Hempro Vessel Harvest Probe

Awarded Award Notice Posted

Solicitation number
VA24117Q0057
Agency
Veterans Integrated Service Network 1 Veterans Health Administration, Department of Veterans Affairs
Awarded
to Trillamed LLC
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Contract number
VA24117P0291 Federal contract award
NAICS code
334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
PSC
Not on record

Notice details come from SAM.gov. Updated .

Notice text

Added: Nov 15, 2016 1:59 pm This requirement consists of 1 line item:



VH-4000 Hempro 2



The following salient characteristics are detailed description of the requirements for this solicitation:

VASOVIEW HEMOPRO 2

Brand Name Specific: VASOVIEW HEMOPRO 2

VASOVIEW HEMOPRO 2 is the latest generation of VASOVIEW simultaneous cut-and-seal technology for Endoscopic Vessel Harvesting (EVH). An embodiment of the Maquet commitment to highly refined technology and robust design, VASOVIEW HEMOPRO 2 virtually eliminates thermal spread and helps harvesters safely acquire high-quality conduits for coronary artery bypass graft (CABG) surgery.* The VASOVIEW HEMOPRO 2 Endoscopic Vessel Harvesting (EVH) System offers the highest level of design innovation and ergonomic sophistication. It represents the gold standard in vessel harvesting for both the saphenous vein and radial artery delivering superb visualization and exceptional maneuverability to enable harvesters to work more efficiently and effectively for improved patient outcomes. VASOVIEW HEMOPRO 2 now also comes packaged with the VASOSHIELD Pressure Controlling Syringe inside as a convenience to users taking every advantage of tools that help maximize conduit quality. The VASOSHIELD Pressure Controlling Syringe is a device that protects vessels from over distension and potential endothelial injury. Vessels flushed at controlled, lower pressures also have been shown to more effectively overcome spasm and maintain their endothelial and medial layers.

The insulated Jaws are a key feature of the VASOVIEW HEMOPRO 2 System, providing maximum protection for the saphenous vein or radial artery. A new spot cautery feature allows harvesters to respond quickly and easily to maintain clear working tunnels and to ensure hemostasis.

Easy-to-learn techniques enable harvesters to position the Jaws while protecting the main conduit.*

Enhanced cutting capability for easier fasciotomy

Advanced system design helps to enhance the efficiency and safety of vessel harvest

The new, more natural grip handle is comfortable to hold and features an easy-activation toggle. Harvesters have a simple, smooth, and highly responsive one-fingertip control.

Qty. 200 Each

Attachments

Files attached to this notice, newest first
File Type Posted
VA241-17-Q-0057-003.docx DOCX document
VA241-17-Q-0057-004.pdf PDF
VA241-17-Q-0057-002.docx DOCX document

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity