FireExtinguisher15TE5VilseckSprinklerOMA.xls

XLS spreadsheet 41 KB Posted

Attached to
Fire Systems Federal contract opportunity
Solicitation number
W912PB15T3078
Issued by
Department of the Army Materiel Command Expeditionary Contracting Command Regional Contracting Office Bavaria 409th CSB

About this file

TE5

View the file

Other files for this federal contract opportunity

Other files attached to Fire Systems, newest first.
File Type Posted
T-3078_Amend_02.pdf PDF
FireExtinguisher15TE9GrafAnsul.xls XLS spreadsheet
FireExtinguisher15TE7VilseckFireWaterRestraintSystem.doc DOC document
FireExtinguisher15TE1VilseckAnsul.xls XLS spreadsheet
FireExtinguisher15TE17HohenfelsGuardianAFH.xls XLS spreadsheet
FireExtinguisher15TE9GrafAnsul.xls XLS spreadsheet
FireExtinguisher15TE24GarmischSprinklerOMA.xls XLS spreadsheet
FireExtinguisher15TE18HohenfelsSprinklerOMA.xls XLS spreadsheet
FireExtinguisher15TE16HohenfelsGuardianOMA.xls XLS spreadsheet
Solicitation_T-3078_Fire_System.pdf PDF
FireExtinguiserBavariaGFCE_FY15BasicFinal.xls XLS spreadsheet
FireExtinguisher15TE3VilseckGuardianAFH.xls XLS spreadsheet
FireExtinguisher15TE10GrafGuardianOMA.xls XLS spreadsheet
FireExtinguisher15TE2VilseckGuardianOMA.xls XLS spreadsheet
FireExtinguisher15TE20HohenfelsWallHydrants.doc DOC document
FireExtinguisher15TE19HohenfelsSprinklerAFH.xls XLS spreadsheet
Fire_System_Breakout.docx DOCX document
FireExtinguisher15TE23GarmischDry.xls XLS spreadsheet
FireExtinguisher15TE21GarmischAnsul.xls XLS spreadsheet
FireExtinguisher15TE13GrafSprinklerOMA.xls XLS spreadsheet
FireExtinguisher15TE28MaintenanceSchedule.xls XLS spreadsheet
FireExtinguisher15TE12GrafGas.xls XLS spreadsheet
FireExtinguisher15TE25GarmischSprinklerAFH.xls XLS spreadsheet
FireExtinguisher15TE22GarmischGuardianOMA.xls XLS spreadsheet
FireExtinguisher15TE6Vilseck_Sprinkler_AFH.xls XLS spreadsheet
T-3078_Fire_Systems_amend.pdf PDF
FireExtinguisher15TE4VilseckDry.xls XLS spreadsheet
Show all 27

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

TECHNICAL EXIBIT TE-5 VILSECK, SPRINKLER SYSTEMS, OMA
GebäudeHerstellerArtSprinlker nassSprinkler trockenNAV

( * mit Verzögerungs-

einrichtung)TAV mit
SchnellöffnerTrennstation/
KombitrennerRohrtrennerRückschlagklappe
≥DN80≤DN200 / <DN80Steinfänger/
FilterAlarmglockeAuslösetemperaturPulverbehälterNenninhalt

Druckluftwasser-

beälterNenninhalt
VorratsbehälterNenninhalt
VorlagebehälterSprinklerpumpeDruckhaltepumpeKompressorStrömungsmelderÜberwachungsanlageDruckschalter Störung
StadtwasserDruckschalter Störung
SprinklerDruckschalter Alarm
NrStückStückStückStückStückStückStückStückStück°Cm³m³m³m³KWKWSt.St.barbarbar
1102MinimaxSprinkler Sys.202201x DN 150 *1x DN 80--2/21268-----0.5511---0.55
2118MinimaxSprinkler Sys.48-1x DN 150---2/01168--1000.9343-1Schaltschrank--0.55
121Sprinkler Sys.71-1x DN 100---2/21168/141--7.5-221.1-1FMZ 4100---
134Sprinkler Sys.309-1x DN 100---2/21168/93--50.1301.1--FMZ 4100---
215Sprinkler Sys.210-1x DN 80-1-2/01168----13-1-FMZ 41001.321.5
3224Grinell-
HofmannSprinkler Sys.8-1x DN 80---0/21-68-------1----
4226MinimaxSprinkler Sys.200-1x DN 80-1-6/31168---0.1-1.114FMZ 41001.55.55
305Sprinkler Sys.211-1x DN 80-1-1/21168------13FMZ 4100---
6308VIKING
MinimaxSprinkler Sys.219-2 x DN 100 1 x DN 150--12/113680.75--0.4751.1--FMZ 4100--0.6
7352MinimaxSprinkler Sys.63-BAMX *-1-2/11168-------2FMZ 4100--0.55
8353MinimaxSprinkler Sys.63-BAMX *-1-2/11168-------2FMZ 4100--0.55
9400MinimaxSprinkler Sys.861-1x DN 80-1-13/11168---0.515.31.119FMZ 41001.932.5
10401MinimaxSprinkler Sys.927-1x DN 80-1-8/01168----15-16FMZ 410026.56
402Sprinler Sys.1013-1x DN 80-1-6/11168----18.5-16FMZ 4100---
404Sprinkler Sys.1258-1x DN 100---12/01168--13.2-15--10FMZ 5000---
405Sprinkler Sys.1258-1 x DN 100---12/01168--13.2-15--10FMZ 5000---
408Sprinkler Sys.1258-1 x DN 100---12/01168--12.3-18.5--10FMZ 5000---
11553MinimaxSprinkler Sys.25-1x FSV DN80
2x FSV DN100----1-Optisch--100-44---GAB 6---
12606MinimaxSprinkler Sys.702-1x DN 80-1-14/11168---0.5151.1110FMZ 4100254.5
13607MinimaxSprinkler Sys.317-1x DN 100 *---2/12168--700.45144--Schaltschrank--0.55
14608MinimaxSprinkler Sys.700-1x DN 80-1-13/31168---0.1221.1110FMZ 41002.365.5
610Sprinkler Sys.856-1x DN 80-1-14/31168----22-111FMZ 41001.9
15614MinimaxSprinkler Sys.702-1x DN 80-1-13/31168---0.1151.1110FMZ 410022.82.3
16616MinimaxSprinkler Sys.210-1x DN 100 *---2/11168--700.45183--Schaltschrank--0.55
17630MinimaxSprinkler Sys.700-1x DN 80-1-4/11168----111.114FMZ 4100-21.5
18640MinimaxSprinkler Sys.659-1x DN 80-1-1/01168------14FMZ 410012.52
19641MinimaxSprinkler Sys.50-1x DN 150---2/01168-------1---0.55
681Sprinkler Sys.932-1x DN 80-1-12/31168----22-110FMZ 41001.9--
682Sprinkler Sys.932-1x DN 80-1-12/31168----22-110FMZ 41001.9--
695Sprinkler Sys.5701 x DN 1001 x DN 80--8/11268--22.8-371.117FMZ 5000--0.55
697-699Sprinkler Sys.233-3x DN 80-1-0/41368----30-1-FMZ4100---
701Sprinkler Sys.146-1x DN 80-1-1/01168------1-FMZ41001.53.83.3
20728MinimaxSprinkler Sys.234201x DN 1501x DN 80--2/21268/93-----0.5511---0.8
241704MinimaxSprinkler Sys.-8-1x DN 80 vorgest.-11/11168------11FMZ 41001.52.10.55
352203MinimaxSprinkler Sys.9381062x DN150 *---5/21268-22.53000.4575411Schaltschrank--0.55
362207MinimaxSprinkler Sys.132101x DN 100 *1x DN 80--0/21268------1-Schaltschrank--0.55
372234?Sprinkler Sys.11----3-3-68-------6----
382237MinimaxSprinkler Sys.134-1x DN 150 *---1/01168--60-22---Schaltschrank--0.55
5000Sprinkler Sys.269-1 x DN 100---5/51168--31-551.1-6FMZ 5000--0.55

Sheet2

Sheet3

File details come from the government source that posted it. Updated .