6515--NuTrace R+ Scanner
Closed Pre-Solicitation Posted
- Solicitation number
- 36C26025Q0226
- Agency
- Veterans Integrated Service Network 20 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 339113 Surgical Appliance and Supplies Manufacturing
- Place of performance
- Department of Veterans Affairs White City VA Medical Center White City, Oregon 97503, United States
- Points of contact
-
- Maureen Sundstrom maureen.sundstrom@va.gov (253) 888-4935
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration, specifically Veterans Integrated Service Network 20, is conducting a Sources Sought Notice for market research to identify potential vendors for medical scanning equipment at the White City VA Medical Center. The procurement involves 5 NuTrace R+ Scanners and 1 Ratero Cleaning Solution System, with specific technical requirements including the ability to read 2D Matrix codes as small as .010 x .010mm, operate with a laserless beam 2MP camera, and be compatible with Windows 10/11 operating systems. Potential vendors must be registered in the System for Award Management (SAM) and, if not manufacturers, must provide proof of authorized dealer status. The solicitation targets Service-Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), Small Business Manufacturers, and other qualifying small businesses under NAICS code 339113. Responses are due by February 3, 2025, at 10:00 AM PST, with submissions to be sent to Maureen.Sundstrom@va.gov.
The procurement is currently an unrestricted/open market opportunity with no specific set-aside designation, though preference will be given to small businesses and veteran-owned businesses. The intended contract will be a firm-fixed price supply purchase, with the SBA Non-Manufacturer Rule applicable and no waiver to be sought. Qualifying businesses must have no more than 800 employees to be considered a small business for this opportunity. The equipment must be new, with no used or refurbished items accepted, and vendors are required to provide a courtesy quote for price reasonableness evaluation. Delivery will be to the White City VA Medical Center Warehouse in Building #225A, located at 8495 Crater Lake Highway in White City, Oregon. While this is a market research notice and not a formal solicitation, it provides detailed salient characteristics for the required medical scanning equipment, including specific performance requirements such as rapid barcode reading, audible and LED notification of successful scans, and full compliance with FDA and CDC standards.
Notice text
Sources Sought Notice
Sources Sought Notice
*= Required Field
Sources Sought Notice
THIS IS A SOURCES SOUGHT NOTICE ONLY. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement, and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Small Business Manufacturers, and other Small Businesses, interested and capable of providing items requested, as well as any large business interested and capable. This REQUEST FOR INFORMATION/SOURCES SOUGHT NOTICE in support of the White City VA Medical Center, is for market research purposes and planning purposes only and is not to be construed as a commitment by the Government. The Government will not pay for information solicited. Respondents will not be notified of the results of the evaluation. Results will be used to determine set-aside.
The intended contract is a firm-fixed price supply purchase.
The SBA Non-Manufacturer Rule is applicable, and a waiver will not be sought for this potential acquisition.
Potential contractors shall provide, at a minimum, the following information:
1) Company name, address, and point of contact, phone number, e-mail address, and SAM.gov UEI number/code.
2) Anticipated North American Industry Classification System (NAICS) code is 339113. The largest a firm can be and still qualify as a small business for Federal Government programs is no more than 800 employees. Please indicate whether you are a Small Business, SDVOSB, VOSB, Small Business Manufacturer, Other Small Business, or Large Business, and whether you are the manufacturer of the items listed below.
3) The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought notice. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Notice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror to have completed their business Online Representations and Certifications Application in the System for Award Management (SAM).
4) Any Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be registered with the Small Business Administration VetCert Registry located at https://veterans.certify.sba.gov.
5) If not a manufacturer, only authorized representatives/providers/distributors of the manufacturer will be considered. Equipment must be new, no used or refurbished equipment accepted. Please provide a proof of authorized dealer or reseller letter from manufacturer.
6) If you are the manufacturer, do you have any designated or authorized distributors? If so, please provide their name, telephone, point of contact and size status (if available).
7) This is a brand name or equal requirement. As such, the salient characteristics reflect the physical, functional, or performance characteristics that equal products must meet to satisfy the Government s needs. To be considered for any potential solicitation, offers of equal products, including equal products of the brand name manufacturer, must:
(a) Meet the salient physical, functional, or performance characteristic of the brand name item and those specified in this sources sought; clearly identify the item by Brand name, if any and make/model number.
(b) Include descriptive literature such as illustrations, drawings, or a clear reference to descriptive data or information available that identifies that the equal item meets or exceeds the salient characteristics required by the Government.
(c) Identify the manufacturer name (OEM) and manufacturer part number, as well as any warranty information.
(d) Please provide a courtesy quote in response to this request to evaluate price reasonableness for any set-aside determination, and any applicable contract vehicle information.
It is the intent of the VA to use the information gathered for market research purposes only. If a formal solicitation is released, it will be posted via the Contracting Opportunities website located at beta.sam.gov. or GSA eBuy.
DESCRIPTION OF THE REQUIREMENT:
The Department of Veterans Affairs is looking to obtain information on vendors who can provide the products as outlined below. This is an Unrestricted/Open Market Brand Name or Equal To Request for Information/Sources Sought Notice.
Delivery:
White City VA Medical Center
Warehouse Bldg #225A
8495 Crater Lake Highway
White City, OR 97503
Items: Brand Name or Equal to of the following supplies
Item #
Description/Part Number*
Qty
Price
Extended Amount
1
NuTrace R+ Scanner
5
2
Ratero Cleaning Solution System: Includes
32 electrochemical, fabric tips and 32 zip tie holders
Ratero Solution 900ml bottle
Ratero electrical pen
1
Â
SUBTOTAL (Products)
Â
SALIENT CHARACTERISTICS
Must be able to read off bright, reflective, matte, and low contract surfaces
Must be powered by a laserless beam 2MP camera with LED lighting and a USB outlet supply from a computer is needed
Must be able to read 2D Matrix as small as .010 X .010mm (4 mils)
It must come with five 2D data matrix readers for code verification and use with Censitrac.
2D Scanner must be fast at reading barcodes, with no need to push a trigger to scan the barcodes
2D Scanner should read code in under 1 second irrelevant of instrument contrast, material, or position of the code
Must have on-board decoding audible notification and LED flash indicating successful read
Must be fully compliant with all applicable standards and regulations set forth by the FDA, CDC
Must have small footprint with stainless steel design for disinfection
Must have fully configurable export options Keyboard Wedge emulator, virtual COM
Must be able to operate on a Windows-based 10 and 11 operating software
Additional information sought:
Warranty Please describe the offered warranty.
Place of manufacture Please provide the place of manufacture.
If your business is interested and capable, please send the capability statement outlined above, and a courtesy market research quote to Maureen.Sundstrom@va.gov by 10:00 AM PST on February 3 30, 2025. NO PHONE CALLS, PLEASE.
Again, this is not a request for quote, and no solicitation is available at this time.
Attachments
| File | Type | Posted |
|---|---|---|
| 36C26025Q0226.docx | DOCX document |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity