Update #4 · Latest ·
***** Amendment 0002 *****
The purpose of this amendment does the following:
- Extends the response date to September 10, 2019
- Revises the instructions and evaluations directions to allow for quotes that do not include all pumps.
- States the Government's willingness to make multiple awards, in the event that it is in the Government's best interest to do so..
Update #3 ·
The purpose of this amendment is to answer question (s) and provide more information. All other terms remain unchanged.
Questions and Request for more information:
1. Please provide the specific CTI/Brooks part# for the cryo pumps that you would like quoted. CTI/Brooks offer each one of their pump models in a variety of configurations so in order to quote the proper pump the manufacture's part# is necessary. Models identified in the solicitation that this pertains to include
a. CTI 10F
b. CTI 8
c. CTI 16
d. CTI 18F
2. The Edwards XDS5, XDS10, and XDS15 pumps have all been discontinued. These pumps have been replaced with the improved nXDS model pumps. Do you prefer to have the current nXDS model pumps quoted or are refurbished XDS pumps preferred?
Answer/Response:
1. See response below:
a. CTI 10F: p/n 8018338G001
b. CTI 8: p/n 8033083
c. CTI 16: p/n 8050056
d. CTI 8F: p/n 8107810G001
2. If a new replacement and original refurbished are available, please provide pricing for both.
.
Update #2 ·
The purpose of this amendment is to answer question (s) and provide more information. All other terms remain unchanged.
Questions and Request for more information:
1. Please provide the specific CTI/Brooks part# for the cryo pumps that you would like quoted. CTI/Brooks offer each one of their pump models in a variety of configurations so in order to quote the proper pump the manufacture's part# is necessary. Models identified in the solicitation that this pertains to include
a. CTI 10F
b. CTI 8
c. CTI 16
d. CTI 18F
2. The Edwards XDS5, XDS10, and XDS15 pumps have all been discontinued. These pumps have been replaced with the improved nXDS model pumps. Do you prefer to have the current nXDS model pumps quoted or are refurbished XDS pumps preferred?
Answer/Response:
1. See response below:
a. CTI 10F: p/n 8018338G001
b. CTI 8: p/n 8033083
c. CTI 16: p/n 8050056
d. CTI 18F: p/n 8107810G001
2. If a new replacement and original refurbished are available, please provide pricing for both.
.
Update #1 ·
Please see the following attachments for more details on this solicitatation:
Combined Synopsis/Solicitation document: This document gives full details on the requirement and all associated terms and conditions.
Attachment 1 - Pump Price List: This document provides a space for submitting pricing on the base requirement pumps and the pumps expected in Option 1, to be exercised within twelve (12) months after date of award..
Attachments
| File | Type | Posted |
|---|---|---|
| RFQ_-_Amendment_0002.docx | DOCX document | |
| Attachment_1_-_Pump_Price_List.xlsx | XLSX spreadsheet | |
| RFQ_Draft.docx | DOCX document |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity