Libby_Emergency_Sluice_Gate_-_Attachment_A_-_Eval_Criteria.docx

DOCX document 17 KB Posted

Attached to
Emergency Sluice Gate Bulkhead, Libby Dam, Libby, MT Federal contract opportunity
Solicitation number
W912DW19R0016
Issued by
Department of the Army Corps of Engineers Engineering District Seattle

About this file

Word version of Attachment A for Evaluation Criteria

View the file

Other files for this federal contract opportunity

Other files attached to Emergency Sluice Gate Bulkhead, Libby Dam, Libby, MT, newest first.
File Type Posted
Amendment_0003.pdf PDF
Amendment_0002.pdf PDF
W912DW19R0016_Amendment_0001.pdf PDF
Request_for_Visitation_Authority_(RVA).pdf PDF
Libby_Emergency_Sluice_Gate_FINAL_Contract_Drawings.pdf PDF
Libby_Emergency_Sluice_Gate_Reference_Drawings.pdf PDF
W912DW19R0016.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION M - ATTACHMENT A

FACTOR 1: CORPORATE EXPERIENCE AND CAPABILITIES FOR FABRICATION OF HYDRAULIC STEEL GATES PROJECTS

USE ONE FORM PER PROJECT

Note: A separate Word version of this document will be accessible on fedbizopps at fbo.gov

1. Circle to indicate if work was performed as a Prime Contractor or Subcontractor:

FABRICATION OF HYDRAULIC STEEL GATES Prime Subcontractor

2. Name of Offeror: ______________________________________________

3. Project Title: ______________________________________________

4. Contract/Project Number: ______________________________________________

5. Project Location: ______________________________________________

6. Total Contract Value: $ ___________________

7. If Offeror performed as Subcontractor, the $ value of Subcontract: $ ______________

8. Construction Phase Start Date (Month/Year): ____________________________________

9. Construction Phase Completion Date (Month/Year): _______________________________ (Actual date if project has been completed, anticipated date and percent complete if project is not complete)

10. Name and Title of Customer/Client: _____________________________________________

11. Telephone Number of Customer/Client: _________________________________________

12. Email Address of Customer/Client: ____________________________________________

13. Describe General Scope of the Project (designed, built, and installed new major features, rebuilt select components, etc.; focus on fabrication aspects of the project):

14. Describe/demonstrate how the project is relevant to the solicitation in the following areas:

14.1. Describe what type of Hydraulic Steel Structure was welded to AWS D1.5/D1.5M and how it meets criteria of factor A:

14.2. Describe what type of Paint system was provided and how it meets criteria of factor A:

14.3. Describe what type of facility work was performed at:

14.4. Describe the Offeror’s role and responsibility during construction of the project. Indicate what portions of the project were self-performed, what parts were sub-contracted, and who the subcontractors were:

15. Your Performance Evaluation by Customer/Client, if known:

16. Provide at least 1 representative photo of the project.

Note: Use of additional pages as necessary to provide sufficient detail to satisfy Section M. However, information provided outside of this form will not be considered for Factor A

File details come from the government source that posted it.