034611
- Recipient
-
Elements Endoscopy Inc. UEI JGPEKMDYK9H3
- Awarding agency
-
National Institute of Biomedical Imaging and Bioenginering
National Institutes of Health, Department of Health and Human Services
- Obligated
- $1,435,234
Award facts
- Assistance listing
- 93.286 Discovery and Applied Research for Technological Innovations to Improve Human Health
- Completion date 65% complete
- Place of performance
- Minneapolis, MN 55410, USA
Award details come from USAspending.gov.
Description
Development of a modular, drive-by-wire, haptic controlled, reusable colonoscope system - the united states faces a critical gastroenterology workforce shortage with a projected deficit of 1,630 gastroenterologists in 2025, while an additional 19 million patients enter the screening pool. Current colonoscope design, unchanged since the 1980S, creates significant barriers: 67.9% of endoscopists suffer injuries, technical competence requires 200-400 procedures, and device degradation necessitates expensive repairs averaging $5,833 per incident. Traditional mechanical cable-actuated systems create inherent limitations that cannot be addressed through incremental improvements. Elements endoscopy has developed a novel drive-by-wire colonoscope that replaces mechanical cable- actuated systems with electronic control interfaces and drives, enabling modular design and consistent performance. Our NIH sbir phase i successfully delivered a complete functional prototype, validating electromechanical/hydraulic actuation, haptic feedback controls, and modular architecture. The phase II objective is to develop a commercially-ready drive-by-wire colonoscope system through four aims: (1) build the final electromechanical/hydraulically-based tip deflection subsystem with >200-cycle functional lifetime, (2) build the refined ergonomic handle optimized for diverse hand sizes with >20,000- cycle durability, (3) build separable connections with IP68-sealed hydraulic interfaces and validated disinfection efficacy, and (4) build the full modular system and assess performance with gastroenterologists using standardized protocols. The research employs systematic engineering development with comprehensive testing protocols ensuring force accuracy ±0.05N, motion resolution ±0.5MM, and performance within 5% of olympus PCF-H190D specifications. Clinician assessments will span 5TH-95TH percentile hand sizes to validate ergonomic improvements and user acceptance >80%. This technology represents the first successful implementation of drive-by-wire architecture in flexible endoscopy, establishing a new paradigm for medical device control systems. The expected outcomes include a design-frozen system ready for FDA 510(k) preparation. The system is intended to achieve equivalent per-procedure costs without incurring a maintenance burden. Additionally, IT is intended to maintain consistent performance throughout its device lifecycle and provide physician-specific ergonomic customization. The modular architecture and comprehensive data collection capabilities will reduce physician injuries, accelerate learning curves, and enable future AI-driven procedural assistance to address critical healthcare capacity constraints and improve patient outcomes through enhanced colonoscopy accessibility and quality.
Quick answers
Who received award R44EB034611?
R44EB034611 was awarded to Elements Endoscopy Inc. by National Institute of Biomedical Imaging and Bioenginering (National Institutes of Health) on May 1, 2023.
How much is award R44EB034611 worth?
$1,435,234 has been obligated on R44EB034611.