FireExtinguisher15TE18HohenfelsSprinklerOMA.xls

XLS spreadsheet 42 KB Posted

Attached to
Fire Systems Federal contract opportunity
Solicitation number
W912PB15T3078
Issued by
Department of the Army Materiel Command Expeditionary Contracting Command Regional Contracting Office Bavaria 409th CSB

About this file

TE18

View the file

Other files for this federal contract opportunity

Other files attached to Fire Systems, newest first.
File Type Posted
T-3078_Amend_02.pdf PDF
FireExtinguiserBavariaGFCE_FY15BasicFinal.xls XLS spreadsheet
FireExtinguisher15TE3VilseckGuardianAFH.xls XLS spreadsheet
FireExtinguisher15TE10GrafGuardianOMA.xls XLS spreadsheet
FireExtinguisher15TE2VilseckGuardianOMA.xls XLS spreadsheet
FireExtinguisher15TE20HohenfelsWallHydrants.doc DOC document
FireExtinguisher15TE28MaintenanceSchedule.xls XLS spreadsheet
FireExtinguisher15TE12GrafGas.xls XLS spreadsheet
FireExtinguisher15TE25GarmischSprinklerAFH.xls XLS spreadsheet
FireExtinguisher15TE22GarmischGuardianOMA.xls XLS spreadsheet
FireExtinguisher15TE6Vilseck_Sprinkler_AFH.xls XLS spreadsheet
T-3078_Fire_Systems_amend.pdf PDF
FireExtinguisher15TE5VilseckSprinklerOMA.xls XLS spreadsheet
FireExtinguisher15TE4VilseckDry.xls XLS spreadsheet
FireExtinguisher15TE19HohenfelsSprinklerAFH.xls XLS spreadsheet
Fire_System_Breakout.docx DOCX document
FireExtinguisher15TE23GarmischDry.xls XLS spreadsheet
FireExtinguisher15TE21GarmischAnsul.xls XLS spreadsheet
FireExtinguisher15TE13GrafSprinklerOMA.xls XLS spreadsheet
FireExtinguisher15TE9GrafAnsul.xls XLS spreadsheet
FireExtinguisher15TE7VilseckFireWaterRestraintSystem.doc DOC document
FireExtinguisher15TE1VilseckAnsul.xls XLS spreadsheet
FireExtinguisher15TE17HohenfelsGuardianAFH.xls XLS spreadsheet
FireExtinguisher15TE9GrafAnsul.xls XLS spreadsheet
FireExtinguisher15TE24GarmischSprinklerOMA.xls XLS spreadsheet
FireExtinguisher15TE16HohenfelsGuardianOMA.xls XLS spreadsheet
Solicitation_T-3078_Fire_System.pdf PDF
Show all 27

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

TECHNICAL EXIBIT TE-18 HOHENFELS, SPRINKLER SYSTEMS OMA
GebäudeHerstellerArtSprinlker nassSprinkler trockenNAV

( * mit Verzögerungs-

einrichtung)TAV mit
SchnellöffnerTrennstation/
KombitrennerRohrtrennerRückschlagklappe
≥DN80≤DN200 / <DN80Steinfänger/
FilterAlarmglockeAuslösetemperaturPulverbehälterNenninhalt

Druckluftwasser-

beälterNenninhalt
VorratsbehälterNenninhalt
VorlagebehälterSprinklerpumpeDruckhaltepumpeKompressorStrömungsmelderÜberwachungsanlage
NrStückStückStückStückStückStückStückStückStück°Cm³m³m³m³KWKWSt.St.
13MinimaxSprinkler Sys.132-1x DN 80--2/21268-----0.5511Schaltschrank
26MinimaxSprinkler Sys.65-1x DN 150---2/01168--1000.9343-1-
7Sprinkler Sys.60-1x DN 150-1-2/21168/141--7.5-221.1-24FMZ 4100
9Sprinkler Sys.150-1x DN 80-1-2/01168----13-1-FMZ 4100
310AGrinell-
HofmannSprinkler Sys.165-1x DN 80---0/21-68-------1-
414MinimaxSprinkler Sys.203-1x DN 80-1-6/31168---0.1-1.114FMZ 4100
623VIKING
MinimaxSprinkler Sys.240-?--12/113680.75--0.4751.1--FMZ 4100
744MinimaxSprinkler Sys.6-1x DN 80-1-2/11168-------2FMZ 4100
848MinimaxSprinkler Sys.4-1x DN 65-1-2/11168-------2FMZ 4100
954MinimaxSprinkler Sys.14-1x DN 80-1-13/11168---0.515.31.119FMZ 4100
1070MinimaxSprinkler Sys.151-1x DN 80-1-8/01168----15-16FMZ 4100
70ASprinkler Sys.151-1x DN 80-1-6/11168----18.5-16FMZ 4100
1171MinimaxSprinkler Sys.59-1x DN 80----1-Optisch--100-44----
1272MinimaxSprinkler Sys.80-1x DN 80-1-14/11168---0.5151.1110FMZ 4100
1388MinimaxSprinkler Sys.80-1x DN 80---2/12168--0.5144--Schaltschrank
14100MinimaxSprinkler Sys.740-1x DN 100-1-13/31168--500.1221.1110FMZ 4100
100GSprinkler Sys.80-1x DN 100-1-14/31168----22-111FMZ 4100
15111MinimaxSprinkler Sys.12-1x DN 80-1-13/31168---0.1151.1110FMZ 4100
16112MinimaxSprinkler Sys.132-1x DN 150 *-1-2/11168--0.45183--Schaltschrank
17150MinimaxSprinkler Sys.185-1x DN 80-1-4/11168----111.112FMZ 4100
18330MinimaxSprinkler Sys.37-1x DN 80-1-1/01168------11FMZ 4100
19338MinimaxSprinkler Sys.37-1x DN 150---2/01168-------1-
339Sprinkler Sys.37-1x DN 80-1-12/31168----22-110FMZ 4100
340Sprinkler Sys.37-1x DN 80-1-12/31168----22-110FMZ 4100
341Sprinkler Sys.37-3x DN 80-1-0/41168----30-1-FMZ4100
20343MinimaxSprinkler Sys.371-2/21168-----0.551-
21361MinimaxSprinkler Sys.65--1-2/01168------11FMZ 4100
22369MinimaxSprinkler Sys.46-1x DN 80-1-2/01168-----1-FMZ 4100
23371MinimaxSprinkler Sys.59-1x DN 80-1-2/01168---0,5--1-FMZ 4100
24387MinimaxSprinkler Sys.591x DN 80-11/11168------11FMZ 4100
25511MinimaxSprinkler Sys.139-1x DN 80--1-1-68-------1-
26514MinimaxSprinkler Sys.139-1x DN 80-1-1168-------1-
27525MinimaxSprinkler Sys.130-1x DN 80---1168--180-100---
28534MinimaxSprinkler Sys.56-1x DN 80--1-1-68---0,555-13-
29535MinimaxSprinkler Sys.160-1x DN 1501-1-68--------
30536MinimaxSprinkler Sys.500-2x??-1-1-68----37---
31703MinimaxSprinkler Sys.34-1x DN 80-1-2/01168------1FMZ 4100
32710MinimaxSprinkler Sys.34-1x DN 80-1-1168--------
33748MinimaxSprinkler Sys.65-1x DN 80 1x DN150---2/011683 (Schaum)-50--3.41FMZ 4100
34853MinimaxSprinkler Sys.145-1x DN 80-1-2/01168---0,515-1FMZ 4100
35855MinimaxSprinkler Sys.1451x DN 80-1-168-0,515
36982MinimaxSprinkler Sys.17--0/21268------1-
371123?Sprinkler Sys.17-----168------1-
381306MinimaxSprinkler Sys.54-1x DN 80---168------
1307Sprinkler Sys.41-1x DN 801x DN 80168
1312Sprinkler Sys.41-1x DN 801x DN 80168