A2_Specifications_Pipe-Procurement_Amend3.pdf
PDF 386 KB Posted
- Attached to
- Steel Pipes Federal contract opportunity
- Solicitation number
- W912PM-17-T-0061
About this file
Specifications
View the file
Other files for this federal contract opportunity
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIFICATIONS FOR STEEL PIPE
(FLOATING PLANT)
The contractor shall purchase and deliver Domestic USA Made 12" inch pipe, 10" inch pipe, and Reducing Tee's for use on the U.S. Army Corps of Engineers, Floating Plant vessels.
2. SPECIFICATIONS:
CLIN 0001: Domestic 12" inch Extra Strong A53 rated, Grade B, Seamless Pipe in 40' foot lengths, .500 inch wall thickness, Outside Diameter of 12.750" inches, Inside Diameter of 11.750" inches, 640’ feet of SEAMLESS PIPE / 40' foot sections.
CLIN 0002: Domestic 12" inch Schedule 40 A53 rated, Grade B, Seamless Pipe in 40' foot lengths, .406" inch wall thickness, Outside Diameter 12.750" inches, Inside Diameter 11.938" inches, 320’ feet of SEAMLESS PIPE / 40' foot sections.
CLIN 0003: Domestic 10" inch Extra Strong A53 rated, Grade B, Seamless Pipe in 40' foot lengths, .500" inch wall thickness, Outside Diameter of 10.750" inches, Inside Diameter of 9.750" inches, 640’ feet of SEAMLESS PIPE / 40' foot sections.
CLIN 0004: Domestic - 10" inch x 10" inch x 8" inch Extra Strong A234 Carbon Steel Weld Fitting Reducing Tee with .500" inch wall thickness, 10.750" Outside Diameter and 9.750" inside diameter on the run. 8.62" inch Outside Diameter and 7.635" Inside Diameter on the branch, 24 EA
CLIN 0005: Domestic - 12" inch x 12" inch x 10" inch Extra Strong A234 Carbon Steel Weld Fitting Reducing Tee with .500" inch wall thickness, 12.750" Outside Diameter and 11.750" inside diameter on the run. 10.750" inch Outside Diameter and 9.750" Inside Diameter on the branch, 24 EA
3. DELIVERY: The Pipe shall be shipped to:
U.S. Army Corps of Engineers Engineer Repair Yard 232 Battleship Road Wilmington, North Carolina, 28401 John.b.crabtree@usace.army.mil
The contractor shall ensure that the following are included on the invoice:
• Contract #
• Invoice #
• Company Name
• Invoiced line item(s) must match the contract line items
• Small Business, Veteran Owned, or 8A – If applicable, indicate on invoice.
4.
1. GENERAL:
mailto:John.b.crabtree@usace.army.mil
* Shipping cost shall be included in the contractors quote.
15. Pre-screen candidates using E-Verify Program. Proposed language: "The Contractor must pre screen Candidates using the E-verify Program (http://www.uscis.gov/e-verify) website to meet the established employment eligibility requirements. The Vendor must ensure that the Candidate has two valid forms of Government issued identification prior to enrollment to ensure the correct information is entered into the E-verify system. An initial list of verified/eligible Candidates must be provided to the COR no later than 3 business days after the initial contract award." *When contracts are with individuals, the individuals will be required to complete a Form I-9, Employment Eligibility Verification, with the designated Government representative. This Form will be provided to the Contracting Officer and shall become part of the official contract file.
http://www.uscis.gov/e-verify
File details come from the government source that posted it. Updated .