TEMF_Drawing_(Volume_4_of_4).pdf
PDF 4 MB Posted
- Attached to
- Tactical Equipment Maintenance Facility Federal contract opportunity
- Solicitation number
- W912HV-17-B-0002
About this file
Drawings (Volume 4 of 4)
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Abstract_-_TEMF_W912HV-17-B-0002.pdf | ||
| W912HV-17-B-0002,_Amendment_0002.pdf | ||
| W912HV-17-B-0002,_Am-0002_(Combined_Drawings).pdf | ||
| W912HV-17-B-0002,_Am_0002_-_Revised_Specs.pdf | ||
| Amendment_0001_-_TEMF_(extend_response_date).pdf | ||
| TEMF_Drawing_(Volume_2_of_4).pdf | ||
| OneTime_Multiple_Access_Roster_USAG-J_Form_1529-1.pdf | ||
| TEMF_Drawing_(Volume_3_of_4).pdf | ||
| OneTime_Multiple_Access_Roster_USAG-J_Form_1529.pdf | ||
| Solicitation_W912HV-17-B-0002.pdf | ||
| TEMF_Specifications.pdf | ||
| TEMF_Drawing_(Volume_1_of_4).pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EASEMENT FOR
DRAINAGE PIPE LINE
EASEMENT FOR
DRAINAGE PIPE LINE
SAKAI RIVER
FAC3157-01
20'W X 951.9'L
FAC3084
6'W X 424'L
SAKAI RIVER
SA
KA
I R
IV
ER
SAKAI RIVER
SAKAI RIVER
SAKAI RIVER
DRAINAGE LINE
EASEMENT
M H
M H
C B
M H
M
HM
H M
H
M H
M H
M
HM
H
SIG
N
GP
M H
M H
M H
M H
C B
M H
C B
C B
C B C
B
CB
M H
SIG
N
C B
C B
C B
TL
TL
SIGNM
HM
H
M
HM
H
C B
C B
M H
M H
M H
M H
M H
C B
M H
M H
M H
M H
GW's
GARDEN
M H
CIT
Y S
TO
RM D
IT
CH
8TH STREET
7TH STREET
5TH STREET
"H " A
V E
N U
E
"G " A
V E
N U
E
"F " A
V E
N U
E
6TH STREET
7TH STREET
"B " A
V E
N U
E
"A " A
V E
N U
E
"E " A
V E
N U
E
"D " A
V E
N U
E
4TH STREET
3RD STREET
"C " A
V E
N U
E
1S T S T R EE T
3RD STREET
2N D S T R E ET
4TH STREET
M H
M H
M H
M H
M H
M H
M H
M H M
H
M H
M H
M H
M
HM
H
M H
M H
M H
C B
M H
SIG
N
M H
M H
M H
M H
SIG
N
GUY POLE
CB
CB
TRAFFIC
MIRROR TRAFFIC
MIRRORS
GW
SIG
N
M H
M H
M H
MH
M
H
M H
M H
M H
SIGN
M H
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB
CB CB
M H
M H
M H
M
H CB
M
HCB
M H
M H
M H
M H
GP
M H
M H
M H
M H
M H
M H
M H
M H
GW
M H
M H
M H
M H
M H
S IGN
GP
C B
M H
M H
GP
G. INLET
M
H
M
HM
H
M H
M H
M H M
H
M H
M H
M H
M H
M H
M
HM
H
M
HM
H
M H
C B
CB
C B
M H
M H M
H
C B
C B
GP
GW
M H
C B
M H
M H
M H
C B
C B
M H
C B
CB
M H
M H
M H
M H
M H
M H
M H
M H
M H
M H
M H
M H
M H
M H M
H M
H
MH
SIG
N
CB
C
B
CB
C
B C B
C B
SIGN
TL
C B
TL
SIG
N
C B
C B
TL
TL
M H
TL
M H
M H
M H
M H
M H
M H
M H
M H
M H
M H
M
HM
H
C B C B
M H
C B
C B
C B
M
HM
H
M H
M H M
H
M H
M H
M H
M H
C B
M H
C B
C B
C B M
H
M H
C
BC
B
M H
C B
M H
C B
C B
C B
M H
C B
M H
C B
M H
M H
GA
TEM
H
M H
M H
M H
M H
M H
M H
C B
C B
SIG
N
GP
GW
GW
C B
C B
SIG
N
M H
C B
M H
SIG
N
C B
M H
M H
C B
SIG
N
C B
M H
M H
M H
M H
C B
M
HSIG
N
SIG
N
M H
M
HM
H
M H
C B
C B
C B
C B
C B
C B
C B
C B
M H
C B
C B
C B
M H
M H
M
HC
B
C B
SIG
N
C B
C B
C B
M H
C B
C B
C B
M
HM
H
C B
SIG
N
C B
C B
M H
C B
C B
C B
C B
C B
SIG
N
M H
HH
M H
M H
M H
M H
M H
M H
M H M
H
M H
M H
C B C B
C B
C B
C B
C B C B
CB
SIGN's
SIGN
GW
M H
C B
C B
C B
C B
C B
M H
C B
C B
C B
M H
C B
CB
CB
CB
CB
CB
CB
CB
C B
CB
M H
M H
M
H SIG
N
M H
M H
M H
SIG
NGW
M H
M H
M H
M H
M H
C B
HH
M H
C B
TL
TL
M H
C B
C B
C B
C B
C B
HH
SIG
N
SIG
N
C B CB C B CB
M
H
M H
M H
M H
M H
C B
CB
C B M
H
SIG
N
SIG
N
SIG
N
SIG
N
SIG
N
SIG
N
M H
M H
M H
M
HM
H
M
HM
H
M H
M H
M H
M H
M H
M H
C B
M H
M H
GP's
M H
M H
M H
M H
M H
M
HM
H
M H
M
HM
HM
H
SIGN
GATE
RR SIGNAL
RR SIGNAL
M H
OBSCURED OBSCURED
DRAIN INLETS
M H
M H
M H
SIG
N
M
HM
H
SIG
N
GW
S
R E
T A
I N I N
G W
A
LL
RETAININ
G W
ALL
R E
T A
IN
IN
G W
A L
L
GARDEN
GARDEN
GARDEN
R E
T . W
A
LL
S
GARDEN
GARDEN
PARKING
PARKING
GARDEN
GARDEN
GARDEN
PARKING
PARKING
JUNK YARD
PARKING
P A
R K
IN
GP
A R
K
IN
G P A
R K
IN
G
P A
R K
IN
G
POND
P O
N D
PARKING
PARKING
P A
R K
IN
G
PARKING
GA
TE
PARKI
NG
PARKI
NG
PARKI
NG
PARKING
TANKS
RETA
IN
ING
W
ALL
TANKS
P A
R K
IN
G
P A
R K
IN
G
UNDER CONSTRUCTION
UNDER CONSTRUCTION
ASPHALT
ASPHALT
CONC. RAMP
CONC. RAMP
P A
R K
IN
G
PARKING
PARKING
PARKINGPARKING
PARKING
RET. WALL
POND
TANK
CONSTRUCTION
AREA
COVERED
PARKING
POND
UNDER CONSTRUCTION
UNDER CONSTRUCTION
UNDER CONSTRUCTION
ASPHALT
ASPHALT
ASPHALT
C O
N C
. D
IT
C H
P A
R K
IN
G
GARDEN
P A
R K
IN
G
PL
AY
G
RO
U N
D
127.5
127.4
RET. WALL
GATE
4TH STREET
FOP
GATE
O.T
GATE
GATE
GATE
GATE
PARKING
161-T15
143-T9
143-T10
5TH STREET
6TH STREET
7TH STREET
8TH STREET
GATE
ROAD EASEMENT
50'W X 250'LFAC3157-02
US ARMY CORPS
OF ENGINEERS
JAPAN ENGINEER DISTRICT
A
D A
T E
D
E S
IG
N
E D
B Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
T
R
IC
T , J
A P
A N
C O
R P
S O
F E
N G
IN
E
E R
S A
P O
A P
8-
Sheet Reference Number:
B C D E F G H
S C
A
LE
D R
A W
IN
G
C O
D E
A1 Size 594mm x 841mm
P R
O
JE
C T
E N
G
IN
E E
R /A
R C
H
IT
E C
T
D
A T
E
R
EV
D
ES
C R
IP
TI
O N
D
AT
E
AP
R
THIS PROJECT WAS REVIEWED BY JAPAN DISTRICT OF THE U.S ARMY CORPS OF ENGINEERS. THE INITIALS OR SIGNATURES AND REGISTRATION DESIGNATIONS OF INDIVIDUALS APPEAR ON THESE DOCUMENTS WITHIN THE SCOPE OF THEIR EMPLOYMENT AS REQUIRED BY ER 1110-1-8152.
SECTION/DETAIL CROSS REFERENCING CONVENTIONS
SECTION IDENTIFICATION NUMBER
NUMBER OF SHEET ON WHICH
SECTION IS DRAWN
3 DETAIL IDENTIFICATION NUMBER
NUMBER OF SHEET ON WHICH
DETAIL OF THE CONDITION IS
DRAWN
GI001
GI001
DIRECTION
GI001
DETAIL
DRAWING TITLE
SCALE
DRAWING SCALE
SECTION
DRAWING TITLE NUMBER
AE101
ELEVATION
ELEVATION IDENTIFICATION NUMBER
NUMBER OF SHEET ON WHICH
ELEVATION IS DRAWN
A
B
C
D DIRECTION
U.S. ARMY ENGINEER DISTRICT, JAPAN
DATE
DATE
PROJECT MANAGER
REID S. OSHIRO, P.E.
CHIEF, ENGINEERING BRANCH
HOKKAIDO
MISAWA AB
HONSHU
YOKOTA AB
NAF ATSUGI
YOKOSUKA NB
IKEGO
IWO JIMA
SHIKOKU
SASEBO NB
OKINAWA
KYUSHU
MCAS IWAKUNI
CAMP FUJI
CAMP ZAMA
SAGAMIHARA HOUSING AREA
SAGAMI GENERAL DEPOT
VICINITY MAP
NORTH
LOCATION PLAN
ENGINEERING AND CONSTRUCTION
DIVISION
US ARMY ENGINEER DISTRICT, JAPAN
APO AP 96338-5010
SA
G
AM
I G
EN
ER
AL
D
EP
O
T, J
AP
AN
SAGAMI GENERAL DEPOT, JAPAN
FY13 MCA PN62663
A P
P R
O V
E D
B Y
TACTICAL EQUIPMENT MAINTENANCE FACILITY
ARCHITECTURAL
THIS WORK WAS PREPARED BY
ME OR UNDER MY SUPERVISION
STRUCTURAL
THIS WORK WAS PREPARED BY
ME OR UNDER MY SUPERVISION
MECHANICAL / PLUMBING
THIS WORK WAS PREPARED BY
ME OR UNDER MY SUPERVISION
FIRE PROTECTION
THIS WORK WAS PREPARED BY
ME OR UNDER MY SUPERVISION
ELECTRICAL
THIS WORK WAS PREPARED BY
ME OR UNDER MY SUPERVISION
NORTH
PROJECT LOCATIONS
TA
C
T I C
AL
E
Q U
IP
M
E N T
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
JU
L
JU
L
LE
ID
O S
E N
G
IN
E E
R
IN
G , L
LC
N
. B R
O A
D W
A Y
, S U
IT
E
O K
LA
H
O M
A C
IT
Y
, O K
5-
8-w w w
.L E
ID
O
S .c om /e ng in ee rin g
W R
R
KI
G
KI
G
FY
1 3
M C
A
PN
O R
G
AN
IZ
A T
IO
N
AL
S
TO
R
AG
E
BU
IL
D
IN
G (V
O
LU
M E
O
F 4)
KA
L
ORGANIZATIONAL STORAGE BUILDING (VOLUME 4 OF 4)
C O
V E
R S
H E
E T
G-000
SCHEDULE OF DRAWINGS
SHEET NO. SHEET NAME REV.
F-101 FIRE ALARM AND FIRE SUPPRESSION FLOOR PLAN
F-601 FIRE ALARM AND MNS SINGLE LINE DIAGRAM
F-602 FIRE SUPPRESSION DETAILS AND DIAGRAM
MECHANICAL
M-001 GENERAL NOTES, ABBREVIATIONS AND SYMBOLS LEGEND
M-101 HVAC PLAN
M-501 HVAC SCHEDULES AND DETAILS
MI801 EXHAUST FAN AND UNIT HEATER
ELECTRICAL
E-001 LEGEND AND ABBREVIATIONS
EG101 GROUNDING AND LIGHTINING PROTECTION PLAN
EG501 GROUNDING & LIGHTNING PROTECTION DETAILS
EG502 GROUNDING & LIGHTNING PROTECTION DETAILS
EL101 LIGHTING PLAN
EP101 POWER PLAN
TELECOMMUNICATIONS
T-001 TELECOMMUNICATIONS LEGEND AND ABBREVIATIONS
T-101 TELECOMMUNICATIONS FLOOR PLAN
T-501 TELECOMMUNICATIONS DETAILS
SHEET NO. SHEET NAME REV.
GENERAL
G-000 COVER SHEET
GI001 LIFE SAFETY CODES ANALYSIS AND FLOOR PLAN
STRUCTURAL
S-001 GENERAL NOTES AND DESIGN LOADS
S-002 TYPICAL DETAILS
S-003 MISCELLANEOUS TYPICAL DETAILS
S-004 TYPICAL BRACE DETAILS
S-101 FOUNDATION PLAN AND ROOF FRAMING PLAN
S-201 WALL ELEVATIONS
S-301 SECTION
S-401 BEAM ELEVATIONS
ARCHITECTURAL
A-001 ARCHITECTURAL GENERAL NOTES AND ABBREVIATIONS
A-101 FLOOR PLAN AND ROOF PLAN
A-201 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-302 WALL SECTIONS
A-501 PLAN & SECTION DETAILS
A-601 DOOR SCHEDULE & DETAILS
INTERIORS
I-101 SIGNAGE PLAN, SCHEDULE AND DETAILS
FIRE PROTECTION
F-001 SYMBOLS AND LEGENDS
OPTION TWO
R
EV
D
ES
C R
IP
TI
O N
D
AT
E
AP
R R
TA
/1 2/
1 6
B
2 3 4 5
ORGANIZATIONAL
STORAGE
S100
13.0 M(13.0 M)
12.4 M(12.4 M)
FEBFEBFEBFEB
FEB
13.5 M(13.5 M)
5 MM
914 MM
5 MM
914 MM
5 MM
914 MM
5 MM
914 MM
5 MM
914 MM
GENERAL NOTES:
1. GENERAL INFORMATION (GI) SHEETS ARE FOR INFORMATION ONLY.
2. ALL DRAWINGS ARE DIAGRAMMATIC IN NATURE AND SHALL NOT BE
USED FOR EXACT MEASUREMENT, DESIGN, OR FABRICATION.
3. CONTRACTOR SHALL COORDINATE INSTALLATION OF EVERY SYSTEM
COMPONENTS WITH ALL OTHER TRADES.
X = TRAVEL DISTANCE IN METER; Y = COMMON PATH DISTANCES IN METER
STORAGE GROUP S-1 / STORAGE (NO HATCH)
OCCUPANT LOAD
CALCULATED REQUIRED EXIT WIDTH IN MM
PROVIDED EXIT WIDTH (CLEAR) IN MM
WALL MOUNTED EXIT LIGHTS
CEILING MOUNTED EXIT LIGHTS
FIRE EXTINGUISHER BRACKET (FEB) FOR 10 LB DRY CHEM TYPE (2A-20B-C)
LIFE SAFETY LEGEND:
X M (Y M)
FEB
XXX
XX MM
XX MM
EGRESS ARRANGEMENT: NFPA TABLE A.7.6.1
MAXIMUM DISTANCE LIMITS, M
OCCUPANCY COMMON PATH DEAD END CORRIDOR TRAVEL DISTANCE
STORAGE (S-1), SPRINKLERED 30 30 122
MINIMUM NUMBER OF EXITS REQUIRED: NFPA 101 7.4.1.1
FIRST FLOOR: TOTAL OCCUPANCY: 6:
NOT LESS THAN 2 EXITS REQUIRED NFPA 101 7.4.1.2 (1)
6 EXITS PROVIDED ACTUAL DESIGN
A SINGLE EXIT IS PROVIDED FROM EACH STORAGE SECTION. THE EXIT CAN BE REACHED WITHIN 30 M: NFPA 101 42.2.4.1 (2).
EGRESS DOOR SWING: NFPA 101 7.2.1.4.2
SWING IN THE DIRECTION OF EXIT TRAVEL SERVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS
ACCESSIBLE MEANS OF EGRESS:
ACCESSIBLE EGRESS IS PROVIDED TO ACCESSIBLE EXITS NFPA 101 7.5.4 & 7.2.12
ACCESSIBILITY STANDARD: ICC/ANSI A117.1 (NFPA 101 A7.5.4.1), ABA,UFAS
MINIMUM ACCESSIBLE EXITS: 2 ACCESSIBLE EXITS PROVIDED
ILLUMINATION OF MEANS OF EGRESS: NFPA 101 7.8.1.3
1. THE MINIMUM ILLUMINATION FOR FLOOR AND WALKING SURFACES SHALL BE TO VALUES OF AT LEAST 1 FT-CANDLES (10.8 LUX)
MEASURED AT THE FLOOR.
2. THE MINIMUM ILLUMINATION REQUIREMENTS SHALL NOT APPLY WHERE OPERATIONS OR PROCESSES REQUIRE LOW LEVEL LIGHTING.
EMERGENCY LIGHTING: NFPA 101 7.9.1.3 & 7.9.2.1
EMERGENCY LIGHTING WILL BE DESIGNED TO ACTIVATE WITHIN 10 SECONDS OF PRIMARY POWER FAILURE AND OPERATE INDEFINITELY ON
BATTERY POWER.
EXIT AND EXIT ACCESS MARKINGS: NFPA 101 7.10.1.1, 7.10.1.3, 7.10.1.5
OSB SIGNAGE MEETING ICC/ANSI A117.1 WILL BE PROVIDED AT EACH EXIT DOOR THAT REQUIRE AN EXIT SIGN. ALSO, EXIT SIGNS SHALL
BE PROVIDED IN A MANNER SO THAT NO POINT IS MORE THAN 100 FT FROM A SIGN.
FIRE EXTINGUISHERS:
HAZARD CLASSIFICATION: CLASS A, B & C NFPA 10 4.2.1
STORAGE AREAS- ORDINARY (MODERATE) HAZARD
EXTINGUISHER DESIGN BASIS: 2A-20B-C DRY CHEMICAL EXTINGUISHER
BUILDING AREA CLASSIFICATION PER NFPA 10 ORDINARY (MODERATE) HAZARD.
MAXIMUM TRAVEL DISTANCE TO AN EXTINGUISHER23 M
MAXIMUM COVERAGE PER "2A EXTINGUISHER" 1045 SM
FIRE EXTINGUISHERS SHALL BE CABINET MOUNTED, IN FINISHED AREAS, AND BRACKET MOUNTED IN UNFINISHED AREAS WITH A MAXIMUM PERMISSIBLE MOUNTING HEIGHT TO TOP OF EXTINGUISHER OF 1372 MM AND SHALL NOT PROJECT FROM THE WALL MORE THAN 100 MM
INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS OR AISLES (ADA 4.2.6 & 4.4.1)
ALL EXTINGUISHERS SHALL BE GOVERNMENT FURNISHED GOVERNMENT INSTALLED.
INTERIOR FINISHES: NFPA 101
INTERIOR WALL AND CEILING FINISH MATERIALS:
CLASS A, B, OR C IN ALL SPACES EXCEPT EXIT ENCLOSURES TABLE A10.2.2, NOTE 6
INTERIOR FLOOR MATERIALS:
CLASS I OR II, IN CORRIDORS AND EXITS: TABLE A10.2.2, NOTE 6
FIRE SPRINKLER SYSTEM PROTECTION:
NOT REQUIRED PER UFC 3-600-01, BUT REQUIRED PER UFC 4-214-02.
FIRE ALARM SYSTEM PROTECTION:
REQUIRED PER UFC 3-600-01, AND UFC 4-214-02.
MASS NOTIFICATION SYSTEM:
NOT REQUIRED PER UFC 4-010-01: FOR INHABITED BUILDINGS, LOW OCCUPANCY BUILDING WITH LESS THAN 11 DOD PERSONNEL.
UNITED FACILITIES CRITERIA:
UFC 1-200-01 DESIGN: GENERAL BUILDING REQUIREMENTS, 19 JULY 2011
UFC 3-460-01 DESIGN; PETROLEUM FUEL FACILITIES, 16 AUGUST 2010
UFC 3-600-01 DESIGN: FIRE PROTECTION ENGINEERING FOR FACILITIES, 14 JULY 2009
UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 2 FEBRUARY 2012
UFC 4-214-02 TACTICAL EQUIPMENT MAINTENANCE FACILITIES (TEMF) STANDARD DESIGN 17 MARCH 2011
OTHER DOD DESIGN STANDARDS:
TI-800-01 TECHNICAL INSTRUCTIONS, DESIGN CRITERIA, 20 JULY 1998
SAGAMI GENERAL DEPOT ARMY INSTALLATION DESIGN GUIDE, JULY 2005
APPLICABLE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODES:
NFPA 1 FIRE CODE, 2009
NFPA 10 PORTABLE FIRE EXTINGUISHERS, 2010
NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS, 2010
NFPA 20 INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION, 2010
NFPA 24 INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES, 2010
NFPA 30 FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE, 2012
NFPA 70 NATIONAL ELECTRICAL CODE, 2011
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, 2010
NFPA 90A INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2012
NFPA 90B INSTALLATION OF WARM AIR HEATING AND AIR-CONDITIONING SYSTEMS, 2012
NFPA 101 LIFE SAFETY CODE, 2012
NFPA 291 FIRE FLOW TESTING AND MARKING OF HYDRANTS, 2010
APPLICABLE BUILDING CODES:
IBC INTERNATIONAL BUILDING CODE, 2009 (AS AMENDED BY UFC 1-200-01 REQUIREMENTS)
ACCESSIBILITY STANDARDS AND GUIDELINES:
A) DOD POLICY MEMORANDUM, OCTOBER 31, 2008, SUBJECT: ACCESS FOR PEOPLE WITH DISABILITIES.
B) ARCHITECTURAL BARRIERS ACT STANDARD FOR DEPARTMENT OF DEFENSE FACILITIES.
LOCAL DESIGN STANDARD:
JAPAN ENVIRONMENTAL GOVERNING STANDARDS, NOVEMBER 2010
CONFLICTS IN DESIGN CRITERIA:
WHEN A CONFLICT BETWEEN THE ABOVE LISTED ORGANIZATION STANDARDS EXISTS, THE PROVISIONS OF UFC SHALL TAKE PRECEDENCE
OVER ANY OTHER DOCUMENT OR STANDARD.
GENERAL BUILDING DESCRIPTION:
ORGANIZATIONAL STORAGE BUILDING (OSB) WILL BE PROTECTED BY OVERHEAD WET FIRE SUPPRESSION SYSTEM; AND THROUGHOUT, BY
AN ADDRESSABLE FIRE ALARM SYSTEM.
TYPES OF CONSTRUCTION:
TYPE IIB, NONCOMBUSTIBLE / TYPE II (000) IBC TABLE 601 / NFPA 220 TABLE 4.1.1.
OCCUPANCY CLASSIFICATION:
THE BUILDING WILL CONTAIN A SINGLE OCCUPANCY:
MODERATE-HAZARD STORAGE GROUP S-1/NEW STORAGE: IBC 311 / NFPA 1016.1.13.
BUILDING AREA LIMITATIONS:
STORAGE S-1 ONE STORY WITH 18.3 M SURROUNDED BLDG: AREA IS TO BE UNLIMITED: IBC 5.7.3
TOTAL BUILDING AREA PROVIDED: 342.2 SM (ACTUAL DESIGN). THE AREA OF THE BUILDING COMPLIES S-1 REQUIREMENTS.
ALLOWABLE BUILDING HEIGHT:
THE BASIC ALLOWABLE HEIGHT IS 16.8 M, AND MAXIMUM NUMBER OF STORIES: 2: IBC, TABLE 503.
THE BUILDING IS SINGLE-STORY AND 4.6 M HIGH (ACTUAL DESIGN). THE HEIGHT AND NUMBER OF STORIES OF THE BUILDING COMPLIES S-1
REQUIREMENTS.
TYPE OF CONSTRUCTION:
FIRE RESISTIVE RATING REQUIREMENTS FOR BUILDING ELEMENTS:
UNPROTECTED, NON-COMBUSTIBLE, TYPE IIB , TYPE II (000)
STRUCTURAL FRAME IBC NFPA 101
(INCLUDING COLUMNS, GIRDERS, AND TRUSSES) TABLE 601 TABLE A 8.2.1.2
BEARING WALLS - EXTERIOR 0 HR 0 HR
BEARING WALLS - INTERIOR 0 HR 0 HR
NONBEARING WALLS & PARTITIONS - EXTERIOR* 0 HR 0 HR
NONBEARING WALLS & PARTITIONS - INTERIOR 0 HR 0 HR
FLOOR CONSTRUCTION (INCLUDING SUPPORTING BEAMS & JOISTS 0 HR 0 HR
ROOF CONSTRUCTION (INCLUDING SUPPORTING BEAMS & JOISTS) 0 HR 0 HR
*ALL EXTERIOR WALLS OF THE BUILDING ARE PROVIDED WITH A MINIMUM 3 M FIRE SEPARATION DISTANCE AND ARE NOT REQUIRED TO HAVE A FIRE-RESISTANCE RATING (IBC, TABLE 602). THE EXTERIOR WALLS ARE ALLOWED TO HAVE UNLIMITED UNPROTECTED OPENINGS
(IBC, 705.8.1 EXCEPTION 2).
OCCUPANT LOAD FACTORS: NFPA 101 TABLE 7.3.1.2
ALL FACTORS ARE EXPRESSED IN GROSS AREA UNLESS MARKED "NET": NFPA 101 TABLE 7.3.1.2 (a)
STORAGE (S-1) = 46.5 SM / PERSON
MEANS OF EGRESS REQUIREMENTS:
EGRESS WIDTH PER PERSON SERVED:
LEVEL COMPONENTS & RAMPS: 5 MM/PERSON NFPA 101 TABLE 7.3.3.1
DOOR WIDTHS
• MINIMUM: 915 MM NFPA 101 7.3.4.1 (2)
LIFE SAFETY CODE ANALYSIS
US ARMY CORPS
OF ENGINEERS
JAPAN ENGINEER DISTRICT
A
D A
T E
D
E S
IG
N
E D
B Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
T
R
IC
T , J
A P
A N
C O
R P
S O
F E
N G
IN
E
E R
S A
P O
A P
-5
Sheet Reference Number:
LE
ID
O S
E N
G
IN
E E
R
IN
G , L
LC
N
. B R
O A
D W
A Y
, S U
IT
E
O K
LA
H
O M
A C
IT
Y
, O K
5-
8-w w w
.L E
ID
O
S .c om /e ng in ee rin g
B C D E F G H
S C
A
LE
D R
A W
IN
G
C O
D E
A1 Size 594mm x 841mm
P R
O
JE
C T
E N
G
IN
E E
R /A
R C
H
IT
E C
T
E
N O
D
ES
C
R
IP
TI
O
N D
AT
E
AP
R
A B C D E F G H
SA
G
AM
I G
EN
ER
AL
D
EP
O
T, J
AP
AN
TA
C
T I C
AL
E
Q U
IP
M
E N T
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
JU
L
JU
L
As in di ca te d
GI001
PQ
C
ZN
P
R C
R
TS
W
FY
1 3
M C
A
PN
O
SB
P O
L/ H
AZ
M
AT
(V
O
LU
M E
O
F 4)
LI
F
E S
A F
E T
Y C
O D
E S
A N
A
LY
S
IS
A N
D F
LO
O
R P
LA
N
SCALE 1 : 100
LIFE SAFETY FLOOR PLAN1
SCALE - 1:100
0 400020001000
PLAN
NORTH
N O
D
ES
C
R
IP
TI
O
N D
AT
E
AP
R
R T
A
7/
2/
O S
B
P
L
H
A Z
M A
T
B
U I L
D I N
G
V
O L
U M
E
F
US ARMY CORPS OF ENGINEERS
JAPAN ENGINEER DISTRICT
A
D A
T E
D
E S
I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
J A
P A
N
C O
R P
S
O
F
E
N G
I N
E E
R S
A P
O
A
P
Sheet
Reference
Number:
B C D E F G H
S C
A L
E
D R
A W
I N
G
C
O D
E
A B C D E F G H
A1 Size 594mm x 841mm
P R
O J E
C
N G
I N
E E
R A
R C
H I T
E C
T
E
J U
L
J U
L
REDUNDANCY SHALL BE PROVIDED TO THE VERTICAL AND HORIZONTAL BRACING SYSTEMS3.
EITHER BY USING MULTIPLE BAYS OF TENSION ONLY X-BRACING MEMBERS OR BY USING
BRACING MEMBERS THAT ARE CAPABLE OF BOTH TENSION AND COMPRESSION IF BRACING
IS PLACED IN A SINGLE BAY.
THE STANDING SEAM ROOFING SHALL NOT BE PERMITTED TO ACT AS A DIAPHRAGM TO4.
TRANSFER THE LATERAL LOADS.
ALL BRACING USED TO TRANSFER OR RESIST LOADS SHALL BE EITHER HOT ROLLED STEEL5.
SECTIONS OR RODS. CABLE BRACING IS NOT ALLOWED, EXCEPT FOR ERECTION PURPOSES.
CONTRACTOR SHALL COORDINATE THE COLUMN ANCHOR BOLT LAYOUT WITH THE 6.
METAL BUILDING SYSTEM MANUFACTURER. AT LEAST FOUR (4) ANCHOR BOLTS ARE
REQUIRED FOR COLUMN BASE PLATES UNO. ANCHOR BOLTS SHALL NOT BE LESS THAN 19 MM
NOMINAL SIZE. ANCHOR BOLTS SHALL BE DESIGNED BY THE METAL BUILDING SYSTEM
SUPPLIER. COLUMN ANCHOR BOLTS SHALL BE POSITIVELY LOCATED USING 3 MM SHEET
METAL TEMPLATES FOR ALL COLUMN BASE PLATES. BASE PLATES TEMPLATE ANCHOR BOLT
HOLES SHALL NOT EXCEED BOLT DIS ± 1.6 MM. PROVISION SHALL BE MADE FOR ALL ANCHOR
BOLTS TO BE RIGIDLY HELD IN POSITION TO PREVENT MOVEMENT DURING CONCRETE
PLACEMENT. ANCHOR BOLTS SHALL NOT BE TIGHTENED PRIOR TO 14 DAYS FOLLOWING
CONCRETE PLACEMENT.
REFER TO SECTION 13 34 19 OF THE CONTRACT SPECIFICATION FOR ADDITIONAL METAL7.
BUILDING SYSTEM REQUIREMENTS.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING BUILDING MANUFACTURER THE MAGNITUDE8.
AND APPROXIMATE LOCATIONS OF ALL CONCERNED HANGER LOADS GREATER THAN 25 KG.
REFER TO ALL MECHANICAL SHEETS FOR PIPE AND HVAC ROUTING AND SIZES.
CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND COORDINATION OF ALL LOAD9.
SUPPORT SYSTEMS. THE CONTRACTOR SHALL ACCOUNT FOR ALL LOADS IMPOSED ON ALL
SUPPORT SYSTEMS MEMBERS AND THEIR CONNECTION INCLUDING BUT NOT LIMITED TO ALL
COLLATERAL AND CONCENTRATED LOADS. DESIGN AND PROVIDE STRUCTURAL MEMBERS
FOR SUPPORT OF HVAC UNITS, DUCTS, FANS, PIPING, ELECTRICAL COMPONENTS,
SUPPORTED PARTITIONS, ETC.
THE MBS MANUFACTURER IS RESPONSIBLE FOR PROVIDING DOOR AND WINDOW-TO-BUILDING 10.
SUB-FRAMING AND CONNECTIONS TO FRAME MEMBERS WHICH MEET THE REQUIREMENTS OF
UFC 4-010-01 "DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS" AND UFC 4-010-02
"DOD ANTITERRORISM STANDOFF DISTANCE FOR BUILDINGS" DATED 9 FEBRUARY 2012
ANY CORRESPONDING DESIGN IS THE RESPONSIBILITY OF THE MBS MANUFACTURER.
COORDINATE WINDOW LOADS AND ANCHORAGE REQUIREMENTS WITH GENERAL CONTRACTOR.
THE METAL BUILDING SYSTEM SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE11.
METAL BUILDING MANUFACTURER'S ASSOCIATION (MBMA), DESIGN PRACTICES MANUAL.
FLANGE BRACING AT MBS COLUMN IS NOT PERMITTED.12.
DESIGN LOADS
LIVE LOADS2.
1.00 KN/MROOF LIVE LOADS, (REDUCTION ALLOWED)a.
SNOW LOAD3.
EXPOSURE CATEGORY C
GROUND SNOW LOAD
b.
a.
WIND LOAD4.
161 KM/HR
EXPOSURE CATEGORY C
WIND SPEED
b.
a.
SEISMIC LOAD5.
= 1.87 S S d.
c. S
= 0.75
Ig. = 1.00
Ci. = 0.208, (USE FOR BOTH DIRECTIONS AND FRAME TYPE)
STORAGE ROOMb. 5.98 KN/M
1.00 KN/M 2
S
(20 PSF)
(125 PSF)
(21 PSF)
(100 MPH)
SITE CLASSIFICATION a. CLASS D SEISMIC DESIGN CATEGORYb. CATEGORY E
DEAD LOADS1.
DEAD LOADS ARE BASED ON ASCE/SEI 7-05 MINIMUM DESIGN LOADS FOR
BUILDING AND OTHER STRUCTURES, TABLE C3-1
BUILDING AND OTHER STRUCTURES, IBC 2009, INTERNATIONAL BUILDING CODE,
UFC 3-301-01, STRUCTURAL LOAD DATA, 27 JANUARY 2010 WITH CHANGE 3,
LIVE LOADS ARE BASED ON ASCE/SEI 7-05 MINIMUM DESIGN LOADS FOR
= 1.25 S S f.
e. DS
= 0.75D1
SLAB ON GRADEc. 5.98 KN/M 2 (125 PSF)
METHOD: EQUIVALENT LATERAL LOAD PROCEDURE, BOTH DIRECTIONS
BUILDING AND OTHER STRUCTURES, IBC 2009, INTERNATIONAL BUILDING CODE,
SNOW LOADS ARE BASED ON ASCE/SEI 7- 05 MINIMUM DESIGN LOADS FOR
BUILDING AND OTHER STRUCTURES, IBC 2009, INTERNATIONAL BUILDING CODE,
WIND LOADS ARE BASED ON ASCE/SEI 7-05 MINIMUM DESIGN LOADS FOR
BUILDING AND OTHER STRUCTURES, IBC 2009, INTERNATIONAL BUILDING CODE,
SEISMIC LOADS ARE BASED ON ASCE/SEI 7-05 MINIMUM DESIGN LOADS FOR
ABBREVIATIONS
PILINGG.
PREDRILL PILE HOLES THROUGH FILL, NEW OR EXISTING TO AT LEAST THE ELEVATION OF THE4.
NATURAL GROUND SURFACE OR TO A DEPTH OF 3.00 METERS WHICHEVER IS GREATER.
WITH PRIOR WRITTEN AUTHORIZATION FROM THE CONTRACTING OFFICER, THE CONTRACTOR
MAY PREDRILL HOLES TO GREATER DEPTHS TO MINIMIZE THE EFFECTS OF VIBRATION ON
EXISTING ADJACENT STRUCTURES TO THE WORKS AND/OR OTHER REASONS THE CONTRACTOR
PROPOSES. ACCURATELY DRILL PILE HOLES WITH HOLES CENTERED OVER THE PLAN LOCATION
DRIVE TEST PILES OF THE CROSS SECTION AND TYPE AS THE PERMANENT PILES SHOWN IN 1.
THE PLANS. DRIVE TEST PILES IN THE POSITION OF PERMANENT PILES AT THE DESIGNATED
LOCATIONS. THE LENGTH OF PILES SHOWN IN THE DRAWINGS ARE BASED ON INFORMATIONS
OF THE PILING.
AVAILABLE DURING DESIGN AND ARE APPROXIMATE ONLY, USE 2.00 METER LONGER TEST PILES.
2. AS A MINIMUM THE CONTRACTOR SHALL NOT CEASED DRIVING OF TEST PILES UNTIL OBTAINING
THE REQUIRED BEARING CAPACITY CONTINUOUSLY FOR 3.00 METERS UNLESS REACHING
PRACTICAL REFUSAL FIRST.
3. THE LENGTH OF PILES SHOWN IN THE DRAWINGS ARE BASED ON INFORMATIONS AVAILABLE
DURING DESIGN AND ARE APPROXIMATE ONLY. BEFORE DRIVING THE PERMANENT PILES, THE
CONTRACTOR SHALL DETERMINED THE FINAL PILE LENGTH BASED ON INFORMATIONS GAINED
FROM THE DRIVING THE TEST PILES AND FROM SUPPLEMENTAL SOIL TESTING, ETC.
PILE CAPACITY6.
ANTI-TERRORISM / FORCE PROTECTION LOADS7.
H.
CASE B: LONGITUDINAL DIRECTION
S-001
S A
G A
M I
G
E N
E R
L
P
O T
J A
P A
N
T A
C T
I C
Q U
I P
M E
M
I N
T E
N A
N C
E
F
A C
I L
I T
Y
F Y
P
G E
N E
R A
L
N
O T
S
I G
N
L
O A
D S
31 JANUARY 2012 .
NOT REQUIRED TO MEET THE PROVISION'S OF UFC 4-010-01, 9 FEBRUARY, 2012
DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS.
THE ORGANIZATIONAL STORAGE BUILDING IS A LOW OCCUPANCY BUILDING AND
BB BOTTOM BAR
CNJ CONTROL JOINT
HOR HORIZONTAL
MIN MINIMUM
OC ON CENTER
RC REINFORCED CONCRETE
TB TOP BAR
TOC TOP OF CONCRETE
TOS TOP OF STEEL
TYP TYPICAL
VERT VERTICAL
WP WORK POINT
ETC AND OTHER THINGS
P1,P2, ... FOUNDATION PLAN PEDESTAL NOS. 1, NOS. 2, ...
PC1,PC2, ... PILE CAP NOS. 1, NOS. 2, ...
FB1, FB2, ... FOOTING BEAM NOS. 1, FOOTING BEAM NOS. 2, ...
SQ.M SQUARE METER
LLV LONG LEG VERTICAL
MAX MAXIMUM
FFL FINISH FLOOR LINE
ELEC ELECTRICAL
MECH MECHANICAL
DWGS DRAWINGS
MM MILLIMETER
METHOD 2: ANALYTICAL PROCEDURE
CLR CLEAR
WIND LOAD DIAGRAMSc.
CASE A: TRANSVERSE DIRECTION
WIND DIRECTION
2a
.557
.557 .416
.195
.486 .486
.769 .769
.557
.557
EQUAL
EQUAL
.628
1.106
.380
.540
2a WIND DIRECTION
.200
.769
.491.422
.548 .635
1.106
.388
.557
.557
NOTES:
PRESSURE IN KN/M1.
2.
a 3.
= 1.00 METER
2a = 2.00 METER
MATERIAL STRENGTHS :
D.
DESIGN CODE: AISC STEEL CONSTRUCTION MANUAL (AISC 325-05) 13TH EDITION.1.
SLEEVES, INSERTS, MECHANICAL OPENINGS, CONDUITS, PIPES, RECESSES, DEPRESSIONS17.
CURBS AND OTHER EMBEDDED ITEMS TO BE PROVIDED FOR AS SHOWN ON THE
ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND AS REQUIRED BY
EQUIPMENT MANUFACTURERS. INSTALLATION OF THESE ITEMS TO BE COORDINATED AND
PROVIDED FOR PRIOR TO PLACING CONCRETE.
PROVIDE BLOCK-OUTS AS REQUIRED FOR PRE-CAST CONCRETE PANEL ANCHORAGE.18.
FILL WITH CONCRETE ONCE PANEL IS IN PLACE.
ANCHOR RODS TO BE ASTM F 1554 OR JIS B 1220, FY = 250 MPa MINIMUM, GALVANIZED.19.
20.
STRUCTURAL STEEL
2.
A. STRUCTURAL STEEL ROLLED SHAPES
B. MISCELLANEOUS PLATES AND BAR
C. STRUCTURAL STEEL TUBING
D.. STRUCTURAL STEEL PIPE
E.. CONNECTION BOLTS
F. ANCHOR RODS
G. WELDS (E70XX ELECTRODES)
H. STUD ANCHORS
I. EXPANSION BOLTS
STRUCTURAL STEEL SHALL BE FABRICATED IN ACCORDANCE WITH THE AMERICAN INSTITUTE 3.
OF STEEL CONSTRUCTION (AISC). STEEL ERECTION SHALL BE IN ACCORDANCE WITH THE
REQUIREMENTS OF THE AISC AND THE OSHA STEEL ERECTION STANDARD, 29 CPR APT 1926,
SUBPART R-STEEL ERECTION, EFFECTIVE DATE JANUARY 18, 2002.
STRUCTURAL STEEL, UNO, TO BE NEW STEEL CONFORMING TO THE REQUIREMENTS OF4.
ASTM A 6/ A 6M OR JIS G 3138.
THE STRUCTURAL STEEL FABRICATOR, AND/OR GENERAL CONTRACTOR, MUST VERIFY ALL5.
EXISTING DIMENSIONS AND CONDITIONS AT THE SITE. ALL DISCREPANCIES FOUND ARE TO
BE REPORTED TO THE CONTRACTING OFFICER PRIOR TO PREPARATION OF SHOP DRAWINGS.
SHOP DRAWINGS ARE TO INCLUDE ALL FIELD MEASUREMENTS AND CONDITIONS.
STRUCTURAL STEEL FABRICATOR IS TO PROVIDE FOR VERTICAL AND HORIZONTAL FIELD 6.
ADJUSTMENT OF ALL SUPPORT ASSEMBLIES.
CUTS, HOLES, COPING, ETC. REQUIRED FOR OTHER TRADES MUST BE SHOWN ON THE SHOP 7.
DRAWINGS AND MADE IN THE SHOP. CUTS OR BURNING OF HOLES IN THE FIELD WILL NOT
BE PERMITTED.
ERECTION AIDS SHALL NOT BE VISIBLE IN THE FINISHED CONSTRUCTION UNLESS STEEL IS8.
ALLOWED TO BE EXPOSED. REMOVAL OF ERECTION AIDS FOR ANY REASON SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR.
9.
THAT INCLUDE BUT ARE NOT LIMITED TO: ERECTION ANGLES, LIFT HOLES, ACCESS HOLES
AND OTHER AIDS, WELDING PROCEDURES, REQUIRED ROOT OPENINGS, ROOT FACE
DIMENSIONS, GROOVE ANGLES, BACKING BARS, BACKING RINGS, COPES AND TRANSITION
TAPERS OF UNEQUAL PARTS.
BOLTED CONNECTIONS TO BE MADE ACCORDING TO AISC TABLE II OR III FRAMED BEAM10.
CONNECTIONS. THE MINIMUM DEPTH OF THE CONNECTION MUST BE MORE THAN 75% OF
THE BEAM DEPTH EXCEPT THAT BEAMS FRAMING TO COLUMNS TO HAVE FULL DEPTH
CONNECTIONS USING 10MM MINIMUM CONNECTION ANGLES OR PLATES, COMPRESSIBLE-
WASHER-TYPE DIRECT TENSION INDICATORS OR TWIST-OFF-TYPE TENSION-CONTROL
BOLTS/ NUTS CONFORMING TO RCSC SHALL BE USED.
A: NON-COMPOSITE BEAM CONNECTIONS TO BE DESIGNED FOR ONE HALF THE UNIFORM
LOAD CAPACITY OF THE BEAM AS TABULATED BY AISC UNLESS HIGHER LOADS ARE
INDICATED ON THE DRAWINGS.
UNO, STRUCTURAL STEEL CONNECTIONS TO BE SHOP WELDED AND FIELD BOLTED.11.
SUBSTITUTION OF EXPANSION ANCHORS FOR EMBEDDED ANCHORS SHOWN ON THE 12.
DRAWINGS WILL NOT BE PERMITTED.
WELDING TO BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS)13.
"STRUCTURAL WELDING CODE-ANSI/AWS D1.1/ D1.1M" (LATEST EDITION). USE E70XX
ELECTRODES UNLESS OTHERWISE INDICATED ON THE DRAWINGS.
MANUFACTURE STEEL GRATING IN ACCORDANCE WITH THE "METAL BAR GRATING MANUAL" 14.
AS PUBLISHED BY THE NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURER,
LATEST EDITION. STEEL FOR GRATING TO CONFORM TO ASTM A 1011/A1011M.
STRUCTURAL STEEL TO BE PAINTED PER SPECIFICATIONS, UNO.15.
COLD FORMED LIGHT GAUGE FRAMINGE.
DESIGN CODE: AISC COLD FORMED STEEL MANUAL 1.
STEEL STUDS ARE SPECIFIED USING STANDARD STEEL STUD MANUFACTURERS2.
ASSOCIATION (SSMA) NOMENCLATURE. ALL SHAPES SHALL CONFORM TO STANDARD
SSMA SHAPES. STEEL STUD FLANGES SHALL HAVE A MINIMUM RETURN LIP OF 6MM.
ALL WELDING TO BE DONE WITH CONTINUOUS FEED WIRE ELECTRODES, GAS SHIELDING.3.
ALL WELDING TO BE DONE BY AMERICAN WELDING SOCIETY (AWS) CERTIFIED WELDERS. 4.
MEMBER PROPERTIES USED IN THE DESIGN ARE BASED ON THE CROSS SECTIONAL 5.
DIMENSIONS SHOWN AND MAY NOT BE SUBSTITUTED WITHOUT COMPLETE, CERTIFIED
STRUCTURAL DESIGN CALCULATIONS.
EXPANSION JOINT FILLER AND SEALANT. EXPANSION JOINT FILLER SHALL BE PREFORMED
MATERIAL CONFORMING TO ASTM D 1751 OR ASTM D 1752. UNLESS OTHERWISE INDICATED,
FILLER MATERIAL SHALL BE 10 MM THICK AND OF A WIDTH APPLICABLE FOR THE JOINT FORMED.
EXPANSION AND CONTRACTION JOINT SEALANT SHALL BE PREFORMED POLYCHLOROPRENE
ELASTOMERIC TYPE ASTM D 2628. JOINT SEALANT SHALL BE APPLIED AS RECOMMENDED
BT THE MANUFACTURER OF THE SEALANT.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ERECTION AIDS AND JOINT PREPARATION
METAL BUILDING SYSTEM (MBS)F.
ANCHOR RODS AND FOUNDATION DIMENSIONS SHOWN ON THE CONTRACT DRAWINGS FOR 1.
THE METAL BUILDING SYSTEMS ARE PRELIMINARY AND FOR BIDDING PURPOSES ONLY.
THE FINAL MBS FOUNDATIONS AND ANCHOR ROD EMBEDMENT SHALL BE DESIGNED BY A
PROFESSIONAL ENGINEER HIRED BY THE CONTRACTOR . THE FINAL DESIGN SHALL BE
BE BASED ON THE SOIL PARAMETERS SPECIFIED IN THE SOIL EXPLORATION REPORT AND
THE FINAL COLUMN REACTIONS REPORTED BY THE MBS MANUFACTURER. THE DESIGN
SHALL BE SIGNED AND SEALED BY THE PROFESSIONAL ENGINEER REGISTERED TO
APPROVAL. FOUNDATIONS FOR ITEMS OTHER THAN THE MBS COLUMN FOUNDATION WILL
BE CONSTRUCTED AS SHOWN IN THE DRAWINGS.
MAXIMUM LATERAL DRIFT OF THE BUILDING'S AND CANOPY'S STEEL FRAMES AT THE2.
EAVES SHALL NOT EXCEED h/240, OR 50 MM. "h" REPRESENTS THE FRAME HEIGHT
FROM THE TOP OF THE BASE PLATE TO THE TOP OF THE EAVE STRUT. THE 0.7 FACTOR
PER IBC TABLE 1604.3 FOOTNOTE "1" SHALL NOT BE USED IN DETERMINING THE LATERAL
DRIFT.
PRACTICE IN THE UNITED STATES AND SUBMITTED TO THE CONTRACTING OFFICER FOR
ASTM A992, GR. 50
ASTM A36
ASTM A500, GR. B
ASTM A53, GR. B
ASTM A325 N
ASTM F1554, GR. 36
AWS D1.1
ASTM A108
GSA: A - A - 1923A
TYPE 4 (304S.STL)
OR
OR
OR
OR
OR
OR
OR
OR
JIS G 3136
JIS G 3444
JIS G 3446
JIS B 1186
JIS B 1220
JIS Z 3212
JIS B 1198
JIS G 3106
445 MPa
320 MPa 240 MPa 660 MPa 250 MPa 480 MPa 235 MPa
250 MPa
S2 SLAB ON GRADE
UFC 3-301-01, STRUCTURAL LOAD DATA, 27 JANUARY 2010 WITH CHANGE 3,
31 JANUARY 2012 .
UFC 3-301-01, STRUCTURAL LOAD DATA, 27 JANUARY 2010 WITH CHANGE 3,
31 JANUARY 2012 .
UFC 3-301-01, STRUCTURAL LOAD DATA, 27 JANUARY 2010 WITH CHANGE 3,
31 JANUARY 2012 .
JU
L 2
C CENTER LINEL
R = 8, STEEL SPECIAL MOMENT FRAME.
Rh. = 6, SPECIAL STEEL CONCENTRICALLY BRACED FRAME.
(LONGITUDINAL AND TRANSVERSE END WALLS)
(INTERIOR TRANSVERSE FRAMES)
GENERAL NOTESA.
METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY 1.
OF THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING AND
IMPLEMENTING THE NECESSARY PRECAUTIONS TO MAINTAIN AND ENSURE THE INTEGRITY
OF THE STRUCTURE AT ALL STAGES OF CONSTRUCTION.
TEMPORARY BRACING, SHEETING, SHORING, ETC., REQUIRED TO ENSURE THE STRUCTURAL2.
INTEGRITY/STABILITY OF THE EXISTING BUILDINGS, SIDEWALKS, UTILITIES, ETC., DURING
CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE DESIGNED BY
REGISTERED PROFESSIONAL ENGINEER EMPLOYED BY THE CONTRACTOR.
IMPLEMENTATION OF JOB SITE SAFETY IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.3.
SLEEVES OR BLOCK-OUTS REQUIRED FOR PASSAGE OF DUCTWORK, PIPING, DRAINS, 4.
CONDUITS, ETC., IN ADDITION TO ANCHORS AND HANGERS REQUIRED FOR EQUIPMENT AND
PIPING AND UNDER-SLAB UTILITIES ARE NOT SPECIFICALLY, NOR GENERALLY, INDICATED
ON THE STRUCTURAL DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING
SUCH REQUIREMENTS PRIOR TO FABRICATION OR ERECTION OF THE STRUCTURE.
PENETRATIONS ARE SUBJECT TO APPROVAL BY THE CONTRACTING OFFICER.
DIMENSIONS AND INSTALLATION DETAILS OF PURCHASED EQUIPMENT MUST BE VERIFIED
AND COORDINATED WITH THE SUPPORTING STRUCTURE. THE CONTRACTOR IS RESPONSIBLE
FOR DETERMINING SUCH REQUIREMENTS FROM SUBCONTRACTORS AND EQUIPMENT
SUPPLIERS ALONG WITH COORDINATING THE LOCATIONS AND DETAILS FOR THESE ITEMS
PRIOR TO FABRICATION OR ERECTION OF THE SUPPORTING STRUCTURE. ANY CONFLICTS
BETWEEN THESE ITEMS AND THE BUILDING STRUCTURE IS TO BE BROUGHT TO THE
ATTENTION OF THE CONTRACTING OFFICER FOR RESOLUTION.
5.
THE STRUCTURAL DRAWINGS GOVERN THE WORK FOR STRUCTURAL FEATURES, UNLESS 6.
OTHERWISE NOTED. DIMENSIONS SHOWN ON PLANS AND DETAILS ARE TO GOVERN THE
STRUCTURAL WORK.
IN CASE OF CONFLICT BETWEEN THE GENERAL NOTES, SPECIFICATIONS, AND DRAWINGS, 7.
NOTIFY CONTRACTING OFFICER. THE MOST STRINGENT REQUIREMENTS SHALL GOVERN
UNLESS OTHERWISE DIRECTED BY CONTRACTING OFFICER.
WORK NOT INDICATED ON A PART OF THE DRAWINGS, BUT REASONABLY IMPLIED TO BE 8.
SIMILAR TO THAT SHOWN AT CORRESPONDING LOCATIONS, IS TO BE REPEATED.
FOUNDATIONS ARE TO BE PLACED ON UNDISTURBED SOIL OR COMPACTED FILL SOIL2.
CONFORMING TO THE SPECIFICATIONS (MAXIMUM FILL LIFT = 200MM).
ELEVATIONS SHOWN ON THE DRAWINGS AT WHICH FOUNDATIONS BEAR ARE APPROXIMATE
AND MAY VARY TO SUIT SUBSURFACE SOIL CONDITIONS. STEP-IN FOOTING LOCATIONS
SHOWN ON THE DRAWINGS ARE TO BE FIELD VERIFIED AND ADJUSTED AS REQUIRED
SO THAT FOUNDATIONS BEAR ON MATERIAL OF AT LEAST THE CAPACITY NOTED UNDER
DESIGN CRITERIA. ALL EXTERIOR FOOTINGS ARE TO BEAR A MINIMUM OF 450 MM BELOW
FINISHED GRADE.
3.
PRIOR TO PLACING CONCRETE, ANY WATER PRESENT IS TO BE PUMPED OUT FROM THE4.
BOTTOM OF EXCAVATIONS TO A LEVEL APPROVED BY THE CONTRACTING OFFICER.
CONCRETE SLAB ON GRADE HAVE BEEN DESIGNED TO BEAR ON PROPERLY COMPACTED
SUB-GRADE SOILS AS PER THE DESIGN CRITERIA. THE SUB-BASE MATERIAL BENEATH THE
SLAB-ON-GRADE IS TO CONFORM TO ASTM D 1241, TYPE 1, GRADATION B AND BE
COMPACTED IN ACCORDANCE WITH 95% STANDARD DENSITY PER ASTM D 1557
5.
NO BACKFILLING AGAINST WALLS IS TO BE DONE UNTIL THE SLABS AT THE TOP AND
BOTTOM HAVE BEEN PLACED OR ADEQUATE SHORING HAS BEEN PROVIDED. WALLS AND
GRADE BEAMS HAVING BACKFILL AGAINST BOTH SIDES ARE TO HAVE BACKFILL PLACED
ON BOTH SIDES SIMULTANEOUSLY.
6.
OPERABLE EQUIPMENT WITH WEIGHT GREATER THAN DESIGN SURCHARGE MUST MAINTAIN
A SAFE HORIZONTAL CLEAR DISTANCE FROM BASEMENT AND RETAINING WALLS. A SAFE
HORIZONTAL CLEAR DISTANCE IS DEFINED AS THE DISTANCE FROM THE BASE OF THE
RETAINING WALL TO THE TOP OF FINISHED GRADE. DESIGN SURCHARGE EQUALS 488 KG/M .
7.
COORDINATE SLAB ON GRADE PENETRATIONS AND MECH/ELEC REQUIREMENTS WITH8.
MECH/ELEC/PLUMBING SHEETS.
FOOTINGS SHALL BE CONCENTRIC WITH BASE OF COLUMN. SEE DETAILS FOR OFFSETS 9.
WHERE THEY OCCUR UNO.
REINFORCED CONCRETEC.
REINFORCED CONCRETE WORK IS TO BE IN ACCORDANCE WITH THE AMERICAN CONCRETE1.
INSTITUTE (ACI) ACI 318-08, "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE".
MIXING, TRANSPORTING, PLACING AND TESTING OF CONCRETE IS TO BE DONE IN 2.
ACCORDANCE WITH ACI 301.
ALL CAST-IN-PLACE CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH3.
OF 28 MPa . FOR SLAB ON GRADE USE 34 MPa .
THE SLUMP AT POINT OF PLACEMENT IS NOT TO EXCEED 100 MM +/- 25 MM AND THE 4.
WATER/CEMENT RATIO IS NOT TO EXCEED 0.45. IF ADDITIONAL SLUMP (UP TO 200 MM) IS
DESIRED FOR PUMPING A SUPER-PLASTICIZER ADMIXTURE MAY BE ADDED.
AIR ENTRAINMENT: 5% TO 7% IN CONCRETE EXPOSED TO FREEZE/THAW. CONCRETE TO5.
BE NORMAL WEIGHT CONCRETE (2,403 KG/M ) WITH CEMENT CONFORMING TO ASTM 150,
6.
REINFORCEMENT IS TO BE DETAILED, FABRICATED, AND PLACED IN ACCORDANCE WITH7.
THE ACI "DETAILING MANUAL (SP-66)" (LATEST EDITION).
PROVIDE ADEQUATE CONCRETE COVER IN ACCORDANCE WITH REQUIREMENTS AS SET 8.
FORTH BY ACI 318.
REINFORCEMENT IS TO BE SECURELY HELD IN PLACE WHILE PLACING CONCRETE, IF 9.
REQUIRED, ADDITIONAL BARS, STIRRUPS, OR CHAIRS WILL BE FURNISHED SUPPORT
TO KEEP REINFORCEMENT IN PLACE PER DESIGN.
CONTINUOUS REINFORCING BARS TO BE TURNED AND LAPPED AT CORNERS AND INTER-10.
SECTIONS OF WALLS AND FOOTINGS. LAP SPLICES TO BE CLASS B TENSION SPLICES
PER ACI 318. HOOKED BARS TO HAVE STANDARD ACI HOOKS UNO.
CONTINUOUS TOP BARS TO BE SPLICES AT MID-SPAN. CONTINUOUS BOTTOM BARS TO BE11.
SPLICED AT CENTERLINE SUPPORTS (OR AS SHOWN ON DETAILS).
THE LENGTH TO WIDTH RATIO OF SINGLE SLAB POUR IS NOT TO EXCEED 1.5 WITHOUT12.
INTERMEDIATE SAWCUT. CONTROL JOINTS TO BE MADE WITHIN 24 HOURS OF SLAB POURS.
SLAB JOINTS TO BE LOCATED AND SPACED AS SHOWN ON THE DRAWINGS SLABS TO BE
POURED ON AN 0.254 MM POLYETHYLENE VAPOR BARRIER AND A 150 MM CAPILLARY WATER
BARRIER CONFORMING TO ASTM C33 OR JIS A 5005.
CONCRETE SLABS TO BE CURED BY METHOD COMPATIBLE WITH SPECIFIED FLOOR FINISH.13.
WHERE ACCEPTABLE USE A LIQUID MEMEBRANE-CURING COMPOUND AT THE
MANUFACTURER'S RECOMMENDED COVERAGE. SAW JOINTS TO BE CUT AS SOON AS
POSSIBLE WITHOUT RAVELLING THE SURFACE.
SLAB-ON-GRADE CONSTRUCTION JOINTS TO BE PLACED ON COLUMN CENTERLINES. 14.
CONTROL JOINTS TO BE PLACED AT EQUAL INTERVALS IN EACH DIRECTION AS INDICATED
ON THE PLANS. ADAPT CONTROL JOINT LOCATION AT ODD BAYS.
FOUNDATIONSB.
1.
LEVELING GROUT TO BE NON-SHRINK, NON-METALLIC TYPE, FACTORY PREMIXED GROUT 15.
IN ACCORDANCE WITH ASTM C 1107, HAVING A MINIMUM COMPRESSIVE STRENGTH OF NOT
LESS THAN 35 MPa.
(MAXIMUM FILL LIFT = 200 MM ).
PROVIDE FINISHED SLAB-ON-GRADE WITH OVERALL VALUES OF FLATNESS F(F) = 35 AND 16.
LEVELNESS F(L) = 25 ALONG WITH LOCAL VALUE OF FLATNESS F(S) = 24 AND LEVELNESS
F(L) = 17.
DEFORMED REINFORCEMENT SHALL CONFORM TO ASTM A 615/615M : FOR D10 TO D16
GRADE 40 OR JIS G3112 (SD295) AND D19 OR LARGER, GRADE 60 OR JIS G3112 (SD345).
TYPE 1. STEEL TROWEL FINISH SHALL NOT BE APPLIED.
FOUNDATIONS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH CRITERIA ESTABLISHED
BY THE FINAL GEOTECHNICAL REPORT ; DATED JULY 2014 ; SURVEY
ORGANIZATION: UNIVERSAL ENGINEERING CO. LTD.
FOR 350 MMØ X 15.00 METER LONG PILE PER GEOTECHNICAL REPORT
NUMBER : N001 ; SURVEY DATE : APRIL 2012 ; SURVEY ORGANIZATION :
ALLOWABLE PILE BEARING CAPACITY SHALL BE 30.00 TONS (294 KN)
UNIVERSAL ENGINEERING CO.LTD.
L E
I D
G
I N
E E
R I N
G
L
L C
B
R O
A D
W A
Y
S
U I T
E
O K
L A
H O
I T
Y
O
K w w w L
E I D
O S c o m e n g i n e e r i n g
DE
SC
RI
PT
IO
N
DA
TE
AP
R
SY
MB
OL
SY
MB
OL
SY
MB
OL
DA
TE
AP
R R
T A
J U
L
D A
T E
D
E S
I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
J A
P A
N
C O
R P
S
O
F
E
N G
I N
E E
R S
A P
O
A
P
Sheet
Reference
Number:
B C D E F G H
S C
A L E
D R
A W
I N
G
C
O D
E
A B C D E F G H
A1 Size 594mm x 841mm
P R
O J E
G
I N
E E
R A
R C
H I T
E C
T
D A
T E
180° HOOKS
END HOOKS
D16 D19 D22
D25
D10
D13
90° HOOKS
STANDARD HOOK 180°
OR 60 MM MIN.
4d A OR G
BAR BEND 90°
A OR G J A OR G
BAR SIZE
JIS
HOOK
b
D
DETAILING
DIMENSION
D
A
OR
G d
DETAILING
DIMENSION
D = FINISHED INSIDE BEND DIAMETER
d = NOMINAL BAR DIAMETERb
D = 6d FOR D10 THROUGH D25b
J D
(MM)
(MM) (MM) (MM)
db b db
1 TYPICAL REBAR BENDING
SCALE : NOT TO SCALE
4-D13
OPENING
(2 LAYERS)
4-D13
(2 LAYERS)
300 < D < 500
2X4-D16
(2 LAYERS)
2X4-D16
(2 LAYERS)
OPENING OPENING
OPENING
D > 500
N1 B
AR
S
N2 BARS
N2
BARS, BOTH SIDE
N1
BARS, BOTH SIDE
N1 AND N2 BARS SHALL
BE SAME SIZE AS THE
INTERRUPTED MAIN BARS
NOTE:
IN
TE
RR
UP
TE
D
4X2-D16 DIAGONAL
BARS (TB AND BB)
OF OPENING
OF OPENING
(D)
OPENING
D D
D 50D
Ld
(TYP)
(TYP)
D < 300
(TYP)
(T
YP
Ld
3 TYPICAL WALL AND SLAB OPENING
SCALE : NOT TO SCALE
US ARMY CORPS OF ENGINEERS
JAPAN ENGINEER DISTRICT
BAR SIZE
JIS
D10 D13 D16 D19 D22 D25
CLASS A
(MM) (INCH)
19.42 23.31 31.07 36.90 53.41 60.69
1.0 x Ld
CLASS B
(MM) (INCH)
25.25 30.30 40.40 47.97 69.43 78.90
1.3 x Ld
LAP SPLICE
SPLICE
(SEE TABLE)
CLASS A
(MM) (INCH)
14.92 17.93 23.90 28.39 41.08 46.69
1.0 x Ld
CLASS B
(MM) (INCH)
19.42 23.31 31.07 36.90 53.41 60.69
1.3 x Ld
TOP BARS OTHERS
MAIN BAR
SPLICE
(SEE TABLE)
(MIN)
MAIN BAR
TENSION TENSION
(MM) (INCH)
19.42 23.31 31.07 36.90 53.41 60.69
Ldc
LAP SPLICE
IN TENSION IN COMPRESSION
ALL BARS
6d FOR D10, D13, D16b 12d FOR D19, D22, D25b
D
D db A OR G
BEAM
90°
CL
DE
TA
ILI
NG
DI
ME
NS
IO
N
BEAM
CL
DE
TA
ILI
NG
DI
ME
NS
IO
N
D
HO
OK
A
OR
G db
6db
H
D
135°
D = DIMENSION IS BEND DIAMETER
135° HOOKS
STIRRUP HOOKS
D16 D19 D22
D25
D10
D13
90° HOOKS
A OR G H A OR G
BAR SIZE
JIS D
(MM)
(MM) (MM) (MM)
D = BEND DIAMETER
BEAM
CL
DE
TA
ILI
NG
DI
ME
NS
IO
N
D
HO
OK
A
OR
G db
6db
H
D
135°
75 MM MIN.
135° HOOKS
SEISMIC STIRRUP/TIE
D16 D19 D22
D25
D10
D13
A OR G H
BAR SIZE
JIS D
(MM)
(MM) (MM)
D = BEND DIAMETER
H = DIMENSION IS APPROXIMATE D = DIMENSION IS BEND DIAMETER H = DIMENSION IS APPROXIMATE
S-002
T Y
P I C
A L
D
E T
A I L S
Ld = DEVELOPMENT LENGTH Ldc = DEVELOPMENT LENGTH IN COMPRESSION
JU
LY
JU
LY
L E
I D
G
I N
E E
R I N
G
L L C
N
B
R O
A D
W A
Y
S
U I T
E
O K
L A
H O
T
Y
O
K w w w L E
I D
O S c o m e n g i n e e r i n g
DE
SC
RI
PT
IO
N
DA
TE
AP
R
SY
MB
OL
SY
MB
OL
SY
MB
OL
DA
TE
AP
R
JU
L 2
1:25
0 0.5 1.0 2.5M1.5 2.0
GRAPHIC SCALE1 MISCELLANEOUS TYPICAL DETAILS
SCALE 1:25
A
D A
T E
D
E S
I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
J A
P A
N
C O
R P
S
O
F
E
N G
I N
E E
R S
A P
O
A
P
Sheet
Reference
Number:
B C D E F G H
S C
A L E
D R
A W
I N
G
C
O D
E
A B C D E F G H
A1 Size 594mm x 841mm
P R
O J E
G
I N
E E
R A
R C
H I T
E C
T
D A
T E
450 450
PILE CAP PLAN DETAIL, ( PC1 )
SCALE 1:25
ELEVATION / SECTION
450 450
5-D19@200 OC
1,2
1,1
PLAN
US ARMY CORPS OF ENGINEERS
JAPAN ENGINEER DISTRICT
5- D1
9@
0 O C
SCALE 1:25
TYPICAL SLAB ON GRADE
WAINSCOT (WS) DETAILS
SCALE 1:25
90 H
SLAB CONTROL JOINT, ( CNJ )
7575 12
300 300
BOLLARD DETAIL
SCALE 1:25
S2, 150 MM THICK
S1, 250 MM THICK
SLAB CONSTRUCTION JOINT, ( CJ )
H
S-003
M I S
C E
L L
A N
E O
Y P
I C
A L
D
E T
A I L S
0.2 5H
1,5
2,3
C
LR
0 60
0.2 5H
SCALE 1:25 SCALE 1:25
1,2
SCALE 1:25
PEDESTAL DETAILS
SCALE 1:25
SECTION OF P2
650750
425 325
325325
A
SECTION - P1A SECTION - P1B
5±
B
1 6 2 TO 5
0 25
300 400
TYPICAL ELEVATION - "A"
750 (P1A/P1B) 700(P2)
25 LE
VE
LIN
G
GR
OU
T
200200
JU
LY
JU
LY
L E
I D
G
I N
E E
R I N
G
L L C
N
B
R O
A D
W A
Y
S
U I T
E
O K
L A
H O
T
Y
O
K w w w L E
I D
O S c o m e n g i n e e r i n g
DE
SC
RI
PT
IO
N
DA
TE
AP
R
SY
MB
OL
SY
MB
OL
SY
MB
OL
DA
TE
AP
R
JU
L 2
D A
T E
D
E S
I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
J A
P A
N
C O
R P
S
O
F
E
N G
I N
E E
R S
A P
O
A
P
Sheet
Reference
Number:
B C D E F G H
S C
A L E
D R
A W
I N
G
C
O D
E
A B C D E F G H
A1 Size 594mm x 841mm
P R
O J E
G
I N
E E
R A
R C
H I T
E C
T
D A
T E
1 TYPICAL WALL BRACE
NOT TO SCALE
2 TYPICAL ROOF BRACE
NOT TO SCALE
DETAIL 2A DETAIL 2B DETAIL 2C DETAIL 2D
DETAIL E DETAIL F DETAIL G
DETAIL A DETAIL B DETAIL C
ELEVATION
PLAN PLAN
ELEVATION SECTION
ELEVATION
PLAN
ELEVATION SECTION
US ARMY CORPS OF ENGINEERS
JAPAN ENGINEER DISTRICT
S-004
T Y
P I C
A L
B
R A
T
A I L S
TYPICAL WALL BRACE ELEVATION
NOTES:
TYPICAL ROOF BRACE PLAN
NOTES:
JU
LY
JU
LY
L E
I D
G
I N
E E
R I N
G
L L C
N
B
R O
A D
W A
Y
S
U I T
E
O K
L A
H O
T
Y
O
K w w w L E
I D
O S c o m e n g i n e e r i n g
DE
SC
RI
PT
IO
N
DA
TE
AP
R
SY
MB
OL
SY
MB
OL
SY
MB
OL
DA
TE
AP
R
JU
L 2
B
2 3 4 65
6,587 7,112
8,4
35,560
9,1
7,112525 525
A
D A
T E
D
E S
I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
J A
P A
N
C O
R P
S
O
F
E
N G
I N
E E
R S
A P
O
A
P
Sheet
Reference
Number:
B C D E F G H
S C
A L E
D R
A W
I N
G
C
O D
E
A B C D E F G H
A1 Size 594mm x 841mm
P R
O J E
G
I N
E E
R A
R C
H I T
E C
T
D A
T E
1 FOUNDATION PLAN
SCALE 1:100
10 M5420 1
GRAPHIC SCALE
1:100
PLAN
NORTH
2 ROOF FRAMING PLAN
SCALE 1:100
EXTERIOR FACE
OF METAL PANEL
US ARMY CORPS OF ENGINEERS
JAPAN ENGINEER DISTRICT
1 6
A
B
2 3 4 5
6,587 7,112 7,112 6,587
35,360
7,112
P1B,PC1 FB1 FB1 FB1FB1
FB1 FB1 FB1 FB1FB1
FB
FB
CNJ
12MM PREMOLDED
ISOLATION JOINT
FILLER AND SEALANT
FB
FB
FB
(TYPICAL)
P1A,PC1
EXTERIOR FACE
OF METAL PANEL
8,9
8,4
FB
1,248 3,048 965 1,026 2,073 3,048 965 1,026 2,073 3,048 965 1,026 2,073 3,048 965 1,026 1,548 3,048 965 1,026
300 425
1,6
1,625
FB1
P2 P2
3,294 3,556 3,556 3,556 3,556 3,556 3,556 3,294 3,2933,293
4,2
4,2
CNJ
3,294 3,556 3,556 3,556 3,556 3,556 3,556 3,294 3,2933,294
4,2
4,2
4,2
4,2
TOC = 00
S2
(SEE S-003, TYP)
B1 EAVE GIRDERS
B2 MINOR BEAMS
B3
B2
B1
B1
B2
B3
B2
B1
B1
B2
B3
B2
B1
B1 B2
B3
B2
B1
B1
B2
B3
B2
B1
B1
B2
F1 F1 F1 F1 F1 A
CNJ CNJ CNJ
CN
J
CNJ
CN
J
CNJ
CN
J
CNJ
CN
J
CNJ
CN
J
S-101
F O
U N
D A
T I O
N
P
L A
N
A
R
O
F
F
R A
M I N
G
P
L A
N
BRACINGS SEEPURLINS
(TYPICAL)
TEST PILE
(TYP)
7,112 6,587
1,625
B3 RIDGE BEAMS
P1A,PC1
P1A,PC1
P1A,PC1P1B,PC1
P1B,PC1
P1B,PC1
P1B,PC1
P1B,PC1
P1B,PC1
P1B,PC1
F1 A
F1 MOMENT FRAME UNIFORM DEPTH COLUMNS AND GIRDERS
F1A BRACED FRAME, UNIFORM DEPTH COLUMNS AND GIRDERS
JU
LY
JU
LY
L E
I D
G
I N
E E
R I N
G
L L C
N
B
R O
A D
W A
Y
S
U I T
E
O K
L A
H O
T
Y
O
K w w w L E
I D
O S c o m e n g i n e e r i n g
DE
SC
RI
PT
IO
N
DA
TE
AP
R
SY
MB
OL
SY
MB
OL
SY
MB
OL
DA
TE
AP
R
JU
L 2
2,2
2,2
4,2
2,0
1,2
A
D A
T E
D
E S
I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
J A
P A
N
C O
R P
S
O
F
E
N G
I N
E E
R S
A P
O
A
P
Sheet
Reference
Number:
B C D E F G H
S C
A L E
D R
A W
I N
G
C
O D
E
A B C D E F G H
A1 Size 594mm x 841mm
P R
O J E
G
I N
E E
R A
R C
H I T
E C
T
D A
T E
10 M5420 1
GRAPHIC SCALE
1:100
1 WALL ELEVATION AT GRID B
SCALE 1:100
1 2 3 4 5
6,587 7,112 7,112
35,560
7,112425
2 WALL ELEVATION AT GRID A
SCALE 1:100
3 WALL ELEVATION AT GRID 6
SCALE 1:100
4 WALL ELEVATION AT GRID 1
SCALE 1:100
1,2
AB
8,494 225
8,944
4,2
2,0
1,2
3,0
1,2
2256,587 425
3,3
2,2
2,2
4,2
2,0
1,2
A B
8,494 225
8,944
2,1
2,1
US ARMY CORPS OF ENGINEERS
JAPAN ENGINEER DISTRICT
S-201
W A
L L
E
L E
V A
T I O
N S
(TYP)
12345
6,5877,1127,112
35,560
7,112 425
6,587425
(TYP)
(TYP)
2,1
2,1
4,2
2,0
1,2
3,0
1,2
(TYP)
JU
LY
JU
LY
L E
I D
G
I N
E E
R I N
G
L L C
N
B
R O
A D
W A
Y
S
U I T
E
O K
L A
H O
T
Y
O
K w w w L E
I D
O S c o m e n g i n e e r i n g
DE
SC
RI
PT
IO
N
DA
TE
AP
R
SY
MB
OL
SY
MB
OL
SY
MB
OL
DA
TE
AP
R
JU
L 2
1:25
0 0.5 1.0 2.5M1.5 2.0
GRAPHIC SCALE
1 SECTION
SCALE 1:25
A
D A
T E
D
E S
I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
J A
P A
N
C O
R P
S
O
F
E
N G
I N
E E
R S
A P
O
A
P
Sheet
Reference
Number:
B C D E F G H
S C
A L E
D R
A W
I N
G
C
O D
E
A B C D E F G H
A1 Size 594mm x 841mm
P R
O J E
G
I N
E E
R A
R C
H I T
E C
T
D A
T E
8,494225
B A
4,2
2,0
1,2
1,2
3,0
US ARMY CORPS OF ENGINEERS
JAPAN ENGINEER DISTRICT
S-301
S E
C T
I O
N
JU
LY
JU
LY
L E
I D
G
I N
E E
R I N
G
L L C
N
B
R O
A D
W A
Y
S
U I T
E
O K
L A
H O
T
Y
O
K w w w L E
I D
O S c o m e n g i n e e r i n g
DE
SC
RI
PT
IO
N
DA
TE
AP
R
SY
MB
OL
SY
MB
OL
SY
MB
OL
DA
TE
AP
R
JU
L 2
D A
T E
D
E S
I G
N E
D
B
Y
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
J A
P A
N
C O
R P
S
O
F
E
N G
I N
E E
R S
A P
O
A
P
Sheet
Reference
Number:
B C D E F G H
S C
A L E
D R
A W
I N
G
C
O D
E
A B C D E F G H
A1 Size 594mm x 841mm
P R
O J E
G
I N
E E
R A
R C
H I T
E C
T
D A
T E
1 BEAM ELEVATION
SCALE 1:50
1:50
0 1.0 2.0 5M3.0 4.0
GRAPHIC SCALE
US ARMY CORPS OF ENGINEERS
JAPAN ENGINEER DISTRICT
1 2 3
56 4
2,0
1,2
50 400 REST @ 250 OC (MAX) 50400 REST @ 250 OC (MAX) 50400
2,0
1,2
50 400 REST @ 250 OC (MAX) 50400
2,0
1,2
50 400 REST @ 250 OC (MAX) 50400
B A
B A
50 40050 400
S-401
B E
E
V A
T I O
N S
JU
LY
JU
LY
L E
I D
G
I N
E E
R I N
G
L L C
N
B
R O
A D
W A
Y
S
U I T
E
O K
L A
H O
T
Y
O
K w w w L E
I D
O S c o m e n g i n e e r i n g
DE
SC
RI
PT
IO
N
DA
TE
AP
R
SY
MB
OL
SY
MB
OL
SY
MB
OL
DA
TE
AP
R
JU
L 2
AD
ADD
ADDL
ADJ
AFF
AGGR
AL
ALUM
ALT
ANOD
APPROX
ARCH
AREA DRAIN
ADDENDUM
ADDITIONAL
ADJACENT
ABOVE FINISHED FLOOR
AGGREGATE
ACTIVE LEAF
ALUMINUM
ALTERNATE
ANODIZED
APPROXIMATE
ARCHITECTURAL
BD
BETW
BG
BL
BLK
BLKG
BM
BMS
BOT
BRG
BSMT
BU ROD
BUR
BOARD
BETWEEN
BUMPER GUARD
BUILDING LINE
BLOCK
BLOCKING
BEAM
BODY MASS SENSOR
BOTTOM
BEARING
BASEMENT
BACK UP ROD
BUILT-UP ROOF
C TO C
C
CBB
CEM
CER
CF
CG
CIP
CJ
CL
CLG
CMU
COL
COMM
CONC
CONN
CONST
CONT
CONTR
COORD
CS
CSK
CT
CTR
CW
CENTER TO CENTER
COMPACT PARKING SPACE
CONCRETE BACKER BOARD
CEMENT
CERAMIC
CUBIC FOOT
CORNER GUARD
CAST IN PLACE
CONTROL JOINT
CENTER LINE
CEILING
CONCRETE MASONRY UNIT
COLUMN
COMMUNICATIONS
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
COORDINATE
CAST STONE
COUNTER SUNK
CERAMIC TILE
CENTER
CURTAIN WALL
D
DTL
DIA
DIM
DL
DN
DPS
DS
DWG
DWGS
DWLS
DEPTH
DETAIL
DIAMETER
DIMENSION
DEAL LOAD
DOWN
DOOR POSITION SWITCH
DOWN SPOUT
DRAWING
DRAWINGS
DOWELS
E
EB
EXP BLT
EIFS
EJ
EL, ELEV
ELEC
ENCL
EQ
EQUIP
ESC
EVTR
EW
EWC
EXH
EXIST
EXP
EXT
EACH
EXPANSION BOLT
EXPANSION BOLT
EXTERIOR INSULATION FINISH
SYSTEM
EXPANSION JOINT
ELEVATION
ELECTRIC(AL)
ENCLOSE
EQUAL
EQUIPMENT
ESCALATOR
ELEVATOR
EACH WAY
ELECTRICAL WATER COOLER
EXHAUST
EXISTING
EXPOSED
EXTERIOR
FA
FAU
FR
FD
FDN
FE
FEC
FF
FHC
FIN
FIN FLR
FIXT
FLASH
FLR
FLUOR
FO
FT
FTG
FVC
FIRE ALARM
FORCED AIR UNIT
FIRE RESISTIVE
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISHED FLOOR
FIRE HOSE CABINET
FINISH
FINISHED FLOOR
FIXTURE
FLASHING
FLOOR
FLUORESCENT
FACE OF
FOOT
FOOTING
FIRE VALVE CABINET
GA
GALV
GEN
GFRC
GI
GL
GMFG
GND
GR
GRG
GWB
GYP
GYP BD
GAUGE
GALVANIZED
GENERAL
GLASS FIBER REINFORCED CONCRETE
GALVANIZED IRON
GLASS
GLASS MAT FACED GYPSUM BOARD
GROUND
GRADE
GLASS REINFORCED GYPSUM
GYPSUM WALL BOARD
GYPSUM
GYPSUM BOARD
H H/C
HC
HB
HD
HDW
HDWH
HM
HOR
HP
HR
HT
HTR
HIGH
HANDI-CAPPED
HOLLOW CORE
HOSE BIBB
HEAD
HARDWARE
HARDWOOD
HOLLOW METAL
HORIZONTAL
HIGH POINT
HOUR
HEIGHT
HEATER
ID
IN
INSUL
INT
INSIDE DIAMETER
INCH
INSULATION
INTERIOR
JAN
JT
JANITOR
JOINT
K
KO
KP
KSF
KIPS (1,000 LB)
KNOCK OUT
KICK PLATE
KIPS PER SQUARE FOOT
L
LAM
LAV
LB
LF
LG
LIN
LL
LOC
LP
LT
LWC
ANGLE
LAMINATE
LAVATORY
POUND (WEIGHT)
LINEAL FOOT
LONG
LINEAR, LINEAL
LIVE LOAD
LOCATION
LOW POINT
LIGHT
LIGHTWEIGHT CONCRETE
MAS
MATL
MAX
MBM
MBS
MDO
MECH
MEMB
MFR
MIN
MISC
MO
MOD
MOD BIT
MSL
MTD
MTL
MASONRY
MATERIAL
MAXIMUM
METAL BUILDING MANUFACTURER
METAL BUILDING SYSTEM
MEDIUM DENSITY OVERLAY
MECHANICAL
MEMBRANE
MANUFACTURER
MINIM
MISCELLANEOUS
MASONRY OPENING
MODIFIED
MODIFIED BITUMEN
MEAN SEA LEVEL
MOUNTED
METAL
NA
NIC
NO. #
NOM
NTS
NWC
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
NORMAL WEIGHT CONCRETE
O TO O
OA
OC
OBO
OBO - ICS
OD
OD
OFCI
OFOI
OH
OPNG
OPP
OVHD
OUTSIDE TO OUTSIDE
OVER ALL
ON CENTER
OVERSEAS BUILDING OPERATIONS
OVERSEAS BUILDING OPERATIONS
INTERNATIONAL CODE SUPPLEMENTS
OUTSIDE DIAMETER
OVERFLOW DRAIN
OWNER FURNISHED, CONTRACTOR
INSTALLED
OWNER FURNISHED, OWNER
INSTALLED
OPPOSITE HAND
OPENING
OPPOSITE
OVERHEAD
PLAM
PC
PCF
PD
PENT
PERF
PL
PL
PLUMB
PLYWD
PNL
POL
P.O.L.
PORT CEM
PR
PREFAB
PREF
PSF
PSI
PT
PTD
PTN
PLASTIC LAMINATE
PRECAST CONCRETE
POUNDS PER CUBIC FOOT
PLANTER DRAIN
PENTHOUSE
PERFORATED
PROPERTY LINE
PLATE
PLUMBING
PLYWOOD
PANEL
POLISHED
PETROLEUM OIL LUBRICANT
PORTLAND CEMENT
PAIR
PREFABRICATED
PREFINISHED
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POINT
PAINTED
PARTITION
R
RAD
RCP
RD
REBAR
RECP
REF
REINF
RELOC
REQD
RET
REX
RFVC
RM
RO
RWL
RISER
RADIUS
ROOF DRAIN
REINFORCING BAR
REFLECTED CEILING PLAN
RECEPTACLE
REFER OR REFERENCE
REINFORCING
RELOCATE(D)
REQUIRED
RETAINING WALL
REQUEST TO EXIT
RECESSED FIRE VALVE CAB
ROOM
ROUGH OPENING
RAIN WATER LEADER
SAB
SC
SCHED
SECT
SED
SF
SHT
SIM
SMS
SOG
SP
SPA
SPEC
SQ
SS
STA
STC
STD
STIFF
STL
STRUC
SUSP
SYM
SYS
SOUND ATTENUATION BLANKET
SOLID CORE
SCHEDULE
SECTION
STANDARD EMBASSY DESIGN
SQUARE FEET
SHEET
SIMILAR
SHEET METAL SCREW
SLAB ON GRADE
STAND PIPE
SPACE, SPACING
SPECIFICATION
SQUARE
STAINLESS STEEL
STATION
SOUND TRANSMISSION COEFFICIENT
STANDARD
STIFFENER
STEEL
STRUCTURAL
SUSPENDED
SYMMETRICAL
SYSTEM
T T&B
TC
TEL
TEMP
THK
THOLD
TO
TOB
TOC
TOF
TOP
TOS
TO STL
TS
TW
TYP
TREAD
TOP AND BOTTOM
TOP OF CURB
TELEPHONE
TEMPERATURE
THICK
THRESHOLD
TOP OF
TOP BEAM
TOP OF CONCRETE
TOP OF FOOTING
TOP OF PARAPET
TOP OF SLAB
TOP OF STEEL
TUBE STEEL
TOP OF WALL
TYPICAL
UL
UNO
UNDERWRITERS LABORATORIES
UNLESS NOTED OTHERWISE
VAR
VCT
VERT
VEST
VWC
VARIES
VINYL COMPOSITE TILE
VERTICAL
VESTIBULE
VINYL WALL COVERING
W/ W/O W
WD
WDW
WF
WH
WL
WP
WR
WT
WWF
WITH
WITHOUT
WIDTH
WOOD
WINDOW
WIDE FLANGE
WATER HEATER
WIND LOAD
WATERPROOF(ING)
WATER RESISTANT
WEIGHT
WELDED WIRE FABRIC
ABBREVIATIONS
ARCHITECTURAL REFERENCE SYMBOLS:
1t
Room name
101 ROOM NUMBER REFERENCE
KEY NOTE REFERENCE
PARTITION TYPE REFERENCE
DOOR NUMBER REFERENCE
WINDOW REFERENCE
SPOT ELEVATION TAG
1i
US ARMY CORPS
OF ENGINEERS
JAPAN ENGINEER DISTRICT
A
D A
T E
D
E S
IG
N
E D
B Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
T
R
IC
T , J
A P
A N
C O
R P
S O
F E
N G
IN
E
E R
S A
P O
A P
-5
Sheet Reference Number:
LE
ID
O S
E N
G
IN
E E
R
IN
G , L
LC
N
. B R
O A
D W
A Y
, S U
IT
E
O K
LA
H
O M
A C
IT
Y
, O K
5-
8-w w w
.L E
ID
O
S .c om /e ng in ee rin g
B C D E F G H
S C
A
LE
D R
A W
IN
G
C O
D E
A1 Size 594mm x 841mm
P R
O
JE
C T
E N
G
IN
E E
R /A
R C
H
IT
E C
T
E
N O
D
ES
C
R
IP
TI
O
N D
AT
E
AP
R
A B C D E F G H
SA
G
AM
I G
EN
ER
AL
D
EP
O
T, J
AP
AN
TA
C
T I C
AL
E
Q U
IP
M
E N T
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
JU
L
JU
L
A-001
W R
R
M
AN
LC
J
KA
L
FY
1 3
M C
A
PN
O R
G
AN
IZ
A T
IO
N
AL
S
TO
R
AG
E
BU
IL
D
IN
G (V
O
LU
M E
O
F 4)
A R
C H
IT
E
C T
U R
A L
G E
N E
R A
L N
O T
E S
A N
D A
B B
R E
V
IA
T
IO
N S
N O
D
ES
C
R
IP
TI
O
N D
AT
E
AP
R
R T
A
7/
2/
B
2 3 4 5
A-201
A-201
A-201
A-201
A-301
A-301
525 6587 7112 7112 7112 6587 525
A-301
A-301
35560 O.T.O. - FACE OF WALL PANEL
525 1248 3048 965 1026
1773 3048 965 1026
1773 3048 965 1026
1773 3048 965 1026 1248 3048 965 1026
O .T
.O
ORGANIZATIONAL
STORAGE
S100
S100A S100B
S100C S100D
S100E S100F
S100G S100H
S100J S100K
A-501
65 SQ M
(700 SQ FT)
65 SQ M
(700 SQ FT)
65 SQ M
(700 SQ FT)
65 SQ M
(700 SQ FT)
65 SQ M
(700 SQ FT)
TYP.
3702 TYP.TYP.
1 6
A
B
2 3 4 5
A-201
A-201
A-201
A-201
A-301
A-301
A-301
A-301
1:
1:
:1
70 70
1:
1:
:1
RIDGE LINE
GENERAL NOTES
1. ANY DISCREPANCIES IN DIMENSIONS IN THE FIELD SHALL BE
REPORTED FOR DIRECTION PRIOR TO PROCEEDING WITH
CONSTRUCTION.
2. WRITTEN DIMENSIONS GOVERN. DO NOT SCALE DRAWINGS.
3. EXTERIOR WALL DIMENSIONS SHOWN ARE FROM FACE OF
METAL PANEL TO FACE OF CONCRETE, CONCRETE OPENING,
OR BUILDING GRIDLINE.
4. REFER 500 SERIES SHEETS FOR DETAILS.
5. REFERENCE SPECIFICATION SECTION 09 06 90 (COLOR
SCHEDULE) FOR FINISH COLORS/MATERIALS.
WATER FLOW
SNOW CLIP
CROSS MEMBER EXTRUSION
CLAMP (ALUM)
STAINLESS STEEL BOLT & WASHER
PREF STANDING SEAM MTL ROOF PANEL,
AS SPECIFIED
BATTEN
PREF STANDING SEAM MTL ROOF PANEL, AS SPECIFIED
SET SCREWCROSS MEMBER
EXTRUSION
STAINLESS
STEEL BOLT &
WASHER
CLAMP (ALUMINUM)
US ARMY CORPS
OF ENGINEERS
JAPAN ENGINEER DISTRICT
A
D A
T E
D
E S
IG
N
E D
B Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
U .S
. A R
M Y
E N
G
IN
E E
R D
IS
T
R
IC
T , J
A P
A N
C O
R P
S O
F E
N G
IN
E
E R
S A
P O
A P
-5
Sheet Reference Number:
LE
ID
O S
E N
G
IN
E E
R
IN
G , L
LC
N
. B R
O A
D W
A Y
, S U
IT
E
O K
LA
H
O M
A C
IT
Y
, O K
5-
8-w w w
.L E
ID
O
S .c om /e ng in ee rin g
B C D E F G H
S C
A
LE
D R
A W
IN
G
C O
D E
A1 Size 594mm x 841mm
P R
O
JE
C T
E N
G
IN
E E
R /A
R C
H
IT
E C
T
E
N O
D
ES
C
R
IP
TI
O
N D
AT
E
AP
R
A B C D E F G H
SA
G
AM
I G
EN
ER
AL
D
EP
O
T, J
AP
AN
TA
C
T I C
AL
E
Q U
IP
M
E N T
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
JU
L
JU
L
As in di ca te d
A-101
W R
R
M
AN
LC
J
KA
L
FY
1 3
M C
A
PN
O R
G
AN
IZ
A T
IO
N
AL
S
TO
R
AG
E
BU
IL
D
IN
G (V
O
LU
M E
O
F 4)
F
LO
O R
P
LA
N A
N D
R O
O F
P
LA
N
SCALE: 1 : 100
FLOOR PLAN1
SCALE: 1 : 100
ROOF PLAN2
SCALE - 1:100
0 400020001000
SCALE - 1:100
0 400020001000
PLAN
NORTH
PLAN
NORTH
02 PRE-FINISHED METAL (150x150mm) GUTTERS WITH (100mm dia.)
PVC DOWNSPOUTS. PROVIDE CONCRETE SPLASH BLOCK
05 102mm INSULATED METAL ROOF PANEL SYSTEM, R30 09 305mm dia. x 1524mm HIGH, CONCRETE FILLED SCHEDULE 80
GALVANIZED PIPE BOLLARD, PRIME AND PAINT SAFETY
YELLOW, TYP. REFER STRUCTURAL
23 PRE-ENGINEERED STEEL FRAME
37 PRECAST CONCRETE SPLASH BLOCK
68 WIRE MESH SECURITY PARTITION, FULL HEIGHT SLAB TO
STRUCTURE ABOVE
69 SNOW & ICE GUARD
70 TYPICAL GUTTER EXPANSION JOINT
SHEET KEYNOTES
SCALE: NOT TO SCALE
TYP SNOW & ICE GUARD DETAIL3
N O
D
ES
C
R
IP
TI
O
N D
AT
E
AP
R
R T
A
7/
2/
FINISHED FLOOR
EAVE
A-301
05 01
70 70
FINISHED FLOOR
AB
EAVE
A-301
05 01
1:10 1:10
L-1
FINISHED FLOOR
A B
EAVE
A-301
05 01
1:10 1:10
L-2
FINISHED FLOOR
1 6
EAVE
2 3 4 5
A-301
S100A S100B S100C S100D S100E S100F S100G S100H S100J S100K
12 12 12 12
26 26 26 2609 09 09 09 09 09 09 09 09 09 0909 09
METAL WALL PANELS, HARDWARE, AND ASSOCIATED TRIM:
GRAY SAND 13-1010 TPX (JPS T19-75D)
METAL ROOF PANELS AND ROOF CURBS
(EXTERIOR FACE) POLAR WHITE W/ AN SRI INDEX OF
MIN. 78, ADOBE TEXTURE
(INTERIOR FACE) PREFINISHED WHITE
ROOF CURBS, FASCIAS AND GUTTERING
WHITE TO MATCH ROOF
STEEL DOOR AND FRAMES:
CARAFE 19-1116 TPX (JPS T09-30D)
ALUMINUM WINDOWS:
CARAFE…