MagPro X100 system
Closed Solicitation Posted
- Solicitation number
- 36C25719Q1017
- Agency
- Veterans Integrated Service Network 17 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 339112 Surgical and Medical Instrument Manufacturing
- PSC
- Not on record
- Place of performance
- COE for Research 4800 Memorial Dr. (151C) Waco, TX 76711 USA
Notice details come from SAM.gov. Updated .
Notice text
ITEM NUMBER
DESCRIPTION OF SUPPLIES/SERVICES
QUANTITY
UNIT
UNIT PRICE
AMOUNT
0001
1.00
LT
$00.00
$00.00
MagPro X100 Magnetic Stimulator 230V Systems
LOCAL STOCK NUMBER: 9016E0711
0002
1.00
BD
$00.00
$00.00
On-site installation and training included in pricing. Extended Warranty Platinum LOCAL STOCK NUMBER: PW
0003
1.00
LT
$00.00
$00.00
Shipping and insurance
GRAND TOTAL
$00.00
The Department of Veterans Affairs is seeking both manufacturers and/or distributors of the exact match or functionally equivalent equipment/ services to the following listed above.
Statement of Salient Characteristics MagPro X100 TMS Research System
The VA requires a repetitive TMS system that meets the requirements as defined below. The vendor shall provide all products and services necessary to complete the tasks outlined. The vendor shall perform all activities to assemble the system equipment to ensure a fully functional system, to include any support systems as applicable. Two rTMS stimulator systems shall be capable of stimulating at a maximum strength of no less than 32 kT/s near the coil surface. The systems must have a documented lineage of substantial equivalence to the medical device with 510(k) number K061053. Biphasic pulse width shall be no more than 290 microseconds. Each stimulator shall have an active cooling system such as water cooling or refrigeration making it capable of delivering no less than 20,000 pulses before warm-up at ambient temperature (20 degrees Celsius), when running a protocol with pulses at full dB/dt, pulse trains at 10Hz, 40 pulses per train, 26-second inter-train interval. A system for head fixation shall ensure that coil placement relative to head position remains constant throughout a treatment session this system should provide adequate resistance to prevent head motion on the millimeter scale, rather than merely providing sensory feedback when such motion occurs. An example of an inadequate head fixation system would be stringing adhesive tape across the patient s forehead. An internal tracking system shall notify the user of coil use over time, and a replacement plan shall cover the cost of replacement coils including shipping after coils have reached their expected end of reliable stimulation. Both systems shall be capable of neuronavigational, providing native support for DICOM and NifTI file formats. Neuron avigation software shall support the visualization of previously recorded functional MRI data in real time. Both systems shall be capable of delivering sham treatment in the form of electrical stimulation to the skin synchronous with the sound of magnetic pulses in placebo-controlled trials, and these electrodes shall emanate from the stimulator coil itself, while no magnetic fields are permitted to stimulate CNS nerve cells in the sham condition. One system shall include a robotic coil placement apparatus which, in conjunction with the included neuronavigational system, allows for the automatic placement of the coil in user-defined locations in a corresponding 3-dimensional model of the patient s scalp based on previously acquired MRI data. This robotic system shall include a sensor that prevents the transmission of force more than ten Newtons to the patient s scalp at any time.
Part # Qty
9016E0711 2 MagPro® X100 Magnetic Stimulator, 230V
9016D0031 2 Isolation Transformer rTMS System
9016B0383 2 Trolley for MagPro (includes coil holder accessories)
9016E0482 2 Coil C-B60 - flat figure of eight coil with built-in power control
9016E0151 1 Coil Cool B65CO - (Axilum TMS-Cobot Edition of the active cooled coil)
9016E0161 1 Coil Cool B65 A/P CO (Axilum TMS-Cobot Edition of the active/sham coil)
9016E0491 1 Coil Cool B65 - dynamic cooled butterfly coil
9016E0501 1 Coil Cool B65 A/P combined active & sham coil
9016S0161 2 Research Software for MagPro R30 / X100 for double blind studies - USB less
9016B0151 2 Coil Cooler for Cool Coils
9016B0171 2 Super Flex Arm for Coil Positioning - long
9016B0081 2 Motorized Procedure Chair with neck rest and cloth cover
9016B0252 2 Head Stabilizer System (Special Vacuum Pillow and Evacuation Pump)
9016B0601 2 Textile Caps - XSmall, Small, Medium, Large, Extra Large-10 pcs.each bundle
Sub-Total for two MagPro systems (1)
7611L1710 2 LocaliteTMS Navigator for Research-Spectra (MRI Based Neuro Navigation System)
Includes, NDI Polaris Spectra (large format) Infrared Tracking camera, Camera stand,
Instruments: Registration Pointer, Calibration Plate, Adhesive Head Reference,
2 Coil Geometry Trackers with MagVenture coil ring brackets to fit the incl. coil handles
Localite TMS Navigator software with remote control for MagPro stimulator, High perf.
PC with large format monitor (24"), Three function footswitch, trigger box, and all
functional data overlay capabilities (MR- based, MR-Less, MEP+Brainmapping, fMRI, EEG)
Sub-Total for two Localite systems (2)
9016ECOB01 1 Axilum Robotics TMS-Cobot TS MV (1)
Configuration includes:
Axilum Robotics Optical tracking system for TMS-Cobot TS MV (1) (2)
TMS-Cobot Coil adaptation kit for MagVenture Cool B65 CO coil (3)
TMS-Cobot Coil adaptation kit for MagVenture Cool B65A/P CO coil (3)
Training Onsite installation and training Included.
Attachments
| File | Type | Posted |
|---|---|---|
| 36C25719Q1017-001.docx | DOCX document | |
| 36C25719Q1017-000.docx | DOCX document |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity