Waco_2022.01 RFQ_Floorplan.pdf
PDF 335 KB Posted
- Attached to
- Office Furniture - New Office Federal contract opportunity
- Solicitation number
- Waco_2022_01
- Issued by
- Administrative Office of the U.S. Courts
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Waco.2022.01 RFQ_DeliveryTerms.pdf | ||
| WA.2022.001 Furniture_Location_List.pdf | ||
| Waco.2022.01 RFQ_GenProv.pdf | ||
| Waco.2022.001 RFQ_VendorInfoSheet.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES:
1. THESE DRAWINGS SHOW A GENERAL INTENT TO RECEIVE A QUALITY FINISHED
PRODUCT. CONTRACTOR SHALL BE RESPONSIBLE TO INCLUDE ALL ITEMS
REQUIRED TO COMPLETE THIS PROJECT IN A FINISHED MANNER, WHETHER
ALL CONDITIONS ARE SHOWN OR NOT.
2. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALE.
3. ALL INTERIOR DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED.
4. MAINTAIN 1'-6" CLEAR DIMENSION AT ALL DOORS AT LATCH SIDE WHERE
DOORS OPEN TOWARDS YOU. MAINTAIN 1'-0" CLEAR AT ALL DOORS THAT
HAVE BOTH A CLOSER AND A LATCH AT LATCH SIDE WHERE DOOR OPENS
AWAY FROM YOU.
5. ALL WALLS TO BE 3-1/2" WOOD STUD, UNLESS OTHERWISE NOTED.
6. TRANSITION STRIPS TO BE USED AT CHANGES IN FLOORING MATERIAL. REFER
TO ROOM FINISH NOTES.
7. ALL DOOR FRAMES TO BE LOCATED 4" FROM PERPENDICULAR WALL.
PLAN NORTH
TRUE NORTH
1 FLOOR PLAN - FIRST FLOOR
SCALE: 1/8" = 1'-0"
KEYED NOTES:
1. OPEN TO ABOVE.
2. ALIGN NEW ENCLOSURE WITH EXISTING FOR A CONSISTENT APPEARANCE.
3. OPEN TO BELOW.
4. REFRIGERATOR BY OWNER.
5. MILLWORK; RE: A7.2.
6. WALL TO BE COVERED IN 19MM (3/4") PLYWOOD IN 4FT X 8FT SHEETS;
BOTTOM OF BOARD TO BE MOUNTED 6" ABOVE FINISH FLOOR. PLYWOOD
SHALL BE A/C GRADE AND FINISHED WITH TWO COATS OF FIRE RETARDANT
PAINT. USE GALVANIZED, ZINC PLATED, OR STAINLESS STEEL HARDWARE WITH
A FLAT HEAD FASTENER. FINISHED INSTALLATION SHALL HAVE FLUSH
APPEARANCE WITH COUNTERSUNK SCREW HEADS.
KB MEASURE
540 USF
7' -1
11 4"
'-0
1 2"
UP
UP
UP
5,488
6,397
FEC
FE
WAITING AREA
100.A
CORR
100.B
OFFICE
OFFICE
OFFICE
OFFICE
WORK ROOM
OFFICE
OFFICE
OFFICE
OFFICE
BREAK ROOM
STAIR
100.C
100.A
100.B.1 100.B.2
101102103104105106107108109110
100.B.3
A7.3 1
A8.2
A A A A A A A A A
3'-0" 28'-9" 3 1/2" 13'-0" 3 1/2" 13'-0" 3 1/2" 13'-0" 3 1/2" 13'-0" 3 1/2" 24'-0 3/4" 3 1/2" 10'-6" 3 1/2" 10'-6" 3 1/2" 10'-6" 3 1/2" 10'-6"
VERIFY
1' -9
'-3
1/
2" 7'
-4
/4
V
ER
IF
Y
UP
'-0
3/ 4"
5' -1
1" 9"
1' -1
1/
4"
'-6
4'
-6
3'-0"
105B110B4' -0
3'-0"
'-0
±7 '-7
/4
E
F G F
H H
1/
2"
11"
1' -6
11" 12'-0" 1'-6" 4'-1" 4"
3'-2"
4"
4'-1" 1'-6" 12'-0" 11"
A7.39
A2.2
Drafted By:
Date Drawn:
Project #:
APRIL 2022
YULI J.
ALVAREZ
REVISION # DATE:
This document is released for:
Client Review
Permitting Pricing / Bidding
Construction Permit Re-Submittal
Financing Consultant Distribution
G
SA
D O
W N
TO
W
N S
UI
TE
A
US
TIN
A
V E, W A
C O
, T X
AutoCAD SHX Text Xref ..\..\..\Downloads\x-ex-fp1-2019 06 19.dwg
AutoCAD SHX Text
FRIG
AutoCAD SHX Text
MICRO
AutoCAD SHX Text
COFFEE
FEC
FEC
PLAN NORTH
TRUE NORTH
1 FLOOR PLAN - SECOND FLOOR
SCALE: 1/8" = 1'-0"
CORR
200.A
200.A
SERVER ROOM
EXECUTIVE OFFICE
SUITE CONFERENCE
ROOM
BREAK ROOM
STAIR
100.C
A7.3 2
A7.3
BC
D
3'-0" 19'-1 3/4" 3 1/2" 18'-8 1/2" 7" 16'-0" 3 1/2" 11'-0"
VERIFY
9' -3
/4
201202203
1' -9
'-3
/2
2'-8 1/2"
7'-7 1/4"
1'-0"
10'-0"
'-0
7' -8
DOWN
'-1
1" 3"
6' -9
5' -8
/4
200.B
200.C
GENERAL NOTES:
1. THESE DRAWINGS SHOW A GENERAL INTENT TO RECEIVE A QUALITY FINISHED
PRODUCT. CONTRACTOR SHALL BE RESPONSIBLE TO INCLUDE ALL ITEMS
REQUIRED TO COMPLETE THIS PROJECT IN A FINISHED MANNER, WHETHER
ALL CONDITIONS ARE SHOWN OR NOT.
2. DO NOT SCALE DRAWINGS. NOTED DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALE.
3. ALL INTERIOR DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED.
4. MAINTAIN 1'-6" CLEAR DIMENSION AT ALL DOORS AT LATCH SIDE WHERE
DOORS OPEN TOWARDS YOU. MAINTAIN 1'-0" CLEAR AT ALL DOORS THAT
HAVE BOTH A CLOSER AND A LATCH AT LATCH SIDE WHERE DOOR OPENS
AWAY FROM YOU.
5. ALL WALLS TO BE 3-1/2" WOOD STUD, UNLESS OTHERWISE NOTED.
6. TRANSITION STRIPS TO BE USED AT CHANGES IN FLOORING MATERIAL. REFER
TO ROOM FINISH NOTES.
7. ALL DOOR FRAMES TO BE LOCATED 4" FROM PERPENDICULAR WALL.
KEYED NOTES:
1. OPEN TO ABOVE.
2. ALIGN NEW ENCLOSURE WITH EXISTING FOR A CONSISTENT APPEARANCE.
3. OPEN TO BELOW.
4. REFRIGERATOR BY OWNER.
5. MILLWORK; RE: A7.2.
6. WALL TO BE COVERED IN 19MM (3/4") PLYWOOD IN 4FT X 8FT SHEETS;
BOTTOM OF BOARD TO BE MOUNTED 6" ABOVE FINISH FLOOR. PLYWOOD
SHALL BE A/C GRADE AND FINISHED WITH TWO COATS OF FIRE RETARDANT
PAINT. USE GALVANIZED, ZINC PLATED, OR STAINLESS STEEL HARDWARE WITH
A FLAT HEAD FASTENER. FINISHED INSTALLATION SHALL HAVE FLUSH
APPEARANCE WITH COUNTERSUNK SCREW HEADS.
A2.3
Drafted By:
Date Drawn:
Project #:
APRIL 2022
YULI J.
ALVAREZ
REVISION # DATE:
This document is released for:
Client Review
Permitting Pricing / Bidding
Construction Permit Re-Submittal
Financing Consultant Distribution
G
SA
D O
W N
TO
W
N S
UI
TE
A
US
TIN
A
V E, W A
C O
, T X
AutoCAD SHX Text
HS
AutoCAD SHX Text
SELECT.
AutoCAD SHX Text
COFFEE
AutoCAD SHX Text
COFFEE
AutoCAD SHX Text
U.C. FRIG.
| A000-COVER |
| Sheets and Views |
| A000 |
| A001-ADA |
| Sheets and Views |
| Layout1 |
| A2.0-DEMO FIRST FLOOR |
| Sheets and Views |
| A2.0-DEMO FIRST FLOOR |
| A2.1-DEMO SECOND FLOOR |
| Sheets and Views |
| A2.1-DEMO SECOND FLOOR |
| A2.2-FIRST FLOOR |
| Sheets and Views |
| A2.2-FIRST FLOOR |
| A2.3-SECOND FLOOR PLAN |
| Sheets and Views |
| A2.3-SECOND FLOOR |
| A6.1-RCP |
| Sheets and Views |
| A6.1-RCP |
| A6.2-RCP |
| Sheets and Views |
| A6.2-RCP |
| A7.1-FINISH FLOOR PLAN |
| Sheets and Views |
| A7.1-FINISH FLOOR PLAN |
| A7.2-FINISH FLOOR PLAN |
| Sheets and Views |
| A7.2-FINISH FLOOR PLAN |
| A7.3-MILLWORK & INTERIOR DETAILS |
| Sheets and Views |
| A7.3-MILLWORK & INTERIOR DETAILS |
| A8.1-DOOR SCHEDULE & DETAILS |
| Sheets and Views |
| A8.1-DOOR SCHEDULE & DETAILS |
File details come from the government source that posted it. Updated .