HVAC Replacement Myrtle Beach

Closed Pre-Solicitation Posted

Solicitation number
697DCK23R00192
Agency
Southwestern Region Federal Aviation Administration, Department of Transportation
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
Not on record
Place of performance
Myrtle Beach, South Carolina 29572, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice seeks to replace two roof-top air conditioning units at the Myrtle Beach Air Traffic Control Tower for the Department of Transportation Federal Aviation Administration Southwestern Region. Bidders must provide all labor, materials, equipment, supervision, demolition, and installation for replacing the RTUs in three phases, along with associated electrical upgrades and roof repairs. Proposals are required to address each individual phase and the total project cost, and must comply with all FAA standards. The deadline for proposals is February 15, 2023, with evaluation based on technical qualifications, past performance, and price.

There is no set-aside designated for this procurement. The primary NAICS code is 238220 - Plumbing, Heating, and Air-Conditioning Contractors, with the predominant PSC code R499 - Other ADP and Telecommunications Services. The statement of work provides specifications for replacing one 20-ton and one 17.5-ton RTU, along with other minor HVAC components. Proposers are advised to coordinate construction activities closely with airport operations to minimize disruptions.

Notice text

2 versions

Update #2 · Latest ·

This is a SOURCES SOUGHT only for market research.

Provide all labor, tools, equipment, materials, clean up, and supervision required for replacing two (2) roof-top air conditioning units (RTUs), serving the tower base building; to include but not limited to: providing and installing two (2) 2-ton mini-splits for Equipment Room; providing and installing one (1) new 2-ton ducted mini-split for TRACON; demolition of old 20-ton RTUs and providing and installing new 17.5-ton units in place on existing adapter curbs; re-establishing new control interface with existing BARD MC-3000 controller; new electrical power feeds with NEMA-4 disconnects; associated roofing repair and restoration as needed; selective salvage and re-installation of the existing lightning protection; providing and installing new transient voltage surge suppression systems. 

Update #1 ·

Provide all labor, tools, equipment, materials, clean up, and supervision required for replacing two (2) roof-top air conditioning units (RTUs), serving the tower base building; to include but not limited to: providing and installing two (2) 2-ton mini-splits for Equipment Room; providing and installing one (1) new 2-ton ducted mini-split for TRACON; demolition of old 20-ton RTUs and providing and installing new 17.5-ton units in place on existing adapter curbs; re-establishing new control interface with existing BARD MC-3000 controller; new electrical power feeds with NEMA-4 disconnects; associated roofing repair and restoration as needed; selective salvage and re-installation of the existing lightning protection; providing and installing new transient voltage surge suppression systems. 

Attachments

Files attached to this notice, newest first
File Type Posted
Statement of Work _ MYR RTU Replacement _ 12-15-22 draft.doc DOC document

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity