05_-_Attachment_II_-_Drawing.pdf
PDF 181 KB Posted
- Attached to
- Extend Fire Protection in Building # 2000, Field Camp Algier, USAG Bavaria, Tower Barracks Federal contract opportunity
- Solicitation number
- W912PB-16-B-8111
About this file
Attachment II - Drawing
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 01-02_-_Cover_Letter_IFB.pdf | ||
| 03_-_Solicitation.pdf | ||
| 04_-_Attachment_I_-_Revised_Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE
James M. Beatty, Master Planning
PROJECT NO
DATE DESCRIPTION DRAWN BY APPROVED
PROJECT TITLE
USING UNITDATE
DATE
DATE
DATE
PROJECT ENGR CHECKED BY
SCALE
SHEET
OF
REV NO
NAME (PRINT) NAME (PRINT)
NAME (PRINT)NAME (PRINT)
SIGNATURE SIGNATURE
SIGNATURESIGNATURE
MASTER PLANNER
DRAWN BY
ENGR DIV
DESIGN / PROJ MGMT BR
INSTALLATION
USAG BAVARIA
Grafenwoehr Military Community - Tower Barracks
L. Gruenwald, C/Design Section & Proj Mgmt Br
L. Gruenwald
T30
T30
T30
T30T30T30
ADMIN
SIPR
ADMIN
NIPR
1.50
HV
S C
R E
E N
S C
R E
E N
S C
R E
E N
,3
,2
,5
BEMERKUNG:
NOTE:
John A. Howard, C/Engr Div
M. FroehlerM. Froehler
08.06.2016 EZ-00784-9P
SPRINKLER LAYOUT
1: 100
,8
5,0010,0015,0060,4015,00
D N
DN32
DN32
DN32
DN32
Kassettendecke
Abgehaengte
Sprinklerleitung DN 100
Anschluss an bestehende
DN50
Spuelanschluss
Sprinklerleitung DN 100
Anschluss an bestehende
DN32
SPRINKLER
DN50
Spuelanschluss
Sprinklerleitung DN 100
Anschluss an bestehende
DN100
DN100
D N
D N
D N
D N
DN32
DN32
DN32
DN32
Kassettendecke
Abgehaengte
D N
D N
D N
D N
D N
D N
D N
DN100
DN32
DN32
DN32
DN32
DN32
DN32
DN32
D N
LEGENDE BEMERKUNG:
NOTE:
AUFTRAGNEHMER AN ORT UND STELLE ZU PRUEFEN
SAEMTLICHE MASSE UND BAUZUSTAENDE SIND VOM
DIMENSIONS AT SITE
THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
ANGEPASST WERDEN
NICHT VERPFLICHTEND UND KANN VOM AUFTRAGNEHMER
DIE ANORDNUNG DER SPRINKLER-VERTEILLEITUNGEN IST
OBLIGATORY AND MAY BE ADJUSTED BY THE CONTRACTOR
THE LAYOUT OF THE SPRINKLER DISTRIBUTION LINES IS NOT
E L
E C
T R
E L
E C
T R
E L
E C
T R
BUILDING # 2000
EXTEND FIRE PROTECTION
unter Decke
Hohlraumschutz unter Bodenpodest
Hohlraumschutz
D N
DN100DN100
D N
D N
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
DN32
unter Decke
Hohlraumschutz unter Decke
Hohlraumschutz
Spuelanschluss
Sprinkler haengend
Sprinkler stehend, normal
Sprinkler Strangleitung, nass
Sprinkler Hauptleitung, nass
File details come from the government source that posted it. Updated .