C
B
A
4 3 2
RAILROAD
1RES1LE
B
DCB 724
DECK CARGO BARGE, TYP
MISSISSIPPI RIVER
CIN FLOATS, TYP
LOCATION PLAN
SCALE; 1"= 100'
GENERAL CONSTRUCTION NOTES
1. ALL WORK SHOWN ON THE MECHANICAL PIPING DRAWINGS !S BASE BID.
2. ALL PIPING SHALL FOLLOW THE GENERAL ARRANGEMENT SHOWN. PIPING SHALL BE
RUN ESSENTIALLY AS INDICATED, CARE BEING TAKEN TO AVOID INTERFERENCE WITH
OTHER PIPING, CONDUIT, OR EQUIPMENT. THE LOCATION OF PIPING TO BE RUN ON
DOCKS SHALL BE CAREFULLY COORDINATED WITH DOCK STRUCTURE AND ELECTRICAL
CONDUITS SPECIFIED. BEFORE JOINTING AND ERECTION OF PIPING, THOROUGHLY
CLEAN INTERIORS OF PIPE AND COMPONENTS. MAINTAIN CLEANLINESS BY CLOSURE
OF PIPE OPENINGS WITH CAPS OR PLUGS.
3. THE CONTRACTOR SHALL MAINTAIN THAT SUFFIC!ENT PIPE FLEXIBILITY AND ANCHORAGE
IS PROVIDED FOR ALL LINES FOR THERMAL EXPANSION AND CONTRACTION, PRESSURE
AND DOCK FLEXING, THE PIPING SHALL BE PROPERLY SUPPORTED AND ANCHORED.
SHORT SECTIONS OF HOSE MAY BE CONSIDERED FOR PW AND SEWER SERVICE, UPON
APPROVAL.
4. CONTRACTOR SHALL INSPECT MATERIALS DELIVERED TO SITE FOR DAMAGE. UNLOAD
AND STORE WITH MINIMUM HANDLING. STORE MATERIALS ON SITE IN ENCLOSURES OR
UNDER PROTECTIVE COVERING. DO NOT STORE MATERIALS DIRECTLY ON THE GROUND.
KEEP JNSIDE OF PIPES, FITTINGS AND EQUIPMENT FREE OF DIRT AND DEBRIS.
HANDLE PIPE, FITTINGS, VALVES, AND OTHER ACCESSORIES IN SUCH MANNER AS TO
ENSURE DELIVERY TO THE DOCKS AND INSTALLATION LOCATION IN A SOUND
UNDAMAGED CONDITION.
5. ALL MATERIALS (PIPE, VALVES, ETC.) SHALL BE FURNISHED BY THE CONTRACTOR. ALL
SUCH MATERIALS SHALL BE NEW, SHALL MEET CllY, COUNlY, AND WATER UTllllY
COMPANY AND OTHER AHJ SPECIFICATION REQUIREMENTS FOR EACH ITEM, AND PR!OR
TO INSTALLATION, BE APPROVED IN WRITING BY THE ARMY CORPS OF ENGINEERS.
6. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE UNIFORM PLUMBING
CODE, LATEST EDITIONS, AS APPLICABLE.
7, THE CONTRACTOR SHALL VERIFY ALL EXISTJNG UTILllY LOCATIONS IN THE FIELD
BEFORE STARTING WORK. THE CONTRACTOR SHALL FIELD VERIFY THE POINT OF
CONNECTIONS AND MATERIALS AT POINT OF CONNECTION. LOCATIONS OF PIPING AND
APPURTENANT FITTINGS SHOWN ON THE PLANS (DRAWINGS) ARE APPROXIMATE. lT JS
INTENDED THAT SUCH ITEMS BE LOCATED BASED ON EXACT LOCATIONS DETERMINED
IN THE FIELD AND THE DIMENSIONS, ANCHORING REQUIREMENTS, ACCESS
REQUIREMENTS, ETC., OF THE SUPPLIED MATERIALS.
P:\6873 St Louis Mooring Replacemeot\CADD\SU8MITTAL\276B•M1,dwg 13 Jul 2010 -2:26pm
8. THE CONTRACTOR SHALL PROVIDE PROTECTIVE MfASURES TO SAFEGUARD EXISTING
UTILITIES TO REMAIN FROM DAMAGE DURING CONSTRUCTION OF THIS PROJECT.
9. CONSTRUCTION EQUIPMENT AND MATERIAL MAY BE STORED ONLY IN AREAS
DESIGNATED FOR CONTRACTOR'S USE.
10. THE CORPS SERVICE BASE OFFICER JN CHARGE WILL HAVE THE AUTHORllY TO
DESIGNATE AND/OR LIMIT AREAS OF CONSTRUCTION. DRAWINGS INDICATE EXISTING
PIPING TO BE REMOVED, BUT CONFIGURATION OF PIPING TO BE REMOVED VARIES ON
EACH FLOAT. CONTRACTOR SHALL VERIFY WITH BASE OFFICER IN CHARGE SPECIFIC
PIPING WHICH IS TO BE REMOVED.
11. SUPPORTS AND HARDWARE SHALL BE FROM MANUFACTURED SHAPES, FIELD BENDING
!S NOT PERMITTED. SUBMIT SHOP DRAWINGS OR CATALOG DATA FOR REVIEW AND
APPROVAL.
12. DIELECTRIC COUPLINGS SHALL BE USED AT DISSIMILAR METAL PIPING CONNECTIONS.
13. CONTRACTOR SHALL PROVIDE TEMPORARY BLOW OFF VALVES AT THE END OF EACH
WATER LINE, TO BE REMOVED WHEN INSTALLATION IS COMPLETE.
DELONG BARGE
LEGEND AND ABBREVIATIONS
Sl'.Ml.lQl.S hllBBEI' DESCRIPTION
AHJ AUTHORITY HAVING JURISDICTION
BFP BACKFLOW PREVENTION DEVICE
BV BALL VALVE
CONN CONNECTION
CONT CONTINUATION
DIA DIAMETER
DWG DRAWING
ELL ELBOW
EXIST. EXISTING
FT FEET
GALV GALVANIZED
GV GATE VALVE
_f_ HB HOSE BIBB LOPE LOW DENSllY POLYETHYLENE
MAX MAXIMUM
MIN MINIMUM
MFR MANUFACTURER
NPT NATIONAL PJPE THREAD
NTS NOT TO SCALE
� POC POINT OF CONNECTION
-PW- PW POTABLE WATER
RED REDUCER
ss STAINLESS STEEL
STD STANDARD
STL STEEL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
W/ l',qTH
100' o· 100' 200·
SCALE: 1"=100'
m USArmyCorp• of Engineers Marina Deslgo canter 100 Penn Sqo�re Ea.I PMlad�lphla, PA 19,07
Zl!6lic.oJ.JFOON"'il.VO,:a..tE.OO Wi.JurCRW<."""""'° j l ii� � 5 ii g
� 0
1;; .... !;: !;l � m � I ; 0 � I I . '
3 l,I I;� " ' 0 o 0 f
§ ffi '� w � tU � i � Q � �
Ii 1o l :rn l � fii
• C I ! ffi � • I w z UJ Q CJ) t,z
� :::,Q a: I-t;!f
� zil'.i Oa:
""' ...,m
0 << 0 a: 0 :,; Wz
Z<(
UJ UJ"
i "zz�� UJ ::Sw Id C...., 5c 5 fff
�b� uz
Sheet reference number
M1 b3odnnrw Line b3odnnrw Line b3odnnrw Line b3odnnrw Line b3odnnrw Line b3odnnrw Text Box Existing V3 Page 1 b3odnnrw Line b3odnnrw Line b3odnnrw Text Box Pipes to be replaced b3odnnrw Line b3odnnrw Oval
Text Box Existing V3 Page 2
Existing V3 Page 3 b3odnnrw Line b3odnnrw
3” to 2” reducer located south of the trestle
Existing V3 Page 4
Existing V3 Page 5
Existing V3 Page 6
Existing V3 Page 7
Historical V2
Historical V2 Page 2
Historical V1 Page 1
| [Untitled] |
| Warf Drawing Capture |
| [Untitled] |