6515--PHILIPS DigitalDiagnost SKYPLATE
Closed Pre-Solicitation Posted
A newer solicitation was posted. See the latest solicitation from .
- Solicitation number
- 36C24624Q0600
- Agency
- Veterans Integrated Service Network 6 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 334517 Irradiation Apparatus Manufacturing
- Place of performance
- Department of Veterans Affairs Richmond VA Medical Center Richmond, Virginia 23249, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs (VA) is seeking to procure a PHILIPS SKYPLATE GRID wireless portable grid plate accessory to upgrade their current Philips DD X-ray system at the Richmond VA Medical Center. The key requirements include compatibility with Philips DD 2.x, 3.x, 4.x and 5.x systems, providing optimal image quality while reducing radiation dose and scatter, with rechargeable batteries and a lightweight, compact design. The solicitation is an open market Request for Quotations (RFQ) with a response due date of March 27, 2024 at 1:00 PM EST. The contract will be awarded to the responsible offeror with the lowest acceptable price.
This is a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside procurement with a North American Industry Classification System (NAICS) code of 334517. The estimated value of the contract is not provided. There are no incumbent contractors identified in the notice. The quantity required is one unit of the PHILIPS SKYPLATE GRID, with additional items such as the DigitalDiagnost 4.x / C90 Upgrades and SkyPlate Infrastructure Kit also included in the solicitation.
Notice text
This solicitation is a request for quotations (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2023-01.
This solicitation is issued as an Open Market, Service Disable Veteran Owned Small Business (SDVOSB) SET_ASIDE. The associated North American Industrial Classification System (NAICS) code for this procurement is 334517, with a small business size standard of 1000 Employees.
The Richmond VA Medical Center, located at 1201 Broad Rock Blvd, Richmond, VA 23249 has requested to purchase a Brand Name Only PHILIPS SKYPLATE GRID direct replacement part to upgrade their current Philips DD X-ray system SKYPLATE GRID.
This is a Brand Name Only Requirement.
Salient Characteristics
Functions to be performed.
Wireless portable Grid plate accessory for the Philips DD 2.x and 3.x EZD, EZDFR 4.x and 5.x. Utilized for Diagnostic imaging of Veterans
Will provide Axillary view of shoulder per radiologist and orthopedics
Suitable for difficult projections or anatomy such as shoulder. Skull, c-spine views, and patella views of the knee
Performance required.
Must be able to do multiple positioning for lateral or oblique projections without having to move patient.
Must provide optimal image quality while keeping radiation dose low, reducing radiation scatter, and improving image contrast.
Wireless transmission of image data to Philips DD 2.x and 3.x EZD, EZDFR 4.x and 5.x.
Must have rechargeable batteries capable of powering unit for standard imaging examinations.
Essential physical characteristics; Dimensions (if applicable)
Must be compatible to fit current X-ray rooms Philips DD 2.x and 3.x EZD, EZDFR 4.x and 5.x.
Software that connects grid to Philips DD 2.x and 3.x EZD, EZDFR 4.x and 5.x. unit and other compatible units, to use the detector on current diagnostic x-ray rooms
Must dust proof and able to be cleaned with liquid-based solutions.
Must be light weight (maximum of three pounds) for everyday clinical use and reduce user fatigue.
Must be 1 depth as to not interfere with critical equipment, cable, tubes, and catheters.
Easily change out batteries without needing special tools to maintain proper workflow.
Grid size must be 10 x 12
ITEM
NUMBER
DESCRIPTION OF
SUPPLIES/SERVICES QUANTITY UNIT
UNIT
PRICE
AMOUNT
0001
1.00 EA
DigitalDiagnost 4.x / C90 Upgrades 712084 LOCAL STOCK NUMBER: 712084
0002
1.00 EA
SkyPlate Infrastructure Kit NRDN215 LOCAL STOCK NUMBER: NRDN215
0003
1.00 EA
Upgrade SkyPlate Set Small NRDN218 LOCAL STOCK NUMBER: NRDN218
0004
1.00 EA
Grid Portrait SkyPlate Small NRDN404 LOCAL STOCK NUMBER: NRDN404
The vendor shall be an OEM, authorized dealer, authorized distributor, or authorized reseller for the proposed medical supplies, medical equipment, and/or services contracts for maintenance of medical equipment (i.e. replacement parts), verified by an authorization letter or other documents from the OEM, such that the OEM s warranty and service are provided and maintained by the OEM. All software licensing, warranty and service associated with the medical supplies, medical equipment, and/or services contracts for maintenance of medical equipment shall be in accordance with the OEM terms and conditions.
The Government will award a contract resulting from this RFQ to the responsible offeror whose quote represents the lowest price acceptable for the government. Quotations shall be received no later than 1PM EST on March 27, 2024. Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f) and will not be evaluated. Quotations shall be submitted via email to Ronnie Gregory at Ronnie.Gregory@va.gov.
Attachments
| File | Type | Posted |
|---|---|---|
| 36C24624Q0600_1.docx | DOCX document |
Notice history