Hazardous Waste Accumulation Point - Amendment 01

Closed Solicitation Posted

Solicitation number
FA5606-20-Q-2034
Agency
Air Forces Europe and Africa Air Force, Department of Defense
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
493110 General Warehousing and Storage
PSC
5410 Prefabricated And Portable Buildings
Place of performance
Spangdahlem 54529 DEU

Notice details come from SAM.gov. Updated .

Notice text

The contractor shall provide all services and supplies necessary to deliver or construct a hazardous waste accumulation point to the following specifications.


- Walk-in secure storage facility--9 meters or 30 feet long by 2.5 meters or 8 feet tall by 2 meters or 6.5 feet wide. Rated safe for water polluting substances as well as flammable, toxic and oxidizing material. Roof and walls, double wall insulated side walls and floors made of fire-resistant materials. Must Meet NFPA standard for UD Class 1 and Combustible Class IIIA Indoor or outdoor installation options on existing concrete surface. Heat detector must be mounted on the inside ceiling or at waist level on the inside wall.
- Ventilation system to avoid over-saturation of toxic air fumes. Ventilation system must be able to move 500 meters of air per hour.
Control panel for temperature setting ajustment. There must be a temperature sensor inside and out that governs the ventilation
system. Ventilation must port to the outside, no recirculating system. Fresh air must be drawn in and contaminated air must be vented
out. Air ports must have fire and weather protection covers.
- LED Interior and Exterior Lighting, resistant to potential fume ignitions, with intrinsically safe light switches on the inside and outside of the container.
- Lockable Double Doors in the Center of the container 2 meters or 6.5 foot wide by 2.5 meters or 8 feet tall. Must have open door
attachments that hold doors open when in use by personnel.
- Attached Ramp leading into the container. Non-Skid surface finishing or coating required.
- Container must be light color paint to repel heat, no dark colors. Hazardous Waste Accumulation Storage Area Placards affixed to front door.
- Grounding cables must be attached and grounding rods provided.
- Entire floor must have at least a half meter clearing from container bottom to the attachment of a grating system that will contain any potential spills. Must be able to contain 200 gallon spill indefinitely. The grating mesh openings cannot be larger than 1 inch by 1 inch.

Attachments

Files attached to this notice, newest first
File Type Posted
Questions and Answers V2.pdf PDF
FA5606-20-Q-2034 Extended.pdf PDF
Questions and Answers.pdf PDF
Sample HWAP 2.png PNG image
Sample HWAP 1.png PNG image
FA5606-20-Q-2034 Finale.pdf PDF