About this opportunity

This Limited/Sole Source Justification Notice from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19 was for renovating space at the Oklahoma City VA Medical Center to create negative pressure isolation wards for the medical and surgical intensive care units on the 5th floor for treatment of COVID-19 patients. Due to the emergency need to prepare for COVID-19 with an estimated start date of April 21, 2020, the agency conducted limited market research and determined Jackson Mechanical was the only contractor able to start immediately with their existing knowledge of and previous work at the facility. The Department of Veterans Affairs awarded contract 36C25920C0106 for these renovation services in an unknown amount to an unknown vendor on April 21, 2020, with an estimated value of $439,598 to create 1 Ante Room, modify supply ducts, close return air ducts, modify outside air systems, and install two negative air pressure machines to generate 4,500 CFM of pressure across the ICU areas.

Notice text

Creating an AII negative pressure isolation ward for the MICU of the 5th floor. This would include building 1 Ante Room for entire space, moving supply duct into space to create positive pressure. The contractor would then need to close of all return air duct to space, modify the existing outside air to help balance the system. Finally, the contractor would need two negative air pressure machines’ creating 4500cfm of negative pressure, exhausted out window in northwest hallway. After completing the MICU we would then create an AII negative pressure isolation ward for the SICU of the 5th floor

Awarded contract 36C25920C0106 to unknown vendor for unknown amount on 2020-04-21.