Billings fire station water heater replacement

Closed Pre-Solicitation Posted

A newer solicitation was posted. See the latest solicitation from .

Solicitation number
140L3623Q0004
Agency
Bureau of Land Management Department of the Interior
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
N045 Installation Of Equipment- Plumbing, Heating, And Waste Disposal Equipment

Notice details come from SAM.gov. Updated .

Notice text

This is a sources-sought notice / request for information (RFI) only. This is not a request for a quote or proposal. This RFI is issued solely for market research purposes and does not constitute a solicitation. The Government will not reimburse the costs of preparing responses to this RFI. The Government reserves the right to use any information provided by respondents for any purpose deemed necessary to create the resultant solicitation. This RFI is issued by the Bureau of Land Management, Montana/Dakotas State Office, for the purpose of performing market research to determine the availability, interest, and capability of small businesses under NAICS Code 238220.

I. Project Description

A. Project Purpose: The existing domestic water heater at the Billings Fire Station has failed and repair parts are unavailable.

B. Project Work Elements: The work of this project consists of:

1. Replacement of the existing domestic water heater, including demolition of the existing domestic water heater; installation of a new high-efficiency water heater; reconfiguring the existing domestic water heating system piping; and reconfiguring the existing water heater vent piping.

2. Any and all electrical work required for related work elements above.

3. Demonstration and training for BLM site personnel.

II. Project Location

A. The Billings Fire Station is located at 1299 Rimtop Drive, Billings, Montana 59105 (LAT 45.805900, LONG -108.521739). A pre-bid site inspection by potential bidders to verify existing conditions at the project site is highly recommended, but not mandatory.

III. Water Heater Information

Water heater shall be modulating-condensing type suitable for firing with natural gas at high altitude, shall be rated for 160 psig working pressure, and shall be 95 percent thermally efficient, with 100 gallon glass-lined insulated tank, sea level input capacity of 150,000 BTU/hr, and 120VAC, 5A electrical characteristics. Provide the water heater with ASME temperature and pressure relief valve, condensate neutralizer kit (Part No. 100289339), seismic water heater restraint kit (Holdrite QS-120, or approved equal), and grounded power cord with plug. The water heater shall be installed in accordance with the manufacturer¿s installation instructions and shall be adjusted for proper operation at 3,100¿ elevation. A.O. Smith BTH-150, by A.O. Smith Corporation, Ashland City, Tennessee 37015, or approved equal. The new water heater shall be installed on the existing concrete equipment pad and shall be anchored to the wall behind the water heater with seismic restraint straps.

Submission requirements:
Potential sources are invited to submit a Capabilities Statement describing the requests stated above. All responses should be submitted via e-mail to jalvarez@blm.gov no later than (1:00pm) (MST) on (29 December 2022).

Only attach MS Word/Excel compatible files or Adobe Acrobat PDF files in electronic correspondence. Telephone inquiries will not be considered.

Please provide the following information:
1. Company name and address
2. Company Point of Contact, phone number, and email
3. CAGE Code Number and Unique Entity ID (SAM) number
4. Socio-economic categories associated with the company (i.e., SDB, WOSB, VOSB, etc.)
5. Identify if your company has any current GWACs i.e. GSA schedules, NITAAC, SEWP, etc.
6. Capabilities Statement
7. After reviewing the SOW:
a. Provide the biggest issues you foresee during the performance of this project.
b. Errors that need corrections before solicitation.
c. Estimated lead times
d. Any other concerns.

Attachments

Files attached to this notice, newest first
File Type Posted
Billings_FS_Water_Heater_Replacement_Scope_of_Work_1.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Billings fire station water heater replacement Latest solicitation Solicitation
Billings fire station water heater replacement This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity