HVAC Controls Service Includes Maintenance and Repair of the Building Automation Control System.
BACKGROUND The facility currently has a BAC which operated 80 air handlers, 2500 VAV or other room temperature control devices, 9 chillers, 8 cooling towers 35 Direct Expansion (DX) units and 30 pumps. Routine and emergency maintenance is required for the BAC to operate efficiently and reliably. The BAC controls the Heating Ventilation and Air-conditioning systems for the entire medical site. The controls system is complex and has over 1,000 of control points, inputs, and outputs with in the medical facility. Sensor and calibration failures and automation controls require frequent maintenance. The HVAC systems will not run efficiently or fail completely without proper controls maintenance. A failure will create an unhealth environment for patient care. Contractor shall furnish all necessary travel, labor, materials, tools, documentation, parts, equipment, quality control, and supervision necessary for the inspection, (7 days per week, 24 hours per day) support of the equipment, software, and accessories (listed in the Schedule of Equipment) required for 1(one) Service Technician mandatory on-site, 2 (two) days per week (Tuesdays and Thursdays), for 2 (two) full 8 (eight) hour days, to provide maintenance, support, troubleshooting, programming, replacement parts and service of the existing (BAS), network, controls and software which include: 1. Siemens Talon Control System 2. Siemens Talon/ Niagara Front End 3. Siemens Talon Network Managers 4. Siemens Talon BACnet Controllers 5. Siemens Talon Field Devices (stats, variable speed drives, actuators, dampers, valves) 6. Johnson Controls Inc. (JCI) 7. Network Manager Controllers 8. JCI BACnet Controllers 9. JCI Field Devices (stats, controllers, variable speed drives, actuators, dampers, valves) 10. JCI Pneumatic Controllers included 11. JCI Legacy products and software (PMI NCM) 12. Distech BACnet Controllers & Associated field devices (stats, controllers, variable speed drives, actuators, dampers, valves) 13. Schneider BACnet Controllers & Associated field devices (stats controllers, variable speed drives, actuators, dampers, valves) 14. Tridium Niagara BAS front end controls. Each respondent must have an established business, with a local office and a full-time staff within 60 miles of site. Respondent shall have the following minimum number of service technicians employed by the local office: 3 Chiller Technicians, 3 General Mechanical Technicians, 3 Controls Technicians The Contractor shall have tee (3) years of successful experience in fully maintaining the full schedule of equipment for this contract. This staff must include a minimum of tee (3) "fully qualified" FSEs, who shall serve as the primary technician and back up for the servicing of the items listed on the schedule of equipment. "Fully Qualified" is based upon training and on experience in the field. For training, the FSEs must have successfully completed a formalized Tridium Niagara training program and received certification from the Siemens Talon Headquarters or a third party with equal training certification program for Tridium Niagara products. The FSEs must have a minimum of tee (3) years performing preventative maintenance and equipment repairs on Siemens Talon Building Technologies or Tridium Niagara products. The FSEs must have the ability to program in METASYS, Johnson Controls, Siemens, Distech, & Snyder controls with Niagara front end graphics. The FSEs must have the ability to troubleshoot components, network and diagnose programming issues. The Contractor shall provide written assurance of the competency of their personnel and a list of credentials of approved FSEs. The COR may authenticate the training requirements, request training certificates or credentials from the Contractor at any time for any personnel. The Government reserves the right to reject any of the Contractor's personnel and refuse them permission to work on VAMC equipment. The Contractor shall have at least two (2) qualified technician(s) capable of servicing the full schedule of equipment for this contract. The contract includes 2 (two) full 8 (eight) hour days during the week, on-call during afterhours and holidays with an escalation process if further assistance is needed. The VA is contemplating a base year with 1 option year. Services will begin on October 1, 2018. The anticipated contract type will be a firm fixed-price. The solicitation will be posted to FedBizOpp websites on or about August 17, 2018. This date is subject to change. A Site Visit is tentatively scheduled for August 23, 2018 at the Memphis VAMC campus. This date is subject to change. All contractors must be registered in the System for Award Management database (www.SAM.gov) when proposals are received and for the awardee at time of award to be eligible for award of a contract. All contractors must have an active Vendor Information Pages account (https://www.vip.vetbiz.gov/) reflecting they are currently registered as an SDVOSB. No further information will be provided prior to posting of the RFQ. The point of contact for this pre-solicitation notice is David Milner, Contract Specialist, at david.milner@va.gov. 36C24918Q9602 Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9
Solicitation 1/2 8/14/18, 3:49 PM