J045--High & Low Pressure Boiler Maintenance & Safety Device Testing

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C24225Q0983
Agency
Veterans Integrated Service Network 2 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
J045 Maint/Repair/Rebuild Of Equipment- Plumbing, Heating, And Waste Disposal Equipment
Place of performance
Hudson Valley Healthcare System Montrose and Castle Point Campuses. Montrose, New York 10548, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2 is seeking contractors to provide comprehensive maintenance and safety device testing services for high- and low-pressure boilers at the Hudson Valley Healthcare System's Castle Point and Montrose campuses. The contract requires vendors to perform preventive maintenance, corrective maintenance, repairs, safety device testing, tuning, and calibration services for government-owned boilers ranging from 200 to 1000 horsepower that operate on natural gas and #2 fuel oil. Contractors must provide all labor, materials, equipment, supervision, and specialized services including R-stamp welders, boiler technicians, and controls engineers, while adhering to VA Directive 1810, VHA Boiler Plant Safety Device Testing Manual 8th edition, NFPA 85A standards, and manufacturer requirements. The work must be conducted under COR supervision with detailed reporting requirements within seven business days of each inspection. The pre-solicitation notice was posted on August 15, 2025, with the formal solicitation scheduled for release on August 20, 2025, and responses due by August 29, 2025, at 10:00 AM Eastern Time.

This opportunity is designated as a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) and will be awarded as a Firm Fixed-Price contract under NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors). The contract structure includes a base performance period of one year with four optional extension years, potentially providing up to five years of continuous service. Key performance requirements include semi-annual and annual safety device testing intervals, 24/7 emergency service support with 4-hour acknowledgment and 8-hour on-site response times, and the installation of new oxygen analyzers, probes, and safety relief valves during the base year. Qualified technicians must possess at least one year of trade school education and five years of relevant experience. The solicitation number is 36C24225Q0983, and interested parties may express interest by contacting Contracting Officer Natalie Acevedo, though responses to this pre-solicitation notice are not mandatory.

Notice text

Description:

The Department of Veterans Affairs (VA) intends to issue a solicitation for the maintenance and safety device testing of high- and low-pressure boilers located at various Hudson Valley VA facilities. The contractor shall provide all labor, materials, equipment, tools, supervision, and transportation necessary to perform preventive maintenance, corrective maintenance, repairs and safety device testing services for boilers in accordance with VA standards and regulatory requirements.

Scope of Work:

1. GENERAL REQUIREMENTS:

a. The vendor shall provide all labor, management, tools, supplies, and equipment to provide routine and emergency repair service, boiler safety device testing, tuning, and calibration for Government owned boilers and associated equipment in accordance with this contract. The vendor shall have the ability to provide or procure specialty services such as R-stamp welders, Boiler technicians, controls technicians, controls engineers as needed.

b. Vendor shall remove from service one boiler at a time for the boiler tests, tuning and calibration procedures. Work must be conducted when the COR or his/her designate is available on site to monitor the work.

c. Boiler Plant Preventive Maintenance shall be in accordance with Veterans Affairs (VA) Directive 1810dated January 4, 2023, VHA Boiler Plant Safety Device Testing Manual 8th edition (or current edition), NFPA 85A, Boiler and Burner manufacturers requirements, industry standards and statutory requirements.

d. The vendor while performing preventive maintenance, safety device testing, tuning and calibration shall inform the COR of any required repairs, equipment malfunction and/ or abnormalities

2. HIGH PRESSURE (HP) BOILER PLANT SAFETY DEVICE TESTING REQUIREMENTS:

a. The vendor shall perform the below safety device testing in accordance with VHA Directive 1810 & VHA Boiler Plant Safety Device Testing Manual 8th edition (or current edition). All safety device test results and data shall be recorded and submitted in the VHA Boiler Plant Safety Device Testing Manual current edition, see reporting requirements for additional information. The safety device tests shall be performed at the frequencies indicated in the SOW, where (6M) indicates tests that shall be performed every six

months (for our campus, that is typically August and February), and (Y) indicates tests that shall be performed annually.

Set-Aside Status: This procurement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs), therefore Limitations on Sub-Contracting applies

Anticipated Solicitation Release Date: 8/20/2025.

Contract Type: Firm Fixed-Price

NAICS Code: 238220 - Plumbing, Heating, and Air-Conditioning Contractors

Point of Contact: Natalie Acevedo, Contracting Officer, Natalie.Acevedo@va.gov, 718-584-9000 x 2105 / 6732

Response Requirements: Interested parties should express their interest by sending an email to the point of contact listed above. Questions regarding the upcoming solicitation are to be submitted in writing via email. Responses to the pre-solicitation notice are not mandatory but will assist the VA in determining the level of competition and interest within the industry.

Closing Comments: This pre-solicitation notice does not constitute a request for quotes (RFQ) and is not a guarantee that an RFW will follow. It is for informational purposes only and to give potential offerors an opportunity to express interest and to prepare to respond to the formal solicitation when it is released.

Attachments

Files attached to this notice, newest first
File Type Posted
SOW.pdf PDF
36C24225Q0983.docx DOCX document

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
J045--High & Low Pressure Boiler Maintenance & Safety Device Testing Award Award Notice
J045--High & Low Pressure Boiler Maintenance & Safety Device Testing Latest solicitation Solicitation
J045--High & Low Pressure Boiler Maintenance & Safety Device Testing This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity